HomeMy WebLinkAboutSOLR22-1132 APPROVED REVISED PLANS.pdfH
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Jo
w
i
t
t
R
e
s
i
d
e
n
c
e
22194
47
3
0
8
A
b
d
e
l
C
i
r
c
l
e
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
6
0
9/13/2022
SF
MJR
Sheet
Michael Rango
PV-0.0
CO
V
E
R
S
H
E
E
T
DESCRIPTION OF WORK:
ROOF MOUNTED PHOTOVOLTAIC (SOLAR ELECTRIC) INSTALLATION TILT MOUNTED @ 3° FACING
AN AZIMUTH OF 179° AND 269° CONSISTING OF (26) PANASONIC EVPV400H 400 WATT
MODULES (10.4Kw).
RACK MOUNTING SYSTEM IS UNIRAC SOLARMOUNT ALUMINUM SUPPORT RAILS AND FAST JACK
SOLAR STANCHIONS.
INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES:
CEC 2019 - ARTICLE 690, 705,706 AND OTHERS NEC 2020 705.13
CPC 2019
CBC 2019
CMC 2019
CFC 2019
DRAWING SHEETS:
COVER SHEET PV-0.0
OPTIMIZER STRINGING NOTES (NOT FOR PERMITTING)PV-0.0 (2)
SITE PLAN PV-1.0
SYSTEM PERFORMANCE NOTES (NOT FOR PERMITTING)PV-1.0 (2)
ROOF PLAN PV-2.0
ROOF PLAN (continued) PV-2.1
SINGLE LINE DIAGRAM PV-3.0
MOUNTING DETAIL PV-4.0
WARNING LABELING PV-5.0
SPECIFICATION SHEETS:
EVPV400H MODULE
SE10000H-US INVERTER
UNIRAC CERTIFICATION
NTS
GENERAL NOTES:
1.ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDER THE
DIRECT SUPERVISION OF A LICENSED ELECTRICIAN.
2.ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741SA CERTIFIED
AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVED FOR IT'S
PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA
STANDARDS.
3.THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING
PROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAIC SYSTEM
WHEN THE UTILITY GRID IS NOT IN OPERATION.
4.PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCAL
AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER.
5.THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEAD
LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ON THE
ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE
PHOTOVOLTAIC SYSTEM OR INSTALLATION.
6.ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS.
7.ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE
WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS.
8.TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTURE
Palm Desert Municipal Code Requirements: (required on first page)
Basic Wind Speed: (3 second gust)
•Risk Category IV - 108 mph (Palm Desert use Category IV)
CONSTRUCTION HOURS:
OCTOBER 1 THRU APRIL 30 MAY 1 THRU SEPTEMBER 30
Monday - Friday 7:00 a.m. - 5:30 p.m. Monday - Friday 5:30 a.m. - 7:00 p.m.
Saturday 8:00 a.m. - 5:00 p.m. Saturday 8:00 a.m. - 5:00 p.m.
Sunday NOT ALLOWED Sunday NOT ALLOWED
Government Code Holidays-- NOT ALLOWED
A violation of the above work hours is a citable offense under Palm Desert Municipal Code Section 9.24.070.
Rev A 12/5/22
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
OPTIMIZER / STRINGING (INSTALLATION NOTES NOT FOR PERMITTING)
Panel S/N:
°
ABDEL CIRCLE
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Jo
w
i
t
t
R
e
s
i
d
e
n
c
e
22194
47
3
0
8
A
b
d
e
l
C
i
r
c
l
e
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
6
0
9/13/2022
SF
MJR
Sheet
Michael Rango
PV-1.0
SI
T
E
P
L
A
N
1" = 15'
SITE PLAN KEYNOTE:
EXISTING ELECTRICAL
1.1 225A MAIN ELECTRICAL PANEL
NEW ELECTRICAL
(ADJACENT TO MSP)
2.1 SYSTEM AC DISCONNECT
NEW ELECTRICAL
(INSIDE GARAGE)
2.2 SYSTEM AC DISCONNECT
2.3 SE10000H-US PV INVERTER
SITE LEGEND
EAVE SETBACK/WALL
Rev A 12/5/22
SYSTEM PERFORMANCE (INSTALLATION NOTES NOT FOR PERMITTING)
CREW NOTES:
INVERTER M/N
INVERTER S/N
STRING CONFIG
(1 column each
MPPT)
INPUT #1 2
AZIMUTH/
ORIENTATION
SLOPE/TILT
VOC @ Jbox
VOC @ Inverter
V+ to Gnd
V- to Gnd
AC L1-L2
AC L1-N
AC L2-N
AC POWER
WATTS @
TIME OF DAY
AMBIENT TEMP.
