Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_SOLR23-0603_M. Vargas - Plans
MODULE WATT: 400 W (32)PANASONIC EVPV400HK SYSTEM SIZE:12.80 KW DC (STC) :12.22 KW DC (PTC) :11.91 KW AC (CEC) (32)MICROINVERTERS: ENPHASE IQ8A-72-M-US AZIMUTH:180° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/29/2024 MICHELLE VARGAS RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:2/28/2023 SHEET NAME SHEET NUMBER 40750 AVENIDA ROSARIO PALM DESERT,CA,92260 PHONE:(760)898-3411 OCCUPANCY TYPE:V-B GROUP:R APN:622340018 SJ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 SCOPE OF WORK VICINITY MAP PROJECT SITE(33.7522151,-116.3838212) CODE COMPLIANCE GENERAL NOTES SHEET INDEX 32 x PANASONIC EVPV400HK ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 12.80 KW DC STC 12.22 KW DC PTC 11.91 KW AC CEC EQUIPMENT SUMMARY 32 PANASONIC EVPV400HK 32 ENPHASE IQ8A-72-M-US (32X349/1000=11.17 KW INVERTER OUTPUT) ROOF TILT:18° AZIMUTH:180° 1 STORY BUILDING 2022 CA BUILDING CODE 2022 CA PLUMBING CODE 2022 CA FIRE CODE 2022 CA RESIDENTIAL CODE 2022 CA MECHANICAL CODE 2022 CA ENERGY CODE 2022 CA ELECTRICAL CODE 2020 NATIONAL ELECTRICAL CODE 2022 ENERGY COMPLIANCE T-24 THIS PROJECT SHALL COMPLY WITH PV-1 COVER PAGE PV-2 PLOT PLAN PV-3 ROOF PLAN PV-4 ELECTRICAL LINE DIAGRAM PV-5 ATTACHMENT DETAIL PV-6A LIST OF PLACARDS PV-6B OPTIMIZERS CHART UL LISTED FOR ELECTRICAL AND FIRE SAFETY UL 1703 FOR MODULES AND UL 1741 FOR INVERTERS PER CITY SOLAR REQUIREMENTS NOTE: NO DISCHARGE OF ANY POLLUTANTS TO ANY STORM WATER DRAIN SYSTEM -SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. -THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND LOCAL UTILITY.UTILITY SHALL BE NOTIFIED PRIOR TO ACTIVATION OF SOLAR PHOTOVOLTAIC INSTALLATION. -ALL EXTERNAL CONDUIT AND FITTINGS SHALL BE RAIN TIGHT AND SHOULD BE APPROVED TO USE IN WET AND DRY LOCATIONS. -ALL CONDUITS AND EQUIPMENTS SHALL BE PAINTED TO MATCH THE EXISTING BACKGROUND. -THE PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH CBC SECTION 1609 TO WITHSTAND A MINIMUM OF 97 MPH WIND LOAD -DESIGN COMPLYING WITH LATEST EDITION OF CALIFORNIA ELECTRICAL CODE, NEC AND ALL LOCAL ORDINANCES. -SHOULD USE PROPER GROUND BAR AND KITS FOR GROUNDING -THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING. MECHANICAL OR BUILDING ROOF VENTS. -THE DISTANCE BETWEEN BOTTOM OF PANEL TO THE TOP OF ROOF SHOULD BE MIN 4". -BACKFEED BREAKER SHOULD BE AT THE OPPOSITE END OF BUS BAR. -INSTALLERS TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. -SEE THE SPECS SHEETS FOR ADDITIONAL INFORMATION. -THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS OF LOCAL UTILITY. -ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. -A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA . -WORKING DISTANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. -NO VENTS ( PLUMBING, MECHANICAL OR DORMER) TO BE COVERED OR REROUTED AROUND SOLAR MODULES.RELOCATION TO BE DONE ONLY AFTER APPROVAL. - ALL LABELS AND PLACARDS SHALL BE ATTACHED ACCORDING TO NEC AND THE LOCAL AHJ. -METAL CONDUIT AND ENCLOSURE SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING. -ALL OUTDOOR EQUIPMENT SHALL BE MIN NEMA 3R RATED. -PER CALIFORNIA RESIDENTIAL CODE (CRC) SECTIONS R314 AND R315 SMOKE ALARM AND CARBON MONOXIDE DETECTORS ARE RETROFITTED INTO THE EXISTING DWELLINGS. -ALL PHOTOVOLTAIC EQUIPMENT SHALL BE LISTED BY RECOGNIZED TESTING LAB. -ALL SOLAR