Loading...
HomeMy WebLinkAbout2023-01-10 ARC Regular Meeting Agenda Packet City of Palm Desert Page 1 ARCHITECTURAL REVIEW COMMISSION CITY OF PALM DESERT, CALIFORNIA AGENDA (HYBRID MEETING) City Hall, Development Services Conference Room 73-510 Fred Waring Drive Palm Desert, CA 92260 Pursuant to Assembly Bill 361, this meeting may be conducted by teleconference. There will be in-person public access to the meeting location. OPTIONS FOR PARTICIPATING IN THIS MEETING: • Attend the meeting in the Development Services Conference Room at Palm Desert City Hall, 73510 Fred Waring Drive, Palm Desert, CA 92260. • To participate via Zoom, use the following link: https://palmdesert.zoom.us/j/83648797515, Zoom Webinar ID: 836 4879 7515. • To participate by telephone call (213) 338-8477 or (669) 219-2599, Zoom Webinar ID: 836 4879 7515. To provide a public comment please press *9 to raise your hand. • Written public comment may also be submitted to planning@cityofpalmdesert.org. Emails received by 9:30 a.m. prior to the meeting will be distributed to the Commission. Any correspondence received during or after the meeting will be distributed to the Commission as soon as practicable and retained for the official record. Emails will not be read aloud except as an ADA accommodation. 1. CALL TO ORDER 2. ROLL CALL 3. NON-AGENDA PUBLIC COMMENT: This time has been set aside for the public to address the Architectural Review Commission on issues that are not on the agenda for up to three minutes. Because the Brown Act does not allow the Commission to act on items not listed on the agenda, members may briefly respond or refer the matter to staff for a report and recommendation at a future meeting. 4. CONSENT CALENDAR: All matters listed on the Consent Calendar are considered routine and may be approved by one motion. The public may comment on any items on the Consent Agenda within the three-minute time limit. Individual items may be removed by Commissioners for a separate discussion. Tuesday January 10, 2023 12:30 p.m. Regular Meeting Architectural Review Commission Agenda January 10, 2023 City of Palm Desert Page 2 A. APPROVAL OF MINUTES RECOMMENDATION: Approve the Architectural Review Commission Regular Meeting minutes of December 13, 2022. B. CASE NO: SARC22-0007 NATURE OF PROJECT/APPROVAL SOUGHT: Consideration to approve a Design Review for a multi-tenant monument sign for an existing office building located at 73161 Fred Waring Drive. APPLICANT AND ADDRESS: Signarama, Palm Desert, CA 92260 LOCATION: 73161 Fred Waring Drive, Suite#200 ZONE: Office Professional (O.P.) RECOMMENDATION: 1. Approve Case No. SARC22-0007. 2. All new landscaping shall have a minimum specimen size of 5-gallons. CONSENT ITEMS HELD OVER: Items removed from the Consent Calendar for separate discussion will be considered at this time. 5. ACTION CALENDAR A. FINAL DRAWINGS 1. CASE NO: MISC22-0043 NATURE OF PROJECT/APPROVAL SOUGHT: Consideration to approve a materials exception for an existing fence in the front yard setback of a single-family residence located at 77100 Indiana Avenue. APPLICANT AND ADDRESS: Theresa Illare, Palm Desert, CA 92211 LOCATION: 77100 Indiana Avenue ZONE: Single-Family Residential (R-1) RECOMMENDATION: 1. The ARC continues Case No. MISC22-0043 to a date uncertain. 2. CASE NO: MISC21-0023 NATURE OF PROJECT/APPROVAL SOUGHT: Consideration to approve a Design Review for a four-story, 96-room, 83,106-square-foot Staybridge Suites hotel located at 74755 Technology Drive (APN 694-190-096) APPLICANT AND ADDRESS: PVG Architects, Palm Desert, CA 92260 LOCATION: 74755 Technology Drive Architectural Review Commission Agenda January 10, 2023 City of Palm Desert Page 3 ZONE: Planning Area (PA) 5 of Millennium Palm Desert Specific Plan (MPD SP) / Planned Commercial (PC-2) RECOMMENDATION: 1. The ARC determines that the requirements of the findings have been met based on the analysis and approves the Design Review for Case No. MISC21-0023 as presented. 2. Any modifications required by the ARC be added to the motion as conditions of approval. B. MISCELLANEOUS None 6. INFORMATIONAL REPORTS & COMMENTS A. ARCHITECTURAL REVIEW COMMISSIONERS B. CITY STAFF C. ATTENDANCE REPORT 7. ADJOURNMENT: The next Regular Meeting will be held on January 24, 2023, at 12:30 p.m. Architectural Review Commission Agenda January 10, 2023 City of Palm Desert Page 4 AFFIDAVIT OF POSTING I hereby certify under penalty of perjury under the laws of the State of California that the foregoing agenda for the Architectural Review Commission was posted on the City Hall bulletin board and City website not less than 72 hours prior to the meeting. Melinda Gonzalez Recording Secretary PUBLIC NOTICES Agenda Related Materials: Pursuant to Government Code §54957.5(b)(2) the designated office for inspection of records in connection with this meeting is the Development Services Department, City Hall, 73-510 Fred Waring Drive, Palm Desert. Staff reports for all agenda items and documents provided to a majority of the legislative bodies are available for public inspection at City Hall and on the City’s website at www.cityofpalmdesert.org. Americans with Disabilities Act: It is the intention of the City of Palm Desert to comply with the Americans with Disabilities Act (ADA) in all respects. If, as an attendee or a participant at this meeting, or in meetings on a regular basis, you will need special assistance beyond what is normally provided, the city will attempt to accommodate you in every reasonable manner. Please contact the Office of the City Clerk, (760) 346-0611, at least 48 hours prior to the meeting to inform us of your needs and to determine if accommodation is feasible. City of Palm Desert Page 1 ALL ACTIONS ARE DRAFT, PENDING APPROVAL OF THE MINUTES ARCHITECTURAL REVIEW COMMISSION CITY OF PALM DESERT, CALIFORNIA MINUTES (HYBRID MEETING) Pursuant to Assembly Bill 361, this meeting may be conducted by teleconference. There will be in-person public access to the meeting location. 1. CALL TO ORDER A Regular Meeting of the Architectural Review Commission (ARC) was called to order by Vice Chair McIntosh on Tuesday, December 13, 2022, at 12:31 p.m. in the Development Services Conference Room, City Hall, located at 73510 Fred Waring Drive, Palm Desert, California. 2. ROLL CALL Present: Commissioners Dean Wallace Colvard, Nicholas Latkovic, Michael McAuliffe, Vice Chair McIntosh, and Francisco Sanchez. Absent: Chair John Vuksic. City Staff Present: Richard Cannone, Director of Development Services; Nick Melloni, Senior Planner, and Melinda Gonzalez, Recording Secretary, were present at Roll Call. 3. NON-AGENDA PUBLIC COMMENT Vice Chair McIntosh opened and closed the non-agenda public comment period. No public comments were provided. 4. CONSENT CALENDAR Associated staff reports, memos, attachments, and discussion on the following items can be viewed by visiting the Architectural Review Commission Information Center website at, https://www.cityofpalmdesert.org/our-city/committees-and-commissions/commission- information. MOTION BY COMMISSIONER MCAULIFFE, SECOND BY COMMISSIONER LATKOVIC, CARRIED 5-0; (CHAIR VUKSIC ABSENT), to approve the consent calendar. A. APPROVAL OF MINUTES MOTION BY COMMISSIONER MCAULIFFE, SECOND BY COMMISSIONER LATKOVIC, CARRIED 5-0; (CHAIR VUKSIC ABSENT), to approve the Architectural Review Commission Regular Meeting minutes of November 22, 2022. Tuesday December 13, 2022 12:30 p.m. Regular Meeting Architectural Review Commission Agenda December 13, 2022 City of Palm Desert Page 2 ALL ACTIONS ARE DRAFT, PENDING APPROVAL OF THE MINUTES CONSENT ITEMS HELD OVER: Items removed from the Consent Calendar for separate discussion will be considered at this time. None 5. ACTION CALENDAR Associated staff reports, memos, attachments, and discussion on the following items can be viewed by visiting the Architectural Review Commission Information Center website at, https://www.cityofpalmdesert.org/our-city/committees-and-commissions/commission- information. A. FINAL DRAWINGS 1. CASE NOS: PP/CUP 17-059 – Amendment #1 / EA 22-0007 / PMW 22-0008 (Continued from November 22, 2022) NATURE OF PROJECT/APPROVAL SOUGHT: Consideration to approve a Design Review for Amendment No. 1 to Precise Plan (PP) / Conditional Use Permit (CUP) 17- 059 to expand an existing CarMax, auto sales use, including a 2,351 square-foot building addition, construction of a new 923-square-foot carwash tunnel, canopy area, and new sales staging area located at 73-450 and 73-500 Dinah Shore Drive. APPLICANT AND ADDRESS: Michael Baker International, Palm Desert, CA LOCATION: 73-450 and 73500 Dinah Shore Drive ZONE: Service Industrial - SI Senior Planner, Nick Melloni, narrated a PowerPoint presentation on the item and responded to Commission inquiries. Bill Pope with MBI, Applicant, and Allan Price, Architect, with Pieper O’Brien Herr Architects, provided additional information on the project and answered questions from the Commission. Vice Chair McIntosh opened and closed the public comment period. No public comments were provided. Discussion on the item ensued with Commissioners providing comments for the project. Following discussion, MOTION BY COMMISSIONER MCAULIFFE, SECOND BY COMMISSIONER COLVARD, CARRIED 5-0; (CHAIR VUKSIC ABSENT) to: 1. Approve Case Nos. PP/CUP 17-059 – Amendment #1 / EA 22-0007 / PMW 22- 0008 with conditions. 2. The applicant shall construct the wall enclosing the vehicle staging area with a tan split face block and pilasters facing Dinah Shore Drive, and the northern property line, spaced no greater than 30 feet apart. 3. All roof drainage on the proposed additions shall utilize internal roof drains except on the north elevations of the main sales and service building. 4. The areas indicated by dark earthtone stucco located on the tower elements of the south and east elevations of the sales addition shall be recessed a minimum of 0’- 8” from the fascia of the tower element. Final construction drawings shall provide sufficient details for this change. Architectural Review Commission Agenda December 13, 2022 City of Palm Desert Page 3 ALL ACTIONS ARE DRAFT, PENDING APPROVAL OF THE MINUTES B. MISCELLANEOUS None 6. INFORMATIONAL REPORTS & COMMENTS A. ARCHITECTURAL REVIEW COMMISSIONERS None B. CITY STAFF Senior Planner, Nick Melloni, provided the following updates: • PP/EA22-0005 West Coast Storage and PP/CUP22-0006 394-units on the SWC of Portola Ave. and Frank Sinatra Drive went before the Planning Commission on December 6, 2022, both projects were approved. • A workshop was held last week for the proposed North Sphere Regional Park. Director of Development Services, Richard Cannone, added a follow up workshop is scheduled for January 15, 2023. Information on the follow up workshop will be sent to commissioners when available. • Avenida Palm Desert is currently installing their roof screening. • The next regularly scheduled Architectural Review Commission meeting on December 27, 2022, will be canceled due to lack of a quorum. Cancellation notices will be posted as required and emailed to Commissioners. • An update to the City’s Accessory Dwelling Unit (ADU) ordinance will go before the City Council for adoption at their next meeting, December 15, 2022. C. ATTENDANCE REPORT The attendance report was provided with the agenda materials. The Commission took no action on this matter. 