Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SOLR22-0876 APPROVED REVISED PLANS.pdf
COVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS A AC AFCI AZIM COMP DC (E) ESS EXT INT MAG MSP (N) NTS OC PRE-FAB PSF PV RSD TL TYP V W AMPERE ALTERNATING CURRENT ARC FAULT CIRCUIT INTERRUPTER AZIMUTH COMPOSITION DIRECT CURRENT EXISTING ENERGY STORAGE SYSTEM EXTERIOR INTERIOR MAGNETIC MAIN SERVICE PANEL NEW NOT TO SCALE ON CENTER PRE-FABRICATED POUNDS PER SQUARE FOOT PHOTOVOLTAIC RAPID SHUTDOWN DEVICE TRANSFORMERLESS TYPICAL VOLTS WATTS PAGE REV: B 8/19/2022 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 RONALD COCHRAN 77601 ASHBERRY CT, PALM DESERT, CA, 92211 PROJECT NUMBER: 113R-601COCH SHEET DESIGNER: LEONARDO UGALDO CUSTOMER RESIDENCE: TEL. (760) 636-8438 APN: 632-600-028 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-1.0 LEGEND AND ABBREVIATIONS SCALE: NTS MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER SERVICE ENTRANCE IQ COMBINER BOX HARDSCAPE PROPERTY LINEINTERIOR EQUIPMENT SHOWN AS DASHED PL RAIL STANDOFFS & FOOTINGS SOLAR MODULES SE MP SP LC SM PM INV AC DC VICINITY MAP • ALL WORK SHALL COMPLY WITH 2019 CRC/CBC/CEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2019 CEC. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2019 CEC. • PHOTOVOLTAIC SYSTEM IS FUNCTIONALLY GROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER 690.12(B). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 11.14 AMPS MODULE SHORT CIRCUIT CURRENT. • 17.4 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • CONSTRUCTION WORK HOURS OCTOBER 1ST TO APRIL 30TH MONDAY - FRIDAY 7:00AM TO 5:30PM SATURDAY 8:00AM TO 5:00PM SUNDAY NOT ALLOWED GOVERNMENT HOLIDAY CONSTRUCTION WORK NOT ALLOWED CONSTRUCTION WORK HOURS - MAY 1ST THROUGH SEPTEMBER 30TH MONDAY - FRIDAY 6:00AM TO 7:00PM SATURDAY 8:00AM TO 5:00PM SUNDAY NOT ALLOWED GOVERNMENT HOLIDAY CONSTRUCTION WORK NOT ALLOWED #SSTAMPCS #ESTAMPCS TABLE OF CONTENTS PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE • NEW 100AMP SUB-PANEL TO BE INSTALLED. B • SYSTEM SIZE: 7600W DC, 6000W AC • MODULES: (19) HANWHA Q-CELLS: Q.PEAK DUO BLK ML-G10+ 400 • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: SE6000H-USSN • RACKING: ADJUSTABLE TILE HOOK, SEE DRAWING SNR-DC-00437 • MAIN BREAKER DERATE: REPLACE EXISTING 200 AMP MAIN BREAKER WITH NEW 150 AMP 22K AIC RATED MAIN BREAKER. PL PL PL PL PL PLPLPL PL PL PL PL PL PL PL PL PAGE REV: B 8/19/2022 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 RONALD COCHRAN 77601 ASHBERRY CT, PALM DESERT, CA, 92211 PROJECT NUMBER: 113R-601COCH SHEET DESIGNER: LEONARDO UGALDO CUSTOMER RESIDENCE: TEL. (760) 636-8438 APN: 632-600-028 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 SITE PLAN ARRAY PITCH PV AREA (SQFT) AR-01 17° 232.3 AR-02 17° 16990° TRUE AZIM MAG AZIM 168°180° 78° PV-2.0 #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = 1/16" = 1'-0" ELEVATION VIEW - SCALE = 3/64" = 1'-0" 5.5" 18' ASHBERRY CT MP SE AC (E) DRIVEWAY INV INV AC (N) ARRAY AR-02 (E) RESIDENCE LADDER ACCESS POINT(E) POOL (N) ARRAY AR-01 FIRE SETBACKS (18" TYP) (E) PV ARRAY (E) GATE (E) GATE LADDER ACCESS POINT (E) GATE/FENCE AC ROOF PATHWAYS (3' TYP) ROOF PATHWAYS (3' TYP) NOTES: x RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: x TOTAL ROOF SURFACE AREA: 4042 SQFT. x NEW PV ARRAY AREA: 401.3 SQ FT. x EXISTING PV ARRAY AREA: 421.7 SQ FT. x TOTAL PV ARRAY AREA: 833.5 SQ FT. x PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 20.6% MODULES WERE DESIGNED AT LEAST 18'' FROM THE ROOF RIDGE. B PAGE REV: B 8/19/2022 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 RONALD COCHRAN 77601 ASHBERRY CT, PALM DESERT, CA, 92211 PROJECT NUMBER: 113R-601COCH SHEET DESIGNER: LEONARDO UGALDO CUSTOMER RESIDENCE: TEL. (760) 636-8438 APN: 632-600-028 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-3.0 LAYOUT #SSTAMP ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 CONCRETE TILE [CURVED - S] - TILE HOOK - UR 1-Story 2X4 PRE-FABRICATED TRUSSES 6' - 3"24"ADJUSTABLE TILE HOOK, SEE DRAWING SNR-DC-00437 6' - 0" 2' - 4" 6' - 0" 2' - 2" STACKED AR-02 CONCRETE TILE [CURVED - S] - TILE HOOK - UR 1-Story 2X4 PRE-FABRICATED TRUSSES 4' - 9"24"ADJUSTABLE TILE HOOK, SEE DRAWING SNR-DC-00437 6' - 0"2' - 4"6' - 0"2' - 2" STACKED DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 0 PSF WIND SPEED: 130 MPH 3-SEC GUST. S.S.LAG SCREWS: 5/16"x4.5": 2.5" MIN EMBEDMENT STRUCTURAL NOTES: x INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. x IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: xx ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% xx ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS 5.5" SOLAR MODULE SNAPNRACK RACKING AND TILE ROOF HOOK MODULE ELEVATION DETAIL - SCALE: NTS D1 - AR-01 - SCALE: 1/8" = 1'-0" AZIM: 180° PITCH: 17° D2 - AR-02 - SCALE: 1/8" = 1'-0" AZIM: 90° PITCH: 17°1'-9" 20'-11"19'-8" 8'-3" 12'-5" 2'-4" 6' TYP 7'-5"17'-5"26'-9" 8'-4" 12'-5" 1'-7" 6' TYP NEW 150A MAIN BREAKER (END FED) EXISTING 200A MAIN PANELFACILITY LOADS FACILITY GROUND(N) 35A PV BREAKER AT OPPOSITE END OF BUSBAR NEW 100A SUB PANEL (6) 15A 1-1P TWIN RELOCATED BREAKERS(N) 30A SUB- FEEDER BREAKER 4 M METER #: SDG&E 222012227584 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC 3 JUNCTION BOX OR EQUIVALENT 12 SOLAREDGE TECHNOLOGIES: SE6000H-USSN WITH REVENUE GRADE METERING 6000 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI, RAPID SHUTDOWN COMPLIANT PV MODULES HANWHA Q-CELLS: Q.PEAK DUO BLK ML-G10+ 400 (19) MODULES OPTIMIZERS WIRED IN: (1) SERIES OF (11) OPTIMIZERS (1) SERIES OF (8) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS P401 (E) JUNCTION BOX OR EQUIVALENT EXISTING SYSTEM E E E (1) SUNPOWER: SPR-7000M 7000 WATT INVERTER INVE1 PV MODULES SUNPOWER: SPR-327NE-WHT-D (24) MODULES 327 INVE1 (E) LOCKABLE BLADE TYPE AC DISCONNECT (E) LOCKABLE BLADE TYPE AC DISCONNECT E (E) 40A PV BREAKER E CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(4) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 E EXISTING PAGE REV: B 8/19/2022 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 RONALD COCHRAN 77601 ASHBERRY CT, PALM DESERT, CA, 92211 PROJECT NUMBER: 113R-601COCH SHEET DESIGNER: LEONARDO UGALDO CUSTOMER RESIDENCE: TEL. (760) 636-8438 APN: 632-600-028 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-4.0 ELECTRICAL #ESTAMP RAIL 6-12 AWG BARE COPPER WIRE 5/16"-18 SS BOLT SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) SNAPNRACK