ENERGY SYSTEMS SHALL MEET APPLICABLE HEALTH AND SAFETY STANDARDS REQUIREMENTS IMPOSED BY THE CITY AND STATE OF CALIFORNIA. -SOLAR ENERGY SYSTEMS FOR PRODUCING ELECTRICITY SHALL MEET ALL APPLICABLE SAFETY AND PERFORMANCE STANDARDS ESTABLISHED BY CALIFORNIA ELECTRIC CODE,THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, ACCREDITED TESTING LABORATORIES SUCH AS UNDERWRITER LABORATORIES AND WHERE APPLICABLE, RULES OF PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY. -THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS. -WHEN BACKFEED BREAKER IS USED AS POINT OF INTERCONNECTION, IT SHOULD NOT READ LINE AND LOAD. COVERSHEET STAMP PV1 40750 AVENIDA ROSARIO PALM DESERT, CA 92260 40750 AVENIDA ROSARIO PALM DESERT, CA 92260 146'-5" 73 ' - 5 " 78 ' - 1 1 " 147'-0" 32'± 12 ' ± 40'± 4' ± 1'-6" 1'-6" 3' - 0 " 3' - 0 " 3'-0" 1' - 6 " 1' - 6 " 3' - 0 " 9" JB MSPCB MODULE WATT: 400 W (32)PANASONIC EVPV400HK SYSTEM SIZE:12.80 KW DC (STC) :12.22 KW DC (PTC) :11.91 KW AC (CEC) (32)MICROINVERTERS: ENPHASE IQ8A-72-M-US AZIMUTH:180° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/29/2024 MICHELLE VARGAS RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:2/28/2023 SHEET NAME SHEET NUMBER 40750 AVENIDA ROSARIO PALM DESERT,CA,92260 PHONE:(760)898-3411 OCCUPANCY TYPE:V-B GROUP:R APN:622340018 SJ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 1 PLOT PLAN SCALE: 1/16"=1'-0"PV2 POINT LOAD CALCULATION PER ARRAY ITEM # OR LN FT WT (LBS)TOTAL WT (LBS) MODULES 32 45 1440 ROOF RAILS 213 0.5 106.5 MOUNTS 44 0.5 22.0 MICRO INVERTER/ POWER OPTIMIZER 32 2.4 76.8 TOTAL WEIGHT 1645.3 MODULE DIMENSIONS 71.70inx40.00 in 19.9 WEIGHT PER MOUNT 37.4 WEIGHT PER SQ FT(LBS/SQFT)2.6 WIND SPEED:97 MPH EXPOSURE C RISK CATEGORY II PLOT PLAN PV2 ROOF AZIMUTH 180° FROM NORTH LOCATIONS OF DC CONDUCTORS CONDUIT WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE OR HIP OR VALLEY AND FROM HIP OR VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE THE VENTILATION OPPORTUNITIES.CONDUIT RUNS BETWEEN SUB ARRAYS AND DC COMBINER BOX SHALL BE INSTALLED IN A MANNER THAT MINIMIZES THE TOTAL AMOUNT OF CONDUIT ON ROOF BY TAKING THE SHORTEST RUNS AND MINIMIZED IN THE PATHWAYS BETWEEN THE ARRAYS.DC WIRING SHALL BE INSTALLED IN A METALLIC CONDUIT OR RACEWAYS WHEN LOCATED WITHIN ENCLOSED SPACES IN A BUILDING. CONDUIT SHALL RUN ALONG THE BOTTOM OF THE LOAD BEARING MEMBERS ROOF COVERAGE ARRAY AREA 636.8 SQFT ROOF AREA 4089.0 SQFT %COVERAGE 15.6 %<33 ROOF 1:32 MODULES ROOF TILT@18° AZIMUTH@180° SWIMMING POOL BACK YARD NOTE: A 36 INCH WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING ROOF 1 (E)WALL AND GATE ROOF ACCESS POINTS CRC R24.7.0 DRIVE WAY (E)MAIN SERVICE PANEL AND (N)SOLAR BREAKER 36" FIRE PATHWAY PER CFC 605.11.1.2.1 ROOF ACCESS POINTS CRC R24.7.0 36" FIRE PATHWAY PER CFC 605.11.1.2.1 (E) WALL WIND LOAD CALCS MODULES AND RACKING WEIGHT(W)1645 LBS TOTAL MODULES AREA(A)636.8 SQFT WIND PRESSURE(PSF) P 35 PSF L=5/16" DIA LAG SCREWS 328 LBS/IN D=LAG SCREWS EMBEDEMENT 2.5 INCH QUANTITY OF LAG SCREWS(Q)88 QTY (N)COMBINER BOX BRANCH #1 BRANCH #2 BRANCH #3 AV E N I D A R O S A R I O HOVLEY LN W JB MSPCB 70'-8"3'-0" 11 ' - 4 " 11 ' - 6 " 23 ' - 1 " 13 ± 3 - 1 / 2 " RO O F S L O P E 72" O.C MAX 1/3*L MAX TYP END MOUNTING CLIP,TYP MID MOUNTING CLIP,TYP SOLAR STANDARD RAIL TYP 1/3*L MAX TYP 13 ± 3 - 1 / 2 " MODULE WATT: 400 W (32)PANASONIC EVPV400HK SYSTEM SIZE:12.80 KW