HomeMy WebLinkAboutARROYO VIEW 320-16-71615_PLANSF I
6i
Ill
KITCHEN 2 @ 16 X 16
1,11 REQ
51.70
CPM REQ
31.02
OUT SIDE LIVING 2 5 1
-6 13-2
KITCHEN
NCO C7
C1
> C',
i
3 10 -
4 I
g, -4 13-2 -
CCPV /C PIPING APPLICATION
PIPE MAX: HANGER
SIZES SPACING
1 77 6' 0 77
c
INSPECTOR
TEST
_ 1
I
I I
1 1
5-1 i------- -1
b I
� I I
1
1 1
I I I
15
I I
1 to
7 1
-DINING
1 - 5- °y~
7-10
5-1 0-6 4-9
I
1
I � 1
GREAT ROOMA I
i 1
---- --- - - -- - ----5-7 4-7 Q 7-0
160 SRC
=� L-1 �j
�II� ®Ir -
-II�. ■ --- I V
L J'id
AUTOMATIC FIRE SPRINKLER RISER
1" CPVC ELBOW--\
SECOND FLOOR
�O 0 6" ELEC BELL
WIRED BY OTHERS
RISER MANIFOLD W/:
(1) DRAIN AND TEST
(2) FLOW SWITCH
65 (3) PRESSURE GAUGE
70 (4) SIGNS ON BODY
to
(5) PRESSURE RELIEF VALVE
z WATER FLOW SWITCH
=-- -- --= o .�
WIRED BY OTHERS
III
1 _ _ I RUBBER FACED CHECK VALVE
L -_- flo - HALL O =HYDRAULIC NODE POINT 120 1n� \
5 7-9 5-0 0
�0 6-3 1 -8 11-4 �+ ,
---------
1" SYSTEM RISER ------------ a
- - - - -- 46
1 SEE RISER DETAIL FOR ¢ 13-0
HYDRAULIC NODE LOCATIONS QQ
� ELEV. ®BOR: 1'-0"
p 60 65 70 100 T N 3 CAR GARAGE
LU
----- M c
OUTDOOR LIVING( BAR o
HANGER F1 ri F1
1 1 1
-' ' -TX10 -8 11-4
T
1 I
TOLCO FIG. 28 HANGE.RNESTRAINT ,� _ _ _ M ELEVATION -2'-0"
NOT 1.0 SCALE
- - - - -°Q� 3-3 1 -' - RISER DETAIL nts
5-5
1-
_ - - - - - - i 1 ---_ 1 77
LAUNDRY The installation of fire sprinkler systems or
11 Off' '2 CARTmodifications to existing fire sprinkler
zn THREADING F 'IC � 2-o i ® O - \GARAGE systems shall comply with:
��� • NFPA 13D (2016 Edition)
=Date:
Fees Approved by: Vf
Residential Connection Charge Estimate
Information Supplied By Customer
CVWD System Data
July 15, 2016
Service Connection**
Max. Flow= 43 gprn
Max. Flow*= 43 9PM
Customer Name:
Inlet Pressure 1= 11.0.8 psi
Striker Construction
Outlet Pressure= 86.7 psi
Phone No.(
760) 365-8691
Parcel No.
Meter Size = 1 inch
-M-006
Service Size= 1 1/2 inch
Geo.
06-06-06-1
Address:m
** For Calculation Purposes- Service Connection Includes:
`
Service Connection Pipe=50', Meter Stop, McLec k ulve & Shut Off Valve
LID:
679974 Block No.
Lot No.