7. ADJOURNMENT The Architectural Review Commission adjourned at 1:21 p.m. Respectfully submitted, Melinda Gonzalez, Senior Administrative Assistant Recording Secretary ATTEST: Rosie Lua, Deputy Director of Development Services Secretary APPROVED BY ARC: __/__/2022 CITY OF PALM DESERT DEVELOPMENT SERVICES DEPARTMENT ARCHITECTURAL REVIEW COMMISSION MEMORANDUM To: Honorable Chair and Members of the Commission From: Anna Dan, Assistant Planner Date: January 10, 2023 Subject: SARC22-0007 – Consideration to approve a Design Review for a multi-tenant monument sign for an existing office building located at 73161 Fred Waring Drive. BACKGROUND The Applicant, Signarama, is requesting approval of a new multi-tenant monument sign for an existing office building located at 73161 Fred Waring Drive. The monument sign will be installed in the landscaped parking lot buffer fronting Fred Waring Drive and constructed out of an aluminum frame with a masonry base. The frame will be painted to complement the existing office building and feature internally illuminated push-through letters for the name panels. PROJECT SUMMARY A. Property Description The project site is an existing office building complex located on Fred Waring Drive, approximately 430 feet west of San Anselmo Avenue. The site is comprised of one parcel totaling 0.33-acres, or 14,613 square feet, containing one (1) two-story office building with a total floor area of approximately 4,400 square-feet and 24 parking spaces. The site is zoned Office Professional (O.P.). The building complex was approved in 1997 per Case No. PP 97- 15 by adopted Planning Commission Resolution No. 1836; with construction completed in 1999. The original entitlement proposed a tenant sign wall on the north-facing elevation where there is a landscaped lawn; however, no sign wall was constructed. Currently, there are no exterior walls signs for the existing tenants. There are three (3) tenant spaces in the building operating as administrative offices which include a utility construction company, a human resources consulting firm, and a security company. SARC 22-0007 – 73161 Fred Waring Dr. Monument Sign Page 2 of 4 January 10, 2023 B. Adjacent Land Use and Zoning Designation Table 1 – Adjacent Land Use and Designations Existing Uses General Plan Zoning Project Site Professional Office Neighborhood Center Office Professional (O.P.) North Parking Lot Downtown Downtown Edge District (D.E.) South Single Family Residential Small Town Neighborhood Residential Single Family (R-2) East Medical Center Neighborhood Center Office Professional (O.P.) West Dental Office Neighborhood Center Office Professional (O.P.) C. Project Description The project is a request to construct a new monument sign in an existing landscaped parking lot buffer fronting Fred Waring Drive. Presently, there are no signs located on the exterior of the building or site perimeter. The monument sign will serve as the main identification sign for the tenants of the office building. The sign features a modern design with a rectangular body and minimal massing. The sign is 5’-2” tall, 5’-6” long, 1’-6” wide, and setback 12 feet from the face of curb. At this location, the sign does not create a line-of-sight issue since all traffic is eastbound and the sign does not obstruct visibility when entering or leaving the site. The sign is constructed from 0.080” gauge aluminum, three (3) internally illuminated aluminum routed tenant panels with ½-inch push- through acrylic letters. The letters are finished with vinyl faces, painted black and brown, and mounted on brushed aluminum panels. The aluminum frame is painted beige (SW 6078 Realist Beige) and dark brown (PPU5-19 Dark Truffle) with a fine grit textured finish to complement the architecture of the existing building. The monument sign will be placed in a landscaped area with additional proposed planting including: • One (1) Yucca Plant • Two (2) Yellow Lantana Zoning Ordinance Summary Pursuant to Section 25.68.050 of the Palm Desert Municipal Code (PDMC), all freestanding signs (monument signs) require Architectural Review Commission (ARC) review and approval. The standards for permanent identification signs are listed under Section 25.56.070 (D) and Section 25.56.080 (B)(2) of the Sign Ordinance. Compliance with the PDMC is summarized below. Table 2 – Monument Sign Conformance Determination Standard Ordinance Project Conformance Determination Sign Area 50 square feet 20 square feet Yes Sign Height 6 feet 5 feet, 2 inches Yes Number per Frontage 1 1 Yes Illumination Internal or external Internal Yes SARC 22-0007 – 73161 Fred Waring Dr. Monument Sign Page 3 of 4 January 10, 2023 Additionally, all monument signs are required to be placed in a permanently landscaped area not less than 24 square feet. The proposed sign will be in a 200 square-foot parking lot buffer with existing landscape to be replaced as shown in the landscape plan. The messaging on the sign is limited to the tenant names and five-digit address number, no phone numbers are included. Per PDMC 25.56.030 (E), when approving or rejecting a sign permit application, the ARC shall consider the design review criteria provided below and shall make the following findings: 1. That the sign is necessary for the applicant’s enjoyment of substantial trade and property rights. The sign is necessary to provide adequate identification to customers and employees of the businesses in the building as it is located on a high-volume vehicular arterial (Fred Waring Drive). 2. That the sign is consistent with the intent and purpose of this chapter and title. The sign is consistent with the intent and purpose of the Sign Ordinance as the sign is designed in harmony with the existing building and complies with all applicable development standards. 3. That the sign does not constitute a detriment to public health, safety, and welfare. The design of the sign does not constitute a detriment to public health, safety, and welfare as the design of the sign does not incorporate elements that are distracting or intrusive to motorists or pedestrians. The placement of the sign is not anticipated to create sight obstruction to motorists or pedestrians as it is setback away from line of site areas, adjacent streets, and drive aisles. The proposed sign is setback 12 feet from the face of the street curb. 4. That the size, shape, color, height, and placement of the sign is compatible with and will have a harmonious relationship with the building it identifies, the surrounding neighborhoods, and other signs in the area. The size of the sign complies with the development standards established in the City’s Sign Ordinance and is in scale with the existing building. The location of the sign in the landscaped parking lot buffer is typical of the other monument signs along the south side of Fred Waring Drive. The aluminum frame is painted with a desert palette that complements the plaster and split face block of the existing building, and the acrylic letter faces contrast against the lighter background. 5. That both the location of the proposed sign and the design of its visual elements (lettering, words, figures, colors, decorative motifs, spacing, and proportions) are legible under normal viewing conditions prevailing where the sign is to be located. The sign is oriented in a manner to be visible to pedestrians and motorists traveling along Fred Waring Drive. The black and brown lettering against the brushed aluminum panel provides enough contrast to be legible under typical viewing conditions. The letters are also internally illuminated to allow for visibility in non-daylight hours. SARC 22-0007 – 73161 Fred Waring Dr. Monument Sign Page 4 of 4 January 10, 2023 6. That the location, height, and design of the proposed sign does not obscure from view or unduly detract from existing or adjacent signs and does not in any way compromise the health or safety of any person(s). The location, height, and design of the proposed sign does not obscure view or unduly detract from existing signs in the vicinity and does not adversely affect the public health safety or welfare. The height of the sign conforms to the Ordinance and is setback 12 feet from the face of the curb to ensure consistency among business frontages along Fred Waring. 7. That the location and design of the proposed sign and its size, shape, illumination, and color are compatible with the visual characteristics of the surrounding area so as not to detract from or cause depreciation of the value of adjacent developed properties. The height and size of the sign comply with the requirements found in Table 25.56-2 of the Sign Ordinance. The Applicant is proposing a dark brown and light beige contrast that complement the existing building. 8. That the location and design of a proposed sign in close proximity to a residential district does not adversely affect the value or character of the adjacent residential uses. The sign is compatible with the design of the building and meets the requirements established in Table 25.56-2 for commercial signage, so it will not adversely impact the character of adjacent commercial and residential uses. Additionally, the sign is located on the south side of Fred Waring Drive, a predominantly commercial and office arterial. The sign does not directly face existing residential uses. 9. That any neon tubing used in conjunction with any sign is incorporated as an integral part of the sign design with careful attention to color, intensity of light, and the use of colors that are not overly bright. No neon tubing is proposed as part of the monument sign. The sign will be internally illuminated by light emitting diodes (LED) in a manner that complies with the Sign Ordinance requirements for cabinet signs. 