DC (STC) :12.22 KW DC (PTC) :11.91 KW AC (CEC) (32)MICROINVERTERS: ENPHASE IQ8A-72-M-US AZIMUTH:180° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/29/2024 MICHELLE VARGAS RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:2/28/2023 SHEET NAME SHEET NUMBER 40750 AVENIDA ROSARIO PALM DESERT,CA,92260 PHONE:(760)898-3411 OCCUPANCY TYPE:V-B GROUP:R APN:622340018 SJ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 LEGEND JB INV SUB MSP ACD - JUNCTION BOX - INVERTER - AC DISCONNECT - MAIN SERVICE PANEL - SUB PANEL - ATTIC VENTS - DORMER VENTS -SKYLIGHT -CHIMNEY -PRODUCTION METERPM A/C -AIR CONDITON UNIT -SOLAR MODULES -FIRE ACCESS PATHWAY M -ELECTRIC METER CB -COMBINER BOX ROOF PLAN SCALE: 3/32"=1'-0"PV3 71 . 7 0 " 40.00" TYPICAL RACK MOUNT LAYOUT SCALE: 3/16"=1'-0"PV3 ROOF PLAN PV3-CONDUIT ON ROOF PANASONIC EVPV400HK 1 2 44 QTY ATTACHMENT POINTS @ 72" O.C. MAX ROOF 1 2X4 TRUSS@24" O.C TYPE NOTE: PV BREAKER IN MAIN PANEL ACTS AS A MEANS OF AC DISCONNECT 690.12(E)(1) ROOF AZIMUTH 180° FROM NORTH ROOF 1:32 MODULES ROOF TILT@18° AZIMUTH@180° (E)MAIN SERVICE PANEL AND (N)SOLAR BREAKER (N)COMBINER BOX AV E N I D A R O S A R I O HOVLEY LN W THWN-2 IN 3/4" EMT (3)AWG #6 L1 = BLACK L2 = RED N = WHITE (1)AWG #8 G = GREEN === -+-+-+ BRANCH CIRCUIT 1=11 MODULES === -+-+-+ EGC BRANCH CIRCUIT 3=10 MODULES PHOTOVOLTAIC ARRAY === -+-+-+ BRANCH CIRCUIT 2=11 MODULES JUNCTION BOX N G (3) 20A DPB (N)125A RATED IQ COMBINER 4 X2-IQ-AM1-240-4 W/IQ ENVOY SOLAR PV USE ONLY ENPHASE IQ8A MICRO INVERTER THWN-2 3/4" EMT AWG#10 L1=BLACK L2=RED N=WHITE AWG#8 G=GREEN 90° C WET & DRY ENPHASE Q CABLE IN FREE AIR L1=BLACK L2=RED G=GREEN #6AWG BARE CU BRANCH CIRCUIT #1,ISC=1.45A (N)175A DERATED MAIN DISCONNECT BW2175 (E)200A MAIN SERVICE PANEL CUTLER-HAMMER BI-DIRECTIONAL UTILITY METER 1 PHASE, 3 WIRE 120/ 240 V (N) PV BREAKER 60A DPB LOCATED AT OPPOSITE END OF MAIN BREAKER BR260 NEW, IF NO EXISTING GROUNDING ELECTRODE MODULE WATT: 400 W (32)PANASONIC EVPV400HK SYSTEM SIZE:12.80 KW DC (STC) :12.22 KW DC (PTC) :11.91 KW AC (CEC) (32)MICROINVERTERS: ENPHASE IQ8A-72-M-US AZIMUTH:180° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/29/2024 MICHELLE VARGAS RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:2/28/2023 SHEET NAME SHEET NUMBER 40750 AVENIDA ROSARIO PALM DESERT,CA,92260 PHONE:(760)898-3411 OCCUPANCY TYPE:V-B GROUP:R APN:622340018 SJ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 ELECTRICAL DIAGRAM PV4 ELECTRICAL NOTES: 1.) ALL EQUIPMENT TO BE LISTED BY UL OR RECOGNIZED TESTING LABORATORY. 2.) ALL PLACARDS AND SIGNAGE REQUIRED BY LATEST EDITION OF CEC AND NEC WILL BE INSTALLED AS REQUIRED. 3.) ALL THE CONDUIT RUNS SHALL HAVE SUFFICIENT WEATHER PROOF JUNCTION BOXES/COMBINER BOXES. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC AND CEC 5.) ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION AND ALL THE MOUNTING METALLIC EQUIPMENT SHALL BE GROUNDED ACCORDING TO MANUFACTURER INSTRUCTIONS. 6.) ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC ENGRAVED OR MACHINE PRINTED LETTER IN A CONTRASTING COLOR .THE PLAQUE SHALL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHODS AND SHALL BE UV RESISTANT IF EXPOSED TO DIRECT SUNLIGHT. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) AL THE PHOTOVOLTAIC SYSTEMS AND REQUIRED WIRINGS SHALL BE INSTALLED BY QUALIFIED PERSONNEL ONLY 9.) MICRO INVERTER SHALL CONTAIN GROUND FAULT DETECTION AND INTERRUPTION DEVICES. 