w� rCl S kUA-e �
Size of Lot:
32,234
sq. ft. Tract No. 25296-3
Type of Service:
LO
R-1: J Duplex:
El
Triplex:
El
Apts:
SWSC:
$'
9,628.14
Acres:
0.74
SWSC: $13,011.00 /acre
WSBFC:
$
ce)
SCC:
$
4,851.00
a,
Treatment:
$2,436/edu Collection: $2,415/edu
Meter-
$
-
Meter Size:
1
inch
Meter surcharge:
$
2,479.00;
Service Size:
11/2
inch
Service:
$
-
Meter & Service: $ 3,910.00
Backflow: $ -
Other: $ 600.00
Sewer Lateral: $
Total- 15 21,468.14
Technician: Ruben Montiel
Fees Approved by: Vf
I Date: e
Information Supplied By Customer
CVWD System Data
Domestic Water Demand*
Service Connection**
Max. Flow= 43 gprn
Max. Flow*= 43 9PM
Min. Pressure= 60 psi
Inlet Pressure 1= 11.0.8 psi
Fire Sprinkler Demand*
Outlet Pressure= 86.7 psi
Max. Flow= 43 gpm
Min. Pressure= 46 psi
Meter Size = 1 inch
System Type: ❑ B
Service Size= 1 1/2 inch
Multi Stand Alone
1 Prior to Pressure Regulating Valve
** For Calculation Purposes- Service Connection Includes:
* CVWD USES WORST CASE CONDITION
Service Connection Pipe=50', Meter Stop, McLec k ulve & Shut Off Valve
b Calculations: Rp Ff
f
64411-4 6 01
PZ= Res. # _ _ Res./Ht=-22l�
HGL= „1X Property Elev.= 7.7'9 ` E ,NIC C5619`
w� rCl S kUA-e �
Appoved by. Date:,
The meter sizing is for plan check purposes only. The ultimate responsibility resides with the Engineer -4f- Record for the project.
w
Z
W
Q
0
E—+
rn
�
CV
W
w
M
LO
�
�
o
w
4
ce)
CV
w
w
,—�
o
A
ce)
a
Z
a,
m
Q
F�
0 1
W �
o
j
jE
TbLCo NIG. 28 S I AND HALL
OFF" HANGER California Building Code (2016 Edition). o 0
co
® 30 HALL 32 �4� OPEN TO ABOVE - o00 M - • California Fire Code (20 16 Edition). INSTALLATION NEEDED OF A SEPARATE " DOMESTIC ONLY " VALVE TO
,� N 1 1 1 • California Residential Code (2016 Edition). ALLOW SERVICING OF THE DOMESTIC SYSTEM WITHOUT IMPAIRING THE FIRE SPRINKLER SYSTEM.
T. 15--0 15-0 6-9 �, 6-10 -_ _ ( 0
[� °° — - 1 -� - _ - •
PALM DESERT fare prevention NFPA 13D 2016 IS THE INSTALLATION STANDARD.
VEIN
- -
�4 ----
N OG 28 5 38 The Fire Prevention Bureau will require the following inspections THE SYSTEM CHECK VALVE ON THE RISER SHALL BE OF RUBBER -FACED CONSTRUCTION. m Uj Uj
A --- ----- - 1 — 1- A and tests as a minimum:'
0 O
- - - --
J J J
1 1 1 1 N 1 - 1 _ ALL RISER ASSEMBLIES SHALL BE ENCLOSED IN A WALL/BUILD UP WITH EASY ACCESS
a 7 0 15-8 � 4-11 s-9 2-a- 5-3 s 3-s - _7 • Overhead installation @ STREET PRESSURE
N 1 AND WITH AN APPROVED ACCESS DOOR, UNLESS OTHERWISE APPROVED BY THE FIRE DEPARTMENT. N �,
HALL 1 ,� - - - - • Final fire sprinkler.
-- ------ EST 2 \ • TO SCHEDULE INSPECTIONS, CALL THE FIRE 2016 IS THE CURRENTLY ADOPTED STANDARD.
SINGLE FASTENER PIPE CLAMP
1 EDROOM y 2016 CFC IS THE FIRE CODE. CLAMP TOLCO FLG. #22 OR EQ v.
' MASTER D M] a 2-8 _ 4- 5-6 _--___- J DEPT day before the inspection.
N WOOF STRUCTURE,
I1 26 6-1 AS OCCURS
MASTER BATH - --- HANGER APPLICATION
1 1 1 1 1-10 3-1 1 DETAIL DOUBLE FASTENER STRAP HANGER Sprinkler Spacing: _16 x �16 Feet o o
- - 9 SELF -THREADING HEX HEAD ® N19
� I
8-
i 9 12-6 5-11
_ -)ESCRIPTION: PIPE HANGER FOR DOUBLE FASTENER PIPE CLAMP SCREW AS FURNISHED BY 1
--jATTACHMENT OF CPVC TO TOP OF
® _ ti -- TOLCO FIG. #24 OR EQUIVALENT HANGER MANUFACTURER
WOOD sTRucTRUAL MEMBER NOTES FOR NFPA 13D SPRINKLER SYSTEMS W
DPa _ _ _ ONE & TWO FAMILY RESIDENTIAL FIRE SPRINKLER SYSTEMS
p O
PIPING FLOOR PLAN CPVC PIPING APPLICATION DWELLING.
