Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Pele Development_1
PH Lanbscape Designs LLC 37-879 Hollister Drive Palm Desert, California 92211 Office: (760) 574-7411 fax: (760) 779-0216 email: patric hlandscapedesian.com t May 02,2008 City of Palm Desert Public Works Dept. Attn: Diane Hollinger Palm Desert, CA 92260 Re: Pete Place NW comer of Portota Ave. & Frank Sinatra Dr. Dear Diane, As the landscape and irrigation are in the final stages of installation at Pete Place, the 110 volt power supply required for the irrigation controller was never installed. So with that,the irrigation controller as called out per plan will not work accordingly. Southern California Edison is asking for over$27,000 to install a drop line service from an existing power pole,which is a cost that the bank/builder is not willing to bear. We are proposing to substitute the 12 station irrigation controller as called out on the plan with an 'ALEX-Tronix' BCS-10 Lithium Ion battery powered irrigation controller.This is a 10 station controller to be used with 'ALEX-Tronix' BCS-SOL latching solenoid actuators attached to the existing irrigation valves and 14AWG min.size control valve wire. This combination, per ALEX-Tronix specifications will supply ample power to the control valves at a maximum distance of 5 miles using the specified 14 gague wire. Per the approved plans, the distance to the valves are as follows: 550 feet to the farthest valves on Portota Street and 290 feet to the farthest valves on Shepherd Lane. Please refer to the attached sheets for specifications of the above mentioned irrigation equipment. ---------- ____ Amended Landry pe Retro-Fit Plan Reviewed BY: Thank you for your consideration to this matter. Landscape Mgr. l da/ Date,/. �'�G1D t � // Regards, CITY of PALM DESERT PUBLIC WORKS DEPT. Patric Herring, ASLA CLIA Landscape Architect, CA # 5417 U ar :a n J � 1b 9TE OF ChL�FO� Page 1 of 1 (E)MASONRY WALLS (D P.O.C.-VER.EXACT LOC.IN FIELD 314"METER-vd T'R.F.DEVICE PER CM TRACT#33018 -PALM DESERT Shepard Ln. Sidewalk-Planting Pele Development Revisions-As sullt BCE:wA 04121i1'1:. -APPROVED - Landscaoe Re ro-Fit Plan Reviewed BY: Landscang Mcr.. Date CITY of PALM DESERT PUBLIC WORDS DEPT. r' hq://emaiisecureserver.net/download.php?rand=25801&folder=iNBOX&uid=178&parr... 2/21/2007 I Page i of 1 (E)MASONRY WALLS • a o + © •n o P.O.C.-VER.EXACT LOC.IN FIELD 3/4"METER-rv/T'R.F.DEVICE PER CVWD TRACT#33018 - PALM DESERT Sheperd Ln. Sidewalk-Planting Pele Development Revisions -As Built SCALE:WA -APPROVED - Landscape Retro-Fit Plan Reviewed BY: Landsca IM Date if CITY of PALM DESERT PUBLIC WORKS DEPT. Y` http://email.secureserver.neVdownload.php?rand=25801&folder—INBOX&uid=178&parr... 2/21/2007 PH Lanbscape Design, LLC 37-879 Hollister Drive Palm Desert, California 92211 Office: (760) 574-7411 fax: (760) 779-0216 email: patric(fthlandscapedesign.com May 02, 2008 City of Paliti Desert Public Works Dept. Attn: Diane Hollinger Palm Desert, CA 92260 Re:,Pele Place NW comer of Portola Ave. & Frank Sinatra Dr. Dear Diane, As the landscape and irrigation are in the final stages of installation'at Pele Place, the 110 volt,power supply required for the irrigation controller was never installed. So with 'that,-the^irrigation controller as called out per plan will not work accordingly. Souther California Edison is asking for over$27,000 to install a drop line`service from an existing power pole,Which is a cost that the bank/builder is not willing to tear. <; .-We are proposing to substitute the 12 station irrigation controller as called out,o,n the plan with an 'ALEX-Tronix' BCS-10 Lithium Ion battery powered irrigation controller.This is a 10 station-controller to be used with 'ALEX-Tronix' BCS-SOL latching solenoid actuators attached'to the existing irrigation valves and 14AWG min.size control valve wire. This combination, per ALDC-Tronix specifications will supply'ample power to the control valves at a maximum distance of 5 miles using the specified,l4 gague wire..Per the approved plans, the distance to the valves are as follows: 550-feet to the farthest valves on Portola Street and 290 feet to the farthest valves on Shepherd.Lone. Please refer to the attached sheets for specifications of the above mentioned irrigation equipment. [Date .APPROVED - ended Landst aoe Retro-Fit Plan Thank you for your consideration to this matter. ed BY: ape gr. l Regards, Ale — Regards, of PALM DESERT PUBLIC WORKS DEPT. Patric-Herring, ASLA CLIA Landscape Architect,CA # 5417 J a S� Z ap VV 9lF OF CAS\f� r Alex-Tronix BCS Page 1 of 3 BCS 5 10 Battery Control Systems) The Next eneration of Power See Our New Stainless Steel-Pedestal-Control Mount Alex-Tronix recommends using the BCS Sjwith the BCS Battery Y on i` ystems.For more information,click here. Owner's Manual Installation Instructions(pdo Quick Programming ' Downloadable Spec Files: Downloadable Specification File:(Word) BCS Field Installation:jpg or of BCS Wiring Diagram:jpg or of Pedestal Retrofit 001 initrol IBOC P-2b:ipg or of Pedestal Retrofit 001 New Installation:jpg or of Pedestal Retrofit dig altec:jpg or of . Pedestal Retrofit dig altec solatrol 4000:jpg or of Pedestal Retrofit dig alter solatrol 8000:jpg or.t'd BCS Specifications: Irrigation Controllei(Lithium battery-operated) The controller shall be a solid state irrigation controller powered,lithium batteries. The vandal and water resistant controller is enclosed in a powder- coated, commercial grade metal enclosure. A stainless steel enclosure or pedestal,is also available to house said controller. The panel has an easy tow read display rated for high temperatures up to 158 degrees Fahrenheit The.`"f controller shall operate in an outdoor setting(in extreme heat or cold)ands,!' power latching solenoid actuators. The BCS can operate valves up to five miles with 14 gauge irrigation wire. If the SSPED Stainless Steel Pedestal.is specified then the galvanized pipe is not applicable. BCS 5&SIFeatulres and Advantages: +:, 1. Five and ten station models.(plus pump or master valve). 2. Up to five year valve battery life(batteries in Uu. 3. Five mile valve operating distance with 14 gauge(1.6 mm)wire. http://www.atex-tronix.com/bcs.htm '�, l 5/2/2008 Alex-Tronix BCS �" "`� ^ `. '<.�ii"." "" . - Page 2 of 3 a 4. Functions and stations rotary switch programming. 5. Two valves per station operating capability. . 6. Self powered removable panel for programming at a convenient location. 7. Two independent programs, 4 starts per day per program. 8. Automatic, semi-automatic, and timed manual operation. 9. Water budget function in 10% increments from 10-200%. 10. Valve test function (invented by Alex-Tronix in 1977). it. Watering based on days of the week or interval of days. 12. .Rain delay function up to 99 days. 13, Watering up to 23 hours and 59 minutes in,one minute increments. 14. Adjustable delay between stations. 15. -Powder coated outdoor metal case with lock and hasp. Optional stainiess.steel case available. 16. Swing out front panel with quick connect output terminal for easy servicing with ample wiring space: 17. Easy to read high temperature liquid crystal display. 18. Battery operation and open output relay contacts virtually eliminate surge problems. 19. Power failure proof and electrically safe installation and troubleshooting. 20. Pulsed power eliminates bumed.out coils due to excessive voltage. 21. Optional solenoid module compatible with Rain Bird®or Hunter® latching solenoid. 22. CIT(Center for Irrigation Technology)tested for valve compatibility, distance, and battery life: - 23. Optional latching relay allows operation of lights, pumps, or other industrial controls. . 24. .Pulsed DC current eliminates capacitive coupling problems associated with AC powered systems and galvanic copper wire deterioration of steady DC operation. 25. Extremely low power allows use of small gauge multi-conductor cable. 26. Long distance operation allows use in place of AC power controllers. 27. Recognized and sponsored by the U.S. Department of Energy for energy efficiency. •28. Patented technology. 29. 100%burned in and functionally tested. 30. .Two year warranty. Electrical Specifications Electronics current in idle state: 30 microamps Electronics current while programming: 3 milliamps Valve current draw:40 milliamps per valve for 1-3 seconds, 2 valves maximum per station Electronics power.4400 milliamp-hours Valve power.four 9 volt lithium batteries in series, 1200 milliamp-hours Mechanical Specifications Standard and SSE Stainless Steel Enclosure size: 8.25x7.5x5.2in6hes, 21.0x1 i0x13.2cm. Weight 8.0 lb, 3.6 Kg SSPED Stainless Steel Pedestal Size: 35.5 x 7.5 x 5.25 inches, (91 x 19 x 13 cm). Weight 23 Ib,(10.5 Kg) http://www.alex-tronix.com/bcs.htm 5/2/2008 Alex-Tronix Latching Solenoid Information Page 1 of 1 t• Latching Solenoid Information BCS LATCHING'SOLENOIO(eCS SOC) 'LATCHING SOLENOID(Cs) For use vAth the BCS series only :For use with Me Smart-Alex. Enermn.and SS Serles Valve Compatability Chart SEE A TTAcA W 4,44OB r5 Alex-Tronix recommends using the model LS (Latching Solenoid)with all of its battery powered controllers. The LS is a 12 VDC two wire polarized latching solenoid. It requires a short DC pulse to turn it on, and a reverse polarity DC pulse to de-energize it. No energy is required to keep the valve open. The black lead is the common and the red lead is the positive. Caution:connecting the leads in reverse will cause valve to stay on when it is supposed to be off, and off when it's supposed to be on.Consult valve compatibility chart for adapting the LS to various valves. The LS can be operated directly by the Enercon and Smart-Alex series controllers. The BCS requires a module attached to the LS for proper operation. This combination for the BCS is the model BCS-SOL. The BCS is normally used for extremely long distances(over 2000 feet), or when more than one valve must be operated at a time per station. Consult factory before using any other latching solenoid with any of the Alex- . Tronix battery powered controllers. I Home I Turf d Le 5C.Po I Agrkueurel New Pmduas I Report erW inlmmatbn I T�SPPDmt I I oafs anual n an sla0a -utrudlons I DowMoea Spec Piles I Turf Price Ust I!a Prke_Etsl I 6bout Us I ContasLU$l htq)://www.alex-tronix.com/latchingsolenoidinfo.hi3n 5/2/2008 IRRIGATION VALVE COMPATIBILITY CHART As of 6-01-07 Use this chart to insure compatibility of the Alex-Tronix LS latching solenoid or BCS SOL to these valves when using the BCS, ENERCON, and SMART CLOCK battery powered controllers. Consult factory for valves not listed. Two"O" ring sizes are supplied,the thinner-015 and thicker-205 with each LS and BCS SOL. MANUFACTURER VALVE SERIES COMPATIBILITY Baccara G75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use solenoid as is Bermad 200. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use solenoid as is Buckner VB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015 "O"ring Dig PN10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use solenoid as is Griswold 2000(iron),DWS (brass) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015"O"ring Hit310 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . .Use extra-015 "0"ring Hunter's HBV(brass) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-0205 "O"ring Hunter@ ASV,HPV,ICV,PGV, SRV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See note below Irritrol®/Hardie 100,205TF,2711APR, 2713APR . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015 "O"ring Initrole 700. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015 "O"ring and do not remove override adapter. Irritrol®/Richdel 311A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015 "O"ring Irritrol®/Richdel 300 valve adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015 "O"ring Irritrole 2500TF,2623DPR,2400T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use solenoid as is Lawn Genie L7010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015 "O"ring LR Nelson 7900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use solenoid as is Olson AGV-100 PRO 8111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015 "O"ring Olson AGV-100UTL8121F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use solenoid as is Orbit®WaterMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use solenoid as is R-MR& :.. . . . . . . . . . . . . . .Use adapter AT-RB PEB, PESB, PGA or TBd Tm LS Superior450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . se solenoid as is Superior 950(brass). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-0205 "O"ring Toro'EZ Flo,EZ-Flo Plus,EZF,P220,220. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Use extra-015"O"ring WeathermatiO 11000CR, 12000CR,N-100SF, 21000CR, 8200CR . . . . . . . . . . . . .Use adapter AT-WMA NOTE: Hunter' valves ASV, HPV, ICV, PGV, SRV using the Hunter' latching solenoid are recommended for use with the Alex-Tronix Enercon, Smart Clock and BCS series controllers. The BCS uses the BCS RB to operate the Hunter latching solenoid, while the Enercon and Smart Clock can operate the Hunter latching solenoid directly. Alex-Tronix is not responsible for incompatibility due to valve manufacturer design changes,defects or other unforeseen problems.ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALEX-TRONIX A DIVISION OF GNA INDUSTRIES, INC. 4761 West Jacquelyn Avenue • Fresno, California 93722 Telephone (559) 276-2888 • FAX (559) 276-2890 • Toll Free (888) 224-7630 E-Mail: controlsCalex-tronix.com 9 http//www.alex-tronix.com ENERCON and BCS QUICK PROGRANMMG INSTRUCTIONS 1. Read Owners Manual including cautions before operating controller. This is only a quick reference. 2. Push any button for one second to activate display. Display goes off one minute after the last time any button is pushed or a switch rotated. Controller operates normally whether display is on or off 3. AUTOMATIC: Rotate FUNCTION SELECTOR to STATION ASSIGNMENTS and press SELECT. Now SELECT again to pick program A or B. Rotate STATION switch to station to be assigned and press ENTER. Pressing ENTER again will eliminate that station from the program. Continue assigning stations until both programs are completed. Rotate to WATERING DAYS and program in the same way as station assignments. Days of the week or intervals of days may be programmed on either or both programs. The day you program is the first day of the interval of days. Now rotate to WATERING DURATION and press SELECT. Rotate to the station desired and adjust the watering time for each station. Press ENTER after each station.To program starting times, go to START TIMES A or B. Press SELECT and four sets of starting times are displayed for each program. Select and adjust each starting time. Use the+adjust to set AM or PM. -:-- on the display indicates no starting time is programmed. When all starting times are set, ENTER. 4. SEMI-AUTOMATIC: Rotate to SEMI-AUTO and SELECT to enable function. SELECT again to choose A or B and ENTER. Each station assigned to the selected program will come on in sequence if it has watering time.After one cycle,program shuts off. Each program can be started independently. Semi-automatic operation will terminate the automatic program in progress. 5. MANUAL: Go to MANUAL STATION and turn STATION rotary switch to station desired. SELECT and adjust time to hours and minutes of watering,then ENTER. To stop manual operation, ENTER again. Manual operation disables the valves of automatic program in progress. Program resumes at the end of manual operation where it would have been had it not been interrupted. 6. BUDGET/DELAY Press SELECT to choose budget or delay and press ENTER. SELECT and adjust cho- sen function,then press ENTER. In budget, every station watering time in automatic and semi-automatic will be changed to the selected percentage ftom 10-200%. Once budgeted, no station time can be changed unless budut is returned to 100%. A % symbol on the screen means that other than 100% has been selected DELAY is time delay between stations in seconds. 7. TEST: To see if assigned valves are operating properly, go to the TEST function and SELECT. Program test time from 1 to 99 minutes and ENTER. Every station assigned to A or B programs will come on in sequence for one cycle. Testing interrupts any automatic program in progress.Automatic program resumes after testing is completed. 8. RAIN DELAY: To stop irrigating for one day or more, rotate FUNCTION SELECTOR to RAIN DELAY. Press SELECT and program the number of days you do not want watering.After the rain delay has elapsed, the normal irrigation program will resume automatically. 9. In CONTROLLER OFF, SELECTING and ENTERING ends irrigation cycle. CONTROLLER OFF means that no automatic or semi-automatic cycles are possible,which can only be started after con- troller is turned back on. Manual and test cycles are possible in the OFF condition, and the OFF state is displayed in the RUN and CONTROLLER OFF function positions. 10. Program may be reviewed at any time without affecting operation. 11. Station watering times may be changed at any time prior to that station being activated, except that they may not be adjusted unless budget is set to 100%. Alex-Tronix Controls, A DIVISION OF GNA INDUSTRIES,WC. 4761 West Jacquelyn Avenue • Fresno, California 93722 U.S.A. Telephone(559) 276-2888 • FAX (559) 276-2890 •Toll Free (888) 224-7630 E-Mail: controls@alex-tronix.com • http//www.alex-tronix.com 1 L O � 41 a d O +� v w H cd Q) Y d O y +' L U fVd w Us a '� - a L N C N U ° V V d = A d u C C CC C- 0. 7 E .- c ; C cd u by a N V 0 -O L 7 tv N d) V t' d) -O t C N OL d C C V �' N O N = HNO = � •� Vca 3 cd > 41 a • N IA cL > ,a > d N ° a cC . tLcd C i NO a+ d G bQ V Cd C j> -0 xV C OO L cad U w > s o _a U N N ° 7 In .'C--'-+ > O N > N O Y -° b U cd °- 'O cn N 09 ;� d L sa " b c am box4- ° ct 0 0 d N_ O IN O d y N L ci 0 0 -° O �j;j IA (mod d -0 E Y d L d Y C y o N 3 p L c`d (A E cn •� O V - 3 c ° EO — L ((A 3 "O N C 40 V) � 7 m N d) N U -0 C CO Lb0 V N C O E C •n _° ° C 00 U tNd N _ - L s W N d C cd d 3 0 O. s O E O U CO a 'E 3 0 0 a +' Y O C L N > 3 O L U V ° y a aO+ > L L 4' N 'L C a� .c d0 3 bbo � c � i, 7 � OL 7 O u H � d � " > O Y � � � N � C7 `= ° � ocna° Y ° � 0 � � 3 rd o ° o ri M ui %D r� co 0% C) c X 0) O -0 O } Iq c o O O O ap Q � Na } A)� ' E 7 O x 0 C N O - cn N CN O N a > _ � n N N C c � a > U a N O 3 QL N Q z �j N w — O O w C Q O U Q U Z O v I l PLANT LEGEND (00 _ TREES �I WATER PLANT i II ! I $ 5YM. NAME 51ZE GOMMENT5 QTY. QTY. QTY. QTY. U5AGE FACTOR 51n le Trunk O O L 0.2 Acacia smallll 24 box g I o f I eM eM Sweet Acacia to L I v � 1 I I acla encore 24" box Single Trunk p I I O L 0.2 o 0 n v 2 D I ❑ I O -- - - 2 Gercidlum f. 'Desert Museum' 24" box 5ingle Trunk O 1 0 O L 0.2 v I ( I I -0Palo Verde o s �- _ ( - + I Oleo Europeo '5wan Hill' 24" box Multi-Trunk I 0 I I M 0.5 .4 > C 5 \ a Fruitless 011ve � N a 0 5chlnu5 Molle, 24" box 5ingle Trunk 0 0 0 1 M 0.5 Pepper Tree p c� m K� a a a a a 12 (+ + ctx�' �� ❑ + I • I PALMS �`� �� ev�� Q,,�J +12 I / ' 5YM. NAME SIZE COMMENTS QTY. QTY. QTY• QN, ��� PLANT \ � FACTOR • _ \ - / \ O \ + O� + - _ E.�. Ghomaerops humps 24" box Multi-trunk 1 1 2 1 M 0.5 II - BM BM r \ _ - I � +�� O / / e \ \ 1� --'-' Mediterranean Fan Palm / - �} + \ / / I \ ' eM - +1 2 " \ ° ® wa5hln tonla hybrid see plan 5kinned 2 2 2 2 H 0.8 -�-� \ I \ BMA _ - _ Hybrldan Palm (� N - , \ _ / v N BM _ _ ��� ��/1 /h �� �J Q 6300 9O �. _ _ _ _ - - - �.C.- - SHRUBS ems ` " � WATER PLANT O O O 5YM. NAME 51ZE COMMENTS QTY. QTY. QTY. QTY. U5A&E FACTOR t/'1 o 8 ci N-a eM BAileya multiradiato 1 gal 3 4 5 3 L 0.2 'O _ Desert Marigold A j ' •1- Bougainvillea rosenka 5901 Low Growing 3 2 1 2 M 0.5 ( I ® Bougainvillea Rosenka Doe Do .. ; N •= OX Galllandro colifornica 5 gal. 1 2 3 3 L 0.2 O) o E Bala Fairy Duster �) :c � Gaesalpinea pulcherrima 5901. 0 1 O 1 M 0.5 :o _ 0 Red Bird of Paradise U � s �- co CL PLANTNrFE �� 2 NORTH t T� 3 I 1• NOi�TH Cassia nemo hila L 0.2 p 5 gal I 2 � � M 3 Green Ga5slo I OLantana montev(densts 'Purple' 1901 Purple 1 1 4 1 M 0.5 Purple Trailing Lantana 1 I i Lantana monteviden5(s 'New ��old' 19a1 Gotd 5 6 4 4 M 0.5 New 6oid Trolling Lantana 1 I D + � Leucophyllum frutescen5 'Green Cloud' S gal 5 3 3 5 L 0.2 'E Green Cloud Texas Ranger )J� I I Mulenbergta rigens 5 gal. 4 3 3 0 M 0.5 12 I I Deer Grass Ruellio penlnsularis 5 gal. 3 I 3 I L 0.2 Ell - / O Desert Ruellia C),G; D ��� I / i x I / _ \ w� I � DESERT ACCENTS Q,y�� Q,��� Q,,��� Q���>x + + _-_ I \0 - 5YM. NAME 51ZE GOMMENT5 QTY. GTY. QTY. QTY. U5 6E FACTS i- e U I 12 Agave vlimorinlana 36" � NO Scars I I 2 I L 0.2 I Octopu5 Agave A 1 X./ I 8M y Y II- O I � � D Desert o5poone I art 5 GAL. I I 1 1 L 02 F--i I � I 2 L 0.2 X �z II I i Hesperoloe parviflora 5 6AL. 2 3 +12 s O li eM - I O Red Yucca a 6M +Cp + ,a1 I i ry tx 1� ' I i VINES \ ❑ + sM \ a PLANT p I O II / WATER FACTOR j \ \ O - - - I �� M �'1 ( 5YM. NAME 517E GOMMENT5 QTY. an. an. QTY. U5AGE ❑ \ ; _ i Bougainvillea 'Barbara Karst' 15 6AL. WIRE TO WALL 1 0 Boy ainvllleaO 1 M 0.5 9 15 GAL. North WIRE To HALL 5 A �J i I X / I �I . Galitandra inae ullatera south, East 8 O I Pink Powder Puff I O M 0.5 West facing Walls ❑ � I I GROUNDCOVER 0 �` \ 5YM. NAME 51ZE GOMMENT5 !i NORTH _ I D.G. Decom osed Granite 3/8" minus Stab(lized, 2" layer after 'Brimstone' compaction _ 42. Avdll ® 5•W. Boulder�\��� NORTH � Landscape Boulders s heduleder Avail ® S.W. BoulderPLAN E ;31r PLA ���!/! Gresto Lr/ o $bo°Q Rubble Rock (P Avail ® 5.W. Boulder ~ I � City of Palm Desert City of Palm Desert City of Palm Desert pp p Water cafculaCronChart � ����I"� TO SHEET �I -2 �Ofi�r i=Lr41�� �E��f 1-5 and S�'�Cf�iC�4�"iONS Water Calculation Chart _ /'` A�1DEfR ,'') PLAN 2 TYPICAL FRONT YARD LANDSCAPE Water Calculation Chart fRE t-- ��' ILf=-L t' {-+e� I I V O T 0 �- C +-•' t PLAN 4 TYPICAL FRONT YARD FANDSCAPE Maximum Water Allowance PLAN 3 TYPICAL FRONT YARD LANDSCAPE ' City ofl�almDesert 'Maximum Water Allowance fREFER TO 5� 4EET L�-2 FOfR LAND6C,4f=E L1r_;;�TfNG LEGEND ' Maximum Water Allowance a m ne (4: �-fit thawz0oa Water Calculation Chart Square Footage Calculations PLAN t TYPICAL FROM YARD LANDSCAPE Square Footage Calculations Tree 8 Shrub Square foot 14?9 Square Footage Cateulatfon5 Turf Square foot 0 Tree&Shrub Square toot ,9a6 Tree6ShrubSquarefact ,2,6 GERALD FORD DRIV Maximum Water Allowance Tort Square foot a Tabl Squae footGobbte!(ioWder 0 Total WaterteaMe Square foata9e -tr Tud Squaretogt 0 Total Square foot CobDlelBoulder 0 •t!"1 Input Zone Total Landscape Square foot 1429 1 Total Total WateSquarfeaMe Square footage 0 TotalLaaerta e S Square footage 0 Total Landscape Square foot 1216 ' Zone No. Eto Water Ad' Total Conversion Factors Trial Total Larrdseape Square foot 7806 Square Footage Calculations Factor .ft. 0.82 748 MINA Zone No. Eto Water, Total Conyers 1 Factors TOW 1 57.01 0.5 0 O.Bo 748 ° 2orre No. Eta Water Total Conversion FaaWrs Total I Factor R 0.62 748 MWA f Tree&.Shrub Square foot i455 0 68.82 0.5 0 0.62 748 0 Factor iL 0:82 748 MWA 1 M8 0.5 0' 0.62 748 O Tre&Shrub Square 0 3a 75 0.5 0 0.62 746 0 , 57.0, 0.5 0 O.B2 T46 0 2 86,82 0.5 D O.t12 748 0 - APPROVED - W. •`• Total Square foot CODble/BOWder 0 2 8 0.5 0 0.82 748 0 38 75 0.5 0 0.82 748 0 Total WatMatwe Square footage 0- 3b 88 OS 0 0:82 748 0 3a 75 0.5 0 0.82 748 0 3b 88 Ob 0 0.82 T48 0 Total Landscape Square foot t455 4. 93.9 0.5 1429 0.62 748 55.61064 3b Sa 0.5 ° 0.62 748 0 4 93.9 0.5 1216 0.82 748.47.32156 FINAL LANDSCAPE PACKAGE 4 Ma 0.5 ISM 0.62 T40-74.17347 t Zone No. Etc Water Ad! Total Conversion Factors Total # rr��ll Facooe S R 0.62 748 MWA I Total f4tattber of pbr4s 36 � 777 Total M;mbw of pbr� 3t f1�L�+1 t 57.01 0.5 0 0.62 748 0 tNnttber of b water use %ot Total LandscaM Square Footage Total Number of Plants 1. ..J M1Nrrraber of loots water use %otTa0.648 cace Square Footage -"' • •� 2 56.82 0.5 0 0.62 748 0 1 Low 17 OAT2 674.806 Number or arll6 water use %of Taw larM6cace Square Footage a. 0.000 0.000 �1 Low 17 0.548 666.839 3a 75 0.5 0 0.62 748 0 2 Lowltbod $55.7? 1 Law 21-': 0.625 t000:650 2 Lord 0 0-000 53.00 tt�Alt1'nnS�r������a 36 88 0.5 0 0.82 748 0 - 3 Mod t4 0.389 2 LowfAlod .0 0.000 mow 1 3 Mod 9 0.290 353.032 LIUriJa7LtfirG IYIIi1Yf1 4 93.9 0.6 1450 0.62 748-56.82245 4 Mod f M 0 0.000 0-� 3 Mod 18 0.325 619.450 1 4 Mod!Hi 0 0.000 0.000 ^ 5 Mod 0. 0.000 0.000 ! 4 Mod/Hi 0'. 0,000 0.000 15 High 0 0.000 0.000 t Z F60 0.D56 79.389 5 High D 0.ON 0.000 6 Low Trees 0 0.000 0.000 I I .677 6 Low Trees -' 0,000 Total Number of plants ® 7 Low9dod Trees 0. 0.000 6 LavTrees 1 0.025 47.650 7 LovdAiodTrees _ 0 0.00a 0.000 Numtier of gams water use %of Total Landscace Square Footage 8 Mod Trees 1 0.0?8 39.694 7 LowlMod Trees 0 - tr.000 0.000 ;8 Mod Trees -3 0.097 1t 000 1 Low t7 0.472 687.083 9/dodati Tree 0 0,000 OADO 8 Mad Trees 3-': O.WS 142.950 I9 MoNHi Tree D 0.065 0.000 2 Lo�AAad 0 0.000 87. 