HomeMy WebLinkAboutCarbon MonoxidePage 1 of 1
CITY OF PALM DESERT PERMIT #_____________
Building & Safety Department
73-510 Fred Waring, Palm Desert, CA (760) 776-6420
SMOKE & CARBON MONOXIDE ALARM RETROFIT
2019 California Residential Code sections R314.8 and R315.2
Where a permit is required for alterations, repairs or additions exceeding $1,000, including exterior work, i.e. roofing,
HVAC change-outs, electrical panel upgrades, windows, etc. existing dwelling or sleeping units that have attached
garages or fuel burning appliances including fireplaces shall have a carbon monoxide alarm.
Smoke and Carbon monoxide alarms shall be installed in the following manner:
•In each sleeping room (only require Smoke Alarms unless bedrooms contain a gas appliance then a carbon
monoxide alarm is required as well)
•Outside each separate sleeping area in the immediate vicinity of the bedrooms. (require Smoke and Carbon
Monoxide Alarms)
•In each story level of the dwelling, including basements and habitable attic rooms (require Smoke and Carbon
Monoxide Alarms)
•Smoke alarms and smoke detectors shall not be located where ambient conditions, including humidity and
temperature are outside the limits specified by the manufacturer’s published instructions
•Installation near bathrooms. Smoke alarms shall be installed not less than a 3 ft. horizontal distance from the door
or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm
required by other sections of the code
•Smoke alarms and smoke detectors shall not be installed within 36 in. horizontal path from the supply registers of a
forced air heating or cooling system and shall be installed outside of the direct airflow from those registers
•Smoke alarms and smoke detectors shall not be installed within a 36 in. horizontal path from the tip of the blade of
a ceiling-suspended (paddle) fan
•Smoke Detectors shall be within 10 years of manufacture marked date and/or replaced if such date does not exist
•Conventional Ionization smoke alarms must be installed with a ten year battery
Interconnection:
Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit
the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms. Exception:
Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling
fini shes, or there is no access by means of attic, basement or crawl space.
The Building Inspector will verify the installation of the smoke and carbon monoxide alarms during the inspection
process or the owner can complete and sign under the penalty of perjury the following:
I understand the above requirements and certify that we now have smoke alarms and carbon monoxide alarms
installed that comply. I agree to comply with the CRC in regards to smoke alarms and carbon monoxide alarms.
I, ________________________________ and I, ______________________________ who own and/or live in the
(Property Owner’s name) (Tenant’s name/same)
Dwelling located at: ____________________________________________________________________________
_____________________________________________ _______________________________________________
Signature of Owner Date Signature of Tenant Date
*This is a voluntary smoke and carbon monoxide alarm verification procedure. If you prefer a building inspector to
perform the verification, you must arrange to have an adult present at the time of inspection.
*Note, this verification is only used when normal access to the interior of the dwelling is not achieved during the course
of project construction. It is normally used for projects such as re-roofing, re-siding, patio covers or swimming pools.