10. That the quantity of information displayed in the sign does not cause visual clutter. The signage text is limited to the name of the respective tenants and the property address number. Staff Recommendation. Staff recommends the ARC determines that the requirements of the findings have been met based on the analysis and approves the Sign Design Review with the following condition: 1. All new landscaping shall have a minimum specimen size of 5-gallons. Attachment: 1. Project Exhibits CITY OF PALM DESERT DEVELOPMENT SERVICES DEPARTMENT ARCHITECTURAL REVIEW COMMISSION MEMORANDUM To: Honorable Chair and Members of the Commission From: Anna Dan, Assistant Planner Date: January 10, 2023 Subject: MISC22-0043 – Consideration to approve a materials exception for an existing fence in the front yard setback of a single-family residence located at 77100 Indiana Avenue. BACKGROUND The subject case is a consideration to approve a materials exception for an existing fence in the front yard setback of a single-family residence located at 77100 Indiana Avenue. In accordance with Palm Desert Municipal Code (PDMC) 25.40.080, the exception was scheduled to be reviewed by the Architectural Review Commission (ARC) and adjacent property owners were mailed a notice of application. The notice of application stated that the Applicant, Theresa Illare, is requesting a material exception for an existing 4-foot, 8-inch tall fence, setback 16 feet from the face of curb, and constructed out of wood and steel. The PDMC limits the material of all fences visible from the public right of way to decorative block, stucco, or wrought iron. The exception was scheduled to be reviewed by the ARC on January 10, 2023. Following an onsite inspection by staff, the existing fence measured 5 feet, 2 inches tall with a setback of 16 feet, 3 inches from the face of curb which is inconsistent with the information provided in the initial application. At a setback of 16 feet, 3 inches, the code limits the height of the fence to a maximum of 4 feet, 11 inches. Therefore, staff has determined the applicant will need to amend the application to include a request for a height exception. Staff recommends Case No. MISC22-0043 be continued to a date uncertain and that adjacent property owners receive an updated notice of application. CITY OF PALM DESERT DEVELOPMENT SERVICES DEPARTMENT ARCHITECTURAL REVIEW COMMISSION MEMORANDUM To: Honorable Chair and Members of the Commission From: Nikki Gomez, Assistant Planner Date: January 10, 2023 Case No: MISC21-0023 Subject: Consideration to approve a Design Review for a four-story, 96-room, 83,106 square- foot Staybridge Suites hotel located at 74755 Technology Drive (APN 694-190-096) BACKGROUND On March 26, 2015, the City Council adopted Ordinance No. 1281 approving the Millennium Palm Desert Specific Plan (MPDSP). The MPDSP consists of a 152± acre area located near the City’s northern city limits, south of Interstate-10 and the Union Pacific Railroad, between Portola Avenue and Cook Street. It is bounded by Portola Avenue on the west, Gerald Ford Drive on the south, and Technology Drive on the east. The project is a new Staybridge Suites hotel located on Planning Area 5 of the MPDSP. Planning Area 5 of the MPDSP allows for the development of between 175 to 250 hotel rooms up to four (4) stories. On July 17, 2018, the Planning Commission adopted Resolution No. 2724 approving Precise Plan (PP) 18-0002 and Tentative Parcel Map (TPM) 37488 within PA 5. The PP approved the site design for two (2) four (4) story hotels developed in two phases. The Tentative Parcel Map approved the subdivision of the 3.92-acre lot into two parcels: • Parcel 1 – 1.91 acres – Phase 2, Future 90-room hotel (Proposed Staybridge) • Parcel 2 – 1.96 acres – Phase 1, 96-room room hotel (Holiday Inn Express) Phase One (Parcel 2) consisting of a four-story, 96-room Holiday Inn Express and Suites, 105 parking spaces, and landscaping, was completed in 2021. Phase Two (Parcel 1) included a four- story, 90-room future hotel, 105 parking spaces, and landscaping. An approval by the Architectural Review Commission (ARC) would be required to proceed with construction of Phase 2. On March 12, 2019, the applicant, Prest-Vuksic Architects, Inc. received approvals by the ARC, Case No. MISC 19-0005 approving the architecture and landscaping for a 90-room, four story Staybridge Suites hotel. On July 29, 2021, the applicant, ACE Design LLC, filed a new application (MISC21-0023) for a revised design for the Staybridge Suites hotel. MISC 21-0023 – Staybridge Suites Page 2 of 7 January 10, 2023 On October 12, 2021, the Staybridge Suites Hotel project was brought before the ARC for a preliminary review and discussion of architectural design. The ARC requested for the item to be continued and rescheduled to a future ARC meeting as the project applicant was unavailable to provide a presentation to the Commissioners. On October 26, 2021, the Staybridge Suites Hotel project was presented to the ARC as a preliminary review for architectural comments. The ARC provided design comments and concerns for the project, but no action was taken on the item as it was brought forth solely for ARC comments. PROJECT SUMMARY On December 20, 2022, the project applicant, PVG Architects on behalf of Desert Hospitality Group, submitted a revised design for the Staybridge Suites hotel (MISC 21-0023). The proposed hotel is four stories and contains 96-rooms totaling 83,106 square feet with guest amenities including a fitness room, outdoor pool, and patio area. There are two (2) vehicular access driveways off Technology Drive and associated parking areas. The project landscaping is comprised of a mix of low and moderate water usage desert native plant species. A. Property Description: The proposed hotel project will be situated at the northernmost part of Planning Area 5 (APN:694- 190-096), Phase 2 of the hotel development under PP18-0002 on a 1.91-acre parcel north of the newly built Holiday Inn Express and Suites within the MPDSP. B. Zoning, General Plan and Adjacent Uses: Table 1 – Adjacent Land Use and Designations Existing Uses General Plan Zoning Project Site Vacant Neighborhood Center (NC) Planning Area (PA) 5 of MPD SP/ PC (2) Planned Commercial North Vacant Neighborhood Center (NC) PA 4 of MPDSP / S.I. Service Industrial South Holiday Inn Suites Neighborhood Center (NC) PA 5 of MPDSP / PC (2) Planned Commercial East Hotel (Fairfield Inn and Suites) Town Center Neighborhood (TC) PC-3, FCOZ – Planned Commercial, Freeway Commercial Overlay District West Vacant – Approved Millennium Apartments 330 Units Town Center Neighborhood (TC) PA 7 of MPDSP / PR Planned Residential - 22 MISC 21-0023 – Staybridge Suites Page 3 of 7 January 10, 2023 Building Design and Architecture The hotel architecture is a desert contemporary design. It is characterized by angular and layered pop-outs and complimentary contrasting earthtone exterior colors. The elevation depicts recessed windows with metal awnings adding shade and shadow elements throughout the building facade. The building exterior materials and finish supports the contemporary modern design including acrylic smooth sand stucco finish in five earthtones colors. Accent tile with wood design finish will be installed on the first floor, southwest corner, visible at the entrance of the proposed hotel building. The metal roofing is narrow batten in a dark bronzed color. The roof line of the main building is characterized by varying parapet heights generally at 47 feet high and punctuated by a butterfly roof tower as the tallest element at 62 feet in height. Site Plan and Parking The proposed hotel site will share vehicular and pedestrian access and drainage between Parcel 1 (Holiday Inn Express and Suites Hotel) and Parcel 2 (Staybridge Suites Hotel). The hotel is an “L” shape footprint centrally located on the project site with two access points from Technology Drive. Drive lanes are 30-feet wide, adequate for fire access and circulation with shared vehicular and pedestrian access between Parcel 1 and 2 from the west portion of both parcels. The parking area surrounds the building footprint, with retention areas to the west and southwest portion of the project site fronting Technology Drive. There are 108 parking spaces for the proposed hotel and 106 existing parking spaces (Holiday Inn Express and Suites Hotel) totaling in 214 parking spaces. The project will construct a retention basin which will serve parcels 1 and 2 of PM 37488. Access and Circulation The proposed hotel will have two vehicular access points, totaling four vehicle access points from Technology Drive as approved by PP18-0002 between the existing hotel and the proposed hotel. Screening The butterfly tower element serves as screening for the rooftop mechanical equipment. The butterfly tower element height of 15 feet high is sufficient for a man door access while completely screening the proposed mechanical equipment at 4 feet, 5 inches in height. The fire riser and electrical rooms are integrated into the first floor of the hotel. The pool equipment located behind the hotel will be screened using a block wall with an access gate. Landscape Landscape for the site consists of a mix of desert appropriate live plant materials which includes the following: Trees: • California Fan Palm (Washingtonia Fillifera), Swan Hill Olive Tree (Olea Europaea), Mulga Tree (Acacia Aneura). All tree specimens will be a minimum 24-inch box size at the time of planting and low and moderate water use. MISC 21-0023 – Staybridge Suites Page 4 of 7 January 10, 2023 Shrubs/Accents/Groundcover: • Low Water Usage: Parry’s Agave, Ocahui Agave, Barbados Aloe, Grey Desert Spoon, Emu Bush, Pink Parade Yucca, Cimeron, Little Illie Olive • Moderate Water Usage: Beauty Natal Plum, Green Carpet Natal Plum, Spotted Emo Bush, Purple Lantana, New Gold Lantana, Philodendron, Cape Honey Suckle All proposed shrubs and plants will be a minimum 5-gallon size at the time of planting. Hardscape: • Primary ground cover: 3/8-inch Tan Decomposed Granite (Mojave Gold) • Accent: Cobble, Copper Canyon – 1-inch to 3-inch rock • Boulders: (84 total) which consist of 48 boulders which are 1 foot x 2 feet in size, 28 boulders which are 2 feet x 3 feet, and 8 boulders which are 3 feet x 4 feet. Under the MPDSP, landscaping should provide shade where needed including parking areas. The landscape plan shows shade trees such as Swan Hill Olive and Mulga trees in the parking areas and around the retention areas. In addition, the landscape treatments should maximize the use of native desert and compatible drought-tolerant plant materials. The proposed landscape consists of native desert and drought-tolerant plan materials. Furthermore, final landscape plans will be submitted to the City’s Planning Department and the Coachella Valley Water District for review and approval to ensure plant species are compliant with water conservation ordinance requirements. ANA LYSIS Development Standards The project site is zoned Planned Commercial (PC-2) within the MPDSP which allows for hotel uses with the approval of a Precise Plan (PP) by the Palm Desert Planning Commission in accordance with Palm Desert Municipal Code Section (PDMC) 25.72.030. The Planning Commission previously approved PP18-0002 which complied with development standards provided for Planning Area 5 of the Millennium Palm Desert Specific Plan. The table below summarizes the project’s conformance analysis for the proposed hotel project, Staybridge Suites Hotel (Phase 2): Table 2 – Development Standard Consistency STANDARD PC 2 (PLANNING AREA 5) PROJECT CONFORMS Lot Size, Min. 1 acre 1.91 acre Yes Front Yard Setback 0’-0” 49’-6” Yes Side Yard Setback 0’-0” 56’-2”, 11’-6” Yes Street Side Yard Setback 0’-0” NA NA Rear Yard Setback 0’-0” 0’-0” Yes Floor Area Ratio 0.50 0.24 Yes MISC 21-0023 – Staybridge Suites Page 5 of 7 January 10, 2023 Maximum Height, Hotel and Mixed Use*** 50’-0” 47’ building height and 62’-0” tower height highlighting the entrance Yes Maximum No. of Stories 4 Stories 4 Stories Yes Maximum Building Size 100,000 square feet 83,106 square feet Yes Minimum Landscaping (% of lot area) 15% 22% Yes Parking Requirement 1.1 per guest unit – 106 parking spaces 108 parking spaces Yes Table 2 shows that the proposed project conforms with the MPDSP Development Standards. The project lot size is 1.91 acres which is above the minimum 1-acre lot size requirement. The front setback of 49 feet, 6 inches, side setbacks of 56 feet, 2 inches and 11 feet, 6 inches, and 0’ rear yard setback is in conformance as the allowable setback is 0’ from front, side, and rear yard. The building floor ratio is .24 which is within the .50 ratio standard. The proposed hotel is at four-stories which conforms with the height standard. The proposed hotel is 83,106 square feet which is within the 100,000 square foot maximum building size. The project site landscape area is 22% conforming with the 15% minimum landscape percentage lot area. The proposed 108 parking spaces exceeds the required 106 parking