10 M d Trees > 0.056 79.389 'i 9 ModlHi Tree 0-: O.Ow 0.000 ;YO Tota Trews 2 0.065 78.452 I 10 High Trees 0.050 95.300 Total 31 (AyLU 3 Mod 14 0.389 S65.833 Total 38 as- 4 Ned 10 0 0.000 0000 i Total 40 5 High 0 0.000 0.000 6 Low Trees 1. 0.026 40.417 .. .... _ - -... . - - .... . _. ..... ... _ ...._ .. p. Piata1br19Mlon system TYDe: Zone k[.Efl. Area Seasonal PIeM Factor `: _ O 1 7 Lowfhiod Trees 4 0.000 000 ._. ... _ _ hr. Elf. Area Seasonal Plant Faeror: sgayl&1�pFh, 4 0.75 o.oao 9 MotlRNgh Tree Marrefrrigafion n Tvae: lane Irc.Efl. Area Sasaw Plata Factor: T Zone irt.CM. Amer Saasaal Plats Factor. - 80.833 Plara✓NN1Ngott System Type, Zorw -.. 0.056 : ......__. _.._. __ ._... T... ._._. - SoravlerrblOriP 4 `09: 667 1 Low Shnrb-.._ �4 0.T5' ycmrs 9 8 Mod Trees 2 .. _.. -i 9 ModMi Tree 0 0.000 0.000 S raYBubIDrID 4 0.9 s75 1 Low Shrub . - seem Zaalfde Ptert Nat Gonwrsien Fawrs E>tlrY4 2 0.056 80.833 season Zonal Eta .P+aiv wee CgmeaptFarAvs Esanrf4 Piattflmgadon SrstemTVOe' Zotte ter.EfF... Ares _.Sasoretl PbiR Feretor. P{arNlttioadon SyiMn Type: Zane M.Eff. Area 9aaaW Pbnt FaMOr. Sason Zonal C'to aav 10 High Trees sexion zany Em Pleat Plea eraersgn Facmrs Esemare4 SP*aNaublDdp 4 OA not 1 L,Ow Shrub { R74 6a08 8 Ttoe To1a1 36 Vyue Facts s.R. 0.a2 ]e0 p,Efl. WamrUse Valor Fagg .ft. 0.62 lea ini.ER. WamrUse _ Verb Fadr sq.R 0.@ id6" y4:dl. War Use Nb Fade ¢ 0@ 746 ME¢ Waw W+ O V r (� 20.68 0.65. 0 062 T46 0.75 ^ 7arvlEb PYrt area CaawaimFaosa Erbabd Semen Zonal EOo ant an. Farris E>tarrW 20.68 0.2 866:8367 0.@ 746 0.9 2.54 20.69 0.65 0 0.@ Ter 0.75 R 0s2 74a MF¢. Wew tra Verb faor R da2 7 - M sP:,a 20.69 02 674.8058 0.62 ]ere 0.9 2.57 wow Famr 46 �. Warr W. /t ':stymie 5729 0.85 D 08z lee 0.75 � y„L"_' V surana 57.29 0.2. 674.8056 oat Toe 0.9 7_i2 �Fa-Vranr 95,97 D.B6 0. a62 Toe OJ5 - 20.W 0.2 t000.85 oat � 746 0.9 3.81 _.._ 20.09 ..0.85. 0.. oat ....746... U. I FM� x� 0.2 666.9387 a@ 746 °.9 7.04 �� 5L29 0.65 0 Om 74a 0.75 0.� Fat-wets 15.97 0.2 -374:8056 a@ lee 0.9 1.99 D.00 Saaerp 5T.29 0.2 1000.85 Osx 74s 0:9 10.56 2 666.8387- osz 746 Q9 1.96 4iNar 15.97 Ob5 0 0@ 746 Q76. TOTAL. 11.68 TOTAL 4Mar 15.97 0.2 1000.65 OAZ TO 0.9 2.94 5720 0.85 0 O@ TN 0.75 OTAL ,1.54 ' "' t %} '^ ' +�a M Planutmeaboar Sytert Type: Zace Irc.Hf. Area seasonal PbM Factor. pyt8r•-r^afWn Syatem Type' Zone Irc.EtL Area _ Seas Ptah Fatten TOTAL 1T.32 F.WMr ,5.97 tr.� a om 746 D75 f t !x FRf�tNK 51N�TRA DRIVE 4 0.75 poop 9 Moan hTree Zone Irt.d1 Area __seasonal Plats Factor. PIaaR[rigatiort 8vstamTYpe: Zone k[.di. Area seasanalPlaetfacto[: ' AL OAO PlanUirigatiat System Type: Zone Irc.Efl. Area 8asorw Plot factor: pgmdrrnadoo SYatem Type- Zone frr.Eff. Area 8asead Pb*Factor r�:o.a � -�� 1 SOraWauWDnp 4 0.9 66T t Low Shrub 5pnYBoNONP PIaMPofigaHat System Twe. SPraYIBtdNOflP 4 0.T5 19.389 10 hTree PlaotAnidalbrtSMem7yoe: Zeme ter.@fl. Area Seasorttl PWaFaetor: 4 0:9 oA00 2 LowlMeld Shrub SprayAYhlOnp �"a g' 4 0.75. 7<A$Z 10 Twe y R S{"'mg �tLr E a S"•�`' Smson Zaalf Prot Na CanrsbnFaGors FSsanrmr4 Swsn ZOrw Etc Pit Ara °arrerrion Fates EadeaW Sp�yl6�,�p 4 0.9 0.000 -2 LovpMotl Shrub _ O rat Far R 0.@ lea ail.CiF. woes Vso hen Conversion Facmrs Esrwrae Season ZOrrel Ft. Plait Mee CdwaiodFamn C-stvrwk4 Sperry f7p 4 49:: 0a00 2 LatMMod Shrub PlarMrcfaalbw Sfat4trt Zone In. Ar4a Ba4gW Plan Facto: Sesser. Zonel@o art Nee Cmvwslm Favhs fakwed aecae ZarValca Ola2 Camrdon FacersM� k Jt T,l 7%sp.T. I Vasa Fatmr era¢ a@ 74B a4.Ea. W Us4 Vab Season Zonal EtO Plan Vawe Facer .R. 016Z Toe ari.ER Wear Use Tom• 4 '..0:75'. 9RdW 10 H TrM Verb Fria R OR ]46 Mf3 Walelke S•+"�., t .� e„ ..,•5 p " "9' 20.69 02 687.0833 aez 7a9 0.9 262 stag 20.69 0.85 O a@ 746 0.75 vawe Fats• s.a. 082 Tae mi.Ert. wwruse Sara Zonal Eto era Arco Caraym Papa [-rintatd �n Zorral Eto Par nna can rsinfars Esamra spire 67-29 0.36 0 om 746 °.9 sat le 2D.68 OB 78.45181 0.@ 746 0.75 7.44 h NII 'SAE L0 if tub as"`1 SITE O �i So" 20.69 0.35 0 6sz Tab 0.9 sp.eo 20.68 0.8 79.38888 osz 7aa 0.75 1.45 vw. Fabr .R n@ 746 m.ER WMrtJ� sua,aa - 57.29 0.2 687.0833 osz 746 0.9 7.25 Sure.+w 57.29 0.65 0 a@ 746 0.75 spas Vaw faces R a@ 741 MFT. Wrrus• sums 5728 0.35 0 a@ T49 0,9 Bawer 57.29 0.8 78.46181 os2 7M 0.75 3.97 Fat-awes 1597 0.2 BS7.0833 os2 T46 0.9 2.02 FM,Wae,r 15-97 0.65 0 osz l4e 0.75 sunny 5729 0.35 0 0.67 lea 0.9 sar.Mr 57?e 0.8 79.388s9 0.62 Tae 0.75 d.02 yr„a 20.gg 0.35 0 psi TM 08 TOTAL ,1.89 TOTAL Fy1.Werr f5.97 0:36 0 oat Ma 0.8 15.97 0.8 79.38889 0.ez Tae 0.75 1.12 Srarvlr 57.29 0:35 0 0.@ 746 a.9 20. 0.8 953 0.@ 746 0.75' t.74 Fag-latter Y5.97 0.35 0 Osz We 0.9 6.52 Foe Wirmr Ftl-Wear 75.97 0.8 T8.45161 Ost 74e 0.75 1.71 ir•r"r•1'f'l Oil t'3 0.00 i TOTAL 6:59 Fal firer 15.97 U.35 O Oat 746 0.8 5729 0.8 95.3 092 7M 0.75 4.83 TOTAL 0.00 TOTAL Piartllrtigat(on System Twe: Zara irt.C•ff. Area Souorw PWaFactor. pbMBaipatlar SytarrTyce: Zone Irr.Efl. Area Se_w_nM Plant Factor: TOTAL P6-wart 15.97 °.S 95.3 09x 7a 0.75 1.35 RR PP�a t-LETTER R1 60d3S 90 Tree Total Tree And Shrub 46.02 TOTAL 0.00 _ TOTAL 7.92 • �,f•�'d' V $.'i5' &. 6Tw.w'f Spsy/euW I 4 OA. 6a00 2 LotYIMPd Shrub Sprayl9ubNdP 4 'Q75 TOW Toll And Shrub 39.44 "-" 6 A+ Jp� �t°1T,B .y.�3 Sawn Zonal.Eto era Nat CatwyaFraas C-sfiwlod 5avan 2orel Eto age era gonwrsba Ferias Famwe¢4 sonr PUM Foetor: awnal Ptah Factor: Total Tree AM Shrub 60.44 Piaotarti0adon System Typo: Zone hr.Efl. Area Seasonal PlaRFactor: r is PL iJe97 'r.J' Frpr .R o.@ 746 era.dr wyerUa• yaw• Fsw ¢ 0.@ 74a ME6. wag use PYanUNril3agon system Type: Zotte br.E/L Area Sea PlrmWrfo" syst-Type' Zone br.ER Area s Spray/BublDfiP 4 OA SStai2 3 ��-Twe: Zone Or.EN. Area SaasotW PhMFactor. ^ E Verb Spr lBtBHOrip 1 9.9 555.722 3 Mod SDroW9rdNONP 4 ex 0 ,1 Turf ; Ptuarm igaOottSYstemType' Zone ire Efl Area eeaserWPbntFartor: - $ .• • ®• rt T Value 0:35 0 M 746 0.9 20.89 0.8 80.83333 0.@ 7M 0.75 1-48 4 AA H9A60 3 Mod WanMrnOatlon System Type: Zone Irt.Eli Area 8-onal Plani Factor. S-art Zonal EW Pro era f:alwyatFadors F a„aat 4 am 0 71 Turt +# a- .� /j) 1 V 4.09 Seasdt Zonal ElO Plant Area Conxrswn Fa:m(s EsemrW Season ZOrrd Et. Gant Mee rslar Ferias Esmmtetl Swm ZMal E00 PM Nag CarterrrrRaara EttataY! �✓ I . Surreear 57.29 0.35 a 0.@ 746 0:9 57.29 0.8 80.63333 a@ 749 0.75 SPraWaubtOdp 4 ,:,:off'. 0 11 tort I vow Fades sat¢ os2 Toe ari:aF. wow Use ,5.97 0.35 tr ab2 Te8 0:9 y.aW err 15.97 0.6 60.83333 a61 T46 a.75 ,.14 Yyw Fxmr s.R. 0.62 ]4a M.E6. Y'Hler Use Valr factor s.R 092 Toe 4ri.En. WaRr Use Saaorr r!Oltal EtO Ftnt Nat CragltkrtFatiors Esawla0 Yea+• Farce a4R O.R 74a MER WMw Vs• Faa4Y.r 20.69 0.5 555.7222 osz iae 0.9 5.?9 20.68 0.76 0 os2 Tae 0.8 j van. fear era¢ o.@ 7e8 MEY. wow Ube seen Zonal Be err. Na caaasrlrFadae [-wamaas 20.69 0.5 353.0323 asz 746 0.9 3.38 �/ Straw Sglaw 20.69 0.76 O a@ T48 0.84 t I� TOTAL J00 TOTAL 8.71 �✓tsieD 20.Be 0.5 618.45 ob2 Td6 0.9 5.80 salwrr 5729 0.5 555.7222 0.@ 7a5 O.S 14.66 f s,anmr 20.69 0.6 0 pet Tae Q.8 Ysb Fade 0, os2 746 MFar. WawtW 5729 0.5 353.0323 a@ 74e 0.9. 9.31 Surer 67.29 D.8 0 Ps2 746 0.8 "'' ?4 o�I Total Tree And Shrub 48.12 Fall.ytrarr 15.97 0.5 655.7?22- os2 Toe 0.9 4.09 jFar•yr- 15.97 0.76 0 O.s2 74a 0.8 Suauer 6729 0.5 61ff45 osz 746 0.9 1" Mae 0.76 0 0.@ To e8 Poa4Alnrr 15.97 0.5 353.0323 bs2 74s 0.9 2.BO Fa-yelorr 15.97 0.78 0 0.@ 7m o.6 TOTAL 24•� !TOTAL 0.00 Fag-eKtr 15.97 0.5 619.45 0.@ T46 0.9 4-56 5729 0.8 0 0.@ 746 0-8 TOTAL 1537 TOT/IL. 0.00 t2ute NO /�� L Plantllrrfaatbrr Svsfem Twee. Zoce In.Efl. Area 8asaw(MmtFacror. fgamArttpatiog System Type' Zone Irt.Eff. Area _ Saasaui Plats Factor: TOTAL 26.80 •yWrr 15.97 0.78 0 oe1 74a 09 '.• `•.�/1 SpraYleublOnP 4 Oa 665.433 3 Mod S 4 0,8 0 t1 Turd Total tort 0.00 TOTAL 0.00 Piatrghriaraws System TYPt: Zeta Irc.Efl. Area eeasgrw Pbodmig: Total Turf 0.00 �r.a.� a ICI.t�T_i ,l-("`.S°."fi 1:11(,•, ytdiTr(�{� PraR Nat canadateacrrs Esaara Cneuaraian Fades Taynram4 PlarNtrrmaeort System Tyoe: Zone Irr.Efl, Area Seasonal pnM Factor: aant/brMatfon SMem Two: Zone Irt.Efl. Area 8atarW Plata Facer: S agSublDdp 4 : 8.8. 0.000 4 h f {7 s.wre Zonal Eta s.ra Zonal!!to era Am Vrw Facbr w.R a@ 7w Mm. Walerllaa SptaVlatdlOrkt 4 0.9 O.oOo 4 MoN h PfanArtiaa6onSVstem'type: Zone hr.Eri. Area SeasonalPbnrFxtor: Tact Tor/ 0.00 PWr6lrHaalonSwlanTioe: Zara IMP. Area 84asolWPfaatFactor: F: u•TYv `'+.t'\rNz. VC+:• Faga R 0.@ 746 M.ER WamUse $playl&Ib/UdP 49A. Os60 4 Saar Zonal Eta oat Nat CarnerimFadrs Esellvbd w1 spiv 20.89 0.5 585.8333 o.6z 74a 0.9 5.39 20.. 0.76 ° oat 746 0.8 season ZonalEro art Mee conw,aln Facmn Esamaea Wffierteature 4 1 0 12 MovM Sonar W Pit Nw t CarraraienraAws 12 Moving Fyarra ` A 57.29 0.5 565.8333 osz T4a 0.8 14.93 vawe Factor .R 0.sz Tae p.E1F. wauruse I seam ZonA. Pin Nag °aaairrFarrs Es6+uba piaNlnlabdareaturo YPc Zone ter,Efl. Area eeaoawPbmovinor: Veb Facer sae OAZpsi 7de RR.Fd. wawua. om 1 �.a•� Srrmr 57.Z9 0.6 0 Am 748 D.6 season Zonal Qo Pun Ara CornersianFaces Estmsm4 Vab Few R 0.62 746 ad.ER wowtae 20.89 0.85 0 am 74B 0.8 N�(,,�, 748 0.9 4.16 0.8 20.68 0.85 0 os2 Tae 0.9bf1/teallNe < 1 d 12 abN 57.28 .2 ¢0 psi 74e r.�1 BASF- I N�OI I/ DTI ON fa dwter 1597 0.5 5658333 get Fag me, 15.97 0.76 0 o.@ 74B vane Faces .rt. o@ iae m;.err. W.W.wyeruse 1D.88 0.65 0 oat 748 0.9 20,89 t2 0 0sz 746 1 24.48 0.00 5729 0.66 D 0.s2 Tae 0.9 5•a,a Zeal Eta Pit Ina CaraairrFacrs Eearrlar4 Sooner 57.29 0.85 0 a@ 746 0.9c3.P j Fag-Wier 15.97 0.65 0 0.@ 746 0.8 �rer� ♦ .�.. TOTAL TOTAL Soma ;swig 20.69 12 0 082 toe- 4 Suvw 5729 0.85 0 a@ 746 OA Vab Fates t Ob2 746 Mrde. W4ertW j 8r-err }r� r}� x 1\� Fa:-Vamr 15.97 °.66 0. an Tae 09 512a 12 0 0.62 ]ere 1 Fat4rlawr 16.97 0.85 C asi 746 0.9 20.69 1.2 0 0.@ TI6 t TOTS °'00 Fri firer 75.97 1.2 tr ofii 746 1 7�"1�• � . ��I.Nir.r l `�i ti�/ I��/, Plantlbrlortlon System TYP. Ze" Irc CM Area a M"_PfaM Facer. Toot Turf 0.tb TOTAL <r✓/ VVV 111 :�' 0.00 Fa-WNer 15.97 t2 0 0.62 Tae 1 TOTAL 0.00 . Suaew- 57.29 1.2 0 - 0.62 - 746 7 8 aIrrou ei 4 0.9 oa00 4 modM h TOTAL 0.00 TO7At •di0 5+ason Zonal Eto oat Na coma4wr Fatlas [-aurorrt Plamm�i9a9on Systdn Type•' Zone trr.Efl. Area Sersolwl Play Factor. ha-wtaar 75.97 7.2 0 0.@ 746 1 Waterfeatttre 4 1 0 12 Man PIaTNIgl7gaDon System type; Zone Irt.Elf. Area _ Seasonal Plats Factor. Total Waerteamre 0.00 TOTAL 0.00 PladArcigaTfon System Ttrpe: Zane hr.Efl. Area 9tasorw High Pbot Factor. TOW Waterfeture 0.00slor vow. Few R osz 74B MER waause Plala,*11fion System TYPO Zone Irc EN Area 9aretal Galt Factor. SpraWBrnal 90 4 OA Oa00 5 s 2ale, 0.85 0 Osi 7as ...0.9 s•aa Zo o F+eror Nero CaawrderFa a Esrrrd SpravBu[NID 4 0:9 0.000 5 NI h. 46.02 SPraYl9ubIVrI0 4 OA 4s00 5 Verb Fads ¢ 0s2 746 MEp. waleure ^.arytt 0 0.@ 749 0.9 .¢ o.@ Tea M.F1r. W-Urn Esemyed Total Estimated Water Use swat Zonal Ho Pest Nat Salpare Total Waterteature 0.00 seaaa Zonal Eto Pia Nat Esarram `v swear s7.29 D:ss - swan zonal Et. aaa Area Total Estimated Water Use 39.44 r-r-w.e. 15.97 0,85 0 0.62 749 0.9 aPrag 20.69 1.2 0 aR 748 1 vaare Farax so_R o.sz T48 Inv.Ea. WamrUse o psi 748 1 `Aiwa fadrr era¢ 0.62 746 MEa. warty• Total Estimated Water Use 60.44 20.8s 0.8 0 TOTAL pgp Surrr 5729 1.2 20.69 0.8 0. o.@ T48 0.9 20.69 0.8 0 asi 746 0.9 &near 57.29 0.8 0 oat 746 0.9 fib-Warr 15.s7 1.2 0 osz 746 1 Fae.Wit,r 15.97 0.8 ° oa2 T4a 0.9 TOTAL 0.00 serener 57.29 0.8 0 0.82 746 0.8 57.29 0,8 0 0.62 Ter 0.9 Fat_NMu 55.87 0.8 0 O.eZ 748 0.9 Q0D Fa4yar 15.97 0.8 0 0.82 746 0.9 i TOTAL 0.00 PlantArthalion System Type: Zone Irt.EYf. Area seasgoaPlaMFador. Total Waterteamre 0.00 TOTAL _ TOTAL 000 81 l�oi 32l Approved By. 9WadBubfOdD 4 _ OA 0.000 S NI h f soaaa Zonal d Pro Na no0i4 Total Estimated Water Use 48.12 r PlanVtrc10a0orr System Typo: Zone In.Efl. Area seesaw Plant Factor. ; vdai Factor sat¢ a0 746 ad.I6T. woes ua. PbmNNaaffon System Type' Zone br.Efl. Area __ Seasonal Plats Factor: Ptudgladatim System Tyne: Zane br.Edf. Area Seasonal FUN Factor. SpraWBob0ft -4 '.'0.75 0.000 6 Low Tree 1=1 0.8 0 Ow 746 0.9 a 16t1ItfDrtp 4 0:75 7s 389 6 LOw Tree 4 :0.75 4TAN 5 L4tw Tree ENAL Zorw Edo Peal Nat 2FZgME-rs E•erM4 sooty 57.29 0.8 D osz T48 0.9 sewn Zonal Eto Pun Area emelsrn Faays EsemamA S•mn Zonal Eto Prr Nat Fedora Eanwbd dverb Fade R psi 74e M M. WarUwr� Fab 41111tr 7$-97 a.3 0 0.@ 744 a.9 Value Fxw .R Oat T4B an.Efl- WamrUse vrw Few R acz TO M6R Wear ua. 120.69 0. 0 0.@ 74a 0.7 T 0.2 79.38889 os2 Toe 0.75 0.36 a 5728 0.2 0 og T46 0.75 x+ NORTH 0.00 20.68 Saliq 20.69 0.2 47. 092 Ter0. 4. ^c Date: 17 TOTAL Sews 6728 02 79.38888 a.@ Tae 0.75 1A1 &iwrw 5729 02 47.65 ob2 M. 0.75 0.80 1 15.87 0.2 0 0.62 748 0.75 'te •r I , .000 Su-r PlaaArttaallon SvsLPm Two• Zone Irc Fat Area Sason+i Plea Factor: r6•w ur 15.ff7 0.2 79.38889 0.62 Tee 0.76 028 ! F.a"ywar 15.97 O.Z 47.65 oei 748 0.75 0.99 0.00 TOTAL 1.65 i TOfAI 0.8e SpraNaublDrtp s - 0.75 40.NT 6 Low Tree i PfaMArtioaabet tan mreTwo: Zone Irc.75 Area 8worolPWM d T Swat Zonal Lt. Plat era cat-areFacers Er:wba PImWItNgadon System TVoe• Zan Irt.EYr. Area __ Seasonal PUM Factor: PWMllrtioaNwt SYPtF4n Type: Zone Irc.Lcff. Area 8easorW Plod Faelor: 8pray/BuWDA 4 0.75 OAW 7 Low/Mod Tice year Fact R a@ Tae aa.Fs, wow ue• SpraytetmJDrlo 4 0.75 0.000 7 Low l Mod Tree 4 • 9.TS OaeO 7 Latest Mat Tram Season Zeal Eto eras Nat cowaa;a F:rirs Ewnatea 20.69 02 40.41667 osz 74a 0.75 0.18 _ sear Zonal r3o Plat Ain ranagln Faros Esanraa4 Verb Fader n. psi 748 ME6, wwrpoe Scale: Swag Swm Zonal Pro Nee Comaztn Fa:ps Esrmamd Sumw 57.29 02 40.41667 os2 74d 0.75 o.5t vyae Fatty ,R. 0.62 iae ay.Er. weer use Yob feller -R psi T46 MFa. Vf4rthe ! Spina 20.69 0.35 O o� 749 0.75 -_THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT i Fr4Vibr 15.87 0.2 40.41667 0.@ 74a 0.75 0.74 - sP=g 20:69 0.35 0 os2 Tae 0.75 20.69 0.35 9 0.@ 746 0.75 Suww 57.29 0.35 0 0.@ lob 0.75 toTAL o•� sumac 5729 oss o 0.62 748 o.7s s7.29 °.35 D db2 746 o:Ts Far4rata t5.97 o.3s o a@ 74a 0.761IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, Plantn S Zone Ia. Area sawrwPbnt.FaCiOr. Fa-WMa 15.97 a.3s D 0.62 7,6 0.75 a-mrr ts.s7 1, ° 0.@ 746 o.TS "TOTA1 °'00 SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn By: rrlgatwn Y6tattTwa: TOTAL 9.oa TOTAL D'00 PfadfirtkWOMSMraulr e:. Zane I".Eff. Area Sea"'aalPWOFaebr: IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). I Spravillso rW7P 4 0.75. OAN 7 Low l Mod Tree ease Zonal Flo Pit Na Cana&mF was Fspda4 PIaMMrgaf7ottSwtem Twr Zate Irt Efl Ma 8eatan[PbW11 True SPrayIBuWDdP 4 0.75 117.8T1 8 Mod Tree ��� vales Few .R 0.@ ]46 br.Ell. WamrUse PlamMiaMlon System TYPe' Zone hr.171'. Area SeasonalPbMd re ,4praWart6lWip 4 -0.75- : 14LtK0 B Mod Toe 0 oat Toe 0.75 I SpraviaublDrip 4 0.75 3s.ea4 8 Mod Tree s_sen Zonal Eto Ptah Na carasurFades EairnW SPrtIP 20.69 6.35 swm ZonalEro era M.a ee,arumfader: Fssnra Yrw rroder R asz Td6 ell-ER ,l�,r„w APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO Job No. scan zanalEm Pmd Mao A Fauars ea 0.5 11T.67T4 UM 746 0.75 1.35 ENCROACH INTO DISTRICT AND USBR RIGHTS-OF-WAY. TREES, PLANTS WALLS AND F-� a•rrar 20.69 0.3s 0. 0.52 746 a-7s +"�• ¢ am 746 """"e' 57.29 0.5 117.6774 a@ 7N 0.75 3.73 PERMANENEi• STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR iNS'fALLED IN C.V.W.D. � 401 O �-j Le emu. } Fa6-War 1597 0.35 O Oai 7� 075 a Value Face .R 0.@ T46 Im.FA. WamUse 1 _ 20.89 0.5 142.95 O.BS 74e 0.75 f.83 TOTAL 0•w srnarlar 5069 OS 39.69444 osz Tae 0.75 Ode m4aaa 75.97 0.5 117.8774 0.@ 749 0.75 6-tOt4 11 Sumr 5729 0.5 t4285 a62 740 0.75 4.W Irt Eff Mao saatorw Plat Factor. Par vvamr t5.97 0.539.6944d os2. roe O.t5 0.35 rya-v4arr 15-29 0.5 14ZO5 a@ 746 o.7s 7.2s AND USER EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT W r pianNrtlgation5Ys/amTmw zone Zoe TOTAL 7.42 PERMIT FROM C.V.W.D. �y Y:.`, SPraWauWOdP 4 :0.75 At- 8 Mod Tree TOTAL � CV �r�v Saasen Zonal Et0 PmM Nw Caw•laprFare, lawn Sheet No. ^�. t� l Yana Factor R OM 748 Mgt wiw Uro FKE/■ 20:69 0.5-80.83333 os2 746 0.76 0:92 suety 57.29 0.5 80.83333 0.@ Ter 0.75 2.56 DATE l Fi444r 75.9T D.5 80.83333 0.@ 746 0.75 0.7t p B WATER MANAGEMENT SPECIALIST cc TP-1 i TOTAL 'L� o PLAN � V�ATER GALC.,,,ULATION PLAN V�ATER C,,ALCULAT10N DEVELOPMENT SERVICES SUPERVISOR ATE C.�ALC.,ULATION PLAN I ATE �ALGULATI ON i ul ca NOTE IF NEEDED r= i • STAKE SINGLE TREES 24"BOX AND SMALLER.REMOVE NIMI t* STAKES. • IN TURF AREAS LEAVE A BARE AREA p� APPROX.4"AWAY FROM TREE BASE J IN ALL DIRECTIONS O f "._ ``-•r,.,,, *DO NOT STAKE hR1LTl'S,UNLESS NEEDEDQL •� � I CINCH TIE5(2 EAGW 00 NOT - OVER TIGHTEN,ALLOW TREE TO .p ts) I MOVE SOMEWHAT To BUILD N CALIPER. NOTE' DEPRE55ED WATERING BA51N {PLANT SHRUBS MINIMUM OF 3' FROM TO REMAIN DURING PLANT 1 CURB IN MEDIAN5,2' FROM CURB/51DEWALKg E5TABLI5HMENT PERIOD. Q Q Q a Q E 21/2"�LODGE POLE p1Ne IN PARKWAYS I TREE STAKE(2 EAGW .� 13AGKFILL MIX PER 5PEG5. `� E,..,,�« i SET 2°To 4"ABOVE GRADE � �w SET ABOVE GRADE 2" TO 4" DEPRESSED WATERING BASiN REMOVE FROM TURF AREAS o FIN15H GRADE DURING FINISH GRADING. IIIIIIIIIIiI IIIIII111111= FIN15H GRADE = IIIII NOTE: IIIIII=IIIIII IIN0=IIIIII= — — ROOT ZONE IIIII= _ =iIII i IIIIII= UNTANGLE MATTED ROOTS BY BACKF ILL MIX PER SPEG5. IIIIII_ — LOOSENING ALL ROO _ i luiil 11811= Se SPECIFICATIONS, T5 — IIIIII R EDGE o C 1/ N H05E. DO NOT CRACK ROOTBALL. rn 00 I - Illifl� i =I =I =IIIIII NATIVE uND15Tt1RBED SOIL — — OF ROOT BALL w/WATER FROM �4 III I_III II-�lii i=111 i _ - 0 111111 9 NATIVE UNDI5TURBED 501L FOR PLANT PIT517E R�ER ^ I 3X R007$ALL TO SPECIFICATIONS. 3X ROOTBALL E`�, N � U 7 TREECM J PLANTING W/ DOUBLE STA< 1 NCG o a cQ c A SHRUB PLANTING N.T.S. B �� (0 > `° N.T.S. In E = ti n O PLANT PALM 50 THAT � � = N c AXIS 15 PLUMB - 0 _ oo a 8'-12' VARIES o VERIFY W/ LANDSCAPE DE-51 GNE-R I 12 GAUGE GALVANIZED WIRE TYPICAL ` _ FAI NT N T WIRE TO MATCH WALL ATTACH WIRE TO WALL WITH GALVANIZED SCREWS (TYPICAL) Q "q � PAINT SCREWS AND WIRE TO MATCH WALL P Q c SCREWS TO BE SPACED AT A PLANTING NOTES MAXIMUM OF 6'-0" ON CENTER H i i. Before any plants are planted, all planted areas are to have been graded - 9 p Q q (� �----- TRAIN PLANT ACROSS WIRE TO if Q Q�CtG' in an acceptable manner to asssure positive drainage per the grading notes. P FULL HEIGHT AND WIDTH W 2. Separate all shrub/ground cover areas from lawn areas with 2'x 2' redwood headerboard or 3 layers of redwood benderboard with staggered ,joints °O Nor PLANT LOB Tt�aN row W (refer to planting fans). of ROOT BALL OR TOP of Roar r a TER-si:nle �.T.� Stake �� t3 p g ke headerboa �- P _ Q A p rd with I x 2 x 12 redwood NOT TO BE LONER THAN FINISH GRAVE "` stakes spaced 48" on center maximum. � � 3• Plant shrubs a minimum of 30' from all landscape light fixtures. "" FIN 1 SHED GRADE 4. Where circumstances permit, plant no tree closer than la, to an edge of _ RADE paving or headerboard. _o - -I i -11 I 5. Remove all stakes from vines =I � w 6. Refer to plantingg details. _ E-y O I. Whenever possible, use plant materials acclimated to the Coachella Palley. 8. Landscape contractor when tying vines is to use a drill to establish the pilot hole to receive the red-head portion I of the molly. NOTE: ESPAL i ER TO BE TRAINED !N A FAN � 9. When tying vines or espaliers, wires shuld be spaced as follows: let (2) SH ,�I at i'-6" apart from finish grade, the next (3) at 1'-0' apart to make APE 41 � 1 the top wire at 6'-0" above lint uNVls j finish grade. Wires should b TtV NATIVE sole �+ M g e a minimum of TO PROVIDE FOR FULL WALL COVERAGE 040j 8-0 long center on plants. When vines or espaliers are closer than leoor$,al.l_ UNLESS NOTED OTHERWISE � W � ! 10' apart, use a continuous wire between both plants. 10. For protection of trees in turf areas leave a bare area approx. 4' away from tree base in all directions. For pl ant pit size refer to specs. ^^ I H ii. WARNING Plant material listed ma o rT� y r may not have been approved b W the Agricultural Commissioner's office. landscape contractor, please PALM TREE PL.ANTI NC9 � contact the developer for status of Agricultural Commissioner's approval C ESPAL. i ER TRAINING DETA or dental. Plant material not conforming with quarantine laws ma be N.T.S. destroyed and civil action taken. All plant material is subject to D mow inspection at the discretion of the Agricultural Commissioner's office. N.T.S. M All plant material must be free from Red Scale (Aonidiella aurantii). r Fit 12. No shrubs are to be planted within 18" of hardscape, measured from center rl OF shrub, PALM TREE PLANTING NOTES #^�G u tt'�^� 1. Palms shall be planted using established planting procedures. Refer to LANDSCAPE INSPECTION S�HEl�ULE palm tree planting detail. Q 2. Palm tree root balls shall be trimmed or cut to ensure recovery from t o H transplanting shock O FIN15H GRADE 3• Palm trees must be in a healthy condition at time of delivery Palm a- 1) Sleeving / Crtrading trees determined unhealthy or damaged at time of delivery or installation X shall be rejected by contractor anc; replaced by subcontractor at his m a. Sleeve diameter, type depth and location ) expense. b. Soil surface drainage, elevations and trash C including weeds 4 rubble) 4. All palms shall be cleaned of excessive dead and ragged fronds or frond � stubble. Cut fronds should be cut to a maximum length of 6'. Z IIII= 2) Harder-ape / Boulders / Cobble 5. Ca I led out heights of pa ims sha I I be THE HE IGHt FROM TOP OF ROOT BALL TO BOTTOM OF LIVE FRONDS. t" IIIII . Sidewalk and wall layout 6. Palm trees to be properly watered in and soils properly tamped around the — _ IIII a a. Utilities location root balls when planting, leaving no voids of soft around root balls. m = _ =IIIIII—II C. Boulder tape, size, weight and placement I 'i. Pa im trees shall be planted vertically, unless noted otherwise. �' I� = IIIII --III II_I IIIIII= ALL CAVITIES AND VOIDS 8, trunks should be rough with frond bases still securely attached. 3) Irrigation system - ROugh-In S. Trunks may not be totally skinned unless noted to do so. SLOPED GR /t fi-� ARE TO BE BURIED 0 I 10. Trunk bases may be skinned to a maximum height of 3'-4' (taller trees 6') l'tl.i a. Trench depth and location "" I It. Skinned areas above the 6' level will be accepted, at the direction of the Q b. Wipe size and Glass O Landscape Architect. c. Pressure test C125pel for 6 hours) 1 12. Care should be exercised in the cabling during transport and planting so as � I not to damage or loosen bark X � i 4) Plant Material (trees t shrubs) U 13. Severe cracking or holes in the basal trunk area will not be acceptable. w FINISH GRADE a. Condition 14, One initial watering will be performed by subcontractor. Basin will be left t!) I b. �T��yype t on each palm so subsequent watering can be performed by others. Basin t�V G. PTaGement W is to be removed during finish grading. I 15. Subcontractor to untie frond tops (ro0) days after plantinr�r� Z 16. Palm trees shall be planted a minimum of 18' away from butfding eaves. 5) C-troundcover (decomposed granite) 1'T• it is recommended any palm tree planted within 5' of any walk, wall or 1 j IIoIII= =IIIIII a, T to protect pe I structure t against root damage.planted with Deep Root root barrier to a depth of 2'measured minimum _Io=IIIII_ c. Compaction b. Uyepth and spacing � _ IIIII=IIIII —IIIIII m 16, Washingtonia robusta trunks are to have a minimum diameter of 14" O 4' high on trunk above finish grade. O I GRADE IE ALL GAVIT5 AND VOID5 6na I NOTE. LEVEL ) Ff o M NOTE: ARE TO BE BURIED a. irrigation � M NO PALM TREE SHALL BE OUT OF THE ORIGINAL GROUND POP, MORE THAN BOULDER5 IN GLZTER5 ARE 1 I) Valves, boxes and wiring (48) HOURS PRIOR TO RELOCATION AND PLANTING. if) Controller operation and schedule 'o TO BE SET AT VARIED HEIGHTS lit) Sprinkler, bubbler and/or drip emitter type, flow rate and quantity per plant T`i'PIGAL BOULDER PLACEMENT iv) Overall operation E vl As-Built � N.T.S. c. Overa Ij b. Tree stakin I g �®ULDE ��HEDULE W QUANTITY: a SY PLAN I PLAN 2 PLAN 3 PLAN MBOL SIZE APROX. WT. I i i i L I TT iN LEGEND 5`x4'x4' I-I/2 tons AN1QUAN2 3 NQU • aUANQUA . W Q I SYt-1. FIXTURE LIGHTICOI"Il"CENTS � 2 O I 4'x4'X3' ± I ton i 2 i i 120JVOLT,WIITTHILIG44T SS}•{JROUDC 32 WATT PLT ACCENT LIGHT FOR PALM TREES 4 a MOUNT ON NADGO ROCKET PEfs!"IA-POST VINES ON WALLSW/SLACK FINISH Approved By: G OJ'XOJ'X2' ± 5/4 ton I SPJ LIGHTING INC - SPJI6-01 D 42 WATT PLT BASE I NI=ORMATI ON i i 120 VOLT,WITH LIGHT SHROUD UP-LIGHT FOR CANOPY TREES O 2 B'X2'X ± I/2 ton PROVIDED MOUNT ON HADCO ROCKET PERhA-POST W/BLACK FINISH BY: JHA ENS I NEERI NG, INC. NORTH I I � 2' Date: THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA V Scale: LfCx�-ITINC: SETBACK NOTES IN ACCORDANCE WITH WATER CO ALLEY WATER DISTRICT Underground Service Alert LANDSCAPE DESIGNER GA LIGHTING DE TITLE 7 Dlvlsl GHTINCs NOTES: ON 1, CHAPTER 3, ARTICLE 10.8, NONE NNOT AS RE5PONS151 -1TY f=CR' Locate light fixtures a min, of 4'-0" from edge of tree. TREE 4 PALM LIGHT FIXTURES SHALL BE ON SEPE SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN OR ANY PLANTS UT i L I ZED ON 51 TE WH i CH ARE IN COOPERATION WITH THE LOCAL GOVERNING Drawn By: NOT SHOWN ON THE Locate light fixutres 1'-0' from ed a of alms. CIRCUIT RATE AGENCY (CITY OR COUNTY). Call: TOLL FREE. g p SAND ON PHOTOCELL ON/OFF. APPROVAL OF THIS DRAWING BY C. . ��II-f or ENCROACH INTO D V W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO PLAN SAND HAVE NOT BEEN APPROVED BY THE AGRICULTURAL At all times a conscious effort will be made to place DISTRICT AND USBR RIGHTS-OF-WAY. TREES, PLANTS WALLS AND Job No. 1-800 PERMANENET STRUCTURES OF ANY KIND MAY NOT COMMISSIONER'S 01=FIGE. light fixtures in planter beds instead of lawn areas. AND USBR EASEMENTS OR RIGHTS-OF-WAY WITHO BE EFIRST OBTAINING AN ENCROACHMENT Q C7 �a 2-4133 PERMIT FROM C.V.W.D. EU These measurements are superseeded only when field 010 > TWO WORKING DAYS BEFORE YOU DIG conditions warrant change by Landscape pesigner. Sheet No. DATE BY UJ Cc WATER MANAGEMENT SPECIALIST TP-2 1 r DEVELOPMENT SERVICES SUPERVISOR © I I r ILIEMITTER 1) SCHEDULE «� o TREES r= ANT / J SYM. NAME 51ZE EMITTER QTY. QTY. QTY. QTY. U5A6E F KATER TOR Acacia smallll 24" box Ralnblyd 1402 1 O 0 O L Sweet Acacia 0.2 N , c � I I ■ --- DRIP ZONE -- a Acacia aneura 24" box Rainbird 1402 O 1 1 0 Mulga L 0.2 " 0 _ Gercidlum f. 