WEATHER SUNNY PARTLY CLOUDY CLOUDY
INVERTER M/N
INVERTER S/N
STRING CONFIG
(1 column each
MPPT)
INPUT #1 2
AZIMUTH/
ORIENTATION
SLOPE/TILT
VOC @ Jbox
VOC @ Inverter
V+ to Gnd
V- to Gnd
AC L1-L2
AC L1-N
AC L2-N
AC POWER
WATTS @
TIME OF DAY
AMBIENT TEMP.
WEATHER SUNNY PARTLY CLOUDY CLOUDY
INVERTER M/N
INVERTER S/N
STRING CONFIG
(1 column each
MPPT)
INPUT #1 2
AZIMUTH/
ORIENTATION
SLOPE/TILT
VOC @ Jbox
VOC @ Inverter
V+ to Gnd
V- to Gnd
AC L1-L2
AC L1-N
AC L2-N
AC POWER
WATTS @
TIME OF DAY
AMBIENT TEMP.
WEATHER SUNNY PARTLY CLOUDY CLOUDY
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Jo
w
i
t
t
R
e
s
i
d
e
n
c
e
22194
47
3
0
8
A
b
d
e
l
C
i
r
c
l
e
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
6
0
9/13/2022
SF
MJR
Sheet
Michael Rango
PV-2.0
RO
O
F
P
L
A
N
1" = 5'
1.VERIFY RAFTER SPACING IN THE FIELD BEFORE
ATTACHING MOUNTS ROOF.
2.ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF
RAFTERS AND MAKE STRUCTURAL CONNECTION TO
THE RAFTERS.
3.STRUCTURAL CONNECTION TO ENGINEERED TRUSS
SHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAG
SCREWS 3" MIN. EMBEDMENT.
4.ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS.
5.PHOTOVOLTAIC MODULES SHALL HAVE 1.7 MOUNTS
(LAG SCREWS) PER PANEL.
6.(E) ROOF STRUCTURE IS FLAT 2X10 ENGINEERED
TRUSS/JOIST 16" O.C TYP.
7.(E) ROOFING MATERIAL IS 1 LAYER OF FOAM OVER 1
LAYER OF 30LB. FELT PAPER AND 1/2" OSB PLYWOOD
DECKING.
8.MODULE DIMENSIONS 71.7" x 40"
MOUNT PLAN KEYNOTE:
RACK MOUNT COMPONENTS
1.1 UNIRAC ALUMINUM SUPPORT RAIL
1.2 FAST JACK SOLAR STANCHIONS
STRUCTURAL
2.1 ROOF SUPPORTS 2x10 ENGINEERED TRUSS/JOIST
(16" O.C.)
48" SPACING BETWEEN MOUNTS IS TYPICAL - MAX SPAN 6'
Rev A 12/5/22
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Jo
w
i
t
t
R
e
s
i
d
e
n
c
e
22194
47
3
0
8
A
b
d
e
l
C
i
r
c
l
e
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
6
0
9/13/2022
SF
MJR
Sheet
Michael Rango
PV-2.1
RO
O
F
P
L
A
N
1" = 5'
1.VERIFY RAFTER SPACING IN THE FIELD BEFORE
ATTACHING MOUNTS ROOF.
2.ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF
RAFTERS AND MAKE STRUCTURAL CONNECTION TO
THE RAFTERS.
3.STRUCTURAL CONNECTION TO ENGINEERED TRUSS
SHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAG
SCREWS 3" MIN. EMBEDMENT.