GROUND LUG BONDING CHANNEL NUT SS BONDING PINS NOTE: x ALL HARDWARE IS INCLUDED FROM MANUFACTURER x A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES x GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL x GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL x ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS ALL CONDUCTORS ARE RATED 90 DEGREES CELSIUS. SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DC VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT: 7600 W 11 V 380 V 480 V 20 A 30 A P401 OPTIMIZER CHARACTERISTICS: MIN INPUT VOLTAGE: 8 VDC MAX INPUT VOLTAGE: 60 VDC MAX INPUT ISC:11.75 ADC MAX OUTPUT CURRENT: 15 ADC MODULE CHARACTERISTICS HANWHA Q-CELLS: Q.PEAK DUO BLK ML-G10+ 400: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 400 W 45.3 V 37.13 V 11.14 A B B PAGE REV: B 8/19/2022 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 RONALD COCHRAN 77601 ASHBERRY CT, PALM DESERT, CA, 92211 PROJECT NUMBER: 113R-601COCH SHEET DESIGNER: LEONARDO UGALDO CUSTOMER RESIDENCE: TEL. (760) 636-8438 APN: 632-600-028 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP PV SYSTEM DISCONNECT FOR UTILITY OPERATION LABEL LOCATION: UTILITY DISCONNECT ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), NEC 2017: 705.12(B)(2)(3)(c) NOTES AND SPECIFICATIONS: x SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2019 CEC ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. x SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. x LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. x LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. x SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. x DO NOT COVER EXISTING MANUFACTURER LABELS. INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE: MAXIMUM CIRCUIT CURRENT: MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED): VDC ADC ADC 480 30 15 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53 LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4) IFC 2012: 605.11.1.4 WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2019: 705.12(B)(3), NEC 2017: 705.12(B)(3) WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b) LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): CEC 2019: 690.56(C)(3), NEC 2017: 690.56(C)(3), IFC 2012: 605.11.1, IFC 2018: 1204.5.3, CFC 2019: 1204.5.3 ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.13(B), NEC 2017: 690.13(B) ! PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): CEC 2019: 690.56(C)(1)(a), NEC 2017: 690.56(C)(1)(a) 4" 3" POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: 77601 ASHBERRY CT, PALM DESERT, CA, 92211 UTILITY METER AND PV BREAKER DISCONNECT(E) PV EQUIPMENT INVERTER (EXT) (E) SOLAR PANELS ON ROOF SOLAR PANELS ON ROOF AC DISCONNECT (EXT) LABEL LOCATION: MAIN SERVICE PANEL ADJACENT TO MAIN SERVICE BREAKER. PER CODE(S): NEC 2020: 705.12(B)(3)(2), NEC 2017: 705.12(B)(2)(3)(b), NEC 2014: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4), CEC 2019: 705.12(B)(2)(3)(b) UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS INSTALLED ASSEMBLY ATTACHMENT DETAIL OFFSET DETAIL SECTION D-D SCALE 7:24 SECTION E-E SCALE 1 / 4 ATTACHMENT DETAIL CDDEE DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR Ɣ SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 Ɣ FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, ULTRA RAIL ADJUSTABLE TILE HOOK TO RAFTERSNR-DC-00437 1 2/6/2020 NEW DETAIL 2 11/6/2020 EDITED NOTES REV: 2DATE: DNS 11/6/2020 DRAFTER:D.RYAN W.ARBUCKLE D.RYAN Solar Mounting Solutions DR DR1 BIN: 15 8 " 11 2 " 11 2 " 21 4 " SNAPNRACK ADJUSTABLE TILE HOOK FOR USE WITH SNAPNRACK ULTRA RAIL TILE ROOF MOUNT ASSEMBLY MAY BE USED FOR S, W, AND FLAT TILE PROFILE ROOFS REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. "BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS DRAWING 5 16 "P S.S. LAG SCREWS MUST EMBED A MIN. OF 21 2 " INTO STRUCTURAL MEMBER REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5 16 "P HARDWARE TORQUE SPECIFICATIONS UNLESS STATED OTHERWISE RAIL MAY BE MOUNTED TO THE UPSLOPE OR DOWNSLOPE SIDE OF THE TILE HOOK RAILS CAN BE LEVELED UP TO 11 4 " USING THE SLOT IN THE TILE HOOK TILE HOOK ARM CAN BE LEVELED 7 16 " RELATIVE TO THE BASE STRUCTURAL MEMBER SPECIFICATIONS: MINIMUM WOOD GRADE = SPF #2 MINIMUM SPECIFIC GRAVITY = 0.42 ALLOWABLE FASTENER UPLIFT = 820 LBS ALLOWABLE FASTENER LATERAL = 250 LBS MINIMUM FASTENER EDGE DISTANCE = 0.5" MINIMUM FASTENER END DISTANCE = 2.2" STEP 1: REMOVE TILES TO EXPOSE ROOF DECKING SEALANT STEP 2: DRILL 2 QTY. 3 16 " PILOT HOLES INTO RAFTER. SEAL ROOF PENETRATIONS WITH APPROPRIATE SEALANT. FASTEN BASE TO ROOF WITH 2 QTY. 5 16 " LAG SCREWS WITH FLAT WASHERS ROOF TILE ("S" PROFILE), TYP. STRUCTURAL MEMBER, WOOD RAFTER, TYP. ROOF DECKING, TYP. ENSURE 21 2 " MINIMUM EMBEDMENT INTO WOOD MEMBER TILE BATTEN, TYP. ROOF DECKING, TYP. ROOF TILES ("S" PROFILE), TYP. STRUCTURAL MEMBER (RAFTER) HOOK ARM CAN BE OFFSET FROM RAFTER UP TO 6" IN EITHER DIRECTION TO LINE UP WITH LOW POINT IN S-TILES MODULE HEIGHT OFF ROOF, RANGE: UR-40: 71 4 " - 815 16 " UR-60: 77 8 " - 99 16 " P5 16 " STAINLESS LAG SCREWS WITH 5 16 " STAINLESS FLAT WASHERS UR-60 RAIL (UR-40 RAIL SIMILAR) SNAPNRACK ADJUSTABLE TILE HOOK ARM MAY BE RELOCATED ON BASE WHERE REQUIRED SNAPNRACK ADJUSTABLE TILE HOOK BASE SNAPNRACK UR-60 RAIL SNAPNRACK ULTRA RAIL ADJUSTABLE TIE HOOK ASSEMBLY P5 16 " STAINLESS CARRIAGE BOLT WITH FLANGE NUT R E E N I IGER LARUTCURTS AINROFILACFOETAT S G N E LANOISSEFORPDERETSE H C A Z HTENEKL N AP Exp. 3-31-23 No. S3878 R U BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21.4%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new “Quality Controlled PV” of the independent certification institute TÜV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology 1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400Pa) and wind loads (4000Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. 1 APT test conditions according to IEC/TS 62804-1:2015, method A (−1500V, 96h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Q.PEAK DUO ML-G10+ 395-415 ENDURING HIGH PERFORMANCE 76.4in 1940mm 43.3in 1100mm 48.0in 1220mm 1656lbs 751kg 24 24 32 Į [%/K] +0.04 ȕ [%/K] −0.27 Ȗ [%/K] −0.34 NMOT [°F] 109±5.4 (43±3°C) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us [V] 1000 (IEC)/1000 (UL)Class II [A DC] 20 TYPE 2 [lbs/ft2] 75 (3600Pa)/55 (2660Pa) −40°F up to +185°F (−40°C up to +85°C)[lbs/ft2] 113 (5400Pa)/84 (4000Pa) 3 See