Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Plans
Pr o j e c t N a m e Date Drawn: Drawn By: Revision No. Sheet No. 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 SHEET INDEX GENERAL C1 COVER SHEET S1 SITE PLAN S2 PLOT PLAN ELECTRICAL E1 PROJECT SIGNAGE E2 SINGLE LINE STRUCTURAL P1 PROFILE ELEVATIONS DATA SHEET MODULE LOAD CALCULATION WIND CALCULATION RACKING LOAD CENTER C1 COVER SHEET VICINITY MAP Riverside County: APN 622340029 0 APPLICABLE CODES: California Residential Code 2019 California Electrical Code 2019 National Electrical Code 2017 2019 California Amendments City of Palm Desert Municipal Code JACK GERONIMO 09/22/2022 CA R O L Y N G O T T L I E B PA L M D E S E R T , C A . 9 2 2 6 0 BR U C E G O T T L I E B ( C S H 4 5 8 4 3 A D D - O N ) 40 8 7 5 A V E R O S A R I O SCOPE OF WORK: Project consists of installing a solar photovoltaic (PV) system comprised of: PV modules, power inverter(s), conduits w/fittings and wires, roof stanchions, and a rack mounting system to provide a renewable power source for the customer. PROJECT CONTACTS: CONTRACTOR: RENOVA permits@renovaenergy.com Primary Contact: Matthew De La Torre Secondary Contact: Amy Dominguez CONSTRUCTION HOURS: OCTOBER 1 THRU APRIL 30 Monday - Friday 7:00 am - 5:30 pm Saturday 8:00 am - 5:00 pm Sunday NOT ALLOWED Government Code Holidays NOT ALLOWED MAY 1 THRU SEPTEMBER 30 Monday - Friday 6:00 am - 7:00 pm Saturday 8:00 am - 5:00 pm Sunday NOT ALLOWED Government Code Holidays NOT ALLOWED ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA RESIDENTIAL CODE, 2019 ELECTRICAL CODE BASED ON THE 2017 NATIONAL ELECTRICAL CODE. NOTES: 1. THIS IS A 9.960 KW SOLAR ELECTRIC SYSTEM USING (24) SUNPOWER SPR-M415-BLK-H-AC MODULES (415 WATT). 2. THIS SYSTEM IS GRID-INTERTIED VIA AC MODULES PER NEC 690.6. 3. THIS SYSTEM HAS NO UPS, NO BATTERIES. 4. THIS IS A ROOF MOUNTED SYSTEM, ADDING 2.84 LB/SQ FT. ROOF IS SPANISH CONCRETE TILE AT 17° PITCH. 5. THE SYSTEMS SQUARE FOOTAGE IS 499 FT² (23% OF TOTAL ROOF AREA). MODULES HAVE AN AZIMUTH OF 180°. 6. MODULES ARE 0° TILT ABOVE ROOF SLOPE, NOT TO EXCEED 18" ABOVE ROOF SURFACE. 7. BUILDING IS A SINGLE STORY DWELLING. 8. LAG SCREWS ARE 5/16" X 4" AT 72" O.C. MAX, WITH 2.5" INTO FRAMING. 9. CONCRETE TILE TO BE REMOVED AND INSTALL COMPOSITE SHINGLE WHERE MODULES WILL BE LOCATED. MODULES WILL BE SECURED TO ROOFTOP USING PEGASUS COMP MOUNT ATTACHMENTS WITH INVISIMOUNT SUPPORT RAILS. 10. ATTACHMENTS WILL BE FLASHED. 11. DESIGNED FOR BASIC WIND SPEED OF 130 MPH (WIND EXPOSURE C) PER INVISIMOUNT CALCULATIONS, SEE SPECS. 12. VISIBLE EXPOSED CONDUIT SHALL BE PAINTED TO MATCH. 13. MODULE DIMENSIONS ARE 40.6" X 73.7" 14. SYSTEM INSTALLATION SHALL BE PER NEC 690 AND IS SUBJECT TO FIELD INSPECTION BY THE CITY. 15. PROPER CLEARANCES SHALL BE IN ACCORDANCE WITH CAL FIRE GUIDELINES. 16. EXISTING (36) NE-170U1 PV MODULES TO BE REMOVED. SOLAR SYSTEM SIZE: 9.960 kW DC CEC AC SYSTEM SIZE: 9.091 kW AC - CIRCUIT #1 - CIRCUIT #2 EXISTING METER #222012-540304 EXISTING 200 AMP MAIN SERVICE PANEL 120/240 VOLT, 1Φ, 3W LOCATED ON SOUTH EXTERIOR WALL - CIRCUIT #3 VENT AV E R O S A R I O EXISITNG PV SYSTEM TO BE REMOVED EXISTING 5.2kw INVERTER #PVP5200 LOCATED INSIDE GARAGE 1. 5 ' 1. 5 ' 1. 5 ' 1. 5 ' 1. 5 ' 1. 5 ' 3' BA C K Y A R D PR O P E R T Y L I N E SIDE YARD PROPERTY LINE PROPERTY LINE SIDE YARD DRIVEWAY CHIMNEY CHIMNEY - EXISTING PV ARRAY AC SOLAR MODULES 125 AMP AC LOAD CENTER EATON #BR816L125RP 120/240 VOLT LOCATED INSIDE GARAGE 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Sheet No. Revision No. Date Drawn: Drawn By: Pr o j e c t N a m e : Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 0 S1 SITE PLAN JACK GERONIMO 09/22/2022 CA R O L Y N G O T T L I E B PA L M D E S E R T , C A . 9 2 2 6 0 BR U C E G O T T L I E B ( C S H 4 5 8 4 3 A D D - O N ) 40 8 7 5 A V E R O S A R I O NOTE: RED BACKGROUND WITH WHITE LETTERING 3/8" LETTER HEIGHT PROJECT SIGNAGE NOTES & PANEL SCHEDULE AC LOAD CENTER WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. MAX AC OPERATING CURRENT: 38.4 A OPERATING AC VOLTAGE: 240 Volts SOLAR BREAKER WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE. MAIN PANEL THIS PANEL IS FED BY TWO SOURCES: UTILITY AND SOLAR PHOTOVOLTAIC MAIN PANEL: MECHANICALLY ATTACHED WARNING THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. SOLAR BREAKER RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LOAD CENTER PHOTOVOLTAIC DISCONNECT BREAKER LOCATED INSIDE VA LOAD CIRCUIT 1 A B L 20 TYPE C.B. BUS CO D E N R L TR P x