Loading...
HomeMy WebLinkAboutADOBE SPRINGS 73555-INDB19-0010_PLANSe VICINITY MAP CITY OF PALM DESERT NOTES CONSTRUCTION WORK HOURS - OCTOBER 1ST TO APRIL 30TH MONDAY - FRIDAY SATURDAY SUNDAY GOVERNMENT CODE HOLIDAYS CONSTRUCTION WORK HOURS - MAY 1 ST THROUGH SEPTEMBER 30TH MONDAY - FRIDAY SATURDAY SUNDAY GOVERNMENT CODE HOLIDAYS 7:OOAM TO 5-30PM 8.-OOAM TO 5:OOPM NOT ALLOWED NOT ALLOWED 6:00AM TO 7:00PM 8:OOAM TO 5:OOPM NOT ALLOWED NOT ALLOWED VIOLATION OF THE ABOVE WORK HOURS IS A CITABLE OFFENSE UNDER PALM DESERT MUNICIPAL CODE SECTION 9.24.070. A. APPROVED TEMPORARY SANITARY FACILITIES (I.E. CHEMICAL TOILETS SHALL BE ON THE CONSTRUCTION SITE PRIOR TO REQUEST FOR FIRST INSPECTION). (HEALTH AND SAFETY CODE, SECTION 5416) B. CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS. (ORDINANCE NO. 262 PALM DESERT MUNICIPAL CODE) zl I C. STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT OF WHICH THE PERMIT IS ISSUED. QI I ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR THIS PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS ON FILE WITH THIS OFFICE. THE PUBLIC RIGHT-OF-WAY SHALL BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES. (PALM DESERT MUNICIPAL CODE, CHAPTER 8.02) D. SITE WALLS, RETAINING WALL, TRASH ENCLOSURES, POWER POLES, T SITE LIGHTING TEMPORARY O CARTPOR S S EMERGENCY GENERATORS, GREASE INTERCEPTORS AND SPRAY BOOTHS REQUIRE SEPARATE SUBMITTALS, APPROVALS AND PERMITS. E. GENERAL CONTRACTOR AND/OR OWNER BUILDERS SHALL SUBMIT A COMPLETED SUB -CONTRACTOR'S LIST TO THE BUILDING & SAFETY DEPARTMENT PRIOR TO REQUESTING A FINAL INSPECTION PER PALM DESERT ORDINANCE NO. 60. ABSOLUTELY NO SUB -CONTRACTOR'S LISTS WILL BE ACCEPTED UNLESS ALL REQUIRED INFORMATION IS PROVIDED ON THE APPROPRIATE FORM. NEW ADMINISTRATION BUILDING FOR: 73515 PALM GREENS PARKWAY PALM DESERT, CA. 92260 APPLICABLE CODES APPLICABLE CODES: (AS OF JANUARY 1, 2017) CALIFORNIA CODE OF REGULATIONS (C.C.R.) GOVERNING THIS PROJECT: 2016 CALIFORNIA BUILDING CODE, (base on the 2015 IBC) PART 2 2016 CALIFORNIA ELECTRICAL CODE, PART 3 2016 CALIFORNIA MECHANICAL CODE, PART 4 2016 CALIFORNIA PLUMBING CODE, PART 5 2016 CALIFORNIA ENERGY CODE, PART 6 2016 CALIFORNIA FIRE CODE, PART 9 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE, PART 11 2016 CALIFORNIA REFERENCED STANDARDS CODE, PART 12 PARTIAL, LIST OF APPLICABLE STANDARDS NFPA 17 DRY CHEMICAL EXTINGUISHING SYSTEMS 2017 EDITION NFPA 72 NATIONAL FIRE ALARM CODE 2019 EDITION (CALIFORNIA