spaces. Under the MPDSP, “Table 4 – Planning Areas 3,5 and 6 Development Standards”, identifies the maximum height for a hotel is 50 feet, with a notation that “Maximum height not including architectural projects and towers which may exceed this standard.” The proposed hotel elevations show the building height of 47 feet with a butterfly roof tower element of an additional 15 feet extending the overall height to 62 feet. Since towers may exceed the 50 feet height standard, the proposed hotel conforms with the MPDSP. Parking Under PDMC Section 25.46.040 Parking Requirements, there is a parking ratio of 1.1 parking space per room. The proposed hotel contains 96 rooms which requires 106 parking spaces. The proposed site plan includes a total of 108 parking spaces, exceeding the minimum parking requirements by two 2spaces. ZONING ORDINANCE SUMMARY ARC approval of a design review is required for development of a vacant parcel for a proposed hotel project per PDMC Section 25.68.020(A). Findings for ARC decisions are listed under PDMC Section 25.68.040 – Findings of the ARC. Findings in support of the project are listed below: To approve a design review application, the ARC shall find the following: A. That the proposed development conforms to any legally adopted development standards. The proposed hotel complies with the original development standards adopted per the MPDSP and is consistent with the prior entitlement approval under Planning Commission MISC 21-0023 – Staybridge Suites Page 6 of 7 January 10, 2023 Resolution No. 2724 regarding the building height, setbacks, parking, and number of hotel rooms. The proposed hotel elevations show the building height of 47 feet with a butterfly roof tower element of an additional 15 feet extending the overall height to 62 feet. Under the MPDSP, architectural projects and towers may exceed the 50-foot hotel height standard. The proposed hotel will have 96 rooms, the recently completed hotel has 96, totaling 192 rooms, and falls within the allowable range of the 175 to 250 rooms allowed under the MPDSP and CEQA Mitigated Negative Declaration. The proposed development conforms with legally adopted development standards set forth by Planning Area 5 of the Millennium Palm Desert Specific Plan. B. That the design and location of the proposed development and its relationship to neighboring existing or proposed developments and traffic is such that it will not impair the desirability of investment or occupation in the neighborhood; and that it will not unreasonably interfere with the use and enjoyment of neighboring existing or proposed developments and that it will not create traffic hazards or congestion. The proposed 4-story hotel is compatible with existing developments surrounding the project site. The existing site has been previously approved as a two-phased hotel development with Phase 1 (Holiday Inn Express & Suites) to the south of the proposed hotel. To the east area of the project site is a 4-story hotel, Fairfield Inn & Suites. The northeast area includes a federal building (Department of Motor Vehicles) and a local restaurant/brewery. The southern area consists of a 3-story hotel (Hampton Inn & Suites) and a multi-tenant commercial building with fast casual restaurants. The surrounding area consists of hotels and complimentary commercial uses. The proposed hotel project will utilize egress and ingress from Technology Drive. Under the MPDSP, a traffic study was prepared and identified Technology Drive as a “Collector Street” with an ultimate width of a 72-foot Right of way (ROW) which is an acceptable level of service. The site plan proposes 108 parking spaces exceeding the minimum parking requirement of 106 parking spaces. C. That the design and location of the proposed development is in keeping with the character of the surrounding neighborhood and is not detrimental to the harmonious, orderly, and attractive development contemplated by this title and the General Plan of the City The proposed four-story hotel is an allowable land use within Planning Area 5 of the MPDSP. The land use and site plan were previously evaluated under Planning Commission Resolution No. 2724 which approved the second hotel on the project site, and the project conforms to all applicable development standards of the MPDSP. The architecture, landscaping, building height and scale complement the recently completed Holiday Inn Express and Suites hotel located south of the proposed project site. Existing developments within the site vicinity are a variety of mixed uses including office, retail, restaurant, four-story hotels, and nearby planned three-story multi-family apartment developments. The architecture, color palette and landscaping are designed to be harmonious, orderly, and attractive development envisioned by the General Plan and Zoning and MPDSP. D. That the design and location of the proposed development would provide a desirable environment for its occupants, as well as for its neighbors, and that it is aesthetically of good composition, materials, textures, and colors. The proposed design utilizes high-quality finishes and features a contemporary style characterized by angular and layered pop-outs and complimentary contrasting earthtone MISC 21-0023 – Staybridge Suites Page 7 of 7 January 10, 2023 exterior colors. The buildings provide for a quality visual aesthetic along Technology Drive. The project proposes extensive onsite landscaping including a mix of desert appropriate live plant materials which is consistent with the existing newly built hotel to the south, . E. That the proposed use conforms to all the requirements of the zone in which it is located and all other applicable requirements. The proposed development conforms with legally adopted development standards for Planning Area 5 of the MPDSP. A summary of the conformance with these development standards, including setbacks, lot coverage, building height, open space, and parking is provided on the conformance analysis under Table 2, provided on pages four and five of this staff report. As summarized, the project conforms with all applicable development standards. The proposed rooftop equipment and other site utilities are screened in accordance with PDMC 25.40.090. F. That the overall development of the land shall be designed to ensure the protection of the public health, safety, and general welfare. The approved preliminary grading plan for PP18-0002 was utilized for the proposed hotel project to ensure the design of the project incorporates the proper improvements including adequately sized retention basins for onsite drainage. In addition, the overall building design ensures the protection of the public health, safety, and general welfare. The proposed project includes hard surface pedestrian pathways and connections from the public right of way to ensure walkability throughout. STAFF RECOMMENDATION Staff recommends the ARC determines that the requirements of the findings have been met based on the analysis and approves the Design Review for Case No. MISC21-0023 as presented. Any modifications required by the ARC be added to the motion as conditions of approval. Attachment: 1. Project Exhibits 2. Resolution No. 2724 approving Precise Plan (PP) 18-0002 3. Parcel Map (TPM) 37488 4. Notice of Action for MISC21-0023 dated November 11, 2021 PREST | VUKSIC | GREENWOOD A R C H I T E C T S I N T E R I O R S VICINITY MAP Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A001 SHEET INDEX SHEET INDEX SHEET NO.SHEET NAME A000 COVER SHEET A001 SHEET INDEX A002 CONTEXTUAL SITE PLAN GROSS LOT AREA NAME S.F. TOTAL LOT AREA 37,666.39 S.F. PROJECT INFORMATION EDDIE SANIN 77682 COUNTRY CLUB DRIVE STE H PALM DESERT, CA. 92211 760.409.5958 EDDIE@DESERTGATEREALESTATE.COM OWNER PREST VUKSIC GREENWOOD ARCHITECTS JOHN VUKSIC 44530 SAN PABLO AVENUE, SUITE 200 PALM DESERT, CA 92260 760.779.5393 JOHNV@PVGARCH.COM APPLICANT ASSESSOR'S PARCEL APN 625-091-008 . Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 T E C H N O L O G Y D R I V E T E C H N O L O G Y D R I V ENOPARK ING STAYBRIDGE SUITES4 STORY96 ROOMS PATIO4 STORY POOL595 SQ.FTPOOLEQUIPMENTHOLIDAY INN EXPRESS HOTEL4 STORY/ 96 ROOMSPARCEL-2BUILDING BBUILDING APOOLEQUIPMENTSTAIR 1UPUPTECHNOLOGY DRIVEPROJECT SITEPUBLICLand Planning Civil Engineering Architectural Design Structural EngineeringACE Design LLCACE Design LLCFOLSOM, CA 956301024 IRON POINT ROAD, SUITE 1046Phone: (702) 396-5113, Fax: (702)446-8155 1%GERALDFORD DRIVECITY OFPALM DESERTFRANK SINAIRA DRIVETECHNOLOGYDRIVEVARNER ROADGERALDFOOD DRIVEPORTOLA AVENUE COOK STREET PROJECT2"(MIN.)4" CONCRETE SIDEWALK T E C H N O L O G Y D R I V E T E C H N O L O G Y D R I V ENOPARK ING STAYBRIDGE SUITES4 STORY96 ROOMS PATIO4 STORY POOL595 SQ.FTPOOLEQUIPMENTCROSSACCESSHOLIDAY INN EXPRESS HOTEL4 STORY/ 96 ROOMSPARCEL-2BUILDING BBUILDING APOOLEQUIPMENTSTAIR 1UPUPLand Planning Civil Engineering Architectural Design Structural EngineeringACE Design LLCACE Design LLCFOLSOM, CA 956301024 IRON POINT ROAD, SUITE 1046Phone: (702) 396-5113, Fax: (702)446-8155 GERALDFORD DRIVECITY OFPALM DESERTFRANK SINAIRA DRIVETECHNOLOGYDRIVEVARNER ROADGERALDFOOD DRIVEPORTOLA AVENUE COOK STREET PROJECTVERTICAL SEPARATION OF MINIMUM 0.5' BETWEEN WATER AND SEWER/STORM DRAINLINES TO BE PROVIDED. PLACE WATER LINE ABOVE SEWER/STORM DRAIN LINE.MAINTAIN A MINIMUM COVER OF 3.5' BETWEEN TOP OF THE WATER LINE ANDFINISHED SURFACE ELEVATION.VERTICAL SEPARATION OF MINIMUM 1.0' BETWEEN STORM DRAIN AND SEWER LINES TOBE PROVIDED.INSTALL 6" EXTRA STRENGTH VCP SEWER PIPE PER ASTM C70012INSTALL 6" SEWER CLEAN OUT PER CVWD STANDARD DETAIL NO. S-6 ON C4 SHEET.346INSTALL 10"x6"x8" TEE.7INSTALL 10" DCDA FOR FIRE WATER LINE PER CVWD STD. DWG. NO. W-50 ON C4 SHEET8PROPOSED 8" PVC C-900 FIRE WATER SERVICE LINE.9PROPOSED 6" PVC C-900 FIRE WATER SERVICE LINE.10INSTALL 8"x6"x6" TEE.INSTALL 6" GATE VALVE PER CVWD STD. DWG. NO. W-33A ON C4 SHEET11PROPOSED FIRE HYDRANT PER CVWD STD. DWG. NO. W-33A ON C4 SHEET1213INSTALL POST INDICATOR VALVE14INSTALL 6" FIRE DEPARTMENT CONNECTION15PROPOSED 3" PVC SCH 80 DOMESTIC WATER LINE.INSTALL 3" RPPA FOR DOMESTIC SERVICEPROPOSED 3" WATER METER FOR DOMESTIC SERVICE16171819PROPOSED 1.0" WATER METER FOR IRRIGATION SERVICE20INSTALL 1.0" RPPA FOR IRRIGATION LINEINSTALL 1.0" TYPE 'K' COPPER IRRIGATION WATER LINE21CONSTRUCT THRUST BLOCKS PER CVWD STD. DWG. NO. W-19/S-19 & W-20/S-20 ON C4 SHEET5INSTALL 6" CHECK VALVEINSTALL 6" SEWER CLEAN OUT PER CVWD STANDARD DETAIL NO. S-45 ON C4 SHEET.INSTALL UL LISTED 6" SINGLE PIECE CORROSION-RESISTANT STAINLESS STEEL PER DETAIL #1 ON THIS SHEET22INSTALL UL LISTED 3" SINGLE PIECE CORROSION-RESISTANT STAINLESS STEEL WATER LINE FOR DOMESTIC SERVICE23EX. UNDERGROUND CABLE LINE COMING UNDER RETENTION BASIN TO BE RELOCATED24INSTALL 90° BEND (PIPE SIZE PER PLAN)25INSTALL 11.25° BEND (PIPE SIZE PER PLAN)26INSTALL 135° BEND (PIPE SIZE PER PLAN) T E C H N O L O G Y D R I V E T E C H N O L O G Y D R I V ENOPARK ING STAYBRIDGE SUITE S 4 STORY96 ROOMS P A T I O 4 STORY POOL595 SQ.FTPOOLEQUIPMENT HOLIDAY INN EXPRESS HOTEL4 STORY/ 96 ROOMSPARCEL-2BUILDING BBUILDING APOOLEQUIPMENTSTAIR 1UPUPCONTECH UNDERGROUND 60" CORRUGATED METAL PIPESTORMWATER RETENTION SYSTEM TYPICAL SECTION1Land Planning Civil Engineering Architectural Design Structural EngineeringACE Design LLCACE Design LLCFOLSOM, CA 956301024 IRON POINT ROAD, SUITE 1046Phone: (702) 396-5113, Fax: (702)446-8155 GERALDFORD