Installation Manual 395 400 405 410 415 [W] 395 400 405 410 415 [A] 11.13 11.16 11.19 11.22 11.26 [V] 45.03 45.06 45.09 45.13 45.16 [A] 10.58 10.64 10.70 10.76 10.82 [V] 37.32 37.59 37.85 38.11 38.37 [%] ≥20.1 ≥20.4 ≥20.6 ≥20.9 ≥21.1 [W] 296.4 300.1 303.9 307.6 311.4 [A] 8.97 8.99 9.02 9.04 9.07 [V] 42.46 42.49 42.52 42.56 42.59 [A] 8.33 8.38 8.43 8.48 8.53 [V] 35.59 35.82 36.04 36.27 36.49 53' 40'HC Certified UL 61730 MECHANICAL SPECIFICATION Format 74.0in × 41.1in × 1.26in (including frame) (1879mm × 1045mm × 32mm) Weight 48.5lbs (22.0kg) Front Cover 0.13in (3.2mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in × 1.26-2.36in × 0.59-0.71in (53-101mm × 32-60mm × 15-18mm), IP67, with bypass diodes Cable 4mm² Solar cable; (+) ≥49.2in (1250mm), (−) ≥49.2in (1250mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © Q C E L L S Q. P E A K D U O M L - G 1 0 + _ 3 9 5 - 4 1 5 _ 2 0 2 1 - 0 5 _ R e v 0 1 _ N A ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5W/−0W) Mi n i m u m Power at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 Ș MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Mi n i m u m Power at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances PMPP ±3%; ISC; VOC ±5% at STC: 1000W/m2, 25±2°C, AM 1.5 according to IEC 60904-3 • 2 800W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98% of nominal power during first year. Thereafter max. 0.5% degradation per year. At least 93.5% of nominal power up to 10 years. At least 86% of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25°C, 1000W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Maximum Series Fuse Rating Fire Rating based on ANSI/UL 61730 Max. Design Load, Push/Pull3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push/Pull3 DETAIL A 0.63" (16 mm) 0.33" (8.5 mm)0.96" (24.5 mm) 42.8" (1088 mm) 74.0" (1879 mm) 4 × Mounting slots (DETAIL A) Frame 41.1" (1045 mm) 39.2" (996 mm) 1.26" (32 mm) 8 × Drainage holes 15.6“ (395.5 mm) 4 × Grounding points ø 0.18" (4.5 mm) Label 49.2" (1250 mm) 49.2" (1250 mm) RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P O W E R [ % ] YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 1552520010 98 86 200 400 600 800 1000 110 100 90 80 RE L A T I V E E F F I C I E N C Y [ % ] IRRADIANCE [W/m²] QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 61730, CE-compliant, Quality Controlled PV - TÜV Rheinland, IEC 61215:2016, IEC 61730:2016, U.S. Patent No. 9,893,215 (solar cells), QCPV Certification ongoing. Horizontal packaging pallets pallets modules ST O R E D G E ® solaredge.com Optimized battery storage with HD-Wave technology 5HFRUGEUHDNLQJZHLJKWHGHIÀFLHQF\ZLWK 200% DC oversizing Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020, per article 690.11 and 690.12 Embedded revenue grade production data, ANSI C12.20 Class 0.5 6PDOOOLJKWZHLJKWDQGHDV\WRLQVWDOO 0RGXODUGHVLJQIXWXUHUHDG\ZLWKRSWLRQDO upgrades to: Multi-inverter(*), scalable storage solution Single Phase Energy Hub Inverter with Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US 12-25 YEARWARRANTY DC-coupled storage for full or partial home backup Built-in consumption monitoring Direct connection to the SolarEdge smart EV charger SE3000H-US SE3800H-US SE6000H-US