AMENDED) NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEM 2018 EDITION PARTIAL, LIST OF FEDERAL CODES AND STANDARDS AMERICANS WITH DISABILITIES ACT (ADA), TITLE II ALL CONSTRUCTION SHALL COMPLY WITH THE 2016 CALIFORNIA BUILDING CODE, WHICH IS BASED ON THE 2015 INTERNATIONAL BUILDING CODE (IBC). ALSO 2016 CALIFORNIA PLUMBING, MECHANICAL, ELECTRICAL, FIRE CODE, ENERGY CODE AND ALL OTHER LOCAL CODES AND ORDINANCES SHALL COMPLY. THE CITY BUILDING INSPECTOR HAS THE AUTHORITY TO REQUEST FULLY REVISED PLAN SHEETS WITH ALL FIELD CHANGES CLOUDED W/ DELTAS TO BE SUBMITTED FOR CITY PLAN REVIEW WHEN HE/SHE DETERMINES THE NUMBER OF FILED REVISIONS WARRANT SUCH A REQUEST. BUILDING ADDRESS TO COMPLY WITH ORDINANCE 1265. LOCATION AND HEIGHT TO BE APPROVED BY PALM DESERT BUILDING OFFICIAL. DEFERRED APPROVALS • TRUSSES • FIRE SPRINKLERS • FIRE ALARM THE BUILDING IS TO BE EQUIPPED WITH A NFPA 13 FIRE SPRINKLER SYSTEM AND FIRE ALARM SYSTEM. CONTRACTOR TO PROVIDE FIRE SPRINKLER AND FIRE ALARM PLANS INDICATING ALL FIRE SPRINKLERS /ALARMS. CONTRACTOR TO SUBMIT THREE (3) COPIES OF FIRE ALARM AND FIRE SPRINKLERS PLANS TO FIRE DEPARTMENT. SUBMIT SEPARATE PLANS AND FEES DIRECTLY TO THE FIRE DEPARTMENT FOR ANY MODIFICATION/ADDITION OF FIRE SPRINKLERS AND/OR FIRE ALARM SYSTEM. THE PLANS SHALL BE APPROVED BY THE ARCHITECT OF RECORD PRIOR TO SUBMITTING FOR APPROVAL TO THE RIVERSIDE COUNTY FIRE DEPARTMENT. RIVERSIDE COUNTY FIRE DEPARTMENT 73510 FRED WARING DRIVE PALM DESERT, CA, 93535 (760) 346-1870 -DEFERRED SUBMITTALS SHALL BE REVIEWED BY ARCHITECT OR ENGINEER OF RECORD PRIOR TO SUBMITTAL TO THE BUILDING OFFICIAL. OWNER PROJECT DATA BUILDING SCOPE APN MECHANICAL ELECTRICAL CONSTRUCTION FIRE NO. BUILDINGBUILDING HEIGHT AREA/ OCCUPANT OF W/ORK RYAN GALAZ, PE LEED AP MEP ENERGY SOLUTIONS, INC. 73-750 COUNTRY CLUB DRIVE OCCUPANCY TYPE SPRINKLERS STORIES (FT.) T.I. (SQ. FT.) LOAD NEW DANA POINT, CA 92692 INDIO, CA. 92260 LA QUINTA, CALIFORNIA, 92248 LA QUINTA, CALIFORNIA, 92248 LA QUINTA, CALIFORNIA, 92248 TEL: 760.346.8005 TEL: 760.779.1937 EXT. 21 FAX: 760.779.8744 TEL: 949.470.2323 TEL: 760.275.0553 ADMINIS-IRATION 620-170-006 TEL: 442.282.1109 B V -B YES 1 17'-0" 4,823 SQ. FT. 38 BUILDING CONTACT: REUBEN WALTERSE-MAIL: CONTACT: CRAIG R. ANDERSON CONTACT: LLOYD W. WATSON CONTACT: RYAN GALAZ CONTACT: RYAN GALAZ CONTACT: RYAN GALAZ E-MAIL: BREYNOLDS@PDGCC.COM REUBEN@PEARSON-ARCHITECTS.COM E-MAIL: INFORMATION@ANDSE.COM LEGAL DESCRIPTION EMAIL: