HomeMy WebLinkAboutAPPROVED SOLR20-0280 REVIEW 2.pdfH o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Ca i r n s R e s i d e n c e 20196 33 1 A r r o w h e a d D r Pa l m D e s e r t , C A 9 2 2 1 1 06/03/2020 SF MJR Sheet Michael Rango PV-0.0 CO V E R S H E E T DESCRIPTION OF WORK: ROOF MOUNTED PHOTOVOLTAIC (SOLAR ELECTRIC) INSTALLATION FLUSH MOUNTED @ 21° FACING AN AZIMUTH OF 168° CONSISTING OF (27) PANASONIC 325 WATT MODULES (8.775Kw) INCLUDING NEW TESLA BATTERY BACKUP SYSTEM. RACK MOUNTING SYSTEM IS UNIRAC SOLARMOUNT ALUMINUM SUPPORT RAILS AND SUNMODO FLASHED COMPOSITION SHINGLE MOUNTS. INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES: CEC 2019 - ARTICLE 690, 705,706 AND OTHERS NEC 2020 705.13 CPC 2019 CBC 2019 CMC 2019 CFC 2019 DRAWING SHEETS: COVER SHEET PV-0.0 SITE PLAN PV-1.0 ROOF PLAN PV-2.0 SINGLE LINE DIAGRAM PV-3.0 MOUNTING DETAIL PV-4.0 WARNING LABELING PV-5.0 SPECIFICATION SHEETS: MODULE AND INVERTERS TESLA POWERWALL2 TESLA GATEWAY UNIRAC CERTIFICATION NTS GENERAL NOTES: 1.ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDER THE DIRECT SUPERVISION OF A LICENSED ELECTRICIAN. 2.ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741SA CERTIFIED AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVED FOR IT'S PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. 3.THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAIC SYSTEM WHEN THE UTILITY GRID IS NOT IN OPERATION. 4.PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCAL AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. 5.THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ON THE ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE PHOTOVOLTAIC SYSTEM OR INSTALLATION. 6.ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS. 7.ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS. 8.TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTURE Palm Desert Municipal Code Requirements: (required on first page) Basic Wind Speed: (3 second gust) •Risk Category IV - 108 mph (Palm Desert use Category IV) CONSTRUCTION HOURS: OCTOBER 1 THRU APRIL 30 MAY 1 THRU SEPTEMBER 30 Monday - Friday 7:00 a.m. - 5:30 p.m. Monday - Friday 5:30 a.m. - 7:00 p.m. Saturday 8:00 a.m. - 5:00 p.m. Saturday 8:00 a.m. - 5:00 p.m. Sunday NOT ALLOWED Sunday NOT ALLOWED Government Code Holidays-- NOT ALLOWED A violation of the above work hours is a citable offense under Palm Desert Municipal Code Section 9.24.070. A R R O W H E A D D R H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Ca i r n s R e s i d e n c e 20196 33 1 A r r o w h e a d D r Pa l m D e s e r t , C A 9 2 2 1 1 06/03/2020 SF MJR Sheet Michael Rango PV-1.0 SI T E P L A N 1" = 15' For Photovoltaic arrays occupying not more than 33 percent of the plan view total roof area, not less than 18" clear set back is required on both sides of a horizontal ridge. For Photovoltaic arrays occupying more than 33 percent of the plan view total roof area, not less than 36" clear set back is required on both sides of a horizontal ridge. CRC R324.6.2 Not