CH 2=} a
SCALE 1/8 -=1' PIPE MAX HANGER J
Z —
0 DESIGN CRITERIA TE RETAINER APPLICATION HANGER APPLICATION Z a Z y
----- SIZES SPACING -----,--.- s� a 4/0 a' a W a W a 3 0
1) THIS SYSTEM IS A WET PIPE SYSTEM OF AUTOMATIC co F<RE S eFtis� SINGLEFASTENER _ � _ w 0 LL w w
1 6 O SPRINKLERS HYDRAULICALLY DESIGNED PER Q �`' ys� a, �I o
W � �� C-16307848 �� 0 r-
NFPA 13D WITH TWO HEADS FLOWING. i Exp 12-31-17 N -P STRAP !Z!�.LVGER
OR TRUSS CHORD, AS OCCURS r OD
2) ALL PIPING TO BE CPVC BLAZEMASTER NO SCALE
DOUBLE FASTENER STRAP WITH CPVC GLUED FITTINGS sTq� GNATV� \P 'C PIPING APPLICATION
3) ALL MATERIALS TO BE U.L. LISTED OF CA"'O, 6' 0° MAX HANGER
X15'-2"A.F.F. 16-2"A.F.F. 144"AFS CPVCPIPINGAPPLICATION 4) UNDERGROUND PIPE COVER MINIMUM OF 20 INCHES SPACING_�- PIPE MAX HANGER
SIZES SPACING A full port ball valve shall be installed at one - and two-family Dwelling units as a shut
domestic and fires sprinkler water supply. A shut -off valve shall be installed for the WELL water supply
Ppp Y
DOUBLE FASTENER PIPE CLAMP, after the fire sprinkler system take off is to be the off valve for both
TOLCO FIG //23 OP FOUIVALFNT
An inspector's test valve must be provided from a remote portion of the system. Orifice size
4 0 ® same as the smallest sprinkler in the system. This valve shall be a full port ball valve with signed access
panel and a stub outside the wall.
MASTER BEDROOM _ HER CLOSET GUEST 1 BEDROOM 0- GUEST/2 BATH GUEST 2 BATH GUEST 2 BEDROOM YOGA
x P Sprinkler head shall be installed in attic areas
Ii:W
over the Forced Air Unit .
DOUBLEFASTENER WOOD STRUCTURE,
SECTION As OCCURS Where solvent cement is used as the pipe and fittings bonding agent, sprinklers shall not
- A STRAPHANGER SELF -THREADING HEX HE AD
scuE ,�_
4)V-113RT--------------------------------__-_--___--_-_------- ___--_____ ____________ _____ ___ _________--_----------------------------------- No SCALE SCREW AS FURNISHED B" be installed in the fittings prior to the fittings being cemented in place. APPROVAL
1
18'-0" A.F.F. HANGER MANUFACTURER RISE COUNTY FIRE DE-PARTNIEe"IT
Pendent sprinklers no closer than three feet of the center of a ceiling fan. B -
S'a SINGLE FASTENER STRAPHANGER FIRE SPRINKLER DESIGN CRITERIAJarmas Aldrich
DAA l ` ! 7 cA� _ i
r�
SINGLE FASTENER PIPE CLAMP All valves shall have permanently affixed signs that designate their function,
THE FIRE DSI T.APP Ai PLAiN
b 4 UD FOR
CLAMP TOLCO FLG. #22 OR EQUIV. The water flow switch shall be connected to the service panel on an house circuit. c0.d. LI .VCE V I h I P ;e` 66 _ COOL3
zIr
ILL SELF -THREADING HEX
OOD STRUCTURE, SCREW AS FURNISHED Bells/alarms shall be sized and located to be clearly audible
- AS OCCURS HANGER MANUFACTUR
At least one bell/alarm shall be located near the address side or front side of the
10'-0" 0'-0"
structure and shall be listed for exterior use.