4.ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS.
5.PHOTOVOLTAIC MODULES SHALL HAVE 1.5 MOUNTS
(LAG SCREWS) PER PANEL.
6.(E) ROOF STRUCTURE IS FLAT 2X10 ENGINEERED
TRUSS/JOIST 16" O.C TYP.
7.(E) ROOFING MATERIAL IS 1 LAYER OF FOAM OVER 1
LAYER OF 30LB. FELT PAPER AND 1/2" OSB PLYWOOD
DECKING.
8.MODULE DIMENSIONS 71.7" x 40"
MOUNT PLAN KEYNOTE:
RACK MOUNT COMPONENTS
1.1 UNIRAC ALUMINUM SUPPORT RAIL
1.2 FAST JACK SOLAR STANCHIONS
STRUCTURAL
2.1 ROOF SUPPORTS 2x10 ENGINEERED TRUSS/JOIST
(16" O.C.)
48" SPACING BETWEEN MOUNTS IS TYPICAL - MAX SPAN 6'
Rev A 12/5/22
C
AC OUT
PV DC IN
2 STRINGS OF 13
J-BOX
BA
SOLAREDGE POWER OPTIMIZER P400
RATED DC INPUT POWER - 400 WATTS
MAXIMUM INPUT VOLTAGE - 80 VDC
MPPT RANGE - 8 TO 80 VDC
MAXIMUM INPUT CURRENT - 12.5 ADC
MAXIMUM OUTPUT CURRENT - 15 ADC
STRING LIMITATIONS - 8 TO 25 OPTIMIZERS,
5250 WATTS STC PER STRING MAXIMUM
C
200A
BREAKER
(E)
MAIN SERVICE PANEL
225A BUSS,
120/240V, 1PH, 3W
MSP
60A
SE10000H-US = 42A x 1.25 = 52.5A
225A x 1.2 = 270A
270A - 200 = 70A
52.5A <= 70A
(N)
PV DISCONNECT
DG322URB
ADJACENT TO INVERTER
60A/240V
60A
60A/240V
(N)
SYSTEM DISCONNECT
DG322NRB
ADJACENT TO MSP
EXISTING AC GROUNDING ELECTRODE CONDUCTOR
PROVIDE NEW ELECTRODE IF NOT EXISTING
PER CEC 250.53 (A)(2)
10,400 WATT DC (9,807 WATT AC)
SOLAR ELECTRIC ARRAY
26 PANASONIC 400 WATT MODULES
MODEL NO. EVPV400H
26 x 381.0 PTC x 99% EFF = 9.807 kW AC
INDIVIDUAL MODULE RATING:
PTC = 381.0 WATTS
Voc = 48.8 VDC
Isc = 10.25 AMPS
INTEGRATED GFCI AND
240 VAC, 42 AMPS MAX
OUTPUT: 10000 WATTS MAX
INPUT: 400 TO 480 VDC
GRID-TIE INVERTER
SOLAREDGE SE10000H-US
OUTPUT EFFICIENCY: 99%
DC DISCONNECTS
NOTES:EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690, 705 , 706 AND OTHERS.
1. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS
A PHOTOVOLTAIC DISCONNECT.
2. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING-ELECTRIC SHOCK HAZARD - DO NOT TOUCH
TERMINALS-TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION"
3. PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2.
INVERTER OUTPUT VOLTAGE
4. LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS
PER NEC 690-64(b)7.
5. INDIVIDUAL INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE.
6.ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE.
7.ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBLE TO ANYONE OTHER THAN QUALIFIED PERSONS.
8.ALL PV SYSTEM EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY.
9.ALL EXTERIOR WIRING MATERIAL SHALL BE SUITABLE FOR A SUN EXPOSURE AND WET LOCATIONS.
10.REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR
OUTPUT CIRCUIT CONDUCTOR.
11.CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED.
12.ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2019 CALIFORNIA ELECTRIC CODE & NEC 2020 705.13.
13.BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT.
