HomeMy WebLinkAboutREVISION 1- PLAN.pdfA B D E L C I R C L E E X I S T I N G R E S I D E N C E E X I S T I N G G A R A G E 1. ALL WORK,MATERIALS AND METHODS SHALL BE IN CONFORMANCE WITH THE 2019 CBC CODES, 2019 CPC, 2019 CMC AND 2019 CEC CODE EDITIONS. ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT LOCATION. 2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND EXISTING CONDITIONS THEREON BEFORE COMMENCING WORK. REPORT ANY DISCREPANCIES AND/OR POTENTIAL PROBLEMS TO THE ARCHITECT PRIOR TO PROCEEDING WITH AFFECTED WORK. 3. CONTRACTORS ARE RESPONSIBLE FOR ALL WORK REGARDLESS OF THE LOCATION OF THE INFORMATION OF THE DOCUMENTS. 4. PROVIDE PIPE GUARDS AT ALL ABOVE GROUND UTILITY EQUIPMENT AS DICTATED BY GOVERNING AGENCIES. 5. PROVIDE PEDESTRIAN OR VEHICULAR PROTECTION BARRICADES TEMPORARY GUARD RAILS, AND / OR CANOPIES AS REQUIRED BY THE LOCAL AGENCIES OR AS NECESSARY FOR PEDESTRIAN AND VEHICULAR SAFETY. 6. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR COORDINATION AMONG HIS VARIOUS SUBCONTRACTORS. 7. IN THE EVENT OF DISCREPANCIES BETWEEN ANY DRAWINGS AND/OR SPECIFICATIONS, THE MORE COSTLY OR MORE RESTRICTIVE CONDITIONS SHALL BE DEEMED THE CONTRACT REQUIREMENT, UNLESS OTHERWISE STATED IN WRITING, FROM THE DESIGNER. GENERAL CONTRACTOR SHALL COORDINATE ALL UNDERGROUND ITEMS WITH THE PLUMBING, ELECTRICAL, GAS DRAWINGS . CONTRACTOR SHALL VERIFY DIMENSIONS OF ALL EQUIPMENT MANUFACTURERS. 8. GENERAL CONTRACTOR SHALL NOTIFY ALL APPLICABLE LOCAL GOVERNING, AUTHORITIES AND UTILITIES PRIOR TO COVERING UP ANY WORK REQUIRING INSPECTION. 9. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS WHERE REQUIRED. 10. ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY SEALED WITH APPROPRIATE SEALANT MATERIAL. UNLESS OTHERWISE NOTED 11. ALL EXTERIOR AND INTERIOR EXPOSED METAL, TRIM, TREILLAGE,RAILINGS, MOLDING, FRAMES, CASTING, ETC., SHALL BE PAINTED. 12. ALL METALLIC UTILITY LINES SHALL BE CORROSION PROTECTION. 14. ALL CONSTRUCTION AND DETAILS SHALL COMPLY WITH THE CITY BUILDING CODE AND ITS ADOPTIONS, AND WITH ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL ORDINANCES. 15. ANY/ALL LUMBER IN CONTACT WITH CONCRETE FLOOR OR FOOTINGS SHALL BE F.G. REDWOOD OR PRESSURE TREATED . 16. ALL FRAMING LUMBER SHALL BE GRADE MARKED WITH QUALITY PER C.B.C. (CALIFORNIA BUILDING CODE) REQUIREMENTS. 18. ACCESSORY DWELLING UNITS (<1,200 SQUARE FEET) NEED NOT TO HAVE FIRE SPRINKLERS, WHETHER ATTACHED OR DETACHED, PROVIDED THE PRIMARY HOME DOES NOT HAVE A FIRE SPRINKLER SYSTEM. SENATE BILL 1069 19.EXISTING NON COMPLIANT FIXTURES (TOILETS THAT US MORE THAN 1.6 GALLONS OF WATER PER FLUSH, URINALS THAT USE MORE THAN ONE GALLON OF WATER PER FLUSH, SHOWERHEADS THAT HAVE A FLOW CAPACITY OF MORE THAN 2.5 GALLONS OF WATER PER MINUTE, AND INTERIOR FAUCETS THAT EMIT MORE THAN 2.2 GALLONS OF WATER PER MINUTE) SHALL BE REPLACED. CERTIFICATION OF COMPLIANCE SHALL BE GIVEN TO THE BUILDING INSPECTOR PRIOR TO FINAL PERMIT APPROVAL. CALIFORNIA SB407. 20. COMPLIANCE WITH THE DOCUMENTATION REQUIREMENTS OF THE 2019 ENERGY EFFICIENCY STANDARDS IS NECESSARY FOR THIS PROJECT. REGISTERED, SIGNED, AND DATED COPIES OF THE APPROPRIATE CF1R, CF2R, AND CF3R FORMS SHALL BE MADE AVAILABLE AT NECESSARY INTERVALS FOR BUILDING INSPECTOR REVIEW. FINAL COMPLETED FORMS WILL BE AVAILABLE FOR THE BUILDING OWNER. 21. A LICENSED ENGINEER OR SURVEYOR SHALL STAKE THE PROPERTY CORNERS OF THE SUBJECT LOT. AT THE TIME OF THE UNDERGROUND PLUMBING INSPECTION, AND PRIOR TO CALLING FOR ANY FOOTING INSPECTIONS FOR THESE PROJECTS, THE CONTRACTOR SHALL PROVIDE STRING LINES ALONG THE PROPERTY LINES ADJACENT TO THE PROPOSED WALL LINES OF THE NEW CONSTRUCTION. 22. EACH GENERAL ENGINEERING CONTRACTOR, GENERAL BUILDING CONTRACTOR, AND SWIMMING POOL CONTRACTOR SHALL FURNISH THE CITY WITH A LIST OF EACH SUBCONTRACTOR UNDER HIS CONTROL OR DIRECTION, AND EACH SUBCONTRACTOR SHALL HAVE OBTAINED A BUSINESS LICENSE BEFORE THE FINAL INSPECTION ON A BUILDING OR STRUCTURAL SHALL BE GIVEN BY THE BUILDING AND SAFETY DEPARTMENT. 