HomeMy WebLinkAboutPSPA21-0030 REVISED PLAN AP.pdf
CITY OF PALM DESERT
Building & Safety Department
73-510 Fred Waring, Palm Desert, CA (760) 776-6420
PLAN RE-CHECK / PLAN REVISION SUBMITTAL
Date: Permit No:
Project Address: Suite#
Contact Person:
Name Company Name Tel#
Comments:
Plan Recheck (Projects in plan check - permit not yet issued.) All plan check corrections require a narrative.
Plan Revision (Projects that have been stamped approved or permits that have been issued and are currently under
construction.) Plans submitted for revisions shall be accompanied by a narrative of the proposed changes, shall be
bubbled and dated. A plan review fee of $168.00 per hour (with one-half hour minimum) may be collected from the
applicant at the time of approval.
(For Office Use Only) Plan Location:
Checked in by:
Spa Specs
Pool Specs
Tile Specs
Approval
Set Back
Set Back
Set Back
Side property line and
6'High Block wall
Side property line and 6'High block wall
Back property line and 6'High block wall
(2) 31" Planter Bowls
New 5' High Iron
Fence by owner
self
6' 6"
23
'
2
"
5'5'
11'
14'
12
'
21'
13' 6"
22' 6"
6' 6"
6'
RBB +20" High
(2) 6" High(2) 12" High
Center steps
3'6" WD5' WD
3'6" WD
3'3'
LED Pool LightLED Pool LightLED Pool Light
Electrical Main
Panel. Add 50 Amp
breaker with 25 lf
#8 wire in pvc
conduit to
equipment
Gas Meter
10
'
2'
GA
S
GA
S
7'
7'
(2) 12" WD
Scale: 3/32" = 1 ft
RTNS:
Dig Type
Jets:
Notes:
Spillover Length(s):
Coping Material:Travertine
Interior Finish: mini Pebble
Spillover Length(s):
Interior Finish: Mini Pebble
Coping Material: Tile
Spa Tile Material: Tile TBD
Pool Tile Material:Tile TBD
Surface Material:
Coping Material:
NOTES:
Turn Down:Riser:
Block:
Lot #:
PB:PG:
Subdivision:
Gate Code:
Notes:
X
Notes:
Raised Beams:See Plans
Notes:
Skim:
Perimeter:74 Lf Area:252 Sq ft
Envelope:21'x12'
Depth:3'6" to 5'
Drains:Lights:2 Glo Brites
Area:49 Sq FtPerimeter:28 Lf
Height:infinity +18"
Circ Pump:1
Lights: 1 globrite
Control Panel:East Touch 4
Drains:
Project Name: Lucht Residence
Client Name: Lisa and Duane
Email:
Client Phone: 204-999-4715
Address: 77669 Ashberry Ct
City: Palm Desert
State/Province: CA
Zip/Postal Code: 92211
Designer Name: Gary Houck
Pump #2:NA
Coping Area:
Pump #3:NA
Area:
Filter:420 cartridge
Perimeter:
Heater:400,000 BTU
Cleaner:NA
Pool Light:2 Glo brites
P.C.:
Spa Light:1 Globrite
Volume:
Other:(2) 24" Sheer
Sescents
I/we (the undersigned) have reviewed this plan
and approve it as correct within reasonable
tolerance. I/we understand that any changes
made to a shape or to a location may delay the
project and/or result in additional cost.
Other:
RTNS:
Other:
Other:
Other:
Deck Specs
Fill Line:
Blower:NA
Sanitizer:Salt System
Remote:Indoor remote wall M.
NOTES:
EquipmentHigh Density
Polyethylene Natural
Gas lines 1 1/2" Meter
to equipment 25 lf.
Government code section 4216.2 (a) (1) except in
emergency, any person planning to conduct excavation
shall contact appropriate regional notfication center,at
least two working days, but no more then 14 calendar
days, prior to commencing the excavation, if the
excavation will be conducted in the areas that is known,
or reasonably should known, to contain subsurface
installations other that the the underground facialities
owned or operated by the excavator and if practical, the
excavator shall delinate with white or other suitable
markings the area to be excavated.
All construction shall comply with the CA
residential codes (based on 2018IRC)
2019mechanical code (based on 2018 UM)
2019 Plumbing code (based on 2018UPC
2019 Electrical code (based on 2017 NE)
2019Energy code based on CA energy efficiency
standards.
2019 Green code CA building standards
commission.
Iden tifing and
demonstrating
equipotential
bonding
(CEC 680.26.
X_________________________
Submitted by Owner/ Builder
Jorge Silva
X_________________________
Submitted by Owner/ Builder
Jorge Silva
Pool Equipment with sub
panel Seimically
Anchored to a concrete
pad. with a minimum
clearence of 36" from
disconnect
The pool suctions are 2,1/2" PVC for skimmer, spa
suctions and pool returns. The Spa jets and returns
are 2,1/2" PVS. No overhead electrical wires or
utilities/service. Pool safety barriers will be pool
alarms on all doors. Water/Splash alarms of each
type shall meet ASTM standard F220.8 A self-closing,
self latching device with a release mechanism placed
no lower than 54 inches above the floor on the
private single-family home's doors providing direct
access to the swimming pool or spa. Outdoor blue
bubble cover to accomidate energy efficency
standards.
The equipotential bonding grid shall be extending
under paved or unpaved areas.
This property has no over head
power lines and complies with
electrical table -code 680.0 for
over head conductor clearences
Anti entrapment covers meet current standards of
the American Society for Testing and Materials
(ASTM) or American Society of Mechanical
Engineers. Identifying the minimum 3' separation
between all drains and be hydraulically balanced
with a min. 3' separation and noting hydraulically
balanced in the pool and spa.