14.ANY LOADS RELOCATED TO A BU LOADS PANEL BEYOND SIX FEET SHALL REQUIRE AFCI PROTECTION.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Jo
w
i
t
t
R
e
s
i
d
e
n
c
e
22194
47
3
0
8
A
b
d
e
l
C
i
r
c
l
e
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
6
0
9/13/2022
SF
MJR
Sheet
Michael Rango
PV-3.0
SI
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
NTS
Rev A 12/5/22
Scale: 1" = 1'
5-7 DEGREE TILT DETAIL1
MOUNT DETAIL KEYNOTE:
RACK MOUNT COMPONENTS
1.1 PHOTOVOLTAIC MODULE
1.2 MODULE CLAMP
1.3 UNIRAC "SOLARMOUNT" SUPPORT RAIL
1.4 SS RAIL T-BOLT AND NUT
1.5 UNIRAC L-FOOT
1.6 ADJUSTABLE ALL TREAD
1.7 FAST JACK SOLAR STANCHION (4.5" - 7" typical)
1.8 3.5" SS LAG SCREWS (3" minimum embedment )
STRUCTURAL
2.1 FOAM ROOF
2.2 30LB FELT PAPER
2.3 1/2" OSB ROOF DECKING
2.4 2 x 10 ENGINEERED TRUSS (RAFTER) 16" O.C. TYP.H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Jo
w
i
t
t
R
e
s
i
d
e
n
c
e
22194
47
3
0
8
A
b
d
e
l
C
i
r
c
l
e
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
6
0
9/13/2022
SF
MJR
Sheet
Michael Rango
PV-4.0
AT
T
A
C
H
M
E
N
T
D
E
T
A
I
L
1" = 5'
Rev A 12/5/22
WARNING
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE AND LOAD SIDE
MAYBE ENERGIZED IN THE OPEN POSITION
DC DISCONNECTS AND J-BOXES
CAUTION:
SOLAR ELECTRIC SYSTEM CONNECTED
PLACE ON MSP
CONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTING
ALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BE
INSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALL
ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED.
CEC ARTICLES 690.56(B) AND 705.10.
FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALL
LETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHER
RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT.
NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B)(2)
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
CEC 690.56(C)(1)(A)
Label for PV Systems that shut down the array and the conductors leaving the array.
The title “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” shall utilize capitalized characters with a
minimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall be
capitalized with a minimum height of 4.8 mm (3∕16 in.) in black on white background.
WARNING
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE
THIS OVER CURRENT DEVICE
ADJACENT TO BACK FED BREAKER
705.12(B)(1)(3)(b)
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
PLACE NEXT TO INVERTER AC DISCONNECTS
690.56(C)(3)
WARNING:
PHOTOVOLTAIC POWER SOURCE
CONDUITS AND RACEWAYS EVERY 10'
690.31(G)(3)
SERVICE PANEL (YOU ARE HERE)SYSTEM AC DISCONNECT
HOT PURPLE ENERGY
760.322.4433N
1 2
43
LEGEND:
THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR
PANELS ON ROOF
CAUTION
47308 ABDEL CIRCLE, PALM DESERT, CA 92260
PV INVERTERSYSTEM AC DISCONNECT
MAXIMUM VOLTAGE 480 V
MAXIMUM CIRCUIT CURRENT 27 A
MAX RATED OUTPUT CURRENT OF
THE CHARGE CONTROLLER
OR DC-TO-DC CONVERTER
(IF INSTALLED)15A
SE10000H-US
PLACE ON DC DISCONNECT
PV SYSTEM AC DISCONNECT
WARNING - DUAL POWER SOURCE
SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM
MAX AC CURRENT : 42 A
AC VOLTAGE : 240 V
PLACE ON SYSTEM DISCONNECTS
PLACE ON PV SYSTEM DISCONNECT
PV SYSTEM DISCONNECT
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Jo
w
i
t
t
R
e
s
i
d
e
n
c
e
22194
47
3
0
8
A
b
d
e
l
C
i
r
c
l
e
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
6
0
9/13/2022
SF
MJR
Sheet
Michael Rango
PV-5.0
WA
R
N
I
N
G
L
A
B
E
L
S
NTS
Rev A 12/5/22