23. EXTERIOR LANDINGS: THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED AND HAVE A MINIMUM OR 36-INCHES MEASURED IN THE DIRECTION OF EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT TO EXCEED ¼-INCH PER FOOT. LANDINGS OR FINISHED FLOORS SHALL NOT BE MORE THAN 1.5 INCHES LOWER THAN THE TOP OF THE THRESHOLD FOR OUTWARD SWINGING EXTERIOR DOORS OR 7.75” FOR DOORS THAT DO NOT SWING OUTWARDS. R311.3. PROJECT IS APPROVED UNDER CITY OF PALM DESERT PROPERTY OWNER: MICHAEL MOON 47312 ABDEL CIRCLE PALM DESERT, CA 92260 PROJECT ADDRESS 47312 ABDEL CIRCLE PALM DESERT, CA 92260 APN: 630-360-006 LEGAL DESCRIPTION: LOT: 6 RECORDED BOOK/PAGE: MB 82/98 SUBDIVISION NAME:TR 5904 BLOCK: PROJECT AREAS LOT SIZE: 11,761 S.F. 0.270 AC. EXISTING LIVING AREA: 2,427.00 S.F. BUILDING DATA: ZONING: R-1-C OCCUPANCY TYPE: R3/U CONSTRUCTION TYPE: VB FIRE SPRINKLERS: NO YEAR BUILT: 1975 PROJECT DATA 1-800 TWO WORKING DAYS BEFORE YOU DIG 422-4133 Underground Service Alert Call: TOLL FREE YEAR ROUND 7:00AM TO 7:00PM ON WEEKDAYS 8:00AM TO 5:00PM ON SATURDAYS PROHIBITED ON SUNDAYS AND HOLIDAYS. CONSTRUCTION HOURS GENERAL NOTES DEPARTMENT OF CODE COMPLIANCE: ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT BUSINESS LICENCE PRIOR TO PERMIT ISSUANCE PER MUNICIPAL CODE, TITLE 5. ALL CONTRACTORS AND/OR OWNER-BUILDERS MUST SUBMIT CERTIFICATE OF WORKER'S COMPENSATION INSURANCE COVERAGE PRIOR TO THE ISSUANCE OF A BUILDING PERMIT PER CALIFORNIA LABOR CODE, SECTION 1800. GENERAL CONTRACTORS AND/OR OWNER-BUILDERS SHALL COMPLETE AND SUBMIT A CONTRACTOR'S LIST FROM THE DEPARTMENT OF CODE COMPLIANCE PRIOR TO REQUEST FOR FINAL INSPECTION. DEPARTMENT OF BUILDING AND SAFETY : APPROVED TEMPORARY SANITARY FACILITIES ( I.E. CHEMICAL TOILETS) SHALL BE IN THE CONSTRUCTION SITE PRIOR TO REQUEST FOR FIRST INSPECTION ). HEALTH AND SAFETY CODE SECTION 5406. CONTRACTOR AND/OR OWNER SHALL PROVIDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF ALL BUILDING MATERIALS. STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINED TO THE LOT FOR WHICH THE PERMIT IS ISSUED. ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR THIS PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS ON FILE WITH THIS OFFICE. THE PUBLIC RIGHT OF WAY SHALL BE MAINTAINED IN A CLEAR CONDITION AT ALL TIMES. 2019 CALIFORNIA BUILDING CODE CBC 2019 CALIFORNIA RESIDENTIAL CODE CRC 2019 CALIFORNIA MECHANICAL CODE CMC 2019 CALIFORNIA PLUMBING CODE CPC 2019 CALIFORNIA ELECTRICAL CODE CEC 2019 CALIFORNIA FIRE CODE CFC 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE CALGREEN 2019 CALIFORNIA ENERGY CODE CEC TITLE 24, PART 2, CALIFORNIA ADMINISTRATIVE CODE HANDICAP COMPLIANCE REGULATIONS AND ALL OTHER LOCAL CODES, ORDINANCES AND STATE AMENDMENTS. A1.10 TITLE SHEET / SITE PLAN SCOPE OF WORK RESIDENTIAL REMODEL: 1,000 SF KITCHEN REMODEL (3) BATHROOM REMODELS SHEET INDEX NO.SHEET NAME DESIGN A1.10 TITLE SHEET - SITE PLAN A2.10 EXISTING / DEMOLITION FLOOR PLAN A2.11 NEW FLOOR PLAN A3.10 ELEVATIONS M1.10 MECHANICAL PLAN M1.11 MECHANICAL NOTES E1.10 ELECTRICAL PLAN E1.11 ELECTRICAL NOTES P1.10 PLUMBING PLAN P1.11 PLUMBING NOTES S1.0 STRUCTURAL NOTES S1.1 STRUCTURAL NOTES S2.0 FOUNDATION PLAN S2.1 ROOF FRAMING PLAN S3.0 STRUCTURAL DETAILS S3.1 STRUCTURAL DETAILS T24 T24 ENERGY COMPLIANCE CALCULATIONS T24 T24 ENERGY COMPLIANCE CALCULATIONS VICINITY MAP MECHANICAL ELECTRICAL PLUMBING STRUCTURAL TITLE 24 “COMPLIANCE WITH THE DOCUMENTATION REQUIREMENTS OF THE 2019 ENERGY EFFICIENCY STANDARDS IS NECESSARY FOR THIS PROJECT. REGISTERED, SIGNED, AND DATED COPIES OF THE APPROPRIATE CF1R, CF2R, AND CF3R FORMS SHALL BE MADE AVAILABLE AT NECESSARY INTERVALS FOR BUILDING INSPECTOR REVIEW. FINAL COMPLETED FORMS WILL BE AVAILABLE FOR THE BUILDING OWNER.” SITE PLAN 11/8" = 1'-0" SCALE ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPR ODUCED O R MODIFI ED IN ANY WAY WIT HOUT THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEA SE IN ANY W A Y THE CO PYRIG HT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # REVISION 1 09/15/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 02 OWNER REVISION 09/15/2021 INDICATES TO BE REMOVED OR DEMOLISHED INDICATES TO REMAIN - PROTECT IN PLACE WALL LEGEND GARAGE ENTRY BEDROOM 3 LIVING ROOM DINING ROOM KITCHEN BATH 3 BEDROOM 1 BATH 1 BEDROOM 2 BATH 2 W.I.C. W.I.C. WH UTILITY CLOS. COVERED PATIO EXISTING SEWER LINE TO BE REMOVED EXISTING / DEMOLITION FLOOR PLAN 11/4" = 1'-0" SCALE A2.10 1.THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK. ANY DISCREPANCIES SHALL BROUGHT TO THE ATTENTION OF THE ENGINEER. NO DEMOLITION WORK SHALL COMMENCE WITHOUT FIELD VERIFICATION BY THE CONTRACTOR. 2.IT IS THE CONTRACTOR'S RESPONSIBILITY TO LOCATE AND REMOVE ALL MECHANICAL, ELECTRICAL, AND MISCELLANEOUS EQUIPMENT AS REQUIRED TO COMPLETE THE WORK. REFER TO MECHANICAL, PLUMBING, ELECTRICAL, AND STRUCTURAL DRAWINGS FOR DEMOLITION INFORMATION. 3.THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY STRUCTURAL BRACING AS REQUIRED DURING DEMOLITION AND CONSTRUCTION. 4.ANY PORTION OF THE PROJECT TO REMAIN WHICH IS DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITY, SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING CONDITION. 