HomeMy WebLinkAboutPSPA21-0030 Corrections.pdfSpa Specs
Pool Specs
Tile Specs
Approval
Set Back
Set Back
Set Back
Side property line and
6'High Block wall
Side property line and 6'High Block wall
Back property line and 6'High Block wall
(2) 31" Planter Bowls
New 5' High Iron
Fence by owner
self
6' 6"
23
'
2
"
5'5'
11'
14'
12
'
21'
13' 6"
22' 6"
6' 6"
6'
RBB +20" High
(2) 6" High(2) 12" High
Center steps
3'6" WD5' WD
3'6" WD
3'3'
LED Pool LightLED Pool LightLED Pool Light
Electrical Main
Panel. Add 50 Amp
breaker with 25 lf
#8 wire in pvc
conduit to
equipment
Gas Meter
GA
S
GA
S
7'
7'
(2) 12" WD
Scale: 3/32" = 1 ft
RTNS:
Dig Type
Jets:
Notes:
Spillover Length(s):
Coping Material:Travertine
Interior Finish: mini Pebble
Spillover Length(s):
Interior Finish: Mini Pebble
Coping Material: Tile
Spa Tile Material: Tile TBD
Pool Tile Material:Tile TBD
Surface Material:
Coping Material:
NOTES:
Turn Down:Riser:
Block:
Lot #:
PB:PG:
Subdivision:
Gate Code:
Notes:
X
Notes:
Raised Beams:See Plans
Notes:
Skim:
Perimeter:74 Lf Area:252 Sq ft
Envelope:21'x12'
Depth:3'6" to 5'
Drains:Lights:2 Glo Brites
Area:49 Sq FtPerimeter:28 Lf
Height:infinity +18"
Circ Pump:1
Lights: 1 globrite
Control Panel:East Touch 4
Drains:
Project Name:Luch Residence
Client Name:Lisa and Duane
Client Email:
Client Phone:204-999-4715
Address:77669 Ashberry Ct
City:Palm Desert
State/Province:CA
Zip/Postal Code:
Designer Name:Gary Houck
Pump #2:NA
Coping Area:
Pump #3:NA
Area:
Filter:420 cartridge
Perimeter:
Heater:400,000 BTU
Cleaner:NA
Pool Light:2 Glo brites
P.C.:
Spa Light:1 Globrite
Volume:
Other:(2) 24" Sheer
Sescents
I/we (the undersigned) have reviewed this plan
and approve it as correct within reasonable
tolerance. I/we understand that any changes
made to a shape or to a location may delay the
project and/or result in additional cost.
Other:
RTNS:
Other:
Other:
Other:
Deck Specs
Fill Line:
Blower:NA
Sanitizer:Salt System
Anti entrapment covers meeting currentstandardsof the
American Society for Testing and Materials (ASTM) or American Society
of Mechanical Engineers. Identifying the minimum 3' separtion between
all drains and be be hydraulically balanced. with a min. 3' separtion and
noting hyraulicaly balanced in the
Pool and spa
Remote:Indoor remote wall M.
NOTES:
EquipmentHigh Density
Polyethylene Natural
Gas lines 2" Meter to
equipment 25 Lf
Government code section 4216.2 (a) (1) except in
emergency, any person planning to conduct excavation
shall contact appropriate regional notfication center,at
least two working days, but no more then 14 calendar
days, prior to commencing the excavation, if the
excavation will be conducted in the areas that is known,
or reasonably should known, to contain subsurface
installations other that the the underground facialities
owned or operated by the excavator and if practical, the
excavator shall delinate with white or other suitable
markings the area to be excavated.
All construction shall comply with the CA
residential codes (based on 2018IRC)
2019mechanical code (based on 2018 UM)
2019 Plumbing code (based on 2018UPC
2019 Electrical code (based on 2017 NE)
2019Energy code based on CA energy efficiency
standards.
2019 Green code CA building standards
commission.
Idenfifing and
demonstrating
equipotential
bonding
(CEC 680.26.
X_________________________
Submitted by Owner/ Builder
Jorge Silva
X_________________________
Submitted by Owner/ Builder
Jorge Silva
Pool Equipment Seimically
Anchored to a concrete pad.
with a minimum clearence
of 36" from disconnect
The pool suctions are 2,1/2" PVC for skimmer, spa
suctions and pool returns. The Spa jets and returns
are 2,1/2" PVS. No overhead electrical wires or
utilities/service. Pool safety barriers will be pool
alarms on all doors. Water/Splash alarms of each
type shall meet ASTM standard F220.8 A self-closing,
self latching device with a release mechanism placed
no lower than 54 inches above the floor on the
private single-family home's doors providing direct
access to the swimming pool or spa. Outdoor blue
bubble cover to accomidate energy efficency
standards.
The equipotential bonding grid shall be extending
under paved or unpaved areas.