HomeMy WebLinkAboutPlansPr o j e c t N a m e Date Drawn: Drawn By: Revision No. Sheet No. 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 0 C1 COVER SHEET VICINITY MAP Riverside County: APN 630360013 SCOPE OF WORK: Project consists of installing a solar photovoltaic (PV) system and battery system comprised of: 24 SPR-M425-H-AC modules, 26-2 kwh Sunvault battery, Hub +, 60A disconnect, conduits w/fittings and wires, roof stanchions, and a rack mounting system to provide a renewable power source for the customer. PROJECT CONTACTS: CONTRACTOR: RENOVA permits@renovaenergy.com Primary Contact: Matthew De La Torre Secondary Contact: Amy Dominguez SHEET INDEX GENERAL C1 COVER SHEET S1 SITE PLAN ELECTRICAL E1 PROJECT SIGNAGE E2 SINGLE LINE DATA SHEET MODULE BATTERY WIND CALCULATION RACKING AC DISCONNECT DAVID THORNBURY 09/29/2022 APPLICABLE CODES: California Residential Code 2019 California Electrical Code 2019 National Electrical Code 2017 2019 California Amendments City of Palm Desert Municipal Code CONSTRUCTION HOURS: OCTOBER 1 THRU APRIL 30 Monday - Friday 7:00 am - 5:30 pm Saturday 8:00 am - 5:00 pm Sunday NOT ALLOWED Government Code Holidays NOT ALLOWED MAY 1 THRU SEPTEMBER 30 Monday - Friday 6:00 am - 7:00 pm Saturday 8:00 am - 5:00 pm Sunday NOT ALLOWED Government Code Holidays NOT ALLOWED RO B E R T D O W L I N G ( C S H 4 6 2 2 3 ) ( E S S 4 6 5 0 5 ) 47 3 2 7 A B D E L C I R C L E PA L M D E S E R T , C A . 9 2 2 6 0 BATTERY SYSTEM SIZE: 26.0 kWh CEC AC SYSTEM SIZE: 13.584 kW AC ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA RESIDENTIAL CODE, 2019 ELECTRICAL CODE BASED ON THE 2017 NATIONAL ELECTRICAL CODE. ABDEL C I R C L E 200 AMP SUNPOWER SUNVAULT HUB+ SV-HUB-01-A 120/240 VOLT LOCATED INSIDE GARAGE D R I V E W A Y NOTES: 1. THIS IS A 10.200 KW SOLAR ELECTRIC SYSTEM USING (24) SUNPOWER SPR-M425-H-AC MODULES (425 WATT). 2. THIS SYSTEM IS GRID-INTERTIED VIA AC MODULES PER NEC 690.6. 3. THIS IS AN AC COUPLED STORAGE SYSTEM WITH BUILT-IN AC/DC INVERTER. STORAGE 26-2 (KWh) SUNPOWER ENERGY SYSTEM WITH SUNPOWER SUNVAULT HUB+. 4. THIS IS A ROOF MOUNTED SYSTEM, ADDING 2.84 LB/SQ FT. ROOF IS FOAM AT 0° PITCH. 5. THE SYSTEMS SQUARE FOOTAGE IS 499 FT² (16% OF TOTAL ROOF AREA). MODULES HAVE AN AZIMUTH OF 165° 6. MODULES ARE 0° TILT ABOVE ROOF SLOPE, NOT TO EXCEED 18" ABOVE ROOF SURFACE. 7. BUILDING IS A SINGLE STORY DWELLING. 8. LAG SCREWS ARE 5/16" X 4" AT 72" O.C. MAX, WITH 2.5" INTO FRAMING. 9. MODULES WILL BE SECURED TO ROOFTOP USING PROSOLAR FASTJACK ATTACHMENTS WITH INVISIMOUNT SUPPORT RAILS. 10. ATTACHMENTS SHALL BE SEALED BY A LICENSED ROOFING CONTRACTOR. 11. DESIGNED FOR BASIC WIND SPEED OF 130 MPH (WIND EXPOSURE C) PER INVISIMOUNT CALCULATIONS, SEE SPECS. 12. VISIBLE EXPOSED CONDUIT SHALL BE PAINTED TO MATCH. 13. MODULE DIMENSIONS ARE 40.6" X 73.7" 14. SYSTEM INSTALLATION SHALL BE PER NEC 690 AND IS SUBJECT TO FIELD INSPECTION BY THE CITY. 15. PROPER CLEARANCES SHALL BE IN ACCORDANCE WITH CAL FIRE GUIDELINES. 16. HEAT ALARM TO BE INTERCONNECTED WITH EXISTING SMOKE ALARM. SOLAR SYSTEM SIZE: 10.200 kW DC CEC AC SYSTEM SIZE: 9.338 kW AC - CIRCUIT #1 - CIRCUIT #2 HEAT DETECTOR #HD135F 120 VOLT AC LOCATED INSIDE GARAGE NEXT TO ESS S I D E Y A R D P R O P E R T Y L I N E - CIRCUIT #3 EXISTING METER #222011-846308 EXISTING 200 AMP MAIN SERVICE PANEL 120/240 VOLT, 1Φ, 3W LOCATED ON SOUTHWEST EXTERIOR WALL STORAGE 26-2 SUNPOWER ENERGY STORAGE SYSTEM #SPWR-M0011 120/240 VOLT LOCATED INSIDE GARAGE 60 AMP AC DISCONNECT SQUARE-D #HU462AWK 600 VOLT; 4 POLE LOCATED NEXT TO MAIN BACK Y A R D PROPER T Y L I N E C O M M O N W A L L P R O P E R T Y L I N E AC SOLAR MODULES VENT 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Sheet No. Revision No. Date Drawn: Drawn By: Pr o j e c t N a m e : Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 0 S1 SITE PLAN DAVID THORNBURY 09/29/2022 RO B E R T D O W L I N G ( C S H 4 6 2 2 3 ) ( E S S 4 6 5 0 5 ) 47 3 2 7 A B D E L C I R C L E PA L M D E S E R T , C A . 9 2 2 6 0 NOTE: RED BACKGROUND WITH WHITE LETTERING 3/8" LETTER HEIGHT PROJECT SIGNAGE NOTES & PANEL SCHEDULE MAIN PANEL: MECHANICALLY ATTACHED WARNING THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. MAIN PANEL (YOU ARE HERE) BATTERY RAPID SHUTDOWN (NEXT TO MAIN) ENERGY STORAGE SYSTEM (GARAGE) SUNVAULT HUB + WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. ENERGY BREAKER WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE. MAIN PANEL THIS PANEL IS FED BY THREE SOURCES: UTILITY, BATTERY & SOLAR PHOTOVOLTAIC AC DISCONNECT RAPID SHUTDOWN SWITCH FOR BATTERY SYSTEM ENERGY BREAKER RAPID SHUTDOWN DISCONNECT 1 OF 2 AC DISCONNECT WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. MAX AC OPERATING CURRENT: 28.3 A OPERATING AC VOLTAGE: 240 Volts MAIN PANEL PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS MARKING 1. THE MATERIAL USED FOR MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. MARKING AS REQUIRED IN SECTIONS R 331.2.2 THROUGH R331.2.4 SHALL HAVE LETTERS CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8" WHITE ON RED BACKGROUND. (CRC R331.2.1) 2. THE MARKING CONTENT SHALL CONTAIN THE WORDS "WARNING; PHOTOVOLTAIC POWER SOURCE" (CRC R331.2.2) SAFEGUARDS 1. SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL. ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE-D & GE. 2. ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED. 3. WILEY CABLE CLIPS SHALL BE USED. 4. ALL EMT SHALL USE OUTDOOR RAINTIGHT COMPRESSION FITTINGS. 5. ALL EQUIPMENT SHALL BE LABELED. 6. ADD COMBINER / JUNCTION BOXES AS NEEDED. 7. AN INTERNAL BLOCKING DIODE IS PROVIDED IN EACH MODULE. 8. MODULE GROUNDING SHALL BE MADE VIA RACKING CLAMPS. 9. ALL NEUTRAL TO GROUND CONNECTIONS SHALL OCCUR IN THE MAIN PANEL. 10. EMT SHALL BE 3/4" MINIMUM. 11. JUNCTION BOX/ COMBINER BOX ENTRY SHALL USE COMPRESSION FITTINGS. NOTES 1. WIRE AND SIZES ARE AS INDICATED OR LARGER. 2. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. 3. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. 4. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. ALL WIRING BETWEEN AC MODULES SHALL BE PV-WIRE AND AC CABLE. ALL CONDUIT SHALL BE 3/4" EMT OR LARGER. ALL CONDUIT SHALL BE BONDED. ALL CONDUIT SHALL BE SUPPORTED BY RUBBER PYRAMID SUPPORTS. STEEL CITY 6"X6"X4" (OR LARGER) OUTDOOR JUNCTION BOXES SHALL BE USED AS NEEDED. ALL CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF CONNECTORS TO PROTECT WIRES. AC DISCONNECT RAPID SHUTDOWN DISCONNECT 2 OF 2 PV RAPID SHUTDOWN (CB INSIDE MAIN) MAIN PANEL PCS CONTROLLED CURRENT SETTING 115A THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY. REFER TO MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. VA LOAD A B TYPE C.B. BUS CO D E N R L TR P CONNECTED VA (CODE L):22800 22.8 95.0 A B 11400 11400 PHASE TOTAL LOAD DESCRIPTION VA LOAD BA TYPEC.B. CO D E NRLTRP LOAD DESCRIPTION PANEL: SUNVAULT HUB+ LOCATION: GARAGE MOUNTING: SURFACE PANEL VOLTAGE: 240/120 V 1Φ,3W BUS: 200A N: NON-CONTINUOUS L: LONG-CONTINUOUS R: DEMANDABLE RECEPTACLES CIRCUIT CODE: CONNECTED VA (CODE R): CONNECTED VA (CODE N): TOTAL CONNECTED KVA: TOTAL PANEL AMPS: PHASE TOTALS A+B (2) 40 x x 6792 6792 STORAGE 26-2 STORAGE 26-2 L L - (2) 40 - 2 - CIRCUIT 1 L 20 x x- 1920 1920 CIRCUIT 1 L 20 - 2 - L L CIRCUIT 2 L 20 x x- 1920 1920 CIRCUIT 2 L 20 - 2 - L L CIRCUIT 3 L 20 x x- 768 768 CIRCUIT 3 L 20 - 2 - L L CO M M O N W A L L PR O P E R T Y L I N E 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Sheet No. Revision No. Date Drawn: Drawn By: Pr o j e c t N a m e : Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 0 E1 PROJECT SIGNAGE DAVID THORNBURY 09/29/2022 RO B E R T D O W L I N G ( C S H 4 6 2 2 3 ) ( E S S 4 6 5 0 5 ) 47 3 2 7 A B D E L C I R C L E PA L M D E S E R T , C A . 