SE7600H-US UNITS OUTPUT - AC ON GRID Rated AC Power 3000 3800 6000 7600 W Maximum AC Power Output 3000 3800 6000 7600 W AC Output Voltage Range 211-264 Vac AC Frequency Range (min - nom - max)59.3 - 60 - 60.5(2)Hz Maximum Continuous Output Current 12.5 16 25 32 A GFDI Threshold 1A 7RWDO+DUPRQLF'LᐎRUWLRQ7+'<3 % Power Factor DGMXᐎDEOHWR 8WLOLW\0RQLWRULQJ,VODQGLQJ3URWHFWLRQ&RXQWU\&RQÀJXUDEOH7KUHVKROGV Yes Charge Battery from AC (if Allowed)Yes Typical Nighttime Power Consumption <2.5 W OUTPUT - AC BACKUP(3) Rated AC Power in Backup Operation 2400 3050 4800 6100 W Peak AC Power (<10 sec) in Backup Operation 2700 3400 5400 6900 W AC L-L Output Voltage Range in Backup 211-264 Vac AC L-N Output Voltage Range in Backup 105-132 Vac AC Frequency Range in Backup (min - nom - max) 55 - 60 - 65 Hz Maximum Continuous Output Current in Backup Operation 10 12.7 20 25.5 A Peak AC Current (<10sec) in Backup Operation 11.25 14.2 22.5 30 A GFDI 1A THD <5 % OUTPUT - SMART EV CHARGER AC Rated AC Power 9,600 W AC Output Voltage Range 211-264 Vac AC Frequency Range (min - nom - max) 59.3-60-60.5 Hz 0D[LPXP&RQWLQXRXV2XWSXW&XUUHQW#9JULG39DQGEDWWHU\40 Aac INPUT - DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 400 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection NƼ6HQVLWLYLW\ INPUT - DC (PV) Maximum DC Power 6000 7600 12000 15600 W Maximum Input Current(4)8.5 10.5 16.5 20 Adc 0D[,QSXW6KRUW&LUFXLW&XUUHQW 45 Adc 0D[LPXP,QYHUWHU(FLHQF\99.2 % &(&:HLJKWHG(FLHQF\99 % 2-pole Disconnection Yes INPUT - DC (BATTERY) 6XSSRUWHG%DWWHU\7\SHV /*&KHP5(68+ 1XPEHURI%DWWHULHVSHU,QYHUWHU 1 or 2(5) Maximum Battery Capacity per Inverter 19.6 kWh Continuous Power Per Inverter 5000 W Peak Power 6900 W Max Input Current @240V 18 Adc 2-pole Disconnection Yes Single Phase Energy Hub Inverter with Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1) SMART ENERGY CAPABILITIES Consumption Metering Built - in(6) %DWWHU\6WRUDJH With Backup Interface for service up to 200A; Up to 3 inverters*N:EDFNXSSRZHU*, and 60kWh EDFNXSFDSDFLW\* EV Charging 'LUHFWFRQQHFWLRQWR6PDUW(9FKDUJHU ADDITIONAL FEATURES 6XSSRUWHG&RPPXQLFDWLRQ,QWHUIDFHV 56(WKHUQHW:L)LRSWLRQDO&HOOXODU(7) 5HYHQXH*UDGH0HWHULQJ$16,&Built - in(6) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning ZLWKWKH6HW$SSPRELOHDSSOLFDWLRQXVLQJEXLOWLQ:L)L$FFHVV3RLQWIRUORFDOFRQQHFWLRQ '&9ROWDJH5DSLG6KXWGRZQ39DQG%DWWHU\Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12 STANDARD COMPLIANCE 6DIHW\8/8/6$8/%8/8/&6$ *ULG&RQQHFWLRQ6WDQGDUGV IEEE1547, Rule 21, Rule 14H Emissions FCC part 15 class B INSTALLATION SPECIFICATIONS $&2XWSXW&RQGXLW6L]H$:*5DQJH PD[LPXP$:* PD[LPXP$:* (9$&2XWSXW&RQGXLW6L]H$:*5DQJH PD[LPXP$:* PD[LPXP$:* '&,QSXW39&RQGXLW6L]H$:*5DQJH PD[LPXP$:* PD[LPXP$:* '&,QSXW%DWWHU\&RQGXLW6L]H$:*5DQJH PD[LPXP$:* PD[LPXP$:* Dimensions with Connection Unit (HxWxD);;;; LQPP Weight with Connection Unit OENJ Noise < 25 dBA Cooling Natural Convection Operating Temperature Range WRWR(7)Ü)Ü& Protection Rating NEMA 4X © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 11/2020/V01/ENG NAM. Subject to change without notice. 