es" n
F ,` — - MECH 1_ DINING ENTRY BAR MASTER BATH (� `n
1�R4. OO a. inspection required at both rough and final prior to occupancy being granted. RECEIVED
—
— b. Systems shall be tested at a minimum of street pressure in accordance with NFPA 13D. MAY 16 2017
Sprinkler Spacing: _16 x _16 Feet` RIVERSIDE iCOLfJTYFIRE DEPT N
SECTION B RETAINER APPLICATION No SCALE �-� leso.��e ,�,�('I?%
COVE COMMUNITIES FIRE MARSHAL
E—+
�
(�
O
LO
Wrn
0
o
w
4
ce)
CV
P�1
U
ce)
a
w
z
W �
o
j
jE
TbLCo NIG. 28 S I AND HALL
OFF" HANGER California Building Code (2016 Edition). o 0
co
® 30 HALL 32 �4� OPEN TO ABOVE - o00 M - • California Fire Code (20 16 Edition). INSTALLATION NEEDED OF A SEPARATE " DOMESTIC ONLY " VALVE TO
,� N 1 1 1 • California Residential Code (2016 Edition). ALLOW SERVICING OF THE DOMESTIC SYSTEM WITHOUT IMPAIRING THE FIRE SPRINKLER SYSTEM.
T. 15--0 15-0 6-9 �, 6-10 -_ _ ( 0
[� °° — - 1 -� - _ - •
PALM DESERT fare prevention NFPA 13D 2016 IS THE INSTALLATION STANDARD.
VEIN
- -
�4 ----
N OG 28 5 38 The Fire Prevention Bureau will require the following inspections THE SYSTEM CHECK VALVE ON THE RISER SHALL BE OF RUBBER -FACED CONSTRUCTION. m Uj Uj
A --- ----- - 1 — 1- A and tests as a minimum:'
0 O
- - - --
J J J
1 1 1 1 N 1 - 1 _ ALL RISER ASSEMBLIES SHALL BE ENCLOSED IN A WALL/BUILD UP WITH EASY ACCESS
a 7 0 15-8 � 4-11 s-9 2-a- 5-3 s 3-s - _7 • Overhead installation @ STREET PRESSURE
N 1 AND WITH AN APPROVED ACCESS DOOR, UNLESS OTHERWISE APPROVED BY THE FIRE DEPARTMENT. N �,
HALL 1 ,� - - - - • Final fire sprinkler.
-- ------ EST 2 \ • TO SCHEDULE INSPECTIONS, CALL THE FIRE 2016 IS THE CURRENTLY ADOPTED STANDARD.
SINGLE FASTENER PIPE CLAMP
1 EDROOM y 2016 CFC IS THE FIRE CODE. CLAMP TOLCO FLG. #22 OR EQ v.
' MASTER D M] a 2-8 _ 4- 5-6 _--___- J DEPT day before the inspection.
N WOOF STRUCTURE,
I1 26 6-1 AS OCCURS
MASTER BATH - --- HANGER APPLICATION
1 1 1 1 1-10 3-1 1 DETAIL DOUBLE FASTENER STRAP HANGER Sprinkler Spacing: _16 x �16 Feet o o
- - 9 SELF -THREADING HEX HEAD ® N19
� I
8-
i 9 12-6 5-11
_ -)ESCRIPTION: PIPE HANGER FOR DOUBLE FASTENER PIPE CLAMP SCREW AS FURNISHED BY 1
--jATTACHMENT OF CPVC TO TOP OF
® _ ti -- TOLCO FIG. #24 OR EQUIVALENT HANGER MANUFACTURER
WOOD sTRucTRUAL MEMBER NOTES FOR NFPA 13D SPRINKLER SYSTEMS W
DPa _ _ _ ONE & TWO FAMILY RESIDENTIAL FIRE SPRINKLER SYSTEMS
p O
PIPING FLOOR PLAN CPVC PIPING APPLICATION DWELLING.