10.) ALL WIRES ARE SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. 11.) IF THE EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, CONTRACTOR SHALL INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AS PER CALIFORNIA RESIDENTIAL CODE CRC SECTIONS R14 AND R15 PROVIDE SMOKE ALARMS ON THE FOLLOWING LOCATIONS: 1.SMOKE ALARM IN ALL SLEEPING ROOMS. 2.CO ALARMS IN ALL SLEEPING ROOMS WITHIN WHICH FUEL BURNING APPLIANCES ARE INSTALLED. 3.SMOKE ALARMS AND CO ALARM IN AREA PRECEDING SLEEPING ROOMS (SUCH AS HALLWAY),AND 4.SMOKE ALARM AND CO ALARM ON EACH STORY LEVEL OF THE DWELLING INCLUDING BASEMENTS AND HABITABLE ATTIC ROOMS 120% RULE ON BUS BAR MAIN SERVICE PANEL RATING 200A MAIN BREAKER RATING DERATED 175A 120% OF MAIN PANEL RATING 200*1.2=240A MAX SOLAR BACKFEED 240-175=65A SOLAR BACK FEED MICROINVERTERS 58A BACKFEED COMPLIES WITH NEC 705.12(D)(2) 58A <65A SYSTEM: MICROINVERTERS MAX OUTPUT POWER=349W AC 1.45x11=15.95A PER BRANCH CIRCUIT #1 1.45x11=15.95A PER BRANCH CIRCUIT #2 1.45x10=14.5A PER BRANCH CIRCUIT #3 MAX BRANCH AC REQUIRED CONDUCTOR AMPACITY (1.45X11X1.25)=19.94A AWG#10 DERATED AMPACITY 55X0.65X0.8=20.8A 20.8A>19.94A, THEREFORE AC WIRE SIZE IS VALID TOTAL OUTPUT CURRENT FROM COMBINER BOX 1.45X32=46.4A AC REQUIRED CONDUCTOR AMPACITY=46.4X1.25=58A AWG#6 DERATED AMPACITY 75X0.87x1.0=65.25A 65.25A>58A, THEREFORE AC WIRE SIZE IS VALID INVERTER #1 SPECIFICATIONS MANUFACTURER / MODEL #ENPHASE IQ8A-72-M-US NOMINAL AC POWER 349 KW NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 1.45 A SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #PANASONIC EVPV400HK VMP 42.1V IMP 9.51A VOC 48.8V ISC 10.25A TEMP. COEFF. VOC -0.24%/°K MODULE DIMENSION 71.70"L x 40.00"W x 1.18"D (In Inch) PTC RATING 381.9W NOTE: DERATE THE MAIN BREAKER FROM 200A TO 175A. LOAD CALCS ATTACHED BRANCH #1=11 MODULES BRANCH #2=11 MODULES BRANCH #3=10 MODULES NOTE: NOTE:QUAD 30A AND 20A DPB TO MAKE ROOM FOR SOLAR BREAKER.USE BQ220230 18" 4 " 1 8 ° 6'-0" MAX 6'-0" 6'-0" 6'-0" 6'-0" MODULE WATT: 400 W (32)PANASONIC EVPV400HK SYSTEM SIZE:12.80 KW DC (STC) :12.22 KW DC (PTC) :11.91 KW AC (CEC) (32)MICROINVERTERS: ENPHASE IQ8A-72-M-US AZIMUTH:180° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/29/2024 MICHELLE VARGAS RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:2/28/2023 SHEET NAME SHEET NUMBER 40750 AVENIDA ROSARIO PALM DESERT,CA,92260 PHONE:(760)898-3411 OCCUPANCY TYPE:V-B GROUP:R APN:622340018 SJ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 ATTACHMENT DETAILS PV5 1 ATTACHMENT TYPE: PEGASUS S TILE REPLACEMENT MOUNT - (CONCRETE S TILE ROOF) SCALE: NTSPV5 2X4 TRUSSES @24"O.C (E)1/2" CDX PLYWOOD (2) 5/16"x3-1/2" SS LAG BOLT@ 6' O.C Max. OVER EXISTING SHEATHING AND ROOF TRUSSES AS SHOWN. MIN 2-1/2" PENETRATION IRON RIDGE XR10 RAIL (E)CONCRETE S TILE ROOF MAX 1 LAYER MASTIC, MESH AND MASTIC FLASHING PEGASUS S TILE REPLACEMENT MOUNT 2X4 TRUSS@ 24" O.C SOLAR PANEL PORTRAIT JB MSPCB MODULE WATT: 400 W (32)PANASONIC EVPV400HK SYSTEM SIZE:12.80 KW DC (STC) :12.22 KW DC (PTC) :11.91 KW AC (CEC) (32)MICROINVERTERS: ENPHASE IQ8A-72-M-US AZIMUTH:180° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/29/2024 MICHELLE VARGAS RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:2/28/2023 SHEET NAME SHEET NUMBER 40750 AVENIDA ROSARIO PALM DESERT,CA,92260 PHONE:(760)898-3411 OCCUPANCY TYPE:V-B GROUP:R APN:622340018 