3HQGLQJÀUPZDUHXSJUDGH 7KHVHVSHFLÀFDWLRQVDSSO\WRLQYHUWHUVZLWKSDUWQXPEHUV6([[[[+866[[[[[RU6(+8666+[[[[DQGFRQQHFWLRQXQLWPRGHOQXPEHU'&'3+863[+)[ )RURWKHUUHJLRQDOVHWWLQJVSOHDVHFRQWDFW6RODU(GJHVXSSRUW (3) Not designed for standalone applications and requires AC for commissioning $KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVVWDWHG :KHQFRQQHFWLQJWZR/*&KHP5(68EDWWHULHVHDFKEDWWHU\PXVWKDYHDGLIIHUHQWSDUWQXPEHU )RUFRQVXPSWLRQPHWHULQJFXUUHQWWUDQVIRUPHUVVKRXOGEHRUGHUHGVHSDUDWHO\6($&71$RU6($&71$XQLWVSHUER[ )RUERWK\UDQG\UGDWDSODQV Ã&XVWRPHULVUHVSRQVLEOHIRUYHULI\LQJWKDWWKHVLWHORFDWLRQKDVDGHTXDWHPRELOHFRYHUDJHE\WKHWKLUGSDUW\VHUYLFHSURYLGHUSULRUWRDQ\LQVWDOODWLRQE\DFFHVVLQJ https://www.solaredge.com/ ֿ products/communication/cellular-communication-options#/ Ã6RODU(GJHVKDOOQRWEHUHVSRQVLEOHRUOLDEOHIRUXQDYDLODELOLW\RUGLVFRQWLQXDQFHRIQHWZRUNFRYHUDJHLQDVSHFLÀFDUHDRUUHJLRQDQ\QHWZRUNGRZQWLPHRUSHUPDQHQWVHUYLFHVKXWGRZQ )XOOSRZHUXSWRDWOHDVW&)IRUSRZHUGHUDWLQJLQIRUPDWLRQUHIHUWRKWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI Connecting CTs to the Revenue Grade and Consumption Meter 6LQJOH3KDVH(QHUJ\+XE,QYHUWHU ZLWK3ULVP7HFKQRORJ\ Grid Single Phase Energy Hub Inverter with Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1) PO W E R O P T I M I Z E R solaredge.com PV power optimization at the module-level 6SHFLÀFDOO\GHVLJQHGWRZRUNZLWK6RODU(GJH LQYHUWHUV 8SWRPRUHHQHUJ\ )OH[LEOHV\VWHPGHVLJQIRUPD[LPXPVSDFH XWLOL]DWLRQ )DVWLQVWDOODWLRQZLWKDVLQJOHEROW 1H[WJHQHUDWLRQPDLQWHQDQFHZLWKPRGXOH OHYHOPRQLWRULQJ 0HHWV1(&UHTXLUHPHQWVIRUDUFIDXOW SURWHFWLRQ$)&,DQG3KRWRYROWDLF5DSLG 6KXWGRZQ6\VWHP39566 0RGXOHOHYHOYROWDJHVKXWGRZQIRULQVWDOOHU DQGÀUHÀJKWHUVDIHW\ 6XSHULRUHIÀFLHQF\ 0LWLJDWHVDOOW\SHVRIPRGXOHPLVPDWFKORVVHV IURPPDQXIDFWXULQJWROHUDQFHWRSDUWLDO VKDGLQJ Power Optimizer For North America 33333333 25 YEARWARRANTY 6RODU(GJH7HFKQRORJLHV/WG$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF $OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH )RUGHWDLOHGᐎULQJVL]LQJLQIRUPDWLRQUHIHUWRKWWSZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVᐎULQJBVL]LQJBQDSGI ,WLVQRWDOORZHGWRPL[333ZLWK33333LQRQHᐎULQJ $ᐎULQJZLWKPRUHWKDQRSWLPL]HUVGRHVQRWPHHW1(&UDSLGVKXWGRZQUHTXLUHPHQWVVDIHW\YROWDJHZLOOEHDERYHWKH9UHTXLUHPHQW )RU9JULGLWLVDOORZHGWRLQᐎDOOXSWR:SHUᐎULQJZKHQWKHPD[LPXPSRZHUGLHUHQFHEHWZHHQHDFKᐎULQJLV: )RU9JULGLWLVDOORZHGWRLQᐎDOOXSWR:SHUᐎULQJZKHQWKHPD[LPXPSRZHUGLHUHQFHEHWZHHQHDFKᐎULQJLV: Power Optimizer For North America 33333333 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cell modules) P370 (for higher- power 60 and 72- cell modules) P400 (for 72 & 96-cell modules) P401 (for high power 60 and 72 cell modules) P405 (for high- voltage modules) P485 (for high- voltage modules) P505 (for higher current modules) INPUT 5DWHG,QSXW'&3RZHU : $EVROXWH0D[LPXP,QSXW9ROWDJH 9RFDWORZHᐎWHPSHUDWXUH 9GF 03372SHUDWLQJ5DQJH 9GF 0D[LPXP6KRUW&LUFXLW&XUUHQW (Isc) Adc 0D[LPXP'&,QSXW&XUUHQW Adc 0D[LPXP(FLHQF\% :HLJKWHG(FLHQF\98.8 % 2YHUYROWDJH&DWHJRU\II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) 0D[LPXP2XWSXW&XUUHQW Adc 0D[LPXP2XWSXW9ROWDJH 9GF OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) 6DIHW\2XWSXW9ROWDJHSHU3RZHU 2SWLPL]HU 9GF STANDARD COMPLIANCE (0&)&&3DUW&ODVV%,(&,(& 6DIHW\,(&FODVV,,VDIHW\8/ 0DWHULDO 8/9895HVLᐎDQW 5R+6 Yes INSTALLATION SPECIFICATIONS 0D[LPXP$OORZHG6\ᐎHP 9ROWDJH 9GF &RPSDWLEOHLQYHUWHUV $OO6RODU(GJH6LQJOH3KDVHDQG7KUHH3KDVHLQYHUWHUV 