5.THE CONTRACTOR SHALL COORDINATE AND ARRANGE FOR THE DISCONNECTION OF ALL UTILITIES AND EQUIPMENT WITH THE OWNER AND UTILITY COMPANIES. THE CONTRACTOR SHALL CAP OFF ALL UNUSED UTILITIES. 6.THE CONTRACTOR SHALL REMOVE, DISCONNECT, AND SALVAGE ALL MECHANICAL, ELECTRICAL, AND MISCELLANEOUS WALL MOUNTED EQUIPMENT FOR RECONNECT AND REINSTALLATION. 7.THE CONSTRUCTOR SHALL ALLOW NO DEBRIS TO ACCUMULATE ON THE SITE. IMMEDIATELY REMOVE ALL DEBRIS AND SALVAGE FROM THE SITE. DEMOLITION NOTES EXISTING / DEMOLITION FLOOR PLAN ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPR ODUCED O R MODIFI ED IN ANY WAY WITHOUT THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEA SE IN ANY W A Y THE CO PYRIGHT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # REVISION 1 09/15/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 02 OWNER REVISION 09/15/2021 EXISTING WALL TO REMAIN - PROTECT IN PLACE WALL LEGEND NEW 2X4 WALL GARAGE ENTRY DEN LIVING ROOM DINING ROOM KITCHEN BATH 3 BEDROOM 1 BATH 1 BEDROOM 2 BATH 2 W.I.C. W.I.C. UTILITY CLOS. COVERED PATIO 7'-112"5'-312" 3'-012"3'-1112" 2' - 3 12" 7' - 0 12"9' - 4 " 3'-212"3'-11" 2'-7" 2' - 6 12" 4' - 0 " 6'-0" 3'-7" 3' - 7 " 3' - 7 12" B A C C E D F G I C C H 01 02 02 03 05 06 0606 0708 09 100 100 100 100 100 100 101 101 101 101 102 102 103 103 103 104 105 106 107 101 4' - 0 12" 108 J C 100 101 2'-412"3'-812" 2' - 9 " 1'-0" 1' - 0 " 21 ' - 8 12" 09 10 10 109 SYM. A WIDTH HEIGHT 7-0" DOOR SCHEDULE TYPE LOCATION GARAGE19'-0" SYM. 01 WIDTH 6'-0" HEIGHT 10'-0" TEMP.LOCATIONTYPE WINDOW SCHEDULE U-FACTOR SHGCOPER. XO SGD B 2'-8" C 2'-8" E 4'-0" F 2'-4" 8'-0" 8'-0" 10'-0" 8'-0" 0.36 0.24 D 5'-0"8'-0" G 3'-6"8'-0" 1.SELF CLOSING, SELF LATCHING, SOLID CORE OR LISTED 20 MINUTE ASSEMBLY, 1-HR RATED 2.NEW DOOR 3.EXISTING DOOR TO REMAIN YES H 2'-6"8'-0" I 3'-0"10'-0" HINGED HINGED HINGED POCKET QTY. BEDROOM 1 02 1'-6"7'-0"O FIX 0.36 0.24YES EXISTING WINDOWS, ENTRY 03 6'-0"10'-0"XO SGD 0.36 0.24YES DEN 05 3'-0"7'-0"O 0.36 0.24YES KITCHEN 06 8'-0"10'-0"0.36 0.24YES DINING ROOM, LIVING ROOM, 09 2'-0"10'-0"0.36 0.24YES BATH 2 FIXED XO SGD O 07 7'-3"10'-0"0.36 0.24YES BEDROOM 2XOSGD 08 3'-0"10'-0"0.36 0.24YES BEDROOM 2OFIX FIXED 1 1 1 1 3 1 1 2 PANEL ALUMINUM NOTES QTY. GARAGE SOLID CORE GARAGE BATH 1, BATH 2, BEDROOM 1, BEDROOM 2, LOUVERED SOLID CORE UTILITY ENTRY 3 SOLID CORE CLOSET LOUVERED HINGED LAUNDRY SOLID CORE BATH 3 SOLID CORE HINGED KITCHEN 1 1 1 3 2 1,3 3 3 3 2 2 HINGEDSOLID CORE 1 HINGED 1 5 1 1 1 J 5'-3"7'-0"SOLID CORE POCKET DEN 2 1 10 1'-6"10'-0"0.36 0.24YES BATH 1OFIXED 2 NEW FLOOR PLAN 100 KEYNOTES 101 102 NEW CABINETS WITH COUNTERTOP - FINISH AND MATERIAL TO BE SELECTED BY OWNER NEW SINK FIXTURE NEW SHOWER - 2664 SQ. IN. AREA SHALL BE MAINTAINED TO A POINT OF NOT LESS THAN 70 INCHES ABOVE THE SHOWER CPC 408.6. PROVIDE BACKING BOARD. SEE NOTES 1 AND 2 NEW TOILET - TO BE SELECTED BY OWNER MIN. 30" WIDE CLEAR SPACE AT WATER CLOSET EXTENDING AT LEAST 24" IN FRONT OF THE WATER CLOSET.. NEW RANGE WITH VENTED HOOD TO OUTSIDE NEW REFRIGERATOR NEW DRYER NEW WASHER GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN 1/2 INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE (AT WALLS). GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BY NOT LESS THAN 5/8 INCH TYPE 'X' GYPSUM BOARD. SECTION R302.6. 1 HR FIRE RATED EXTEND FROM FOUNDATION TO THE UNDERSIDE OF THE ROOF SHEATHING. NEW CMU INTERIOR WALL 103 105 NEW FLOOR PLAN 21/4" = 1'-0" SCALE 104 106 107 IMPORTANT NOTES: 1. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. CRC R307.2 2. GYPSUM BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER, OR IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. A2.11 108 ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPR ODUCED O R MODIFI ED IN ANY WAY WIT HOUT THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEA SE IN ANY W A Y THE CO PYRIGHT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # REVISION 1 09/15/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 02 OWNER REVISION 09/15/2021 DOOR AND WINDOW SCHEDULE 11/4" = 1'-0" SCALE 109 02 02 +0'-0" F.F. 3' - 0 " 10 ' - 0 " 302300 300 302 301 300 +0'-0" F.F. 301 300 KEYNOTES FRONT ELEVATION 11/4" = 1'-0" SCALE RIGHT ELEVATION 21/4" = 1'-0" SCALE A3.10 ELEVATIONS STUCCO TO MATCH EXISTING PAINT AND TEXTURE NEW WINDOW TO MATCH EXISTING WINDOW STYLE NEW DOOR TO MATCH EXITING DOOR STYLE 300 301 ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPR ODUCED O R MODIFI ED IN ANY WAY WIT HOUT THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEA SE IN ANY W A Y THE CO PYRIGHT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST PLAN CHECK 05/05/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 302 EXISTING MECHANICAL SUPPLY / RETURN LAYOUT TO REMAIN. IF ANY DUCTWORK NEEDS REPLACEMENT, USE DUCT R-8 VALUE. REPLACEMENT SHALL NOT EXCEED 40 LINEAR FEET M03 M01 M01 M02 M02 M02 MECHANICAL LAYOUT IS SCHEMATIC AND CAN BE RECONFIGURED BY GENERAL CONTRACTOR. 