9 2 2 6 0 CONDUIT SCHEDULE LOCATION CONDUCTORS CONDUIT 1 (3) #8 THWN-2, (3) #12 THWN-2, (1) #10 EGC 2" EMT 2 (6) #10 THWN-2, (1) #10 EGC 3/4" EMT 3 (3) 1/0 THWN-2, (1) #6 EGC 1-1/2" EMT SINGLE LINE DIAGRAM CALCULATIONS RELOCATE LOADS TO 200 AMP SUNPOWER SUNVAULT HUB+ SV-HUB-01-A 120/240 VOLT LOCATED INSIDE GARAGE BACKUP 200A BUSLOADS LOADS SOLAR ARRAY (24) SUNPOWER 425 WATT PHOTOVOLTAIC MODULES #SPR-M425-H-AC (2 CIRCUITS OF 10 MODULES & 1 CIRCUIT OF 4 MODULES) 20A BATTERY SYSTEM SIZE: 13.0 kWh CEC AC SYSTEM SIZE: 13.584 kW AC SOLAR SYSTEM SIZE: 10.200 kW DC CEC AC SYSTEM SIZE: 9.338 kW AC PVS6 GENERATION 125A BUS 3 15A NON-BACKUP 125A BUS 20A 2 G BAR EXISTING 125A MAIN BREAKER SOLAR BREAKER SUITABLE FOR DISCONNECTING MEANS PER NEC 690.13 125 AMP BREAKER EXISTING GROUNDING ELECTRODE TO UTILITY N BAR *FOR UTILITY PURPOSES ONLY:(24) ENPHASE IQ7HS-66-ACM-US (IQ7HS-66-ACM-US) 240V [SI1] INVERTERS EGC = EQUIPMENT GROUNDING CONDUCTOR, GEC = GROUNDING ELECTRODE CONDUCTOR #6 COPPER SOLID GROUND TO BE USED ON ROOFTOP WHEN NOT PROTECTED BY CONDUIT ALL BREAKERS SHALL BE 2 POLE UNLESS OTHERWISE NOTED ALL INNER-CIRCUIT WIRING SHALL BE #10 THWN-2 WIRE OR GREATER. PCS OF THE SUNVAULT HUB+ WILL LIMIT THE AMOUNT OF BACKFEED CURRENT TO THE MAIN SERVICE PANEL. SETTING MUST NOT BE ACCESSIBLE TO NON-AUTHORIZED INDIVIDUALS. SEE LABEL ON E1 AFCI PROTECTION IS REQUIRED WHEN LOADS ARE RELOCATED MORE THAN 6’ [210.12(D)]. 20A M METER #222011-846308 20A 40A STORAGE 26-2 SUNPOWER ENERGY STORAGE SYSTEM #SPWR-M0011, 120/240 VOLT LOCATED INSIDE GARAGE 1 1 60 AMP AC DISCONNECT SQUARE-D #HU462AWK 600 VOLT; 4 POLE LOCATED NEXT TO MAIN 40A EXISTING 200 AMP MAIN SERVICE PANEL 240/120 VOLT, 2-POLE LOCATED ON SOUTHWEST EXTERIOR WALL SERVICE EQUIPMENT IS TOP FED AC CIRCUITS STORAGE TO SUNVAULT HUB + STORAGE 26-2 = 28.3 AMPS X 1.25 [PER NEC 215.2 (A)1] = 35.4 AMP (EACH INVERTER) = ((2) 40 AMP STORAGE BREAKERS) MAX VOLTAGE AC 240 VOLT. AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE AND A MINIMUM OF 1" ABOVE ROOFTOP SURFACE. #8 WIRE = 55 AMPS X .82[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(A)] = 45.1 AMP ≥ 40 AMP ✓ (3) #8 THWN-2 AWG WIRE, (1) #10 THWN-2 GROUND 2" EMT @ 40% FILL PER NEC TABLE C.1 = (36) #8 THWN-2 WIRES ✓ AC MODULES TO SUNVAULT HUB+ (GENERATION BUS) 2 CIRCUITS X 10 MODULES & 1 CIRCUIT X 4 MODULES = 24 MODULES MAX VOLTAGE AC 240 VOLT 1.60 AMPS EACH CIRCUIT X MAX 10 MODULES X 1.25[PER NEC 690.8] = 20.0 AMPS (20 AMP CB) AC CONDUIT SHALL BE MOUNTED A MINIMUM OF 1" ABOVE ROOFTOP SURFACE. ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 42°C AMBIENT TEMP. PER SOLARABCS.ORG #10 WIRE = 40 AMPS X .82[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(A)] = 32.8 AMPS 32.8 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(3)(a)] = 26.24 AMPS ≥ 20 AMPS ✓ 3 CIRCUITS = (6) #10 THWN-2 AWG WIRE, (1) #10 THWN-2 GROUND 3/4" EMT @ 40% FILL PER NEC TABLE C.1 = (10) #10 THWN-2 WIRES ✓ SUNVAULT HUB + TO MAIN PANEL MAX OUTPUT = (24 MODS X 1.60 AMP + 28.3 x 2 AMPS) X 1.25 [PER NEC 215.2 (A)1] = 118.8 AMPS (125A BREAKER) AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE AND A MINIMUM OF 1" ABOVE ROOFTOP SURFACE. 1/0 WIRE = 170 AMPS X .82[PER NEC TABLE 310.15(B)(16) & PER NEC TABLE 690.31(A)] = 139.4 AMP ≥ 125 AMP ✓ (3) 1/0 THWN-2 AWG WIRE, (1) #6 THWN-2 GROUND 1-1/2" EMT @ 40% FILL PER NEC TABLE C.1 = (4) 1/0 THWN-2 WIRES ✓ MAIN PANEL BACKFEED CALCULATION EXISTING 200 AMP MAIN SERVICE PANEL EXISTING 125 AMP MAIN BREAKER 120% OF 200 AMP BUS: ALLOWABLE BACKFED AMPS [PER NEC 705.12(B)(2)] = 240 AMPS 240 AMP - 125 AMP MAIN BREAKER = 115 TOTAL AMP ALLOWABLE MAX OUTPUT = 24 MODS X 1.60 AMP X 1.25 [PER NEC 215.2 (A)1] = 48.0 AMPS MAX OUTPUT = 48.0 AMPS ≤ 115 AMPS ✓ 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Sheet No. Revision No. Date Drawn: Drawn By: Pr o j e c t N a m e : Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 0 E2 SINGLE LINE DAVID THORNBURY 09/29/2022 RO B E R T D O W L I N G ( C S H 4 6 2 2 3 ) ( E S S 4 6 5 0 5 ) 47 3 2 7 A B D E L C I R C L E PA L M D E S E R T , C A . 9 2 2 6 0 10 " 10 " 10 " CO M M O N W A L L PR O P E R T Y L I N E 6' 4' A A ' B B' 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Sheet No. Revision No. Date Drawn: Drawn By: Pr o j e c t N a m e : Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 0 SCALE: 1"=4'2 SCALE:11"=14' ELEVATION A-A' SCALE: 1"=4'3 *MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE *MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE SCALE: N/A 4 *MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE*MODULES NOT TO EXCEED 18" ABOVE ROOF SURFACE ATTACHMENT DETAIL ELEVATION B-B' P1 PROFILE ELEVATIONS - USE (1) 5/16" x 4" SS LAG SCREWS AT 6' O.C. WITH 2.5" EMBEDMENT INTO WOOD RAFTERS. - RAFTERS ARE 2"x6" AT 2' O.C. - DO NOT INSTALL STANDOFFS OVER WOOD CRICKETS - STANDOFFS ATTACHED TO MAIN ROOF FRAMING. HORIZONTAL DISTANCE BETWEEN ATTACHMENTS NOT TO EXCEED 6 FEET ON CENTER VERTICAL DISTANCE BETWEEN ATTACHMENTS NOT TO EXCEED 4 FEET ON CENTER TOP VIEW DAVID THORNBURY RAFTER 09/29/2022 RO B E R T D O W L I N G ( C S H 4 6 2 2 3 ) ( E S S 4 6 5 0 5 ) 47 3 2 7 A B D E L C I R C L E PA L M D E S E R T , C A . 9 2 2 6 0 Pr o j e c t N a m e Date Drawn: Drawn By: Revision No. Sheet No. 75 - 1 8 1 M e d i t e r r a n e a n A v e . Re n o v a E n e r g y C o r p Pa l m D e s e r t , C A 9 2 2 1 1 (7 6 0 ) 5 6 8 - 3 4 1 3 Co n t r a c t o r ' s L i c e n s e # 9 1 0 8 3 6 0 S2 PLOT PLAN DAVID THORNBURY 09/29/2022 RO B E R T D O W L I N G ( C S H 4 6 2 2 3 ) ( E S S 4 6 5 0 5 ) 47 3 2 7 A B D E L C I R C L E PA L M D E S E R T , C A . 9 2 2 6 0 SunPower® Maxeon® Technology Built specifically for use with the SunPower Equinox® system, the only fully integrated solar solution designed, engineered, and warranted by one company. Highest Power AC Density Available. The patented, solid-copper foundation Maxeon Gen 6 cell is over 5% larger than prior generations, delivering the highest efficiency AC solar panel available.* Highest Lifetime Energy and Savings Designed to deliver 60% more energy over 25 years in real-world conditions like partial shade and high temperatures.1 Best Reliability, Best Warranty With more than 42.6 million and 15 GW modules deployed around the world, SunPower technology is proven to last. That’s why we stand behind our module and microinverter with the industry’s best 25-year Combined Power and Product Warranty. Datasheet 0510 15 20 25 150% 140% 130% 120% 110% 100% 90% 80% 70% 60%25 - y e a r E n e r g y Y i e l d p e r W a t t Years of Operation Up to 60% More Lifetime Energy Conventional Panel M-Series Part of the SunPower Equinox® Solar System • Compatible with mySunPowerTM monitoring • Seamless aesthetics Factory-integrated Microinverter • Highest-power integrated AC module in solar • Engineered and calibrated by SunPower for SunPower AC modules 6. 3 7 i n [1 6 1 . 7 m m ] 6. 5 4 i n [1 6 6 m m ] 5% larger 420-440W Residential AC Module M-Series: M440 | M435 | M430 | M425 | M420 SunPower® Residential AC Module * Based on datasheet review of websites of top 20 manufacturers per Wood Mackenzie US PV Leaderboard Q3 2021. 1 Maxeon 435 W, 22.5% efficient, compared to a Conventional Panel on same-sized arrays (260 W, 16% efficient, approx. 1.6 m²), 7.9% more energy per watt (based on PVSyst pan files for avg. US climate), 0.5%/yr slower degradation rate (Jordan, et. al. “Robust PV Degradation Methodology and Application.”PVSC 2018). 2 Voltage range can be extended beyond nominal if required by the utility. 