SJ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 ! WARNING ! ELECTRIC SHOCK HAZARD THE TERMINALS ON LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION (690.13(B) CEC AT ALL "J" BOXES, COMBINER BOX,ENCLOSURES/EMT ENCLOSURES/DISCONNECTS ! WARNING ! POWER SOURCE OUTPUT CONNECTIONS, DONOT RELOCATE THIS OVER CURRENT DEVICE NEC 705.12 (B)(2)(3)(b)PLACED ON MAIN PANEL/BREAKER LOCATION PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE PLACED ON SOLAR BREAKER ! WARNING ! ! WARNING ! DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC CEC 705.12 D(3),NEC 690.59 ON MAIN PANEL ! WARNING ! PHOTOVOLTAIC POWER SOURCE ON ALL CONDUITS SPACED AT MAX 10 FT PLACARDS PV6A POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCE WITH DISCONNECT LOCATED AS SHOWN CAUTION PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 46.4 A NOMINAL OPERATING AC VOLTAGE 240 V CEC 690.54 PLACED ON MAIN PANEL SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS WITHIN 3 FT OF MAIN PANEL/AC DISCONNECT PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR ADHESIVE.WARNING LABELS WHITE LETTERS ON RED BACKGROUND AND NON-BOLD ARIAL OR SIMILAR FONT.MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT CEC 690.56 C(3) PLACED WITHIN 3 FT OF RAPID SHUT DOWN SWITCH DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ! WARNING ! PHOTOVOLTAIC POWER SOURCE CEC 690.31 (G)3-4 ON ALL EMT CONDUIT, ENCLOSURE,COMBINER BOXES,DISCONNECTS ! ! WARNING ! TURN OFF PHOTOVOLTAIC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27 C, COMBINER BOX, ENCLOSURE/CONDUIT ENCLOSURE/DISCONNECT RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM MAIN SERVICE PANEL AND SOLAR BREAKER COMBINER BOX WARNING MAIN BREAKER SIZE IS REDUCED TO 175A FOR PHOTOVOLTAIC CIRCUIT. DO NOT INCREASE MAIN BREAKER SIZE. AT SERVICE EQUIPMENT LOCATION IF DERATING THE MAIN BREAKER ! WARNING ! TURN OFF UTILITY DG AC DISCONNECT PRIOR TO WORKING INSIDE PANEL PLACED ON MAIN PANEL ! CAUTION ! SOLAR SYSTEM CONNECTED AND ENERGIZED PLACED ON MAIN PANEL/AC COMBINER IF ANY AV E N I D A R O S A R I O PHOTOVOLTAIC ARRAY JB MSPCB MODULE WATT: 400 W (32)PANASONIC EVPV400HK SYSTEM SIZE:12.80 KW DC (STC) :12.22 KW DC (PTC) :11.91 KW AC (CEC) (32)MICROINVERTERS: ENPHASE IQ8A-72-M-US AZIMUTH:180° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/29/2024 MICHELLE VARGAS RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:2/28/2023 SHEET NAME SHEET NUMBER 40750 AVENIDA ROSARIO PALM DESERT,CA,92260 PHONE:(760)898-3411 OCCUPANCY TYPE:V-B GROUP:R APN:622340018 SJ SUNLOGIX ENERGY 77585 ENFIELD LN SUITE A PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 OPTIMIZER CHART PV6B OPTIMIZERS/MICRO-INVERTERS CHART 410W/400W Panasonic Life Solutions Company of America Two Riverfront Plaza, Newark, NJ 07102 panasonicHIT@us.panasonic.com na.panasonic.com/us/solar All Rights Reserved © 2023 COPYRIGHT Panasonic Corporation Specifications are subject to change without notice RS22124DS-R5 EVERVOLT™ SOLAR MODULE BLACK SERIES Heterojunction Cell Technology with Gapless Connections Half-cut cells with heterojunction technology with gapcell connections minimizes electron loss, maximizes conversion efficiency, and produces considerably higher power output over conventional panels. Durability & Quality Assurance N-type cells result in minimal Low Induced degradation (LID) and Potential Induced degradation (PID), which supports reliability