11/4" = 1'-0" SCALEMECHANICAL PLAN KEYNOTES RECESSED EXHAUST FAN - INTERMITTENT EXHAUST FAN - 100 CFM RECESSED RESIDENTIAL EXHAUST FAN - SHALL BE ENERGY STAR RATED AND SHALL BE CONTROLLED BY A HUMIDISTAT CAPABLE OF AN ADJUSTMENT BETWEEN 50 AND 80% HUMIDITY. CALGREEN 4.506.1. EXCEPTION: CONTROL BY A HUMIDISTAT IS NOT REQUIRED IF THE BATHROOM EXHAUST FAN IS ALSO THE DWELLING WHOLE HOUSE VENTILATION. SONE VALUE WILL NOT BE GREATER THAN 1.0 RECESSED EXHAUST FAN - INTERMITTENT EXHAUST FAN - 50 CFM RECESSED RESIDENTIAL EXHAUST FAN - SHALL BE ENERGY STAR RATED AND SHALL BE CONTROLLED BY A HUMIDISTAT CAPABLE OF AN ADJUSTMENT BETWEEN 50 AND 80% HUMIDITY. CALGREEN 4.506.1. EXCEPTION: CONTROL BY A HUMIDISTAT IS NOT REQUIRED IF THE BATHROOM EXHAUST FAN IS ALSO THE DWELLING WHOLE HOUSE VENTILATION. SONE VALUE WILL NOT BE GREATER THAN 1.0 NEW DRYER - SEE DRYER VENT DETAIL 2/M1.11 M02 M03 M01 M1.10 MECHANICAL PLAN ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E R EPRODUCED OR MODIFIED IN ANY WAY W ITHO UT THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY D O E S N O T R E LE ASE I N AN Y W AY THE COPYR IGHT AN D OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST PLAN CHECK 05/05/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 LOCAL VENTILATION EXHAUST REQUIREMENTS (FROM ASHRAE 62.2) LOCAL MECHANICAL EXHAUST FANS SHALL BE INSTALLED IN EACH KITCHEN AND BATHROOM ACCORDING TO THE REQUIREMENTS OF ASHRAE 62.2 THE MINIMUM AIRFLOW RATES SHALL BE GREATER THAN OR EQUAL TO THE AMOUNT INDICATED IN TABLE 5.1 BELOW AND FAN SONE RATINGS MUST NOT EXCEED 3.0 VENTED RANGE HOOD REQUIRED IF EXHAUST FAN FLOW(S) LESS THAN 5 ACH * IF THE RANGE HOOD IS USED FOR LOCAL EXHAUST IT MUST BE VENTED TO THE OUTDOORS AIR CHANGES PER HOUR 9ACH), WHICH IS DETERMINED BY MULTIPLYING THE VOLUME OF THE SPACE BY (5) ACH = CUBIC FEET PER HOUR, AND THEN DIVING BY 60 MINUTES PER HOUR TO DETERMINE THE CUBIC FEET PER MINUTE (CFM) INCLUDE THE REQUIRED HUMIDITY CONTROLS FOR THE BATHROOM EXHAUST FANS (CRC 303.3.1.) TABLE 5.1 - MINIMUM INTERMITTENT LOCAL VENTILATION EXHAUST AIRFLOW RATES LOCATION AIRFLOW NOTES KITCHEN 100 CFM BATHROOMS 50 CFM RESIDENTIAL BATHROOM EXHAUST FANS SHALL BE ENERGY STAR RATED AND SHALL BE CONTROLLED BY A HUMIDISTAT CAPABLE OF AN ADJUSTMENT BETWEEN 50 AND 80% HUMIDITY. CALGREEN 4.506.1 EXCEPTION: CONTROL BY HUMIDISTAT IS NOT REQUIRED IF THE BATHROOM EXHAUST FAN IS ALSO THE DWELING WHOLE HOUSE VENTILATION. MECHANICAL VENTILATION 3NTS SCALE M1.11 MECHANICAL NOTES 1.DRYER DUCT SHALL HAVE A BACK DRAFT DAMPER PER 2019 CMC 2.DRYER DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FT. INCLUDING TWO 90 DEGREE ELBOWS. TWO FEET SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO. 3.PROVIDE SMOOTH METAL DUCT FOR DRYER EXHAUST PER 2019 CMC. 4.THE CONTRACTOR SHALL DETERMINE ALL SIZES OF DUCT WORK, SUPPLY AND RETURN AIR REGISTERS SHOWN ON THE DRAWINGS. THIS CONTRACTOR SHALL ALSO VERIFY SIZES AND CAPACITIES OF THE SPECIFIED H.V.A.C. UNITS IN COMPLIANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ARCHITECTURAL DESIGN DRAWINGS. 5.HEATING DESIGN LOADS SHALL BE DETERMINED IN ACCORDANCE WITH ONE OF THE PROCEDURES DESCRIBED IN THE LATEST EDITION OF THE ASHRAM HANDBOOK OF FUNDAMENTALS, CHAPTERS 21 AND 22, OR AN EQUIVALENT COMPUTING PROCEDURE. NO CREDIT SHOULD BE GIVEN FOR THE FIREPLACE. 6.ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES AND REGULATIONS OF THE STATE FIRE MARSHAL; THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL SAFETY; THE NATIONAL ELECTRIC CODE; THE UNIFORM PLUMBING CODE, PUBLISHED BY THE WESTERN PLUMBING OFFICIALS ASSOCIATION; AND OTHER APPLICABLE STATE LAWS OR REGULATIONS. NOTHING IN THE PLANS OR SPECIFICATIONS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 7.HEATING AND AIR CONDITIONING SYSTEMS SHALL BE SIZED, DESIGNED AND EQUIPMENT SELECTED USING THE FOLLOWING METHODS. A.THE HEAT LOSS AND HEAT GAIN IS ESTABLISHED ACCORDING TO ANSI/ACCA 2 MANUAL J - 2011 (RESIDENTIAL LOAD CALCULATION). ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE METHODS. B.DUCT SYSTEMS ARE SIZED ACCORDING TO ANSI/ACCA 1 MANUAL D - 2014 (RESIDENTIAL DUCT SYSTEMS), ASHRAE HANDBOOKS OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. C.SELECT HEATING AND COOPING EQUIPMENT ACCORDING TO ANSI/ACCA 3 MANUAL S - 2014 (RESIDENTIAL EQUIPMENT SELECTION) OR OTHER EQUIVALENT DESIGN SOFTWARE OR METHODS. EXCEPTION: USE OF ALTERNATE DESIGN TEMPERATURES NECESSARY TO ENSURE THE SYSTEMS FUNCTIONS ARE ACCEPTABLE. IMPORTANT NOTE: EXISTING HVAC EQUIPMENT IS BEING RELOCATED. ALL EXISTING DUCTS THAT ARE NOT TO BE IN USE ARE TO BE ABANDONED. 8.AN ELECTRONICALLY SIGNED AND REGISTERED CERTIFICATE(S) OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (CF3R) SHALL BE POSTED AT THE BUILDING SITE BY A CERTIFIED HERS RATER. A REGISTERED CF3R WILL HAVE A UNIQUE 25-DIGIT REGISTRATION NUMBER OF THE ASSOCIATED CF2R. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL CF3R IS REVIEWED AND APPROVED. 9.AIR DUCT WILL BE PROVIDED WITH A MINIMUM INSULATION OF R-8 AS REQUIRED PER ENERGY COMPLIANCE DOCUMENTS. 10.EXHAUST DUCTS SHALL TERMINATE 3'-0" FROM OPENINGS INTO THE BUILDING. CMC 502.2.1 11/4" = 1'-0" SCALEMECHANICAL PLAN DRYER VENT 2NTS SCALE CONNECT TO DRYER 4" DIA. UP OR STRAIGHT THROUGH WALL SMOOTH INTERIOR SURFACE MAXIMUM LENGTH OF 14' WITH A MAXIMUM OF (2) 90 DEGREE ELBOWS. (2) FEET SHALL BE DECREASE FOR EACH BEND MORE THAN (2), UNLESS APPROVED BY THE BUILDING OFFICIAL. (CMC 504.3.1.2) DRYER VENT WITH PLASTER STOP AND FLAP ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPRODU CED OR MODIFI ED IN A NY WAY WITHOU T THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NO T RE LEA SE IN ANY W A Y THE COPYR IGHT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST PLAN CHECK 05/05/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 VS 3 3 VS VS GFCI GFCI GFCI GFCI GFCI REF GFCI GFCI GFCI RANGE GFCI GFCI GFCIGF C I AF C I SC SC SC SC SC 6" PENDANT LIGHT FIXTURE LED (INSEPARABLE SSL) HIGH EFFICACY FIXTURE 16 WATTS. DIMMING CONTROLS 6" RECESSED LED DOWN LIGHT FIXTURE LED (INSEPARABLE SSL) HIGH EFFICACY FIXTURE 16 WATTS. DIMMING CONTROLS SURFACE MOUNTED LIGHT FIXTURE LED (INSEPARABLE SSL) HIGH EFFICACY FIXTURE 16 WATTS. RECESSED RESIDENTIAL EXHAUST FAN - INTERMITTENT EXHAUST FAN - 50 CFM BATHROOM 100 CFM KITCHEN / LAUNDRY SHALL BE ENERGY STAR RATED AND SHALL BE CONTROLLED BY A HUMIDISTAT CAPABLE OF AN ADJUSTMENT BETWEEN 50 AND 80% HUMIDITY. CALGREEN 4.506.1. EXCEPTION: CONTROL BY A HUMIDISTAT IS NOT REQUIRED IF THE BATHROOM EXHAUST FAN IS ALSO THE DWELLING WHOLE HOUSE VENTILATION. SONE VALUE WILL NOT BE GREATER THAN 1.0 SINGLE POLE SWITCH - WALL MOUNTED @ 42" 3-THREE WAY D-DIMMER VS-VACANCY SENSOR DUPLEX WALL OUTLET WITH GROUND FAULT CIRCUIT INTERRUPTER DUPLEX WALL OUTLET WITH ARC FAULT CIRCUIT INTERRUPTER COMBINATION CARBON MONOXIDE DETECTOR / SMOKE DETECTOR (120V) WALL MOUNTED 12" BELOW CEILING HARDWIRED WITH BATTERY BACK UP AND AUDIBLE ALARM. "FIREX" 12000 SERIES "FADCM". EXISTING 200 AMP MAINPANEL SC 3 4 GFCI AFCI E1.10 ELECTRICAL LAYOUT IS SCHEMATIC AND CAN BE RECONFIGURED BY GENERAL CONTRACTOR. ELECTRICAL PLAN 11/4" = 1'-0" SCALE ELECTRICAL PLAN LEGEND ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPR ODUCED O R MODIFI ED IN ANY WAY WIT HOUT THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEA SE IN ANY W A Y THE CO PYRIG HT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST PLAN CHECK 05/05/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 01 METER / MAIN MAIN 200 AMP CONDUIT PER IID /SCE M #4 CU GROUND TO UFER 3/0 CU TO GAS & WATER GENERAL LIGHTING AT 3W/ S.F. 3W / 2,427 S.F.=7,281 SMALL APPLIANCE CIRCUITS AT 1,500W EA.2/ 1,500 =3,000 VENT HOOD AT 750W EA.1/ 750 = 750 LAUNDRY CIRCUIT AT 1,500W EA.1/ 1,500 = 1,500 DISHWASHER AT 1,500W EA.1/ 1,500 = 1,500 DRYER AT 5,400W EA.1/ 5,400 = 5,400 SUBTOTAL =19,431 1ST 10,000W AT 100%= 10,000 REMAINING AT 40%= 3,773 6.0 TONS REQUIRED AT 2,016W / TON 2,016W/ 6 TONS = 12,096 TOTAL = 25,869 MAIN SERVICE: 25,869W / 240V = 108 AMPS USE 200AMP MAIN PANEL - CONTRACTOR TO VERY MINIMUM REQUIREMENTS E1.11 ELECTRICAL LAYOUT IS SCHEMATIC AND CAN BE RECONFIGURED BY GENERAL CONTRACTOR. ELECTRICAL NOTES 1. ALL 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS (NEW, MODIFIED, REPLACED, OR EXTENDED) SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT OR BY ANY OF THE OTHER MEANS DESCRIBED IN 210.12(A)(2) THROUGH (6). (CEC 210.12(A)) 2. ALL INTERIOR AND EXTERIOR LIGHT FIXTURES SHALL BE A HIGH EFFICACY TYPE FIXTURE AND HAVE A CONTROL DEVICE / SYSTEM IN ACCORDANCE WITH THE 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS / TITLE 24, SECTION 150.0(K)) 3. KITCHEN RECEPTACLES AT KITCHEN COUNTER SHALL BE INSTALLED ABOVE THE SPLASH OR DIRECTLY IN THE SPLASH IF THE SPLASH EXTENDS ABOVE 6". GFCI RECEPTACLES SHALL BE INSTALLED EVERY 48" ON CENTER. COORDINATE ALL LOCATIONS PRIOR TO INSTALLING ROUGH-IN-BOXES. 