'Desert Museum' o ' DRIF ZONE 'jC 24 box Rainbird 1402 0 1 0 0 _ - Palo Verde L 020 v 1 1C I❑ I I i ! I BM 3/4' DRIP I I I�I Oleo Euro ea 'Swan Hill' 9 - f © p 24" box Rainbird 1402 1 O � Q I BM I (� -( Fruitless Olive I I M OS •� 0 A 3/4' DRIP I � 0 + I CCrRO1.LER , 5chinu5 Moile 24" box Rainbird 1402 O O M 0.5 - 2C - - I Pepper Tree O I G - m 12 ' - 2C >~ QQQ Q Q 3/4 TREE I I 3/4' tREE _ TION I I I X I PALMS �. ��. �� ��� -- - C.0 LEi� I ❑ I r---, _ _ C-7 I - - + 3C 2,r� - � Q` eti f I110 i 3C I I _ PLANT = 2.5 C t13 - - - -�- -I- --' � �_ �� a 3/4' PALM - , SYM. NAME 51ZE EMITTER aTY. aTY. an. aTY. us�� FACTOR i� 3/4' PALM - - - n \ I / Ghamaerops humills 24" box Rat 0nblyd 1402 I I 2 1 M 0.5 Mediterranean Fan Palm 7 7I _ - - - - - - 1 - / _ I ( _ ® Washin tonta hybrid see plan Rainbird 1402 2 2 2 2 H _ _ - - - - - - - I I // 12 n ,A\ - Hybrid Palm 0.8 ti I �r • \ I I 10 ! ° LEEVE _ 0 • • O \ �-{� z SHRUBS �,��` �� � �� 1 Q o I / O\ i- e Q ` Ch Z _ \ ti + i` 77A- - - - - - SYM. NAME 51ZE EMITTER OTIr Q WATER PLANT u1 C o a _ _ TiT TY. QTY. (STY• U5A6E ACTOR N I - � If i BM BM � � I BM ) BM ,.,��12 II \ - - - - - - - _ -f 1 O \ Oj - r Balleya multiradiato 3 4 v VE BM I gal XB-20PG-1032 5 3 L 0.2 x 0 Desert Marigold < _ E CL CD I Bougainvillea rosenka E 5g al XB-20PG-1032 3 2 1 2 M O.5 ro ;_ Bougainvillea Rosenka to o N O Galiiandra californica 5 gal. XB-20PG-1032 1 2 3 3 L 0.2 m Baja Fairy Duster Gaesalpinea pulcherrima 5 gal. XB-20PC-1032 O 1 O 1 Red Bird of Paradise M 0.5 = $ -� U o Cassia nemophila � � a~o a DRIP ZONE5901 XB-20PG-1032 I 2 3 I I �.O.G. 1�.0•G. Green Cassia L 0.2 M u DIF?iP ZONE �� Lantana montevidensis 'Purple' I al XB-20PG-I 3 5/4 RE51 DENT1 AL METER- ' `- Pur le Trailing Lantana p g O 2 ' I 4 I M 0.5 5/4 RE51 DENT1 AL METER- ••�. �. �. O p g Lantana montevidensis 'New bold' I gal X5-20PG-1032 5 6 4 4 M j PLAN 7'rFE New bold Trailing Lantana O.5 NORTH 7"rFE , + Leucoph Ilum frutescens Green Cloud 5901 XB-20PG-1032 NORTH Green Cloud Texas Ranger 5 3 3 5 L 0.2 Mulenbergla rl ens 5 al. I M 0.5 Deer Grass g XB-20PG-1032 4 3 3 O ORuellla peninsularis 5 ga1. XB-20PG-1032 3 I 3 I L 0.2 Desert Ruellia � u1 I - 01 i i Q I � ear° a DESERT ACCENTS �` �`� �� �°` cL'1JJA;7RIA9J O --- -I DR E WATER PLANTSYM. NAME 51ZE EMITTER QTY. QTY. QTY. QTY. U5A&E FACTOR Agave vilmorinlana 36" 4P XB-20PG-I032 1 1 2 1 I I - Octopus Agave L 0.2 1 I ® �`✓ � -� �� DRIlz�ZONE - I 0 �C � � DasyUrlon wheeled 5 GAL. XB-20PG-1032 I I I I 3/4 I - 1 El 3/4' Desert Spoon L 0.2 DRiP + Hesperoloe parviflora 5 GAL. XB-20PG-1032 2 3 1 2 L 0.2 DRIP - � 2C ® + _ _-� O Red Yucca I , leiH w = 3/44 TREE 'I� I I 2C 2 VINES ��� []11 0 ° 12 I I i 3/4' REE _ IPL® 'T ® SYM. NAME 51ZE EMITTER QTY. arr. aT U�5 A�CeTER FACTOR ANT - 3C 3 - - - - Y. OTY. 3/4' PALM ❑ ❑ 3C 2.5 1I Bougalnvlllea 'Barbara Karst' 15 6AL. XB-20PG-1032 1 O O 1 3 X -' �, - Bougalnvlllea M O.5 3/4 PALM ° ° I ° _ Galiiandra inaequllatera 15 6AL. XB-20PG-1032 O I 1 O M 0.5 Pink Powder Puff r i Z - W - - - - - - - + - - - rn I- SLEE { I _ _-_ _ _ ❑ C - �= + - - - - T I X REFER TO SHEET L i -2 FOR iRRIGATION DETAIL5 and &FECIFiCATiON5 3 - 4r SLEEVE I I 1� / 1 I BM I - ,. I -+12 " , i F , - - Underground Service Alert j f BM \ ID rn v Call: TOLL FREE 1-800 H ��\ �\ 1\ ❑ D+ 1 BM \ 'a,. • a M \ I I 422-4133 eM 1 IiL TWO WORKING DAYS BEFORE YOU DIG r ' LEI \ \ X / j O GERALD FORD DRIVE Cd 5/4" RE5IDENTIAL METER- I .� - 3I4 RE51 DENT I AL METER- _ PLAN T'�FE 5 NORTHFLAN 7"rFE 4 z: NORTH < F AN I ,� LIGATION LEGEND W olo I 1 C�IUJD UJ,�TE i� C,��CS FLAN 3 � z GVWD UJATER CALC5 O } a M A.A.W.A. = 93.9 x 6 x 1,455 x .62 / 148 = 6`1.95 GCF MA.A.W,4. = 93.9 x 6 x 1,9ID6 x l02 / 148 = 89.01 GCF SYMBOL MANUFACTURER MODEL NO. DESCRIPTION NOZZLE RADIUS FLOW PSI PATTERN FRANK 51NAT '~ GPM RA DRIVE . M a LOW WATER USING PLANTS---- E.A.A.W.A. 93.9 x 2 x 121 x .62 / 748 / .9 =-12.51 GCFPLANTS LOW WATER USING ---- E.A.A.W.A. = 93.9 x .2 x 1,,a48 x .62 / 148 / .9 = i8.13 CC1= RAINBIRD 1400 SERIES TREE BUBBLER 1402 0.5 GPM 25 FULL ��T� � •� MOD WATER USING PLANTS---- E.A.A.W.A. = 93.9 x .5 x 641 x .62 / 148 / .9 = 21.98 CCF o MOD WATER USING PLANTS---- E.A.A.W.A. = 93.9 x .5 x -(63 x .62 / 148 / .9 = 32.99 GCF DRIP ZONE RAINBIRD p p., HIGH WATER USING PLANTS---- E.A.A.WA. = 93.9 x � x 81 x .62 / 146 / .9 = 4.eO CCF HIC�4-I WATER USING PLANTS---- E.A.A.W.A. = 93.9 x 7 x 95 x 62 / �48 / Ti = 5.�5 ccF XB-SERIES DRIP EMITTER XB-20PC-1028 - 2 GPH 30 - © CCF W TOTAL ESTIMATED WATER USE = 45.45 CCF I TOTAL ESTIMATED WATER USE = 56.8i CCF RAINBIRD ESP-6LX+ WALL MOUNTED 6 STATION RESIDENTIAL CONTROLLER. LETTER DESIGATION REFERRS TO PLAN TYPE ONLY �1 ca c� A "ASVF" SERIES T I I A RAINBIRD W/ XACZ-075 ELECTRIC CONTROL VALVE FOR DRIP AREAS, SIZE AS NOTED ON PLAN W/ RBY FILTER & +30psi PRESSURE REGULATOR NO SCALE I �'1�AN 2 CVUJD r„UATER C,��.CS �'1�AN 4 CVWF,) L'4TER Cy4LCS RAINBIRD ASVF SERIES ELECTRIC CONTROL VALVE FOR TREE BUBBLERS & LAWN, SIZE AS NOTED ON PLAN BA5E I NEORM4 ATION PROVIDED JL�,A.A.W.A. = 93.9 x .6 x 1,429 x .62 / "148 = 66.73 GCF 93.9 x .6 x 1,216 x .62 / 148 = 56."19 CCF 5.r; JHA ENG f NEER I NG INC. a Q LOW WATER USINGPLANTS---- E.A.A.W.A. = 93.9 x 2 x 154 x 62 / 148 / 9 = 1304 CCFPLANTSH KBI #MIP-1000-T BALL VALVE (LINE SIZE). REFER TO DETAIL ON IRRIGATION DETAIL SHEET LOW WATER USING ---- E.A.A.W.A. = 93.9 x 2 x 66'1 x .62 / 148 / .9 = 11.54 GCF MOD WATER USiNGs PLANTS---- E.A.A.W.A, = 93.9 x .5 x 596 x .62 / '148 / .9 = 25.11 CCF MOD WATER USiNG PLANTS---- E.A.A.W.A. = 93.9 x .5 x 4-11 x .62 / '748 / .9 = 20.31 CCF p., HIGH WATER USING PLANTS---- E.A.A.W.A. = 93.9 x I x I9 x .62 / 148 / .9 = 41B CCF PRESSURE MAINLINE PIPING USE SCHEDULE 40 - 3/4" MAINLINE NICx+-I WATER USING PLANTS---- E,,4,A,W,,q. = 93.9 x .� x �8 x .ro2 / �48 / .9 = 4.�2 CCF Approved By: TOTAL ESTIMATED WATER USE = 43.59 CCF NON-PRESSURE LATERAL LINE PIPING - PVC CLASS 315 FOR DRIP, TURF AND TREE BUBBLERS- ALL 3/4" LATERAL BACKBONE p TOTAL ESTIMATED WATER USE = 36.63 CCF GIRA _ HIC SCALE ��8 a=�1-0° NORTH Date: F IRRIGATION POINT OF CONNECTION - RESIDENTIAL 3/4" WATER METER SOURCE. 1.2/1/04 Scale: OTE' THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT „ L+ /� //'�� GJ�j /�' PIPE SLEEVING SHALL OCCUR UNDER ALL MAJOR HARDSCAPE. SLEEVING SHALL BE 4" DIAMETER PIPE. IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, s m� L I RR I CST I V N JT-fON O� T�"�I��„�" L, � I S IL7MT I I �,/ SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn : -' G ONL I . iN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). y NSTALL ALL MA I NJ..- I NE, LATERAL, VALVES AND ANY OTHER INDICATES VALVE STATION & CONTROLLER NUMBER APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO FJH ENCROACH INTO DISTRICT AND USBR RIGHTS-OF-WAY. TREES PLANTS WALLS AND Job No. 550G I TED i RR I GAT I ON EQU I 1�ENT I TH I N THE L 11�I TS O �. NDSG fi�E ,� ,� PERMANENET STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR INSTALLED IN CN.W.D. -3 �a `- -INDICATES FLOW IN GALLONS PER MINUTE AND USBR EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT 4010 � `-5 iva PERMIT FROM C.V.W.D. > � as INDICATES ZONE TYPE Sheet No. Ct! cep DATE BY cv INDICATES ELECTRIC CONTROL VALVE SIZE WATER MANAGEMENT SPECIALIST TT j ._j o 1 1- DEVELOPMENT SERVICES SUPERVISOR .a u a' C) N 1.00 IRRIGATION SYSTEM SCOPE OF WORK A.Work In this section includes providing all labor,material D.The Irrigation material shall include but shall not necessarily 44.00 IRRIGATION SYSTEM INSTALLATION PROCEDURES: I. ROUND VALVE BOX WITH GREEN BOLT- 1 2 3 1 2 3 c equipment,tools,permits,and transportation necessary to be limited to the followings: DOWN COVER -(TAN IF IN SHRUB BED) A. Irrigation plan Is d m lagramatic. Irrigation laterals and mainlines HEAT BRAND "BV" ON tarnish and Install a comploto Irrigation system with 100% 41 o coverage of designated areas shown on the drawings and I. PLASTIC PIPE: shown In hardscape Is for clarity only. Install all Irrigation VALVE BOX COVER IN 2" HIGH LETTERS. clfled herein. Extended from 100%virgin I chloride (PVC). equipment In planter bed areas. Landscape Contractor shall }'� 1 a 9 Pottivt J vorl yl actual location of power source and controller before 1•'1Y 1 ID TAG p 1 ID TAG N v Outside diameter of plastic pipe shall be the same size any Irrigation Installation. i'� I 2. FINISH GRADE. 2 WATER PROOF CONNECTION 5.The work shall Include but shall not be necessarily be limited as Iron pipe,with plain ends, All pipe and Pitt" /� 2 WATER PROOF CONNECTION •� to the following unless spocifled otherwise. shall be In accordance with the Society of Plastic 4 (1 OF 2) Contractor shall visit the construction site, y S.tnstott att a titers and trod bubbtwo on uphitt aide of plant T 3. FULL FLOW, BRA55 BODIED BALL VALVE- FULL PORT 4 1 OF 2 I.The Landscape Con Industry Standards. material. Emitters shall be install one (29 above finish grade, 30-INCH Ltf6COI LE45GT4i take all measurements,and obtain any other Information 3 30-INCH LINEAR LENGTH � � � any emitter left at an unacceptable height shall be reinstalled PLAN I 5 OF WIRE, COILED 5 OF WIRE, COILED Q Q, necessary for a complete and conclusive bid. b. Pipe shall be continuously and permanently marked with of no cost to the owner. 4. 5GH. 40 PVC, PIPE EXTENSION, DIA. TO ALLOW O REMOTE CONTROL VALVE: O REMOTE CONTROL VALVE the following Information:Manufacturer'a name,normal pipe FOR MOVEMENT OF HANDLE ON VALVE s - 6 RAIN BIRD ASVF $ - 6 RAIN BIRD ASVF Q Q a a a 2.Ordering,furnishing,and installing materials for complete size;PVC,type,S.D.R.or pressure rating;and extrusion C.Verify actual quantities and final location of plant material = _ _ LENGTH AS REQUIRED. - - system including piping,valves,fittings,bockflow proventor with the owner's representative before any installation of the ° O INSTALL 6-INCH MIN. ABOVE t�INSTALL 6-INCH MIN. ABOVE (Unless Specified Otherwise),dripper lateral lines,automatic date. HIGHEST POINT OF DISCHARGE Irrigation system. I I I I 5. 3/4" CRUSHED ROCK - 8" DEPTH. 7 � HIGHEST POINT OF DISCHARGE controller,and final adjustment of lines to insure complete O UV RADIATION RESISTANT 11 s as required to eliminate misting and 3 O UV RADIATION RESISTANT PVC SCH 40 MALE ADAPTER PVC SCH 40 MALE ADAPTER coverage. c.All plastic pipe shall be handle with care and shall be D. Install Ratnbird PC5 screen q 9 6. COMMON BRICK (2 REQUIRED). S. Trenching,stockpiling excavation materials and refilling espectoliy protected from prolonged exposure to sunlight. overspray unto hardscape,streets,and structures. (1 OF 2) (1 OF 2) ooe trenches, Including compaction of back fill and Installation o° o° ° "1. SGH. 80 NIPPLE TOE W/SS PVG COUPLING O UV RADIATION RESISTANT O7 UV RADIATION RESISTANT 8 PVC SCH 40 PIPE 8 PVC SCH 40 PIPE g 6 .;• •' tat (1 OF 2) (1 OF 2) of alcoves. d. Protect all PVG plastic pipe from damage during construction 10.00 IRRIGATION MAINLINE AND LATERAL LINES: o o $o and store ° ° ° 4 8. 2" CLEARANCE. O8 FINISH GRADE/TOP OF MULCH / O FINISH GRADE/TOP OF MULCH 4. Line voltage connections, to the irrigation controllers and 9e -1 0$0 ° o °o ° o low voltage control wiring from controllers to remote control A.Entire system shall be capped and pressurized to 100 PSI and o• 80 0 p. O U PVC SCH 40 ELL 9 PVC SCH 40 ELL shall remain so for a two(2) hour period. Check all joints and ° ° 086 ° a. PVC, MAIN LINE PIPE. (1 OF 2) (1 OF 2) valves. connections for leaks. Repair and correct as necessary. •o t6" 9 t6" 9 - 2.PVC.FITTIN65: _ _ 10 PVC LATERAL PIPE ( 10 PVC LATERAL PIPE 5. Replacement of unsatisfactory materials, o. Plastic fittings shall be of polyvinyl ahiortde(i VC),Type s 5/4" IN TURF AREAS. I O (1 OF 2) (1 OF 2) N B.THE ENTIRE SYSTEM SHALL 5E FLUSHED PRIOR TO INSTALLATION „ to I,Schedule 40,NS.F.and of IPS solvent weld or screwed ° 8 2 IN SHRUB AREAS. 6. Cleanup, Inspection and approval. typo,Lasco,5loane(same manufacturer as of pipe). Where of SPRINKLER HEADS. Wherever necessary,Landscape Contractor o °o 00 0 . __ shall Install anti-drain check valves (primarily on slope areas)to 10 10 pp T. Operational tests. threads are required,these shall be Injected molded and alleviate low hood drainage%rosionp y p q o80°86.--° o go• o �pO80o Sahcdule r* All connections shall be solvent welded. 11 RBY FILTER & +30 PSI PRESSURE REGUI I 80.o$off $00 00°o°o°'o°° rj �- _,�� �J h U � b. "As Built" record drawtnga,shop drawings,warrontlea O J and guarantees. IL00 IRRIGATION HEADS: SECTION °• ° ff°°8°Og° °°g°°° ° 9 b. Plastic to plastic joints shall be solvent-weld joints. E Pipe Solvent shall be Johns-Manville "Slue"solvent weld A.Sprinkler heads alongstreet curbs shall be setback 15" from 41.Verify underground utility locations. c ail street curbing. 5p g ement. Sprinkler heads along Interior sidewalks �' � L i shall be install 4"to 6" from any edge of walks,drive or path. 1�1"tLL � L� ANTI-51 i��-I'ON TREE/LA1 NN CONTROL Y�L�� Q ANTI-5I i��tON XERI GATI ON CONTROL �ALY� � � E � 2.00 CODES,PERMITS,FEES,LICENSE AND INSURANCE: c. Plastic to metal joints shall be with male adapters. the C B ! \ CM` r shall be hand tightened,plus one turn with a B. Irrigation heads on a riser w111 not be permitted along 11 v-V male adapts g ,p N.T.S. A.All work and materials shall be to full accordance with the strap wrench. Joint compound shall be Permatmx Type It fiatwork. Refer to legend for height of all pop-up sprinklers. N.T.S. T.S. CD > _ latest rules and regulations of the National Electric Cadet the Uc may be threaded). Plumbing Code,published b (Only Schedule plasti y the Western Plumbing Officials G. Adjust entire system as necessary, Including locations of the Association;and other applicable State and local Iowa or sprinkler heads,radius of throw,and (V adding sprinkler hoods IP LEGEND L O t0 regulations. Nothing in these Drawings or Specifications Is to S.REMOTE CONTROL VALVES: If necessary for the intended operation and 100%coverage E�- Q f� �. CID 4) be construed to permit work not comforming to these codes. a. All valve locations are shown schmmaticaliy on Irrigation plan of all planted areas. 1. BROOK5 #1100 10"XIO" ROUND VALVE and need to be verified with and approved by Owner's BOX. HEAT BRAND "FV" ON LIP IN 2" Representative/6oneral Contractor. Irrigation valves wt11 not v HIGH CHARACTERS. TAN COLORED BOX � L I D. � � _ � B.The Landscape Contractor shall promptly notify the Owner's be allowed In grass areas unless approved by Owner's \ / _ mm Representative/bonorol Contractor of any work outlined on Representative/eanerol Contractor. 12.00 AUTOMATIC CONTROLLER: �[ �/ C } the plans or speclflcatlons that is not to accordance with 2. FINISH GRADE. O1 FINISH AD DE/TOP 0 F MULCH A.The Landscape Contractor shall be responsible for the final applicable laws,codes,and regulations. Without such electrical connection from the power source (BY OTHERS)to 3. GHRISTY,S I.D. TAG. (SEE NOTES). notice and appropriate modifications by the Owner's 4.VALVE BOXES: controller as indicated on plan. Final controller location UP SPRAY SPRINKLER 2 Representative,the Landscape Contractor shall assume full a.Valve boxes shall be green Carson No.AIO to lawn areas shall be verified with and approved by owner's Representative 4. 3/4" CRUSHED ROCK. 6" DEPTH. �2 - responsibility for any work executed which is contrary to and tan Carson No.4110 in shrub areas. Mark lid /benoral Contractor. such laws,codes,and regulations. "irrigation Control Valve". Install 2" above grade In 3 groundcover areas wherever possible, 5.Attach a typewritten legend inside each controller door,stating 5. AG PRODUCTS 3/4"-B BALL VALVE. 2 G. License: the areas coverod each remote control valve. 6. PVC, 5GH. 40 MALE ADAPTER I/2-INCH MARLEX STREETm All work shall be performed by a 0-21 Gaitfornla licensed ( 2 ELL(5 Landscape Irrigation Contractor. S.VALVE CONTROL WIRE: S 3 7° 5ALGO A/R FLEXIBLE PVC, HOSE a.Valve control wire shell be Installed per code. Marever 15.00 COVERAGE TEST: 3 O PVC LATERAL PIPE possible, loco wire to common trench with mainline. Wire MINIMUM 3 FOOT LENGTH d LEGEND D. Permits and Ins ections: y p P �P O PVC SCH 80 RISERSThe Landscape Contractor shall obtain,coordinate,and pay for shall be UL-approved for direct burial in ground,size A.when the sprinkler system is completed,the Landscape 8. 5GH 40 - �{O DECyREE ELBOW. any permits fees,and agency inspections as required and *14-1 (UNLESS SAPECIFIED DIFFERENTLY ON IRRIGATION PLAN) Contractor,In the presence of the Landscape Architect AAA_ 10" MIN LENGTH I�I i_)III I I I i-I��I=I I I I I. RAIN BIRD XB-#�-1032 EMITTER submit all cert141cates of approval upon completion of work. minimum with maximum voltage drop of 5%between valve or Owner's Representative,shall perform a test which Indicates _ Hil Q• RIGID PVC PIPE. 3 - see emitter schedule for Specific emitter and controller. Common ground wire shall have white the water coverage afforded the planting areas Is complete, ���� 1 adequate,and does not sprinkle any structure walls,walks O PVC SCH 40 TEE OR ELL I I I I= =III(= 2. BOWSMITH POLYFLEX RISER E. Insurance: insulating Jacket;control wire shall have Jacket of color or paved areas. The Landsca a Contractor shall Purnlsh aN I I(_)III III(_)I I i I i I III I- (LENGTH A5 REQUIRED). The Landscape Contractor shalt carry all Worker's Compensation, other than white. Splices shall be made with s200b-S P P I" IN LAWN AREAS. Buchanon s Ilce caps and 3M s35?6 5cotchlok seat k•�, materials and perform all work required to correct any public liability and property damage Insurance as required by p ps P� lnadegvocles disclosed. (III 2° IN SHRUB AREAS. 3. FINI51{ GRADE• `� 4. PVC FITTING (S x 5 x I/2" FIPT). all applicable codes,regulations,and the 6oneral Contractor. q 6 6.SLEEVIN&: 14.00 CLEAN UP: NOTE: USE TEFLON TAPE ON ALL MALE 4 5 5. PVC PIPE (DEPTH PER DETAIL G-ON THIS SHEET). F.Site Veriftcatiorn a. Landscape Contractor shall provide all irrigation • , ° •c ° a Prior to commencoment of work,the Landscape Contractor shall sleeving(Unless Spealfled Otherwise) under all hardscape. A.During construction,the Landscape Contractor shall keep t •° .• + •�,• •°° PIPE THREADS. verify all conditions and dimensions shown on the plane necessary Coordinate all underground PVC,sleeves work with the premises as clear as possible of material and debris. 8 8 oy'e•e °°E••,+, L�� i to achieve the Intended design of the irrigation system. Any Owner's osontative/6oneral Contractor. All sloevin s discrepancies shall be reported immedlately to Owner's required sRholi be Schedule 40 PVC pipe and shall be a g B.Upon completion of the work under this section,the Landscape FLUSH TO BE LOCATED AT THE END 4 5 3 6 Representative/General Contractor. minimum two sizes larger than lateral or mainline piping. Contractor shall remove from the premises all surplus material, OF ALL DRIP LATERALS. tools,equipment,rubbish,and debris resulting from his work, rvl and shall leave the installation site in a clean,neat condition. 6. Coordination: SLUSH V L�l OF-UP 5FRA"I IDETA I L IDRi� FM I TTER A55EMBLY W The Landscape Contractor is responsible for coordinating this E D work with all other trades. This includes,but Is not limited 6.00 IMPLEMENTATION: to,provisions for raceways and sieeving as well as water and nF N•T.S. N.T.S. N.T.S. power sources. All irrigation work shall be coordinated with A.Prior to installation,Landscape Contractor shall verify static and approved by Owner's Representative/6oneral Contractor. pressure at project site. This system is designed to operate from 22 gpm at a maximum static pressure of 65 P51. O/L Notify Owner's Representative/6oneral Contractor at the site H.Scheduling: immediately of any discrepancies and proceed as directed. The Landscape Contractor shall notify Owner's Representative/ &*moral Contractor not lase than two (2) working days in advance HOUSE SERVICE PIPING (D ELECTRICAL JUNCTION BOX of an requested observation. size a5 required y e0. B. If irrigation system is to operate from the golf course,verify all site conditions: grading,static pressure,and point of P.O.G. TO HOUSE SERVICE LINE 2� IRRIGATION CONTROLLER - WALL MOUNTED connection for remote control valves. ROUND PLASTIC VALVE SOX 5 6 LEGEND CONTRACTOR TO PROVIDE CUREDLAMINA INS COLOR I.Layout Of Work: 1.The Landscape Contractor shall stake out the Irrigation SCH 40 COMPRESSION TE CODESta.D MAP LOCATED SECURED INSIDE system as shown on the drawings. These areas shall be C.Coordinate the installation of all Irrigation materials, OR PVC SST TEE SEE RRI 1 - Tree Bubbler, Sta. 2 - Shrub Drip) 1 NON-PRESSURE LATERAL LINE PIPING. : including pipe,with the L.andac a Drawings to avoid interfering 0 0 O 2 � SEE IRRIGATION LEGEND FOR MAKE,MODEL, chocked by the Landscape Contractor and Ownor s Representative g P P n9 g 0 c 0 0 0 _ = a 0 OF STATIONS REQ'D. /6oneral Contractor before construction is started. Any with the planting of trees,shrubs or other plant material. // IEEE I I I I oo pO p O0 �I I I I O PRE55URE MAIN LINE PIPING changes,deletions shall be determined at this 0 0 CONDUIT - PYG check. METER 80 0 0 o I I I I-I(I I 3 CONTROL WIRES - TAPE AND BUNDLE O D.All Irrigation Imes,valves,and wiring shown on plan under 0 cc 00 IRRIGATiON SYSTEM SHUT-OFF GATE VALVE - =I I I paving are schematic only. Install these items In planting o O 0 0 19 0 00°0o FROM DOMESTIC WATER SOURCE • SEE EVERY 10 FEET. INSTALL ADJACENT O 90 Degree PVC Sweeps sae Contractor Is responsible for adherence to areas whenover possible,except when Imes must cross paving to 0 0 0 0 0 TO PRE55URE MAIN LINE. 24 VOLT OUTPUT 2.The Landscape P o P P IIII- 0 0 0 i the contract documents relative to equipment type,size connect planting areas or unless noted on plan. oo p o 00000 0 � PEA GRAVEL s ..�« O PROVIDE 2" DEPTH OF GLEAN BAGKFILL. O Installation,and location. However,the Landscape Contractor 0 0 0 0 0 (MIN. 2 CU.FT.) 4 i NOTES: O shall make minor adjustments,modifloations,and revisions 0 •• " ° to the Irrigation system,as required,to conform to elZe E. irrigation designer shall approve all design changes duo to site O SEE IRRIGATION SPECIFICATIONS FOR I. Common wire to be white and control wire to be q guarantee KFI AND COMPACTION black unless otherwise noted. 9 y I charges,or scaling errors In Irrigation Ian to a BAG LL VOLT UT I ions and to provide consistent 100%coverage OP Pan � ' g g P � 120 OL INPUT conditions p g 100% sprinkler coverage. irrigatior,Contractor shall assume full � / MINIMUM (1) PIPE SiZE 2 REQUIREMENTS. 3 2. No splices shall be made between controller and all Irrigation areas. rosponsibility for 100%coverage when infield changes are made � remote control valves unless otherwise noted. without approval from Irrigation designer. LARGER THAN METER +t BACKFLOW 3 S. Any deviation from the contract documents shall be verified O FINISH GRADE. 3 3. All exposed wire to be installed in conduit, unless UL °, FINISH GRADE approved UV resistent direct burial wire is used- with the Owner's Representative/6oneral Contractor prior F. irrigation designer shall not be responsible for improper •• •• • 4 s -Low voltage Only. to any irrigation system installation. The Landscape operation of system due to Landscape Contractor not installing MINIMUM BACKFILL DEPTHS FROM FIN15H a Contractor shall take full responsibility for adjustments to the Irrigation system per plan,poor workmanship,Incorrect GRADE TO TOP OF MAINLINE 11 4. Control wire to be minimum AtUG 14, one control any material or work that is not approved. pipe sizing than spectftod on plans or inadequate static pressure 6' wire a each controller, controller to be grounded as 24" FOR PIPE SIZES 3" AND LARGER ;���/����� /������ /��/` / / / / /�/� per manufacturers s ecificdtions. le)" FOR PIPE 51ZE5 2 1/2" AND SMALLER. !