3 Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. 4 Factory set to IEEE 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. 5 Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25°C). All DC voltage is fully contained within the module. 6 UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors; when installed according to manufacturer’s instructions. 7 Please read the safety and installation instructions for more information regarding load ratings and mounting configurations. See www.sunpower.com/company for more reference information. Specifications included in this datasheet are subject to change without notice. ©2021 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo, SUNPOWER EQUINOX and MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S. MAXEON is a registered trademark of Maxeon Solar Technologies, Ltd. For more information visit www.maxeon.com/legal. AC Electrical Data Inverter Model: Type H (Enphase IQ7HS)@240 VAC @208 VAC Max. Continuous Output Power (VA)384 369 Nom. (L–L) Voltage/Range2 (V)240 / 211–264 208 / 183–229 Max. Continuous Output Current (Arms)1.60 1.77 Max. Units per 20 A (L–L) Branch Circuit3 10 9 CEC Weighted Efficiency 97.0%96.5% Nom. Frequency 60 Hz Extended Frequency Range 47–68 Hz AC Short Circuit Fault Current Over 3 Cycles 4.82 A rms Overvoltage Class AC Port III AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Power Factor (adjustable)0.85 (inductive) / 0.85 (capacitive) DC Power Data SPR-M440- H-AC SPR-M435- H-AC SPR-M430- H-AC SPR-M425- H-AC SPR-M420- H-AC Nom. Power5 (Pnom) W 440 435 430 425 420 Power Tolerance +5/-0% Module Efficiency 22.8%22.5%22.3%22.0%21.7% Temp. Coef. (Power)-0.29%/° C Shade Tolerance Integrated module-level max. power point tracking Tested Operating Conditions Operating Temp.-40° F to +185° F (-40° C to +85° C) Max. Ambient Temp.122° F (50° C) Max. Test Load7 Wind: 125 psf, 6000 Pa, 611 kg/m² back Snow: 187 psf, 9000 Pa, 917 kg/m² front Max. Design Load Wind: 75 psf, 3600 Pa, 367 kg/m² back Snow: 125 psf, 6000 Pa, 611 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 66 Maxeon Gen 6 Front Glass High-transmission tempered glass with anti-reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 48 lbs (21.8 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) Warranties, Certifications, and Compliance Warranties • 25-year limited power warranty • 25-year limited product warranty Certifications and Compliance • UL 1741 / IEEE-1547 • UL 1741 AC Module (Type 2 fire rated) • UL 62109-1 / IEC 62109-2 • FCC Part 15 Class B • ICES-0003 Class B • CAN/CSA-C22.2 NO. 107.1-01 • CA Rule 21 (UL 1741 SA)4 (includes Volt/Var and Reactive Power Priority) • UL Listed PV Rapid Shutdown Equipment6 Enables installation in accordance with: • NEC 690.6 (AC module) • NEC 690.12 Rapid Shutdown (inside and outside the array) • NEC 690.15 AC Connectors, 690.33(A)–(E)(1) When used with AC module Q Cables and accessories (UL 6703 and UL 2238)6 : • Rated for load break disconnect PID Test 1000 V: IEC 62804 Packaging Configuration Modules per pallet 25 Packaging box dimensions 1915 * 1072 * 1220 mm Pallet gross weight 590 kg Pallets per container 32 Net weight per container 18,880 kg 1-800-SUNPOWER | sunpower.com 539973 Rev B / LTR_EN Publication Date: October 2021 Please read the safety and installation instructions for details. SunPower Corporation proprietary information. This document is electronically controlled. The latest revision is available in the document management system. All printed copies are not controlled and may be outdated unless marked with a red ink “Controlled Copy” stamp. Title: Tech Note - SunVault™ Completion of Large-Scale Fire Testing (UL 9540A), 540838 RevA Date: 07/06/2021 Page 1 of 4 Form: 001-51499 Rev I Technical Notification Title SunVault™ Completion of Large-Scale Fire Testing (UL 9540A), 540838 RevA Date July 06, 2021 Authors Craig Walker, Principal Battery Engineer Application SunVault™ systems 1.0 Overview SunPower® SunVault™ energy storage system (ESS) units have completed large-scale fire testing as per UL 9540A Edition 4 2019. The testing results qualify SunVault ESS units for exceptions from certain installation requirements in fire code compliance beginning July 1, 2021 in California and in other jurisdictions. This Tech Note explains the SunVault ESS energy ratings, provides the test background information, and references fire code requirements where these UL 9540A test results should be considered for an exemption or an exception. 2.0 SunVault ESS and Aggregate Energy Ratings SunVault Model Number Description Rated Energy SV-BASE13-12-A Base ESS unit 13 kWh SV-ENERGY13-12-A Energy expansion ESS unit 13 kWh 2.1 Base and Energy Expansion Systems The base SunPower SunVault installation consists of one SV-BASE13-12-A ESS unit rated at 13 kWh (paired with one SunVault Hub+). Additional 13 kWh ESS units (SV-ENERGY13-12-A) can be added to increase the aggregate energy of the SunVault installation in 13 kWh increments. For example, a SunVault installation that combines the 13 kWh SV- BASE13-12-A ESS unit with a 13 kWh SV-ENERGY13-12-A ESS energy expansion unit would have an aggregate energy rating of 26 kWh. SunPower Corporation proprietary information. This document is electronically controlled. The latest revision is available in the document management system. All printed copies are not controlled and may be outdated unless marked with a red ink “Controlled Copy” stamp. Title: Tech Note - SunVault™ Completion of Large-Scale Fire Testing (UL 9540A), 540838 RevA Date: 07/06/2021 Page 2 of 4 Form: 001-51499 Rev I Technical Notification In a given installation, combining 13 kWh SV-BASE13-12-A ESS units with 13 kWh SV-ENERGY13-12-A units provides the ability to expand both the power and the energy of that particular system. Where the local fire code prescribes a maximum energy rating requirement for individual ESS units and for aggregate energy in a specific indoor or outdoor installation location, the SunVault individual ESS rating is 13 kWh and the aggregate energy rating is a multiple of 13 kWh which expands incrementally depending on the quantity of ESS units in the system, and does not exceed 104 kWh. 3.0 SunVault UL 9540A Standard Compliance The large-scale fire testing was conducted and reported by UL in accordance with UL 9540A Edition 4 2019, at their fire testing laboratory in Northbrook, IL. The testing and reporting were completed under UL Project #4789520191.8 (see Section 4.6 of this Tech Note). UL designed the test setup and data collection so that the results could be judged against the UL 9540A unit-level performance criteria for both indoor and outdoor wall-mounted residential ESS units. The SunVault test setup comprised three individual ESS units which represented all SunVault ESS models and which were wall mounted with 6″ (152 mm) separation distance between each unit. The center unit contained a battery module with heaters installed on a centrally located cell. This cell was externally heated at a rate of 4–7°C/minute until the cell exhibited a condition called thermal runaway. The test instrumentation recorded the effects of the resulting thermal event in accordance with UL 9540A data collection requirements. Note: UL 9540A test setup requirements prevented testing both wall-mounted and floor-mounted systems in a single test. Wall-mounted systems are considered to be worst case with respect to complying with the UL 9540A performance criteria, and for this reason we believe the test results from the report can be applied to floor- mounted ESS units as well. 4.0 Application to Fire Code Requirements SunVault systems must be installed according to applicable sections of the effective local fire code. Fire codes and fire code sections referenced in this document are intended to inform about requirements which may be excepted or addressed by the large-scale fire testing results. The inclusion of fire codes or fire code sections in this Tech Note does not necessarily imply applicability to all or to any SunVault installations. 