DRIVECITY OFPALM DESERTFRANK SINAIRA DRIVETECHNOLOGYDRIVEVARNER ROADGERALDFOOD DRIVEPORTOLA AVENUE COOK STREET PROJECT Land Planning Civil Engineering Architectural Design Structural EngineeringACE Design LLCACE Design LLCFOLSOM, CA 956301024 IRON POINT ROAD, SUITE 1046Phone: (702) 396-5113, Fax: (702)446-8155 6" AREA = 7600 S. F.FIRERISER R M. KITCH E N 009 ENGIN E E RI N G STAIR 1 FITNE S S CENT E R 039ELEC.028MECH A NI C AL 032TLT006 TLT 007 BREA K ROOM020 OPS019NTWK024TLT021 BAG. 017 GM OF FI C E 023SALE S 018ADMIN016THELAUND R Y ROOM031 WELC O M E TABLE 014LOBBY002 LIVING ROOM003 TLT 035 TLT034 VEST. CART015 FOYER004CORR. E 030PBX 005 BOH CORRI D O R 025CORR. C 038 CORR. D033BOH V E S T.027GREAT ROOM 011 CORR. A.1 THE P A NT R Y 013 LOBBY CIRCUL A TI O N 012 037 LAUN D R Y 026ICE STORAGE022BUFFE T 010 FOYE R 036 KITCH E N ENTR Y 009A ELEV EQUIP ROOM 027A 4 SF ATM 004A ELEV. L O B B Y X50 ELEV. 2 ELEV. 1 ELEV. L O B B Y X50 ELEV. 2 ELEV. 1LINEN CHUT E 3' - 0 "1-S1FE FE FE STUDI O KI N G A 1041 BED R O O M KING106 STUDI O Q U E E N QUEE N A D A CUST O MI S E 102 STUDI O KI N G A 101STAIR 2 STUDI O KI N G A 108 1 BED R O O M QUEE N Q U E E N 103STUDI O KI N G A 1 BED R O O M QUEE N Q U E E N 107 STUDI O KI N G A 109 STUDI O KI N G A 111STUDI O KI N G A 112 STUDI O KI N G A 110 1-S2 10500884'-0"3:12:13:117'12'15'17'8' WIDE BIKE PATH114640114637GBBDE.1EBEXISTING FAIRFIELD INN A100.2 1 T E C H N O L O G Y D R I V ECANO P Y A B O V E CANO P Y A B O V E CANO P Y A B O V E CANOPY ABOVECC C CANO P Y A B O V E CANO P Y ABOV E NO PARKI N GL1.1 (2)16 16 11 28 5 4 7 5 3 2 3 34 10 8 17 6 15 8 8 4 STAYBRIDGE SUITES 4 STORY/ 96 ROOMS APPROVED HOLIDAY INN EXPRESS 4 STORY/ 96 ROOMS 2 Sheet:TECHNOLOGY DRIVE - PALM DESERT, CALIFORNIA Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S• I N T E R I O R S 1" = 40'-0" A100.1 OVERALL SITE PLAN 0' 20' 40' 80'160' PARKING DATA PARKING SPACES REQUIRED BY CITY OF PALM DESERT: (1.1 PARKING SPACE PER ROOM) STAYBRIDGE SUITES 96 ROOMS X 1.1 =106 SPACES HOLIDAY INN EXPRESS 96 ROOMS X 1.1 =106 SPACES TOTAL PARKING REQUIRED =212 SPACES PARKING SPACES PROVIDED ON EACH PROPERTY: NOTE STAYBRIDGE SUITES, PALM DESERT, WAS DESIGNED WITH A LINEAR FOOTPRINT DUE TO THE SITE CONSTRAINTS, RATHER THAN THE PROTOTYPICAL U-SHAPED FOOTPRINT. ROOMS IMPACTED BY THIS DESIGN DEVIATION HAVE BEEN ARRANGED WITHIN THE NEW FOOTPRINT AT EACH END. STAYBRIDGE SUITES 108 SPACES HOLIDAY INN EXPRESS 104 SPACES TOTAL PARKING PROVIDED =212 SPACES (2 PARKING SPACES ARE SHARED WITH STAYBRIDGE SUITES 16 11 7 16 7 10 7 6 13 34 18 PROPERTY LINEPROPERTY LINEPROPERTY LINE6 T E C H N O L O G Y D R I V EFUTURE ACCESS POINT RETENTION AND LANDSCAPING PROPERTY LINE TRASH ENCLOSURE PROPERTY LINEENTRY STAYBRIDGE SUITES 4 STORY/ 96 ROOMS APPROVED HOTEL RETENTIONAND LANDSCAPING15'-0"20'-3" CONCRETE PAD (AT LEAST 15'-0" X 16'-0" X 6"D) IN FRONT OF ENCLOSURE GATE TO ACCOMMODATE WEIGHT OF TRASH TRUCK. RESERVED PARKING SIGNAGE FOR CHECK-IN (3 LOCATIONS) OUTDOOR LIVING SPACE POOL EQUIPMENT TO BE ENCLOSED 21'-6"30'-0" OUTDOOR POOL PAVILION 30' - 0" CLR18'-0"16'-6"15'-0"30'-0" 16'-6"30'-0"16'-6"15'-0"BCANOPY ABOVE CANOPY ABOVE CANOPY ABOVE CANOPY ABOVECCC CANOPY ABOVE CANOPY ABOVE NO PARKING L1.1 (2) 16 11 7 3 34 10 8 17 6 15 8 2 8 4 AREA = 7600 S.F. FIRERISER RM. KITCHEN 009 ENGINEERING STAIR 1 FITNESS CENTER 039 ELEC. 028 MECHANICAL 032 TLT 006 TLT 007 BREAK ROOM 020 OPS 019 NTWK 024 TLT 021 BAG. 017 GM OFFICE 023 SALES 018 ADMIN 016 THE LAUNDRY ROOM 031 WELCOME TABLE 014 LOBBY 002 LIVING ROOM 003 TLT 035 TLT 034 VEST. CART 015FOYER004 CORR. E 030 PBX 005 BOH CORRIDOR 025 CORR. C 038 CORR. D033BOH VEST. 027 GREAT ROOM 011 CORR. A.1 THE PANTRY 013 LOBBY CIRCULATION 012 037 LAUNDRY 026 ICE STORAGE022BUFFET 010 FOYER 036 KITCHEN ENTRY 009A ELEV EQUIP ROOM 027A 4 SF ATM 004A ELEV. LOBBY X50 ELEV. 2ELEV. 1 ELEV. LOBBY X50 ELEV. 2ELEV. 1 LINEN CHUTE 3'-0"1-S1 FE FE FE STUDIO KING A 104 1 BEDROOM KING 106 STUDIO QUEEN QUEEN ADA CUSTOMISE 102 STUDIO KING A 101 STAIR 2 STUDIO KING A 108 1 BEDROOM QUEEN QUEEN 103 STUDIO KING A 1 BEDROOM QUEEN QUEEN 107 STUDIO KING A 109 STUDIO KING A 111 STUDIO KING A 112 STUDIO KING A 110 1-S2 105 008 17'-0" 18'-0" Sheet:TECHNOLOGY DRIVE - PALM DESERT, CALIFORNIA Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S• I N T E R I O R S 1" = 20'-0" A100.2 SITE PLAN STAYBRIDGE SUITES 0' 10' 20' 40'80' Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Sheet: Scale: INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T 44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260 I I WWW.PVGARCHITECTS.COM PREST VUKSIC GREENWOOD A R C H I T E C T S • I N T E R I O R S A501 Date Created 12/04/22STAYBRIDGE SUITESP.O. Box 5891 La Quinta, CA. 92248jose@garzaconcepts.com www.garzaconcepts.comLlic # 1050039 TECHNOLOGY DRIVE AND GERALD FORD PALM DESERT, CALIFORNIA SHEET INDEX STAYBRIDGE SUITES NEW LANDSCAPE CONSTRUCTION PLANS FOR: SITE MAP Important Notice - Underground Service Alert Section 4216/4217 of the Government Code requires a Dig Alert Identification Number be issued before a "Permit to Excavate" will be valid. For your Dig Alert Identification Number call Underground Service Alert. TOLL FREE at 1-800-227-2600 two working days before you dig. Construction contractor agrees that in accordance with generally accepted construction practices, construction contractor will be required to assume sole and complete responsibility for job site conditions during the course of construction of the project, including safety of all persons and property, that this requirement shall be made to apply continuously and not be limited to normal working hours, and construction contractor further agrees to defend, indemnify and hold design professional harmless from any and all liability, real or alleged, in connection with the performance of work on this project, excepting liability arising from the sole negligence of design professional. SHEET NO. SHEET DESCRIPTION C1.0 TITLE SHEET L1.0 LANDSCAPE PLAN L1.1 LANDSCAPE LEGEND L1.2 LANDSCAPE PICTURES L1.3 LANDSCAPE DETAILS APN: 694-190-085 & a portion of 694-190-086 TECHNOLOGY DRIVE & GERALD FORDPALM DESERT, CALIFORNIAAPN: 694-190-085 & portion of 6994-190-086TITLE SHEETC1.0 N PROJECTREVISED 1 2 3 4 5 GARZA CONCEPTSJOSE GARZA LANDSCAPE CONTRACTOR AND DRAFTING SERVICESPLAN CHECK BY: APPROVED BY: CITY ENGINEER NOTE: NO PERMANENT STRUCTURES OR TREES WITHIN CVWD AND/OR USBR EASEMENTS. CVWD WILL NOT BE RESPONSIBLE FOR DAMAGE OR REPLACEMENT OF ANY SURFACE IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO, DECORATIVE CONCRETE, LANDSCAPING, CURB, GUTTER, SIDEWALKS, PLANTERS, GATES AND RELATED IMPROVEMENTS INSTALLED WITHING CVWD AND/OR USBR EASEMENTS NO TREES SHALL BE INSTALLED WITHIN 15ft OF A CVWD AND/OR USBR PIPELINE. SURFACE IMPROVEMENTS MAY BE INSTALLED WITHIN CVWD AND/OR USBR EASEMENT ONLY UPON THE PRIOR CONSENT OF CVWD, WHICH CONSENT MAY BE GRANTED OR DENIED AT CVWD'S SOLE DISCRETION. IN THE EVENT OF SUCH CONSENT, THEN A NON-INTERFERENCE REVIEW LETTER (NIRL) MAY APPLY PER SECTION 3.4 OR CVWD'S DEVELOPMENT DESIGN MANUAL. PROJECTO LOCATION PROJECT INFORMATION SCOPE OF WORK: Installation of Irrigation, Plant Material and Landscape Lighting LEGAL ADDRESS: STAYBRDIGE SUITES TECHNOLOGY DRIVE & GENERAL FORD PALM DESERT, CALIFORNIA PARCEL NUMBER A.P.N. 694-190-085 & portion of 694-190-086 DESIGNER: HOURS OF CONSTRUCTION October 1st through April 30th: Monday - Friday: 7:00AM to 5:30PM Saturday: 8:00AM - 5:00PM Sunday: None Government Code Holidays: None No person doing or causing work prohibited by Subsection A of this section, after being informed orally or in writing that the work has caused noise or sounds which disturb any other person's peace and quiet, shall fail, refuse or neglect to take whatever steps or use whatever means are necessary to assure that the work does not again disturb the other person's peace and quiet. May 1st through September 30th: Monday - Friday: 6:00AM to 7:00PM Saturday: 8:00AM - 5:00PM Sunday: None Government Code Holidays: None PROJECT DESCRIPTION: 96 ROOM 4 STORY HOTEL GARZA CONCEPTS JOSE GARZA LANDSCAPE CONTRACTOR AND DRAFTING SERVICES Date Created 12/04/22STAYBRIDGE SUITESP.O. Box 5891 La Quinta, CA. 92248jose@garzaconcepts.com www.garzaconcepts.comLlic # 1050039 GARZA CONCEPTSJOSE GARZA LANDSCAPE CONTRACTOR AND DRAFTING SERVICESTECHNOLOGY DRIVE & GERALD FORDPALM DESERT, CALIFORNIAAPN: 694-190-085 & portion of 6994-190-086PROJECTLANDSCAPE PLANREVISED 1 2 3 4 5 L1.0PRELIMINARY12' bth 12'bth 12' bth 12' bth 12' bth 12' bth 18' bth 15' bth 12' bth 18' bth 12' bth 15' bth 18' bth 12' bth 15' bth 12' bth 12' bth 12' bth 12' bth 12' bth Date Created 12/04/22STAYBRIDGE SUITESP.O. Box 5891 La Quinta, CA. 92248jose@garzaconcepts.com www.garzaconcepts.comLlic # 1050039 GARZA CONCEPTSJOSE GARZA LANDSCAPE CONTRACTOR AND DRAFTING SERVICESTECHNOLOGY DRIVE & GERALD FORDPALM DESERT, CALIFORNIAAPN: 694-190-085 & portion of 6994-190-086PROJECTLANDSCAPE PLANREVISED 1 2 3 4 5 L1.1 PLANT LEGEND BOTANICAL NAME QTY California Fan Palm Washingtonia Fillifera 18' bth Olea Europaea 'Swan Hill' Swan Hill Olive 4 Carissa Macrocarpa 'Boxwood' Beauty Natal Plum Hesperaloe X 'Pink Parade' Pink Parade Yucca Dasylirion Wheeleri Grey Desert Spoon Carissa Macrocarpa "Green Carpet'' Green Carpet Natal Plum Leucophyllum Zygephyllum' Cimarron' Cimeron Aloe Barbadensis Barbados Aloe 81 Agave Ocahui Ocahui Agave 18 18 18 Acacia Aneura Mulga Tree 15 13 21 Eremophila Hygrophana Bluebell Emu Bush 19 Eremophila Maculata 'Valentine' Spotted Emu Bush 19 30 Olea Europaea 'Little Ollie' Little Illie Olive 20 Lantana Montevidensis 'Purple' Purple Lantana x PRELIMINARYSYMBOL COMMON NAME SIZE 3 24" box 5 gal 5 gal 5 gal 5 gal 24" box 5 gal 5 gal 5 gal 5 gal 5 gal 5 gal 5 gal MOD MOD LOW LOW MOD MOD LOW MOD LOW MOD LOW LOW MOD .50 .50 0.2 0.2 0.2 0.5 .50 0.2 0.5 0.2 0.5 0.2 0.2 0.5 WATER NEEDS PLANT FACTOR SKINNED NOTES 15' bth3 12' bth12 LOW BRANCHING STANDARD Agave Parryi Parry's Agave 24 5 gal LOW 0.2 Lantana Montevidensis 'New Gold' New Gold Lantana 18 5 gal MOD 0.5 LOW Philodendron X 'Xanadu' Philodendron 44 5 gal MOD 0.5 VINES / ESPALIER Tecoma Capensis Cape Honeysuckle 8 5 gal MOD 0.5 SHRUBS PALMS & TREES GROUND COVER COBBLE COPPER CANYON 3,050 sq.ft.1" - 3" DECOMPOSED GRANITE MOJAVE GOLD 10,082 sq.ft.3/8" MINUS BOULDERS DESERT SELECT 1' X 2' 2' X 3' 3' X 4' 46 28 8 Date Created 12/04/22STAYBRIDGE SUITESP.O. Box 5891 La Quinta, CA. 92248jose@garzaconcepts.com www.garzaconcepts.comLlic # 1050039 GARZA CONCEPTSJOSE GARZA LANDSCAPE CONTRACTOR AND DRAFTING SERVICESTECHNOLOGY DRIVE & GERALD FORDPALM DESERT, CALIFORNIAAPN: 694-190-085 & portion of 6994-190-086PROJECTPLANT IMAGESREVISED 1 2 3 4 5 L1.2 18' bth Olea Europaea 'Swan Hill' Swan Hill Olive 4 Carissa Macrocarpa 'Boxwood' Beauty Natal Plum Hesperaloe X 'Pink Parade' Pink Parade Yucca Dasylirion Wheeleri Grey Desert Spoon Carissa Macrocarpa "Green Carpet'' Green Carpet Natal Plum Leucophyllum Zygephyllum' Cimarron' Cimeron Aloe Barbadensis Barbados Aloe 58 Agave Ocahui Ocahui Agave 9 8 12 Acacia Aneura Mulga Tree 15 1321 Eremophila Hygrophana Bluebell Emu Bush 15 Eremophila Maculata 'Valentine' Spotted Emu Bush 19 24 Olea Europaea 'Little Ollie' Little Illie Olive 15 Lantana Montevidensis 'Purple' Purple Lantana x 3 24" box 5 gal 5 gal 5 gal 5 gal 24" box 5 gal5 gal 5 gal 5 gal 5 gal 5 gal 5 gal 15' bth3 12' bth9 Agave Parryi Parry's Agave 24 5 gal Lantana Montevidensis 'New Gold' New Gold Lantana 18 5 gal Philodendron X 'Xanadu' Philodendron 44 5 gal Tecoma Capensis Cape Honeysuckle 8 5 gal COBBLE COPPER CANYON 2,406 sq.ft.1" - 3" DECOMPOSED GRANITE MOJAVE GOLD 8,190 sq.ft.3/8" MINUS BOULDERS DESERT SELECT 1' X 2' 2' X 3' 3' X 4' 46 28 8 California Fan Palm Washingtonia Fillifera Date Created 12/04/22STAYBRIDGE SUITESP.O. Box 5891 La Quinta, CA. 92248jose@garzaconcepts.com www.garzaconcepts.comLlic # 1050039 GARZA CONCEPTSJOSE GARZA LANDSCAPE CONTRACTOR AND DRAFTING SERVICESTECHNOLOGY DRIVE & GERALD FORDPALM DESERT, CALIFORNIAAPN: 694-190-085 & portion of 6994-190-086PROJECTLANDSCAPE DETAILSREVISED 1 2 3 4 5 L1.3 PALM TREE PLANTING NOTES 1. PALMS SHALL BE PLANTED USING ESTABLISHED PLANTING PROCEDURES NOTED ON PLANTING DETAILS. 