HomeMy WebLinkAboutPSPA22-0064 PLAN.pdfaccess
3'-6"WD
5'-0"WD
BENCH12"WD
17'-4"
11
'
-
1
1
"
16'-6"
11
'
-
7
"
3'-10"
METALLIC COMPONENTS.
HA
N
I
F
E
N
R
E
S
I
D
E
N
C
E
77
-
9
8
0
W
I
L
D
C
A
T
D
R
I
V
E
,
S
U
I
T
E
2
PA
L
M
D
E
S
E
R
T
,
C
A
CA
-
C
-
5
3
#
1
0
1
0
4
0
3
76
0
.
3
4
5
.
9
7
0
0
75
7
0
6
A
X
I
S
C
T
PA
L
M
D
E
S
E
R
T
,
C
A
POOL DETAILS
SURFACE AREA:
PERIMETER:
SIZE:X
DEPTHS:TO
TYPE:
SURFACE AREA:
PERIMETER:
SIZE:
JETS QTY:
SPILLWAY TYPE:
SPA HEIGHT:
N
FINISH:
EXPANSION JOINTS:
SQ. FT:
CANTILEVER:
STEPS:
STEP FACE:
DECK DRAINS:
SPA DETAILS
DECKING
ACCESS:
ELEVATION:
TYPE:
CONC. REMOVAL:
SOD REMOVAL:
6" R.B.B:
EXCAVATION / STEEL
12" R.B.B:
18" R.B.B:
24" R.B.B:
30" R.B.B:
TAN SHELF DEPTH:
ROCK POCKETS:
CENTERS:
FILTER:
PLUMBING
SIZE:
POOL PUMP:SIZE:
BOOSTER PUMP:SIZE:
ADD'L PUMP:SIZE:
ADD'L PUMP:SIZE:
HEATER:SIZE:
CONTROL SYSTEM:
SUB PANEL AMP:
ADD'L OUTLETS:
GAS LINE FT:
FOUNTAINS / SPRAYHEADS:
SHEER DESCENTS:
POOL LIGHTS:
PLUMBING:
SPILLWAY TYPE:
GUNITE
SPILLWAY SIZE:
DAM WALL WIDTH:
MISC:
COPING TYPE:
MASONRY
R.B.B. FACE:
REPLACE ACCESS WALL:
SPILLWAY TYPE:
SPILLWAY SIZE:
FIREPIT:
BBQ:
EQUIP. WALLS:
RETAINING WALLS:
PLANTER WALL:
FENCE TYPE:
FENCING
HEIGHT:
REMOVE & REHANG:
GATE TYPE:
PEBBLE COLOR:
PEBBLE / PLASTER
FITTINGS COLOR:
STEP TRIM:
PLASTER COLOR:
UMBRELLA SLEEVE:
EST. START:
EST. COMPLETION:
S C A L E : 1 8 " = 1 '-0 "
SPA FACE:
SPA LIGHTS:
SAND & VISQUEEN:
WATERLINE MATERIAL:
400,000 BTU HEATER. ALL EQUIPMENT SHALL BE
SEISMICALLY ANCHORED. 4'-0" MIN. CLEARANCE
TO OPENING WINDOW
35' - 11 2" POLYPROPYLENE GAS PIPE
3 4" PVC ELECTRIC CONDUIT WITH
#10 AWG WIRE TO SUBPANEL
POOL EQUIPMENT SUBPANEL WITH 36" CLEARANCE
AT FRONT
GUNITE
273 SQ. FT.
80 LN. FT.
28'-0"12'-0"
3'-6"5'-0"
8'-0"6'-0"
48 SQ. FT.
28 LN. FT.
4 HYDROTHERAPY JETS
-0-
N/A
429 SQ. FT.
BROOM
YES
80 LN. FT.
NO
NO
NO
60" BOBCAT
LEFT SIDE YARD
NO
NO
12" WATER DEPTH
NO
AS NECESSARY
PENTAIR
PENTAIR
PENTAIR
520
VARIABLE
SEE SELECTION
30 AMPS
35 LN. FT.
3 - GLOBRITE COLOR LED
1 - GLOBRITE COLOR LED
DAM WALL
15 LN. FT.
10-3/4" WIDE
BROOM FINISH CONCRETE
DAM WALL
PER PLAN
TILE
N/A
N/A
N/A
N/A
N/A
N/A
POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART.
