Loading...
HomeMy WebLinkAboutPSPA22-0049 PLAN.pdfaccess 3'-6"WD 5'-0"WD B E N C H 12"WD 11'-4" 4'- 6 " 17'-5" 11 ' - 1 0 " 3'-10" METALLIC COMPONENTS. RI C H A R D S O N R E S I D E N C E 77 - 9 8 0 W I L D C A T D R I V E , S U I T E 2 PA L M D E S E R T , C A CA - C - 5 3 # 1 0 1 0 4 0 3 76 0 . 3 4 5 . 9 7 0 0 75 7 3 0 A X I S C T PA L M D E S E R T , C A POOL DETAILS SURFACE AREA: PERIMETER: SIZE:X DEPTHS:TO TYPE: SURFACE AREA: PERIMETER: SIZE: JETS QTY: SPILLWAY TYPE: SPA HEIGHT: N FINISH: EXPANSION JOINTS: SQ. FT: CANTILEVER: STEPS: STEP FACE: DECK DRAINS: SPA DETAILS DECKING ACCESS: ELEVATION: TYPE: CONC. REMOVAL: SOD REMOVAL: 6" R.B.B: EXCAVATION / STEEL 12" R.B.B: 18" R.B.B: 24" R.B.B: 30" R.B.B: TAN SHELF DEPTH: ROCK POCKETS: CENTERS: FILTER: PLUMBING SIZE: POOL PUMP:SIZE: BOOSTER PUMP:SIZE: ADD'L PUMP:SIZE: ADD'L PUMP:SIZE: HEATER:SIZE: CONTROL SYSTEM: SUB PANEL AMP: ADD'L OUTLETS: GAS LINE FT: FOUNTAINS / SPRAYHEADS: SHEER DESCENTS: POOL LIGHTS: PLUMBING: SPILLWAY TYPE: GUNITE SPILLWAY SIZE: DAM WALL WIDTH: MISC: COPING TYPE: MASONRY R.B.B. FACE: REPLACE ACCESS WALL: SPILLWAY TYPE: SPILLWAY SIZE: FIREPIT: BBQ: EQUIP. WALLS: RETAINING WALLS: PLANTER WALL: FENCE TYPE: FENCING HEIGHT: REMOVE & REHANG: GATE TYPE: PEBBLE COLOR: PEBBLE / PLASTER FITTINGS COLOR: STEP TRIM: PLASTER COLOR: UMBRELLA SLEEVE: EST. START: EST. COMPLETION: S C A L E : 1 8 " = 1 '-0 " SPA FACE: SPA LIGHTS: SAND & VISQUEEN: WATERLINE MATERIAL: 400,000 BTU HEATER. ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED. 4'-0" MIN. CLEARANCE TO OPENING WINDOW 55' - 11 2" POLYPROPYLENE GAS PIPE 3 4" PVC ELECTRIC CONDUIT WITH #10 AWG WIRE TO SUBPANEL POOL EQUIPMENT SUBPANEL WITH 36" CLEARANCE AT FRONT GUNITE 392 SQ. FT. 98 LN. FT. 33'-0"13'-0" 3'-6"5'-0" 7'-0"7'-0" 49 SQ. FT. 28 LN. FT. 4 HYDROTHERAPY JETS -0- N/A 1013 SQ. FT. BROOM YES 98 LN. FT. NO NO NO 60" BOBCAT LEFT SIDE YARD NO NO 12" WATER DEPTH NO AS NECESSARY PENTAIR PENTAIR PENTAIR 520 VARIABLE SEE SELECTION 30 AMPS 55 LN. FT. 4 - GLOBRITE COLOR LED 1 - GLOBRITE COLOR LED TILE DAM WALL 15 LN. FT. 10-3/4" WIDE BROOM FINISH CONCRETE TILE PER PLAN TILE N/A N/A N/A N/A N/A N/A POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED ANTI-ENTRAPMENT COVERS TO BE HYDRAULICALLY BALANCED 811 DIG ALERT - BEFORE DIGGING SUBPANEL SCHEDULE 1 2 3 POOL PUMP POOL LIGHT 20 AMP 208 1PH 15 AMP 1PH - GFCI 2019 California Residential Code (CRC), is based on the 2018 International Residential Code 2019 California Electrical Code (CEC), based on the 2017 National Electrical Code (NEC) 2019 California Mechanical Code (CMC), based on the 2018 Uniform Mechanical Code (UMC) 2019 California Plumbing Code (CPC), based on the 2018 Uniform Plumbing Code (UPC) 2019 California Green Code (CGC), written by the California Building Standards Commission (CBSC) 2019 California Energy Code (CEC), written by the California Energy Commission (CEC) SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI-COVERS 10" ASME / ANSI APPROVED ANTI-ENTRAPMENT COVERS TO BE HYDRAULICALLY BALANCED 1- PENTAIR 420 CARTRIDGE FILTER 1- PENTAIR INTELLIFLO VARIABLE SPEED PUMP 1- PENTAIR MASTERTEMP 400,000 BTU HEATER 1- 30 AMP SUBPANEL 1- 300 WATT POOL LIGHT 1- 100 WATT SPA LIGHT SPA / HEATER / PUMP SHALL BE INSTALLED PER MANUFACTORS RECOMMENDATIONS AND IN ACCORDANCE TO LOCAL REGULATIONS EQUIPMENT SCHEDULE *NO OUTDOOR SURROUNDING LIGHTING OR LOW VOLTAGE LIGHTING *NO OVERHEAD