4.1 ESS Spacing Exceptions UL determined that a thermal event initiated in one SunVault ESS unit did not propagate to the adjacent ESS units when the units were installed with 6″ (152 mm) of separation on either side of the initiating ESS unit (see pg. 4 of the report). The initiated thermal event was contained within the initiating battery module inside the initiating ESS unit, and no flaming was observed during the test (pg. 4). These results qualify SunVault ESS units for exception from the prescribed 36″ (914 mm) ESS spacing requirements that are part of many local fire codes. The exception permits SunVault installation with 6″ (152 mm) minimum separation distance between ESS units. Code references: • NFPA 1 (2018) 52.3.2.3.5 • NFPA 855 (2020) 15.5, 4.1.5 • IFC (2018)1206.2.8.3 • IFC (2021) 1207.11.2.1 • CFC (July 2021 Supplement) 1206.11.2.1, 1206.1.5 SunPower Corporation proprietary information. This document is electronically controlled. The latest revision is available in the document management system. All printed copies are not controlled and may be outdated unless marked with a red ink “Controlled Copy” stamp. Title: Tech Note - SunVault™ Completion of Large-Scale Fire Testing (UL 9540A), 540838 RevA Date: 07/06/2021 Page 3 of 4 Form: 001-51499 Rev I Technical Notification 4.2 Non-Combustible Construction UL determined that SunVault complies with the UL 9540A performance criterion for installation in locations with combustible constructions (pg. 5). This performance criterion requires that wall surface temperatures do not rise to greater than 97°C (174.6°F) above ambient. The maximum wall surface temperature rise achieved during SunVault UL 9540A testing was just 54°C (97.2°F) above ambient (pg. 22). The test result was achieved with the ESS units installed on black-painted plywood which is combustible and can exhibit a faster temperature rise when compared to gypsum. Consider SunVault’s compliance with the UL 9540A performance criterion for installation on combustible construction when evaluation construction requirements for ESS installation areas. Code references: • NFPA 855 (2020) 15.6.1(1) • CFC (July 2021 Supplement) 1206.11.3.4 4.3 Separation from Doors, Windows, and Means of Egress for Outdoor Installations The UL 9540A testing shows that a thermal event involving the system will not adversely impact occupant egress paths from doors or windows which are located at least 6″ from the edges of an ESS unit. Wall temperature was measured at 6″ intervals along a vertical line offset 6″ from the edge of the initiating ESS unit. The maximum temperature measured at each interval along this line was 10°C (18°F) above ambient (pg. 22). The maximum surface temperature of an adjacent ESS unit located 6″ from the initiating ESS unit was 9°C (16.2°F) above ambient (pg. 22). Additionally, no flaming or explosion hazards were observed. These observations show that occupant egress would not be affected from doors or windows located 6″ (152 mm) from the edge of an ESS. Code references: • NFPA 1 (2018) 52.3.2.1.4.5.2 • NFPA 855 (2020) 15.6.1(3) • IFC (2021) 1207.11.3.3 • IFC (2018) 1206.2.8.7.2 • CFC (July 2021 amendment) 1206.11.3(3) 4.4 Fire Suppression SunVault achieved the UL 9540A unit-level performance criteria for indoor wall-mounted ESS systems without the use of fire suppression. No flaming or explosion hazards were observed during the test. Automatic sprinkler systems or other methods of automatic fire suppression are not required for SunVault to comply with the UL 9540A unit-level performance criteria. Code reference: • NFPA 1 (2018) 52.3.2.7 4.5 Ventilation and Minimum Room Size SunVault ESS feature batteries of the lithium-ion variety and which do not produce flammable or toxic gas during charging, discharging, or normal use conditions. Lithium-ion batteries are not required to comply with ventilation or minimum room size requirements in the fire codes. Ventilation and minimum room size requirements in the fire codes do not apply to SunVault ESS. SunPower Corporation proprietary information. This document is electronically controlled. The latest revision is available in the document management system. All printed copies are not controlled and may be outdated unless marked with a red ink “Controlled Copy” stamp. Title: Tech Note - SunVault™ Completion of Large-Scale Fire Testing (UL 9540A), 540838 RevA Date: 07/06/2021 Page 4 of 4 Form: 001-51499 Rev I Technical Notification Code references: • NFPA 1 (2018) 52.3.2.8, 52.3.2.11 • NFPA 855 (2020) 15.11, 15.12 • IFC (2021) 1207.6 • IFC (2018) 1206.2.11.3, 1206.2.12 • CFC (July 2021 Supplement) 1206.11.8, 1206.11.9 Note: Always install SunVault systems according to the effective local fire code. Fire codes referenced in this Tech Note are provided to inform about requirements which may be excepted or addressed by the large-scale fire testing results. Inclusion of fire codes in this document does not necessarily imply applicability to all or to any SunVault installations. 4.6 UL 9540A Test Report Cover Page If you have any questions or would like to request additional information please contact SunPower regulatory compliance engineer Mark McMurtrey at mark.mcmurtrey@sunpowercorp.com. Thank you for helping us change the way our world is powered. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 5 GFT-OP-11a (22-August-2019) Verification of Conformity Verification Number: 104395807CRT-001-VOC Applicant Name & Address: SunPower Corporation 1414 Harbour Way South Suite 1901 Richmond, CA 94804-3694 USA Product Description: Panelboard Ratings & Principle Characteristics: See Amendment 1 Models/Type References: SV-HUB-01-C, SV-HUB-01-B (It is paired with SunPower ESS (SV-BASE13-12-A OR SV-BASE13-12-B OR EQS- BASE13-11-A, Optional: SV-Energy13-12-A, SV-Energy13-12-B) Brand Names: SUNPOWER Specification<s>/Standards: Inverters, Converters, Controllers And Interconnection System Equipment For Use With Distributed Energy Resources [UL 1741:2010 Ed.2(Supplement A) + R:15Feb2018] Power Control Systems (PCS) Certification Requirement Decision 3/8/2019 Verification Issuing Office Name & Address: Intertek Testing Services NA, Inc., 3933 US Route 11, Cortland, NY 13045 USA Date of Tests: 2/1/2022 to 2/10/2022, 4/21/2022 to 5/10/2022 Test Report Number(s): 104106139CRT-001 Signature Name: Dishant Patel Position: Project Engineer Date: 8 March 2022 On the basis of the tests undertaken, the sample of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out. This verification is part of the full test report and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 5 GFT-OP-11a (22-August-2019) Amendment 1  Hub+ Nameplate For Model # SV-HUB-01-C For Model # SV-HUB-01-B  PCS Ratings Operating Mode Import Only (Regular “import Only” mode testing was covered, but only with Zero export control and no control on import limit) Maximum PCS controlled current 80A, 100A, 120A, 140A, 160A and 166A max Average Open-loop Response time 1.83 Sec Maximum Open-loop Response time 2.45 Sec This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 5 GFT-OP-11a (22-August-2019)  Test List UL 1741 CRD Clause No. Test description Verdict 203.5 Step change in load test Pass 203.6 Step Change in Generation Test Pass 204.4 Export limiting from Energy Storage Systems Pass 205.5 Startup / Self Check Abnormal Tests Pass 205.7 Operating Abnormal Tests Pass  PCS Marking Following marking are applied on Hub+. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 4 of 5 GFT-OP-11a (22-August-2019)  PCS Manual Hub+ instruction manual was provided with PCS information as required. it provides instruction on how to configure PCS. Also, a single line diagram and all the compatible Current Transformers and meters are included in the manual. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 5 of 5 GFT-OP-11a (22-August-2019)  Revision Summary Date / project#site Engineer Description 26-May-2022/ G105027239CRT Dishant Patel Updated Model/Type References on Page 1 From ” SV-HUB-01-C (It is paired with SunPower ESS (SV- Base13-12-A OR SV-Base13-12-B, Optional: SV- Energy13-12-A, SV-Energy13-12-B)” To ” SV-HUB-01- C, SV-HUB-01-B (It is paired with SunPower ESS (SV- Base13-12-A OR SV-Base13-12-B OR EQS-BASE13-11-A, Optional: SV-Energy13-12-A, SV-Energy13-12-B)” Added Date of test 4/21/2022 to 5/10/2022 on Page 1. Added SV-HUB-01-B nameplate on Page 2. Updated Average Open-loop response time from ”0.054 sec” to ”1.83 sec”. END sunpower.com Datasheet Configurations and Specifications SunVault System Configuration 13-1 26-1 26-2 52-2 Included Component Model Numbers⁹ • One Hub+ • One SV-BASE13-12-B • One Hub+ • One SV-BASE13-12-B • One SV-ENERGY13-12-B • One Hub+ • Two SV-BASE13-12-B • One Hub+ • Two SV-BASE13-12-B • Two SV-ENERGY13-12-B DC Rated Energy 13 kWh (128 Ah) 26 kWh 26 kWh 52 kWh Max. Usable Energy (DC)1 12 kWh (118 Ah) 24 kWh 24 kWh 48 kWh Max. AC Continuous Backup Output Current 28.3 A continuous 56.6 A continuous Max. AC Output Fault Current 35.0 A 70.0 A AC Overcurrent Protection Device One 40 A / two pole Two 40 A / two pole Rated Single-Phase Load Supported (120 V) 4.8 kW (up to 5 minutes) 9.6 kW (up to 5 minutes) Rated Continuous Charge Power (grid tied and backup) 6.4 kW 12.8 kW Rated Continuous Discharge Power (grid tied) 6.0 kW 12.0 kW Rated Continuous Discharge Power (backup) 6.8 kW 13.6 kW Rated AC Continuous Output Current (grid tied) 25.0 A 50.0 A Load Start Capability (LRA) 43 A 52 A 86 A 104 A Rated Backup Discharge Power (kW)5 30 minutes 7.5 8.0 15.0 16.0 10 second 8.5 12.0 17.0 24.0 1 second 10.0 12.0 20.0 24.0 1 Some energy reserved for internal consumption. 2 Tested at 6 kW, 25°C conditions. 3 SunVault Hub+ rating is 200 A. 4 208 VAC is not supported at this time. 5 Values are rated at 25°C ambient. 6 Extended exposure reduces battery performance. 7 Two enclosures for 26 kWh; four for 52 kWh. 8 Additional hardware details in installation guide 9 SV-BASE13-12-B ships as a BASE and may be converted in the field to a BASE X. Hub+ SV-HUB-01-C accommodates single- and dual-inverter systems; SV-HUB-01-B accommodates single-inverter systems only. Some parameters can vary depending on site-specific conditions. See the SunVault Installation Guide 536685 for guidelines. See www.sunpower.com/facts for additional reference information. Specifications included in this datasheet are subject to change without notice. © 2022 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and SUNVAULT are trademarks or registered trademarks of SunPower Corporation in the U.S. and other countries as well. 1-800-SUNPOWER. 536812 RevE BA S E BA S E Hu b + BA S E X EN E R G Y BA S E Hu b + BA S E X EN E R G Y EN E R G Y BA S E Hu b + Hu b + sunpower.com Datasheet SunPower® SunVault™ Hub+™ Electrical Model Numbers SV-HUB-01-A, SV-HUB-01-B Applications Self-supply, backup, and cost savings Special Features 12 V jumpstart: YES / Generator control: YES / Rapid Power Off: YES Supported Backup Configurations • Whole home (up to 200 A service) • Partial home (up to 400 A service) Max. Allowed Service / Disconnect Rating 200 A Nom. Allowed Service Voltage 120 / 240 V 60 Hz, split phase Short Circuit Rating1 10 kA / 22 kA2 Overcurrent Protection Device Allowed3 100–200 A / service entrance rated AC Metering Solar meter: ANSI C12.20, < 0.5% RGM | Site meter: < 2% Connectivity Ethernet, WiFi, and cellular Backup Transition Seamless Load / Generation Breakers4 Refer to installation guide for available spaces Overvoltage Category OV IV Pollution Degree III Protection Class I Scalability5 Supports multiple storage and PV array systems in parallel 1 Higher short circuit rating is compatible with external suitable rated equipment. 2 With external J-Class fuse or CSR breaker. See the SunVault Installation Guide for guidelines. 3 Recommended service-rated circuit breaker type must be installed. 4 See the SunVault Installation Guide for guidelines. 5 See the SunVault Installation Guide for guidelines. Refer to www.sunpower.com/facts for additional reference information. For more details, see extended datasheet www.sunpower.com/datasheets. Specifications included in this datasheet are subject to change without notice. ©2021 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, SUNVAULT, and Hub+ are trademarks or registered trademarks of SunPower Corporation in the U.S. and other countries as well. 1-800-SUNPOWER. Environmental Ambient Operating Temp. −4°F to 122°F (−20°C to 50°C) Shelf Ambient Temp. −22°F to 140°F (−30°C to 60°C) Humidity 0–95%, condensing Enclosure Type / Ingress Rating NEMA Type 3R / IP54 Max. Elevation 6560 ft (2000 m) Environment Indoor / Outdoor Mechanical Dimensions 17 w × 46 h × 6 in. d (43 × 117 × 15 cm) Weight 80 lb (36 kg) Mounting Options Indoor / Outdoor Conduit Entry Multiple; up to 3 in. Warranties, Certifications, and Compliance Warranty 10 years Certifications and Compliance • ANSI C12.20 (Class 0.5) • CSA C22.2 No. 107.1 • FCC Part 15 Subclass B • UL 67 • UL 869A • UL 1741 536813 RevB sunpower.com Datasheet SunPower® SunVault™ Energy Storage System (ESS) Performance SunVault Base SunVault Energy Expansion Model Number SV-BASE13-12-B SV-ENERGY13-12-B DC Rated Energy 13 kWh (128 Ah) Max. Usable Energy (DC)1 12 kWh (118 Ah) Battery Cell Chemistry Lithium iron phosphate (LiFePO4) Nom. Internal Battery Voltage 51.2 V CEC Weighted RTE Efficiency2 > 86% Individual DC Breaker Rating 125 A / two pole3 Max. AC Continuous Backup Output Current 28.3 A continuous Nom. AC Voltage (L–N–L) 120 / 240 VAC 60 Hz, split phase4 Max. AC Output Fault Current 35 A Max. Short Circuit Rating 10 kA AC Overcurrent Protection Device 40 A / two pole Max. Single-Phase Load Supported (120 V) 4.8 kW (up to 5 minutes) Power Factor (full-rated power) ± 0.85 Rated Continuous Charge Power (Grid tied & Backup) 6.4 kW Rated Continuous Discharge Power (Grid tied) 6.0 kW Rated AC Continuous Output Current (Grid tied) 25.0 A Rated Backup Discharge Power Continuous 6.8 kW Environmental Seismic Rating IEEE 693-2005, AC-156 Environmental Rating Indoor and outdoor rated Acoustic Noise Level < 50 dBA @ 1 m distance, 86°F (30°C) Recommended Operating Temp. 32°F to 86°F (0°C to 30°C) Ambient Operating Temp.6 14°F to 122°F (−10°C to 50°C) Shelf Ambient Temp. −4°F to 113°F (−20°C to 45°C) Initial Energy Reserve 30% Humidity 0–95% (non-condensing) Enclosure Type / Ingress Rating NEMA Type 3R / IP54 Max. Elevation 6560 ft (2000 m) Warranties, Certifications, and Compliance Warranty 10 years Certifications and Compliance • IFCC Part 15 Subclass B • IEEE 1547 • UL 1973 (UL 1642) • UL 1741 • UL 1741 SA (CA Rule 21) • UL 9540 • UL 9540A • UN 38.3 Mechanical User Interface Mobile app, LED panel Dimensions 64.5 h × 26 w × 14.8 in. d (164 × 66 × 38 cm)7 Weight • SV-BASE13: 270 lb (122.5 kg) w/inverter; 528 lb (239.5 kg) fully assembled • SV-ENERGY13: 400 lb (181.4 kg) fully assembled Mounting Options Wall or floor8 sunpower.com Datasheet Energy Storage System: Battery Performance Model SPWR-M0011 Rated Energy 6.5 kWh (128 Ah) Max. Usable Energy 6.0 kWh (118 Ah) Nom. Internal Battery Voltage 51.2 V Max. DC Continuous Output Current 96 A Short Circuit Rating 10 kA Overcurrent Protection Device 125 A / two pole Max. Continuous Power (charge / discharge) 3.5 kW / 4.5 kW Peak Surge Power (discharge; 1 sec.) 5 kW Round-Trip Efficiency @ 25°C 96% Overvoltage Category II Pollution Degree III Protection Class I See www.sunpower.com/facts for more reference information. For more details, see extended datasheet www.sunpower.com/datasheets Specifications included in this datasheet are subject to change without notice. © 2020 SunPower Corporation. All Rights Reserved. SUNPOWER and the SUNPOWER logo are registered trademarks of SunPower Corporation in the U.S. and other countries as well. 1-800-SUNPOWER. 