4. PROVIDE RECEPTACLE FOR THE MICROWAVE APPLIANCE. PROVIDE DEDICATED 20AMP CIRCUIT. 5. RECEPTACLES FOR REFRIGERATOR SHALL BE INSTALLED +48" ABOVE FINISHED FLOOR. PROVIDE A 20AMP DEDICATED CIRCUIT FOR EACH APPLIANCE. 6. MOUNT SWITCHES AND CONVENIENCE OUTLETS AT KITCHEN, BATHROOMS, AND LAUNDRY ROOM COUNTERS HORIZONTALLY AT 40" ABOVE SLAB TO CENTER OF PLATE. 7. ALL FIXED APPLIANCES SHALL BE SECURELY FASTEN IN PLACE. 8. PROVIDE AT LEAST TWO 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS TO SERVE KITCHEN, BREAKFAST ROOM, AND DINING ROOM. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. 9.FOR GARBAGE DISPOSAL AND DISHWASHER, INSTALL A HALF SWITCHED DUPLEX RECEPTACLE AND INSTALL BELOW SINK. CONNECT THESWITCHED SIDE OF THE RECEPTACLE TO A MOTOR RATED WALL SWITCH OR TO THE SINK MOUNTED AIR SWITCH AND PROVIDE A DEDICATED CIRCUIT FOR EACH APPLIANCE WITH A COMMON TRIP DEVICE. 10.PROVIDE A JUNCTION BOX WITH PROPER SUPPORTS FOR PENDANT LIGHT FIXTURES. 12.MOUNT CONVENIENCE RECEPTACLES HORIZONTALLY WITH BOTTOM OF BOX 3' ABOVE SLAB. 13.ALL CONVENIENCE OUTLETS TO BE ON GFI SEPARATE FROM INTERIOR G.F.I. PROTECTED CIRCUITS. 14.TYPICAL LIGHT SWITCH MOUNTING HEIGHT TO BE 37" ABOVE SLAB TO CENTER OF PLATE. MOUNT SWITCHES AND CONVENIENCE OUTLETS AT KITCHEN, BATHROOMS, AND LAUNDRY ROOM COUNTERS HORIZONTALLY AT 40" ABOVE SLAB TO CENTER OF PLATE. 15.ALL SMOKE DETECTORS & CARBON MONOXIDE ALARMS ARE TO REMAIN. IF ANY ARE TO BE REPLACED, PROVIDE A INVENSYS "FIREX" 12000 SERIES "FADCM" SMOKE & CARBON MONOXIDE ALARM. DETECTORS SHALL BE CONNECTED TOGETHER WITH YELLOW WIRE AND ALL CONNECTED TO A COMMON DEDICATED CIRCUIT. DETECTORS SHALL BE PROVIDED WITH A BATTER BACKUP AND AUDIBLE ALARM. PROVIDE PROVISIONS TOLOCK-ON THE SMOKE DETECTOR CIRCUIT BREAKER. INTERCONNECTED SO THAT THE ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OTHER ALARMS IN THE DWELLING UNIT. 16.SINGLE OR MULTIPLE STATION SMOKE ALARM/CARBON MONOXIDE ALARMS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA, IN THE IMMEDIATE VICINITY OF BEDROOMS, IN EACH ROOM USED FOR SLEEPING PURPOSES,IN ENCLOSED COMMON STAIRWELLS OF APARTMENT COMPLEXES AND OTHER MULTIPLE-DWELLING COMPLEXES. 17.EXHAUST FANS LOCATED IN BATH AND SHOWER AREAS SHALL BE CONTROLLED BY A HUMIDISTAT. THE HUMIDISTAT SHALL BE ACCESSIBLE. 18.EXHAUST FANS FOR KITCHENS SHALL BE A MINIMUM OF 100 CFM. 19.LUMINARIES (LIGHT FIXTURES), LIGHTING OUTLETS, AND/OR CEILING FANS LOCATED OVER SPA OR HOT TUB OR WITHIN 5 FEET OF THE INSIDE WALLS OF THE SPA OR HOT TUB SHALL BE A MINIMUM OF 7'-6" ABOVE THE MAXIMUM WATER LEVEL AND SHALL BE PROTECTED BY A GROUND-FAULT CIRCUIT INTERRUPTER. LUMINARIES SHALL BE SUITABLE FOR DAMP. LOCATIONS PER CEC 2016. 20.RECEPTACLE OUTLET LOCATIONS WILL COMPLY WITH CEC ARTICLE 210.52 A.TAMPER RESISTANT RECEPTACLES FOR ALL LOCATIONS DESCRIBED IN 210.52 (I.E., ALL RECEPTACLES IN A DWELLING.) B.WEATHER RESISTANT TYPE FOR RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS (OUTSIDE) C.ARC-FAULT PROTECTION FOR ALL OUTLETS (NOT JUST RECEPTACLES) LOCATED IN ROOMS DESCRIBED IN NEC 210.12(A): KITCHENS, LAUNDRY AREAS, FAMILY, LIVING, BEDROOMS, DINING, HALLS, ETC. D.GFCI PROTECTED OUTLETS FOR LOCATIONS DESCRIBED IN NEC 210.8(A): LAUNDRY AREAS, KITCHEN DISHWASHERS, KITCHENS, GARAGES, BATHROOMS, OUTDOORS, WITHIN 6' OF A SINK, ETC. E.PROVIDE AT LEAST ONE 20A BRANCH CIRCUIT TO SERVE LAUNDRY OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. CEC210.11(C) (3) 21.ALL 15 AND 20 AMPERE RECEPTACLES SHALL BE TAMPER RESISTANT. 22.ALL LIGHTING SHALL BE HIGH EFFICACY (FLUORESCENT, LED). LED LIGHTING SYSTEMS AND GU-24 LAMP HOLDER SHALL BE LISTED BY ENERGY COMMISSION AND SHALL MEET THE REQUIREMENTS OF TABLE 150-C. WATTS LUMENS/WATTS 5. AT LEAST ONE WALL RECEPTACLE OUTLET SHALL BE INSTALLED WITHIN 3 FEET OF THE EDGE AND ADJACENT TO EACH BASIN LOCATION AND SHALL BE GFCI PROTECTED. THE OUTLET SHALL BOT BE INSTALLED IN A FACE UP POSITION. 6. PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE IS REQUIRED AT SHOWER AND / OR TUB SHOWER COMBINATIONS. 7. GLAZING IN ENCLOSURES FOR WET SURFACES (TUBS AND SHOWERS) WITHIN 60" RADIUS SHALL BE TEMPERED SAFETY GLAZING. 8. GLAZING IN ANY PORTION OF A BUILDING WALL , WHERE THE BOTTOM OF THE GLAZING IS LESS THAN 60" ABOVE A STANDING SURFACE AND DRAIN INLET SHALL BE TEMPERED SAFETY GLAZING. 9. ALL FANS EXHAUST 3' FEET AWAY FROM AN EXTERIOR OPENING. 