'LPHQVLRQV:[/[+ [[[[ [[ [[ [[ [[[[[[[[ [[ mm LQ :HLJKWLQFOXGLQJFDEOHV JUOE ,QSXW&RQQHFWRU 0& 6LQJOHRUGXDO 0&0& ,QSXW:LUH/HQJWK RU RU PIW 2XWSXW:LUH7\SH&RQQHFWRU 'RXEOH,QVXODWHG0& 2XWSXW:LUH/HQJWK PIW 2SHUDWLQJ7HPSHUDWXUH5DQJH Ü&Ü) 3URWHFWLRQ5DWLQJ ,31(0$3 5HODWLYH+XPLGLW\% 5DWHGSRZHURIWKHPRGXOHDW67&ZLOOQRWH[FHHGWKHRSWLPL]HU´5DWHG,QSXW'&3RZHUµ0RGXOHVZLWKXSWRSRZHUWROHUDQFHDUHDOORZHG 1(&UHTXLUHVPD[LQSXWYROWDJHEHQRWPRUHWKDQ9 )RURWKHUFRQQHFWRUW\SHVSOHDVHFRQWDFW6RODU(GJH )RUGXDOYHUVLRQIRUSDUDOOHOFRQQHFWLRQRIWZRPRGXOHVXVH310'050,QWKHFDVHRIDQRGGQXPEHURI39PRGXOHVLQRQHᐎULQJLQᐎDOOLQJRQH3GXDOYHUVLRQSRZHURSWLPL]HUFRQQHFWHG WRRQH39PRGXOH:KHQFRQQHFWLQJDVLQJOHPRGXOHVHDOWKHXQXVHGLQSXWFRQQHFWRUVZLWKWKHVXSSOLHGSDLURIVHDOV /RQJHULQSXWVZLUHOHQJWKDUHDYDLODEOHIRUXVH)RUPLQSXWZLUHOHQJWKRUGHU3[[[/[[[ )RUDPELHQWWHPSHUDWXUHDERYH&)SRZHUGHUDWLQJLVDSSOLHG5HIHUWR3RZHU2SWLPL]HUV7HPSHUDWXUH'H5DWLQJ7HFKQLFDO1RWHIRUPRUHGHWDLOV PV System Design Using a SolarEdge Inverter(7)(8) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid 0LQLPXP6WULQJ/HQJWK 3RZHU2SWLPL]HUV 333 338 333 8 0D[LPXP6WULQJ/HQJWK3RZHU2SWLPL]HUV (9) 0D[LPXP3RZHUSHU6WULQJ ZLWK 6(866( 86 : 3DUDOOHO6WULQJVRI'LHUHQW/HQJWKVRU2ULHQWDWLRQV Yes Section 220.83 Existing Dwelling Unit Part #1 - Section 220.83 (B)(1) General Lighting/Receptacles @ 3 VA per sq ft: Amps Box A (VA) 32.51 7803 Part #2 - Section 220.83 (B)(2),(3)a, b, c, d - Appliances and Dedicated Circuits: Size in VA Size in VA 1500 N/A 3000 N/A 1000 N/A 600 N/A 1000 N/A 1600 N/A 5760 N/A 7680 N/A 3840 N/A 3840 Amps Box B (VA) N/A 124.25 29820 Total VA from Parts #1 and #2 combined:Box A + Box B =37623 Total VA 37623 First 8,000 VA @ 100%8000 Remaining VA @ 40% Remaining VA =29623 29623 x 40% =11849.2 VA Adding First 8000 VA 8000 VA Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits:19849.2 VA Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits:82.71 Amps Part #3 - Section 220.83 (B) Heating and A/C loads: *Combine the larger loads of either the Heating or the A/C loads togther 100% of all the Heating or A/C loads in VA:12,720 VA 100% of all the Heating or A/C loads in Amps:53.00 A VA Volts Amps Parts #1 & #2 19849.2 240 82.71 Part #3 12,720 240 53.00 Total VA for all Parts:32,569 Totals Service/Feeder Load 135.71 Laundry Appliance Circuit(s) Dishwasher(s) Disposal(s) Dedicated circuit House Square Footage 2601 Article 220 - Service/Feeder calculation for (address): 77601 Ashberry Ct, Palm Desert, CA, 92211 Building VA (watts) 7803 Amps 32.5125 Job Code 113R-601COCH Totals from all Parts Dedicated circuit Total for Part #1: Refrigerator(s) Microwave(s) Totals for Part #2: Dryer Oven Water Pump Water Heater CA-CITY PALM DESERT Building Department Building Permit #: SOLR22-0876 Cochran Residence 77601 Ashberry Ct, Palm Desert, CA, 92211 The following revisions have been made to the plans: Thank you for your time, Austin Harwood Sr. PV System Designer Sunrun 1.Due to a shortage of equipment the modules for this project have been changed to the Hanwha Q-Cells: Q.PEAK DUO BLK ML-G10+ 400. Please see the revision clouds on PV-1.0, PV-2.0, and PV-4.0 that highlight the changes. 2.Due to module swap, system size changed from 7.45kw to 7.6kw 3.Modules decreased from 21 to 19