and longevity. As a solar pioneer for over 40 years, Panasonic EverVolt solar panels are backed by innovation, experience and a brand you can trust. AllGuard and TripleGuard 25-Year Warranty1 A long-term warranty is only as reliable as the company behind it. AllGuard and TripleGuard 25-year warranties cover EverVolt panels for performance, product, parts and labor for 25 years. Whether in year three or year 25, your Panasonic warranty will be there when you need it. The Panasonic Advantage High Efficiency in High Temperatures Produce more energy throughout the day even on the hottest days in the warmest climates. EverVolt solar panels outperform others when temperatures rise due to our industry-leading 0.26%/°C temperature coefficient. Higher Module Efficiency Superior module efficiency of 22.2% and 21.6%, respectively, allows maximum power production with less roof space. Offering clean aesthetics and one of the industry’s lowest annual degradation rates, power output of at least 92% is guaranteed after 25 years. Improved Performance When Shaded Continuous power production in shaded areas for greater energy yields and output. More sunlight absorption means more clean power to your home. Panasonic Life Solutions Company of America Two Riverfront Plaza, Newark, NJ 07102 panasonicHIT@us.panasonic.com na.panasonic.com/us/solar DIMENSIONS All Rights Reserved © 2023 COPYRIGHT Panasonic Corporation Specifications are subject to change without notice RS22124DS-R5 DEPENDENCE ON IRRADIANCE CAUTION! Please read the installation manual carefully before using the products. Used electrical and electronic products must not be mixed with general household waste. For proper treatment, recovery and recycling of old products, please take them to applicable collection points in accordance with your national legislation. NOTE: Specifications and information above may change without notice. 410W/400W EVERVOLT™ SOLAR MODULE BLACK SERIES NOTE: Values at standard test conditions(STC: air mass AM1.5 irradiance 1000W/m2, temperature 25ºC). * Maximum power at delivery. For guarantee conditions, please check our guarantee document. ** Installation need to be registered through our website www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year Product workmanship. Otherwise, Product Workmanship will be only fifteen (15) years. ¹Equipment must be installed by a Panasonic Authorized, Premium, or Elite installer and registered at www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year AllGuard and TripleGuard warranty. ² Refer to installation manual for detailed mechanical loading information *** 1st year 98%, after 2nd year 0.25% annual degradation to year 25. 92% 80% More power over 25 years 70% 80% 90% 98% 100% PERFORMANCE WARRANTY Model EVPV410HK EVPV400HK Rated Power (Pmax)¹410W 400W Maximum Power Voltage (Vpm) 42.7V 42.1V Maximum Power Current (lpm)9.61A 9.51A Open Circuit Voltage (Voc) 49.0V 48.8V Short Circuit Current (lsc) 10.35A 10.28A Temperature Coefficient (Pmax) -0.26 %/°C Temperature Coefficient (Voc) -0.24 %/°C Temperature Coefficient (lsc) 0.04 %/°C NOCT 44°C (±2°C) CEC PTC Rating 390.4W 381.0W Module Efficiency 22.2%21.6% Power Density 20.6 W/ft²20.1 W/ft² Maximum System Voltage 1000V Maximum Series Fuse 25 A Watt Class Sorting -0/+10W MECHANICAL SPECIFICATIONS Junction Box 3-part, 3 bypass diodes, IP68 rated in accordance with IEC 62790 Connector Type Stäubli MC4 PV-KBT4/KST4 (4 mm²) in accordance with IEC 62852 only when connected Cable Size / Type 12AWG(4mm2) PV Wire, 43in + 47in in accordance with EN 50618 Max Snow Load (+)²146 psf (7000 Pa)+ Max Wind Load (-)²83.5 psf (4000 Pa)+ Dimensions LxWxH 71.7 x 40.0 x 1.2 in (1821 x 1016 x 30 mm) Weight 45.0 lbs (20.5kg) Pallet Dimensions LxWxH 74 x 41.5 x 47.5 in Quantity per Pallet / Pallet Weight 33 pcs/ 1620 lbs.