RGALAZ@MEPESG.COM 620-170-006 EMAIL: RGALAZ@MEPESG.COM RECORDERS MAP BOOK #: 67 J 13-37 RECORDED BOOK / PAGE: 620 / 8-16 SUBDIVISION NAME: - A3.0 REFLECTED CEILING PLAN LOT/PARCEL: TT A3.1 REFLECTED CEILING DETAILS BLOCK: - a TRACT NUMBER: 4182 A4.0 ROOF PLAN [[[�� PROJECT SUM MARY CONSTRUCTION OF A NEW 4,823 SQ.FT. ADMINISTRATION OFFICE BUILDING AS FOLLOWS: A. CONSTRUCTION OF NEW OFFICE BUILDING; METAL STUDS EXTERIOR WALL FRAMING AND METAL STUDS INTERIOR WALLS. B. NEW HVAC SYSTEM A7.0 BUILDING SECTIONS C. NEW ELECTRICAL POWER & DISTRIBUTION D. NEW PLUMBING E-5.1 ELECTRICAL SPECIFICATIONS E. NEW SITE WORK: VEHICLE & GOLF CART PARKING UTILITIES WATER ......... ......................................... COACHELLA VALLEY WATER DISTRICT .............................................. ......... (760) 3918-2651 SEV\VER...................................................COACHELLA VALLEY WATER DISTRICT ....................... ................................. (760) 39'8-2651 GAS ........ .......... ............................................ -SOUTHERN CALIFORNIA GAS ............................................................ (800) 427-2200 ELECTRIC ......................................................SOUTHERN CALIFORNIA EDISON............................................................. (760) 482-9600 TELEPHONE..........................................................FRONTIER COMMUNICATION ......................................................................... (877) 775-6373 LE ......... CAB T.V................. WARNER /SPECTRUM ........................................... ............................. 888 8912-2253 .................................TIME A TRASH.......................... ...................................................... BURRTEC....... ........................ ................ ....... ............................ ...(760) 3410-2113 USA..................................................................UNDERGROUND SERVICE ALERT ................................................................ (800) 22.7-2600 2 OF 2 ONSITE PRIVATE WATER AND SEWER PLAN AND NOTES DigSafely UTILITIES NOTE DIG ALERT VERIFY CONNECTION POINTS FOR POWER TELEPHONE AND CATV SYSTEMS PRIOR TO P-0.3 PLUMBING SITE PLAN P-1.0 PLUMBING WASTE AND VENT FLOOR PLAN DIAL TOLL FREE CONSTRUCTION APPROXIMATE ONLY LOCATIONS INDICATED FOR TRANSFORMER LOCATIONS, STRUCTURAL 811 ETC. COMPLY WITH ALL UTILITY COMPANY REQUIREMENTS. PROVIDE ALL RELATED CONDUITS, \ PULL BOXES AND RISERS. CONTRACTOR SHALL VERIFY ACTUAL DEPTH AND LOCATION OF ALL SHEETI AT LEAST TWO EXISTING UTILITIES PRIOR TO CONSTRUCTION. CALL UNDERGROUND SERVICE ALERT (TOLL S-1 FOUNDATION PLAN DAYS BEFORE YOU DIG FREE 800-227-2600) PRIOR TO TRENCHING, GRADING, EXCAVATING, DRILLING, PIPE PUSHING, P-3.1 PLUMBING SYSTEM RISER DIAGRAMS PLANTING TREES, DIGGING FENCE POST HOLES ETC. THEY WILL SUPPLY INFORMATION OR UNDERGROUND SERVICE CALIFORNIA ALERT OF SOUTHERN LOCATE AND MARK ANY UNDERGROUND FACILITIES. APPLICABLE CODES APPLICABLE CODES: (AS OF JANUARY 1, 2017) CALIFORNIA CODE OF REGULATIONS (C.C.R.) GOVERNING THIS PROJECT: 2016 CALIFORNIA BUILDING CODE, (base on the 2015 IBC) PART 2 2016 CALIFORNIA ELECTRICAL CODE, PART 3 2016 CALIFORNIA MECHANICAL CODE, PART 4 2016 CALIFORNIA PLUMBING CODE, PART 5 2016 CALIFORNIA ENERGY CODE, PART 6 2016 CALIFORNIA FIRE CODE, PART 9 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE, PART 11 2016 CALIFORNIA REFERENCED STANDARDS CODE, PART 12 PARTIAL, LIST OF APPLICABLE STANDARDS NFPA 17 DRY CHEMICAL EXTINGUISHING SYSTEMS 2017 EDITION NFPA 72 NATIONAL FIRE ALARM CODE 2019 EDITION (CALIFORNIA AMENDED) NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEM 2018 EDITION PARTIAL, LIST OF FEDERAL CODES AND STANDARDS AMERICANS WITH DISABILITIES ACT (ADA), TITLE II ALL CONSTRUCTION SHALL COMPLY WITH THE 2016 CALIFORNIA BUILDING CODE, WHICH IS BASED ON THE 2015 INTERNATIONAL BUILDING CODE (IBC). ALSO 2016 CALIFORNIA PLUMBING, MECHANICAL, ELECTRICAL, FIRE CODE, ENERGY CODE AND ALL OTHER LOCAL CODES AND ORDINANCES SHALL COMPLY. THE CITY BUILDING INSPECTOR HAS THE AUTHORITY TO REQUEST FULLY REVISED PLAN SHEETS WITH ALL FIELD CHANGES CLOUDED W/ DELTAS TO BE SUBMITTED FOR CITY PLAN REVIEW WHEN HE/SHE DETERMINES THE NUMBER OF FILED REVISIONS WARRANT SUCH A REQUEST. BUILDING ADDRESS TO COMPLY WITH ORDINANCE 1265. LOCATION AND HEIGHT TO BE APPROVED BY PALM DESERT BUILDING OFFICIAL. DEFERRED APPROVALS • TRUSSES • FIRE SPRINKLERS • FIRE ALARM THE BUILDING IS TO BE EQUIPPED WITH A NFPA 13 FIRE SPRINKLER SYSTEM AND FIRE ALARM SYSTEM. CONTRACTOR TO PROVIDE FIRE SPRINKLER AND FIRE ALARM PLANS INDICATING ALL FIRE SPRINKLERS /ALARMS. CONTRACTOR TO SUBMIT THREE (3) COPIES OF FIRE ALARM AND FIRE SPRINKLERS PLANS TO FIRE DEPARTMENT. SUBMIT SEPARATE PLANS AND FEES DIRECTLY TO THE FIRE DEPARTMENT FOR ANY MODIFICATION/ADDITION OF FIRE SPRINKLERS AND/OR FIRE ALARM SYSTEM. THE PLANS SHALL BE APPROVED BY THE ARCHITECT