ANTI-COVERS 10" ASME / ANSI APPROVED
ANTI-ENTRAPMENT COVERS TO BE HYDRAULICALLY BALANCED
811 DIG ALERT - BEFORE DIGGING
SUBPANEL SCHEDULE
1
2
3
POOL PUMP
POOL LIGHT
20 AMP
208 1PH
15 AMP
1PH - GFCI
2019 California Residential Code (CRC), is based on the 2018 International Residential Code
2019 California Electrical Code (CEC), based on the 2017 National Electrical Code (NEC)
2019 California Mechanical Code (CMC), based on the 2018 Uniform Mechanical Code (UMC)
2019 California Plumbing Code (CPC), based on the 2018 Uniform Plumbing Code (UPC)
2019 California Green Code (CGC), written by the California Building Standards Commission (CBSC)
2019 California Energy Code (CEC), written by the California Energy Commission (CEC)
SPA SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART.
ANTI-COVERS 10" ASME / ANSI APPROVED
ANTI-ENTRAPMENT COVERS TO BE HYDRAULICALLY BALANCED
1- PENTAIR 420 CARTRIDGE FILTER
1- PENTAIR INTELLIFLO VARIABLE SPEED PUMP
1- PENTAIR MASTERTEMP 400,000 BTU HEATER
1- 30 AMP SUBPANEL
1- 300 WATT POOL LIGHT
1- 100 WATT SPA LIGHT
SPA / HEATER / PUMP SHALL BE INSTALLED
PER MANUFACTORS RECOMMENDATIONS AND
IN ACCORDANCE TO LOCAL REGULATIONS
EQUIPMENT SCHEDULE
*NO OUTDOOR SURROUNDING LIGHTING OR LOW VOLTAGE LIGHTING
*NO OVERHEAD UTILITY / SERVICE LINES
*DECK BONDING - B
NPT GMS-SILVER GEMSTONE SILVER
S E L E C T I O N S
STONE
TILE
CONCRETE
GROUT
CONTROL SYSTEM
INDOOR CONTROL
PEBBLE / PLASTER
PAVERS
NONE
STANDARD GREY
NONE
T.B.S.
SCREENLOGIC INTERFACE
MINI PEBBLE: CARIBBEAN BLUE
MISC:
WD = WATER DEPTH
SB = SET BACK
A B B R E V I A T I O N L E G E N D
S = SKIMMER
A = AUTOFILL
PALM DESERT MUNICIPAL CODE REQUIREMENTS:
APPROVED TEMPORARY SANITARY FACILITIES (i.e. CHEMICAL TOILETS SHALL BE ON THE CONSTRUCTION SITE PRIOR TO REQUEST FOR
FIRST INSPECTION), (HEALTH AND SAFETY CODE, SECTION 5416)
CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS.
(ORDINANCE NO. 262 OF THE PALM DESERT MUNICIPAL CODE)
STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT FOR WHICH THE PERMIT IS ISSUED. ADJACENT VACANT
PROPERTIES MAY NOT BE UTILIZED FOR THIS PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS ON FILE WITH THIS OFFICE.