10. ALL LIGHTS OVER SHOWER OR BATHTUB ENCLOSED BY WALLS AND ENCLOSURES SHALL BE MARKED " SUITABLE FOR WET LOCATIONS". ALL LIGHTS OVER A BATHTUB WITH NO ENCLOSURE SHALL BE MARKED "SUITABLE FOR DAMP LOCATIONS". NO RECEPTACLES ARE PERMITTED IN A BATHTUB OR SHOWER SPACE. 11. SMOKE DETECTORS IN ALL BATHROOMS, CENTRALLY LOCATED IN AREAS LEADING TO BEDROOMS, ONE AT EACH STORY, AND ONE IN BASEMENT. 12. CARBON MONOXIDE ALARMS ARE REQUIRED IN AREAS LEADING TO BEDROOMS AND ON EACH FLOOR LEVEL. 13. ALL KNOB TUBE WIRING THAT IS EXPOSED WHEN WALLS ARE OPENED IS TO BE REMOVED BACK TO THE ATTIC OR UNDER FLOOR ACCESSIBLE SPACES AND SPLICED IN A JUNCTION BOX WITH ROMEX, OR OTHER APPROVED WIRING METHOD, TO BE RUN BACK TO THE ORIGINAL LOCATION. KNOB TUBE BOXES MUST BE REPLACED TO ACCOMMODATE NEW WIRING TYPE. IF REMOVAL OR WIRING WOULD NECESSITATE OPENING OF ADDITIONAL WALLS NOT IN SCOPE, AND THE WIRING IS IN SOUND CONDITION, THEN IT MAY REMAIN. 5 OR LESS >5 TO 15 >15 TO 40 OVER 40 30 45 60 90 22. IN EXISTING DWELLINGS WHEN AN ADDITION, ALTERATION, OR REPAIR IS MADE WITH COST EXCEEDING $1000, SMOKE ALARMS ARE REQUIRED TO BE INSTALLED AT LOCATIONS INDICATED BELOW. RETROFIT SMOKE ALARMS MAY BE BATTERY OPERATED AND NOT INTERCONNECTED WHERE POWER AND INTERCONNECTION WOULD REQUIRE THE REMOVAL OF WALL OR CEILING FINISHES, AT LOCATIONS WHERE BATTERY POWERED SMOKE ALARMS ARE ALREADY INSTALLED, OR WHERE REPAIRS OR ALTERATIONS ARE LIMITED TO THE EXTERIOR OF THE BUILDING, INCLUDING THE ADDITION OF PORCHES OR DECKS, OR CONSIST ONLY OF PLUMING, ELECTRICAL AND MECHANICAL WORK NOT REQUIRING THE REMOVAL OF INTERIOR WALL OR CEILING FINISHES. IN EACH SLEEPING ROOM AND CENTRALLY LOCATED IN ROOMS AND CORRIDORS GIVING DIRECT ACCESS TO EACH SLEEPING AREA. ON EACH STORY OF MULTISTORY DWELLINGS INCLUDING BASEMENTS AND HABITABLE ATTICS. 1.ALL PERMANENT LIGHTING IN BATHROOMS THAT ARE TO BE REMODELED SHALL BE HIGH EFFICACY (E.G. FLUORESCENT) OR SHALL BE CONTROLLED BY A MOTION SENSOR. 2.ALL LIGHT FIXTURES THAT ARE TO BE RECESSED INTO INSULATED CEILINGS (CAN LIGHTS) SHALL BE INSULATED CONTACTED (I.C.) RATED SO THAT INSULATION CAN BE PLACED OVER THEM. THE LIGHT FIXTURE HOUSING SHALL BE AIRTIGHT TO PREVENT CONDITIONED ARE ESCAPING INTO THE ATTIC OR CEILING CAVITY AND UNCONDITIONED ARE INFILTRATING FROM THE ATTIC OR CEILING CAVITY INTO THE CONDITIONED SPACE. 3.AT LEAST ONE 20-AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY THE BATHROOM RECEPTACLE OUTLET(S). 4.OUTLETS FOR OTHER EQUIPMENT WITHIN THE SAME BATHROOM SHALL BE PERMITTED TO BE SUPPLIED FROM THE 20-AMP BRANCH CIRCUIT WHEN THE CIRCUIT SUPPLIES A SINGLE BATHROOM. PANEL DIAGRAM 21/4" = 1'-0" SCALE ELECTRICAL CALCULATIONS 31/4" = 1'-0" SCALE 1.ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH ES TABLE 150.0-A. LIGHT SOURCES THAT ARE NOT MARKED "JA8-2016-E SHALL NOT BE INSTALLED IN ENCLOSED LUMINAIRES. ES 150.0(K) 2.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS AT LEAST ONE LUMINAIRE SHALL BE CONTROLLED BY A VACANCY SENSOR. 3.DIMMERS OR VACANCY SENSORS SHALL CONTROL ALL LED STYLE LUMINAIRES. TWO EXCEPTIONS: FIXUTRES INSTALLED IN HALLWAYS OR (CLOSETS UNDER 70 SF.) 4.RECESSED CAN LIGHT FIXTURES SHALL BE IC LISTED, AIR TIGHT LABELED, AND NOT BE EQUIPPED WITH A STANDARD MEDIUM BASE SCREW SHELL LAMP HOLDER. ES 150.0(K) 5.SFD OUTDOOR LIGHT FIXTURES THAT ARE ATTACHED TO A BUILDING ARE REQUIRED TO BE HIGH EFFICACY, BE MANUALLY ON/OFF SWITCH CONTROLLED, AND HAVE BOTH MOTION SENSOR AND PHOTOCELL CONTROL. SEE ES 150.0(K) 3 FOR ADDITIONAL CONTROL OPTIONS. 6.PROVIDE AT LEAST ONE 120V-20A BRANCH CIRCUIT TO SERVE BATHROOM RECEPTACLES. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. CEC210.11(C) (3) 7.PROVIDE AT LEAST ONE 20A BRANCH CIRCUIT TO SERVE LAUNDRY OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. CEC210.11(C) (3) 14.IF APPLICABLE: FOR A SINGLE-FAMILY DWELLING, THE SERVICE DISCONNECTING MEANS SHALL HAVE A RATING OF NOT LESS THAN 200 AMPERES WITH A SERVICE PANEL BUSS RATING OF A MINIMUM OF 225 AMPERES. THIS APPLIES TO BOTH NEW SFD’S AND ALL EXISTING SFD’S THAT ARE REPLACING THEIR ELECTRICAL SERVICES. 15. THERE WILL BE A MINIMUM OF 2 SMALL APPLIANCE BRANCH CIRCUITS WITHIN THE LOCATIONS SPECIFIED IN ARTICLE 210.52(B), I.E., KITCHEN AND DINING AREAS. 16. BATHROOM CIRCUITING SHALL BE EITHER: a)A 20-AMPERE CIRCUIT DEDICATED TO EACH BATHROOM, OR b)AT LEAST ONE 20 AMPERE CIRCUIT SUPPLYING ONLY BATHROOM RECEPTACLE OUTLETS. 