� / / / / / ij< p p I hall be the responsibility of the Landscape VC MALE ADAPTER (TYP.) provided b others all shall Prom water source. t s r p y p P E 5, 120 volt power to b. d / p p y 5.00 SUPERVISION And WORKMANSHIP: Contractor to notify the Irrigation designer of any site or equipment be according to local code. changes on approved irrigation plans prior to any installation The Landscape Contractor,personally or through an authorized and of the Irrigation system so as to provide design modifications. SCH. 40 PVC PIPING 6. Contractor will connect cotroller to power source and 4 competent representative,shall supervise the work constantly,and q supply labor, equipment 4 material needed for said com P P 3 3 connection. Owner to supply power. Contractor to ie keep the same Forman and workman S.Provide owner or his representative with all operating instructions, shall as far as possible P P P i tin P verify location of power source prior to subm t on the ob from commencement to completion. The workmanship of tools,keys,etc.as required for operation and maintenance EXISTING WATER METER field y p p g J id. Install per local code, of the Irrigation system. B the entire job must to every way be first class,and only ga y experience and competent workmen will be allowed on the job. CURB, WALK, ETC. H. Landscape Contractor shall also provide Owner with two(2)sets of "As Built Drawings" of the Installed irrigation system. 'OG D T I L TR' NG (NCB f�1_ CONTROLLER-NALL MOUNTFID 4.00 (SUARANTEE: I. Record accurotml on one set of re roduclbie prints of the �J y P N N.T.S. drawings,a record Ian drawin showing an changes. Kam It �✓ 9 P 9 9 y 9e P N.T.S. All material and workmaeh shalt be guaranteed and shall N.T.S. I A. p 9 up-to-date as the project is under conatructlon. In addition, perform to the completo ac+tlafact(on of Ownora Rmprmaontative/ dimension for true permanent points of reference the location of Cd 6oneral Contractor for a minimum of one year after completion and the pressure supply line,valve plug tees,and control wire. acceptance of the job. During this guarantee period,all required repair* and adjustments,Including adjustment to grade,shall be mado without additional expense for repairs to other work. 'I. O 00 SAGKFLOW PREVENTER: LEGEND 5. All damage to paving,planting,structures,and other A.Provide and install bockf low preventer unit Nnloss Speolfled LEGEND I. ELECTRIC EMITTER CONTROL VALVE ASSEMBLY. 1•� J improvements due to settlement of improperly compacted Otherwise)per State and Local Health Department codes and 2. BACKBONE LATERAL - PVC CLA55 200 PIPE. trench baokftil shall be promptly repaired to the satisfaction of current listings. Sackflow protection unit shall be located O RAlNBIRD 1402 BUBBLER. 3. FLUSH VALVE. SEE DETAIL G THIS SHEET Owner's Representative/6oneral Contractor at no additional expense. In such manner as to allow for screening by plant material. 1 T 1 Refer to plan for location. O PVC RISER - 5GH. 80 4. DRIP LATERAL - PVC GLASS 315 PIPE. G.This guarantee exclvdos theft,vandalism,natural disaster,or 5. BOUNDARY FOR DRIP VALVE ZONE. work on the system by others after final acceptance. The 6.00 TRENCHING: 8 ® PVC LATERAL PER PLAN. 6. SHRUB EMITTER DETAIL (TT'PIGAU. PIPE SIZING CHART I us, Candace t all Irrigation Landscape Contractor shall check,clean,and adjust J g A.Trenching shall be free of all rocks,debris,and sharp lateral lines and otherwise Insure adequate operation o4 the articles. Back filling shall be accomplished to a manner to O TREE PIT PER PLANTING DETAILS. 7. MAINLINE INE SET AT Eo6E OF sa:T AT EDGE o� 7 PiPE SiZE MAX. ALLOWABLE FLOW system throughout the guarantee period. insure no further settlement of ditch and to match adjacent RDOT BALL ROOT SALL b FINISH O GRADE 4 5 GPM\ O grades. No back Pilling shall be done until scheduled observation are made. 2 0 TREE OR PALM ROOT BALL •� `• 3/4' 10 (1 M 5.00 MATERIALS: 2 I •� •�` 8 t+ M TREE OR PALM TRUNK B.Gap or plug openings as pipeline is assembled to prevent entrance 7 6 ® / i i6 GPM � • 4 � A. All work and materials shall be in full accordance with the of dirt or obstruction by foreign objects. Remove caps or plugs when latest rules and regulations of the National Electric Codes,the necessary to continue assembly. THIS 15 ESPECIALLY CRITICAL 3„ O SET ON UNDISTURBED NATIVE $OIL ` i-i/¢, 26 GPM •O � Uniform Plumbing Codes,published by the Western Plumbing FOR DRIP LATERAL.LINES. Officials Association;and other applicable State or local laws _ �° {O MARLEX 90 DEG.STREET ELL. JOINT or regulations. Nothing in these Drawings or Specifications is a ' 1-l rz' 40 GPM � V to be construed to permit work not conforming to these codes. G. Install mainline pipes, lateral pipes,and wiring in commoni- P g trench wherever possible. Mainline pipe shall have a minimum '✓ _ 3 2 60 GPM of 24" cover(50" cover under roads and streets). Lateral pipes S. All equipment she l i be as listed in the legend,details,and shall have a minimum of 12" cover (16" cover under roads andrG E N E R A L IRRIGATION N 0 TE S _III_ A a ec[Ned herein. Install all equipment er details and streets). Provide a minimum of 4"of sand all around pipe f 5 3 -REFER TO PLANT LIST / EMITTER SCHEDULE P P s F apeatfications or manufacturer's recommendatlone. Any runs under streets,driveways,and vehicular access areas. _ FOR EMITTER MODEL AND GPH OR substitutions shall be approved by Owner's Representative/6oneral Provide a minimum 24"cover for all wiring. Tape and bundle THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE - __- - __ - g 2 E) G EACH PLANT SPECIES THIS SHEET. whin at 10 Intervals. T1e a loose 20 loop in all wirtn at an es D SHOWN ON THE IRRIGATION DRAWINGS AT THE METER OR POINT OF IRE4 I be 9 MAXIMUM FLOW DEMAND fled equipment shall 9 unspecified P Contractor in writing. An 9 _.._. U EMITTER LATERAL g y P of direction greater than 50". Untie all loop after all tonne tione -REFER TO EXAMPLE 13 LI-2. replaced at Landscape Contractor's expense. 9 P CONNECTION. THE IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO �"'� -�`• � SYSTEM - DETAIL SHEET LI-2. have been made. CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO • PERCOLATION TEST TO BE DONE FOR DEEP WATERING G.When the eclPlcatlona call for materials or construction of THE OWNER'S AUTHORIZED REPRESENTATIVE. IN THE EVENT PRESSURE DIFFERENCES ARE NOT 10 AND RESULTS RETURNED TO LANDSCAPE DESIGNER �.• / a better q IO ality or larger size than required by the above REPORTED PRIOR TO START OF CONSTRUCTION, THE IRRIGATION CONTRACTOR SHALL ASSUME 6 ` "■•.. ,�� �� mentioned rules and rogWatlons,the 5poclftcatlama shall FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. take precedence over the requirements of the sold rules and E 120 VOLT ELECTRICAL POWER OUTLET AT THE AUTOMATIC CONTROLLER LOCATION SHALL BE regulations. The Landscape Contractor shall furnish without PROVIDED BY OTHERS. IT SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO /� /� A Dfi�' i L�4YOUT any extra charge any additional material and labor when required MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL OULTLET TO THE AUTOMATIC CONTROLLER. TREE I RRI&AT I ON IDETAI ^" by the compliance with these rules and regulations,though the work be not mentioned in these particular Specifications or shown on the THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS IS N T S N.T.S. a Drawings FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS. AVOID ANY CONFLICTS BETWEEN THE SPRINKLER SYSTEM, PLANTING AND ARCHITECTURAL FEATURES. Approved By: THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO ALLOW FOR NO OVERSPRAY (IF ANY) ONTO WALKS, ROADWAYS AND/OR a /� BUILDINGS. THIS SHALL INCLUDE ADJUSTING EACH VALVE TO OBTAIN THE OPTIMUM OPERATING 5ASE INFORMATION PRESSURE FOR EACH VALVE STATION. B1': JHA ENGINEERING, INC. NORTH Date: DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS, GRADE DIFFERENCES OR DIFFERENCES IN THE AREA Scale: DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT I _ 11-0 AUTHORIZED REPRESENTATIVE. IN THE EVENT THIS NOTIFICATION IS NOT PERFORMED, THE IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn By: INSTALL ALL PIPE MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE TEFLON TAPE OR IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). TEFLON PIPE DOPE ON ALL PVC MALE PIPE THREADS ON ALL SPRINKLER SWING JOINT AND PO JH APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO Job No. Underground Service Alert ENCROACH INTO DISTRICT AND USER RIGHTS-OF-WAY. TREES, PLANTS WALLS AND IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO BE FAMILIARIZED WITH ALL PND USBNET STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR INS'1•ALLED IN CHMEN. AND USSR EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT 4010 e OR roG GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS PERMIT FROM C.V.W.D. 0 0� Ca; TOLL FREE WORK WITH THE GENERAL CONTRACTOR AND OTHER SUB-CONTRACTORS FOR THE LOCATION 1-800 AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING, BY IN ADDITION TO THE SLEEVES SHOWN ON THE DRAWINGS, THE IRRIGATION T�j-2 DATE WATER MANAGEMENT SPECIALIST 422-4133 i l CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF CONTROL WIRE SLEEVES OF DEVELOPMENT SERVICES SUPERVISOR TWO WORKING DAYS BEFORE YOU DIG SUFFICIENT SIZE UNDER ALL OTHER PAVED AREAS. / 87 0 TW 87.7 TW 88.5 TW I I I I 7 2 I .a a 86,2 TW 81.0 TRW 81iiiiiiinpow 0 - .7 TRW 82.5 TRW 32. 0.2 TRW 79.2 FG 79.6 FG 79.8 FG0 N 89.2 TW =Sam90.0 TW M� I I PLANT LEGEND so-IIJ II 81.2FG 85 I81.2FG - +75 75 75 - _ -S=0.50%- �- S=0.50%- �CTREES roR Q 1 T-7 81.2 I L�8 l ° 7 r S=0.50% . FL HPPROP. 5' HIGH WATER PLANT + c T tv N RAIN WALL 5YM. NAMEFF H I �?\ I Z Ll - - - - Acacia aneura 24" box Single-trunk 1 L 0.2a20 II I 5 / _ / Mulga z wallI I I I I \ � Q C1 Lu w � Gercidlum f. 'Desert Museum Sin le-trunk Q F.F.-80.40tn I 1 F.F.-82.50 24" box g 8 L 0.2 " )�i c c I o PAD-79.6 7 F.F.-80.50 ( / / o ' Palo Verde Q W v 4 PAD- PAD-BEi� F.F.-82.00 , : - I PAD-82.0 ;, 0 ® F.F.-79.70 0 0 I I I < PAD-81.5 I cs 7, 755 S. �� / O Pithecelloblum flexlcaule 24" box 51n le trunk 2 M 0,5 Q Q PAD-79.2 fl,81 0 S.F. 7 800 S.F. 7 800 S.F. I I - - ,��`L' U, g Q U i 0 , o n / ,, ';, •, cn I � � Texas Ebony W Q- -1[ � + 8, 16 7 S.F. I l t°, I I tr', I JI, ® I U - I N u_ D.Cs.I I 7. 7 r 4 I I / Cl- PALMS W w� 0 6 73 O LO N g b\ + WATER PLANT • + I I o 1 o I II I , - a a a a I I - I I v, - - - - - i 5YM. NAME SIZE COMMENTS QTY. USAGE FacroR p N m d ao ( I I 1 I 1 ILaw- I �' ° ® Washingtonla filifera see plan Leave fronds to 5 H 0.8 -- 'J California Fan Palm form skirt vt cn / / 23.44, ' G I I 1 - b - I I - I / / 1 ' s Hybrid Fan IPalmbrid see plan Skinned 6 H 0.8 C - i = I 1 1`� ,1��i F.F.-8�.50 I I I y t ra L sos Ili I I i l l i - 9 6 F. SHRUBS WATER PLANT \ \ N 1 N I N I N I I I �- SYM. NAME SIZE COMMENTS QTY, USAGE FACTOR �J � r 58.52' 75 5' l - N -� _ _ _ L _ _ _ 75 -�- 11 _ _ .._ o Baileys multiradlata I ai 63 L 02 _ !� LO BM Desert Marigold g U p d) Bou alnvillea 'Temple Fire' 17 M 0.5 0 ►� BTF BushBougalnvllleap 5 gal Low Growing 0 0 � I 2 78.01 TC \ I I �1 m FOSSIL FILTER MODEL 277.51 FL 9 5 gal Low Growing m Bou ainvilleo rosenka 5 M 0.5 NO. FB-24 PER SPECS. 0 1 Bougainvillea X v SHOWN ON EET 1 Q P E L E P L A C E 10.00' 5=4.2% - - -S= .50%--� - ' U < ma X Galliandra californica 5 gal. I L 0.2 d. to G S=4%- -..- . . - . . -S=0.65%- --� - ° O Baja Fairy Duster pp•O Gaesalpinea pulcherrima 5 gal. 13 M 0.5 •` O Q. Cr1 i 27783 TC o Barbados Pride 0 O _I N 277.33 FL / � (@ COMBO. CATCH BAS/N/ORYWELL / I ' Bushy h i 5enna phila 5 gal 6 L 0.2 ijOj to 0 n 68 L.F. OF PER C.P.D. STD, DWG. NO. 111A ( C� y ""may 8" ADS-N12 O + p = N® 4.5% Ghrysctinia mexicana gai. 23 L 0.2 C 75' 75 1 T I I co C. o I o o I o i , 1 75 Encelia farinosa 5 gal. 21 L 0.2 I I I I I I I rn I N \\ \ ' ®r=f Brittle Bush t� v 27 43 C.F. OF I I I to i I 1 O o - 8" ADS-N12 i i \ I n Lantana montevlden5i5 'Purple' i Sal Purple 3 M 0.5 ((� NV. © 71% - - ' I - - I ' - - ' , - - \� \ \ ° O Purple Trailing Lantana F.-80. 0 - _ 1 - �� \ \ AD-BD.O I ( I i Lantana montevidensi5 'New Gold' I go Gold II M O.5 I ? I I I \ \ I + New Gold Trailing Lantana + I I I o \ Leucophyllum frutescens Green Gloud 5 gal Ln 7.3' I LO A `" + 1 Iq L 0.2 o I \\s\\o \ \ + i Green Cloud Texas Ranger Ruellia peninsularis 5 gal. 8 L 0.2 Desert Ruellla 14 I I 1 \ Salvia greggii Sierra Linda 5 gal. 33 L 0.2 1 + I I I 7.6 7 (� I I �/ � \ \ \ I \�PGF h�a O Red Salvia 20 1 iI I 7, F.F,-79.70 `o I° 0 12 11 0 "� ols� 13 � I Ii I 1 o \ t<P PAD-79.2 o ° - a I `� DESERT ACCENTS + co F.F.-80.40 J1, F.F.-80.20 I cr, I - O o F.F.-80.10 o \ v ® iPAD- F.F.-79.80 to + cn PAD-79.6 PAD- o I I PAD-79.3 \ \ STORMTECH INFILTRATOR II I I \ WATER PLANT CHAMBER. INV.= 7,800 S.F. 7,800 S. 7,800 S.F. I �, I F.F.-79.50 I \ . e SYM. NAME SIZE COMMENTS QTY. USAGE FAcroR + (1 ROW, 70 MIN LENGTH 1 i I i 1 I i ( I 1 7, 991 S. I PAD-79.0 \ + 12 + I i 17,874 S. O Agave vilmoriniona 36" IP NO Scars 10 L 0.2 O + ( 1 I _ _ _ P POSED Rl G -0 WAY p g- - - - - - _ - - - Octopus ( ' f ' ` - -�}- - ' I f - - - PROP. 15" R.C.P. �� G + $ e Dasylirion longissimum 5 gal 5 L 0.2 °° PROP. 6 HIGH o - - - / 5 ��' l�l STORM ECH INFILTR DL NGN I "� � I DRAIN PIPE 1 '(•� - 1 N I I �- p 1 1 N I 79.0 D Cs. e etF CHAMB R. INV=27 S=0.50% v z FL HP 78.7 FL/HP o (1 RO 108 MIN L Dasylirion wheeler) 5 GAL. 11 L 0.2 BLOCK WALL - of -0.50% S-0.509• ! ° \ Desert 5 oon 1 84.6 TW , rn= 85.1 TO 85.1 TW 'r\ � . me - . . S= .50%- - - ...-- . . - . . 0 �. P - . . _ . . - .°. .,� . . - . . •° t'� p S8.5 121 79.2 FG ^ 79.1 FG 5 7 . `` - - - ' - 79.6 FG 5 p endens 8 ht. min 16-20 canes min. 6 L 0. 78.8 FIG -.r 84.10 TW 270 7 ! V ����}} 7 Q 2, + - ' . -S�0 50%- . . _ - 0° �---- v 6 FG 78.6 FG + . � + 1PE I ocotillo- - - s I n. 2 - - 9 � Hesperaloe parv(flora 5 GAL, 2q L 0.2 + O A e1F ° EF EF EF etr a 80 EF EF D.G. as 7 + O,f ® Red Yucca Er- O E EF EF ° E ° ern �® A OB Opuntla bigelovii Min. 24" ht 4-6 arms min. 11 L 0.2 + + ° o o ® O Teddy Bear Gholla O ® ® ® D O O D. A of3 OL 1 144 1 D G. 0 L 0 ® ® I e i�•1 I + A O O VINES © O ® D G. etr J ® ® age ® ° e G. e1r + DL O ® ° O O + ® ®ne / etF erF + ® ° O WATER PLANTO ® ® D G ® O O ® e 5YM. NAME 51ZE COMMENT5 QTY. USAGE FACTOR oo Bougainvillea 'Barbara Karst' 15 GAL. WIRE TO WALL 34 M 0.5 POWER POLE ^ Bougainvillea POWER POLE O � POWER POLE , POWER POLE EXISTING CURBJ GROUNDCOVER FRANK SINA -DRIVE _ _ a 5YM. NAME SIZE GOMMENT5 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - -Sj- - - - - - - - - - - - - - - - - - - - - -- - - - - � - - - - - - - D.G. Decomposed Granite 3/5" minus Siambilized, 2" layer after Brimstone` CAvdil®t5 W. Boulder Landscape Boulders see boulder Avail ® 5A. Boulder �J 'Crests' schedule ell - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - o o° e8 Rubble Rock 3"-8" Avail S.W. Boulder �° 'Crests' PLANTING NOTES 1. Before any plants are planted, all planted areas are to have been graded Ems. in an acceptable manner to asseure positive drainage per the grading notes. i p p g K' ' g - APPROVED - 2. Separate all shrub/ground cover areas from lawn areas with 2'x 2' redwood �• r� , -7 .,- headerboard or 3 layers of redwood benderboard with staggered joints FINAL LANDSCAPE P RAGE ` �°' � '` "-' (refer to planting plans). Stake headerboard with i"x 2"x 12" redwood �Sri.°,, r^r E`Lr: City of Palm Desert stakes spaced 48' on center maximum. 0A,r,�_ �q c c, fay O /� /� ll I I 3, Plant shrubs a minimum of 30 from all landscape light fixtures. GERALD FORD DRIVE L N05� P I NSP �T ON ��i-i 01�� Water Calculation Chart 4. Plant no tree closer than 3h" to an edge of paving or headerboard. 0�?D, rkIE�s IUD. 0A70 i 77':N F"'3 warm MNPM 5. Remove all stakes from vines, -Z -d C� Maximum Water Allowance 6, Refer to planting details. i,z-+e 21 1. Whenever possible, use plant materials acclimated to the Coachella valley. ..r U err, i: 4r C.F.' f.r;4F9 ",lT,.=•!d S. Lander-ape a contractor when t In vines is to use a drill to establish the I) Sleeving / Grading InmdZgne p y• g pilot hole to receive the red-head portion of the molly. a. Sleeve diameter, type depth and location Square FootageCakulations 9. When tying vines or espaliers, wires should be spaced as follows: lst (2) b. 5oil surface drainage, elevations and trash ( including weeds 8 rubble) at 1'-6" apart From finish grade, the next (3) at 1'-0" apart to make 1 Tree&Shrub Square foot 17225 p " J I- ; Turf Square foot 0. the top wire at 6 -0 above finish grade. Wires should be a minimum of L1J L1-I Total Square foot Cobble/Boulder 1013 8'-0' long center on plants. When vines or espaliers are closer than \ / I /� > Z 2) Hardscape / Boulders / Cobble Total LaatdscapeSuarefofootage " 10' apart, use a continuous wire between both plants. REFER TO THE �I Y IL ENS NEER1S 6RADIN6 I$ DRY NA6E PLAN --1 Total Landscape Square foot 18238 a. Sidewalk and wail layout PlamAnigaliort System Type: Zone Irr.Eft Area Seasonal Pgrafactor: 10. For protection of trees in turf areas leave a bare area approx. 4" away A.J Zone No. Eto Water Adj. Total Conversion Factors Total 4 0.75 651.957 6 Low Tree from tree base in all directions. For plant it size refer to s ecs, QA (� b. 00 Utilities l o c a t l o n Factor Sq.fL 0.62 748 MWA s_xnn Zonal Eto Plant Area Convey on Facto s Estimated p p {��/ IAI LAB it�� 1#E��t�V�� a 1 57.01 0-5 0 0.62 748 0 VaWe Fact. s4 R 6.62 748 Im.Eft. W.D.use FOR ALL E3 L O C I\ J N A La L= N O I I A T O N w c. Boulder type, size, weight and placement 2 66.82 0.5 0 0.62 748 0 11. WARNING Plant material listed ma or may not have been a roved b F- = Z sp:10 2.6s o.2 651.s571 0.62 748 o.7s z.sa y -L pp y 3a 75 0.5 0 0.62 748 0 summer 57.29 0.2 651.9571 °62 7as 0.75 8.26 the Agricultural Commissioner's office. -Landscape contractor, please Q 3b 88 0.5 0 0.62 748 0 Fat-Winer 15.97 02 651.9571 0.62 746 0.75 2.30 contact the developer for status of Agricultural Commissioner's approval Il Lj 3) Irrigation system - Rough-in 4 93.9 0.5 1P236 0.62 748 7os.7459 TOTAL t3'� or denial. Plant material not conforming with quarantine laws may be -1 LU 5 a. Trench depth and location Plartulrrigation System Type: Zone Irr.Eff. Area SeesonaFPlantFaeror destroyed and civil action taken. All plant material is subject to M Q 16.4 61 Pipe size and class Total Number of plants 373 Sprm/BubMdp 4 0.75 9060 7 LowJModTree inspection at the discretion of the Agricultural Gommissioner's office. / Number of )ants b water use %of Total Landscape Square Footage Season Zonal Eto Plain Area Convnabn Fect°rs Estimated '+'� c. Pressure test (125 si for (o hours) 1 Low 262 0.702 11387.517 Value Faaar s4R 0.62 748 Ira.ER. Water Use All plant material must be free from Red Scale CAonidiella aurantiU. U p 2 Low/Mod 0 0.000 0.000 sp:9 20.69 0.35 0 0.62 748 0.75 12. No shrubs are to be planted within 3ro" of hardscape, measured From center iRRIGATION NOTES:* FRANK. 51NATRA DRIVE a, 3 Mod 83 0.223 3s.000 Hummer 57.29 0.35 0 0.62 748 0.75 of shrub. ALL TREES AND PALMS TO BE BUBBLER IRRIGATED. •� , 4) Plant Material (trees 4 shrubs) 5High K 0 °-wo 0.000 Fat_y4mar 1s.97 o.3s o o.6z 7a8 o.7s °� � SITE � O ' 5 High 0 0.000 0.000 TOTAL 6LowTrees 15 0.040 ss1.s57 PALM TREE PLANTING NOTES ALL SHRUBS, GROUNDGOVER VINES TO BE IRRIGATED d. C On d I t I O n 7 Low/Mod Trees 0 0.000 0.000 b, Ty p e Plaranrrigattgn System Type: Zone Irr.Eif. Area Seasonal Plant factor: 8 Mod Trees 2 0.005 86.928 Spray/Brtbfpri0 4 0.7s a6az5 6 Mod Tree UJ(T H X E R I-BUG DRIP EMITTERS. 4p 9 ModA+Tree D 0.000 0.000 season Zonal Eto Plain Area Conversion Factors Esmrraterl tr C. PTacement-" 10 High Trees 11 0.029 478.102 Value Factor nit 0-62 748 a.EB Watause 1, Palms shall be planted using established planting procedures. Refer to * SEE IRRIGATION PLAN FOR DETAILED LA`i'OUT - Total 373 20.69 0-5 86.92761 0.82 748 0.75 0.99 Np�O palm tree planting detail 57.29 0.5 86.92761 0.62 748 0.75 2.75 15.97 0.5 86.92781 o.6z 748 0.75 0.77 2, I \\ 1 �✓) Groundcover (decomposed granite) Fal_Waae This line left blank intentionally TOTAL 4'S1 LIGHTING NOTES: Plant/rrigation System Type: Zone lrr.Eff. Area Seasonal Plant Factor: Planytntgation System Type; Zone irrEff. Area Seasonal Plait Factor: 3, Palm trees must be in a healthy condition at time of delivery. Palm TREE 4 PALM LIGHT FIXTURES SHALL BE ON SEPERATE b. Ospth alnd Spacing IBublorip a 0.9 11398 1 Low shrub fegbrorip a 0.75 6.006 9 Tree trees determined unhea%Hh or damaged at time of delivery or installation T 7 N� FF - I NO SCALE �.". Campy ctl0n Season Zonal Eto Plmd Area Corrveaion Factoa Estimated seaon Zonal EtO PW Area Conversion Factors F_s6mated CIRCUITS AND ON PHO OGFLL w O O OVER RIDE S!.lJ,TC1-I. Value Fad. sV.R 0.62 748 IrrL En. Wafer Use Value Fads sq.R 0.82 748 I'd.Etr. Winter use shaft be rejected by contractor an replaced by subcontractor at hie I spin 20.69 0.2 11387.52 om 748 .0.9 43.40 svrin0 20.69 0.65 0 6.62 748 0.75 expense. ` summer 57.29 04 0.2 t1397.52 0.62 748 0.9 120.17 NA-W, szzs o.6s o 0.62 748 o-7s 4, All palms shall be cleaned of excessive dead and ragged fronds or frond I /_) F nd I Far-winter 15.97 0.2 11387.52 0.62 748 0.9 33.50 TO winter 15.97 0.85 0 0.62 748 0.75 stubble. Gut fronds should be cut to a maximum length of 6". SASE I NFORMl�T I ON PROVIDED KR TOTAL. 197•06 TOTAL °-� g LIGHTING SETBACK NOTES I Q 5. Called out heights of palms shall be THE HEIGHT FROM TOP OF ROOT BALL- BY: JHA ENGINEERING ING. a. irrigation Plantfirrigation System Type: Zone Irr-Eff. Area Seasonal Plana Factor: PlanN ffigation System Type: Zone Irr.Elf. Area Seasonal Plant Factor. TO BOTTOM OF LIVE FRONDS. I) Valves, boxes and wiring SparylBg 4 0.9 0.000 2 Low/Mod Shrub SpraylBubfOrip a 0.75 476,102 10 High Tree ro• Palm trees to be properly watered in and soils properly tamped around the Locate light fixtures a min. of 4'-0` from edge of tree. i i) Controller operation and schedule Neaan Zonal Eto Ptem A" Conversion Foahms Eati noted season Zonal Eto Plain Area com«sion Fa Estimated P•I Value Factor .oft 0.62 748 Ini.EB. Water Use Value Facia .4 It 0.62 748 Im.Eft. WamrUae root balls when planting, leaving no air pockets of soil around root balls, Locate light fixutres 1'-0" from edge of palms. �. III) Sprinkler, bubbler and/or drip emitter type, flow spring 20.69 0.35 ° o.6z 74a 0.9 NPmO 2°.89 °.8 478.1019 0.62 748 0.75 a.7s �, Palm trees shall be planted vertically, unless noted otherwise. summer 57.29 0.35 0 os2 748 0.9 Summer 57.29 o.a 47a.,o,9 0.6z 748 o.7s 24.22 At all times a conscious effort will be made to lace P"'f rate and quantity per plant Far-Wade 15.97 0.35 0 0.62 7as 0.9 FarWinte 15.97 0.8 478.1019 0.62 748 0.75 s.7s S, Trunks should be rough with frond bases still securely attached, p TOTAL o.00 TOTAL 39.71 13. Trunks may not be totally skinned unless noted to do so. light fixtures in planter beds instead of lawn areas. IV) Overall operation Total Tree And Shrub 410.90 10, Trunk bases may be skinned to a maximum height of 3'-4' (taller trees /o') Q) 20' 40' 50, Approved By: il. Skinned areas above the ro' level will be accepted, at the direction of the These measurements are superseeded only when field v) A S-B u I i t ylarttllrrigaYnon System Type: Zone Irr.EfF. Area Seasonal Plant factor. Plantllrtigation System Type: Zorte Irr.Eft Area Seasomi Plana Factor. SprayZonal onl Eto 4 0-9 36 Fa 3 Mod y,Br, p 4- 0.$ ° „ Turf Landscape Designer. conditions warrant change by Landscape Designer. � � �� �� � Sea°^ ZonalEtO Plant ". ConveabnFactow Estimated seaon Zonal Eto Plant Area 00nvereionPacto. Estimated 12, Care should be exercised in the transport and planting of palms so as b. Tree staking Value Factor sq.It 0.62 748 Ira.Eft. water Use Value Fad. e4 R 0.62 748 Irn Eft. Water Use SP-9 20.69 0.5 3fi07.496 0.62 7as 0.9 34-37 s 0 20.69 0.76 0; 0.62 748 0.8 not t0 damage Or loosen bark. Date: G. O ver a I f Nymme 57.29 0.5 3607.496 0.62 7aa 0.9 95.17 1 11 =20' S..