OF RECORD PRIOR TO SUBMITTING FOR APPROVAL TO THE RIVERSIDE COUNTY FIRE DEPARTMENT. RIVERSIDE COUNTY FIRE DEPARTMENT 73510 FRED WARING DRIVE PALM DESERT, CA, 93535 (760) 346-1870 -DEFERRED SUBMITTALS SHALL BE REVIEWED BY ARCHITECT OR ENGINEER OF RECORD PRIOR TO SUBMITTAL TO THE BUILDING OFFICIAL. OWNER ARCHITECT STRUCTURAL CIVIL MECHANICAL ELECTRICAL PLUMBING PALM DESERT GREENS PEARSON ARCHITECTS, INC. ANDERSON STRUCTURAL ENGINEERING WATSON ENGINEERING RYAN GALAZ, PE LEED AP MEP ENERGY SOLUTIONS, INC. RYAN GALAZ, PE LEED AP MEP ENERGY SOLUTIONS, INC. RYAN GALAZ, PE LEED AP MEP ENERGY SOLUTIONS, INC. 73-750 COUNTRY CLUB DRIVE 74-260 HWY 111, SUITE 8 PALM DESERT, CA 92260 24-632 SAN JUAN AVENUE. #240 50-200 MONROE STREET P.O. BOX 6390, P.O. BOX 6390, P.O. BOX 6390, PALM DESERT, CA 92260 M-2.1 MECHANICAL FLOOR PLAN DANA POINT, CA 92692 INDIO, CA. 92260 LA QUINTA, CALIFORNIA, 92248 LA QUINTA, CALIFORNIA, 92248 LA QUINTA, CALIFORNIA, 92248 TEL: 760.346.8005 TEL: 760.779.1937 EXT. 21 FAX: 760.779.8744 TEL: 949.470.2323 TEL: 760.275.0553 TEL: 442.282.1109 TEL: 442.282.1109 TEL: 442.282.1109 FAX: 760.568.4965 M-5.1 MECHANICAL TITLE 24 FAX: 949.470,2324 CELL: CELL: 714.975.3501 CELL: 714.975.3501 CELL: 714.975.3501 CONTACT: ROBERTA L. REYNOLDS CONTACT: REUBEN WALTERSE-MAIL: CONTACT: CRAIG R. ANDERSON CONTACT: LLOYD W. WATSON CONTACT: RYAN GALAZ CONTACT: RYAN GALAZ CONTACT: RYAN GALAZ E-MAIL: BREYNOLDS@PDGCC.COM REUBEN@PEARSON-ARCHITECTS.COM E-MAIL: INFORMATION@ANDSE.COM ATSON@LWENG.COM EMAIL: LVVWW EMAIL: RGALAZ@MEPESG.COM EMAIL: RGALAZ@MEPESG.COM EMAIL: RGALAZ@MEPESG.COM SHEET INDEX ARCHITECTURAL MECHANICAL SHEETI SHEET DESCRIPTION SHEET SHEET DESCRIPTION T1.0 TITLE/COVER SHEET, VICINITY MAP, M-0.1 LEGEND, GENERAL NOTES AND + SHEET INDEX ABBREVIATIONS A0.01 ABBREVIATIONS, GRAPHIC STANDARDS M-0.2 MECHANICAL SCHEDULES + GENERAL NOTES + ACCESSIBILITY A0.02 ACCESSIBILITY DETAILS M-0.3 MECHANICAL DETAILS M-0.4 MECHANICAL DETAILS A0.03 SPECIFICATIONS M-2.1 MECHANICAL FLOOR PLAN A0.04 SPECIFICATIONS d' A0.05 SPECIFICATIONS M-2.2 MECHANICAL FLOOR PIPING PLAN A0.06 CALIF. GREEN BUILDING STANDARDS CODE M-3.1 MECHANICAL ROOF PLAN A0.07 CALIF. GREEN BUILDING STANDARDS CODE M-4.1 MECHANICAL SPECIFICATIONS A0.08 CALIF. GREEN BUILDING STANDARDS CODE M-4..2 z MECHANICAL SPECIFICATIONS A0.09 GEOTECHNICAL REPORT M-5.1 MECHANICAL TITLE 24 A0.10 GEOTECHNICAL REPORT M-5.2 MECHANICAL TITLE 24 A0.11 EXITING PLAN h ELECTRICAL A1.0 OVERALL SITE PLAN