534640 RevB Warranties, Certifications, and Compliance Warranty 10 years Certifications and Compliance • FCC Part 15 Subclass B • UL 1642 • UL 1973 • UN 38.3 Environmental Seismic Rating IEEE 693-2005 Environmental Rating Indoor rated Recommended Operating Temp. 32°F to 86°F (0°C to 30°C) Ambient Operating Temp. 14°F to 113°F (−10°C to 45°C) Storage Ambient Temp. • 7 days: −22°F to 140°F (−30°C to 60°C) • 6 months: −4°F to 113°F (−20°C to 45°C) Humidity 0–95% Enclosure Type / Ingress Rating NEMA 3R / IP55 Elevation 6560 ft (2000 m) Mechanical Dimensions 29.5 in. h × 19 w × 5.3 d (74.5 cm h × 47.5 w × 13.3 d) Weight 128 lb (58 kg) Mounting Options Wall mount Document #524734 Rev D, Vol. 2 1 SunPower Proprietary InvisiMount Span Tables Engineering Summary Letter Volume: 2 ASCE 7 Version: 7-16 Module Type: E/X Series (96-cell) Roof Attachment: Pegasus Tile Roof - Generation 1 The following tables list the allowable spacing of attachment points for the SunPower InvisiMount mounting system. The following building codes and standards were used in the calculations: • California Building Code (CBC 2019) • California Residential Code (CRC 2019) • Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) List of Volumes: 1. E/X Series Module + Pegasus Composite Shingle Attachment 2. E/X Series Module + Pegasus Gen1 Tile Attachment 3. E/X Series Module + Pegasus Gen2 Tile Attachment 4. A Series Module + Pegasus Composite Shingle Attachment 5. A Series Module + Pegasus Gen1 Tile Attachment 6. A Series Module + Pegasus Gen2 Tile Attachment Loads on the system were calculated in accordance with ASCE 7-16, using the following parameters: • Risk Category II • System weight (including PV modules and rails) = 2.50 psf • Module orientations: Portrait & Landscape • No live load acts on top of the PV modules • Wind speed & exposure as indicated in the tables • Roof height and slope as indicated in the tables • Gable and Hip roofs only with modules not in the overhang sections of the roof • For wind load, topographic factor Kzt = 1.0, and directionality factor Kd = 0.85 per ASCE 7-16 Table 26.6-1 • Wind load coefficients per either wind tunnel testing or ASCE 7-16 Chapter 30 (see notes below tables) • Ground snow load as indicated in the tables • For snow loads, thermal factor Ct = 1.2 (“unheated and open air structures”), per ASCE 7-16 Table 7.3-2 • For snow loads, exposure factor Ce = 0.9 (“fully exposed”), per ASCE 7-16 Table 7.3-1 • For snow loads, slope factor Cs is determined per ASCE 7-16 Figure 7-2 assuming the array is an “unobstructed slippery surface” where snow is free to slide off the array • Seismic short-term spectral acceleration (Ss) = 3.73g, maximum, and seismic site class = D, per ASCE 7-16 Section 11.4.2 • Seismic component importance factor Ip = 1.0 per ASCE 7-16 Section 13.1.3; seismic component response factor Rp = 1.5, and component amplification factor ap = 1.0, per ASCE 7-16 Table 13.5-1 and 13.6-1; seismic loads are calculated per ASCE 7-16 Chapters 11 and 13 • Load combinations per CBC Section 1605.2 Document #524734 Rev D, Vol. 2 2 SunPower Proprietary The maximum allowable spans shown in the tables are based on the calculated loads and the capacity of the rail and the attachment, determined by analysis and testing in accordance with CBC 2019 and referenced standards. • Bending strength of aluminum rails is calculated according to the Aluminum Design Manual 2015 Section B.3.2.1 (LRFD) • The strength of the roof attachment hardware is based on product information from the attachment manufacturer • The strength of the lag screw in withdrawal and shear is calculated according to the National Design Specification (NDS) for Wood Construction, 2018 • The maximum allowable attachment spacing is calculated by checking the demand/capacity ratios for bending in the rail and tension, compression and shear on attachments for all required load combinations. The reported maximum allowable spacing is the greatest spacing, rounded down to the nearest rafter spacing increment, for which the demand/capacity ratios are less than or equal to 1.0. • These tables do not consider the strength of the supporting roof structure. In areas of low snow load, the weight of the array is often considered to offset the design live load of the roof, since personnel and equipment cannot be placed on top of the array. It is recommended to stagger attachment points, as shown in Figure 1, to evenly distribute loads to the rafters. Figure 1 • These tables assume that each module is installed centered over a pair of rails, as shown in Figure 2(a). In cases where one rail is closer to the midpoint of the module, as shown in Figure 2(b), adjustments to the spacing may be required. Figure 2 'HVLJQ1DPH 1DPH 6XUQDPH2ZHQ .HQQHWK .HQQHWK0LFKDHO 7RUFKOLJKW/DQH3DOP6SULQJV&DOLIRUQLD8QLWHG6WDWHV)XOO$GGUHVV 7RWDO1XPEHURI3DQHOV 7RWDO1XPEHU2I$WWDFKPHQWV 7RWDO1XPEHURI5DLOV 7RWDO1XPEHURI6SOLFHV 7RWDO1XPEHURI0LG&ODPSV    7RWDO1XPEHURI(QG&ODPSV 7RWDO1XPEHURI:LUH&OLSV 7RWDO1XPEHURI5DLO*URXQGLQJ.LWV    5RRI  5RRI6ORSH *URXQG6QRZ/RDGpg IW $WWDFKPHQW7\SH 7RSRJUDSKLF)DFWRUKzt 4XLFN+RRN.LW´EDVHFXUYHGDQGIODWWLOH 4XLFN0RXQW 40+66 3DQHO2ULHQWDWLRQ PSK & 5DIWHU6SDFLQJ 3DQHO0RGHO 8VHULQSXW 5DLO'LUHFWLRQ 3DUDOOHOWRULGJH IW J 0HDQ5RRI+HLJKWh %XLOGLQJ/HDVW+RUL]RQWDO'LPHQVLRQwidthbldg 3RUWUDLW %DVLF:LQG6SHHGV FHOO LQ  SVI 6HLVPLF3DUDPHWHUSs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pg IW $WWDFKPHQW7\SH 7RSRJUDSKLF)DFWRUKzt 4XLFN+RRN.LW´EDVHFXUYHGDQGIODWWLOH 4XLFN0RXQW 40+66 3DQHO2ULHQWDWLRQ PSK & 5DIWHU6SDFLQJ 3DQHO0RGHO 8VHULQSXW 5DLO'LUHFWLRQ 3DUDOOHOWRULGJH IW J 0HDQ5RRI+HLJKWh %XLOGLQJ/HDVW+RUL]RQWDO'LPHQVLRQwidthbldg 3RUWUDLW %DVLF:LQG6SHHGV FHOO LQ  SVI 6HLVPLF3DUDPHWHUSs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unPower® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates even module spacing • Simple, pre-drilled rail splice • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs • Design in landscape and portrait • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics ȏ 3UHPLXPORZSURȴOHGHVLJQ • Black anodized components • Hidden mid clamps and end clamps  KDUGZDUHDQGFDSSHGȵXVKUDLOV Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • Combine with SunPower modules and monitoring app sunpower.com Elegant Simplicity SunPower® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster LQVWDOODWLRQWLPHGHVLJQȵH[LELOLW\DQGVXSHULRUDHVWKHWLFV 7KHΖQYLVL0RXQWSURGXFWZDVVSHFLȴFDOO\HQYLVLRQHGDQG engineered to pair with SunPower modules. The resulting system-level approach will amplify the aesthetic and LQVWDOODWLRQEHQHȴWVIRUERWKKRPHRZQHUVDQGLQVWDOOHUV SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug)106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Roof Attachment Hardware Supported by InvisiMount System Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal Interface for Other Roof Attachments InvisiMount Operating Conditions Temperature ȫr&WRr& ȫr)WRr) Max. Load 2400 Pa uplift 5400 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation ΖQYLVL0RXQW:DUUDQWLHV$QG&HUWLȴFDWLRQV Warranties 25-year product warranty \HDUȴQLVKZDUUDQW\ &HUWLȴFDWLRQV UL 2703 Listed &ODVV$ȴUHUDWLQJZKHQGLVWDQFHEHWZHHQ roof surface and bottom of SunPower PRGXOHIUDPHLVȱȋ *Module frame that is compatible with the InvisiMount system required for hardware interoperability. © 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. 