2. PALM TREE ROOT BALLS SHALL BE TRIMMED OR CUT TO ENSURE RECOVERY FROM TRANSPLANTING SHOCK. 3. PALM TREES MUST BE IN A HEALTHY CONDITION AT TIME OF DELIVERY. PALM TREES DETERMINED UNHEALTHY OR DAMAGED AT TIME OF DELIVERY OR INTALLATION SHALL BE REJECTED BY CONTRACTOR AND REPLACED BY SUBCONTRACTOR AT HIS EXPENSE. 4. ALL PALMS SHALL BE CLEANED OF ECESSIVE DEAD AND RAGGED FRONDS OR FROND STUBBLE. CUT FRONDS SHOULD BE CUT TO A MAXIMUM LENGHT OF 6". 5. CALLED OUT HEIGHTS OF PALMS SHALL BE THE HEIGHT FROM TOP OF ROOT BALL TO BOTTOM OF LIVE FRONDS. 6. PALM TREES TO BE PROPERLY WATERED IN A SOIL PROPERLY TAMPED AROUND THE ROOT BALL WHEN PLANTING. DO NOT LEAVE ANY VOIDS OF SOIL AROUND ROOT BALLS. 7. PALM TREES SHALL BE PLANTED VERTICALLY, UNLESS NOTED ON THE PLAN. 8. TRUNKS SHOULD BE ROUGHT WITH FRONDS BASES STILL SECURELY ATTACHED. 9. TRUNKS MAY NOT BE TOTALLY SKINNED UNLESS NOTED ON PLAN. 10. TRUNK BASES MAY BE SKINNED TO A MAXIMUM HEIGHT OF 3'-4" (TALLER PALM 6'-0"). 11. SKINNED AREAS ABOVE THE 6'-0" MARK WILL BE ACCEPTED, AT THE DIRECTION OF THE LANDSCAPE DESIGNER. 12. CARE SHOULD BE EXERCISED IN THE CABLING DURING TRANSPORT AND PLANTING SO AS NOT TO DAMAGE BARK. 13. SEVERE CRACKING OR HOLED IN THE BASAL TRUNK AREA WILL BOT BE ACCEPTABLE. 14. ONE INITIAL WATERING WILL BE PERFORMED BY SUBCONTRACTOR. BASIN WILL BE LEFT ON EACH PALM SO SUBSEQUENT WATERING CAN BE PERFORMED BY OTHERS. BASIN TO BE REMOVED DURING FINISH GRADING. 15. SUBCONTRACTOR TO UNTIE FROND TOPS (60) DAYS AFTER PLANTING. 16. PALM TREES SHALL BE PLANTED A MINIMUM OF 18" AWAY FROM BUILDING EAVES. 17. IT IS RECOMMENDED THAT ANY PALM TREE PLANTED WITHIN 5'-0" OF ANY WALKWAY, WALL, OR STRUCTURE BE PLANTED WITH DEEP ROOT BARRIER TO A DEPTH OF 2'-0" MINIMUM. 18. WASHINGTONIA ROBUSTA TRUNKS ARE TO HAVE A MINIMUM DIAMETER OF 14" MEASURED 4'-0" HIGH. 19. NO PALM TREE SHALL BE OUT OF THE ORIGINAL GROUND FOR MORE THAN (48) HOURS PRIOR TO PLANTING. PLANTING NOTES 1. BEFORE ANY PLANTS ARE PLANTED, ALL PLANTING AREAS MUST BE GRADED IN AN ACCEPTABLE MANNER TO ASSURE POSITIVE DRAINAGE PER THE DRADING NOTES. 2. WHERE CIRCUMSTANCES PERMIT, TREES TO BE PLANTED NO CLOSER THAN 18" TO AN EDGE OF HARDSCAPE. 3. REMOVE ALL STAKES FROM VINES. 4. PLANTING MATERIAL THAT IS ACCILMATED TO THE COACHELLA VALLEY MUST BE USED WHENEVER POSSIBLE. 5. WHEN TYING VINES OR ESPALIERS, WIRES SHOULD BE SPACED AS FOLLOWS: 1ST (2) AT 1'-6" APART FROM FINISHED GRADE, THE NEXT (3) AT 1'-0" APART TO MAKE THE TOOP WIRE AT 6'-0" ABOVE FINISHED GRADE. WIRES SHOULD BE A MINIMUM OF 8'-0" LONG CENTERE ON PLANTS. WHEN VINE OR SPALIERS ARE CLOSER THAN 10'-0" APART, USE A CONTINUOUS WIRE BETWEEN BOTH PLANTS.. 6. PLANT MATERIAL LISTED ON LEGEND MAY OR MAY NOT HAVE BEEN APPROVED BY THE AGRICULTURAL COMMISSIONER'S OFFICE. LANDSCAPE CONTRATOR TO CONTACT THE DEVELOPER FOR STATUS OF AGRUCULTURAL COMISSIONER'S APPROVAL OR DENIAL. PLANT MATIERIAL NOT CONFORMING WITH QUARANTINE LAWS MAY BE DETROYED AND CIVIL ACTION TAKEN. ALL PLANT MATERIAL IS SUBJECT TO INSPECTION AT THE DISCRETION OF THE AGRICULTURAL COMMISSIONER'S OFFICE. ALL PLANT MATERIAL MUST BE FREE RED SCALE (AONIDIELLA AURANTII). 7. NO SHRUBS ARE TO BE PLANTED WITHIN 18" OF HARDSCAPE, MEASURED FROM CENTER OF SHRUB. DEEP ROOT BARRIER APPLICATION 1. PREPARE THE INITIAL PLANTING HOLE AS ILLUSTRATED ON PLANTING NOTES. IT'S BASED UPON THE COMBINATION OF DESIRE BARRIER DIAMETER AND DEPTH. CONSIDER IF DRAINAGE DEVICES OR AMENDMENTS ARE NEEDED TO CORRECT ANY ADVERSE SOIL OR PLANTING CONDTIONS IN THE BACKFILL AREA. 2. ASSEMBLE THE APPROPRATE NUMBER OF DEEP ROOT UNIVERSAL BARRIER PANELS. THE VERTICAL ROOT DEFLECTING RIBS ON THE PANEL MUST FACE INWARD, TOWARD THE ROOT BALL. THIS IS VERY IMPORTANT, OTHERWISE THE ROOTS WILL BECOME GIRDLED BY TRAVELING AROUND THE SMOOTH WALLED SURFACE. 3. NEXT PLACE THE BARRIER IN THE CENTER OF THE PLANTING HOLE, KEEPING IN MIND THAT THE DOUBLE TOP EDGE OF THE BARRIER SHULD BE POSITIONED APPROXIMATELY 1/2" ABOVE GRADE. THIS HELPS RETARD POTENTIAL ROOT OVERGROWTH WHICH CAN LEAD TO UPROOTED HARDSCAPES. 4. BACKFILL AND COMPACT WITH SOIL INSIDE THE BARRIER TO THE LEVEL WHERE THE BOTTOM OF THE ROOT BALL APPROXIMATELY 1" ABOVE GRADE. 5. REMOVE THE TREE FROM ITS CONTAINER, OR CUT AWAY THE TOP PORTION OF BURLAP AND POSITION IN THE CENTER OF THE BARRIER. COMPLETE THE BACKFILL OF THE SOIL. DISTRIBUTE EVENLY TO MAINTAIN THE SHAPE OF THE BARRIER AND COMPACT THE BACKFILL EVERY 4"-6". ROOTS WILL DIE QUICKLY IF LEFT EXPOSED TOT HE ELEMENTS SO KEEP EXPOSURE OF THE ROOTS TO A MINIMUM. 6. IF STOKING OF GUYING IS REQURED, IT IS RECOMMENDED OF USING THE SOFT, SAFE AND ECONOMICAL ALTERNATIVE TO TRADITIONAL WIRE AND HOSE, ARBORTIE(SEE WWW.DEEPROOT.COM FOR DETAILS) 7. IF THE TREE(S) WILL BE SUBJECT TO MAINTENANCE WORK SUCH AS LAWN MOWING OR WEED TRIMMING IT IS RECOMMENDED TO INSTALL THE ARBORGARD+ TREE TRUNK PROTECTOR WHICH IS PLACED AROUND THE BASE OF YOUNG TREES TO PROTECT THEM FROM DAMAGE BY WEED TRIMMERS, LAWN MOWERS AND SMALL RODENTS. 8. WATER AND FOLLOW TREE MAINTENANCE PRACTICES. 9. TREES DO REQUIRE CARE AND NURTURING AFTER PLANTING. CONSULT WITH YOUR LOCAL SUPPLIER FOR PROPER CARE PROCEDURES FOR THE SPECIES YOU ARE PLANTING. THE PLANTING INSTRUCTION NOTED ABOVE ARE BY NO MEANS A COMPREHENSIVE GUIDE. RATHER THEY ARE GENERAL GUIDELINES TO PLANTING WITH DEEPROOT BARRIERS AND A SURVEY OF CURRENT PLANTING METHODS. CONDITIONS WILL VARY HOWVER AND IT IS RECOMMENDED THAT AN ARBORIST BE CONSULTED BEFORE PLANTING. ADDITIONAL INFORMATION IS AVAILABLE AT WWW.DEEPROOT.COM NOTE: NO PERMANENT STRUCTURES OR TREES WITHIN CVWD AND/OR USBR EASEMENTS. CVWD WILL NOT BE RESPONSIBLE FOR DAMAGE OR REPLACEMENT OF ANY SURFACE IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO, DECORATIVE CONCRETE, LANDSCAPING, CURB, GUTTER, SIDEWALKS, PLANTERS, GATES AND RELATED IMPROVEMENTS INSTALLED WITHING CVWD AND/OR USBR EASEMENTS NO TREES SHALL BE INSTALLED WITHIN 15ft OF A CVWD AND/OR USBR PIPELINE. SURFACE IMPROVEMENTS MAY BE INSTALLED WITHIN CVWD AND/OR USBR EASEMENT ONLY UPON THE PRIOR CONSENT OF CVWD, WHICH CONSENT MAY BE GRANTED OR DENIED AT CVWD'S SOLE DISCRETION. IN THE EVENT OF SUCH CONSENT, THEN A NON-INTERFERENCE REVIEW LETTER (NIRL) MAY APPLY PER SECTION 3.4 OR CVWD'S DEVELOPMENT DESIGN MANUAL. DRAINAGE STATEMENT FOR STAYBRIDGE SUITES TECHNOLOGY DRIVE PALM DESERT, CALIFORNIA PREPARED BY: ACE DESIGN LLC, 1024 IRON POINT ROAD, SUITE 1046 FOLSOM, CA 95630 DECEMBER 02, 2022 2 TABLE OF CONTENTS 1. INTRODUCTION: ....................................................................................................................... 3 2. PURPOSE OF THE DRAINAGE STATEMENT: .................................................................... 3 3.CONFORMANCE STATEMENT: ............................................................................................. 3 4. TOPOGRAPHY: ........................................................................................................................... 3 5. FEMA FLOODPLAIN INFORMATION: ................................................................................. 4 6. RAINDALL DEPTH: ................................................................................................................... 4 7. ON-SITE DRAINAGE AND RETENTION: .............................................................................. 4 8. STORMWATER QUALITY: ...................................................................................................... 5 APPENDIX 1 – VICINITY MAP APPENDIX 2 – FIRM MAP APPENDIX 3 – NOAA ATLAS 14 APPENDIX 4 – GRADING PLAN APPENDIX 5 – RETENTION BASIN STORAGE PLAN APPENDIX 6 – REFERENCE DRAINAGE STUDY – PAGE 75 & COMPLETE STUDY 3 1. INTRODUCTION: This report is prepared for 1.92-acre area site, located on the west of Technology Drive, North of the intersection of Technology Drive and Gerald Ford Drive in the City of Palm Desert, River Side County. The Hydrology for the site has been studied earlier in “Final Hydrology Report” prepared by MSA Engineers, Inc. for a 3.90-acre site consisting of Staybridge Suites (1.92-acre Project site) and Holiday Inn Express site (1.98 acre) on south. The project site will have access from Technology Drive. The site is designated by APN 694-190-085. Refer Appendix 1 Vicinity Map submitted with this report. The purpose of this report is to summarize the retention basin and storm water quality storage volume required for the Staybridge Suites Site as proposed in “Final Hydrology Report” prepared by MSA Engineers, Inc. for both Holiday Inn Express & Staybridge Hotel site. 2. PURPOSE OF THE DRAINAGE STATEMENT: The Site Plan for 1.92-acre site proposes to develop 96 Room Staybridge Suites hotel, parking spaces and driveway on this site. This hotel will be constructed north of Holiday Inn Express Hotel. The purpose of this statement is to review the reference drainage study and its calculations. Issue conformance statement (in case study and calculations are acceptable) and summarize the retention storage required for the runoff generated by the project site as calculated in the approved drainage study. 3. CONFORMANCE STATEMENT: The “Final Hydrology Report” prepared by MSA Engineers, Inc. for both sites (Staybridge Suites and Holiday Inn Express site) has been reviewed and ACE Design conforms to the runoff, retention basin and WQMP volume calculated for this site in the report. The total storm water runoff storage proposed in “Final Hydrology Report” is proposed to be maintained in this development. 4. TOPOGRAPHY: In present condition the site has slight desert vegetation and site has flat gradient. The site doesn’t receive flow from offsite basins. In present condition eastern part of Technology Drive ROW is developed. Technology Drive (Public) slopes from South to North and Northwest direction. 4 5.FEMA FLOODPLAIN INFORMATION: The site is in (FEMA) Flood Insurance Rate Map (FIRM) Community Panel Number 06065C1615G revised August 28, 2008. This Parcel lies within Zone X – Area of minimal flood hazard. Refer Appendix 2 for FIRM Map submitted with this report. 