D1.0 DEMO SITE PLAN SHEETI SHEET DESCRIPTION O A1.1 ENLARGED SITE PLAN U A1.2 SITE DETAILS E-0.1 LEGEND, GENERAL NOTES AND N m ABBREVIATIONS A2.0 FLOOR PLAN A2.1 FINISH FLOOR PLAN E-0.2 DETAILS & SCHEDULES � w E-0.3 LIGHTING CONTROL DETAILS A3.0 REFLECTED CEILING PLAN Q z A3.1 REFLECTED CEILING DETAILS E-2.1 ELECTRICAL LIGHTING PLAN a E-3.1 ELECTRICAL POWER PLAN A4.0 ROOF PLAN [[[�� LLI E-3.2 ELECTRICAL MECHANICAL PLAN A6.0 EXTERIOR ELEVATIONS E-4.1 SINGLE LINE DIAGRAM A7.0 BUILDING SECTIONS E-4.2 PANEL SCHEDULES E-5.1 ELECTRICAL SPECIFICATIONS WINDOW A8.0 DOOR IN W HED DETAILS O SCHEDULE U E-6.1 TITLE 24 CALCULATIONS A9.0 ARCHITECTURAL DETAILS U A9.1 ARCHITECTURAL DETAILS Ir CIVIL (FOR REFERENCE ONLY) SHEETI SHEET DESCRIPTION PLUMBING Cj REED p T 1 OF 2 PRECISE GRADING PLAN y SHEETI SHEET DESCRIPTION 2 OF 2 PRECISE GRADING PLAN P-0.1 PLUMBING LEGEND, SCHEDULES, DETAILS 1 OF 2 ONSITE PRIVATE WATER AND SEWER PLAN 2 OF 2 ONSITE PRIVATE WATER AND SEWER PLAN AND NOTES Z P-0.2 PLUMBING DETAILS P-0.3 PLUMBING SITE PLAN P-1.0 PLUMBING WASTE AND VENT FLOOR PLAN W Lu STRUCTURAL U) E-- P-2.1 PLUMBING HOT AND COLD WATER FLOOR PLAN P-2.3 PLUMBING ROOF PLAN SHEETI SHEET DESCRIPTION S-1 FOUNDATION PLAN S-2 ROOF FRAMING PLAN P-3.1 PLUMBING SYSTEM RISER DIAGRAMS SD -1 GENERAL NOTES P-4.1 PLUMBING SPECIFICATIONS SD -2 STRUCTURAL DETAILS af SD -3 STRUCTURAL DETAILS �, W F fi SD -4 STRUCTURAL DETAILS SD -5 STRUCTURAL DETAILS U _jo NO. REVISIONS DATE LI � z w � O w U r CL d' N uai W a w� o x w Oz w o w~ z 0~ x W z z O o 0 z a 0 O a o a Z y N F E- Z 11111 M � Z U) h W r Q `) VJ� r O LLI ~ U W W ! F- N m W k Z � (D U � w C) z z w Q z < Q a [[[�� LLI W � W = x U Ir N Q r ARCh'i Cj REED p T N y NO.`C 11782 Q REN- 12.31.19 X W Z C W Q W Lu U) E-- Z Q H VV Z Q O W Q O z �1�_ C) af z U O z g, �, W F fi F_ �w U _jo z a� o a a Q ..n W z Plot Date: 11/14/19 Scale: AS NOTED Drawn: GUSRAYA Job: Sheet: T1.0 BUILDING DEPARTMENT SUBMITTAL SET - 11/14/19 - ---- - - - -- _ - - NO. REVISIONS DATE wQ z o C)w Q O z,0 :3 O 4~ z 7 w w Y O U Ld w0 w a w z x w z w w } z (n = O w z W r- x 4 O w 4 Z F z H W �- x x z z 0 Oz w Q~ w 0 p'w w ¢ K W z w a v 4'2 4 C� O x w = }O ttn F a = a � H U a " Z C — W o J 0 w U � W W Ov w Z_ < C, U Ld W _W z z Q z Q J W Q a 4t ' w W D W U N Z Q J W /- `I— U) v / J J Q tY W 0 O } L Q z Yo J Q N m C/) U z \ W F_ Q U) \\ U) 3 Q Z 7Lo ::":. x a- i� a r Q L? M W z Plot Date: 11/14/19 Scale: AS NOTED Drawn: GUSRAYA Job: Sheet: A1.0 BUILDING DEPARTMENT SUBMITTAL SET - 11/14/19 d I 3'-0" m 26'-0" 23'-0" 22'-0" 16'-0" A A -A6.0 -A7.0 - 7'-10Y2" 26'-0" 23'-0" a GENERAL NOTES 1. VERIFY ALL DIMENSIONS AND CONDITIONS ON THE SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING ANY WORK. 2. COORDINATE DETAILS AND DIMENSIONS WITH RELATED REQUIREMENTS ON ALL DRAWINGS. 