-er 15.97 0.5 360Z498 0.62 7as 0.9 28.53 summer 57.29 0.fi o 0.62 748 0.8 13, Severe cracking or holes in the basal trunk area will not be acceptable. Fa.V4aa 1ss7 0.76 0 °.62 748 0.a 14. One initial watering will be performed b subcontractor. Basin will be left -t 1 TOTAL 1s6.07 TOTAL °•0° - on each palm so subsequent watering canbe performed by others. Basin I�Ii/O� PlantArrigation System Type: Zone Irr.Eff. Area Seasonal Plant Factor- Total Turf 0.00 is to be removed during Finish grading. tit tI I Scale: SprayBub0ri a 0.9 0.000 4 Mo"igh 15. Subcontractor to untie frond tops (ro0) days after planting. QT'T 5�1 I. FIX UIRE C®J�� NT5 THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT („_�®, s PlanUlrtigation System Type: zone Irr.Eff. Area Seasonal Plant Factor. g,. IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 0.8, S_ ZovaWetO Factor tt o.6z C� 7�46Fa Irri.Eft. w�a0eruse WaterfeaturelEt 4 , ° 12 Moving R 16. Palm trees shall be planted a minimum of IS" away from building eaves. SPJ LIGHTING INC - SPJi(0-01 C 32 WATT PLT ACCENT LIGHT FOR PALM TREES 6 SECTION 65597 ET SEC). REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN DrawnB spin 20.89 0.65 0 o.e2 748 0.9 season Zonal want Area oonversonFaclos Estimated 11. Washingtonia hCbrids trunks are to have a minimum diameter of 24'' measured Y summer s7.2s o.ss o 0.62 748 o.s value Factor s4R °.62 748 ea.Ex. w use ` 120 VOLT, WITH LIGHT SHROUD VINES ON WALLS IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). PJf� Fat_yyrrter 15.97 0.r6 0 0.62 748 U. j spin9 zo.6s 1.2 0 0.62 748 t at 18" above finish.grade. W/ BLACK FINISH TOTAL o.00 Hammer 5729 1-z ° °.62 748 , MOUNT ON HADCO ROCKET PERMA-POST Far-vale tss7 tz o os2 7as 1 APPROVAL OF THIS DRAWING BY .C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO TOTAL 0•00 NOTE: SPJ LIGHTING ING - SPJ16-01 D 42 WATT PLT ENCROACH INTO DISTRICT AND USBR RIGHTS-OF-WAY. TREES, PLANTS, WALLS AND Job No. PlanWrtigation System Type: Zone Irr-Elf. Area Seasonal Plant Factor- Total Waterfeature 0.00 NO PALM TREE SHALL BE OUT OF THE ORIGINAL GROUND FOR MORE THAN 120 VOLT, WITH LIGHT SHROUD UP-LIGHT FOR CANOPY TREES PERMANENET STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR INSTALLED IN C.V.W.D. spry ra a os o.006 s High W/ BLACK FINISH AND USBR EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT Naga Zonal Eto Plant Area Estimated Total Estimated Water Use 410.90 (48) HOURS PRIOR TO RELOCATION AND PLANTING. MOUNT ON HADCO ROCKET PERMA-POST PERMIT FROM CN.W.D. 4010 f.i L-, 20.69 F 0.8 R 0 O.rr2 748 Ira. 0.9 Water tJse _ C�-� `�Pany a�„�` - summer 57.29 0.8 0 0.62 748 0.9 Sheet No. C Far-Wntr 57.29 ° 0h2 748 DATE BY cfl Iz TOTAL O.00 /� �` I I I /� /� WATER MANAGEMENT SPECIALIST T r N P E R T I1 T R N T L,4 N D S�s A P UJ,4 T C A L C,L h L,`mot T i ON fREFE�R TO 51-f T L f=- 2 O PLAN I I N� D T A i L=S a 1 ICE( 5 P C I F I C A T I ON 5 DEVELOPMENT SERVICES SUPERVISOR L � O� i NOTE, IF NEEDED STAKE SINGLE TREES 24"BOX AND Ifl 0 SMALLER, REMOVE NUR5ERY 5TAKE5. C O OO !' IN TURF AREAS LEAVE A BARE AREA r APPROX.4" AWAY FROM TREE BA5E IN ALL DIREGTION5UJI N z • DO NOT STAKE MULTI'S,UNLE55 NEEDED v o CINCH TIE5(2 EACH)DO NOT +�_ 1E v OVER TIGHTEN,ALLOW TREE TO Eo MOVE SOMEWHAT To BUILD CALIPER. NOTE: DEPRESSED WATERING BASIN Lu v PLANT SHRUBS MINIMUM OF 5' FROM TO REMAIN DURING PLANT s~ CURB IN MEDIANS, 2' FROM CURB/51DEWALK5 ESTABLISHMENT PERIOD. N IN PARKWAYS .. 2V2' � LODGE POLE PINE BAGKFILL MIX PER SPEGS. 0 TREE STAKE(2 EACH) -F- —SET 2"TO 4"ABOVE GRADE SET ABOVE GRADE 2" TO 4" a a a a a ""'4�- `'�-�,,,., � m DEPRESSED WATERING FINISH GRADE BA51N -- REMOVE FROM TURF AREA5 _ DURING FIN15H GRADING. —IIII I I=III II I I IIIII=I II III= NOTE; FINISH GRADE (IIIII= ROOT ZONE UNTANGLE MATTED ROOTS BY _=(IIIII (IIIII- LOOSENING ALL ROOTS @ ED6E IIIIIIIIIIIIIIIII (IIIII-(IIIII= BAGKFILL MIX PER 5PEG5. (IIIII= =(IIIII SEE sPEaFICATIONS. OF ROOT BALL W/ WATER FROM 11I111 — (IIIII- — — —111111= IIII=111111=III HOSE. DO NOT GRAGK ROOTBALL, NI- =111111 — — NATIVE UNDISTURBED 501E (IIIII—(IIIII—(IIIII=(IIIII_ �J P (IIIII NATIVE UNDISTURBED SOIL T C-� N w 00 FOR PLANT PIT SIZE REFER 3X R00T8AL L �J Q 00 TO SPEGIFIGATIONS. o U 3X ROOTBALL O L/1 N o O 0 TREE FLANT N(5 W/ DOUELE STA< I NO "a U A N.T.S. B n. rn 00 N. ( ` T.S. 6' a Q- cL N c N \ J co PLANT PALM 50 THAT _ AXIS 15 PLUMBCD OC 8'-12' VARIES 00 a VERIFY W/ LANDSCAFE DESIGNER M 12 GAUGE GALVANIZEI. ) WIRE TYFIGAL --1 FAINT W IRE TO MATCH WALL T � � ATTACH WIRE TO WALL W 1 TH i �l c0 GALVANIZED SCREWS (TYFIGAL) FAINT SCREWS AND W� IRE O TO MATCH WALL ~ T SCREWS TO 8E SFACED AT A 0 <C Q MAXIMUM OF &'-O" ON CENTER TRAIN FLANT ACROSS W IRE TO FULL HEIGHT AND WIDTH _ J TAMP d mTER-SETTLE I \PVILE PLANTING < r DO NOT PLANT LOKR THAN TOP K OF FI ROOT BALL OR TOP ROOT BALL 1L cSJ FINISHED GRADE NOT 70 BE LONET2 THAN FIN15M GRADE � O NO _ RADE `—I I�—III—III—f I i—Ii I I—I 11=1 11=1 I I—I j—ll 1=1 I I-1 I I I=1 I I� NOTE: ESFAL I ER TO 5E TRA I NED IN A FAN SHAPE UNDISTERBED NATIVE 501L TO PROVIDE FOR FULL WALL COVERAGE W ROOT BALL UNLESS NOTED OTHERWISE FALM TREE FLAN71 N� — — A L C ESFAL I ER TRA I N I NO DET N.T.S. D N.T.S. d a W p FINISH GRADE OL x W Lu cy z II 1— - ',III- IIIII m -_!'I-= = IIII=111111=III iI IIIII—�=I(IIII= ALL CAVITIES AND VOIDS SLOPED 6RAF=,)E .o ARE TO BE BURIED 404 OCOTILLO Q rCCS Lu O x FINISH GRADE m 2" TO 3' DEEP WELL N ROOT ZONE NATIVE 901E BACIGI=ILL 1 j _ _ SET ON UNDISTURBED NATIVE SOIL =I I III —IIIII= I=I —I IIII—III (I O_IIIII I M 4'T05'0IA.WELL LEVEL GRADE ALL CAVITIES AND VOIDS a NOTE: ARE TO BE BURIED � BOULDERS IN CLUSTERS ARE TO BE SET AT VARIED HEIGHTS 0r--,,0 11 LL0 FLANTI NO D I A t L TYFI SAL E30ULDER FLAr-..,EMENT W E N.T.S. T N.T.S. Wa� A w Approved By: SOUL D E R NOTE 5: I I OUAN. S I M5OL SIZE AFROX. Y NT. Date: — 50ulbers are to be CRST,� varying it 7-1-05 size. 5oulbers are identif ieb ®n lar6scaps plan 21 A 5lx4'x41 3 tons Scale: -• I^ THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT NONE by letter, ,4 beirg the largest an& IDS beirg the IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn By: ema ( lest. Larolsca pe contractor to vary the sizes 17 4'x4Ix31 1 =5/4 ton IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). FJH ar heights when placlrg boulders in clusters. APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO ENCROACH INTO DISTRICT AND USBR RIGHTS-OF-WAY. TREES, PLANTS, WALLS AND Job No. PERMANENET STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR INSTALLED IN C.V.W.D. 401 LUI C 5OuIOlers to be burieb rO less than 1/3 Of their 5 51X51X2I + 5/4 ton AND USBROM CIT .V.WpS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENTPER L eight upon f Ina I gradirg. Sheet No. 1 D 3Ix2Ix2' DATE / ton I�/ WATER MANAGEMENT SPECIALIST to O LP-2 �3 DEVELOPMENT SERVICES SUPERVISOR L OILSO sd. EMITTER SCHEDULE o 7' TREES /I HATER PLANT 5yM. NAME 51ZE EMITTER OTY. 1,15A61E FACTOR pis '7 Acacla aneura 24" box 1402 L LU MUIC30 0.2 7= F.F-80,40 -7 F., FF-82.50 Z) 0 Cercidium f. 'Desert Museum' 24" box 1402 8 L 0.2 PAD-79.6 PAD-79.9 PAD-80. PAD-82.0 Palo Verde LU a- FF-79.70 F.F.-82.00 00 PAD-81.5 7, 735 S. 0 PAD-79.2 7;P800 S.F. 800 S.E 7,8" S.I . ikexk_00 e 24" 'box 1402 2 M 0.5 > Texas 0 70 1 8, 16 7 S.F. QO W 17 I;z LU z PALMS M < < V OTY. HATER PLANT SYM. NAME 51ZE EMITTER USAGE FACTOR 6 1 77 I II 0 __7 / I� ® Hashingtonjo filifero see plan 1402 5 M 05 Gallfornio Fan Palm Nashin nio hybrid see plan 1402 (9 H to 0.8 $an Palm 1A C:3 F.F-8�.50 4 PAD- 00_1x� I I -� F. SHRUBS A HATER PLANT DRIP ZONE I 5YM. NAME SIZE EMITTER OTY. U5A6E FACTOR . , � I ► Q 3/ �, N L co Balleyo multircidiato 62 L 0.2 co 1901 XE3-20PC�-1032 U3 Desert Marigold 9 0) A O SA O 6) r1_ 3/4' E3u5 Bougainvillea tf, E :118 00 Ic 0 iNNN4 411 5LE VES Bougainvillea ro5enko 10 M 0.5 0 59al XE3-20PC,-1032 BA 4 Bougainvillea P E L F P L A C E _ - _ _ 4 Galliandra collf'ornica 5901. XB-20PG-1032 < E3aja Fairy Duster I L o.2 CL M C100 CP� (D Gae5olpineo pulcherrimo 59al. XE3-20P6-1032 15 M 0.5 jt 9 L 7- Barbados Pride Ga55la nemophila 5gol XE3-20PG-1032 11 L 0.2 9_1 O Bushy Senna (ro- 4) �44 F TF Chrysctinfa mexIcano I gal. XB-20PG-1052 23 L 0.2 L 0 Pamlanita (0 0) 0 Encelia forino5a 5gol. XE3-20PC,-1052 21 L 0.2 CID 0- EIrittle Bush ce) Lantana monteviden515 'Purple' I gal XE3-20Pr,-1032 (b M 0.5 Purple Trailing Lantana Lantana montevidengis 'NeA &oJd' 1 (301 XE3-20PO-1032 10 M 0.5 New Gold Trailing Lantana S.F. '00*i cop%llum frute5cen5 'Green Gloud' 59ol XB-20PC-1032 Texas Ranger 2 Green Cloud r5er e 6 L 0.2 Dh Ruellia penInsularI5 59al. Xf5-20PG-1032 18 L 0.2 (D Desert Ruellia 14O 5alvla greggli 5lerra Linda 5901, Xf3-20Pr,-l052 53 L 0.2 Red savla ® 1 � 13 ► , 1 11 --- I � L I PAD 2 F. 80.20 F.F.-80.10 1 80. 0 -AD-79.7 79.80 '000,/ DESERT ACCENTS PAD-79.6 PAD- .9 PAD-79.J 1110� HATER PLANT 7,800 S.F. 7,800 S. F.F.-79.50 PAD-7 . 5ym. NAME 51ZE EMITTER OTY. USAGE FACTOR 0 I II 1 1 1 1 z 361 (P M 7,8 74 S.F. Agave vIlmorinicino XE3 10 L 0.2 Octopus Agave Dasylirion IonqI55Imum 5 gal Xf3-20PG-1032 4 3 A 4 A 3 rp A L 0.2 ALM DRIf= 2 E D.G. &A DL NGN 3/41 DfRIF ZONE 3 Da5yllron v4heeleri 5 GAL. XE3-20PG-1032 1-7 L 0.2 Desert Spoon 10 ZONE. 2 �77 1-R\77,_f�= Fouquerio splenden5 6'ht. min. XE3-20PC-1032 6 L 0.2 r_A F V _-77_Eff EF F e9pera oe parv! Ora 0 "1 L 0.2 tn� 7 7_71 77--eM 743% 77_� A, erF UCCO 117-Al- (V)) 'Ad[,\ _If�) I I Opuntia blgelovii Min, 24" ht A3 20PG-1032 11 L 0.2 OE3 Teddy Bear Gholla 1.4' rz E VMS C. + low (D (D (R HATER PLANT 5yM. NAME 51ZE EMITTER OTY. AGE FACTOR 'Q1 Q) I 1A Bougainvillea 'Barbara Karst' 15 &AL. XE3-20PG-1032 24 M 0.5Qr POWER DRI:F= ZONE 2 kr� DR IF ZONE 3 f=CWE,-R f-OLE DRIP Z Bougainvillea PALM P.O.C.-VER. EXACT LOC. IN FIELD 2 `=0WER f-OL 5/4" METER- v# I" R-�- - - - .P. DEVICE PER CVAD FRANK SINA TRA DRI VE_ 75 _ _ _ _ _ _ _ _ _ _ _ _ _ _ Q) I --�- _S_ Underground Service Alert 0 R Call: TOLL FREE 1-800 422-4133 TWO WORKING DAYS BEFORE YOU DIG CY�E) � TfR CALC5 NOTE ALL IRRIC9ATION SHOV�N ON THIS FLAN 15 1.�) IA�5RAMMATIC, ONL"r. INSTALL ALL MAINLINE, LATERAL, VALVES ANL7� AN"r OTHER x ro x 18,230 x ro2 -148 8,E�1,70 CCF 6ERALD FORD DRIVE ASSOC, IATt=D IRRIGATION r-aUIFMENT KTHIN THE LANZ�S(��AFF AREA OF FROJE(��' T. LOW UJATEf;R USING f=L,4NT,5- - - - E.,4,,4,UJ.,4. e3.e x .2 x 14,0&(o x &2 148 e 243.2a CCF �10D LU4TE11R USING I=LANT,5- - - - E,A,A,UJ.,4. e3.e x .5 x 3,&,`�-4 x .62 e IE�e.73 CCF- RRICATION LEGEND U �41G Jl UJ,4TEfR USING f=L,4NT,5- - - - E,,4,,4,UJ.,4. e3.e x .7 x 4-1a x .&2 740 e 20.e4 CCF SYMBOL MANUFACTURER MODEL NO. DESCRIPTION NOZZLE RADIUS FLOW PSI PATTERN LU > GPM < TOT,4L E5TIr-14TED UJ,4TF=fR USA .431,S5 CCF RAINBIRD 1400 SERIES BUBBLER 1402 '0.5*6 FM 25 FULL All LU P ZONE RAINBIRD XB-SERIES XERI-BUG DRIP EMITTER XB-20PC-1032 2 GPH 30 LU )NI a: z O OL Uj LU > SYMBOL -1 PING, REFER TO DETAIL ON SHEET. _r < GENERAL IRRIGATION NOTES XI en FRANK SINATRA DRIVE THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE A RAINBIRD ESP-12 LX+ XIDESTAL MOUNTED, 12 STATION LIGHT COMMERCIAL CONTROLLER. MAXIMUM FLOW DEMAND SHOWN ON THE IRRIGATION DRAWINGS AT THE METER OR POINT OF 0-4 CONNECTION, THE IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO 14 SITE CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO PY11 RAINBIRD "DV" SERIES W/ ELECTRIC CONTROL VALVE FOR DRIP AREAS, SIZE AS NOTED ON PLAN THE OWNER'S AUTHORIZED REPRESENTATIVE. IN THE EVENT PRESSURE DIFFERENCES ARE NOT XCZ-075 REPORTED PRIOR TO START OF CONSTRUCTION, THE IRRIGATION CONTRACTOR SHALL ASSUME PIPE SIZING CHART FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY, RAINBIRD "DV" SERIES ELECTRIC CONTROL VALVE FOR TREE & PALM BUBBLERS, SIZE AS 57E Y A F 120 VOLT ELECTRICAL POWER OUTLET AT THE AUTOMATIC CONTROLLER LOCATION SHALL BE NOTED ON PLAN. PIPE SIZE MAX. ALLOWABLE FLOW PROVIDED BY OTHERS. IT SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO KBI #MIP-1000-T BALL VALVE (LINE SIZE), REFER TO DETAIL ON IRRIGATION DETAIL SHEET NO 5r_,,ALE MAKE THE RAIAL HOOK-UP FROM THE ELECTRICAL OULTLET TO THE AUTOMATIC CONTROLLER. 1/2 5 GPM THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS IS RAINBIRD MODEL # 5RC 1 " QUICK COUPLER VALVE- RUBBER COVER, 1 -PIECE RED BRASS CONSTRUCTION, 3/4" 10 GPM FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS. AVOID ANY CONFLICTS BETWEEN THE SPRINKLER SYSTEM, PLANTING AND ARCHITECTURAL FEATURES. USE ONLY RAINBIRD VALVE KEY- MODEL # 55K-1 w/ 1 " MALE TOP THREAD V, SASE INFORIII-IATION FROVIZ�E:1:;) Iro GPM THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PRESSURE MAINLINE PIPING USE SCHEDULE 40 - 1 " MAINLINE PERFORMANCE AND TO ALLOW FOR NO OVERSPRAY (IF ANY) ONTO WALKS, ROADWAYS AND/OR 5`*r": JHA ENOINEERIN�� IN�,- . CIO 1-1/4" 26 C%PM BUILDINGS, THIS SHALL INCLUDE ADJUSTING EACH VALVE TO OBTAIN THE OPTIMUM OPERATING PRESSURE FOR EACH VALVE STATION. NON-PRESSURE LATERAL LINE PIPING - PVC SCHEDULE 40 FOR PALM & TREE BUBBLERS & DRIP AREAS- ALL 3/4" LATERAL BACKBONE 1-1/2" 40 r-%PM 2- (00 GPM DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS, GRADE DIFFERENCES OR DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. SUCH IRRIGATION POINT OF CONNECTION - 3/4" COMMON AREA WATER METER SOURCE. 0 20' -40' ao, Approved By: OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S -REFER TO PLANT LIST / EMITTER SCHEDULE AUTHORIZED REPRESENTATIVE. IN THE EVENT THIS NOTIFICATION IS NOT PERFORMED, THE FOR EMITTER MODEL * AND GIPH FOR IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. BACKFLOW PREVENTION DEVICE-INSTALLED BY C.V,W.D. EACH PLANT SPECIES TH15 SHEET. GFRAPHIC: 5CALE INSTALL ALL PIPE MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE TEFLON TAPE OR NORTH Date; -REFER TO EXAMPLE BUBBLER EMITTER LATERAL TEFLON PIPE DOPE ON ALL PVC MALE PIPE THREADS ON ALL SPRINKLER SWING JOINT AND PIPE SLEEVING SHALL OCCUR UNDER ALL HARDSCAPE CROSSINGS. SLEEVING SHALL BE 4" DIAMETER PIPE. I` =201 SYSTEM DETAIL SHEET LI-2. -7/1/05 IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO BE FAMILIARIZED WITH ALL Scale: GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS INDICATES CONTROLLER & STATION NUMBER THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT WORK WITH THE GENERAL CONTRACTOR AND OTHER SUB-CONTRACTORS FOR THE LOCATION IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, `=20I AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING, SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn By: IN ADDITION TO THE INDICATES FLOW IN GALLONS PER MINUTE IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). PJH SLEEVES SHOWN ON THE DRAWINGS, THE IRRIGATION APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF CONTROL WIRE SLEEVES OF INDICATES ZONE TYPE ENCROACH INTO DISTRICT AND USBR RIGHTS-OF-WAY, TREES, PLANTS, WALLS AND Job No. SUFFICIENT SIZE UNDER ALL OTHER PAVED AREAS. PERMANENET STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR INSTALLED IN C.V.W.D. AND USBIR EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT INDICATES ELECTRIC CONTROL VALVE SIZE PERMIT FROM C.V.W.D. 4010 C-11, ;01�0 > Sheet No. U cc 3X DATE BY cl-i 4 WATER MANAGEMENT SPECIALIST LU 0,:0j F.F 8 PA 00 W7, 8 REFEF=, TO `5' 4EET L I - 2 FO F-., IfRfRI G;AT ION DETA I a r b 5FEC IF IC lit T I O N 6 DEVELOPMENT SERVICES SUPERVISOR 1.00 IRRIGATION SYSTEM SCOPE OF WORK The irrigation material shall include but shall not necessarily o1.00 IRRIGATION 5Y5TEM INSTALLATION PROCEDURES: O A. Work in this section includes providing all labor, material D g � r- equipment, tools, permits, and transportation necessary to be limited to the followings: A. Irrigation plan is diagrammatic. Irrigation laterals and mainlines Furnish and Install o complete irrigation system with 100% shown in horoscope is for clarity only. Install all irrigation coverage of designated areas shown on the drawings and I. PLASTIC, PIPE: equipment in planter bed areas. Landscape Contractor shall specified herein. a. Extended from 100% virgin polyvinyl chloride (PVC). verify actual location of power source and controller before Outside diameter of plastic pipe shall be the same size any irrigation Installation. B. The work shall Include but shall not be necessarily be limited as Iron pipe, with plain ends, All pipe and fittings to the following unless specified otherwise: shall be in accordance with the Society of Plastic B. Install all emitters and tree bubblers on uphill side of plant t dusr I. The Landscape Contractor shall visit the construction site, Industry Standards. material. Emitters shall be install one (2") above finish grade, take all measurements, and obtain any other Information any emitter left at on unacceptable height shall be reinstalled LEGEND necessary for a complete and conclusive bid. b. Pipe shall be continuously and permanently marked e with t cost to th a no e owner. I FINISH GRADELU . To sPRINIGLERs PLASTIC VALVE BOX LU - 5GH. SO 5LIP JOINT FEMALE ADAPTER BRAND LID 'RGV' - LETTERS 2" HIGH . . w the following informot ion:Monufocturer's name, normal pipe BOX COLOR: Green in Turf / Tan in Planters 0 I 2. Ordering, furnishing, and installing materials for complete C. Verify actual quantities and final location of plant material m including piping, valves, fittings, backflow rpl ee size; PVC, type, S.D.R. or pressure rating; and extrusion y q 2. PVC, PIPE (DEPTH PER DETAIL). system g p p g, g p date. with the owner's representative before any installation of the FIN15H&RAVE •~ Unless Specified Otherwise), dripper lateral lines, automatic Irrigation system. I°MIN.BELOW LID I" MIN. GRADE ( p pp 3. RAIN BIRD MODEL OGONTROL ZONE AS�MBLY. � d -75 controller, and final adjustment of lines to insure complete I" MIN.BELOW LID be handle with care and shall be D. Install Rainbird PGS screens as required to eliminate misting and � a � a a covers e. c. All plastic pipe, shall II g p p poverspray unto horoscope, streets, and structures. excavation materials and refilling especially protected from prolonged exposure to sunlight. I 12 I 4. WIRE CONNECTOR. 3. Trenching, stockpiling ex g trenches, including compaction of back fill and installation of sleeves. d. Protect all PVC, plastic pipe from damage during construction 10.00 IRRIGATION MAINLINE AND LATERAL LINES: 5. PILOT W R i ELEGTRIG VALVE I 4. Line voltage connections to the irrigation controllers and and storage. andLINE 51ZE 6. COMMON WIRE. A. Entire system shall be capped and pressurized to 100 low voltage control wiring from controllers to remote control P51 shall remain so for a two (2) hour period. Check all joints and - 3 - corrections for leaks. Repair and correct as necessary. FULL PORT BRASS BALL VALVE I r� � 7. 3/4" CRUSHED ROCK. valves. tonne p LINE SIZE (OPTIONAL) 10 2. PVC, FITTINGS: i fittings shall be ofpolyvinyl chloride(PVG), Type 8. (4) 2" x 4" x 12" REDWOOD FOR SUPPORT. 5. Replacement of unsatisfactory materials. a. plastic g TIRE SYSTEM SHALL BE FLUSHED PRIOR TO INSTALLATION _ p crewed B. THE EN qOd ELL-PVC, 5GHEDULE 40 q I I 2 - Schedule 40, N.S.F. and of IPS solvent weld or Contractor manufacturer as of pipe). Where OF SPRINKLER HEADS. Wherever necessary, Landscape ( I q. 12 x 18 RECTANGULAR VALVE BOX. 6. Gieonup, Inspection and approval. type, Losco, 5loone(some manu p p shall install anti-drain check valves (primarily on slope areas) to 6 threads are required, these shall be Injected molded and alleviate low head drainage/erosion. 6 SCHEDULE SG PVC, NIPPLE ®D IO. PVC, UNION FOR SERVICING ASSEMBLY. -� N 7. Operational tests. Schedule 80. All connections shall be solvent welded. o o - - - I L 0 0 0) C0 0 0 0 o 0 0 SCHEDULE SO PVC, NIPPLE r win s shop drawin s, warranties o o 0 o II. RECTANGULAR VALVE BOX W/ GREEN BOLT �J O 8. As Built record d a p g 6 -3/4 INCH GRAVEL SUMP g O O O O � DOWN COVER. HEAT BRAND VALVE STATION D h oil- , � g 11.00 IRRIGATION HEADS: (� and guarantees. b. Plastic to plasti joints shall be solvent-weld joints. o � SGH, 80 UNION o 2 GUBIG FEET C 00 O O O O O o NO. ON LID IN 2" HIGH GHARAGTERS. Pipe solvent shall be Johns-Monville "Blue" solvent weld A. Sprinkler heads along street curbs shall be setback 18" from 000 O O00 O O O O O O O E p g CONTROL WIRE MAIN SUPPLY LINE O O O O O O 12. GHRISTI"5 ID TA6 - NUMBERED TO �� N q. Verify underground utility locations. cement. all street curbing. Sprinkler heads along interior sidewalks CONNECT TO �1 hall be install 4" to 6" from an edge of walks, drive or path. CONTROLLER MAIN LINE FITTING MATCH DRAWINGS. 0 s y g 8 � 5 6 E X "C 2.00 GORES, PERMITS, FEES, LICENSE AND INSURANCE: c. Plastic to metal joints shall be with male adapters. the SCHEDULE SG TOE NIPPLE male adapter shall be hand tightened, plus one turn with a B. Irrigation heads on a riser w111 not be permitted along p flatwork. Refer to legend for height of all pop-up sprinklers. XERIC-7A710N F_LF_GTRIG GON7R0L VALVE (oo �, A. All work and materials shall be in full accordance with the strap wrench. Joint compound shall be Permatex Type IILGTRIG CONTROL VALVE latest rules and regulations of the National Electric Code, the (Only Schedule plastic may be threaded). D 0 b the Western Plumbing Officials C. Adjust entire system as necessary, Including locations of the N.T.S. o 0 Plumbing 0 Code, publishedy g licable State and local laws or sprinkler heads, radius of throw, and adding sprinkler heads if N.T.S. �- Association; and otheropp regulations. Nothing in these Drawings or Specifications is to 3. REMOTE CONTROL VALVES: if necessary for the Intended operation and 100% coverage �/ g g L)=C�END m � be construed to permit work not comforming to these codes. a, All valve locations are shown schematically on irrigation plan of all planted areas. and need to be verified with and approved by Owner's _ _ = c Re resentative/General Contractor. Irrigation valves will not i. ROUND VALVE BOX WITH GREEN BOLT- I. BROOKS #I100 10"xl0" ROUND D IN (� p DOWN COVER -(TAN IF IN SHRUB BED) BOX. HEAT BRAND TV" ON LID IN 2" B. The Landsca e Contractor shall promptly notify the Owner's be allowed in grass areas unless approved by Owner's 12.00 AUTOMATIC CONTROLLER: HEAT BRAND "BV" ON HIGH GHARAGTERS. TAN COLORED BOX LID.$ p Representative/General Contractor of any work outlined on Representative/General Contractor, VALVE BOX COVER IN 2" HIGH LETTERS. �- ~ the plans or specifications that 1s not in accordance with ! 2. FINISH GRADE. M p p A. The Landscape Contractor shall be responsible for the final \ / applicable laws, codes, and regulations. Without such �( . VALVE BOXES: electrical connection from the power source (BY OTHERS) to � 2. FINISH GRADE. 3. GHRISTY S I.D. TAG. (SEE NOTES). (� notice and appropriate modifications by the Ow 4 ner's controller as indicated on plan. Final controller location Representative, the Landsca e Contractor shall assume full a. Valve boxes shall be green Carson No. qlO in lawn areas shall be verified with and approved by Owner's Representative 2 3. FULL FLOW, BRA55 BODIED BALL VALVE- FULL PORT 4. 3/4" GRUSHED ROCK. 6" DEPTH. - p p and tan Carson No. qlO in shrub areas. Mark lid responsibility for any work executed which is contrary to /General Contractor. such laws, codes, and regulations. "Irrigation Control Valve". Install 2" above grade in PLAN I 4. SGH. 40 PVC, PIPE EXTENSION, DIA. TO ALLOW 5. FV PRODUCTS ALE 314"A BALL VALV groundcover areas wherever posER sible, B. Attach a typewritten legend inside each controller door, stating FOR MOVEMENT OF HANDLE ON VALVE G. License: the areas covered by each remote control valve. D _ - LENGTH AS REQUIRED. 2 6. PVC, SGH. 40 MALE ADAPT licensed I 5. 3/4" CRUSHED ROCK - 8" DEPTH. 5 � -l. SALGO A/R FLEXIBLE PVC, HOSE All work shall be performed by a C.-2-1 C al(fornia ' Landscape Irrigation Contractor. 5. VALVE CONTROL WIRE: MINIMUM 3 FOOT LENGT a. Valve control wire shall be installed per code. Wherever 15.00 COVERAGE TEST: 3 6. GOMMON BRIGK (2 REQUIRED). 8. SGH 40 - a0 DEGREE ELBO possible, place wire In common trench with mainline. Wire6.:. _ D. Permits and Inspections: pO° ° _The Landsca e Contractor shall obtain, coordinate, and pay for shall be UL-approved for direct burial in ground, size A. when the sprinkler system is completed, the Landscape o< 7. SGH. 80 NIPPLE TOE W/55 PVC, COUPLING q. RIGID PVC, PIPE. p #14-I (UNLESS SPECIFIED DIFFERENTLY ON IRRIGATION PLAN) Contractor, in the presence of the Landscape Designer 6 ° o ° pO _) any permits, fees, and agency Inspections as required and or Owner's Representative, shall perform a test which indicates o'° oo° ° ° pO °°�°'°4 8. 2" CLEARANCE. III=III-III approval upon completion of work. minimum with maximum voltage drop of 53b between valve7 I" IN LAWN AREAS. submit all certificates of appro p p the water coverage afforded the planting areas is complete, 7 °°o 080 opO° =I and controller. Common ground wire shall have white adequate, and does not sprinkle any structure walls, walks ° ° oS° q. PVC, MAIN LINE PIPE. 2" IN SHRUB AREAS. E. Insurance: insulating jacket; control wire shall have jacket of color or paved areas. The Landscape Contractor shall furnish all -° other than white. Splices shall be made with #2006-5 2" I IN TURF AREAS. The Landscape Contractor shall carry all Worker's Compensation, p materials and perform all work required to correct any e public liability and property damage insurance as required by Buchanan splice caps and 5M #35"16 5cotchlok seal packs. inadequacies disclosed. ° o o pO 2" IN SHRUB AREAS. o NOTE: USE TEI=LON TAPE ON ALL MAL • p y P p q °° ° °°° o°' cA )80 8 o V sae a .. -,- PIPE THREADS. Ci o °° 8 ail applicable codes, regulations, and the General Contractor. : e<�� o e°o°p °o °° °O 4 6. SLEEVING: 14.00 GLEAN UP: °° °° ° °O °° 8° $0 8°°08° 5 *FLUSH TO BE LOCATED AT THE END SECTION ° ° �° ° ° ° °° ° !�■� F. Site Verification! a. Landscape Contractor shall provide all irrigat(on OF ALL DRIP LATERALS. Prior to commencement of work, A. burin construction, the Landscape Contractor shall keep the Landscape Contractor shall sleeving (Unless Specified Otherwise) under all horoscope. g p shown on the plans necessary Coordinate all underground PVC, sleeves work with the verify all conditions and dimensions premises as clear as possible of material and debris.to achieve the intended design of the irrigation system. Any Owner's Representative/General Contractor. All sleeving �� I tt.