x CONNECTED VA (CODE L):9216 9.22 38.4 A B - 4608 4608 CIRCUIT 1 PHASE TOTAL LOAD DESCRIPTION L 20 - 2 - VA LOAD AB L TYPEC.B. CO D E NRLTRP LOAD DESCRIPTION L PANEL: LOAD CENTER LOCATION: GARAGE MOUNTING: SURFACE PANEL VOLTAGE: 240/120 V 1Φ,3W BUS: 125A N: NON-CONTINUOUS L: LONG-CONTINUOUS R: DEMANDABLE RECEPTACLES CIRCUIT CODE: CONNECTED VA (CODE R): CONNECTED VA (CODE N): TOTAL CONNECTED KVA: TOTAL PANEL AMPS: PHASE TOTALS A+B MAIN PANEL (YOU ARE HERE) CIRCUIT 2 L 20 x x-CIRCUIT 2 L 20 - 2 - L L RAPID SHUTDOWN (CB INSIDE MAIN) MAIN BREAKER THE MAIN BREAKER HAS BEEN DOWN-SIZED TO 150 AMPS NO UP-SIZING IS PERMITTED MARKING 1. THE MATERIAL USED FOR MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. MARKING AS REQUIRED IN SECTIONS R 331.2.2 THROUGH R331.2.4 SHALL HAVE LETTERS CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8" WHITE ON RED BACKGROUND. (CRC R331.2.1) 2. THE MARKING CONTENT SHALL CONTAIN THE WORDS "WARNING; PHOTOVOLTAIC POWER SOURCE" (CRC R331.2.2) SAFEGUARDS 1. SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL. ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE-D & GE. 2. ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED. 3. WILEY CABLE CLIPS SHALL BE USED. 4. ALL EMT SHALL USE OUTDOOR RAINTIGHT COMPRESSION FITTINGS. 5. ALL EQUIPMENT SHALL BE LABELED. 6. ADD COMBINER / JUNCTION BOXES AS NEEDED. 7. AN INTERNAL BLOCKING DIODE IS PROVIDED IN EACH MODULE. 8. MODULE GROUNDING SHALL BE MADE VIA RACKING CLAMPS. 9. ALL NEUTRAL TO GROUND CONNECTIONS SHALL OCCUR IN THE MAIN PANEL. 10. EMT SHALL BE 3/4" MINIMUM. 11. JUNCTION BOX/ COMBINER BOX ENTRY SHALL USE COMPRESSION FITTINGS. NOTES 1. WIRE AND SIZES ARE AS INDICATED OR LARGER. 2. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. 3. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. 4. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. ALL WIRING BETWEEN AC MODULES SHALL BE PV-WIRE AND AC CABLE. ALL CONDUIT SHALL BE 3/4" EMT OR LARGER. ALL CONDUIT SHALL BE BONDED. ALL CONDUIT SHALL BE SUPPORTED BY RUBBER PYRAMID SUPPORTS. STEEL CITY 6"X6"X4" (OR LARGER) OUTDOOR JUNCTION BOXES SHALL BE USED AS NEEDED. ALL CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF CONNECTORS TO PROTECT WIRES. MAIN PANEL PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS 1536 1536 1920 1920 CIRCUIT 3 L 20 x x-CIRCUIT 3 L 20 - 2 - L L 1152 1152 5.2 kW INVERTER (INSIDE GARAGE) EXISTING AC DISCONNECT SYSTEM NOT EQUIPPED WITH RAPID SHUT DOWN 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Sheet No. Revision No. Date Drawn: Drawn By: Pr o j e c t N a m e : Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 E1 PROJECT SIGNAGE 0 JACK GERONIMO 09/22/2022 CA R O L Y N G O T T L I E B PA L M D E S E R T , C A . 9 2 2 6 0 BR U C E G O T T L I E B ( C S H 4 5 8 4 3 A D D - O N ) 40 8 7 5 A V E R O S A R I O CONDUIT SCHEDULE LOCATION CONDUCTORS CONDUIT 1 (6) #10 THWN-2, (1) #10 EGC 3/4" EMT 2 (3) #6 THWN-2, (1) #10 EGC 3/4" EMT 3 (3) #12 THWN-2, (1) #12 EGC 3/4" EMT G BAR DOWNSIZE EXISTING 200A MAIN BREAKER TO 150A 50 AMP SOLAR BREAKER EXISTING GROUNDING ELECTRODE TO UTILITY METER #222012-540304M SINGLE LINE DIAGRAM CALCULATIONS SOLAR SYSTEM SIZE: 9.960 kW DC CEC AC SYSTEM SIZE: 9.091 kW AC N BAR AC CIRCUITS AC MODULES TO AC LOAD CENTER 1 CIRCUIT X 10 MODULES, 1 CIRCUIT X 8 MODULES, & 1 CIRCUIT X 6 MODULES = 24 MODULES MAX VOLTAGE AC 240 VOLT 1.60 AMPS EACH CIRCUIT X MAX 10 MODULES X 1.25[PER NEC 690.8] = 20.0 AMPS (20 AMP CB) AC CONDUIT SHALL BE MOUNTED A MINIMUM OF 1" ABOVE ROOFTOP SURFACE. ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 42°C AMBIENT TEMP. PER SOLARABCS.ORG #10 WIRE = 40 AMPS X .82[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(A)] = 32.8 AMPS 32.8 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(3)(a)] = 26.24 AMPS > 20 AMPS ✓ 3 CIRCUITS = (6) #10 THWN-2 AWG WIRE, (1) #10 THWN-2 GROUND 3/4" EMT @ 40% FILL PER NEC TABLE C.1 = (10) #10 THWN-2 WIRES ✓ AC LOAD CENTER TO MAIN PANEL MAX OUTPUT = 24 MODS X 1.60 AMP X 1.25 [PER NEC 215.2 (A)1] = 48.0 AMPS (50 AMP SOLAR BREAKER) AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE. ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 42°C AMBIENT TEMP. PER SOLARABCS.ORG #6 WIRE = 75 AMPS X .82[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(A)] = 61.5 AMP > 50 AMP ✓ (3) #6 THWN-2 AWG WIRE, (1) #10 THWN-2 GROUND 3/4" EMT @ 40% FILL PER NEC TABLE C.1 = (4) #6 THWN-2 WIRES ✓ MAIN PANEL BACKFEED CALCULATION EXISTING 200 AMP MAIN SERVICE PANEL DOWNSIZE EXISTING 200 AMP MAIN BREAKER TO 150 AMP 120% OF 200 AMP BUS: ALLOWABLE BACKFED AMPS [PER NEC 705.12(B)(2)] = 240 AMPS 240 AMP - 150 AMP MAIN BREAKER = 90 TOTAL AMP ALLOWABLE MAX OUTPUT = (24 MODS X 1.60 AMP + 25 AMP INVERTER) X 1.25 [PER NEC 215.2 (A)1] = 79.3 AMPS MAX OUTPUT = 79.3 AMPS ≤ 90 AMPS ✓ EXISTING 200 AMP MAIN SERVICE PANEL 240/120 VOLT, 2-POLE LOCATED ON SOUTH EXTERIOR WALL SERVICE EQUIPMENT IS CENTER FED *FOR UTILITY PURPOSES ONLY:(24) ENPHASE IQ7HS-66-ACM-US (IQ7HS-66-ACM-US) 240V [SI1] INVERTERS (18) SHARP NE-17U1 EGC = EQUIPMENT GROUNDING CONDUCTOR, GEC = GROUNDING ELECTRODE CONDUCTOR #6 COPPER SOLID GROUND TO BE USED ON ROOFTOP WHEN NOT PROTECTED BY CONDUIT ALL BREAKERS SHALL BE 2 POLE UNLESS OTHERWISE NOTED ALL INNER-CIRCUIT WIRING SHALL BE #10 THWN-2 WIRE OR GREATER. SOLAR BREAKER SUITABLE FOR DISCONNECTING MEANS PER NEC 690.13 SOLAR ARRAY (24) SUNPOWER 415 WATT PHOTOVOLTAIC MODULES #SPR-M415-BLK-H-AC (1 CIRCUIT OF 10 MODULES, 1 CIRCUIT OF 8 MODUELS, & 1 CIRCUIT OF 6 MODULES) PVS6 (MONITOR) INTERNET, 240V LOCATED NEXT TO LOAD CENTER 20A 20A BREAKER 1 OF 3 BREAKER 2 OF 3 N BAR G BAR 3 2 15A 20A BREAKER 3 OF 3 125 AMP AC LOAD CENTER EATON #BR816L125RP 240V, 2P LOCATED INSIDE GARAGE1 DC DISCO. EXISTING 5.2KW INVERTER PV POWERED PVP5200 120/240 VOLT LOCATED INSIDE GARAGE EXIST. SOLAR ARRAY (18) SHARP 170 WATT PHOTOVOLTAIC MODULES #NE-170U1 30 AMP BREAKER 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Sheet No. Revision No. Date Drawn: Drawn By: Pr o j e c t N a m e : Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 0 E2 SINGLE LINE 0 JACK GERONIMO 09/22/2022 CA R O L Y N G O T T L I E B PA L M D E S E R T , C A . 9 2 2 6 0 BR U C E G O T T L I E B ( C S H 4 5 8 4 3 A D D - O N ) 40 8 7 5 A V E R O S A R I O 1 7 ° 1 0 ' ' A A' 6' 4' 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Sheet No. Revision No. Date Drawn: Drawn By: Pr o j e c t N a m e : Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 SCALE: 1"=4'2 SCALE:11"=12' TOP VIEW ELEVATION A-A' SCALE: 1"=5'3 *MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE *MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE SCALE: N/A 4 *MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE*MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE ATTACHMENT DETAIL ELEVATION B-B' P1 PROFILE ELEVATIONS HORIZONTAL DISTANCE BETWEEN ATTACHMENTS NOT TO EXCEED 6 FEET ON CENTER VERTICAL DISTANCE BETWEEN ATTACHMENTS NOT TO EXCEED 4 FEET ON CENTER - USE (1) 5/16" x 4" SS LAG SCREWS AT 6' O.C. WITH 2.5" EMBEDMENT INTO WOOD RAFTERS. - RAFTERS ARE 2"x6" AT 2' O.C. - DO NOT INSTALL STANDOFFS OVER WOOD CRICKETS - STANDOFFS ATTACHED TO MAIN ROOF FRAMING. 0 JACK GERONIMO 09/22/2022 CA R O L Y N G O T T L I E B PA L M D E S E R T , C A . 9 2 2 6 0 BR U C E G O T T L I E B ( C S H 4 5 8 4 3 A D D - O N ) 40 8 7 5 A V E R O S A R I O RAFTER Pr o j e c t N a m e Date Drawn: Drawn By: Revision No. Sheet No. 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 S2 PLOT PLAN 0 JACK GERONIMO 09/22/2022 CA R O L Y N G O T T L I E B PA L M D E S E R T , C A . 9 2 2 6 0 BR U C E G O T T L I E B ( C S H 4 5 8 4 3 A D D - O N ) 40 8 7 5 A V E R O S A R I O 425-410 W Residential Black AC Module SunPower® Maxeon® Technology Built specifically for use with the SunPower Equinox® system, the only fully integrated solution designed, engineered, and warranted by one company. Highest Power Density Available The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest-efficiency all-black AC solar module available.1 Highest Lifetime Energy and Savings Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.2 Best Reliability, Best Warranty With more than 42.6 million and 15 GW of modules deployed around the world, SunPower technology is proven to last. That’s why we stand behind our module and microinverter with the industry’s best 25-year Combined Power and Product Warranty, including the highest Power Warranty in solar. Datasheet 0510 15 20 25 150% 140% 130% 120% 110% 100% 90% 80% 70% 60%25 - y e a r E n e r g y Y i e l d p e r W a t t Years of Operation Up to 60% More Lifetime Energy Conventional Panel M-Series Part of the SunPower Equinox® Solar System • Seamless aesthetics • Compatible with mySunPower monitoring Factory-integrated Microinverter • Highest-power integrated AC module in solar • Engineered and calibrated by SunPower for SunPower AC modules 6. 3 7 i n [1 6 1 . 7 m m ] 6. 5 4 i n [1 6 6 m m ] 5% larger need blk image 1 Based on datasheet review of websites of top 20 manufacturers per IHS, as of July 2021. 