3. THE GENERAL CONTRACTOR SHALL PERFORM SITE INSPECTIONS TO VERIFY EXACT EXISTING CONDITIONS. 4. DIMENSIONS ARE FROM CENTER OF STUD TO CENTER OF STUD UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY ALL DIMENSIONS WITH PRIOR TO START OF CONSTRUCTION. 5. FOR ALL FLOOR, CEILING, AND WALL FINISHES, REFER TO FINISH SCHEDULE ON SHEET A2.2. WALL LEGEND A EXTERIOR WALL: 2X6 STUDS AT 16" O.C. WITH R-21 BATTS INSULATION WITH 5/8" GYP. BOARD ON INSIDE AND 7/8" EXTERIOR CEMENT PLASTER SYSTEM. SEE i, J STRUCTURAL DRAWINGS FOR LOCATION OF PLYWOOD B INTERIOR WALL: 2X6 STUDS AT 16" O.C. WITH FULL THICK SONO-BATTS INSULATION AND WITH 5/8" TYPE "X" GYP. BOARD ON BOTH SIDES. OINTERIOR PLUMBING WALL: 2X6 STUDS AT 16" O.C. WITH QUIET -BATT INSULATION AND WITH 5/8" W.R. GYP. BOARD ON INTERIOR _ SIDE OF RESTROOM AND 5/8" TYPE'X' GYP. BOARD ON OPPOSITE SIDE OF x N') WALL. 5/8" W.R. GYP. BOARD ON BOTH �- SIDES WHERE BATHROOM WALLS MEET EACH OTHER. OD EXTERIOR WALL:; -"Y-- 2X6 STUDS AT 16" O.C. WITH R-21 BATTS INSULATION WITH 7/8" EXTERIOR CEMENT PLASTER SYSTEM. _ CONSTRUCTION KEY NOTES 1 FIRE EXTINGUISHER - REFER TO DETAIL - 3 & 4/A9.0. TRAVEL DISTANCE FOR FIRE EXTINGUISHER TO BE LESS THAN 75 FEET IN ANY DIRECTION. ElFLOORING - REFER TO ROOM FINISH SCHEDULE ON SHEET A2.2 aCOUNTER @ 34" - REFER TO DTL. 17/A9.0: PROVIDE BLOCKING AS NEEDED PER OWNER REQUIREMENTS F41 COUNTER @ 42" - REFER TO DTL. 17/A9.0 : PROVIDE BLOCKING AS NEEDED PER OWNER REQUIREMENTS MOP SINK W/ MOP RACK REFER TO SHT. A2.3 FOR SPECIFICATIONS 6] LADDER TO ROOF ACCESS -REFER TO DETAILS 5 & 13 /A9.1. '7 WATER HEATER - REFER TO PLUMBING DRAWINGS FOR SPECIFICATIONS F8] ELECTRICAL SWITCHGEAR - REFER TO ELECTRICAL DRAWINGS 1-91 FLOORING TRANSITION - SEE SHT. A2.2 FINISH FLOOR PLAN 11-01, FIRE RISER 11 ADA ACCESSIBLE DRINKING FOUNTAIN- REFER TO DETAIL 11 ON SHEET A0.02 F FOR ADA REQUIREMENTS. [12]NOT USED F13 +42" BOLLARD - REFER TO DETAIL 18/A9.0. [14]18" DEEP STORAGE SHELVES F151 TIME CLOCK- O.F.C.I. BUILDING DEPARTMENT SUBMITTAL SET - 11/14/19 +17'-0" T.O.PARAPET oL +16'-6" +10'-6" +10'-0.. .r. +7'-6" +O,-0" F. F. +17'-0-0" ,$-T.O.PARAPET — d� +16'-6" 0. P. + 