-1_ VALVE L �us VALVE discrepancies shall be reported immediate) to Owner's re wired shall be Schedule 40 PVC, pipe and shall be a B. Upon completion of the work under this section, the Landscape p p y q p p Contractor shall remove from the premises all surplus material, N.T.S. N.T.S. Representative/General Contractor. minimum two sizes larger than lateral or mainline piping. tools, equipment, rubbish, and debris resulting from his work, and shall leave the installation site in a clean, neat condition. TT�� V1 G. Coordination: The Landscape Contractor Is responsible for coordinating this 6.00 IMPLEMENTATION: LEGEND ork with all other trades. This includes, but is not limited w to, provisions for racewaysw w 5 LEGEND I. BRA55 10 DEG. ELL (TYP.) and sleeving as well as water and 6 All irrigation work shall be coordinated with A. Prior to installation, Landscape Contractor shall verify static power sources. ga pressure, at project site. This system is designed to operate A'^ and approved by Owners Representative/General Contractor. p � - - O NON-PRE55URE LATERAL LINE PIPING. 2. BRASS NIPPLE-4" MIN. LENGTH. (TYP.) from 22 gpm at a maximum static pressure of 65 P51.Notify Owner's Representative/General Contractor at the site =III=III O PRE55URE MAIN LINE PIPING REDUCED PRESSURE 3. BRASS (YR STRAINER W/60 MESH y _ _ MONEL SCREEN. BAGKFLOW PREVENT H. Scheduling: immediately of any discrepancies and proceed as directed. _II IIII_IIII CONTROL WIRES - TAPE AND BUNDLE I 2 3 4. BRASS PLUG. The Landscape Contractor shall notify Owners Representative/ - O r t less than two (2) workin days in advance EVERY 10 FEET. INSTALL ADJACENT General Gontrocto no g y 5. BRA55 UNION. nested observation. - SEE NOTE TO PRESSURE MAIN LINE. of any requested B. If irrigation system is to operate from the golf course, verify IIII= - 6. FINISH GRADE. Q PROVIDE 2" DEPTH OF GLEAN BA ail site conditions: grading, static pressure, and point of 3 GKFILL. o 5 -7. BRASS NIPPLE. (TYP.) . connection for remote control valves. 4 O Layout Of Work: m 8. FROM POINT OF CONNEGTION ADAPT AS I. The Landscape Contractor shall stake out the irrigation O SEE IRRIGATION SPEGI COMPACTION FOR p of all Irrigation materials, D.G, D G BAGKFILL AND COMPACTION REQ'D. system as shown on the drawings. These areas shall be G. Coordinate the installation g 0Y 2 REQUIREMENTS. y Including pipe, with the Landscape Drawings to avoid interfering Q - - LEGEND � 6 q. 12" x 12" x 12" CONCRETE THRUST checked b the Landscape Contractor and Owner's Representative g P P P _ - _ _ _ = D 4 - y lantin of trees, shrubs or other )ant material. - - 3 - BLOCK. (TYP.). /General Contractor before construction is started. Any with the p g p I -I I FINISH GRADE. - I= I =I I= I. RAIN BIRD XB-##-1032 EMITTER % I -) I--IIII- I -I 10. BRASS GOUPL!NG. SET FLUSH W/ � y changes, deletions shall be determined at this - - - see emitter schedule For specific emitter 4 - - - CONCRETE (TYP.). V check. II= =I I = 2. BOWSMITH POLYFLEX RISER MINIMUM BAGKFILL DEPTHS FROM FINISH I I III -I II-III- III- II- III D. All irrigation lines, valves, and wiring shown on pion under (LENGTH AS RLYFL ED). GRADE TO TOP OF MAINLINE II. PVC, MALE ADAPTER. MAINLINE.- paving are schematic only. Install these items in planting I I I I= ro" 24" FOR PIPE SIZES 3" AND LARGER II =) I I = III i2. V INLI Contractor is responsible for adherence to areas whenever possible, except when lines must cross paving to 5. FIN15H GRADE. 18" FOR PIPE 51ZE5 2 I/2" AND SMALLER. - P G MA NE 2. The Landscapep size connect planting areas or unless noted On plan. I= � 12" MIN./24" MAX. the contract documents relative to equipment type, p 4. PVC, FITTING (5 x 5 x I/2" FIPT). installation, and location. However, the Landscape Contractor shall make minor adjustments, modifications, and revisions E. Irrigation designer shall approve all design changes due to site, 4 5. PVC, PIPE (DEPTH PER DETAIL G-ON THIS SHEET). 5 e to the Irrigation system, as required, to conform to size plan changes, or scaling errors in irrigation plan to guarantee 10 II 12 conditions and to provide consistent 100% coverage of 100% sprinkler coverage. Irrigation Contractor shall assume full g q all irrigation areas. responsibility for 100% coverage when infield changes are made without approval from irrigation designer. 5. An deviation from the contract documents shall be verified 7F,ENC,H I'N� 5ACXFLOJ N FfRE\/ENTO� I N5TALLEID 5'!r y 17fi'I P �M I TT�R �SS�MBLY D with the Owner's Representative/General Contractor prior F. Irrigatlon designer shall not be responsible for improper G to any irrigation system installation. The Landscape operation of system due to Landscape Contractor not installing N.T.S. N.T.S. Contractor shall take full responsibility for adjustments to0 N.T.S. p y j the irrigation system per plan, poor workmanship, incorrect an material or work that is not approved. pipe sizing than specified on plans or inadequate static pressure y LEGEND I LEGEND LEGEND from water source. It shall be the responsibility of the Landscape O Contractor to notify the irrigation designer of any site or equipment i. AUTOMATIC CONTROLLER (SEE LEGEND). I. ELEGTRIG EMITTER CONTROL VALVE A55EMBLY. �I 3.00 SUPERVISION And WORKMANSHIP: OI THIS ITEM INTENTIONALLY OMITTED C� UI changes on approved Irrigation plans prior to any Installation 2. BACKBONE LATERAL - PVC, GLA55 315 PIPE. The Landscape Contractor, personally or through an authorized and of the irrigation system so as to provide design modifications. O RAINBIRD 1404 BUBBLER. 2. 120-VOLT POWER SUPPLY WIRES IN CONDUIT. 3 FLUSH VALVE. SEE DETAIL 'G THIS SHEET p LAN competent representative, shall supervise the work constantly, and 3. PVC, CONDUIT-2 I/2 4. DRIP LATERAL - PVC, GLASS 3f5 PIPE OR PER P shall as For as possible keep the some Forman and workman G. Provide Owner or his representative with all operating instructions, 3� PVC, RISER - SGH. 80 tools, keys, etc. as required for operation and maintenance 5. BOUNDARY E" FOR DRIP VALVE ZONE- "DRIP ZONE on w t y q the job from commencement to completion. The workmanship of p 8 4O PVC, LATERAL PER PLAN. 4. FINISH GRADE the entire job must in every way be first closs, and only of the irrigation system. 6. DRIP EMITTER A55EMBLY DETAIL (TYPICAL). experience and competent workmen will be allowed on the job. O TREE PIT PER PLANTING DETAILS. 8 5. SWEEP ELL-2 I/2" 7. MAINLINE H. Landscape Contractor shall also provide Owner with two (2) sets SET AT EDGE OF SET AT EDGE OF 4 ROOT BALL ROOT BALL �6 FINISH GRADE PER PLANTING DETAIL 6. DIREGT BURIAL CONTROL WIRES ,�► a of "As Built Drawings" of the installed irrigation system. I TO CONTROL VALVES. i _ 2 O TREE OR PALM ROOT BALL q- I � ' i 4.00 GUARANTEE: I. Record accurately on one set of reproducible prints of the -7. 4" THICK GONGRETE FOOTING. drawings, a record plan drawing showing any changes. Keep it , 6 2 OS TREE OR PALM TRUNK ' / M A. All material and workmanshi shall be guaranteed and shall up-to-date as the project is under construction. In addition, 6 8. STAINLESS STEEL PEDESTAL (SEE LEGEND). �"' �► �,,, _ +► 40. �'" M to the complete satisfaction of Owner's Re resentative/ p for two ermanent oints of reference the location of s„ O MARLEX 90 DEG. STREET ELL. JOINT ( ` +-� performp p dimension p p - - _ o NOTE. INSTALL ALL WIRING PER LOCAL GODS. ' .� General Contractor for a minimum of one year after completion and the pressure supply line, valve plug tees, and control wire. - =III= I O00 O IIII=I i=IIII CO0+ C acceptance of the job. During this guarantee period, all required - - _ -000 repairs and adjustments Including adjustment to grade, shall be g III- I = IIII= III=I I I I a p adjustments, g J g made without additional expense for repairfj s to other work. III= -= III=IIII0 7.00 BACKFLOW PREVENTER: -III- 0 W B. All damage to paving, planting, structures, and other -I I- im rovements due to settlement of Improperly compacted A. Provide and install backflow preventer unit (Unless Specified 5 p _ _ trench backfill shall be promptly repaired to the satisfaction of Otherwise) per State and Local Health Department codes and -III 2 current listings. 8ackfiow protection unit shall be located Owner's Representative/General Contractor at no additional expense. 4 / in such manner as to allow for screening by plant material. .00 ~ / C. This guarantee excludes theft, vandalism, natural disaster, or Refer to plan for location. { PERCOLATION TEST TO BE DONE FOR DEEP WATERING work on the system by others after final acceptance. The q q AND RESULTS RETURNED TO LANDSCAPE DESIGNER 5 3 6 6 a Landscape Contractor shall check, clean, and adjust all irrigation lateral lines and otherwise insure adequate operation of the 8.00 TRENCHING: system throughout the guarantee period. GON7ROLLER GLOGK (PEDESTAL MOUNT) DRIP LAYOUT A. Trenching shall be free of all rocks, debris, and sharp 'T'REE/FALi-o I RRI COATI ON D Q 5.00 MATERIALS: articles. Back filling shall be accomplished in a manner to I / D insure no further settlement of ditch and to match adjacent �D N.T.S. N.T.S. N.T.S. A. All work and materials shall be in full accordance with the grades. No back filling shall be done until scheduled latest rules and regulations of the National Electric Codes, the observation are made. Uniform Plumbing Codes, published by the Western Plumbing Officials Association; and other applicable State or local laws B. Gap or plug openings as pipeline is assembled to prevent entrance Approve By: or regulations. Nothing in these Drawings or Spec IflcotIons is of dirt or obstruction by foreign objects. Remove caps or p"v93 when to be construed to permit work not conforming to these codes. necessary to continue assembly. THI5 15 ESPECIALLY CRITICAL FOR DRIP LATERAL LINES. ul ment shall be as listed In the legend, detalls, and ate: B. All equipment g specified herein. Install all equipment per details and �_I_O G. Install mainline pipes, lateral pipes, and wiring In common spec THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT NONE if or manufacturer's recommendations. Any trench wherever possible. Mainline pipe shall have a minimum Scale: substltutions shall be approved by Owner's Representative/General of 24" cover (50" cover under roads and streets). Lateral pipes Contractor in writing. Any unspecified equipment shall be shall have a minimum of 12" cover (15" cover under roads and IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION CHAPTER 3, ARTICLE 1 SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn By: replaced at Landscape Contractor's expense. streets). Provide a minimum of 4" of sand all around pipe for rivewa s and vehicular access areas. IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY PJH C. When the Specifications tail for materials or construction of runs under streets, d y Provide r minimum 24" cover for all wiring. Tape and bundle APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL T Job No. wk a better quality or larger size than required by the above ENCROACH INTO DISTRICT AND USBR RIGHTS-OF-WAY. TREES, PLANTS WALLS AND u.� II wiring at 10' intervals. Tle a loose 20" loop in all wiring at changes ANDPER USENET STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR INSAALLED IN CHMEN. 4010 W C7 mentioned rules and regulations, the 5 eciflcatlons sho AND USBR EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT � 9 P take precedence over the requirements of the said rules and of direction greater than 30 . Untle all loop after all connections PERi�IT FROM C.V.W.D. � regulations. The Landscape Contractor shall furnish without have bean made. Sheet No. LU r an additional material and labor when required DATE BY U any extra cha go y q T T WATER MANAGEMENT SPECIALIST LI-2 w =� by the compliance with these rules and regulations, though the work 1L ; be not mentioned In these particular Specifications or shown On the DEVELOPMENT SERVICES SUPERVISOR Drawings. a i 1 1 I PLANT LEGEND �, o a F- I Q TREES ❑ I � WATER �+�' � _ I 5YM. NAME 51ZE COMMENTS QTY. QN' QN• QTY. U5A6E FACTOR I I I I ' BM BM I Sweat Acadia 24" box Single Trunk I p O O L 0.2 K ,n I24" box Sln le Trunk O I 1 O L 0.2 E I I I �'� Acacia aneura 9 E o 2• p ❑ C� Gercidium f. 'Desert Museum' 24" box Single Trunk O 1 12 O O L 0.2 0Palo Verde G s - - - + + \ Oleo Europea 'Swan Hill' 24" box Multf-Trunk 1 O 1 1 M 0.5 :� 5 II I - - 3' Fruitless Olive 0 7+ 5chinus Molle 24" box 5ingle Trunk 0 I „�, _ Pepper Tree O 0 M 0.5 - - � " aaaa a I •� / 3 - tK + + �"` � • I I it to o I PALMS y q`� q`� WATER PLANT I .C . I ; • • / I - �' +12' , > � '/ \ 5YM. NAME SIZE GOMI�^fE�tTS QTY. QTY. QTY. QTY. U5A6E FACTOR 2 1 M 0.5 X � Q \ + \�\ \ � _. _ �,�, Ghamaerops humilis 24" box Multi-trunk I I � + \ Mediterranean Fan Palm + + / I \ eM _ +12 C Washin lento h bold see plan Skinned 2 2 2 2 H 0.8 -I-J \� I 117, BM - _ • Hybrid an Palm (� N cn -UM / - p I SHRUBS q ti - - - - - - - - - - - WATER PLANT C E - - - SYM• NAME 51ZE COMMENTS QTY. QTY. QTY. QTY. U5A6E FACTOR ^^ N (0 Baileys multiradiata 1901 3 4 5 3 L 0.2 E a eM Desert Marigold co C g ��I� Bougainvillea rosenka g 5 gal Low Growing 3 2 i 2 M 0.5 > C Bougainvillea Rosenka = o a ® d_ 3 3 L 0.2 i E O Gallicndra californica 5901. I 2 ,^^ Baja Fairy Duster /) - Gaesalpinea pulcherrlma 5 gal. O O I M 0.5 _ c Red Bird of Paradise 4M O T�/F N T� NORTH Cassia nemophfla 5 al I 2 3 I L 0.2 �,_ � M RTH ° g NO Green Cassia 1 _ Lantana montevidensis 'Purple' 1 9a1 Purple 1 1 4 1 M 0.5 - OPurple Trailing Lantana IOF T ® Nenw Gold Tra�ilintg Lantanaw <'o1d' I gal Gold 5 6 4 4 M 0.5 I El I Leucophyllum frutescens 'Green Cloud' S gal 5 3 3 5 L 0.2 Green Cloud Texas Ranger + Mulenbergta rigens 5901. 4 3 3 0 M 0.5 12 Deer Grass 08. • 3! I ® I Ruellla peninsularis 5901. 3 1 3 1 L 0.2 - - - - - - - O - Y / O Desert Rueiila JJ . . Ell 080 o I e lx • i - - / \ ". 7. DESERT ACCENTS .. fi q� + O I - - - - - - - + - - - WATER �T 5YM. NAME 51ZE COMMENTS QTY. QTY. QTY. QTY. USAGE FACTOR r l 12 ' • / Agave vilmorinlana Octopus Agave 361� `� NO Scars i eM I 5� Dasylirlon wheelers / II- - - 0 1 \ / Desert Spoon 5 GAL. I I i I L 0.2 40, \ I �� V.. 5 GAL. 2 3 1 2 L 0.2 X e� II I � � + Hesperaloe parvlflora -+12 BM „ X _ O Red Yucca / BM I I \ 'Y' ''� - \B\ +�o I I VINES - - - + G BM 1 WATER PLANT ❑ + BM a II / T QTY. QTY. QTY. QTY. USAGE FACTOR - - - I M �1� p SYM. NAME SIZE GOMMEN S ,' \ \ \ - - I Bougainvillea O I M 0.5 0 / \ �.. Bougainvillea 'Barbara Karst' IS GAL. WI1:E TO WALL I O X II +� - \ / North facing walls +0 Galliandra inoequilatera t5 GAL. WIRE TO WALL 0 1 I O M 0.5 i X / I � South, East 4 Pink Powder Puff West facing Walls o I GROUNDCOVER \ I 5YM. NAME 51ZE COMMENT5 i -�__�_ �O ''T#� _ D G Br m toneed Granite 3/8" minus G0 action layer after Avail @ 5.W. Boulder NORTH Landscape Boulders sccheu boulder Avail ® S.W. Boulder l PLAN FLAN TN�FE IrTNrFE Gresta Rubble Rock ~ o aeoo 3"-8" � Avail ® S.W. Boulder ^ , Gresta Iy1 r ' City of Palm Desert City of Palm Desert C IF(t�AT I ONS City of Palm Desert Water Calculation Chart ����� TO S���T ��_2 �O� ����� ������� ��� �� Water Calculation Chart ' I I * I ' Water Calculation Chart p IREPER TO SHEET L P-2 FOfR PLANT NOTE& 4 50UL�EIR SCHEDULE PLAN 2 TYPICAL FRONT`LARD LANDSCAPE i PLAN TYPICAL FRONT YARD LANDSCAPE - PLAN 3 TYPICAL FRONT YARD LANDSCAPE - C; LEGEND a` .4 Maximum Water AllowanceMaximum Water Allowance fRE�E R TO S�ra•4 E E T LP-2 �O R L A I `�Jam/5 C A F E +- (`� T(� j City of Palm Desert Maximum WaterAllowance ' Ir1pW Zone ImOUPZawe Water Calculation Chart Input Zone F Calculations Square Footage Calculations - Square � \/ PLAN 7 TYPICAL FRONT YARD LANDSCAPE Square Footage CiitDlation5 GERALD FORD DRI Y E Tree 8 Shrub Square foot 142g vs, --�` ' Tree E Shrub Square Mot t216 p -. -'� -'Alum Water Allowance Turt Square f°°` ° TreeBShM square root A. Total SquareooM Cobblel6oukdar 0 '-:' Turf Square foot 0 711ASrpsore toot s,.• Total Square foot CobbkofSoulder 0 Total Walerfedtue Square footage 0 ,... _ _ Total Wderleatune."s S Square footage 0 •feel + $`,r-+n. Total LandsOape Square Root 1278 //O i�ta,.r aterblow -,�' ..0 T1 Input Zone Total Landscape Square foot 7429 Told Wderfeatwe Squat 1 Zone No. Eto Water Adi Total Conversion Factors Total Total LalWscape Square foot 9906 - Square Footage Calculations Factor .ft. 0.62 748 MWA Zone No. Et° Water Total Corrvwsion Factors Total Zone No. Eto Wa6a Total Conversion Footers Total Faotor it 0.ffi 748 MWA Tre�BSF.rub Square foot 1455 1 57.01 0.5 0 0.62 748 D Factor R 0.62 748 MWA 1 66,82 0.5 0 0.62 748 D APPROVED - E-� •� 66.82 0.5 0 0.62 748 0 1 57.01 or 0 0.02 748 0 2 86.ffi 0.5 0 0.ffi 748 0 - APPROVED -le .•-4 Turf Square foot 0 3a 75 0.5 0 0.62 746 0 Total Square foot CobblelBoulder 0 2 86.ffi 0 5 0 0.ffi 748j 3a 75 0.5 0 0.62 746 0 Total Wakreefoot SquarfSoukl r D 3b 88 0.5 D D.62. .748 0 30 75 0.5 D 0.82 748 36 as D.5 D 062 746 D FiNAt.LANDSCAPE PACKAGE Total Landscape Square foot j Y455 4. 93.9 0.5 ,4 8 062 748 55.61064 3b 8g OS 0 0.62 7434 93.9 0.5 1216 0.ffi 748 47.321584 93:9 0.5 1906 OA2 748 Zorn No. Eto Water Adi Total Conversion Fa°IOf6 Total 36 ! Total Number of plerrfs 3, • .Q•"1 e V Favor ft 0.62 746 MWA Told t4unber of pglRs Square Footage ! 1 5T.01 0:5 0 6.62 748 0 Number of s b water use %o/7olal Landscape Tata1 Number of parts *0 Number W NaMs writ use %of Total Landxace Sauare Foresee 1 Low at OA72 674.806 Number of an4 order use %of Total L..d pe 9guaro Footage ;t Low 17 0-548 68G.839 z ee.ffi os o os2 T4a o 0.000 0.000 3a 75 0.5 0 0.62 748 0 2 LowMbd 0 1 Low 21 O.S25 1000.650 `2 LowMod 0 0.000 0.000 r Act ISM„N"^ e!r 36 88 0.5 0 0.62 748 0 : 3 Mod 14 0.389 555.722 2 H,pw,Mgd 0 0.000 Q000 ';3 Mod 9 0.290 353.032 LfUTLJWYG ITg4Ylt !J\/-• o 93-9 0.5 t455 0.62 748 56.62245 4 ModlHi O 0.000 0.000 3 Mod 13 0.325 6t9.450 4 Hgh 0 0-900 a000 5 High 0 0.000 0.000 ' 5 O 0.Ow 0.000 4 ModlHi 0 0.000 0.000 6 Low Trees 2 0-066 79.389 5 High 0 0.000 0.000 6 Low Trees 0 O.DDD 0.000 7 Low04od Trees 0 0.000 0.000 6 Low Trees i 0.025 47.650 7 LowA4od Trees 0 0-D00 0.000 .677 Total Number of plants ® 39.694 8 Mod Trees 3 0.000 10 000 Number of lams water,use %of Total Landscape Square Footage 8 Mod Trees 1 0.028 7 LowIMOA Trees 0 0.075 42.95 Low 77 0.472 68TO83 9 ModHTree 0 0.000 0.000 8 Mod Trees 3 0.075 T42.850 .9 ToolMdf Tree 0 0.000 0.000 10 Trees 0.056 79.389 j 9 ModltR Trce 0 0,000 0.000 40 109b Trees 2. 0.085 76.452 2 l.ow/Mod 0 0.000 0.000 itgh - Total 31 lu 3 Mod 14 0.389 SBS.B33 Told 36 10 High Trees 2 0.050 95.300 4 Mod 1 Hl 0 0.380 0.080 Total 40 15 High 0 0.000 0.000 6 Low Trees 1 0.028 40.417 eta Zoce ar.faJf. Area seasonal➢wa Factor: 7 LowJMod Trees v D.Doo 0.000 w.wer+aalwn syst Twee 0.056 80.833 pi•rrtlhrigatlon System Type, ZOM In.Elf. Area Seasonal Plata Factor: SpraYlaralrlOr'IP 4 0.75 0.000 9 ModO,igh Tree - PlardOmgation Systm Type: Zone In.Eff. Area 94rsond PIaR Factor: MamMdOdon SYdMI Type: Zone In Eff. Area Seasorrd Plant Favor: 8 Mod Trees 2 _ _....__. sw p 4 0.9 KT 1 Low Shrub Spr 4 0.T5. 0.000 9 Tree 0.000 0.000 - SprayBuDlDrip 4 0.8 6T5 1 Low StuW WaldOwipation System Tvpe: Zo1Y M..E9F. Are a."olni Fars Factor: T - Zone Eff. Area SearwW PNrR Feeler: 8 ModlT,Tree 0 seaaan Zonal Eto Plxa area senFamws Esun�ara s®n Zatal Eto ➢rr Me aonwran0Famrs Er°'ra4 X I;t0 High Frees 2 0.056 80.633 season law Eta Pkra area camersan Fxtors Esemaua SpraylBut4UriP 4 OA 1.01 1 LOW Shrub 4 •AO• 9 Tne Sworn ZomlERa Plant Rrw tana.laian Fevers Ermrat O � � 0 Total 36 Value Fxtor s.R OB2 14a M,ER. Water Use Value Facmr R. OBR TY Yn.EB. Weer Use Vasa Faaa A Offi 7w M-te. WaE,rtW Yrrr Fawr sq.R 0.62 740' M:0 Wew Ur 0 20.ffi 0.85 0 osz Tw 0.T5 �^^ �ME,• F•1e kw CawwrimiaM --Slated 8awm Zorwlfdo wet rw ': Pwara !s•rralei M s 02 666-8387 o.6z 7 0.9 2.04 20.89 0.65 0 0ffi Tee 0.75 � 11 sp.g. 20.69 0.2 874.8056 D.vt rY 0-9 _.57 yaw Fry a offi t« MFe, rwe4r Uw the• Fps a Me[ Mtwatar 1529 0.05 0 040 7w 0.75 t 0 57.2B 0.65 D oaz ]Y 0.75 20-tW 0.2 f000.fi5 sex 746 0.9 3.1 ?O.� 0: 0 0.76 suaarr 57.29 0.2 686.8387 O.sx 746 0.9 704 snorer 57.?9 0.2 674.8056 oBz TY 0.9 7.1_ 11►1/LT�/\1 V L- Fr-Wren 15.97 0.65 0 os2 TY 0.75 57.29 0.2 1000.85 vsx 7« 0.9 70.58 - y-row 1597 0.2 666.8387 osz Tw 0.9 1.96 -Yrarr 45.87 0.65 0 Offi 7w 0.75 0.00 •i1r� �/ _ FRANK SINATRA DRIVE �t I I Fr-yw4v 15.97 0.2 674.8056 osz TY 0.9 1.98 0.00 57.2• Q� O 0� 7N 0.75 TOTAL ,1.54 TOTAL - TOTAL tt.•e TOTAL 4barr ,597 0.2 1000.85 Offi 7w 0.9 2.94 ' PlamArrigatbn System Type• Zar M Eff. Aran 9esaorrd Pta1R Factor.__ PI dial S T Zone Irt.Eff. Area Seaswrd%iR Factor TOTAL t7,ffi 4W.ar 15.9T 0.� 0 Offi 7w 0.75 1' ..' 0.9 66T 1 Low Shrub p 4 0.75 OD00 9 hTree p ylpydg,l System Tore- Zone br.ETL Area seasonal➢Tar Factor. PtarMrnoaOon System Type- Zone br.PJf. Area sewrTd PkrdFpor. TOTAL OAO PWrt/krtgation System Type: Zone Irt.Elf. Area $easonal Ptaa FatlPr: Plwdfiri•aliOn Sgtem Type' Zone M Eff Area 9ax0m1Pgr Facx: O SpaYlBablOrtP ', 7 p ,rtay MY eaw.swtFeews Es•rlerr4 8py1„grp , 4 0.9 0.060 2 LowlMod Shrub SpravfeWTlDrsa 4 O.Z$ 79.769 t0 Tree pHw,ryH„ pp System Tore, Zone M.Hr. Area 9eoswd PWRFxor. Spwyl64r6Nrlp 4 0.8 OA60 2 LaMMod Shrub 4 O.Tb 7/d62 10 TreatCj Stearn Tavi 90 Plant Mw cmaram.Facewa Eswnle Serra Zonal Et PIamIMriOatbn Systrr,hoer Zane br EN Aro tWsorW PFaar Focht: seuan Zonal Eto Plot Arw cantata Ferns ErlaTtM 1 (/��.�J ti}�.�� N lke Var Fawr A 0.62 TY MEa. Warlr Vse IEtO Plate Mee Cmersron Fxtors ESMneled Seasm 2analEto PWr Mee COnerslr�FarWs EspnarW 4 eA •P•0 2 LowlMod Bhnb Senan ZOrlal�O ➢YIR arw farnarrim Faces EaYnari, V I TJ.rr. aF- vaw Factor sa.a osz TY M.EIf. Waur season Zone SDragatr6lOr,p s eJS 96.]W 40 Their yaw Pare R a62 Tw a4-Ee. warm. ]w 0.75 Vale Facer .tt. 062 Toe M.Fdr. Waa Use Swam mub E,o frt Not eawaaar Fawn 6YnrM Yahr Fawr a osz TY M9R weir lido .++s # f. r4•"`a u$,., fi8T.0833 O.ve 746 0.9 282 �l,e 20.69 0.6$ 0 a Vaw Faew .ft. 062 I46 M.ER. Wow tke V" 02 span Saran Zonal Be Fw4 Are CawararFadas Erllwrm s ''r' srrao 0.75 T4a 0.9 20.69 0-8 79.38889 a3x 740 0.75 1.45 - 20.69 0-35 0 Offi 746 0.9 sp:a 20.89 0.8 76-45161 a6t TY 0.75 1.44 t!{ i s" '- '"' `Z+l``e'a 8..�:�u j 887.0833 oaz TY 0.9 7.25 Srawr 57.29 0.65 0 0ffi TY 20.69 0.35 0 062 Vaau Fear .a a62 7w M.ell waarUw &area 57.29 0.8 78.451fi1 o.R 7« 0-75 3.97 S tl r 'O sr.nnrrr 57.29 0.2 sP'•�a smmer 57-?9 0.8 7S.38889 av Toe 0.75 4.02 20.69 0.35 0 gffi 746 0.9 `�• Pro a offi Tw MFe, wrr uw Swore 57.29 0.35 0 a.ffi 7w 0.9 [1 ! y4Maw 1597 0.2 88T.0833 0ffi 7w 0.9 2.02 Fr-wart 15.97 0.65 0 0ffi rw 0.75 Me, 5729 0.35 0 osz ]4a 0.9 20.E 0.8 95-3 IMME 746 0.75 ,.74 y.trr 15.97 0.35 O offi Tw 0.9 y-ear 15.97 0.8 78.4518, oaz 7w 0.75 1.71 I n t-""'?'�;fr""t* r=-`,�. •/._ TOTAL 11.89 TOTAL 0.00 yr v4roe< T5.97 0.35 0 Osz TY 0.8 Fr-wtrr 15.97 D.8 79.38888 aez Toe 0.75 1.12 SL29 0.35 0 0ffi Toe 0.9 I 0.90 TOTAL 8.59 -ype,r 15.97 U.35 0 obx 70 0.9 a'w"'r 57-29 0-8 95.3 sex Tw 0.75 /.83 1 TOTAL 0.00 TOTAL e•ffi -- Zone In.Elf. Area aeasollal plan Eerier, ahon T Zone In.CM. Area 84azorW Plat Faemr. TOTAL 0.00 y'Nir 15.87 0.8 95-3 0. 7a 0.75 1.35 Total Trte And Stoup 46.02 TOTAL TOTAL 7.92 Total Tee And Shrub 39.44 r` f r P` _ Plaworloation System Type: PlaNkrle System voe: - Sparv/eublDrip 4 - OA Oe00 2 LpwlMod Shrub 1 0.T5 a0.633 10 h Tree Swat Zonal Eto Plat ww CmvrrA Fawrs lMod 5eaar Zonal Eto Plant arw conwrrlm Fawrs EsRnur4 Plamacrlaatlan System Type• Zone Irr.Eff: Are swsonal Ptah Fxror. Told Tree And Shrub 80.44 PI eta T Zone Irt.Eff. Nee Seasorld Plata Factor: Pleamrti abor,System Type: Zone Irt.Elf. Area Seasonal toss Factor. f;:. PIxalMladfon System Type' Zone ur.Ett. Aria Seasonal Plant Fertor: - 6eawn Zonal Eo Plant erw ConwrwrF_ EnYrolra S0`aylgpb�"p yaw Fagx .a osz TY M.Ea. wear use yaw Fro .a Offi Tw M.Ea. waaruse a 9.9 ss5.72z 3 Mod Sp7avlguplprpi 4 8.8 o tt Tort S T In.Efl. Ana 8eawrwiPbaeFarmr. / 0.9 JS7e72 3 Mod 1 0.6 0 41 Turf `''*�e7'•••-'"..-�.d.>s; I T 20.89 0.35 0 atz Toe 0.9 20.69 0.6 80.83333 0ffi 7Y 0.75 7.48 SPraNBetbIDrM Zr4 OA 6/9A60 3 Mod PlagDbrigedorr Svd"rr Type: Zone M.ER. Ana SeaswW Ptaral Fasror: seasa� Zonal Et. PIaM Mee comersln Fangs Esamatea Season Zonal E,o sap Mee CmrerssnFxbrs Esemaea searon Zonal Eto Pore s4« rmrrron Faces ESIYnaer Smaw 20867o9 6.35 0 0.62 746 0.9 57.29 0-8 60.83333 Q62 ]w 0.75 4.09 Vale Faax .R. 082 ]de M.ER. Water Use Vaha Fxbf s.R. a.62 T4a Tin.ER. Water Use Seeaa ZmwR Eio P0M Nor Carvalrb.FaM EaaIIM SPn1dBUWO1iP 4 - 1L8 0 11 7grt Vote Farw syR Ob2 TY M.9r. WawUsa Var fear sa.R OeT 746 M.rdr. Wow Use 'JII'rL,' y�7l�n/ I affi TY 0.75 t.14 zz p-g 5.?9 20.6s 0.78 0 osz Toe 0.8 vat Fps ar.R osz TY mFa. Wrarer. sYaar Zonal Eto Piano arw cmwmanFaWs E4lwr4 spec 20.69 0.5 353.0323 osz Tw 0.9 3.38 20.ffi 0.76 0 nez 1w 0.8 J_.C?.=-�,--%L._-_ y-wart 15.97 0.35 0 oBz ]Y 0.8 y.Wyr 15.97 0.8 80.1i3333 20.69 0.5 555.7_2 OBx TY Spmg t TOTAL 0.00 TOTAL 8.71 spas ?11;69 0.5 618. o.6z T,6 0.9 5.8D vow rvaar .e osx. 7« as Ea. woes ire 57.29 0-5 353.0323 as T4a 0.9 9.31 y,,,,,r 57.29 0.6 0 pffi tY 0.8 �►��_�g� 5729 OS 555.7222 sax T4B 0.9 14.66 s�e,,,,,e; 57.29 D.6 0 osz ]Y 0.8 5T29 0.76 0 atz 7« D8 Fr-war 15.97 0.5 353.0323 osz TY 0-9 2.60 Total Tree And Shrub 48.12 Fa-wart 15.97 0.5 555.7222. OS2 Toe 0.8 4.09 jFan_mm 9597 0.76 0 8.62 rod 0.8 Storer 57.29 0.5 619.45 0ffi 7Y 0.9 18.34 _ y-wMr 15.97 0.76 `V' 2A.04 0.00 -1Wer ,-87 0.5 619.45 gffi Tot 0.9 4.58 57.29 0.8 0 osz rw �.9 TOTAL 15.ZT TOTAL U.00 1 . J ,ti:;9 1 `O TOTAL y-war 15.97 0.76 0 a62 746 0.8 _ _. ., Pr.