CH 2=} a
SCALE 1/8 -=1' PIPE MAX HANGER J
Z —
0 DESIGN CRITERIA TE RETAINER APPLICATION HANGER APPLICATION Z a Z y
----- SIZES SPACING -----,--.- s� a 4/0 a' a W a W a 3 0
1) THIS SYSTEM IS A WET PIPE SYSTEM OF AUTOMATIC co F<RE S eFtis� SINGLEFASTENER _ � _ w 0 LL w w
1 6 O SPRINKLERS HYDRAULICALLY DESIGNED PER Q �`' ys� a, �I o
W � �� C-16307848 �� 0 r-
NFPA 13D WITH TWO HEADS FLOWING. i Exp 12-31-17 N -P STRAP !Z!�.LVGER
OR TRUSS CHORD, AS OCCURS r OD
2) ALL PIPING TO BE CPVC BLAZEMASTER NO SCALE
DOUBLE FASTENER STRAP WITH CPVC GLUED FITTINGS sTq� GNATV� \P 'C PIPING APPLICATION
3) ALL MATERIALS TO BE U.L. LISTED OF CA"'O, 6' 0° MAX HANGER
X15'-2"A.F.F. 16-2"A.F.F. 144"AFS CPVCPIPINGAPPLICATION 4) UNDERGROUND PIPE COVER MINIMUM OF 20 INCHES SPACING_�- PIPE MAX HANGER
SIZES SPACING A full port ball valve shall be installed at one - and two-family Dwelling units as a shut
domestic and fires sprinkler water supply. A shut -off valve shall be installed for the WELL water supply
Ppp Y
DOUBLE FASTENER PIPE CLAMP, after the fire sprinkler system take off is to be the off valve for both
TOLCO FIG //23 OP FOUIVALFNT
An inspector's test valve must be provided from a remote portion of the system. Orifice size
4 0 ® same as the smallest sprinkler in the system. This valve shall be a full port ball valve with signed access
panel and a stub outside the wall.
MASTER BEDROOM _ HER CLOSET GUEST 1 BEDROOM 0- GUEST/2 BATH GUEST 2 BATH GUEST 2 BEDROOM YOGA
x P Sprinkler head shall be installed in attic areas
Ii:W
over the Forced Air Unit .
DOUBLEFASTENER WOOD STRUCTURE,
SECTION As OCCURS Where solvent cement is used as the pipe and fittings bonding agent, sprinklers shall not
- A STRAPHANGER SELF -THREADING HEX HE AD
scuE ,�_
4)V-113RT--------------------------------__-_--___--_-_------- ___--_____ ____________ _____ ___ _________--_----------------------------------- No SCALE SCREW AS FURNISHED B" be installed in the fittings prior to the fittings being cemented in place. APPROVAL
1
18'-0" A.F.F. HANGER MANUFACTURER RISE COUNTY FIRE DE-PARTNIEe"IT
Pendent sprinklers no closer than three feet of the center of a ceiling fan. B -
S'a SINGLE FASTENER STRAPHANGER FIRE SPRINKLER DESIGN CRITERIAJarmas Aldrich
DAA l ` ! 7 cA� _ i
r�
SINGLE FASTENER PIPE CLAMP All valves shall have permanently affixed signs that designate their function,
THE FIRE DSI T.APP Ai PLAiN
b 4 UD FOR
CLAMP TOLCO FLG. #22 OR EQUIV. The water flow switch shall be connected to the service panel on an house circuit. c0.d. LI .VCE V I h I P ;e` 66 _ COOL3
zIr
ILL SELF -THREADING HEX
OOD STRUCTURE, SCREW AS FURNISHED Bells/alarms shall be sized and located to be clearly audible
- AS OCCURS HANGER MANUFACTUR
At least one bell/alarm shall be located near the address side or front side of the
10'-0" 0'-0"
structure and shall be listed for exterior use.
es" n
F ,` — - MECH 1_ DINING ENTRY BAR MASTER BATH (� `n
1�R4. OO a. inspection required at both rough and final prior to occupancy being granted. RECEIVED
—
— b. Systems shall be tested at a minimum of street pressure in accordance with NFPA 13D. MAY 16 2017
Sprinkler Spacing: _16 x _16 Feet` RIVERSIDE iCOLfJTYFIRE DEPT N
SECTION B RETAINER APPLICATION No SCALE �-� leso.��e ,�,�('I?%
COVE COMMUNITIES FIRE MARSHAL