Loading...
HomeMy WebLinkAboutAPPROVED-RRAD22-0164 T24.pdfCERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 1 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 GENERAL INFORMATION 01 Project Name O'Shea Parial Garage Conversion 02 Run Title Compliance 03 Project Location 45876 Abronia Trail 04 City Palm Desert, CA 05 Standards Version 2019 06 Zip code 92260 07 Software Version CBECC-Res 2019.2.0 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal)180 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope AdditionAlteration 13 Number of Bedrooms 3 14 Addition Cond. Floor Area (ft 2)235 15 Number of Stories 1 16 Existing Cond. Floor Area (ft 2)906 17 Fenestration Average U-factor 0.4 18 Total Cond. Floor Area (ft 2)1141 19 Glazing Percentage (%)22.09% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Is Natural Gas Available?Yes COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY Energy Use (kTDV/ft 2-yr)Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 4.93 5.16 -0.23 -4.7 Space Cooling 233.29 215.05 18.24 7.8 IAQ Ventilation 0 0 0 Water Heating 29.48 29.48 0 0 Self Utilization/Flexibility Credit n/a 0 0 n/a Compliance Energy Total 267.7 249.69 18.01 6.7 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 2 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Non-standard duct location (any location other than attic) HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building-level Verifications: •-- None -- Cooling System Verifications: •Verified Refrigerant Charge •Refrigerant Charge verification required if a refrigerant containing component is altered Heating System Verifications: •Verified heat pump rated heating capacity HVAC Distribution System Verifications: •Duct Sealing required if a duct system component, plenum, or air handling unit is altered Domestic Hot Water System Verifications: •-- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft 2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems O'Shea Parial Garage Conversion 1141 1 3 2 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft 2)Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Existing Conditioned HVAC System E 906 8 DHW System ALT N/A Zone 2 Conversion Conditioned HVAC System 2 235 8 DHW System ALT N/A 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 3 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 OPAQUE SURFACES 01 02 03 04 05 06 07 08 09 10 11 Name Zone Construction Azimuth Orientation Gross Area (ft 2)Window and Door Area (ft2) Tilt (deg)Wall Exceptions Status Verified Existing Condition Z1 Front Zone 1 Existing E Walls 180 Front 320 46 90 none Existing No Z1 Left Zone 1 Existing E Walls 270 Left 280 24 90 none Existing No Z1 Rear Zone 1 Existing E Walls 0 Back 320 80.03 90 none Existing No Z1 Right Zone 1 Existing E Walls 90 Right 280 76.02 90 none Existing No Z2 Left Zone 2 Conversion N Walls 270 Left 118 20 90 none New n/a Z2 Rear Zone 2 Conversion N Walls 0 Back 24 6 90 none New n/a Z2 Right Zone 2 Conversion N Walls 90 Right 118 20 90 none New n/a Z2 Front Zone 2 Conversion N Walls 180 Front 184 0 90 none New n/a Interior Wall 1 Zone 2 Conversion>>Zo ne 1 Existing Common n/a n/a 56 0 n/a New n/a OPAQUE SURFACES - CATHEDRAL CEILINGS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Zone Construction Azimuth Orientation Area (ft2) Skylight Area (ft 2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Status Verified Existing Condition Existing Construction Cathedral Ceiling 1 Zone 1 Existing Ceilng E 180 Front 906 0 0.25 0.1 0.85 No Existing No Cathedral Ceiling 2 Zone 2 Conversion N Ceiling 180 Front 235 0 0.25 0.1 0.85 No New n/a 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 4 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading Status Verified Existing Condition Window D Window Z1 Front Front 180 6 2 1 12 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window C Window Z1 Front Front 180 3 3 1 9 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window B Window Z1 Front Front 180 3 3 1 9 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window A Window Z1 Front Front 180 4 4 1 16 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window L Window Z1 Left Left 270 6 2 1 12 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window K Window Z1 Left Left 270 3 2 1 6 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window J Window Z1 Left Left 270 3 2 1 6 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window H Window Z1 Rear Back 0 5 4 1 20 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window G Window Z1 Rear Back 0 3 6.67 1 20.01 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window F Window Z1 Rear Back 0 6 6.67 1 40.02 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window I Window Z1 Right Right 90 6 6.67 1 40.02 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window E Window Z1 Right Right 90 6 6 1 36 0.7 NFRC 0.79 NFRC Bug Screen Existing No Window 1 Window Z2 Left Left 270 4 5 1 20 0.4 NFRC 0.35 NFRC Bug Screen New n/a Window 2 Window Z2 Rear Back 0 2 3 1 6 0.4 NFRC 0.35 NFRC Bug Screen New n/a OPAQUE DOORS 01 02 03 04 05 06 Name Side of Building Area (ft 2)U-factor Status Verified Existing Condition InputDoor 1 Z2 Right 20 0.2 New n/a 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 