6SHFLȴFDWLRQVLQFOXGHGLQWKLVGDWDVKHHWDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH InvisiMount Component Images Module* / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap Module* / End Clamp and Rail sunpower.com Document #509506 Rev B (805) 486-4700 (805) 486-4799–fax 1551 S. Rose Ave. Oxnard, CA 93033 View more info on our website at: www.prosolar.com Email us for more information prosolar@prosolar.com FastJack® FJ-300-18 For Oatey® style flashings FastJack® FJ-450-18 For standard height flashings 3" High Part# FJ-300-18 For low profile installations using Oatey® flashings (for composition shingle roof-tops) 4-1/2" High Part# FJ-450-18 For installations using standard flashings (for composition & flat rooftops) 6" High Part# FJ-600-18 For standard flashings (for flat tile rooftops) 7-1/2" High Part# FJ-750-18 For standard flashings (sized for S-curve tile roofs and/or double flashed installations) The Fast Jack® design is covered under Pat. #6,360,491 USED FOR MOUNTING: • Photovoltaic Solar Panels • Solar Thermal Panels • Communication Equipment • Virtually anything needing structural attachment to a roof! Laboratory Tested 2,359 lbs Vertical Pullout! 808 lbs Side Axial Pullout!* Benefits of the FastJack® • Removable post makes installation on existing roofs/retrofit quick and easy (refer to the illustration to the right) • Patented design locates the lag bolt directly under the stanchion providing superior strength values • Fast & easy to install - saves time and labor costs • Precision machined from extruded aluminum, there are no welds to corrode or break • Significantly lighter than steel for installer convenience and reduced shipping costs. • Integrated drill guide insures perfect pilot holes every time - minimizes the possibility of splitting roof rafters • Base design allows virtually any roof flashing to install flat on the roof deck Serrated base grips the roof deck to prevent the base from moving while installing the lag bolt Commercial FastJack® also available (rated at 4,250 lbs.) Flashable Roof Stanchion The patented design of the FastJack® can be easily expressed as the most innovative, efficient and cost-effective tool of it's kind! Between the precision CNC machined base and stanchion along with strict engineering and material standards, the FastJack® has been laboratory tested to provide 2,359 pounds of strength using only a single lag bolt (included)! Four Sizes Available! *Using 1ea. 5/16" x 3-1/2" Lag Bolt RAF T E R Easy installation of flashings on existing roof-tops See reverse for installation theory Standard & Oatey® Flashings slip over the base and under the delicate shingle The post can be installed through the top of the flashing © Professional Solar Products, Inc. March 2006. FASTJACK_layout3.indd 1FASTJACK_layout3.indd 1 4/20/06 3:39:19 PM4/20/06 3:39:19 PM Bulk packaging means easier stocking abilities, less packaging waste and quicker, more convenient installation. Everything in the photo below is shipped in a recloseable box for storage of extra parts. The Fast Jack® is available in four convenient sizes. All sizes are packaged in quantities of 18 per box: 18 - 1" Round Posts (3", 4-1/2", 6" or 7-1/2" tall) 18 - Threaded bases 18 - 3/8" x 3/4" SS Hex Bolts 18 - 3/8" SS Flat washers 18 - 5/16" x 3" SS Lag bolts 18 - 5/16" SS Flat Washers Step 1: Drill Pilot hole in Rafter using integrated drill guide Step 2: Install base using includ- ed lag into pilot hole Step 3: Cut through shingles for flashing (flashing template illus- trated below) Step 4: Slide flashing under shin- gles and above Fast Jack Base Step 5: Thread post through top or bottom of flashing into FastJack® base Step 6: Using a wrench, secure post into base Step 7: Seal flashing around the post to waterproof Easy Installation: Flashing Template Available for Oatey (Pictured) and standard flashings. Makes cutting in a perfect flashing easy and painless! Kit includes Fast Jack post threader with knob © Professional Solar Products, Inc. March 2006. FASTJACK_layout3.indd 2FASTJACK_layout3.indd 2 4/20/06 3:39:23 PM4/20/06 3:39:23 PM $&&$FPH&DEOH&OLSV &RQWDFWXVDWZZZZHOOFFRP ‡0DGHZLWKFRUURVLRQUHVLVWDQWVHULHVVWDLQOHVVVWHHO ‡'XDOZLUHFRPSDUWPHQWV ‡6SHFLDOWDEIRUHDV\LQVWDOODWLRQDQGUHPRYDOZLWKÀDWKHDGVFUHZGULYHU ‡'HVLJQHGWRSUHYHQWGDPDJHWRFDEOHLQVXODWLRQ ‡6L]HGIRU86(FDEOH PP RU39FDEOH PP $&& +ROGVWR86(ZLUHV  RU39ZLUH $&&39 +ROGVWR39ZLUHV $&0(&DEOH&OLSVVLPSOLI\ZLUHPDQDJHPHQWDQGFUHDWHDFOHDQHUDHVWKHWLFWRVRODU39DUUD\V7KH FOLSVDUHPDGHRIFRUURVLRQUHVLVWDQWVWDLQOHVVVWHHODQGDUHGHVLJQHGWRSUHYHQWGDPDJHWRFDEOHLQVX ODWLRQ7KHHDV\WRLQVWDOODQGUHPRYHGHVLJQRQO\UHTXLUHVDÀDWKHDGVFUHZGULYHUDQGFDQEHUHXVHG XQOLNH]LSWLHV7KHXQLYHUVDOGHVLJQ¿WVPRVWPRGXOHVDQGFDQKROGRQHRUWZRZLUHV ‡ 0DGHRIFRUURVLRQUHVLVWDQWWLQSODWHFRSSHU ‡ 'HVLJQHQVXUHVIRUHDV\LQVWDOODWLRQ ‡ $YDLODEOH  :LWK:((% ®ZDVKHUWHFKQRORJ\  $VVHPEOHGDQGXQDVVHPEOHG  :LWKRUZLWKRXWLQVWDOODWLRQKDUGZDUH ‡ /RZSUR¿OHGHVLJQ ‡ 1RVXUIDFHSUHSHUDWLRQRQUDLORUPRGXOHUHTXLUHG ‡ 5HOLDELOLW\WKURXJKRXWWKHOLIHWLPHRIWKH39V\VWHP ‡ 0XOWLSOHHTXLSPHQWJURXQGFRQGXFWRUDOORZDQFH 2QH$:*WR$:*RUWZR$:*WZR$:* ‡ /LVWHGWR$16,8/E\,QWHUWHN(7/ ‡ &6$&HUWL¿HGWR&1R ‡ &XVWRPGHVLJQVDYDLODEOHXSRQUHTXHVW :((%®/8* 7KH:((%®/XJFRQVLVWVRID:((%®ZDVKHUOD\LQOXJDQGKDUGZDUH,WLVXVHGZLWKRQHVROLGRUVWUDQGHG FRSSHUZLUH $:*WR$:* RUWZRFRSSHUZLUHV $:*WR$:* WRSURYLGHDFRQWLQXRXVJURXQGRQURRI RUJURXQGPRXQWHGVRODUV\VWHPV8QOLNHWUDGLWLRQDOOD\LQOXJVWKH:((%®/XJGRHVQRWUHTXLUHVXUIDFH SUHSDUDWLRQRQUDLORUPRGXOHWRLQVWDOO7KH:((%®/XJLVLQVWDOOHGXVLQJVWDLQOHVVVWHHOPRXQWLQJKDUGZDUH :KHQWKHKDUGZDUHLVWLJKWHQHGWKH:((%®ZDVKHUV¶VSHFLDOL]HGWHHWKHPEHGLQWRDQRGL]HGDOXPLQXPJDOYDQL]HG VWHHORUDQ\HOHFWULFDOO\FRQGXFWLYHPHWDOWRHVWDEOLVKDJDVWLJKWHOHFWULFDOFRQQHFWLRQ7KHWLQSODWHG/XJDVVXUHV PLQLPXPFRQWDFWUHVLVWDQFHDQGSURWHFWLRQDJDLQVWFRUURVLRQ&RSSHUZLUHLVFODPSHGE\DVWDLQOHVVVWHHO VFUHZZKLFKLVKRUL]RQWDOWRWKHWDQJIRUHDV\DFFHVVZKHQPRXQWHGXQGHUD39PRGXOH7KHORZSUR¿OHRIWKH :((%®/XJDOORZVLWWREHLQVWDOOHGLQDYDULHW\RISRVLWLRQV Catalog Item # L x W x H Hole Hardware Torque :((%/8*  ´[´[´ ´ LQFKKDUGZDUH LQFOXGHGXQDVVHPEOHG IWOEVIRU WHUPLQDOVFUHZ IWOEVIRU PRXQWLQJ KDUGZDUH Z3HQHWUR[$ RQWKUHDGV :((%/8*$6  ´[´[´ LQFKKDUGZDUH LQFOXGHGDVVHPEOHG :((%/8*  ´[´[´ ´ 0RULQFKKDUGZDUH QRWLQFOXGHG :((%/8*$6  ´[´[´ LQFKKDUGZDUH LQFOXGHGDVVHPEOHG :((%/8*81  ´[´[´ LQFKKDUGZDUH LQFOXGHGXQDVVHPEOHG :((%/8*  ´[´[´ 0RULQFKKDUGZDUH QRWLQFOXGHG &XVWRPHU6HUYLFH'HSDUWPHQW $YLDWLRQ3DUN'ULYH /RQGRQGHUU\1+   ,QWHUQDWLRQDO ZZZEXUQG\FRP  ‡ 0DWHULDOWLQSODWHGFRSSHU ‡ 2XWGRRUUDWHG ‡ /RZSUR¿OHGHVLJQ ‡ 0XOWLSOHHTXLSPHQWJURXQGFRQGXFWRUDOORZDQFH 2QH$:*WR$:*RUWZR$:*WZR$:* ‡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¿OHRIWKH:,/(<*URXQGLQJ/XJDOORZVLWWREHLQVWDOOHGLQDYDULHW\RISRVLWLRQV Catalog Item # L x W x H Hole Hardware Torque :,/(</8*  ´[´[´´7HUPLQDOVFUHZLQFOXGHG :((%70QRWLQFOXGHG IWOEVIRU WHUPLQDOVFUHZ IWOEVIRU PRXQWLQJ KDUGZDUH Z3HQHWUR[$ RQWKUHDGV :,/(</8*  ´[´[´ ´ 7HUPLQDOVFUHZLQFOXGHG :((%70QRWLQFOXGHG :,/(</8*  ´[´[´ 7HUPLQDOVFUHZLQFOXGHG :((%70QRWLQFOXGHG :,/(</8*  ´[´[´ 7HUPLQDOVFUHZLQFOXGHG :((%70QRWLQFOXGHG &XVWRPHU6HUYLFH'HSDUWPHQW $YLDWLRQ3DUN'ULYH /RQGRQGHUU\1+   ,QWHUQDWLRQDO ZZZEXUQG\FRP  S 2XWGRRU UDWHG Volume 1—Residential and Light Commercial CA08100002E—January 2013 www.eaton.com V1-T1-47 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Single-Phase—Main Lug Loadcenters Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral Notes 1 Ground bar kits priced separately. See Page V1-T1-60. – For 2/4 circuit loadcenters, use GBK5 or GBK520 ground bar. – For 4/8, 6/12 and 8/16 circuit loadcenters, use GBK10 ground bar. – Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters. 2 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 3 Ground bar GBK5 is installed. 