UTILITY / SERVICE LINES *DECK BONDING - B WATERLINE: T.B.S. S E L E C T I O N S STONE TILE CONCRETE GROUT CONTROL SYSTEM INDOOR CONTROL PEBBLE / PLASTER PAVERS QUARTZITE STANDARD GREY NONE T.B.S. SCREENLOGIC INTERFACE MINI PEBBLE: T.B.S. MISC: WD = WATER DEPTH SB = SET BACK A B B R E V I A T I O N L E G E N D S = SKIMMER A = AUTOFILL PALM DESERT MUNICIPAL CODE REQUIREMENTS: APPROVED TEMPORARY SANITARY FACILITIES (i.e. CHEMICAL TOILETS SHALL BE ON THE CONSTRUCTION SITE PRIOR TO REQUEST FOR FIRST INSPECTION), (HEALTH AND SAFETY CODE, SECTION 5416) CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS. (ORDINANCE NO. 262 OF THE PALM DESERT MUNICIPAL CODE) STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT FOR WHICH THE PERMIT IS ISSUED. ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR THIS PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS ON FILE WITH THIS OFFICE. THE PUBLIC RIGHT-OF-WAY SHALL BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES. (PALM DESERT MUNICIPAL CODE, CHAPTER 8.02) CONSTRUCTION HOURS: OCTOBER 1 THRU APRIL 30 MONDAY - FRIDAY 7:00AM - 5:30PM SATURDAY 8:00AM - 5:00PM SUNDAY NOT ALLOWED GOVERNMENT CODE HOLIDAYS NOT ALLOWED MAY 1 THRU SEPTEMBER 30 MONDAY - FRIDAY 6:00AM - 7:00PM SATURDAY 8:00AM - 5:00PM SUNDAY NOT ALLOWED GOVERNMENT CODE HOLIDAYS NOT ALLOWED VIOLATION OF THE ABOVE WORK HOURS IS A CITABLE OFFENSE UNDER PALM DESERT MUNICIPAL CODE SECTION 9.24.070 STEP TRIM:NO N/A TO MATCH N/A YES - PER PLAN N/A LO T 4 5 Q 2 @ M O N T A G E D A T E :04.06.22 AT EXCAVATION HP = HIGH POINT STUBS:N/A EASY TOUCH 4 W/ SALT 2-1 2" SUCTION & 2" RETURN MISC. T-24 ENERGY REQUIREMENTS IN PLANS TO INCLUDE BUT NOT LIMITED TO: a. TIGHT FITTING POOL COVER b. SUBMIT CF-2R-PLB-03-E AT FINAL INSPECTION c. CONSTRUCT 36" PIPING BETWEEN HEATER & PUMP FOR FUTURE SOLAR WATER BONDING AT THIS LOCATION ACCESS GATES THROUGH THE ENCLOSURE MUST OPEN AWAY FROM THE SWIMMING POOL, AND MUST BE SELF-CLOSING WITH A SELF-LATCHING DEVICE ADDRESS NUMERALS SHALL COMPLY WITH PALM DESERT ORDINANCE 1265 (PDMC 15.28) (b) ALTERNATE MEANS. EQUIPOTENTIAL BONDING CONDUCTOR MEETING THE FOLLOWING: 1. 8 AWG BARE SOLID COPPER BONDING CONDUCTOR 2. THE BONDING CONDUCTOR SHALL FOLLOW THE CONTOUR OF THE PERIMETER SURFACE. 3. LISTED SPLICING DEVICES 4. BONDING CONDUCTOR SHALL BE 18 TO 24 IN. FROM THE INSIDE WALLS OF THE POOL 5. BONDING CONDUCTOR SHALL BE SECURE WITHIN OR UNDER THE PERIMETER SURFACE 4 TO 6 IN BELOW THE SUBGRADE METALLIC PARTS OF THE POOL, OUTDOOR SPA, OR OUTDOOR HOT TUB STRUCTURE SHALL BE BONDED TO THE EQUIPOTENTIAL GRID UNDERWATER METAL FORMING SHELLS.METAL FORMING SHELLS AND MOUNTING BRACKETS FOR LUMINAIRES AND SPEAKERS SHALL BE BONDED TO THE EQUIPOTENTIAL GRID 18 TO 24 IN. FROM INSIDE WALL OF POOL 8 AWG BARE SOLID COPPER PERIMETER SURFACE EQUIPOTENTIAL BONDING PERIMETER SURFACE SECTION 680.26(B)2(b) AS NECESSARY X 400,000 BTU N/A SEE SELECTIONS TILE DAM WALL N/A N/A N/A PROPERTY LINE EXISTING 6'-0" HIGH BLOCK WALL UNDER WATER POOL LIGHT UNDER WATER SPA LIGHT SAFETY EXIT DOOR ALARM MAIN HOUSE 200 AMP ELECTRICAL PANEL EXISTING GAS METER PLAN APPROVED BY: SALESPERSON:BLAKLEY GUNITE DAM WALL TO FINISH AT 103 4" SPA AT -0- WITH TILE DAM WALL TANNING SHELF AT 12" WATER DEPTH WITH ONE UMBRELLA SLEEVE BROOM FINISH CONCRETE DECKING SAFETY EXIT DOOR ALARM PROPERTY LINE EXISTING 6'-0" HIGH BLOCK WALL PROPERTY LINE EXISTING 6'-0" HIGH BLOCK WALL PROPERTY LINE