2 Maxeon 435 W, 22.5% efficient, compared to a Conventional Panel on same-sized arrays (300 W, 19% efficient, approx. 1.6 m²), 7.9% more energy per watt (based on PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al. “Robust PV Degradation Methodology and Application.”PVSC 2018). 3 Based on search of datasheet values from websites of top 10 manufacturers per IHS, as of June 2021. 4 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 5 Factory set to IEEE 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. 6 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25°C). All DC voltage is fully contained within the module. 7 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer’s instructions. 8 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. See www.sunpower.com/company for more reference information. For more details, see extended datasheet: www.sunpower.com/solar-resources. Specifications included in this datasheet are subject to change without notice. ©2022 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo and EQUINOX are registered trademarks of SunPower Corporation in the U.S. MAXEON is a registered trademark of Maxeon Solar Technologies, Ltd. For more information visit www.maxeon.com/legal. AC Electrical Data Inverter Model: Type H (Enphase IQ7HS)@240 VAC @208 VAC Max. Continuous Output Power (VA)384 369 Nom. (L–L) Voltage/Range3 (V)240 / 211–264 208 / 183–229 Max. Continuous Output Current (A)1.60 1.77 Max. Units per 20 A (L–L) Branch Circuit4 10 9 CEC Weighted Efficiency 97.0%96.5% Nom. Frequency 60 Hz 60 Hz Extended Frequency Range 47–68 Hz 47–68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A 4.82 A Overvoltage Class AC Port III III AC Port Backfeed Current 18 mA 18 mA Power Factor Setting 1.0 1.0 Power Factor (adjustable)0.85 (inductive) / 0.85 (capacitive)0.85 (inductive) / 0.85 (capacitive) DC Power Data SPR-M425-BLK-H-AC SPR-M415-BLK-H-AC SPR-M410-BLK-H-AC Nom. Power⁶ (Pnom) W 425 415 410 Power Tolerance +5/−0%+5/−0%+5/−0% Module Efficiency 22.0%21.5%21.2% Temp. Coef. (Power)−0.29% / °C −0.29% / °C −0.29% / °C Shade Tolerance Integrated module-level max. power point tracking Tested Operating Conditions Operating Temp.−40° F to +185° F (−40° C to +85° C) Max. Ambient Temp.122° F (50° C) Max. Test Load⁸Wind: 125 psf, 6000 Pa, 611 kg/m² back Snow: 187 psf, 9000 Pa, 917 kg/m² front Max. Design Load Wind: 75 psf, 3600 Pa, 367 kg/m² back Snow: 125 psf, 5400 Pa, 550 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 66 Maxeon Gen 6 Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 48 lbs (21.8 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) Warranties, Certifications, and Compliance Warranties • 25-year limited power warranty • 25-year limited product warranty Certifications and Compliance • UL 1741 / IEEE-1547 • UL 1741 AC Module • UL 61730 (Type 2 fire rated) • UL 62109-1 / IEC 62109-2 • FCC Part 15 Class B • ICES-0003 Class B • CAN/CSA-C22.2 NO. 107.1-01 • CA Rule 21 (UL 1741 SA)⁵ (includes Volt/Var and Reactive Power Priority) • UL Listed PV Rapid Shutdown Equipment⁷ Enables installation in accordance with: • NEC 690.6 (AC module) • NEC 690.12 Rapid Shutdown (inside and outside the array) • NEC 690.15 AC Connectors, 690.33(A)–(E)(1) When used with AC module Q Cables and accessories (UL 6703 and UL 2238)⁷ • Rated for load break disconnect PID Test 1000 V: IEC 62804 Packaging Configuration Modules per pallet 25 Packaging box dimensions 75.4 × 42.2 × 48.0 in. (1915 × 1072 × 1220 mm) Pallet gross weight 1300 lb (590 kg) Pallets per container 32 Net weight per container 18,880 kg M425-BLK | M415-BLK | M410-BLK SunPower Residential Black AC Module 1-800-SUNPOWER | sunpower.com 544400 RevA January 2022 Please read the safety and installation instructions for details. Customer Name: 1. a. 2,757 sq.ft. x 3 VA =8,271 VA b.Small appliance loads; 1,500 VA x 2 circuits =3,000 VA c.1,920 VA d. =1,200 VA =1,176 VA =1,440 VA =0 VA =7,680 VA =0 VA =0 VA =6,986 VA =1,440 VA =0 VA =0 VA (Subtotal)33,113 VA First 10,000VA x 100% =10,000 VA Remaining 23,113 VA x 40%9,245 VA 19,245 VA 2. Heating units (3 or less) =VA x 65%0 VA Heating units (4 or more) =VA x 40%VA 7,005 VA x 100%7,005 VA 6,982 VA x 100%6,982 VA 13,987 VA 33,232 VA SERVICE: SERVICE:I = 33,232 VA =138.5 A 240 V Service amperes required 138.5 A Service amperes provided 200 A 9/20/2022 RJ HEATING OR A/C LOAD: Disposal Refrigerator Water heater ( if Gas =0) Oven- 220.55 (Total #1 = Net Load) Microwave Dishwasher Cook Top Pool Garage/outside