4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-60. 5 CSA and UL approved. 6 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/Al. 7 For use as service entrance applications only. 8 Neutral/ground holes (6) #14–6 and (3) #14–1/0 AWG Cu/Al. 9 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). j Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). k Ground bar GBK10 is installed. l Ground bar GBK14 is installed. Box sizes Pages V1-T1-61 through V1-T1-64. Main Ampere Rating Maximum Number 1-Inch (25.4 mm)Enclosure Type Trim Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Loadcenter Catalog NumberSpaces Circuits 70 2 4 Indoor Surface (no door) 5 #8–#2 BR24L70SP 12 2 4 Indoor Surface (no door) 5 BR24L70SGP 23 2 4 Outdoor —5R BR24L70RP 124 2 4 Indoor Flush (no door) 5 BR24L70FP 12 2 4 Indoor Flush (no door) 5 BR24L70FGP 25 125 2 4 Indoor Surface (no door) 6 #14–1/0 BR24L125SP 12 2 4 Outdoor —6R BR24L125RP 124 2 4 Outdoor —6R BR24L125RSEP 278 2 4 Outdoor —6R BR24L125RSE2P 267 2 4 Indoor Flush (no door) 6 BR24L125FP 12 4 8 Indoor Surface (no door) 7 #14–1/0 BR48L125SP 19 4 8 Indoor Surface (no door) 7 BR48L125SGP 39 4 8 Outdoor —7R BR48L125RP 149 4 8 Indoor Flush (no door) 7 BR48L125FP 19 4 8 Indoor Flush (with door) 7 BR48L125FDP 19 4 8 Indoor Flush (no door) 7 BR48L125FGP 39 6 12 Indoor Surface (no door) 7 #14–#1 BR612L125SP 1j 6 12 Indoor Surface (no door) 7 BR612L125SGP jk 6 12 Indoor Surface (with door) 7 BR612L125SDP 1j 6 12 Indoor Surface (with door) 7 BR612L125SDGP jk 6 12 Outdoor —7R BR612L125RP 14j 6 12 Indoor Flush (no door) 7 BR612L125FP 1j 6 12 Indoor Flush (no door) 7 BR612L125FGP 5jk 6 12 Indoor Flush (with door) 7 BR612L125FDP j 6 12 Indoor Flush (with door) 7 BR612L125FDGP 5jk 8 16 Indoor Surface (no door) 7 #14–#1 BR816L125SP 1j 8 16 Indoor Surface (no door) 7 BR816L125SGP jl 8 16 Indoor Surface (with door) 7 BR816L125SDP 1j 8 16 Indoor Surface (with door) 7 BR816L125SDGP jl 8 16 Outdoor —7R BR816L125RP 14j 8 16 Indoor Flush (no door) 7 BR816L125FP 1j 8 16 Indoor Flush (no door) 7 BR816L125FGP 5jl 8 16 Indoor Flush (with door) 7 BR816L125FDP 1j 8 16 Indoor Flush (with door) 7 BR816L125FDGP 5jl Surface Outdoor Flush Outdoor Surface (No Door) Flush (No Door) Outdoor V1-T1-66 Volume 1—Residential and Light Commercial CA08100002E—December 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Dimensions Approximate Dimensions in Inches (mm) Residential/Commercial/New York City Loadcenters, Unit Enclosures—Box Sizes Note: Box sizes do not include covers/fronts. Residential Loadcenters—NEMA Type 1 Indoor Residential Loadcenters—NEMA Type 3R Outdoor Commercial Loadcenters—NEMA Type 1 Indoor Commercial Loadcenters—NEMA Type 3R Outdoor New York City Loadcenters—NEMA Type 1 Indoor Types ECB and ECC Unit Enclosures—NEMA Type 1 Indoor Types ECB and ECC Unit Enclosures—NEMA Type 3R Outdoor Box Size Height Width Depth A1 15.00 (381.0) 11.25 (285.8) 3.75 (95.3) B1 16.75 (425.5) 14.31 (363.5) 3.88 (98.4) B2 18.75 (476.3) 14.31 (363.5) 3.88 (98.4) C1 21.00 (533.4) 14.31 (363.5) 3.88 (98.4) C2 23.00 (584.2) 14.31 (363.5) 3.88 (98.4) C4 27.00 (685.8) 14.31 (363.5) 3.88 (98.4) D1 29.13 (739.8) 14.31 (363.5) 3.88 (98.4) G1 34.13 (866.8) 14.31 (363.5) 3.88 (98.4) L1 39.00 (990.6) 14.31 (363.5) 3.88 (98.4) L2 45.00 (1143.0) 14.31 (363.5) 3.88 (98.4) L3 48.38 (1228.3) 14.31 (363.5) 3.88 (98.4) 2 8.63 (219.1) 5.00 (127.0) 3.50 (88.9) 3 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 4 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 5 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 6 12.00 (304.8) 6.88 (174.6) 4.50 (114.3) 7 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 9 14.50 (368.3) 6.50 (165.1) 3.50 (88.9) Box Size Height Width Depth B1R 16.75 (425.5) 14.31 (363.5) 5.19 (131.8) B2R 18.75 (476.3) 14.31 (363.5) 5.19 (131.8) C3R 25.00 (635.0) 14.31 (363.5) 5.19 (131.8) D1R 29.13 (739.8) 14.31 (363.5) 5.19 (131.8) G1R 34.13 (866.8) 14.31 (363.5) 5.19 (131.8) L1R 39.00 (990.6) 14.31 (363.5) 5.19 (131.8) L2R 45.00 (1143.0) 14.31 (363.5) 5.19 (131.8) L3R 48.75 (1238.2) 14.31 (363.5) 5.19 (131.8) 2R 8.63 (219.1) 5.00 (127.0) 3.50 (88.9) 3R 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 4R 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 5R 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 6R 11.75 (298.5) 6.50 (165.1) 4.50 (114.3) 7R 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 8R 27.00 (685.8) 10.50 (266.7) 4.75 (120.7) 9R 14.25 (362.0) 6.50 (165.1) 4.00 (101.6) C1R 21.00 (533.4) 14.31 (363.5) 5.19 (131.8) Box Size Height Width Depth 19 44.00 (1117.6) 16.16 (410.4) 6.25 (158.8) 20 44.00 (1117.6) 16.16 (410.4) 6.25 (158.8) 22 54.00 (1371.6) 16.22 (412.0) 6.31 (160.3) 24 66.50 (1689.1) 16.22 (412.0) 6.31 (160.3) Box Size Height Width Depth 42 38.00 (965.2) 16.31 (414.3) 6.38 (161.9) 43 44.00 (1117.6) 16.31 (414.3) 6.38 (161.9) 46 54.00 (1371.6) 16.31 (414.3) 6.38 (161.9) 47 66.56 (1690.7) 16.31 (414.3) 6.38 (161.9) Box Size Height Width Depth A 38.00 (965.2) 18.13 (460.4) 5.00 (127.0) B 44.00 (1117.6) 18.13 (460.4) 5.00 (127.0) C 66.50 (1689.1) 18.13 (460.4) 6.25 (158.8) Height Width Depth 23.25 (590.6) 8.88 (225.4)4.50 (114.3) Height Width Depth 23.68 (601.7)9.31 (236.5)5.44 (138.1) Th e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d / o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n . Th i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s . It i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f . Ne i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n . * P r i c e s a r e i n d i c a t i v e Feb 6, 2014 1 Product data sheet Characteristics HU462AWK SWITCH NOT FUSIBLE HD 600V 60A 4P NEMA12 Product availability: Non-Stock - Not normally stocked in distribution facility Price*: 1008.00 USD Main Commercial Status Commercialised Product or component type Single Throw Safety Switch [In] rated current 60 A Product certifications UL listed NEMA degree of protection NEMA 3R/12 galvannealed steel Device composition None Disconnector device type Non-fusible disconnect Short-circuit current 200 kA maximum Device mounting Surface Number of poles 4 Electrical connection Lugs Series name Heavy duty [Ue] rated operational voltage 600 V AC/DC AWG gauge 14...3 AWG copper or aluminium Ordering and shipping details Category 00116 - H&HU SW,4&6P,N12,30-200A Discount Schedule DE1 GTIN 00785901505105 Nbr. of units in pkg.1 Package weight(Lbs)29.60 Product availability Non-Stock - Not normally stocked in distribution facility Returnability Y Country of origin US Offer Sustainability Sustainable offer status Not Green Premium product RoHS Will be Compliant on 3Q2014 REACh Reference not containing SVHC above the threshold Contractual warranty Period 18 months