(735kg) Quantity per 40’ Container 792 pcs ELECTRICAL SPECIFICATIONS OPERATING CONDITIONS AND SAFETY RATINGS +Test Load. Design Load should be multiplied by two thirds. Reference data for model : EVPV410HK Cell temperature : 77ºF (25ºC) Certifications IEC61215-2:2016 [Hailstone 35mm] Fire Type 2 (UL 61730) Salt Mist [IEC 61701] PID [IEC 62804] Ammonia Resistance [IEC 62716] Lead-free acc. to RoHS EU 863/2015 [IEC 62321] Operating Temperature -40ºF to 185ºF (-40ºC to 85ºC) Limited Warranty 25* Yrs Workmanship and Power Output (Linear)*** Power Output in Year 1 98% Annual Degradation 0.25% Power Output in Year 25 92% 0 0 10 20 30 40 50 2 4 6 8 10 12 Cu r r e n t [ A ] Voltage [V] 1000W/m 800W/m 600W/m GR GR GR GR GR [6.0±0.2] 1.1 [28] 4 0 ± 0 . 1 [ 1 0 1 6 ± 2 . 5 ] 6.05 [153.7] 1.18 [30] Measurements in in [mm] 0.9 [22.5]1.8 [45] 0. 7 [1 7] 6.05 [153.7] 0.24±0.01 47.2 [1200] 0.81±0.02 [20.5±0.5] 0.43±0.008 [11±0.2] 0. 2 6 ± 0 . 0 0 8 [ 6 . 6 ± 0 . 2 ] 35.5 [901] 71.7±0.1 [1821±2.5] 18.1 [460] 43.3 [1100] 38 . 4 ± 0 . 1 [ 9 7 5 ± 2 . 5 ] 26.4±0.12 [671±3] DATA SHEET IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Easy to install • Lightweight and compact with plug-n- play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) Note: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. *Only when installed with IQ System Controller 2, meets UL 1741. **IQ8M and IQ8A support split-phase, 240V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Connect PV modules quickly and easily to the IQ8 Series Microinverters that has integrated MC4 connectors. IQ8MA-MC4-12A-DS-0080-02-EN-US-2022-12-12 (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8M and IQ8A Microinverters INPUT DATA (DC)IQ8M-72-M-US IQ8A-72-M-US Commonly used module pairings1 W 260 – 460 295 – 500 Module compatibility 54-cell / 108 half-cell, 60-cell / 120 half-cell, 66-cell / 132 half-cell and 72-cell / 144 half-cell MPPT voltage range V 30 – 45 32 – 45 Operating range V 16 – 58 Min. / Max. start voltage V 22 / 58 Max. input DC voltage V 60 Max. continuous input DC current A 12 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8M-72-M-US IQ8A-72-M-US Peak output power VA 330 366 Max. continuous output power VA 325 349 Nominal (L-L) voltage / range2 V 240 / 211 – 264 Max. continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 47 – 68 AC short circuit fault current over 3 cycles Arms 2 Max. units per 20 A (L-L) branch circuit3 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.8 97.7 CEC weighted efficiency %97.5 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC Connector type Stäubli MC4 Dimensions (H x W x D)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.1 kg (2.43 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1- 2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8MA-MC4-12A-DS-0080-02-EN-US-2022-12-12 Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, to secure systems flush against residential roofs. Corrosion-Resistant