plugs Clothes Dryer General lighting & receptacle loads; EV car charger - future SINGLE-FAMILY DWELLING - LOAD CALCULATION NEC 2017 Edition: Following Example Annex D2(b) Bruce Gottlieb; 40875 Ave Rosario, Palm Desert, CA 92260 Special loads: OTHER LOADS: Laundry = (Total #2 = Net Load) A/C unit # 12789 = A/C unit # 07755 = Net Load (Total #1 + Total #2 = Subtotal Net Load)I = 𝑉𝑉𝑉𝑉𝑉𝑉 Document #524734 Rev D, Vol. 2 1 SunPower Proprietary InvisiMount Span Tables Engineering Summary Letter Volume: 2 ASCE 7 Version: 7-16 Module Type: E/X Series (96-cell) Roof Attachment: Pegasus Tile Roof - Generation 1 The following tables list the allowable spacing of attachment points for the SunPower InvisiMount mounting system. The following building codes and standards were used in the calculations: • California Building Code (CBC 2019) • California Residential Code (CRC 2019) • Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) List of Volumes: 1. E/X Series Module + Pegasus Composite Shingle Attachment 2. E/X Series Module + Pegasus Gen1 Tile Attachment 3. E/X Series Module + Pegasus Gen2 Tile Attachment 4. A Series Module + Pegasus Composite Shingle Attachment 5. A Series Module + Pegasus Gen1 Tile Attachment 6. A Series Module + Pegasus Gen2 Tile Attachment Loads on the system were calculated in accordance with ASCE 7-16, using the following parameters: • Risk Category II • System weight (including PV modules and rails) = 2.50 psf • Module orientations: Portrait & Landscape • No live load acts on top of the PV modules • Wind speed & exposure as indicated in the tables • Roof height and slope as indicated in the tables • Gable and Hip roofs only with modules not in the overhang sections of the roof • For wind load, topographic factor Kzt = 1.0, and directionality factor Kd = 0.85 per ASCE 7-16 Table 26.6-1 • Wind load coefficients per either wind tunnel testing or ASCE 7-16 Chapter 30 (see notes below tables) • Ground snow load as indicated in the tables • For snow loads, thermal factor Ct = 1.2 (“unheated and open air structures”), per ASCE 7-16 Table 7.3-2 • For snow loads, exposure factor Ce = 0.9 (“fully exposed”), per ASCE 7-16 Table 7.3-1 • For snow loads, slope factor Cs is determined per ASCE 7-16 Figure 7-2 assuming the array is an “unobstructed slippery surface” where snow is free to slide off the array • Seismic short-term spectral acceleration (Ss) = 3.73g, maximum, and seismic site class = D, per ASCE 7-16 Section 11.4.2 • Seismic component importance factor Ip = 1.0 per ASCE 7-16 Section 13.1.3; seismic component response factor Rp = 1.5, and component amplification factor ap = 1.0, per ASCE 7-16 Table 13.5-1 and 13.6-1; seismic loads are calculated per ASCE 7-16 Chapters 11 and 13 • Load combinations per CBC Section 1605.2 Document #524734 Rev D, Vol. 2 2 SunPower Proprietary The maximum allowable spans shown in the tables are based on the calculated loads and the capacity of the rail and the attachment, determined by analysis and testing in accordance with CBC 2019 and referenced standards. • Bending strength of aluminum rails is calculated according to the Aluminum Design Manual 2015 Section B.3.2.1 (LRFD) • The strength of the roof attachment hardware is based on product information from the attachment manufacturer • The strength of the lag screw in withdrawal and shear is calculated according to the National Design Specification (NDS) for Wood Construction, 2018 • The maximum allowable attachment spacing is calculated by checking the demand/capacity ratios for bending in the rail and tension, compression and shear on attachments for all required load combinations. The reported maximum allowable spacing is the greatest spacing, rounded down to the nearest rafter spacing increment, for which the demand/capacity ratios are less than or equal to 1.0. • These tables do not consider the strength of the supporting roof structure. In areas of low snow load, the weight of the array is often considered to offset the design live load of the roof, since personnel and equipment cannot be placed on top of the array. It is recommended to stagger attachment points, as shown in Figure 1, to evenly distribute loads to the rafters. Figure 1 • These tables assume that each module is installed centered over a pair of rails, as shown in Figure 2(a). In cases where one rail is closer to the midpoint of the module, as shown in Figure 2(b), adjustments to the spacing may be required. Figure 2 'HVLJQ1DPH 1DPH 6XUQDPH2ZHQ .HQQHWK .HQQHWK0LFKDHO 