6.RAINDALL DEPTH: Precipitation depths for project site per NOAA atlas 14 are as follows: 2-year, 1-hour storm event – 0.35 inches 100-year, 1-hour storm event – 1.53 inches 100-year, 24-hour storm event – 4.49 inches Refer Appendix 3 for NOAA atlas 14 submitted with this report 7.ON-SITE DRAINAGE AND RETENTION: In “Final Hydrology Report” prepared by MSA Engineers, Inc., retention basins for 100-year, 24-hour storm event for complete 3.90-acre site have been proposed as there is no storm drainage facility in the Technology drive. The 1.92 acre Staybridge Suites site is divided into 2 drainage areas as described below: Onsite Area 1 (Drainage Area A - “Final Hydrology Report” – further divided into 2 Parts) – This 1.16-acre area is on the north of the site, and drains towards underground pipe and surface retention basin proposed along northern and eastern property line. This Underground basin is proposed to be connected by a pipe to surface basin. As per “Final Hydrology Report” prepared by MSA Engineers, Inc., a total retention of 8,049 cubic feet is required for this area for 100-year, 24-hour storm event. Retention of 8,126 cubic feet is provided (6,004 cubic feet in underground basin and 2,122 cubic in surface basin). However, in construction drawings the retention volume capacity has been increased to 8,593 cubic feet (6,004 cubic feet in underground basin and 2,589 cubic feet in surface basin). Impervious ratio of this area is same as compared to the ratio considered in “Final Hydrology Report” prepared by MSA Engineers, Inc., So, same retention storage volume is proposed to be provided. 5 Onsite Area 2 (Part of Drainage Area B - “Final Hydrology Report”) – This 0.76-acre area is on the south of the site and drains towards proposed above ground retention basin (shared with Holiday Inn Express site). This area is part of Drainage Area B measuring 1.80 acres, consisting 0.76 acre of Staybridge site and 1.04 acre of Holiday Inn Express site. Retention Volume for Drainage Area B (further divided into 4 Parts) - As per “Final Hydrology Report” prepared by MSA Engineers, Inc., a total retention volume of 11,457 cubic feet is required for this area for 100-year, 24-hour storm event. Retention of 11,526 cubic feet is provided (2,803 cubic feet in underground basin and 8,723 cubic in surface basin). The retention basins for this area will be provided along with the development of Holiday Inn Express site. Refer Appendix 4 for sheet 2-Grading plan, and Appendix 5 for sheet 3-Retention Basin Storage Plan for conceptual grading, location of the retention basins and Onsite Area. Also refer page number 75 of “Final Hydrology Report” for summary of the proposed retention basins. Refer table below for retention volume provided: SR. NO. DRAINAGE AREA AREA IN ACRE RETENTION VOLUME REQUIRED IN CFT RETENTION VOLUME PROVIDED IN CFT 1 Onsite-1 (Drainage Area A) 1.16 8,049 8,593 2 Onsite-2 (Part of Drainage Area B) 0.76 11,457 11,526 3 Holiday Inn Express Site Area (Part of Drainage Area B) 1.04 Total 2.96 19,506 20,119 8.STORMWATER QUALITY: Per “Final Hydrology Report” prepared by MSA Engineers, Inc., storm water quality volume is calculated using the Riverside County – Whitewater River Region Water Quality plan. 6 The proposed retention volume for both onsite areas as given in table above has more volume than the required water quality volume, so the necessary storm water treatment is provided by the retention basins. Refer table below for Water Quality Volume calculated in “Final Hydrology Report” prepared by MSA Engineers, Inc. The capacity of retention basin in drainage area is increase to 8,593 cubic feet as compared to 8,126 cubic feet in the original drainage report. SR. NO. DRAINAGE AREA AREA IN ACRE RETENTION VOLUME REQUIRED IN CFT TREATMENT PROVIDED BY RETENTION VOLUME PROVIDED IN CFT 1 Onsite-1 (Drainage Area A) 1.16 994 8,593 2 Onsite-2 (Part of Drainage Area B) 0.76 1,503 11,526 3 Holiday Inn Express Site Area (Part of Drainage Area B) 1.04 Total 2.96 2,497 20,119 National Flood Hazard Layer FIRMette 0 500 1,000 1,500 2,000250 Feet Ü SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT SPECIAL FLOOD HAZARD AREAS Without Base Flood Elevation (BFE) Zone A, V, A99 With BFE or DepthZone AE, AO, AH, VE, AR Regulatory Floodway 0.2% Annual Chance Flood Hazard, Areas of 1% annual chance flood with average depth less than one foot or with drainage areas of less than one square mileZone X Future Conditions 1% Annual Chance Flood HazardZone X Area with Reduced Flood Risk due to Levee. See Notes.Zone X Area with Flood Risk due to LeveeZone D NO SCREEN Area of Minimal Flood Hazard Zone X Area of Undetermined Flood HazardZone D Channel, Culvert, or Storm Sewer Levee, Dike, or Floodwall Cross Sections with 1% Annual Chance 17.5 Water Surface Elevation Coastal Transect Coastal Transect Baseline Profile Baseline Hydrographic Feature Base Flood Elevation Line (BFE) Effective LOMRs Limit of Study Jurisdiction Boundary Digital Data Available No Digital Data Available Unmapped This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below. The basemap shown complies with FEMA's basemap accuracy standards The flood hazard information is derived directly from the authoritative NFHL web services provided by FEMA. This map was exported on 7/2/2021 at 1:39 AM and does not reflect changes or amendments subsequent to this date and time. The NFHL and effective information may change or become superseded by new data over time. This map image is void if the one or more of the following map elements do not appear: basemap imagery, flood zone labels, legend, scale bar, map creation date, community identifiers, FIRM panel number, and FIRM effective date. Map images for unmapped and unmodernized areas cannot be used for regulatory purposes. Legend OTHER AREAS OF FLOOD HAZARD OTHER AREAS GENERAL STRUCTURES OTHER FEATURES MAP PANELS 8 B 20.2 The pin displayed on the map is an approximate point selected by the user and does not represent an authoritative property location. 1:6,000 116°21'46"W 33°47'20"N 116°21'9"W 33°46'51"N Basemap: USGS National Map: Orthoimagery: Data refreshed October, 2020 T E C H N O L O G Y D R I V E T E C H N O L O G Y D R I V ENOPARK ING STAYBRIDGE SUITES4 STORY96 ROOMS PATIO4 STORY POOL595 SQ.FTPOOLEQUIPMENTHOLIDAY INN EXPRESS HOTEL4 STORY/ 96 ROOMSPARCEL-2BUILDING BBUILDING APOOLEQUIPMENTSTAIR 1UPUPTECHNOLOGY DRIVEPROJECT SITEPUBLICLand Planning Civil Engineering Architectural Design Structural EngineeringACE Design LLCACE Design LLCFOLSOM, CA 956301024 IRON POINT ROAD, SUITE 1046Phone: (702) 396-5113, Fax: (702)446-8155 1%GERALDFORD DRIVECITY OFPALM DESERTFRANK SINAIRA DRIVETECHNOLOGYDRIVEVARNER ROADGERALDFOOD DRIVEPORTOLA AVENUE COOK STREET PROJECT2"(MIN.)4" CONCRETE SIDEWALK T E C H N O L O G Y D R I V E T E C H N O L O G Y D R I V ENOPARK ING STAYBRIDGE SUITE S 4 STORY96 ROOMS P A T I O 4 STORY POOL595 SQ.FTPOOLEQUIPMENT HOLIDAY INN EXPRESS HOTEL4 STORY/ 96 ROOMSPARCEL-2BUILDING BBUILDING APOOLEQUIPMENTSTAIR 1UPUPCONTECH UNDERGROUND 60" CORRUGATED METAL PIPESTORMWATER RETENTION SYSTEM TYPICAL SECTION1Land Planning Civil Engineering Architectural Design Structural EngineeringACE Design LLCACE Design LLCFOLSOM, CA 956301024 IRON POINT ROAD, SUITE 1046Phone: (702) 396-5113, Fax: (702)446-8155 GERALDFORD DRIVECITY OFPALM DESERTFRANK SINAIRA DRIVETECHNOLOGYDRIVEVARNER ROADGERALDFOOD DRIVEPORTOLA AVENUE COOK STREET PROJECT N O P A R K IN G N O P A R K IN G N O P A R K IN G NOPARKINGNOPARKINGNOPARKINGTECHNOLOGYDRIVEH O TELFF=170.37PE=169.9 R:\2438\ACAD\Hydrology\Final\2438 FINAL SUH HYDROLOGY EXHIBIT.dwg, 6/4/2019 1:36:47 PM, jsanagustin, MSA Consulting, Inc. SHEET SHEETS 1 OF 1 N.T.S. VICINITY MAPPORTOLA AVENUE CITY OFPALM DESERT FRANK SINATRA DRIVE GERALD GERALD FO RD DRIVE VARNER RO A D I-10 COOK STREET FORD DRIVE TEC H N OLO G Y DRIVE IN THE CITY OF DESERT HOT SPRINGS, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA PARCEL MAP 37488FINAL HYDROLOGY EXHIBIT RCFCD SYNTHETIC UNIT (SHORTCUT METHOD) DATA TABLE ASSESSOR'S PARCEL NUMBERS: EXHIBIT DATE: JUNE 4, 2019 SOURCE OF TOPOGRAPHY: ADDRESS: DATE OF TOPOGRAPHY:TELEPHONE: PUBLIC UTILITY PURVEYORS: SOUTHERN CALIFORNIA EDISON SOUTHERN CALIFORNIA GAS COMPANY VERIZON COMPANY COACHELLA VALLEY WATER DISTRICT TIME WARNER CABLE COACHELLA VALLEY WATER DISTRICT UNDERGROUND SERVICE ALERT EXISTING ZONING: PROPOSED ZONING: EXISTING GENERAL PLAN LAND USE: PROPOSED GENERAL PLAN LAND USE: PLANNED COMMERCIAL LAND USE DESCRIPTION:ACREAGE: EXISTING EASEMENT NOTES: FEMA FLOOD ZONE DESIGNATION: EXHIBIT PREPARER: ADDRESS: MSA CONSULTING, INC. 34200 BOB HOPE DRIVERANCHO MIRAGE, CALIFORNIA 92270 CONTACT:JULIAN A. DE LA TORRE (PE C43880)TELEPHONE:(760) 320-9811 APPLICANT / ADDRESS: CONTACT:TELEPHONE: REVISIONS NO.DATE LIQUEFACTION:MODERATE LIQUEFACTION ZONE NOTES:1. 2. LEGAL DESCRIPTION: (760) 324-4991 (800) 427-2200 (800) 483-5000 (760) 398-2651 (760) 340-1312 (760) 398-2651 (800) 227-2600 DESCRIPTION LAND OWNER: THIS MAP INCLUDES THE ENTIRE CONTIGUOUS OWNERSHIP OF THE LAND DIVIDER. THERE ARE NO EXISTING DWELLINGS, BUILDINGS, OR OTHER STRUCTURES KNOWN ONTHIS PROPERTY. ELECTRIC GAS TELEPHONE WATER CABLE SEWER USA 694-190-085 & A PORTION OF 694-190-086 DIGITAL MAPPING, INC. 21062 BROOKHURST STREET - SUITE 101HUNTINGTON BEACH, CALIFORNIA 92646 01-31-13 / 06-22-14 (714) 968-5459 EXISTING GROSS ACREAGE:3.92 AC. 44530 SAN PABLO AVENUE - SUITE 200PALM DESERT, CALIFORNIA 92260 DAVID PREST (760) 779-5393 PROPOSED PARCEL NO. 2 1.98 AC. TOWNSHIP 4 SOUTH, RANGE 6 EAST, SAN BERNARDINO MERIDIAN.PARCEL 5 & A PORTION OF PARCEL 6 OF PM 239/9-15 OF THE NORTH 1/2 OF SECTION 33, 1.89 AC.PROPOSED PARCEL NO. 1 AN EASEMENT IN FAVOR OF VERIZON CALIFORNIA INC. FOR PUBLIC UTILITIES ANDINCIDENTAL PURPOSES, RECORDED SEPTEMBER 13, 2016 AS INSTRUMENT NO. 2016-0396230 PROPOSED RIGHT OF WAY DEDICATION (TECHNOLOGY DRIVE):0.05 AC. PROPOSED NET ACREAGE:3.87 AC. PREST VUKSIC ARCHITECTS OF OFFICIAL RECORDS. (TO BE RELOCATED)1 PLANNED COMMERCIAL NEIGHBORHOOD CENTER NEIGHBORHOOD CENTER ZONE X - AREAS OF MINIMAL FLOOD HAZARD AS SHOWN ON RIVERSIDE COUNTY, CALIFORNIA, FLOOD INSURANCE RATE MAPS,COMMUNITY PANEL MAP NUMBERS 06065C1615GEFFECTIVE DATE: AUGUST 28, 2008.7'3.5'3.5'7' 3.5'3.5' 1'1'1'1'1 1 N O P A R K IN G N O P A R K IN G N O P A R K IN G NOPARKINGNOPARKINGNOPARKINGTECHNOLOGYDRIVEH O TELFF=170.37PE=169.9 R:\2438\ACAD\Hydrology\Final\2438 FINAL SUH HYDROLOGY EXHIBIT.dwg, 6/4/2019 1:36:47 PM, jsanagustin, MSA Consulting, Inc. SHEET SHEETS 1 OF 1 N.T.S. VICINITY MAPPORTOLA AVENUE CITY OFPALM DESERT FRANK SINATRA DRIVE GERALD GERALD FO RD DRIVE VARNER RO A D I-10 COOK STREET FORD DRIVE TEC H N OLO G Y DRIVE IN THE CITY OF DESERT HOT SPRINGS, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA PARCEL MAP 37488FINAL HYDROLOGY EXHIBIT RCFCD SYNTHETIC UNIT (SHORTCUT METHOD) DATA TABLE ASSESSOR'S PARCEL NUMBERS: EXHIBIT DATE: JUNE 4, 2019 SOURCE OF TOPOGRAPHY: ADDRESS: DATE OF TOPOGRAPHY:TELEPHONE: PUBLIC UTILITY PURVEYORS: SOUTHERN CALIFORNIA EDISON SOUTHERN CALIFORNIA GAS COMPANY VERIZON COMPANY COACHELLA VALLEY WATER DISTRICT TIME WARNER CABLE COACHELLA VALLEY WATER DISTRICT UNDERGROUND SERVICE ALERT EXISTING ZONING: PROPOSED ZONING: EXISTING GENERAL PLAN LAND USE: PROPOSED GENERAL PLAN LAND USE: PLANNED COMMERCIAL LAND USE DESCRIPTION:ACREAGE: EXISTING EASEMENT NOTES: FEMA FLOOD ZONE DESIGNATION: EXHIBIT PREPARER: ADDRESS: MSA CONSULTING, INC. 34200 BOB HOPE DRIVERANCHO MIRAGE, CALIFORNIA 92270 CONTACT:JULIAN A. DE LA TORRE (PE C43880)TELEPHONE:(760) 320-9811 APPLICANT / ADDRESS: CONTACT:TELEPHONE: REVISIONS NO.DATE LIQUEFACTION:MODERATE LIQUEFACTION ZONE NOTES:1. 