�rriaatbn System Type' Zorre In.Eff. Nea SeasOpal Ward Factor. TOTAL 28.80 SC/ALE PtamA atiorr S T Zone Irt.Eff. Nea Seasonal Plat Factor: TOTAL Told Turt 0.00 "` ' T Y.'.. Total Turf 0.00 TOTAL 0.00 PlamArrigallon SysMn Type: Zone Irr.Eff. Area 8aasonal Plant Factor: •`PP•: 1 SpaYlaublDnP 4 0.9 SBfi.A13 3 Mod 3 4 0.e 6 11 Turf .-.____.. plarltlartga0on 3Ysteln Type' Zorn br.Elf. Afla Seasonal Plata Factor. Sp7apaublDdp 4 OA. 0.000 [ h ' PlrrUh71sW0on SiR.M11t Typs: Zone In.E/f. Area 8aearlal Ptsr Fardor: Tafal Turf 0.00 Plant4ffkmUon Sytetrl Typo' Zane Irt Eff. Area Sea."Foe Factor. Inset Zonal Eo Fro au. GawrxbnFaars Erl1eW Seasm Zonal Eto Pwa tow Crwram Fasts Estanaled Spr rlblDrlP 4 0.9 ooW 4 ModX h PIdlWnaaOon System Twe: Zone M.FXf. Area saasona Plano Fator: year Far r4R Offi TY M.�- wowlke Yie Frw R 0.82 ]Y M.ER. War Use 9pr•pBIdMDdD 4 0.9 0.8q 1 h Seasm Za1lal Eta Plot tow crnwrsw.FawO Errwpd Watertarture 4 7 0 12 too» spo 2aoe, 0.5 565,8333 °.¢ T4a 0.9 5.39 20.89 0.76 0 osz Tw 0.8 season :oral Eo Ra4 area Comersian F_ Esomaan Wall, 12 Moving 5eaam Zortd Eo Fort arw Cmrwam Fact4n rM PlanNnlOdiOn System Type Zone MErr Am aa...ed Plate Failor yaw Fats r4a osz Tw M.Fa, wwrua. Vale Fxror s.R. a82 74e M.ER. Water Use Seasm Zonal Eto Rua Area Cornarsim Facmrs Esamaetl Valve Faacr R Offi TY M.eR Wew lw Wafetfedwe 4 1 0 12 MOW 20.69 0.65 0 Offi TY 0-9 Searm 2ona1 Et0 ➢all[ Arw CorrnrvortFats Eawwrtl vJ s,a-r 57.29 0.5 565.8333 osz TY 0.9 14.93 20,2g 07] 0 rt x T4a 0.6 2Q68 0.85 0 osz ]4e 0.9 Yea Pawl R a� T« M.ER. Waaus. E3A5� I NfORMAT I ON 'ROB I DAD Qex Tw 0-9 4.93 0 Offi 7« 3.8 Vale Fawn s.ft. OB2 T48 Im.Err water Use 2D,69 0.&5 0 Offi 746 0.9 Scum Zonal Eto Plan Nw emr«s+al Farhat Fatimra4 S"'^1ON $7.29 D.65 0 0.ffi 748 0.9 j Fr-VAarl 15.97 0.5 585.8333 y.yrr, 15.97 0-76 2069 1.2 0 gffi 746 1 TOTAL d4.48 p_Op s;rar,er 5729 0.65 0 O.sz ]4e 0.9 20.69 12 0 oaz r48 4 Srmor 57.29 0.85 0 gal 7Y 0.9 Vaw rant .R affi TY art En. wave Dar Fao-,Wrr 15-97 0.65 O osz 746 0.9 Swry 5729 ,.2 D a.6x TY , �Y. JHA ENG I NFEER I NG, INC. TOTAL Fa,-wnpr 16.97 0.65 0 osz Toe 0.9 TOTAL 0.00 Told Turf 0.00 0.00 sum„er 572a 7.2 0 osz Toe 1 y.vWr 15.87 0.85 0 0ffi T4a 0.9 spas 20.89 1.2 0 0.ffi 7« 1 Fr-ww 15.97 t.2 0 Offi Tw 1 Plam/hr aliens T Zane In.Ett. Area SeasaW PWRFacter. TOTAL ;Fay-wrier 75.97 t.2 0 oaz ]4e 1 O.W TOTAL 0.00 stator 57.29 1.2 0 Offi 7w , TOTAL 0•PO Spation velen 4 0.9 OeaO 4 -h Area Seasonal Plan Factor. TOTAL y-vWr 15.97 1.2 0 OM 746 i Total Waterfedure 0.00 warm Zonal Eta Pont a4 Corn 0.011 Ferns t2it PlmtNrtaation System Type' Zone In.Eff. _ Total Waterfeature 0.00 ;� 'r TOTAL 0.00 Piartlirripat(on SyeWn Typo Zone Irt.Ett. Nea Seasonal Plot Favor: Water(eatl,re 4 1 0 12 MOWn pl -a0on stemT Zone In.EYf. Area seasons Plant Factor. SpraylBublDrip 4 0.8 0.000 $ "h .� yaw Factor sot.a eve T4a M.ER waW Use PI S T Zorn PJL` Sueerrl Ptaa Favor: ! s- 20.89 0.65 0 oBz Toe 0.9 Serra Zonal Eta Part Mw cana,imrawls ersnar4 SpraylSubfDrip 4 0.9 0.00o s High SpraylauWDriD f OA s h Total Wdertedure o.Do sera. Zonal Eto Port tow ErmaW Total Estimated Water Use 39.44 a srr4a 20.29 065 0 sex Toe 0-9 vas. Fawn ryR osz 7Y M.Ea. wow lose seasm Zonal Eto Plan sea Essmatea Total Estimated Water Use 46.02 54asae Zonal Et. For. err ErlrretM spars 20.69 Fawn 8 sr.A 0 °.ez 7Y M 0.9 y-w.r 57.29 0.65 0 6sx TY 0.9 sp ro 20.69 1.2 D offi TY t vale Faaa saR 0.81 74e Ira.Eff. ware.use vat Fro r¢R oe2 TY hti Ea. WawUu TOtdl Estimated Water USB 60.44 TOTAL 0.00 Sureaa 57.29 1.2 0 °.¢ TY 1 sUrag 20.69 0.8 0 osz Toe 0.9 20.60 0.6 0 affi 74e 0.9 sugar 57.29 0.8 O offi 748 0.9 Fr-1Wr 15.97 1.2 0 0ffi 7Y , 0.00 sawner 57.29 0.6 0 osz ]4e 0.9 surer 5728 06 0 oaz 7w 0.9 TOTAL 15.97 0.8 0 osz T4a 0.9 TOTAL Fr-YJ r 15.97 0.8 0 OB2 ]4e 0.9 y4W4r ,5.97 0.8 0 osz 7w 0.9 AL 32 1 Approved By: Plam/Irrilldion System Type' Zone Irt Eft Area Seasonal Plant Factor. Total Waterfeature 0,00 TOTAL 0.00 TOTAL O•00 (Q PlanMrdoafion System Type: Zone In.Eff. Area Seasonal Pisa Factor. SDray1BPU/DdD 4 OA 0.000 5 h s-ar Zo1rNEto 7+.re ore, estate TOWEstimatodrPlat> us% _48,12 :1 . ..r� Yew raw .a oa 7r M.DR wave,ur Na4rOkr10M1On NNem Tw.' Zaw Mf Id11 Are• sewonr➢YrnF•[tar: SpraylauNDdn 1 9.7$ a.600 B Low Tree gex T« • 1 0.75 IS 3110 6 Low Tne 4 0. Law maven ZA�o.�.EK Fart. ao4 E v 1y ly are ne 5.Zo 0.• 0 am 1w 0.9 s...m OUD Eta Plan wee F Frbmrra •earn EI• rrr arw u•..ro vow ram. a offi r 7Y M.m. veer uaa 1 I SCALE ' oex 1w ���M///IIII e 1 NORTH rr 44aea offi 1r Vaor row n oaz p Men wa.,ure Vew r.r a as 7« all W TOTAL 0.00 _.8 9. • 0e7 14e oa 749 elwar .07 0.2 0 OR /w 0:7$ Q /J► 02 79.1ee•9 oe1 74e 0.76 1.0, lew� 0 1.06 64x 7« 0. f Ir 4wr 15. 0.2 0 sax rr_wort 16.97 0.2 78.70•a9 oe7 lu 0.76 0.2• a4Mrr .• 0.2 I. 0•i 7« 0.1 TOT Om ^� lC PI Traw: oneon, / TOTAL 1A KC-ale: 4 •. w.417 • Lew Tm aeeaw He rrr arw / Talent rrafr�_-.__y._._-Type: ZOM kr elf Ar4a •.ee.nr Plant FaPor_- 1 0. O.ON 7 L.ory/Mod Tow v w r.ra a O.ax 7w M.u. wow the • 4 0.75 o.00D 7 Low I Mod Tne Wil 8,� I aa.rm land eto For. tow eaarrer 0571 OQ /Y hum :Oral Elo Plwr Ma F Frpnaen •worn Zonal ter 4rY 4anelee V 20,89 8 /sew R a,= 1w M.0 Wow Tare Trot. .zo 02 ,o.,6e7 asx T« oa , yea row R 6.] 7,R Men Wr4,Uen a oa 1« wr. °p '" THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT /a ll_ -Oil rr 4wr ,.9 0. 40.41057 on T« o. o.0 3 _oe Dee ,Y 7« err.. :zo oa a 1« o: IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, I 0. Na- 67.19 0.76 0 0 7Y 0.76 _ 7« - y4wr 1 •7 036 0ffi 7« 0.75 rr nwen 20.60 -0ay o 05 I.. 0.76 r«4yFw oa 7w oT o.00 SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn By: o.•o oT o6wea: aawl, IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). P IH 7 Low I Mod Troo TOTAL 4 tfz•n a roe 1 d era .rrp a,•,act pp„gHrp•gyp0yatemType. •.wr Ar.• .wan l.laar 1 tie• tea awaw Eta rrr r ..arrt APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL Job No. 1 Vale, Parlr at ta7 1« Mu "eM` - 4 o.7s 1a.M1 a of To.. 1421,wl on Vote tart A °A3 '" b wr wrr ae ENCROACH INTO DISTRICT AND USBR RIGHTS-OF-WAY. TREES PLANTS WALLS AND a 1w n...m Z_WEk A- M.. �•mr.^" ""' Zen" r"w "" 7w M. e`r`t;. ..rot. 5729 ue „7.6774 oat �: 0:75 7.73 PERMANENET STRUCTURES OF ANY KIND MAY NOT BE PLANTECS OR IN IN C.V.W.D. 4O O w L7 it it arra. 3 on for Vrn I.. n ON 746 M rn ear ur• IY Nwr 1 0. 04T Tw 0 2 0 0aT lY -_ 1« ` ' AL .Po _� 672a -�06 39e9a4 ae] IY o.7e _ _��6 •ra� 57 0 ,Ix T« oat i •wM. 1697 0. 1,.e + p TY o76 to AND USER EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT �-� I __ 4rar , 1 poi . i. •.,, r vlr J -57-29 0:8 70.•94M oa rw 0.76 -Tsai PERMIT FROM C.V.W.D. � c o CI 1 / 0. ».•» rM Zawl Eio rrr aw a 0. CC War I R O.w r 1Y M.p Wr.rr W a� ac Iw DATE BY _ e aaaa bin 0 a eo e77]7 ow rw o 76 2516 T P 1 rr+wr 200 D eD oex i« o e -o n WATER MANAGEMENT SPECIALIST W 0 110 ' -' �T I O� FLAN � DEVELOPMENT SERVICES SUPERVISOR � - V`IillIi1lA7ER GA�.GUL.ATION �'�AN � �IAT�R GA�.GU�- AN I �IATER GALGULATION PLAN 2,I�IAT�R GA�GU�ATION �. , tO r NOTE: IF NEEDED " STAKE SINGLE TREES 24'BOX AND 6 SMALLER.REMOVE NURSERY STAKES. N * IN TURF AREAS LEAVE A BARE AREA APPROX.4"AWAY FROM TREE BASE IN ALL DIRECTIONS ' v E� " DO NOT STAKE MULTI'S,UNLESS NEEDED GINGH TIES(2 EACH)DO NOT •� OVER TIGHTEN,ALLOW TREE TO MOVE SOMEWHAT TO BUILD DEPRE55ED WATERING BA51N N CALIF, PLANT 5HRUB5 MINIMUM OF 3' FROM TO REMAIN DURING PLANT Q Q Q a Q CURB IN MEDIAN5, 2 FROM GUR5/510EWALK5 E5TABL15HMENT PERIOD. IN PARKWAY5 BAGKFiLL MIX PER 5PEG5. 2 VY$LODGE POLE PINE TRH STAKE(2 EACH) 5ET ABOVE GRADE 2" TO 4" SET 2"TO 4"ABOVE GRADE a..... FINISH GRAD1= DEPRESSED WATERIN6 BA51N REMOVE FROM TURF AREAS LIMING FINISH GRAVING. =IIIII(=IIIIII IIIIII=IIIIII- NOTE: FIN15H GRADE III II I= ROOT ZONE UNTANGLE MATTED ROOTS BY IIIIII (IIIII= L005ENINCG ALL ROOT5 ® EDGE IIIIII=IIIIII IIIIII-IIIIII= IIIIII= =IIIIII OJ 1_ (IIII= BACKFn t MIX PER SPECS. OF ROOT BALL W/WATER FROM N c� IIIIII IIIIII= SEE SPECIFICATIONS. °. . -iumlT= -11115 i o III I=III iI=III II=IIII _ NATIVE UNDISTURBED 501L - IIIIII NATIVE UNDISTURBED 501L o o 3X ROOTBALL am) � FOR PLANT PIT SIZE REFER �f1 TO SPECIFICATIONS. .. ` 3X ROOTBALL E x V 00'r- TREE PLANT I NCG W/ DOUBL.E STA< I N6 SHRUS PLANT I N6 o 5. AB o- o o .. N.T.S. N.T.S. a? o E � � r- 0 1-- 0) 0 100a AISNIS FALI�i� THAT �- M I pJ 8'-12' VARIES � VERIFY W/ LANDSCAPE DE516NER 12 GAUGE GALVANIZED WIRE TYPIC.,AL PAINT WIRE TO MATCH WALL i ATTACH WIRE TO WALL WITH D_ GALVAN I ZED 50REW5 (TYPICAL) PAINT 5GREW5 AND WIRE � TO MATCH WALL a U� Q 50REW5 TO BE SPACED AT A 00 p < - c� Q Q Q MAXIMUM OF 6-0" ON CENTER PLANTING NOTES TRAIN PLANT ACRO55 WIRE TO 99 p Q Q�C�C�' FULL HEIGHT AND WIDTH W 1. Before any plants are planted, all planted areas are to have been graded JU - in an acceptable manner to asssure positive drainage per the grading notes. ,� < W 2. Separate all shrub/ground cover areas from lawn areas with 2"x 2' redwood DO NOT PLANT LO►"tB2 THAN TOP TAMP d Y�A113i-5ErrtE _ headerboard or 3 layers of redwood benderboard with staggered ,joints of R=BALL OR TOP OF ROOT BALL �� �' ZO FIN 15HED GRADE rT, (refer to planting plans). Stake headerboard with i x 2 x 12" NOT TO BE LOYeR THAN FINISH GRADE redwood �• - F.j.,� stakes spaced 46' on center maximum. "" 4.12 901,T1 3. Plant shrubs a minimum of 30' from all landscape light fixtures. _ - _ - 107 IFT 4. Where circumstances permit, plant no tree closer than IS' to an edge of paving or headerboard. 5. Remove all stakes from vines �o. Refer to planting . details. (-1 ��1 1. Whenever possible, use plant materials acclimated to the Coachella Valley. 'II_ 4` ,may S. Landscape contractor when tying vines is to use a drill to establish the NOTE: ESPALIER TO BE TRAINED IN A FAN 5HAFE �Q pilot hole to receive the red-head portion of the molly. a ^ 9. When tying vines or espaliers, wires should be spaced as follows: let (2) UNDISTEREIM NATIVE 501L TO PROVIDE FOR FULL WALL COVERAGE at I'-&' apart from finish grade, the next (3) at 1'-0' apart to make UNLESS NOTED OTHERWISE Q the top wire at 6'-0" above finish grade. Wires should be a minimum of ROOT BALL 8'-O' long center on plants. When vines or espaliers are closer than W 10' apart, use a continuous wire between both plants. 10. For protection of trees in turf areas leave a bare area approx. 4' away v from tree base in all directions. For plant pit size refer to specs. 11. WARNING Plant material listed may or may not have been approved by PALM TREE PLANT I N6 ESPAL. I ER TRAINING DETAIL. O W the Agricultural Commissioners office. -Landscape contractor, please D M �••� contact the developer for status of Agricultural Commissioner's approval N.T.S. N.T.S. or denial. Plant material not conforming with quarantine laws may be destroyed and civil action taken. All plant material is subject to inspection at the discretion of the Agricultural Commissioner's office. All plant material must be free from Red Scale (Aonidiella aurantii). 12. No shrubs are to be planted within 18" of hardscape, measured from center of shrub. w PALM TREE PLANTING NOTES LANDSCAPE INSPECTION SCHEDULE 1. Palms shall be planted using established planting procedures. Refer to a 1 palm tree planting detail. W 2. Palm tree root balls shall be trimmed or cut to ensure recovery from o FINI5H GRADE 1) Sleeving / Grading transplanting shock. tL A, a. Sleeve diameter, type depth and location V 3. Palm trees must be in a healthy condition at time of delivery. Palm X trees determined unhealthy or damaged at time of delivery or installation LU b. Soil surface drainage, elevations ations and trash ( including weeds 4 rubble) H shall be rejected by contractor and replaced by subcontractor at his m 00 expense' _ 2) Harder-ape ers a e / Bould / Cobble >111111 4. All palms shall be cleaned of excessive dead and ragged fronds or frond a. Sidewalk and wall layout Z -III= p stubble. Cut fronds should be cut to a maximum length of 6'. 5. Called out heights of palms sha I i be THE HEIGHT FROM TOP OF ROOT BALL H III= b. Utilities location TO BOTTOM OF LIVE FRONDS. LU _ -��I IIIII c. Boulder type, size, weight and placement 6. Palm trees to be properly watered in and soils properly tamped around the to ��__ _ IIIII=IIIIII-I(� root balls when planting, leaving no voids of soil around root balls. �_ _ _ _ - 3) Irri ations stem - Rough-In 1. Palm trees shall be planted vertically, unless noted otherwise. =IIIIII= ALL CAVITIES AND VOIDS g y g -IIS-'""- a. Trench depth and location 8, trunks should be rough with frond bases still securely attached. ARE TO BE BURIED p p SLOPED GRADE b. Pipe size and class 9. Trunks may not be totally skinned unless noted to do so. p 10. trunk bases may be skinned to a maximum height of 3'-4' (taller trees 6') Q c. Pressure test (125psi for & hours) 11. Skinned areas above the 6' level will be accepted, at the direction of the twill U Landscape Architect. Q 4) Plant Material (trees 4 shrubs) 12. Care should be exercised in the cabling during transport and planting so as A- a. Condition not to damage or loosen bark X FINISH GRADE b. Tyype M■T■� 13. Severe cracking or holes in the basal trunk area will not be acceptable. m C. Placement 14. One initial watering will be performed by subcontractor. Basin will be left N on each palm so subsequent watering can be performed by others. Basin 5) G•sroundcover (decomposed granite) is to be removed during finish grading. 15. Subcontractor to untie frond tops (60) days after planting ? a. T�yype '■■� a 16. Palm trees shall be planted a minimum of 18' away from building eaves. III II-_ _ =IIIIII b. Depth and spacing 0 1'1. It is recommended any palm tree planted within 5' of any walk, wall or W _ - G. COm action structure be planted with Deep Root root barrier to a depth of 2' minimum m =IIIIII-i i I I(= IIIII=IIIIII-IIIIII=I IT p M to protect against root damage. IS. Washingtonia robusta trunks are to have a minimum diameter of 14' measured - \ / (b) j=ina I M 4' high on trunk above finish grade. LEVEL EL 6RADE ALL GAVITIE5 AND VOID5 a. Irrigation NOTE: NOTE: ARE TO BE BURIED 1) Valves, boxes and wiring •o IT) Controller operation and schedule NO PALM TREE SHALL BE OUT OF THE ORIGINAL GROUND FOR MORE THAN BOULDERS IN CLU5TER5 ARE III) Sprinkler, bubbler and/or drip emitter type, flow (46) HOURS PRIOR to RELOCATION AND PLANTING. TO BE 5ET AT VARIED HEIGHT5 rate and quantity per plant iv) Overall operation T`i'PIC.AL. BOULDER PL.AGEI�ENT �) As-Built E b. Tree staking N.T.S. c. Overa I I BOULDER S� EDULE QUANTITY: � Q PLAN I PLAN 2 PLAN 5 PLAN SYMBOL 5I ZE APROX. WT. L i H T i NG L E E N D L i I I A 5Ix4'x4' ± 1-1/2 tons QUAN.AN i PLAN 2 QUAN AN 3 Qu N. 5-1-M. FIXTURE COMMENTS SPJ LIGHTING INC - SPJI6-01 C 32 WATT PLT ACCENT LIGHT FOR PALM TREES 4 Approved By: 1 2 O 1 B 4'x4'x3' ± I ton 1 2 1 1 120 VOLT,WITH LIGHT SHROUD VINES ON WALL$ MOUNT ON HADCO ROCKET F'EWA-POST J1 BLACK FINISH BA5E INFORMATION PROVIDED 0 1 1 1 1 120J LIGHTINGINC - SPJl6- D G 3'x3'x2' ± 3/4 ton 42 WATT PLT UP-LIGHT FOR CANOPY TREES BY: .JHA EN61 NEERI N6, INC. MOUNT ON HADCO ROCKET PER"1A-POST tW1 BLACK FINISH NORTHate: �1/I/U5 O 2 1 D 3'X2'x2' ± 1/2 ton THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT Scae: IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, NONE SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drown g LIGHTING SETBACK NOTES Y: LIGHTING NOTES: IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). FJH LANDSCAPE DE516NER CANNOT A55UME RESPON5181 L I TY FOR Locate light fixtures a min. of 4'-C' from edge of tree. TREE 4 PALM LIGHT FIXTURES SHALL BE ON SEPERATE APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO Job No. Underground Service Alert ANY PLANTS UTILIZED ON SITE WHICH ARE NOT 5HOWN ON THE Locate light fixutrea I'-0' from edge of palms. CIRCUITS AND ON PHOTOCELL ON/OFF. PERMANENET STRUICTURESAOFDANY KIND MAY NOTWBE PLANTE5 OR iINSt'AL/LEDSINNC..V.W.D. rJ AND USBR EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT w h 4010 Call: TOLL FREE PLANSAND HAVE NOT BEEN APPROVED BY THE AGRICULTURAL light fixtures In planter bade instead of lawn areas.At all times a conscious effort will be made to place PERMIT FROM C.V.W.D. > C-4 1-800 GOMMI5510NER'S OFFICE. These measurements are su erseeded onl when field SheetNo. Lli � 422-4133 p y DATE BY U conditions warrant change by Landscape Deslgner. WATER MANAGEMENT SPECIALIST Tp�2 LL TWO WORKING DAYS BEFORE YOU DIG DEVELOPMENT SERVICES SUPERVISOR I EMITTER SCHEDULE TREES ` f I I I ANT i SYM. NAME WATER � �-�_� SIZE EMITTER QTY. QTY. QTY. QTY. USAGE FACTOR "J U. --- } �� O O L 0.2 o - o � ,' � � � I Acacia smallll 24 box RAlnblyd 1402 I O o 7- 1 _ 5 Sweet Acacia o O I L o.2 0 Acacia aneura 24 box Ralnblyd 140 �� �� �� a 1 Mulga 0 _ I I - �> _ iI I I I ■ -��- DRIQ 7MNE _- _ _ �� � - 0Gerc►dlum f. 'Desert Museum' 24" box Ralnbird 1402 O I O O L 0.2 v� - 1C , - Palo Verde M 1 _ _....-_ DR ONE I I '1 Oleo Europeo 'Swan Hill' 24" box Rolnbird 1402 1 O 1 1 0.5 t5 I I , � 3I4' DRiP © _ O Fruitless 011ve Q V . 05I❑ 1 1 ! I BM BM e � i� L R 11 Pepper Tyree 24" box Rainbird 1402 O O M 0.5 1C ZI O I a � � � a I _ _ 1 q 3/4' DRIP I I �� _ +� 2G Z 12 ' 3/4' TREE - PALMS �� , � Q ��� ��v 2C 2 I I \ �i MTER _ 3/4' TREE I I + 3C 2.5 I 5YM. NAME 51ZE EMITTER OTY. OTY. OTY. OTY. USAGE PLANT - I - - , FACTOR I ION I ❑ I �-� - - �] 3/4' PALM = Ghamaerops humiils 24" box Rolnbird 1402 1 1 2 1 M 0.5 Mediterranean Fan Palm �_ ) 25 C �15 - - - - + it i 1 �/ -+- - - - - - - •p' • Washln tonta hybrid see plan Ralnbird 1402 2 2 2 2 H 0.5 3/4' PALM - - ❑ + / / I Hybrid Palm _- rn � o - - - - - - U*) , z rl- SHRUBS Q O �►I -_ - - - - - - WATER PLANT /1 00 0 s I �' Y \ 0 �\ - - - -�''SYM. NAME 51ZE EMITTER QTY. QTY. QTY. QTY. U5AGE FACTOR `� {'� N 0 `/ Q 1, U / BM ° rn Baffle a multiradlata 3 4 5 3 L 0.2 E o•° +1 II � y I gal XB-20PG-1032 � a � BM Desert Marigold co r = - - - r _ 4' SLE YE II i BM 1 \ BM/ - /- 7\/ CO co0 CO _ +12 BM / _ Bougainvillea Rosenka 5 9a1 XB-20PG-1032 3 2 1 2 1 1 0.5 .� o Q- _ - \� u �. X BCalliandro ala Fairy Duster�ica 5 gal. XB-20PG-1032 I 2 3 3 L 0.2 � . _ � a? o E BM O p ... Gaesolpinea pulcherrima 5 gai. XB-20PG-1032 O i O 1 M 0.5 _- _ 0 - - - - Red Bird of Paradise o 00 CL Cassia nemophila 5 gai XB-20PG-1052 1 2 3 1 L 0.2 Green Gassta zi �•�•G• Lantana montevidensis 'Purple' 1901 XB-20PG-IO32 1 1 4 1 M 0.5 DRiP ZONE_ 5/4" RESIDENTIAL METER- Q Purple Trailing Lantana --� 1=.O.G. L7Rli-'' 4 4 M 05 Lantana montevidensis 'New Gold' I gal XB-20PG-1032 5 6 New sold Trolling Lantana 5/4" RE51 DENT I AFL METER- Leucophyilum frutescens 'Green Cloud' S gal XB-20PG-1032 5 3 3 5 L 0.2 E 2 NORTH � Green Cloud Texas Ranger T�� I�t I T-TRTHFLANFLAN TNO Mulenbergla rigens 5 gal. XB-20PG-1032 4 3 3 O M O.5 Deer Brass ORuellta peninsularis 5901. XB-20PG-1032 3 1 3 1 L 0.2 Desert Ruellia I t 1 DESERT ACCENTSc� 0 Q 1 I � 51ZE EMITTER QTY. QTY. QTY. QTY. U5A�GER PLANT I �imao,nnaaa FACTOR W. SYM. NAME 1Q -- - „ - 'n���" � I I ION 36" (P XB-20PG-1032 1 I -_ 2 I L 0.2 Agave vilmoriniana Octopus Agave Dasylirlon wheelert 5 GAL. XB-20PG-1032 I I I I L 0.2 ,a 0 Desert Spoon I I C �• I ION 1 D 5 CAL. XB-20PG-lo32 2 3 1 2 L 0.2 D'RIF ZONE ( _ I �C I O Red Yucca loe parvlflora � 3/4' PRI10 JK 1 - 3/4' DRIP _ VINES _ 1®� + 2G 2 �� ��� 51ZE EMITTER QTY. aTY. QTY. OTY. UU55AGiE FACTOR I - 2C, 2 i �q® I 1 1 - 3/4' TREE I �` SYM. NAME I `V 3/4 TREE 12 ( 1 / 15 GAL. XB-20PG-1032 I O O M 0.5 ( W I - �� • ( '® I BouBougainvillea Barbara Karst' 1 ` ra inoe uliatera 3C 3 0 0- 3C 2.r.,� I - Gailtand a 15 GAL. XB-20PG-1032 0 I I O M 0.5 - - - - - - - I o o o Pink Powder Puff J 3/4' PALM � �. 3/4' PALM I / - - - - - - -+ - - - 5 and Sfi�ECIiCTiONS _ - - - - 1 �,, - - - - - - - ❑ REFER TO SHEET L i -2 FOR IRRIGATION DET�AiL 45 SLEEVE- rn 1 I I - 4' SLEEK I I 12 - - Underground Service Alert 10 , BM I _ / / FoE o Q Call: TOLL FREE U / I / ~ II 1 1-800 / --+1 BM rn t BM 422-4133 0 BM `� ° - 10 - -_ + TWO WORKING DAYS BEFORE YOU DIG ❑ -I� BM Q C - - - I1 GERALD FORD DRIVE A X / (O 5/4" RE51 DENTI AL METER- 5/4" RE51 DENT I AL METER- LU --- W '�• ` NORTHE NORTH Q T VC-1 LU FLAN IRRIGATION LEGEND o ® o � C�UJD �U�TER C,�LGS t� * I C\/WD WATER CAL CS � LAN M i L�I`� MODEL N0. DESCRIPTION NOZZLE RADIUS FLOW PSI PATTERN FRANK 51NATRA DRIVE SYMBOL MANUFACTURER = 6-1.95 GCF ail M.A.A.W.A. = 93.9 x Io x 1,906 x .62 / 148 = 89.01 CCF GPM 93.9 x .6 x 1,455 x ro2 / -146 SITE 0 62 / 148 / .9 = 18.13 CCF RAINBIRD 1400 SERIES TREE BUBBLER 1402 - 0.5 GPM 25 FULL O LOW WATER USING PLANTS---- E.A.A.W.A. = 93.g x .2 x 121 x .62 / 148 / .9 = 12.51 CGF LOW WATER USING PLANTS---- E.A.A.W.A. - 93.9 x .2 x 1,045 x - MOD WATER USING PLANTS---- E.A.A.W.A. = 93.9 x .5 x 641 x 62 / �48 / 9 = 2�.98 CCF MOD WATER USING PLANTS---- E.A.A.W.A. = 93.9 x .5 x '163 x .62 / 148 / .9 = 32.99 CCF DRIP ZONE RAINBIRD XB-SERIES DRIP EMITTER XB-20PC-1028 2 GPH 30 r"'+ / .9 = 4.90 CCF HIGH WATER USING PLANTS---- E.A.A.W.A. = 93.9 x .� x 95 x .62 / �48 / .9 = 5.�5 CCF ____ � HiGH WATER USING PLANTS---- E.A.A.W.A. = 93.9 x "I x 81 x .62 / 148 TE �� AF TOTAL ESTIMATED WATER USE = 45.45 CCF TOTAL ESTIMATED WATER USE = 56.8'( CGF RAINBIRD ESP-6LX+ WALL MOUNTED 6 STATION RESIDENTIAL CONTROLLER. LETTER DESIGATION REFERRS TO PLAN TYPE ONLY I "ASVF" SERIES S SIZE AS NOTED ON PLAN RAINBIRD ELECTRIC CONTROL VALVE FOR DRIP AREA NO 5GALE w/ XACZ-075 W/ RBY FILTER & +30psi PRESSURE REGULATOR a t r" "ASVF" SERIES ELECTRIC CONTROL VALVE FOR TREE BUBBLERS & LAWN, SIZE AS NOTED ON PLAN SASE INFORMATION PROVIDED W FL AN 2 CVI,UD UJATER CALC5 i=LAN -4 C\/UJD UJATER Cr4LC, RANBIRD E3Y: .�HA� EN&INEERINIS, INC. 6 x 1429 x .62 / 146 = 66."13 CGF 93.9 x to x 1,216 x 62 / 148 = 56.'(9 CCF JI KBI #MIP-1000-T BALL VALVE (LINE SIZE). REFER TO DETAIL ON IRRIGATION DETAIL SHEET -1 M.A.A.W.A. 93.9 x � A•, LOW WATER USING PLANTS---- E.A.A.W A. = 93.9 x 2 x �54 x 62 / �48 / 9 = 13.04 CCF LOW WATER USING PLANTS---- E.A.A.W.A. = 93.g x .2 x 66"i x .62 / 148 / 9 = 11.54 CCF 0 S, 16� 3211 Approved By: ---- x 5 x 596 x .62 / 148 / 9 = 25.�1 CCF MOD WATER USiNG PLANTS---- E.A.A.W.A. = 93.9 x .5 x 411 x .62 / -148 / 9 = 2031 CCF - - - • - PRESSURE MAINLINE PIPING USE SCHEDULE 40 - 3/4" MAINLINE MOD WATER USING PLANTS---_ E.A.A.W.A. 93.9 HIGH WATER USING PLANTS E.A.A.W.A. = 93.9 x x "19 x 62 / �48 / 9 = 4.18 GCF HIGH WATER USING PLANTS---- E.A.A.W.A. = 93.9 x .1 x '18 x lo2 / 14B / 9 = 412 GCF NON-PRESSURE LATERAL LINE PIPING - PVC CLASS 315 FOR DRIP, TURF AND TREE BUBBLERS- ALL 3/4" LATERAL BACKBONE GRAPHIC SCALE - 36.63 GCF 1/8 u=1 -0 0 NORTH Date: TOTAL ESTi1"1ATED WATER USE - TOTAL ESTIMATED WATER USE = 43.59 GCF I �I�O IRRIGATION POINT OF CONNECTION - RESIDENTIAL 3/4" WATER METER SOURCE. Scale: THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, PIPE SLEEVING SHALL OCCUR UNDER ALL MAJOR HARDSCAPE. SLEEVING SHALL BE 4" DIAMETER PIPE. SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn By: IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). F, ♦H NOTE : APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO Job No. cl INDICATES VALVE STATION & CONTROLLER NUMBER ENCROACH INTO DISTRICT AND USBR RIGHTS-OF-WAY. TREES, PLANTS WALLS AND 4010 W N THIS 'LAIN 15 D I GRAMMATI G ONLY. PERMANENET STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR INSfiALLED IN C.V.W.D. ALL I RRI 6ATI ON 5HO N O AND USBR EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT > MAINLINE LATERAL, u AL Y ES A'�� AN� OTHER INDICATES FLOW IN GALLONS PER MINUTE PERMIT FROM C.V.W.D. INSTALL ALL Sheet No. v A550G I ATED I fig'R 1 GAT I ON F=OU I FMENT Val I TH I N THE LIMITS 0� L�NIDSG�i�E �RE�• INDICATES ZONE TYPE Uj X DATE BY WATER MANAGEMENT SPECIALIST TI-1 1^L' INDICATES ELECTRIC CONTROL VALVE SIZE DEVELOPMENT SERVICES SUPERVISOR 1) 1 11 1 1 .� U U t ; v 1.00 IRRIGATION SYSTEM SCOPE OF WORK A. work In this section Includes providing all labor,material D. The Irrigation material shall Includo but shall not nacossorlly 4.00 IRRIGATION SYSTEM INSTALLATION PROC IPURES, I. ROUND VALVE BOX WITH GREEN BOLT- equipment,tools,permits,and tronsportation necessary to be limited to the followinga: DOWN COVER -(TAN IF IN SHRUB BED) 1 2 3 1 2 3 furnish and Install a comploto Irrigation system with 1009K A. Imlgatlon plan Is diagrammatic. Irr►gatlon laterals and mainlines „ „ HEAT BRAND BV ON Q E covorago of designated areas shown on the droAhgs and shown In hordscape Is for clarity only. Install all Irrigation ,n I.PLASTIC PIPE, VALVE BOX COVER IN 2" HIGH LETTERS. verify o spoclfiod heroin. a.Cxtondod from 100%vlrgtn polyvinyl chloride (PVC,). nt In planter bed areas. Landscape Contractor shall p erl y actual location of power source and controller before I Outside diameter of plastic plpo shall bo the same size an Irrigation Installation. Ely 9.The work*hall Includo but shall not be necessarily be limited as Iron y I a 1 ID TAG �1 ID TAG pipe,with plain end, All pope and fittings 1 2. FIWSFf GRADE, Z to the foliowin unless specified otherwise: g P shall be In accordance with the Society of Plastic 2 O WATER PROOF CONNECTION O WATER PROOF CONNECTION .