7RUFKOLJKW/DQH3DOP6SULQJV&DOLIRUQLD8QLWHG6WDWHV)XOO$GGUHVV 7RWDO1XPEHURI3DQHOV 7RWDO1XPEHU2I$WWDFKPHQWV 7RWDO1XPEHURI5DLOV 7RWDO1XPEHURI6SOLFHV 7RWDO1XPEHURI0LG&ODPSV 7RWDO1XPEHURI(QG&ODPSV 7RWDO1XPEHURI:LUH&OLSV 7RWDO1XPEHURI5DLO*URXQGLQJ.LWV 5RRI 5RRI6ORSH *URXQG6QRZ/RDGpg IW $WWDFKPHQW7\SH 7RSRJUDSKLF)DFWRUKzt 4XLFN+RRN.LW´EDVHFXUYHGDQGIODWWLOH4XLFN0RXQW 40+66 3DQHO2ULHQWDWLRQ PSK & 5DIWHU6SDFLQJ 3DQHO0RGHO 8VHULQSXW 5DLO'LUHFWLRQ 3DUDOOHOWRULGJH IW J 0HDQ5RRI+HLJKWh %XLOGLQJ/HDVW+RUL]RQWDO'LPHQVLRQwidthbldg 3RUWUDLW %DVLF:LQG6SHHGV FHOO LQ SVI 6HLVPLF3DUDPHWHUSs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pg IW $WWDFKPHQW7\SH 7RSRJUDSKLF)DFWRUKzt 4XLFN+RRN.LW´EDVHFXUYHGDQGIODWWLOH4XLFN0RXQW 40+66 3DQHO2ULHQWDWLRQ PSK & 5DIWHU6SDFLQJ 3DQHO0RGHO 8VHULQSXW 5DLO'LUHFWLRQ 3DUDOOHOWRULGJH IW J 0HDQ5RRI+HLJKWh %XLOGLQJ/HDVW+RUL]RQWDO'LPHQVLRQwidthbldg 3RUWUDLW %DVLF:LQG6SHHGV FHOO LQ SVI 6HLVPLF3DUDPHWHUSs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unPower® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates even module spacing • Simple, pre-drilled rail splice • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs • Design in landscape and portrait • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics ȏ 3UHPLXPORZSURȴOHGHVLJQ • Black anodized components • Hidden mid clamps and end clamps KDUGZDUHDQGFDSSHGȵXVKUDLOV Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Combine with SunPower modules and monitoring app sunpower.com Elegant Simplicity SunPower® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster LQVWDOODWLRQWLPHGHVLJQȵH[LELOLW\DQGVXSHULRUDHVWKHWLFV 7KHΖQYLVL0RXQWSURGXFWZDVVSHFLȴFDOO\HQYLVLRQHGDQG engineered to pair with SunPower modules. The resulting system-level approach will amplify the aesthetic and LQVWDOODWLRQEHQHȴWVIRUERWKKRPHRZQHUVDQGLQVWDOOHUV SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug)106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Roof Attachment Hardware Supported by InvisiMount System Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal Interface for Other Roof Attachments InvisiMount Operating Conditions Temperature ȫr&WRr&ȫr)WRr) Max. Load 2400 Pa uplift 5400 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation ΖQYLVL0RXQW:DUUDQWLHV$QG&HUWLȴFDWLRQV Warranties 25-year product warranty \HDUȴQLVKZDUUDQW\ &HUWLȴFDWLRQV UL 2703 Listed &ODVV$ȴUHUDWLQJZKHQGLVWDQFHEHWZHHQ roof surface and bottom of SunPower PRGXOHIUDPHLVȱȋ *Module frame that is compatible with the InvisiMount system required for hardware interoperability. © 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. 6SHFLȴFDWLRQVLQFOXGHGLQWKLVGDWDVKHHWDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH InvisiMount Component Images Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap Module* / End Clamp and Rail sunpower.com Document #509506 Rev B WATERTIGHT FOR LIFE Pegasus Solar’s Comp Mount is a cost effective, high-quality option for rail installations on composition shingle roofs. Designed to last decades, the one-piece flashing with elevated cone means there is simply nothing to fail. A BETTER DAY ON THE JOB COMP MOUNT 25-year Warranty Manufactured with advanced materials and coatings to outlast the roof itself Superior Waterproofing Tested to AC286 without sealant 0.9” elevated water seal Code Compliant Fully IBC/CBC Code Compliant Exceeds ASCE 7-10 Standards All-In-One Kit Packaging Flashings, L-feet and SS lags with bonded EPDM washers are included in each 24-pack Simple 3-piece design for rapid installation One-piece flashing with elevated cone – No press-fits or deck-level EPDM washers to fail Encapsulating design raises the water seal 0.9” above roof deck Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804 T: 510.730.1343 www.pegasussolar.com 1. Drill pilot hole in center of rafter. 3. Place L-Foot over cone and install lag with washer through L-Foot. 2. Optional: Apply a “U-shape” of sealant to underside of flashing and position under 2nd shingle course, cone over pilot hole. 4. Drive lag to required embedment. Attach rail per rail manufacturer’s instructions. COMP MOUNT Patents Pending. All rights reserved. © 2018 Pegasus Solar Inc. Specifications Comp Mount Install Kit L-Foot, Flashing, 5/16” SS Lag w/ EPDM washer L-Foot, Flashing, 5/16” SS Lag w/ EPDM washer L-Foot, Flashing, 5/16” SS Lag w/ EPDM washer, M10 Hex Bolt 2.3" 3.5"1.5" 2.3" 3.5" 1.9" 2.4" 0.9" 9.0" 11.6" Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804 T: 510.730.1343 www.pegasussolar.com SKU