2. LEGAL DESCRIPTION: (760) 324-4991 (800) 427-2200 (800) 483-5000 (760) 398-2651 (760) 340-1312 (760) 398-2651 (800) 227-2600 DESCRIPTION LAND OWNER: THIS MAP INCLUDES THE ENTIRE CONTIGUOUS OWNERSHIP OF THE LAND DIVIDER. THERE ARE NO EXISTING DWELLINGS, BUILDINGS, OR OTHER STRUCTURES KNOWN ONTHIS PROPERTY. ELECTRIC GAS TELEPHONE WATER CABLE SEWER USA 694-190-085 & A PORTION OF 694-190-086 DIGITAL MAPPING, INC. 21062 BROOKHURST STREET - SUITE 101HUNTINGTON BEACH, CALIFORNIA 92646 01-31-13 / 06-22-14 (714) 968-5459 EXISTING GROSS ACREAGE:3.92 AC. 44530 SAN PABLO AVENUE - SUITE 200PALM DESERT, CALIFORNIA 92260 DAVID PREST (760) 779-5393 PROPOSED PARCEL NO. 2 1.98 AC. TOWNSHIP 4 SOUTH, RANGE 6 EAST, SAN BERNARDINO MERIDIAN.PARCEL 5 & A PORTION OF PARCEL 6 OF PM 239/9-15 OF THE NORTH 1/2 OF SECTION 33, 1.89 AC.PROPOSED PARCEL NO. 1 AN EASEMENT IN FAVOR OF VERIZON CALIFORNIA INC. FOR PUBLIC UTILITIES ANDINCIDENTAL PURPOSES, RECORDED SEPTEMBER 13, 2016 AS INSTRUMENT NO. 2016-0396230 PROPOSED RIGHT OF WAY DEDICATION (TECHNOLOGY DRIVE):0.05 AC. PROPOSED NET ACREAGE:3.87 AC. PREST VUKSIC ARCHITECTS OF OFFICIAL RECORDS. (TO BE RELOCATED)1 PLANNED COMMERCIAL NEIGHBORHOOD CENTER NEIGHBORHOOD CENTER ZONE X - AREAS OF MINIMAL FLOOD HAZARD AS SHOWN ON RIVERSIDE COUNTY, CALIFORNIA, FLOOD INSURANCE RATE MAPS,COMMUNITY PANEL MAP NUMBERS 06065C1615GEFFECTIVE DATE: AUGUST 28, 2008.7'3.5'3.5'7' 3.5'3.5' 1'1'1'1'1 1 TECHNOLOGYDRIVEH O TELFF=170.37PE=169.9 POOL WS= 170.00 N O PA R K IN G N O PA R K IN G N O PA R K IN G NOPARKINGNOPARKINGNOPARKINGR:\2438\ACAD\Hydrology\Final\2438 FINAL RATIONAL HYDROLOGY EXHIBIT.dwg, 6/4/2019 1:31:00 PM, jsanagustin, MSA Consulting, Inc. SHEET SHEETS 1 OF 1 IN THE CITY OF DESERT HOT SPRINGS, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA PARCEL MAP 37488FINAL HYDROLOGY EXHIBIT RCFCD RATIONAL METHOD ANALYSES N.T.S. VICINITY MAPPORTOLA AVENUE CITY OFPALM DESERT FRANK SINATRA DRIVE GERALD GERALD FO RD DRIVE VARNER RO A D I-10 COOK STREET FORD DRIVE TEC H N OLO GY DRIVE DATA TABLE ASSESSOR'S PARCEL NUMBERS: EXHIBIT DATE: JUNE 4, 2019 SOURCE OF TOPOGRAPHY: ADDRESS: DATE OF TOPOGRAPHY:TELEPHONE: PUBLIC UTILITY PURVEYORS: SOUTHERN CALIFORNIA EDISON SOUTHERN CALIFORNIA GAS COMPANY VERIZON COMPANY COACHELLA VALLEY WATER DISTRICT TIME WARNER CABLE COACHELLA VALLEY WATER DISTRICT UNDERGROUND SERVICE ALERT EXISTING ZONING: PROPOSED ZONING: EXISTING GENERAL PLAN LAND USE: PROPOSED GENERAL PLAN LAND USE: PLANNED COMMERCIAL LAND USE DESCRIPTION:ACREAGE: EXISTING EASEMENT NOTES: FEMA FLOOD ZONE DESIGNATION: EXHIBIT PREPARER: ADDRESS: MSA CONSULTING, INC. 34200 BOB HOPE DRIVERANCHO MIRAGE, CALIFORNIA 92270 CONTACT:JULIAN A. DE LA TORRE (PE C43880)TELEPHONE:(760) 320-9811 APPLICANT / ADDRESS: CONTACT:TELEPHONE: REVISIONS NO.DATE LIQUEFACTION:MODERATE LIQUEFACTION ZONE NOTES:1. 2. LEGAL DESCRIPTION: (760) 324-4991 (800) 427-2200 (800) 483-5000 (760) 398-2651 (760) 340-1312 (760) 398-2651 (800) 227-2600 DESCRIPTION LAND OWNER: THIS MAP INCLUDES THE ENTIRE CONTIGUOUS OWNERSHIP OF THE LAND DIVIDER. THERE ARE NO EXISTING DWELLINGS, BUILDINGS, OR OTHER STRUCTURES KNOWN ONTHIS PROPERTY. ELECTRIC GAS TELEPHONE WATER CABLE SEWER USA 694-190-085 & A PORTION OF 694-190-086 DIGITAL MAPPING, INC. 21062 BROOKHURST STREET - SUITE 101HUNTINGTON BEACH, CALIFORNIA 92646 01-31-13 / 06-22-14 (714) 968-5459 EXISTING GROSS ACREAGE:3.92 AC. 44530 SAN PABLO AVENUE - SUITE 200PALM DESERT, CALIFORNIA 92260 DAVID PREST (760) 779-5393 PROPOSED PARCEL NO. 2 1.98 AC. TOWNSHIP 4 SOUTH, RANGE 6 EAST, SAN BERNARDINO MERIDIAN.PARCEL 5 & A PORTION OF PARCEL 6 OF PM 239/9-15 OF THE NORTH 1/2 OF SECTION 33, 1.89 AC.PROPOSED PARCEL NO. 1 AN EASEMENT IN FAVOR OF VERIZON CALIFORNIA INC. FOR PUBLIC UTILITIES ANDINCIDENTAL PURPOSES, RECORDED SEPTEMBER 13, 2016 AS INSTRUMENT NO. 2016-0396230 PROPOSED RIGHT OF WAY DEDICATION (TECHNOLOGY DRIVE):0.05 AC. PROPOSED NET ACREAGE:3.87 AC. PREST VUKSIC ARCHITECTS OF OFFICIAL RECORDS. (TO BE RELOCATED)1 PLANNED COMMERCIAL NEIGHBORHOOD CENTER NEIGHBORHOOD CENTER ZONE X - AREAS OF MINIMAL FLOOD HAZARD AS SHOWN ON RIVERSIDE COUNTY, CALIFORNIA, FLOOD INSURANCE RATE MAPS,COMMUNITY PANEL MAP NUMBERS 06065C1615GEFFECTIVE DATE: AUGUST 28, 2008. 1 1 N O P A R K IN G N O P A R K IN G N O P A R K IN G NOPARKINGNOPARKINGNOPARKINGFU TU REH O TELFF=170.37PE=169.9 POOL WS= 170.00 R:\2438\ACAD\Grading\Preliminary\2438 PRELIMINARY GRADING PLAN.dwg, 6/4/2019 1:42:20 PM, jsanagustin, MSA Consulting, Inc. SHEET SHEETS 1 OF 1 DATA TABLE ASSESSOR'S PARCEL NUMBERS: EXHIBIT DATE: JUNE 4, 2019 SOURCE OF TOPOGRAPHY: ADDRESS: DATE OF TOPOGRAPHY:TELEPHONE: PUBLIC UTILITY PURVEYORS: SOUTHERN CALIFORNIA EDISON SOUTHERN CALIFORNIA GAS COMPANY VERIZON COMPANY COACHELLA VALLEY WATER DISTRICT TIME WARNER CABLE COACHELLA VALLEY WATER DISTRICT UNDERGROUND SERVICE ALERT EXISTING ZONING: PROPOSED ZONING: EXISTING GENERAL PLAN LAND USE: PROPOSED GENERAL PLAN LAND USE: PLANNED COMMERCIAL LAND USE DESCRIPTION:ACREAGE: EXISTING EASEMENT NOTES: FEMA FLOOD ZONE DESIGNATION: EXHIBIT PREPARER: ADDRESS: MSA CONSULTING, INC. 34200 BOB HOPE DRIVERANCHO MIRAGE, CALIFORNIA 92270 CONTACT:JULIAN A. DE LA TORRE (PE C43880)TELEPHONE:(760) 320-9811 APPLICANT / ADDRESS: CONTACT:TELEPHONE: REVISIONS NO.DATE LIQUEFACTION:MODERATE LIQUEFACTION ZONE NOTES:1. 2. IN THE CITY OF PALM DESERT, THE COUNTY OF RIVERSIDE, STATE OF CALIFORNIA LEGAL DESCRIPTION: (760) 324-4991 (800) 427-2200 (800) 483-5000 (760) 398-2651 (760) 340-1312 (760) 398-2651 (800) 227-2600 DESCRIPTION EAST NORTH SOUTH WEST CENTERLINE EASEMENT EXISTING NUMBER PROPOSED RIGHT OF WAY TYPICAL (E) (N) (S) (W) C/L ESMT. EX. NO. PROP. R/W TYP. ABBREVIATIONS P.U.E.PUBLIC UTILITY EASEMENT ACREAGEAC CURB AND GUTTERC&G ASSESSORS PARCEL NUMBERAPN E/P EDGE OF PAVEMENT SF SQUARE FEET RADIUSR STANDARDSTD. A.C.ASPHALT CONCRETE P/L PROPERTY LINE N.T.S.NOT TO SCALE MIN.MINIMUM MAX.MAXIMUM EXISTING OVERHEAD TELEPHONE EXISTING IRRIGATION EXISTING GAS EXISTING SEWER EXISTING RIGHT OF WAY EXISTING EASEMENT EXISTING ELECTRIC PROPOSED CURB PROPOSED EASEMENT EXISTING CITY / COUNTY LIMITS EXISTING SEWER FORCE MAIN EXISTING IRRIGATION DRAIN LINE EXISTING CABLE EXISTING CONTOURS EXISTING SPOT ELEVATIONS LEGEND EXISTING WATER EXISTING EASEMENT DELTA EXISTING LOT LINE PROPOSED RIGHT OF WAY EXISTING TELEPHONE R-L LOW DENSITY (RESIDENTIAL) UG UNDERGROUND BOUNDARYBNDRY OVERHEADO/H OPEN SPACE / PARKSOS/PP EXISTING EDGE OF PAVEMENT PAGEPG. M.B.MAP BOOK PROPOSED AND EXISTING CENTER LINE TENTATIVE TRACT MAP BOUNDARY EXISTING TRACT MAP BOUNDARY LAND OWNER: THIS MAP INCLUDES THE ENTIRE CONTIGUOUS OWNERSHIP OF THE LAND DIVIDER. THERE ARE NO EXISTING DWELLINGS, BUILDINGS, OR OTHER STRUCTURES KNOWN ONTHIS PROPERTY. ELECTRIC GAS TELEPHONE WATER CABLE SEWER USA N.T.S. VICINITY MAPPORTOLA AVENUE CITY OFPALM DESERT FRANK SINATRA DRIVE GERALD GERALD FO RD DRIVE VARNER RO A D I-10 COOK STREET FORD DRIVE TEC HN OLO GY DRIVE PARCEL MAP NO. 37488 694-190-085 & A PORTION OF 694-190-086 DIGITAL MAPPING, INC. 21062 BROOKHURST STREET - SUITE 101HUNTINGTON BEACH, CALIFORNIA 92646 01-31-13 / 06-22-14 (714) 968-5459 EXISTING GROSS ACREAGE:3.92 AC. 44530 SAN PABLO AVENUE - SUITE 200PALM DESERT, CALIFORNIA 92260 DAVID PREST (760) 779-5393 PROPOSED PARCEL NO. 2 1.98 AC. TOWNSHIP 4 SOUTH, RANGE 6 EAST, SAN BERNARDINO MERIDIAN.PARCEL 5 & A PORTION OF PARCEL 6 OF PM 239/9-15 OF THE NORTH 1/2 OF SECTION 33, 1.89 AC.PROPOSED PARCEL NO. 1 AN EASEMENT IN FAVOR OF VERIZON CALIFORNIA INC. FOR PUBLIC UTILITIES ANDINCIDENTAL PURPOSES, RECORDED SEPTEMBER 13, 2016 AS INSTRUMENT NO. 2016-0396230 PROPOSED RIGHT OF WAY DEDICATION (TECHNOLOGY DRIVE):0.05 AC. PROPOSED NET ACREAGE:3.87 AC. PREST VUKSIC ARCHITECTS OF OFFICIAL RECORDS. (TO BE RELOCATED)1 PLANNED COMMERCIAL NEIGHBORHOOD CENTER NEIGHBORHOOD CENTER ZONE X - AREAS OF MINIMAL FLOOD HAZARD AS SHOWN ON RIVERSIDE COUNTY, CALIFORNIA, FLOOD INSURANCE RATE MAPS,COMMUNITY PANEL MAP NUMBERS 06065C1615GEFFECTIVE DATE: AUGUST 28, 2008. 12'12' SECTION A-A TECHNOLOGY DRIVE (COMMERCIAL INDUSTRIAL) 72' (ULTIMATE R/W) 6.5'12'8' 26' 36' (PUBLIC ROAD) N.T.S. 26' 6.5'3.5' 10' 3.5' 10' 36' 2% PROPOSED SIDEWALK 8' CL R/W PROP. TRAVEL LANE TRAVEL LANEPAINTED MEDIAN EXISTING SIDEWALK 12'12' SECTION B-B TECHNOLOGY DRIVE (COMMERCIAL INDUSTRIAL) 77' (ULTIMATE R/W) 6.5'12'8' 26' 36' 26' 10'3.5' 10'15' 41' 2% A.C. PAVEMENT OVER A.B. ADA WALK 8' CL R/W ULTIMATER/W PROP. TRAVEL LANE TRAVEL LANEPAINTED MEDIAN EXISTING SIDEWALK VARIES 36' TO 40'R/W EX. VARIES 32' TO 36'R/W EX. 1 PROPOSED A.C. PAVEMENT OVER A.B. EXISTING CURB AND EXISTING GUTTER A.C. PAVEMENT OVER A.B. PROPOSED A.C. PAVEMENT OVER A.B. EXISTING CURB AND EXISTING GUTTER CURB AND PROPOSED GUTTER 5' DRIVEWAY APPROACHA.C. PAVEMENT OVER A.B. PROPOSED PR.PROPOSED NOTE : SIDEWALK CROSS-SLOPE 1 CONCEPTUAL GRADING AND DRAINAGE PLAN 3 6 '36'36'R/W ULTIMATE VARIES 36' TO 40'R/W EX. VARIES 32' TO 36'R/W EX. (CITY STD. NO. 308) N.T.S. (CITY STD. NO. 308) (PUBLIC ROAD) 36' NOPARKINGNOPARKINGNOPARKINGN.T.S. VICINITY MAPPORTOLA AVENUE CITY OFPALM DESERT FRANK SINATRA DRIVE GERALD GERALD FO RD DRIVE V ARNER RO A D I-10 COOK STREET FORD DRIVE TEC HN OLO GY DRIVE R:\2438\ACAD\Grading\Precise\Phase 1\2438 PG 01.dwg, 6/4/2019 1:46:24 PM, jsanagustin, MSA Consulting, Inc. NOPARKINGNOPARKINGR:\2438\ACAD\Grading\Precise\Phase 1\2438 PG 02.dwg, 6/4/2019 1:47:03 PM, jsanagustin, MSA Consulting, Inc. NOPARKINGR:\2438\ACAD\Grading\Precise\Phase 1\2438 PG 03.dwg, 6/4/2019 1:47:32 PM, jsanagustin, MSA Consulting, Inc. R:\2438\ACAD\Grading\Precise\Phase 1\2438 PG 04.dwg, 6/4/2019 1:48:03 PM, jsanagustin, MSA Consulting, Inc. R:\2438\ACAD\Grading\Precise\Phase 1\2438 PG 05.dwg, 6/4/2019 1:48:34 PM, jsanagustin, MSA Consulting, Inc. MINIMUM FINE $250 ACCESSIBLEVAN R:\2438\ACAD\Grading\Precise\Phase 1\2438 PG 06.dwg, 6/4/2019 1:48:59 PM, jsanagustin, MSA Consulting, Inc. R:\2438\ACAD\Grading\Precise\Phase 1\2438 PG 07.dwg, 6/4/2019 1:49:24 PM, jsanagustin, MSA Consulting, Inc. ARCHITECTURAL REVIEW COMMISSION NOTICE OF ACTION November 10, 2021 ACE Design, LLC 2795 E. Bidwell St., Suite 100-318 Folsom, CA 95630 Subject: Preliminary review and discussion to provide architectural comments on the proposed four-story Staybridge Suites hotel. The Architectural Review Commission of the City of Palm Desert considered your request at its meeting of October 26, 2021: Design comments were provided by the Commission for the applicant’s consideration for Case No. MISC 21-0023. To view video or audio for the discussion on this item, including comments provided by the Commission, please visit the Architectural Review Commission Information Center website at, https://www.cityofpalmdesert.org/our- city/committees-and-commissions/architectural-review-commission-information-center. If you have any questions, please contact Associate Planner, Kevin Swartz, at (760) 346- 0611, Extension 485 or kswartz@cityofpalmdesert.org. Sincerely, ROSIE LUA, SECRETARY ARCHITECTURAL REVIEW COMMISSION cc: File CITY OF PALM DESERTATTENDANCE REPORTAdvisory Body: Architectural Review CommissionPrepared By:YearMonthDate 11‐Jan 25‐Jan 8‐Feb 22‐Feb 8‐Mar 22‐Mar 12‐Apr 26‐Apr 10‐May 24‐May 14‐Jun 28‐Jun 12‐Jul 26‐Jul 9‐Aug 23‐Aug 13‐Sep 27‐Sep 11‐Oct 25‐Oct 8‐Nov 22‐Nov 13‐Dec 27‐DecColvard, Dean WallacePPPPPPAP‐11Latkovic, NicholasPPPP‐PPPP PPP‐‐‐PPPPPPPP‐00McAuliffe, MichaelPPPP‐PPPA PPP‐‐‐PAPPPPPP‐22McIntosh, JamesPPPP‐PPAP PPA‐‐‐PPAPPAAP‐55Sanchez, FranciscoPPPPP P P‐00Vuksic, JohnPPPP‐PPPP PPP‐‐‐PPPPPPPA‐11Vacancy00Palm Desert Municipal Code 2.34.010:Twice Monthly: Six unexcused absences from regular meetings in any twelve‐month period shall constitute an automatic resignation of members holding office on boards that meet twice monthly.Total Unexcused AbsencesJan Feb Mar Apr May Jun Jul Aug Sep2022 2022 2022 2022 2022Total AbsencesOct Nov DecM. Gonzalez2022 20222022 2022 2022 2022 2022