less than two minimum 36" wide pathways on separate roof planes, from lowest roof edge to ridge, shall be provided on all buildings. At least one pathway shall be provided on the street or driveway side of the roof. CRC R324.6.1 Designation of ridge, hip, and valley does not apply to roofs with 2-in-12 or less pitch. Total sq ft = 4,069 Solar sq ft = 397 = 9.7% SITE PLAN KEYNOTE: EXISTING ELECTRICAL 1.1 200A MAIN ELECTRICAL PANEL NEW ELECTRICAL (ADJACENT TO MSP) 2.1 100A SYSTEM AC DISCONNECT 2.2 30A ESS SAFETY DISCONNECT [2 of 2] NEW ELECTRICAL (INSIDE GARAGE) 2.3 TESLA GATEWAY 2.4 BU/CRITICAL LOADS PANEL 2.5 GENERATION PANEL 2.6 ESS SAFETY DISCONNECT [1 of 2] 2.7 TESLA POWERWALL 2.8 SE7600H-US PV INVERTER SITE LEGEND FIRE EASEMENT/ACCESS EAVE SETBACK/WALL 4' SPAN BETWEEN MOUNTS IS TYPICAL MAX SPAN 6' H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Ca i r n s R e s i d e n c e 20196 33 1 A r r o w h e a d D r Pa l m D e s e r t , C A 9 2 2 1 1 06/03/2020 SF MJR Sheet Michael Rango PV-2.0 RO O F P L A N 1" = 6' 1.VERIFY RAFTER SPACING IN THE FIELD BEFORE ATTACHING MOUNTS ROOF. 2.ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF RAFTERS AND MAKE STRUCTURAL CONNECTION TO THE RAFTERS. 3.STRUCTURAL CONNECTION TO ENGINEERED TRUSS SHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAG SCREWS 3" MIN. EMBEDMENT. 4.ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS. 5.PHOTOVOLTAIC MODULES SHALL HAVE 1.7 MOUNTS (LAG SCREWS) PER PANEL. 6.(E) ROOF STRUCTURE IS 21 DEGREE 2X4 ENGINEERED TRUSS 24" O.C TYP. 7.(E) ROOFING MATERIAL UNDER ARRAY IS 1 LAYER OF ASPHALT COMPOSITION SHINGLES OVER 1 LAYER OF 30LB. FELT PAPER AND 1/2" OSB PLYWOOD DECKING (SPANISH TILE INLAY). 8.MODULE DIMENSIONS 62.6" x 41.5" WEIGHT LOAD ANALYSIS MODULE WEIGHT 40.8 LBS NO.OF MODULES 27 TOTAL WEIGHT OF MODULES 1102 LBS TOTAL WEIGHT OF RACK SETS 259 LBS TOTAL WEIGHT OF SOLAR ARRAY 1,361 LBS HEIGHT OF EACH MODULE 5.2 FEET WIDTH OF EACH MODULE 3.5 FEET AREA OF ONE MODULE 18.02 SQ FT AREA OF ENTIRE SOLAR ARRAY 487.1 SQ FT TOTAL DISTRIBUTED WEIGHT 2.8 LBS/SQ FT NO.OF SOLAR STANCHIONS 46 WEIGHT LOAD PER STANCHION 27.0 LBS MOUNT PLAN KEYNOTE: RACK MOUNT COMPONENTS 1.1 UNIRAC ALUMINUM SUPPORT RAIL 1.2 SUNMODO FLASHED COMPOSITION SHINGLE MOUNTS STRUCTURAL 2.1 ROOF SUPPORTS 2x4 ENGINEERED TRUSS (24" O.C.) NOTES:EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690, 705 , 706 AND OTHERS. 1. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS A PHOTOVOLTAIC DISCONNECT. 2. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING-ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS-TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION" 3. PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2. INVERTER OUTPUT VOLTAGE 4. LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS PER NEC 690-64(b)7. 5. INDIVIDUAL INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE. 6.ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE. 7.ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBLE TO ANYONE OTHER THAN QUALIFIED PERSONS. 