10'-6" +101-011 +7._6.. +01-01, F. F. + F. F. QIOL +17'-0" W T.O.PARAPET Ll h +16'-6" O +10'-6" +10'-0" +7'-6" SCALE: 1/4" = 1'-0" NORTH ELEVATION SCALE- 1/4" = 1'-0" EAST ELEVATION SCALE: 1/4" = 1'-0" � IN N 0 OIL +0'-0" /f _ F.F. X 1 7 8 1 4 1 4 6 8 1 4 6 7 1 4 8 SOUTH ELEVATION z SCALE: 1/4" = 1'-0" w LL CONSTRUCTION KEYNOTES METAL STUD WALL W/ 7/8" EXTERIOR PLASTER SYSTEM OVER 1 - REFER TO WALL SCHEDULE ON SHT. A2.0 F2] 12" TALL ADDRESS NUMBERING F3] DOOR - REFER TO DOOR + WINDOW SCHEDULE SHT. A8.0 WINDOW AND/OR STOREFRONT WINDOW 4 - REFER TO DOOR + WINDOW SCHEDULE SHT. A8.0 5 SIDELITE - REFER TO DOOR + WINDOW SCHEDULE SHT. A8.0 6 DECORATIVE STEEL BEAM -REFER TO STRUCTURAL DRAWINGS CONCRETE SLAB AND / OR FOOTING - REFER TO STRUCTURAL DRAWINGS 81 8 PLASTER CONTROL_ JOINT, TYPICAL - REFER TO DETAIL 19/A9.0 WALL MOUNTED EXTERIOR LIGHTING FIXTURES 9 S - REFER TO ELECTRICAL DRAWINGS FOR TYPE NO. OL +17'-0" DATE T.O.PARAPET OL + 16'-6" +11'-0" — w U) T. 0. P. ` +9'-6" — E m 0 0 N +7'-6" + F. F. QIOL +17'-0" W T.O.PARAPET Ll h +16'-6" O +10'-6" +10'-0" +7'-6" SCALE: 1/4" = 1'-0" NORTH ELEVATION SCALE- 1/4" = 1'-0" EAST ELEVATION SCALE: 1/4" = 1'-0" � IN N 0 OIL +0'-0" /f _ F.F. X 1 7 8 1 4 1 4 6 8 1 4 6 7 1 4 8 SOUTH ELEVATION z SCALE: 1/4" = 1'-0" w LL CONSTRUCTION KEYNOTES METAL STUD WALL W/ 7/8" EXTERIOR PLASTER SYSTEM OVER 1 - REFER TO WALL SCHEDULE ON SHT. A2.0 F2] 12" TALL ADDRESS NUMBERING F3] DOOR - REFER TO DOOR + WINDOW SCHEDULE SHT. A8.0 WINDOW AND/OR STOREFRONT WINDOW 4 - REFER TO DOOR + WINDOW SCHEDULE SHT. A8.0 5 SIDELITE - REFER TO DOOR + WINDOW SCHEDULE SHT. A8.0 6 DECORATIVE STEEL BEAM -REFER TO STRUCTURAL DRAWINGS CONCRETE SLAB AND / OR FOOTING - REFER TO STRUCTURAL DRAWINGS 81 8 PLASTER CONTROL_ JOINT, TYPICAL - REFER TO DETAIL 19/A9.0 WALL MOUNTED EXTERIOR LIGHTING FIXTURES 9 S - REFER TO ELECTRICAL DRAWINGS FOR TYPE NO. REVISIONS DATE D w w LL W uIZQ U a OZo01� U a K W} O l ¢' U FU - a> W U W 0 U u� w a w v= w z w z X U z a O x a o 6 O w a g w~ Z O~_ z w w z 0z w a 0 F (n ¢ ww z w z_ a rc a 0 O a Z x a } a _ = a U z 7 Z cn m — W �- O � U W Wcq N Z z C) (D U � w Q, z z W � z � Q Q w a 0 ► w W D ~ r C) U Q N Q r ARC 'yi \G� �eED p� v �p 0 (p O NO- C-11782 REN. 12.31.19 OF C AL\FO U) Z 0 Q W J W _0 W O v_ Q 0 ❑0, < N J � Q N �U O wz i- �, Q \ w <01� .\ ` (D (n �G ❑ F_ $ \ W a _z ` Lr) Q Q � co W Z Plot Date: 11/14/19 Scale: AS NOTED Drawn; GUSRAYA Job: Sheet: A6.0 BUILDING DEPARTMENT SUBMITTAL SET - 11/14/19 l