- I.The Landscape Contractor shall visit the construction site, Industry Standards. 5. install all emitters and tree bubblers on uphill side of plant 4 (1 OF 2) 4 O 0 3. FULL FLOW BRA55 BODIED BALL VALVE- FULL PORT (1 OF 2) .,� -6 � P y material. Emitters shall be Install one(2")above finish reds, O 30-INCH LINEAR LENGTH O 30-INCH LINEAR LENGTH 'j > take all measurements,and obtain any other Information 9 necessary for a complete and conclusive bid. any emitter left at an unacceptable height shall be, rolnatalled PLAN OF WIRE, COILED'\ y P b. Pipe shall be continuously and permanently marked with at no cost to the owner. 4. 5GH. 40 PVG PIPE EXTENSION DIA. TO ALLOW 5 OF WIRE, COILED 2.Ordering,furnlshin ,and Installing materials for com lots the following Information:Manufacturor's name,normal pipe I ( FOR MOVEMENT OF HANDLE ON VALVE O REMOTE CONTROL VALVE: 5 a;. d tY 9 9 9 P s g O REMOTE CONTROL VALVE: tam Including piping,valves,fittings,backflow reventor size;PVC,typo,S.D.R.or pressure rating;and extrusion G.Verifyactual quantities and final location of lent material - RAIN BIRD ASVF a � 9 PP 9• 9 P , P - - - LENGTH AS REQUIRED. 6 RAIN BIRD ASVF G (Unless Specified Otherwise),dripper lateral lines,automatic date• with the owners representative before any installation of the = - _ _ = O = = O a Q a a � PP irrigation system. �� 5 INSTALL 6-INCH MIN. ABOVE t�INSTALL 6-INCH MIN. ABOVE >~ controller,and final adjustment of lines to Insure complete I(I I 5. 3/4 CRUSHED ROCK - 8 DEPTH. 7 HIGHEST POINT OF DISCHARGE c HIGHEST POINT OF DISCHARGE coverage. 6 O UV RADIATION RESISTANT . All plastic PG rn pipe shall be handle with care and shall be, D. Install Rainbird S acree as required to eliminate misting and 3 6. COMMON BRICK (2 REQUIRED). O UV RADIATION RESISTANT 11 PVC SCH 40 MALE ADAPTER PVC SCH 40 MALE ADAPTER - 5.Trenching,stockpiling excavation materials and refilling especially protocted from prolonged exposure to sunlight. overepray unto hardscope,streets,and structures. (1 OF 2) (1 OF 2) trenches, including compaction of back fill and Installation pO of sleeves. 7. 5GH. 80 NIPPLE TOE W/55 PVC, COUPLING O UV RADIATION RESISTANT O UV RADIATION RESISTANT d. Protect all PVC,plastic pipe from damage during construction 10.00 IRM16ATION MAINLINE AND LATERAL LINES: 6 :'t.;. ° '�'w: Q °00 8 PVC SCH 40 PIPE 8 PVC SCH 40 PIPE 4.Line voltage connections to the irrigation controllers and and storage. Q °00 ° 00 o goo° (1 OF 2) low vol control Airing from controllers to remote control A. Entire a tom shall be capped and pressurized to 100 PSI and 7 go°; o=• o 0 0 4 8. 2 CLEARANCE. (1 OF 2) �9e 9 � PP P o 0 0$0 p0 O FINISH GRADE/TOP OF MULCH valves. shall remain so for a two(2) hour period. Check all Joints and o ° o'° O FINISH GRADE/TOP OF MULCH 2.PVC FITTINGS: connections for leaks. Re air and correct as neceaaa o o�O° ' 9. PVG MAIN LINE PIPE. PVC SCH 4o ELLR1 �1 E P ry• O PVC SCH 40 ELL 5.Replacoment of unsatisfactory materials. a. Plastic fittin shall be ofpolyvinyl chloride(PVC),T e -° (1 OF 2) 1 OF 2 i,Schedule 40,N.S.F.and of IP5 solvent wold or scrowed S.THE ENTIRE SYSTEM SHALL 5E FLUSHED PRIOR TO INSTALLATION 5/4 IN TURF AREAS. I 10 PVC LATERAL PIPE 10 PVC LATERAL PIPE -J 6.Cleanup, Irnpoctlon and approval. 1 OF 2 I O type,Castor 5loano(sama manufacturer as of pipe). More OF SPRINKLER HEADS. Yherever necessary,Landscape Contractor Q o p0 Q o 2 IN SHRUB AREAS. ( ) (1 OF 2) `^ r- shall Install anti-drain chock valves(primarily on slope areas) to 0.. 8 10 N '!.Operational testa. threads are required,those shall be injected molded and q g0 . ego 10 �p allevtato low hood dralmage/erosion. °o o o o tV Schedule 80. All connections shall be solvent welded. Q.9oog0.go°oo° oo.09° 11 RBY FILTER & +30 PSI PRESSURE REGUI 9 00 6. 'As Built' record drawings,shop drawings,warrantios 80 .o.o 0 0 -•- O -�- �J Q O go 8° 080 V and guarantees. II.00 IRRIGATION HEADS: SECTION o' o $o° oQ o, °.@ o b. Plastic to plastic joints shall be,solvent-weld joints. a.Verifyunderground utility locations. Pipe solvent shall be .ohms-Manville "5lva"solvent weld O 1� 9r y A.Sprinkler heads along street curbs shall be setback 18' from f, cement. all street curbing. Sprinkler heads along Interior sidewalks �� rN C) 3 CO a \ / /� \ / shall be install 4" to b" from any edge of walks,ck•ivo or path. BALL Y l'lL Y 2.00 CODES,PERMIT'S,FEES,LICENSE AND INSURANCE: c. Plastic to metal Joints shall be with male adapters. the � B ANTI-51 PHON TREE/LAWN CONTROL \/ALVr A AN71-51 FHON XERI CGATI ON CONTROL \/ALVr � � A.All work and materials shall be to full accordance with the male adapter shall be hand tightened,plus one turn with a S. Irrigation heads on a riser will not be permitted along - E R -0 latest rules and regulations of the National Electric Code,the strap wrench. Joint compound shall be,Permatex Type II flatwork. Refer to legend for height of all pop-up sprinklers. N.T.S. N.T.S. N.T.5. CL v- 0) Plumbing Code,published by the Western Plumbing Officials (Only Schedule plastic may be threaded). CO C 00 •L Association;and other applicable State and local laws or C. Adjust entire system as necessary, Including locations of the ( Q O sprinkler heads,radius of throw,and adding sprinkler heads If LEGEND �- regulations. Nothing In those Drawings or Specifications Is to 5.REMOTE CONTROL VALVES: if necessary for the Intended operation and 100%coverage be construed to permit work not conforming to these codes. a. 0 N All valve locations are shown schematically on Irrigation plan of all planted areas. i. BROOKS #I100 10"XIO" ROUND VALVE E and need to be verified with and approved by Owner's Reprosentot►vo/6aneral Contractor. Irrigation valves will not BOX. HEAT BRAND "FV" ON LID IN 2" rn to (1)8.The Landscape Contractor shall promptly notify the Owner's be allowed in grass areas unless approved by Owner's HIGH CHARACTERS. TAN COLORED BOX LID. c l Roprosentattve/6oneral Contractor of any work outlined on Reprosentativo/boneral Contractor. 12.00 AUTOMATIC,CONTROLLER: \ / O " the plane or spocfficatlona that Is not in accordance with F X 2. FINISH GRADE. 1:applicable laws,codes,and regulations. Without such A. The Landscape Contractor shall be responsible for the final O FINISH DE/TOP OF MULCH - 0 O notice and appropriate modifications by the Owner's 4.VALVE BOXE5: electrical connection from the power source(SY OTHERS) to I.D. TA (SEE NOTES). I �- �i o Q.n 3. GHRISTY'S G. o ReprosontatWe,the Landscape Contractor shall aesvme full a.Valve boxes shall be green Carson No.ale In lawn areas controller as Indicated on plan. Final controller location Q , roe onatbili for an work executed which is contra to and tan Carson No.al0 In shrub aroaa. Mark lid shall be verified with and approved by Owner's Representative , „ 2 \i �- M P y 4. 3/4 GRU5HED ROCK. 6 DEPTH. 2U -UP SPRAY SPRINKLER such laws,codes,and regulations. "Irrigation Control Valve". Install 2" above grade In /6orierai Contractor. G.License: groundcover areas wherever possible, 5.Attach a typewritten legend froido each controller door,stating 5. AG PRODUCTS 3/4"-B BALL VALVE. 2 3 (0 G the areas covered by oath remote control valve. All work shall be performed by a -Z'i Gallfornla licensed 6. PVC, SCH. 40 MALE ADAPTER 1/2-INCH MARLEX STREETm Landscape Irrigation Contractor. 5.VALVE CONTROL WIRE: I Z ELL(5) a. Valve control wire shLJI be installed per code. Wherever 15.00 COVERAGE TEST, 3 1. SALGO A/R FLEXIBLE PVC H05E 4 DG° T7.G: D.Permits and Inspection w: possible,plo wire 3 PVC LATERAL PIPE in common trench with mainline. Wire MINIMUM 3 FOOT LENGTH O The Landscape, shall obtain,coordinate,and pay for shall be UL-approved for direct burial In ground,size A.when the sprinkler system is completed,the Landscape _The e C any permits,fees,and agency Inspections as required and #14-1 NNLE55 SPECIFIED DIFFERENTLY ON IRK16ATION PLAN) Contractor, In the presence of the Landscape Architect 5. 5GH 40 - CIO DEGREE ELBOW. O PVC SCH 80 RISERS = _ _ I I _ I _ _ submit all certificates of approval upon completion minimum with maximum volts drop of 5%between valve or Owner's Re, resentatNe shall perform a test which I - " - _of work. Indicates 90 op p p _ I. RAIN BIRD XB-##-1032 EMI PP PTiER 10 MIN and controller. Common ground wire shall have white the water coverage afforded the planting areas Is complete, _ Q. RIGID PVC, PIPE. 3 LENGTH IIII=IIII I I((=III(-)III see emitter schedule for specific emitter E. Insurance: insulating jacket;control wire shall have Jacket of color adequate,and does not sprinkle any structure walls,walks ���� = O PVC SCH 40 TEE OR ELL 2. BowSMITH POLYFLEX RISER The Landscape,Contractor shall carry all Worker's Compensation, other than white. Spl►cea shall be,made with#2006-5 or paved areas. The Landscape Contractor shall furnish all I I(--IIII-IIII-I I( +� „ IIII IIII= (I-ENGTH A5 REQUIRED). public. liability and property damage insurance as required Suchanon lice ca s and SM#55?6 5cotchiok seal packs. materials and perform all work required to correct any 7 I IN LAWN AREAS. P P P g q sp P P all applicabl Inadequacies disclosed. IIII 2" IN 5HRU5 AREAS. 5. FINISH GRADE. applicable codes,regulations,and the 6aneral Contractor. ^ F.Site Verification: 5LEEVIN6: 14e C .00 GLEAN UP, 6 q 6. > 4. PVC, FITTING (5 x S x I/2" FIPT). a Landscapontractor shall provide all Irrigation NOTE: U5E TEFLON TAPE ON ALL MALE 4 5 5. PVC, PIPE (DEPTH PER DETAIL 6-ON THIS SHEET). commencement Prior to of work,the Landscape Contractor shall sleeving (Unless Specified Otherwise) under all hardecaps. A.During construction,the Landscape Contractor shall keep + °° x PIPE THREADS. verify all conditions and dimensions shown on the plans necessary Coordinate all underground PVC,sleeve*work with the promises as clear as possible of material and debris. to achleve the intended designon'of the Irrigation system, An g 8 °�•'°s °°�eo°e•"� l �F 1 9 � y Owner's Representative/6aneral Contractor. All sleeving discrepanctos shall be reported Immediately to owner's required shall be Schedule,40 PVC,pipe and shall be a S.Upon completion of the work under this section,the Landscape • Representative/General Contractor. q P P Contractor shall remove from the promises all surplus material, FLUSH TO BE LOCATED AT THE END 4 5 3 6 • minimum two sizes larger than lateral or mainline piping. tools,equipment,rubbish,and debris resulting f,on his work, OF ALL DRIP LATERALS. ,, w and shall leave the installation site in a clean,neat condition. (�1 b. Coordination: 1 ll1 \Y/ The Landscape Contractor is responsible for coordinating this 1=LUST T AL Y � F-UF 5FR work with all other trades. This Includes,but Is not limited 6.00 IMPLEMENTATION: AY DETAIL DR I F EMITTER A55EMBLY to,provisions for raceways and sleeving as well as water and E D owor sources. All Irrigation work shall be coordinated with0 N.T.S. N.T.S. N.T.S. P 9a A.Prior to Installation,Landscape Contractor shall verify static and approved by Owner's Representative/boneral Contractor. pressure at project afte. This system is designed to operate from 22 gpm at a maximum static pressure of 65 MI. H.Scheduling, Notify Owner's Representative/boneral Contractor at the alto The Landscape Contractor shall notify Owner's Representative/ Immediately of any discrepancies and proceed as directed. boneral Contractor not loss than two(2) working days in advance HOUSE SERVICE PIPING of any requested observation. B. If Irrigation system Is to operate from the golf course,verify (D ELECTRICAL JUNCTION 5OXV1 all site conditions: grading,static pressure,and point of P.O.G. TO HOUSE SERVICE LINE size as required I. out Of Work:La connection for remote control valves. y ROUND PLASTIC VALVE BOX 6 O IRRIGATION CONTROLLER - WALL MOUNTED I.The Landscape Contractor win stake out the irrigation SCH 40 COMPRESSION TE 5 LEGEND CONTRACTOR TO PROVIDE LAMINATED COLOR system as shown on the drawings. These areas shall be C.Coordinato the Installation of all Irrigation materials, CODED MAP LOCATED t SECURED INSIDE chocked by the Landscape Contractor and Owner's Representative Including pipe,with the Landscape Drawings to avoid interfering OR PVC SST TEE NON-PRESSURE LATERAL LINE PIPING. (e. Sta. 1 - Tree Bubbler,0 o g• Sta. 2 - Shrub Dr(p) /6 ral Contractor before construction is started. Any with the planting of trees,shrubs or other plant material. 0 00 0 0 -i I I I=IIII + # of STATIONS LEGEND D. 0 0 e SEE IRRIGATION LEGEND FOR MAKE, MODEL, changes,deletions shall be determined at this oo °0 000 _ O2 PRESSURE MAIN LINE PIPING check. 0 =III( IIII=IIII O CONDUIT - PVC W D. All Irrigation lines,valves,and wiring shown on plan under METER BO o 0 paving are schematic only. Install these items in planting 0 0 O 00 p IRRIGATION SYSTEM SHUT-OFF GATE VALVE -_ � CONTROL WIRE-5 - TAPE AND BUNDLE 2.The Landscape Contractor Is responsible for adherence to areas whenever possible,except when lines must cross paving to 0 no 00 000 FROM DOMESTIC WATER SOURCE _)III EVERY 10 FEET. INSTALL ADJACENT O W Degree PVC Sweeps 0 00 0 0 0 0 0 •SEE NOTE IIII- TO PRESSURE MAIN LINE. the contract documents relative to equipment type,size connect planting areas or unless noted on plan. 0 00 0 o a o0 0 0 O 24 VOLT OUTPUT installation,and location. However,the Landscape contractor 0 93000000 0 PEA GRAVEL ° ..shall make minor adjustments,modifications,and revisionsPEA 2 GU. FT.) I O4 PROVIDE 2" DEPTH OF GLEAN BAGKFILL. j E. Irrigation designer shall rove all design changes due to site 0 °• ° NOTES: o to the Irrigation system,as required,to conform to size g aPP 9^ g 4 O SEE IRRIGATION SPEGIFIGATION5 FOR I. Common wire to be white and control wire to be conditions and to provide conaiatent IOOAS coverage of plan changes,or scaling errors in irrigation plan to guarantee BAGKFILL AND COMPACTION IOOAS sprinkler coverage. Irrigation Contractor shall assume full 2 120 VOLT INPUT black unless otherwise noted. (� all Irrigation areas. responsibility pr for from coverage when infield changes are made MINIMUM (1) PIPE SIZE REQUIREMENTS. 3 2. No splices shall be made between controller and without approval from Irrigation designer. S. Any deviation from the contract documents shall be verified LARGER THAN METER � BAGKFLOW 3 remote control valves unless otherwise noted. with the Ownarb Representative/6aneral Contractor prior F. Irrigation designer shall not be responsible for Improper O FINISH GRADE. 3 3. All exposed, wire to be installed in conduit, unless UL to any Irrigation system Installation. The Landscape operation of system due to Landscape Contractor not Installing °• •• FINISH CsRADE Contractor shall take full responsibility for adjustments to •• °' 4 approved UV resietent direct burial wire is used- * MINIMUM BAGKFILL DEPTHS FROM FIN15H -Low voltage Only. P �! ) the Irrigation system per plan,poor workmanship,incorrect •• 4. Control wire to be minimum AI.UC� #14, one control an material or work that is not roved. 6, GRADE TO TOP OF MAINLINE 17 wire to each controller, controller to be rounded as y aPP pipe sizing than specified on plans or inadequate static pressure from water source. it shelf be the responsibility of the Landscape 24" FOR PIPE SIZES 3" AND LARGER �/�/� /��/�� g 5.00 SUPERVISION And WORKMANSHIP: Contractor to notify the Irrigation designer of any site or equipment PVC MALE ADAPTER (TYP.) 15" FOR PIPE 51ZES 2 1/2" AND SMALLER. !/��//��/�� /%�//\�/ ///��//� per manufacturers specifications. ////i /�\//�\//, /�\/ changes on approved irrigation plans prior to any Installation 5. 120 volt power to be provided by others; all shall The Landscape Contractor,personally or through an authorized and of the Irrigation system so as to provide design modiffcattons. be according to local code. aompetont representative,shall supervise the work constantly,and SCH. 40 PVC, PIPING %. Contractor will connect cotroller to power source and shall as for as poaaibla keep the same Forman and workman 6.Provide Owner or his rapreaentativo with all operating instructions,ctio , ,¢ 3 supply labor, equipment 8 material needed for said on the job from commencement to completion. The workmanship of tools,keys,etc.as required for operation and maintenance 3 supply the entire job must In every way be First class,and only of the irrigation system. EXISTING ER METER connection. Owner to power. Contractorr to field verify location of power source prior to submitting experience an competent workman will be,allowed on the job. CURB, WALK, ETC. Bid. Install per local code. H.Landscape Contractor shall also provide Owner with two (2)seta of "As Built Drawings" of the Installed irrigation system. J N 4.00 GUARANTEE: I.Record accurately on one set o4 reproducible prints of the POO DETAIL TRE-NC H I NG GONTROLLER4NAL.L MOUNTED drawings,a record plan drawing showing any changes. Keep It A.All material and workmanship shall be,guaranteed and shall perform to the complete satisfaction of Ownerb Representative/ up-to-date as the project Is under construction. In addition, N.T.S. N.T.5. N.T.S.bsnorai Contractor for a minimum of one year after completion and dimension for two permanent points of roforonce the location of the pressure supply line,valve plug tees,and control wire. acceptance of the Job. During this guarantee period,all required repairs and adjustments,Including adjustment to grade,shall be •cd made without additional expense for repairs to other work. O '7.00 SACKFLOW PREVENTER: LEGEND 5.All .� damage to paving,planting,structures,and other A.Provide and install backflow praventer unit (Unless Specified LEGEND i. ELECTRIC EMITTER CONTROL VALVE ASSEMBLY. Improvements due to settlement of Improperly compacted Otherwise)per State and Local Health Department codes and trench backfiII shall be promptly repaired to the satisfaction of current listings. 5ackflow 2. BACKBONE LATERAL - PVC, GLASS 200 PIPE.protection unit shall be located O RAINBIRD 1402 BUBBLER.Owner's Representative/boneral Contractor at no additional expense. In such manner as to allow for screening by plant material. 3. FLUSH VALVE. SEE DETAIL G THIS SHEET Refer to plan for location. PVC, RISER - 5GH. 80 4. DRIP LATERAL - PVC, GLASS 515 PIPE. O G.This guarantee excludes theft,vandalism,natural dlsaater,or work the system by others after final acceptance. The 8.00 TRENCHING= 8 O PIPE SIZING CHART Landscape 5. BOUNDARY FOR DRIP VALVE ZONE. ape Contractor shall check,clean,and adjust all Irrigation PVC LATERAL PER PLAN. ro. SHRUB EMITTER DETAIL (TYPICAL). lateral lines and othorwlso Insure adequate operation of the A.Trenching shall be free of all rocks,debris,and sharp 5 TREE PIT PER PLANTING DETAILS. 7. MAINLINE system throughout the guarantee i articles. Back filling shall be accomplished In a manner to SET AT EDGE OF SET AT�of O 7 PIPE SIZE MAX. ALLOWABLE FLOW y g g period. Insure no further settlement of ditch and to match adjacent SOT�-i- Roar�- O FINISH GRADE 4 O grades. back filling shall be done until scheduled �� °� •� 5 1/2' 5 GPM observation are made. 2 O TREE OR PALM ROOT BALL O 5.00 MATERIALS: 2 I 8 3/4' 10 GPM � M 5.Gap or plug openings as pipeline to assembled to prevent entrance O TREE OR PALM TRUNK �� ' _� �� A.All work and materials shall be in full accordance with the /, O of dirt or obstruction by foreign objects. Remove cape or plugs when 6 7 6 ` 1" 16 latest rules and regulatCodes,published of the National Electric CodePlumbing the necessary to continue assembly. THIS IS ESPECIALLY CRITICAL ® SET ON UNDISTURBED NATIVE SOIL _� �� -�� U Uniform Plumbing Codes,published p the Western Plumbing FOR DRIP LATERAL LINES. 3" ` O Z GPM Off ictale Association;and other applicable State or local laws � � ____ _ � 10 MARLEX 90 DEC.. STREET ELL. JOINT 1-1/4' 2ro GPM .0 or regulations. Nothing in those Drawings or Specifications la C. Install mainline pipes, lateral pipes,and wiring In common .I-I f�Tl� I 1-1/2' 40 GPM �., to be, construed to permit work not conforming to these codes. trench wherever possible. Mainline pipe shall have a minimum 3 *00 of 24" cover(50" cover under roads and streets). Lateral pipes -1 11' 2' (00 GPMclliiOI B.All equipment shall be as listed In the legend,details,and shall have a minimum of 12" cover(16" cover under roads andG E N E R A L IRRIGATION N 0 TE S 11= 3 specified heroin. Install all equipment per details and streets). Provide a minimum of d e sand all around pipe f 5 =III= 3 -REFER TO PLANT LIST / EMItTER SCHEDULE specifications sal manufacturer's y Owner's Roorn. Any runs under streets,driveways,and vehicular accoTaps a areas. / FOR EMITTER MODEL * S G H S substitutions shall be approved by Owner's Representative/General Provide a minimum 24" cover for all wiring. Tape and bundle THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE - aq D P R Contractor in writing. Any unspocffled equipment shall be wiring at 10' intervals. Tie a loose 20" loop in all wiring at ongosMAXIMUM FLOW DEMAND SHOWN ON THE IRRIGATION DRAWINGS AT THE METER OR POINT OF 4 2 EACH PLANT SPECIES ANTHI SHEET. replaced at Landscape Contractor's expense. of direction greater than So". Untlo all loop after all tonne tions CONNECTION. THE IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO have been made. CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE -REFER TO EXAMPLE BUBBLER EMITTER LATERAL DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO / SYSTEM - DETAIL SHEET LI-2. G.When the quaky is r larger call for materials or construction of THE OWNER'S AUTHORIZED REPRESENTATIVE. IN THE EVENT PRESSURE DIFFERENCES ARE NOT • PERCOLATION TEST TO BE DONE FOR DEEP WATERING �► a `ter'quality or lager size than ree{ulred the above 10 4 igE81ILT8T!!fi'e1t1€D 1O L 4SC4PE DESIGNERREPORTED PRIOR TO START OF CONSTRUCTION, THE IRRIGATION CONTRACTOR SHALL ASSUME TNI:� mentioned rules and regulations,the Specifications shall FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. (j �_ �� take precedence over the requirements of the sold rules and regulations. The Landscape Contractor shall furnish without 120 VOLT ELECTRICAL POWER OUTLET AT THE AUTOMATIC CONTROLLER LOCATION SHALL BE any extra charge any additional material and labor when required PROVIDED BY OTHERS. IT SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO DRIP LAYOUT by the compliance with these rules and regulations,though the work MAKE THE FINAL HOOK-UP FROM THE ELECTRICAL OULTLET TO THE AUTOMATIC CONTROLLER. f TRFE IRRIGATION DFTA I L K be not mentioned in these particular Specifications or shown on the THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS iS ll- Drawings. FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS. AVOID ANY N.T.S. N.T.S. CONFLICTS BETWEEN THE SPRINKLER SYSTEM, PLANTING AND ARCHITECTURAL FEATURES. P THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO ALLOW FOR NO OVERSPRAY IF ANY ONTO WALKS, ROADWAYS AND/OR Approved By: BUILDINGS. THIS SHALL INCLUDE ADJUSTING EACH VALVE TO OBTAIN THE OPTIMUM OPERATING a \ / t--� PRESSURE FOR EACH VALVE STATION. BA5E INFORMATION PRO X I Dr-D DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS B I : JHA ENG 1 NEER I NO, INC. NORTH TH Date: OBVIOUS IN THE FIELD THAT OBSTRUCTIONS, GRADE DIFFERENCES OR DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. SUCH NO OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S Scale: AUTHORIZED REPRESENTATIVE. IN THE EVENT THIS NOTIFICiA11ON IS NOT PERFORMED, THE THESE PLANS HAVE BEEN REVIEWED BY THE COACHELLA VALLEY WATER DISTRICT IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. IN ACCORDANCE WITH WATER CODE TITLE 7, DIVISION 1, CHAPTER 3, ARTICLE 10.8, INSTALL ALL PIPE MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE T SECTION 65597 ET SEQ. REQUIRING EFFICIENT LANDSCAPE AND IRRIGATION DESIGN Drawn By: TEFLON PIPE DOPE ON ALL PVC MALE PIPE THREADS ON ALL SPRINKLER SWING IN COOPERATION WITH THE LOCAL GOVERNING AGENCY (CITY OR COUNTY). FJH SWING JOINT AND TAPE OR Underground Service Alert APPROVAL OF THIS DRAWING BY C.V.W.D. STAFF DOES NOT CONSTITUTE APPROVAL TO C RO F AH INTO DISTRICT AND USBR RIGHTS-OF-WAY. TREES Job No. ORE y IT ►S THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO BE FAMILIARIZED WITH ALL ENCROACH , PLANTS WALLS AND GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS PERMANENET STRUCTURES OF ANY KIND MAY NOT BE PLANTED OR INSTALLED IN C.V.W.D. 4OlO o� Call: TOIL FREE WORK WITH THE GENERAL CONTRACTOR AND OTHER SUB-CONTRACTORS FOR THE LOCATION AND SB EASEMENTS OR RIGHTS-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT 1-800 AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING, PERMIT 422-4133 Sheet No, IN ADDITION TO THE SLEEVES SHOWN ON THE DRAWINGS, THE IRRIGATION DATE BY TI-2 CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF CONTROL WIRE SLEEVES OF WATER MANAGEMENT SPECIALIST TWO WORKING DAYS BEFORE YOU DIG SUFFICIENT SIZE UNDER ALL OTHER PAVED AREAS. DEVELOPMENT SERVICES SUPERVISOR