PSCR-C0 PSCR-U0 SPCR-CH L-foot Type Closed Slot Open Slot Closed Slot Kit Contents Finish Black (L-foot and Flashing) Roof Type Composition Shingle Certifications IBC, ASCE/SEI 7-10, AC286 Install Application Railed Systems Compatible Rail All Flashing Material Painted Galvalume Plus L-Foot Material Aluminum Kit Quantity 24 Boxes Per Pallet 72 $&&$FPH&DEOH&OLSV &RQWDFWXVDWZZZZHOOFFRP 0DGHZLWKFRUURVLRQUHVLVWDQWVHULHVVWDLQOHVVVWHHO 'XDOZLUHFRPSDUWPHQWV 6SHFLDOWDEIRUHDV\LQVWDOODWLRQDQGUHPRYDOZLWKÀDWKHDGVFUHZGULYHU 'HVLJQHGWRSUHYHQWGDPDJHWRFDEOHLQVXODWLRQ 6L]HGIRU86(FDEOHPPRU39FDEOHPP $&& +ROGVWR86(ZLUHV RU39ZLUH $&&39 +ROGVWR39ZLUHV $&0(&DEOH&OLSVVLPSOLI\ZLUHPDQDJHPHQWDQGFUHDWHDFOHDQHUDHVWKHWLFWRVRODU39DUUD\V7KH FOLSVDUHPDGHRIFRUURVLRQUHVLVWDQWVWDLQOHVVVWHHODQGDUHGHVLJQHGWRSUHYHQWGDPDJHWRFDEOHLQVX ODWLRQ7KHHDV\WRLQVWDOODQGUHPRYHGHVLJQRQO\UHTXLUHVDÀDWKHDGVFUHZGULYHUDQGFDQEHUHXVHG XQOLNH]LSWLHV7KHXQLYHUVDOGHVLJQ¿WVPRVWPRGXOHVDQGFDQKROGRQHRUWZRZLUHV 0DGHRIFRUURVLRQUHVLVWDQWWLQSODWHFRSSHU 'HVLJQHQVXUHVIRUHDV\LQVWDOODWLRQ $YDLODEOH :LWK:((% ®ZDVKHUWHFKQRORJ\ $VVHPEOHGDQGXQDVVHPEOHG :LWKRUZLWKRXWLQVWDOODWLRQKDUGZDUH /RZSUR¿OHGHVLJQ 1RVXUIDFHSUHSHUDWLRQRQUDLORUPRGXOHUHTXLUHG 5HOLDELOLW\WKURXJKRXWWKHOLIHWLPHRIWKH39V\VWHP 0XOWLSOHHTXLSPHQWJURXQGFRQGXFWRUDOORZDQFH 2QH$:*WR$:*RUWZR$:*WZR$:* /LVWHGWR$16,8/E\,QWHUWHN(7/ &6$&HUWL¿HGWR&1R &XVWRPGHVLJQVDYDLODEOHXSRQUHTXHVW :((%®/8* 7KH:((%®/XJFRQVLVWVRID:((%®ZDVKHUOD\LQOXJDQGKDUGZDUH,WLVXVHGZLWKRQHVROLGRUVWUDQGHG FRSSHUZLUH$:*WR$:*RUWZRFRSSHUZLUHV$:*WR$:*WRSURYLGHDFRQWLQXRXVJURXQGRQURRI RUJURXQGPRXQWHGVRODUV\VWHPV8QOLNHWUDGLWLRQDOOD\LQOXJVWKH:((%®/XJGRHVQRWUHTXLUHVXUIDFH SUHSDUDWLRQRQUDLORUPRGXOHWRLQVWDOO7KH:((%®/XJLVLQVWDOOHGXVLQJVWDLQOHVVVWHHOPRXQWLQJKDUGZDUH :KHQWKHKDUGZDUHLVWLJKWHQHGWKH:((%®ZDVKHUV¶VSHFLDOL]HGWHHWKHPEHGLQWRDQRGL]HGDOXPLQXPJDOYDQL]HG VWHHORUDQ\HOHFWULFDOO\FRQGXFWLYHPHWDOWRHVWDEOLVKDJDVWLJKWHOHFWULFDOFRQQHFWLRQ7KHWLQSODWHG/XJDVVXUHV PLQLPXPFRQWDFWUHVLVWDQFHDQGSURWHFWLRQDJDLQVWFRUURVLRQ&RSSHUZLUHLVFODPSHGE\DVWDLQOHVVVWHHO VFUHZZKLFKLVKRUL]RQWDOWRWKHWDQJIRUHDV\DFFHVVZKHQPRXQWHGXQGHUD39PRGXOH7KHORZSUR¿OHRIWKH :((%®/XJDOORZVLWWREHLQVWDOOHGLQDYDULHW\RISRVLWLRQV Catalog Item # L x W x H Hole Hardware Torque :((%/8* ´[´[´ ´ LQFKKDUGZDUH LQFOXGHGXQDVVHPEOHG IWOEVIRU WHUPLQDOVFUHZ IWOEVIRU PRXQWLQJ KDUGZDUH Z3HQHWUR[$ RQWKUHDGV :((%/8*$6 ´[´[´ LQFKKDUGZDUH LQFOXGHGDVVHPEOHG :((%/8* ´[´[´ ´ 0RULQFKKDUGZDUH QRWLQFOXGHG :((%/8*$6 ´[´[´ LQFKKDUGZDUH LQFOXGHGDVVHPEOHG :((%/8*81 ´[´[´ LQFKKDUGZDUH LQFOXGHGXQDVVHPEOHG :((%/8* ´[´[´ 0RULQFKKDUGZDUH QRWLQFOXGHG &XVWRPHU6HUYLFH'HSDUWPHQW $YLDWLRQ3DUN'ULYH /RQGRQGHUU\1+ ,QWHUQDWLRQDO ZZZEXUQG\FRP 0DWHULDOWLQSODWHGFRSSHU 2XWGRRUUDWHG /RZSUR¿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¿OHRIWKH:,/(<*URXQGLQJ/XJDOORZVLWWREHLQVWDOOHGLQDYDULHW\RISRVLWLRQV Catalog Item # L x W x H Hole Hardware Torque :,/(</8* ´[´[´´7HUPLQDOVFUHZLQFOXGHG :((%70QRWLQFOXGHG IWOEVIRU WHUPLQDOVFUHZ IWOEVIRU PRXQWLQJ KDUGZDUH Z3HQHWUR[$ RQWKUHDGV :,/(</8* ´[´[´ ´ 7HUPLQDOVFUHZLQFOXGHG :((%70QRWLQFOXGHG :,/(</8* ´[´[´ 7HUPLQDOVFUHZLQFOXGHG :((%70QRWLQFOXGHG :,/(</8* ´[´[´ 7HUPLQDOVFUHZLQFOXGHG :((%70QRWLQFOXGHG &XVWRPHU6HUYLFH'HSDUWPHQW $YLDWLRQ3DUN'ULYH /RQGRQGHUU\1+ ,QWHUQDWLRQDO ZZZEXUQG\FRP S 2XWGRRU UDWHG Volume 1—Residential and Light Commercial CA08100002E—January 2013 www.eaton.com V1-T1-47 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Single-Phase—Main Lug Loadcenters Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral Notes 1 Ground bar kits priced separately. See Page V1-T1-60. – For 2/4 circuit loadcenters, use GBK5 or GBK520 ground bar. – For 4/8, 6/12 and 8/16 circuit loadcenters, use GBK10 ground bar. – Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters. 2 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 3 Ground bar GBK5 is installed. 4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-60. 5 CSA and UL approved. 