Materials XR Rails are compatible with FlashFoot and other pitched roof attachments. IronRidge offers a range of tilt leg options for flat roof mounting applications. All XR Rails are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. © 2019 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.14 Tech Brief Rail Selection The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. Load Rail Span Snow (PSF) Wind (MPH) 4’5’ 5”6’8’10’12’ None 100 120 140 XR10 XR100 XR1000 160 10-20 100 120 140 160 30 100 160 40 100 160 50-70 160 80-90 160 XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. •8’ spanning capability •Heavy load capability •Clear & black anodized finish •Internal splices available XR10 XR10 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. •6’ spanning capability •Moderate load capability •Clear & black anodized finish •Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It’s built to handle extreme climates and spans up to 12 feet for commercial applications. •12’ spanning capability •Extreme load capability •Clear anodized finish •Internal splices available EASIER TILE INSTALLATIONS Pegasus Solar’s Tile Replace Mount eliminates grinding of tiles and gives you extra tiles to replace broken tiles. Reduce fatigue and increase crew productivity by making installations easier and faster. A BETTER DAY ON THE JOB TILE REPLACE MOUNT 25-year Warranty Manufactured with advanced materials and coatings to outlast the roof itself Universal Fits most tile thickness and batten or batten-less roofs. S-flashing works on concrete and clay tiles. Compatible with all rails. Code Compliant Fully IBC/CBC Code Compliant Exceeds ASCE 7-16 Standards Tested to AC286 Kit Packaging Flashing kit includes flashing, post, mounting bolt and EPDM boot. Sled kit includes universal sled, SS lags and base flashing (optional). No grinding or cutting tiles Flashing slides into place then post twist-locks into position Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804 510.210.3797 www.pegasussolar.com Gain one roof tile per mount. Eliminate trips to the tile yard to purchase replacement tiles SKU PSTR-FWB0 PSTR-SB00 Tile Type Flat-Tile S-Tile & Clay Tile W-Tile Any Hardware Included Flashing, Post, Mounting Bolt, EPDM Boot Install Application Rails Certifications IBC, ASCE/SEI 7-16, AC286 Material Painted Galvalume Plus Flashing, Aluminum Post Aluminum Sled, Aluminum Base Flashing Kit Quantity 12 12 Boxes Per Pallet 36 36 TILE REPLACE MOUNT Patents Pending. All rights reserved. © 2020 Pegasus Solar Inc. 1.Remove tile to be replaced and locate rafter. 3.Slide replacement flashing under left and up-roof tiles, ensuring post hole lines up with sled channel. 2.Install sled over optional base flashing and drive lag screws to required embed- ment. Waterproof per all applicable codes and standards as required by the AHJ. 4.Insert post with T-bolt into sled channel. Once engaged, rotate post clockwise to tighten T-bolt. Install EPDM boot over post and snug to flashing. Specifications Sled Kit (Universal) Flat Tile Replace Kit S Tile Replace Kit W Tile Replace Kit Sled Kit Sled, 5/16” SS Lags, Base Flashing 15" 17" 2.2" 13" 18"4" 14" 18"3.5" Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804 510.210.3797 www.pegasussolar.com 1.5" 4.1" 1.5" 5.7" 1.5" 4.7" 0.6" 4.1" 8.5" 6.8" 12.7" 1.6" Tile Replace Flashing Kit (Flat, S & W) PSTR-FSB0 PSTR-FFB0