THE PUBLIC RIGHT-OF-WAY SHALL BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES. (PALM DESERT MUNICIPAL CODE, CHAPTER 8.02)
CONSTRUCTION HOURS:
OCTOBER 1 THRU APRIL 30
MONDAY - FRIDAY 7:00AM - 5:30PM
SATURDAY 8:00AM - 5:00PM
SUNDAY NOT ALLOWED
GOVERNMENT CODE HOLIDAYS
NOT ALLOWED
MAY 1 THRU SEPTEMBER 30
MONDAY - FRIDAY 6:00AM - 7:00PM
SATURDAY 8:00AM - 5:00PM
SUNDAY NOT ALLOWED
GOVERNMENT CODE HOLIDAYS
NOT ALLOWED
VIOLATION OF THE ABOVE WORK HOURS IS A CITABLE OFFENSE UNDER PALM DESERT MUNICIPAL CODE SECTION 9.24.070
STEP TRIM:NO
N/A
TO MATCH
N/A
YES - PER PLAN
N/A
LO
T
4
7
Q
2
@
M
O
N
T
A
G
E
D A T E :05.09.22
AT EXCAVATION
HP = HIGH POINT
STUBS:N/A
EASY TOUCH 4 W/ SALT
2-1 2" SUCTION & 2" RETURN
MISC.
T-24 ENERGY REQUIREMENTS IN PLANS TO INCLUDE BUT NOT LIMITED TO:
a. TIGHT FITTING POOL COVER
b. SUBMIT CF-2R-PLB-03-E AT FINAL INSPECTION
c. CONSTRUCT 36" PIPING BETWEEN HEATER & PUMP FOR FUTURE SOLAR
WATER BONDING AT THIS LOCATION
ACCESS GATES THROUGH THE ENCLOSURE MUST OPEN AWAY
FROM THE SWIMMING POOL, AND MUST BE SELF-CLOSING WITH
A SELF-LATCHING DEVICE
ADDRESS NUMERALS SHALL COMPLY WITH PALM DESERT ORDINANCE 1265 (PDMC 15.28)
(b) ALTERNATE MEANS. EQUIPOTENTIAL BONDING CONDUCTOR MEETING THE FOLLOWING:
1. 8 AWG BARE SOLID COPPER BONDING CONDUCTOR
2. THE BONDING CONDUCTOR SHALL FOLLOW THE CONTOUR OF THE PERIMETER SURFACE.
3. LISTED SPLICING DEVICES
4. BONDING CONDUCTOR SHALL BE 18 TO 24 IN. FROM THE INSIDE WALLS OF THE POOL
5. BONDING CONDUCTOR SHALL BE SECURE WITHIN OR UNDER THE PERIMETER SURFACE
4 TO 6 IN BELOW THE SUBGRADE
METALLIC PARTS OF THE POOL, OUTDOOR SPA, OR OUTDOOR
HOT TUB STRUCTURE SHALL BE BONDED TO THE EQUIPOTENTIAL GRID
UNDERWATER METAL FORMING SHELLS.METAL FORMING SHELLS AND MOUNTING
BRACKETS FOR LUMINAIRES AND SPEAKERS SHALL BE BONDED TO THE EQUIPOTENTIAL GRID
18 TO 24 IN. FROM
INSIDE WALL OF POOL 8 AWG BARE
SOLID COPPER
PERIMETER
SURFACE
EQUIPOTENTIAL BONDING
PERIMETER SURFACE
SECTION 680.26(B)2(b)
AS NECESSARY
X
400,000 BTU
N/A
SEE SELECTIONS
TILE DAM WALL
N/A
N/A
N/A
PROPERTY LINE
EXISTING 6'-0" HIGH BLOCK WALL
UNDER WATER
POOL LIGHT
UNDER WATER SPA LIGHT
SAFETY EXIT
DOOR ALARM
MAIN HOUSE 200 AMP ELECTRICAL PANEL
EXISTING GAS METER
PLAN APPROVED BY:
SALESPERSON:BLAKLEY
GUNITE DAM WALL TO FINISH AT 103 4"
SPA AT -0- WITH TILE DAM WALL
TANNING SHELF AT 12" WATER DEPTH WITH
ONE UMBRELLA SLEEVE
BROOM FINISH CONCRETE STEPPING PADS
BROOM FINISH CONCRETE STEPPING PADS
PROPERTY LINE
EXISTING 6'-0" HIGH BLOCK WALL
PROPERTY LINE
EXISTING 6'-0" HIGH BLOCK WALL
PROPERTY LINE
SAFETY EXIT
DOOR ALARM
SAFETY EXIT
DOOR ALARM