6 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/Al. 7 For use as service entrance applications only. 8 Neutral/ground holes (6) #14–6 and (3) #14–1/0 AWG Cu/Al. 9 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). j Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). k Ground bar GBK10 is installed. l Ground bar GBK14 is installed. Box sizes Pages V1-T1-61 through V1-T1-64. Main Ampere Rating Maximum Number 1-Inch (25.4 mm)Enclosure Type Trim Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Loadcenter Catalog NumberSpaces Circuits 70 2 4 Indoor Surface (no door) 5 #8–#2 BR24L70SP 12 2 4 Indoor Surface (no door) 5 BR24L70SGP 23 2 4 Outdoor —5R BR24L70RP 124 2 4 Indoor Flush (no door) 5 BR24L70FP 12 2 4 Indoor Flush (no door) 5 BR24L70FGP 25 125 2 4 Indoor Surface (no door) 6 #14–1/0 BR24L125SP 12 2 4 Outdoor —6R BR24L125RP 124 2 4 Outdoor —6R BR24L125RSEP 278 2 4 Outdoor —6R BR24L125RSE2P 267 2 4 Indoor Flush (no door) 6 BR24L125FP 12 4 8 Indoor Surface (no door) 7 #14–1/0 BR48L125SP 19 4 8 Indoor Surface (no door) 7 BR48L125SGP 39 4 8 Outdoor —7R BR48L125RP 149 4 8 Indoor Flush (no door) 7 BR48L125FP 19 4 8 Indoor Flush (with door) 7 BR48L125FDP 19 4 8 Indoor Flush (no door) 7 BR48L125FGP 39 6 12 Indoor Surface (no door) 7 #14–#1 BR612L125SP 1j 6 12 Indoor Surface (no door) 7 BR612L125SGP jk 6 12 Indoor Surface (with door) 7 BR612L125SDP 1j 6 12 Indoor Surface (with door) 7 BR612L125SDGP jk 6 12 Outdoor —7R BR612L125RP 14j 6 12 Indoor Flush (no door) 7 BR612L125FP 1j 6 12 Indoor Flush (no door) 7 BR612L125FGP 5jk 6 12 Indoor Flush (with door) 7 BR612L125FDP j 6 12 Indoor Flush (with door) 7 BR612L125FDGP 5jk 8 16 Indoor Surface (no door) 7 #14–#1 BR816L125SP 1j 8 16 Indoor Surface (no door) 7 BR816L125SGP jl 8 16 Indoor Surface (with door) 7 BR816L125SDP 1j 8 16 Indoor Surface (with door) 7 BR816L125SDGP jl 8 16 Outdoor —7R BR816L125RP 14j 8 16 Indoor Flush (no door) 7 BR816L125FP 1j 8 16 Indoor Flush (no door) 7 BR816L125FGP 5jl 8 16 Indoor Flush (with door) 7 BR816L125FDP 1j 8 16 Indoor Flush (with door) 7 BR816L125FDGP 5jl Surface Outdoor Flush Outdoor Surface (No Door) Flush (No Door) Outdoor V1-T1-66 Volume 1—Residential and Light Commercial CA08100002E—December 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Dimensions Approximate Dimensions in Inches (mm) Residential/Commercial/New York City Loadcenters, Unit Enclosures—Box Sizes Note: Box sizes do not include covers/fronts. Residential Loadcenters—NEMA Type 1 Indoor Residential Loadcenters—NEMA Type 3R Outdoor Commercial Loadcenters—NEMA Type 1 Indoor Commercial Loadcenters—NEMA Type 3R Outdoor New York City Loadcenters—NEMA Type 1 Indoor Types ECB and ECC Unit Enclosures—NEMA Type 1 Indoor Types ECB and ECC Unit Enclosures—NEMA Type 3R Outdoor Box Size Height Width Depth A1 15.00 (381.0) 11.25 (285.8) 3.75 (95.3) B1 16.75 (425.5) 14.31 (363.5) 3.88 (98.4) B2 18.75 (476.3) 14.31 (363.5) 3.88 (98.4) C1 21.00 (533.4) 14.31 (363.5) 3.88 (98.4) C2 23.00 (584.2) 14.31 (363.5) 3.88 (98.4) C4 27.00 (685.8) 14.31 (363.5) 3.88 (98.4) D1 29.13 (739.8) 14.31 (363.5) 3.88 (98.4) G1 34.13 (866.8) 14.31 (363.5) 3.88 (98.4) L1 39.00 (990.6) 14.31 (363.5) 3.88 (98.4) L2 45.00 (1143.0) 14.31 (363.5) 3.88 (98.4) L3 48.38 (1228.3) 14.31 (363.5) 3.88 (98.4) 2 8.63 (219.1) 5.00 (127.0) 3.50 (88.9) 3 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 4 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 5 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 6 12.00 (304.8) 6.88 (174.6) 4.50 (114.3) 7 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 9 14.50 (368.3) 6.50 (165.1) 3.50 (88.9) Box Size Height Width Depth B1R 16.75 (425.5) 14.31 (363.5) 5.19 (131.8) B2R 18.75 (476.3) 14.31 (363.5) 5.19 (131.8) C3R 25.00 (635.0) 14.31 (363.5) 5.19 (131.8) D1R 29.13 (739.8) 14.31 (363.5) 5.19 (131.8) G1R 34.13 (866.8) 14.31 (363.5) 5.19 (131.8) L1R 39.00 (990.6) 14.31 (363.5) 5.19 (131.8) L2R 45.00 (1143.0) 14.31 (363.5) 5.19 (131.8) L3R 48.75 (1238.2) 14.31 (363.5) 5.19 (131.8) 2R 8.63 (219.1) 5.00 (127.0) 3.50 (88.9) 3R 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 4R 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 5R 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 6R 11.75 (298.5) 6.50 (165.1) 4.50 (114.3) 7R 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 8R 27.00 (685.8) 10.50 (266.7) 4.75 (120.7) 9R 14.25 (362.0) 6.50 (165.1) 4.00 (101.6) C1R 21.00 (533.4) 14.31 (363.5) 5.19 (131.8) Box Size Height Width Depth 19 44.00 (1117.6) 16.16 (410.4) 6.25 (158.8) 20 44.00 (1117.6) 16.16 (410.4) 6.25 (158.8) 22 54.00 (1371.6) 16.22 (412.0) 6.31 (160.3) 24 66.50 (1689.1) 16.22 (412.0) 6.31 (160.3) Box Size Height Width Depth 42 38.00 (965.2) 16.31 (414.3) 6.38 (161.9) 43 44.00 (1117.6) 16.31 (414.3) 6.38 (161.9) 46 54.00 (1371.6) 16.31 (414.3) 6.38 (161.9) 47 66.56 (1690.7) 16.31 (414.3) 6.38 (161.9) Box Size Height Width Depth A 38.00 (965.2) 18.13 (460.4) 5.00 (127.0) B 44.00 (1117.6) 18.13 (460.4) 5.00 (127.0) C 66.50 (1689.1) 18.13 (460.4) 6.25 (158.8) Height Width Depth 23.25 (590.6) 8.88 (225.4)4.50 (114.3) Height Width Depth 23.68 (601.7)9.31 (236.5)5.44 (138.1)