8.ALL PV SYSTEM EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY. 9.ALL EXTERIOR WIRING MATERIAL SHALL BE SUITABLE FOR A SUN EXPOSURE AND WET LOCATIONS. 10.REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR OUTPUT CIRCUIT CONDUCTOR. 11.CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED. 12.ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2019 CALIFORNIA ELECTRIC CODE & NEC 2020 705.13. 13.BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT. 8,775 WATT DC (8,083 WATT AC) SOLAR ELECTRIC ARRAY 27 PANASONIC HIT 325 WATT MODULES MODEL NO. VBHN325KA03 27 x 302.4 PTC x 99% EFF = 6.586 kW AC INDIVIDUAL MODULE RATING: PTC = 302.4 WATTS Voc = 70.9 VDC Isc = 5.94 AMPS AC OUT PV DC IN 70A BREAKER (N) GENERATION PANEL 125A BUSS, 120/240V, 1PH, 3W TESLA GATEWAY 30A ESS METER (E) MAIN SERVICE PANEL 200A BUSS, 120/240V, 1PH, 3W EXISTING AC GEC 150A BREAKER MSP 70A 70A 100A/240V F G G J-BOX BA SOLAREDGE POWER OPTIMIZER P400 RATED DC INPUT POWER - 400 WATTS MAXIMUM INPUT VOLTAGE - 80 VDC MPPT RANGE - 8 TO 80 VDC MAXIMUM INPUT CURRENT - 12.5 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5250 WATTS STC PER STRING MAXIMUM 1 STRING OF 14 40A AC OUT 30A (N) ESS DISCONNECT (2 OF 2) NEXT TO MSP (N) ESS DISCONNECT (1OF 2) LINE OF SITE D 30A/240V 30A/240V TESLA POWERWALL 2 USABLE ENERGY 13.5kwh MAX OUTPUT 5kW POWER FACTOR +/- 0.85 240V/24A SE7600H-US = 32A x 1.25 = 40A TESLA BAT. 24A x 1 = 24A x 1.25 = 30A TOTAL 56A x 1.25 = 70A INTEGRATED GFCI AND 240 VAC, 32 AMPS MAX OUTPUT: 7600 WATTS MAX INPUT: 400 TO 480 VDC GRID-TIE INVERTER SOLAREDGE SE7600H-US OUTPUT EFFICIENCY: 99% DC DISCONNECTS (N) SYSTEM DISCONNECT NEXT TO MSP SE7600H-US = 32A x 1.25 = 40A TESLA BAT. 24A x 1 = 24A x 1.25 = 30A TOTAL 56A x 1.25 = 70A 200A x 1.2 = 240A 240A - 150A = 90A 70A <= 90A PCS 70A BREAKER E (N) CRITICAL LOADS PANEL 125A BUSS, 120/240V, 1PH, 3W D C 1 STRING OF 13 H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Ca i r n s R e s i d e n c e 20196 33 1 A r r o w h e a d D r Pa l m D e s e r t , C A 9 2 2 1 1 06/03/2020 SF MJR Sheet Michael Rango PV-3.0 SI N G L E L I N E D I A G R A M NTS MOUNT DETAIL KEYNOTE: RACK MOUNT COMPONENTS 1.1 PHOTOVOLTAIC MODULE 1.2 UNIRAC "SOLARMOUNT" SUPPORT RAIL 1.3 SS RAIL T-BOLT AND NUT 1.4 SUNMODO L-FOOT W/FLASHING 1.5 3-1/2" SS LAG SCREW (3" MIN EMBEDMENT) STRUCTURAL 2.1 COMPOSITION SHINGLE ROOF COVERING 2.2 1/2" OSB ROOF DECKING 2.3 2 x 4 RAFTER H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Ca i r n s R e s i d e n c e 20196 33 1 A r r o w h e a d D r Pa l m D e s e r t , C A 9 2 2 1 1 06/03/2020 SF MJR Sheet Michael Rango PV-4.0 AT T A C H M E N T D E T A I L 1" = 18" CONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTING ALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BE INSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. CEC ARTICLES 690.56(B) AND 705.10. PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN CAUTION: SOLAR CIRCUIT WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAYBE ENERGIZED IN THE OPEN POSITION PLACE ON PANELS AND DISCONNECTS CONDUITS AND RACEWAYS EVERY 10' DC DISCONNECTS AND J-BOXES CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PLACE ON MSP WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE ADJACENT TO BACK FED BREAKER PLACE ON DC DISCONNECT WARNING ! ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RATED MPP CURRENT 18.82A RATED MPP VOLTAGE 380V MAX SYSTEM VOLTAGE 480V SHORT CIRCUIT CURRENT 30A FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALL LETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B)(2) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS CEC 690.56(C)(1)(A) Label for PV Systems that shut down the array and the conductors leaving the array. The title “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” shall utilize capitalized characters with a minimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall be capitalized with a minimum height of 4.8 mm (3∕16 in.) in black on white background. THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR PANELS ON ROOF LEGEND: HOT PURPLE ENERGY 760.322.4433 CAUTION N 1 SERVICE PANEL (YOU ARE HERE)2 ESS AC DISCONNECT 4 GATEWAY 5 CRITICAL LOADS PANEL 7 GENERATION COMBINER 8 BATTERY 6 ESS AC DISCONNECT 3 SYSTEM AC DISCONNECT 9 PV INVERTER PV SYSTEM AC DISCONNECT WARNING - DUAL POWER SOURCE SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM MAX AC CURRENT : 32 A AC VOLTAGE : 240 V PLACE ON GENERATION COMBINER PANEL PLACE ON SYSTEM DISCONNECTS PLACE ON BU/CRITICAL LOADS PANEL PV SYSTEM DISCONNECT PLACE ON PV SYSTEM DISCONNECT BACK UP CRITICAL LOADS PANEL WARNING - MULTIPLE POWER SOURCES PV AND BATTERY COMBINER PANEL AC DISCONNECT - MAIN BREAKER MAX AC CURRENT : 56 A AC VOLTAGE : 240 V GENERATION COMBINER PANEL WARNING - MULTIPLE POWER SOURCES PV AND BATTERY COMBINER PANEL AC DISCONNECT - MAIN BREAKER MAX AC CURRENT : 56 A AC VOLTAGE : 240 V ESS SAFETY DISCONNECT WARNING - DUAL POWER SOURCE MAX AC CURRENT : 24 A AC VOLTAGE : 240 V DISCONNECT 2 OF 2 ESS SAFETY DISCONNECT WARNING - DUAL POWER SOURCE MAX AC CURRENT : 24 A AC VOLTAGE : 240 V DISCONNECT 1 OF 2 PLACE ON ESS DISCONNECT AT BATTERY PLACE ON ESS DISCONNECT AT MSP H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Ca i r n s R e s i d e n c e 20196 33 1 A r r o w h e a d D r Pa l m D e s e r t , C A 9 2 2 1 1 06/03/2020 SF MJR Sheet Michael Rango PV-5.0 WA R N I N G L A B E L S NTS Electrical load calculation prepared for: 331 Arrowhead MAIN PANEL WEST SECTION OF SWITCHGEAR 3,402 sq-ft at 3 watts 10,206 VA Oven 6,000 VA Kitchen Microwave 1,250 VA Kitchen Hood Vent 600 VA Dishwasher 1,108 VA Disposal 950 VA Kitchen Refrigerator 1,500 VA Clothes Dryer (gas)1,032 VA Clothes Washer 1,308 VA FAU (3X 1,440VA) 4,320 VA Pool Pump 3,200 VA Total:31,474 VA First 10 KW @ 100 %10,000 VA Remainder 21,474.0 VA Remainder @ 40%8,589.6 VA Calculated general load 18,589.6 VA General load 18,589.6 VA A/C #1 6,288 VA A/C #2 4,464 VA A/C #3 6,288 35,629.6 VA watts to amps @240V 148.4567 Amps Total Amps provided: 150 Amps