5 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 SLAB FLOORS 01 02 03 04 05 06 07 08 09 10 Name Zone Area (ft 2)Perimeter (ft) Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Status Verified Existing Condition Slab On Grade 1 Zone 1 Existing 906 150 none 0 80%No Existing No Slab On Grade 2 Zone 2 Conversion 235 75 none 0 80%No New n/a OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers E Walls Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / None 0.101 Inside Finish: Gypsum Board Cavity / Frame: R-13 / 2x4 Exterior Finish: 3 Coat Stucco N Walls Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / None 0.101 Inside Finish: Gypsum Board Cavity / Frame: R-13 / 2x4 Exterior Finish: 3 Coat Stucco Ceilng E Cathedral Ceilings Wood Framed Ceiling 2x12 @ 24 in. O. C.R-19 None / None 0.05 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-19 / 2x12 Inside Finish: Gypsum Board N Ceiling Cathedral Ceilings Wood Framed Ceiling 2x12 @ 24 in. O. C.R-30 None / None 0.034 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-30 / 2x12 Inside Finish: Gypsum Board 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 6 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers Common Interior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-13 None / None 0.092 Inside Finish: Gypsum Board Cavity / Frame: R-13 / 2x4 Other Side Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 Not Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 10 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification Status Verified Existing Condition Existing Water Heating System DHW System ALT Domestic Hot Water (DHW) Standard Distribution System Water Heater 1 (1)n/a None n/a Altered No WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Heating Element Type Tank Type # of Units Tank Vol. (gal) Energy Factor or Efficiency Input Rating or Pilot Tank Insulation R-value (Int/Ext) Standby Loss or Recovery Eff 1st Hr. Rating or Flow Rate NEEA Heat Pump Brand or Model Tank Location or Ambient Condition Status Verified Existing Condition Water Heater 1 Gas Consumer Storage 1 50 0.56-UEF <= 75 kBtu/hr 0 78 80 gal n/a n/a Altered No 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 7 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW System ALT - 1/1 Not Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Required Thermostat Type Status Verified Existing Condition Heating Equipment Count Cooling Equipment Count HVAC System 2 Heat pump heating cooling Heat Pump System 1 Heat Pump System 1 HVAC Fan System 2 Distribution System 2 Setback New No 1 1 HVAC System E Heat pump heating cooling Heat Pump System E Heat Pump System E HVAC Fan System 1 E Distribution System 1 E n/a Existing No 1 1 01 02 03 04 05 06 07 08 09 10 11 HVAC - HEAT PUMPS Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER/CEER Heat Pump System 1 Ductless MiniSplit HP 1 8 14600 14600 18 13 Not Zonal Single Speed Heat Pump System 1-hers-htpump Heat Pump System E Central packaged HP 1 8 48000 48000 12 10.42 Not Zonal Single Speed Heat Pump System E-hers-htpump 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 8 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Verified HSPF Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Not Required 0 Not Required Not Required Yes No Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Duct Ins. R-value Duct Location Surface Area Name Type Design Type Supply Return Supply Return Supply Return Bypass Duct Duct Leakage HERS Verification Status Verified Existing Condition Existing Distribution system New Ducts 40 ft Distributi on System 1 E Ducts located in multiple places Non- Verified R-4.2 R-4.2 Condit ioned Zone Condit ioned Zone n/a n/a No Bypass Duct Existing (not specified) Distributi on System 1 E-hers- dist Existing No n/a n/a Distributi on System 2 No ducts Non- Verified R-0.0 R-0.0 n/a n/a No Bypass Duct Sealed and Tested Distributi on System 2-hers- dist New n/a n/a n/a HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan System 1 E HVAC Fan 0.45 HVAC Fan System 1 E-hers-fan HVAC Fan System 2 HVAC Fan 0.58 HVAC Fan System 2-hers-fan 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 9 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan System 1 E-hers-fan Not Required 0 HVAC Fan System 2-hers-fan Not Required 0 HERS RATER VERIFICATION OF EXISTING CONDITIONS 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc. CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name:O'Shea Parial Garage Conversion Calculation Date/Time:2022-08-31T19:27:08-07:00 (Page 10 of 10) Calculation Description:Compliance Input File Name:O'Shea Parial Garage Conversion.ribd19 Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.2.000 Schema Version: rev 20200901 Report Generated: 2022-08-31   19:27:37 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   Easy to Verify at CalCERTS.com JORGE GARCIA JORGE GARCIA DESIGN ASSOCIATES 45175 PANORAMA DRIVE SUITE E Palm Desert, CA 92260 2022-08-31 19:30:57 N/A 760-272-9222 JORGE GARCIA JORGE GARCIA DESIGN ASSOCIATES 45175 PANORAMA DRIVE SUITE E Palm Desert, CA 92260 2022-08-31 19:30:57 N/A 760-272-9222 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. 222-P010150181E-000-000-0000000-0000 2022-08-31 19:30:57 CalCERTS inc.