17. PROVIDE DIMMING CONTROLS FOR LUMINAIRES NOT CONTROLLED BY OCCUPANCY VACANCY SENSORS ELECTRICAL NOTES 11/4" = 1'-0" SCALE ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPR ODUCED O R M ODIF IED IN ANY WAY WIT HOUT T HE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEA S E IN ANY W A Y T HE C O PYRIG HT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST PLAN CHECK 05/05/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 FIXTURE FAU BTU/H 100,000 APPROXIMATE GAS INPUT SYM. 01 INSTANTANEOUS WH02 199,000 03 04 DRYER 35,000 RANGE 65,000 USE EXISTING VENTS AND POINT OF CONNECTIONS USE EXISTING VENTS AND POINT OF CONNECTIONS U.N.O. 04 03 02 01 01 (E) GAS METER GREATEST LENGTH 50' 1-1/4" 1-1/4" 1/2" 1-1/4" 1" 1" 1" 1/2" 4" EXTEND AND CONNECT TO (E) 4" SEWER LATERAL. 3" 3" 3" 2" 2" 3" 3" 2" 3" P05 P03 P01 P04 P03 P00 P03 3" 2"2"2" P00 P03 P00 P03 4" EXTEND AND CONNECT TO (E) 4" SEWER LATERAL. GAS P.O.C - INDICATED ON PLAN WHETHER (N) OR (E) VENT / DRAIN ALL DOMESTIC HOT WATER PIPING TO HAVE THE FOLLOWING MINIMUM INSULATION INSTALLED: 1/2" PIPE (1/2" INSULATION); 3/4" PIPE (1" INSULATION); 1: TO 1-1/2" PIPE (1-1/2" INSULATION). CPC 609.11 & ES 150.0 (J) A.ADDITIONALLY, THE 1/2" HOT WATER PIPE TO THE KITCHEN SINK, AND THE COLD WATER PIPE WITHIN 5' OF THE WATER HEATER BOTH REQURIE 1" MINIMUM INSULATION. ES 150.0(J) BELOW GRADE HOT WATER PIPING IS REQUIRED TO BE INSTALLED IN A WATERPROOF AND NON CRUSHABLE SLEEVE OR CASING THAT ALLOWS FOR REPLACEMENT OF BOTH THE PIPING AND THE INSULATION. SEWER LINE - SIZE INDICATED ON PLANS GAS LINE - SIZE INDICATED ON PLANS P1.10 PLUMBING PLAN PLUMBING PLAN 1SCALE 1/4" = 1'-0" IT IS THE RESPONISBILITY OF THE CONTRACTOR TO VERIFY THE PIPE SIZING PER CBC, CMC, AND CPC ACCORDING TO APPLIANCE BTU AND DISTANCE FROM MAIN METER. 1-1/2" VENT UP 2" VENT UP 2" TRAPPED WASTE UP TO DRAIN 2" WASTE UP TO LAVATORY OR SINK 3" WASTE UP TO WATER CLOSET 3" CLEAN OUT P00 P01 P02 P03 P04 KEYNOTES P05 PLUMBING LEGEND ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPRODU CED O R MODIFI ED IN ANY WAY WITHOU T THE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RE LEA SE IN ANY W A Y THE COPYR IGHT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST PLAN CHECK 05/05/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH THE FOLLOWING 4.303.1.1 WATER CLOSETS: ≤1.28 GAL/FLUSH 4.303.1.2 WALL MOUNTED URINALS: ≤ 0.125 GAL/FLUSH; ALL OTHER URINALS ≤ 0.5 GAL/FLUSH 4.303.1.3.1 SINGLE SHOWERHEADS: ≤ 1.8 GPM @80 PSI 4.303.1.3.2 MULTIPLE SHOWERHEADS: COMBINED FLOW RATE OF ALL SHOWERHEADS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GPM @80 PSI, OR ONLY ONE SHOWER OUTLET IS TO BE IN OPERATION AT A TIME 4.303.1.4.1 RESIDENTIAL LAVATORY FAUCETS: MAXIMUM FLOW RATE ≤ 1.2 GPM @60 PSI; MINIMUM FLOW RATE ≥ 0.8 GPM @20 PSI 4.303.1.4.2 LAVATORY FAUCETS IN COMMON AND PUBLIC USE AREAS OF RESIDENTIAL BUILDINGS ≤ BUILDINGS ≤ 0.5 GPM @60 PSI 4.303.1.4.3 METERING FAUCETS: ≤ 0.25 GALLONS PER CYCLE 4.303.1.4.4 KITCHEN FAUCETS: ≤ 1.8 GPM @60 PSI; TEMPORARY INCREASE TO 2.2 GPM ALLOWED BUT SHALL DEFAULT TO 1.8 GPM 1. DESIGN AND CONSTRUCT COMPLETE PLUMBING SYSTEM CONSISTING OF DRAIN, VENT WASTE AND WATER LINES IN COMPLIANCE WITH ALL APPLICABLE STATE, LOCAL AND FEDERAL LAWS, CODES AND REGULATIONS. COMPLY WITH ARCHITECTURAL WORKING DRAWINGS FOR LOCATIONS OF ALL PLUMBING FIXTURES, TRIM AND RELATED ITEMS. 2. PERMITS AND INSPECTIONS: SHALL BE OBTAINED BY THIS CONTRACTOR AS REQUIRED BY LIMITS OF THE WORK DEFINED HEREIN AND BY APPLICABLE CODES AND REGULATIONS. 3. DESIGN DRAWINGS SHALL BE PREPARED BY THIS CONTRACTOR IN COMPLIANCE WITH THE PROJECT DESIGN AND IN COMPLIANCE WITH ALL APPLICABLE CODE REQUIREMENTS. SUBMIT PLUMBING DESIGN ISOMETRIC DRAWINGS TO THE BUILDING DEPARTMENT FOR APPROVAL AS PER THEIR REQUIREMENTS. 4. PROVIDE ALL PLUMBING WORK AS INDICATED ON THE DRAWINGS, SPECIFIED, HEREINAFTER CALLED FOR AND/OR REQUIRED TO COMPLETE THE PROJECT. PRINCIPAL ITEMS OF WORK INCLUDE THE FOLLOWING: 5. PLUMBING FIXTURES AND TRIM. 6. COLD WATER SYSTEMS CONSISTING OF ALL PIPING VALVES, CONTROLS AND ALL ACCESSORIES WITH FINAL CONNECTIONS TO ALL PLUMBING FIXTURES. 7. HOT WATER SYSTEMS, CONSISTING OF WATER HEATERS, CIRCULATING PUMPS, CONTROLS, PIPING, VALVES AND ALL ACCESSORIES INCLUDING FINAL CONNECTIONS. 8. ALL GAS PIPING AS REQUIRED. 9. ALL SOIL, WASTE AND VENT LINES SHALL COMPLY WITH UNIFORM PLUMBING CODE. SOIL AND WASTE BEYOND THE FIVE FOOT BUILDING LINE SHALL BE VITRIFIED CLAY PIPE WITH SPEED SEAL JOINTS OR TRANSIT SEWER PIPE WITH RING GROOVE COUPLINGS. 10. COLD AND HOT WATER LINES ABOVE GRADE SHALL BE TYPE M HARD DRAWN COPPER WITH 50-50 JOINTS. COLD WATER LINES BELOW GRADE SHALL BE TYPE L COPPER WITH 95-5 JOINTS FROM WATER METER. SOLDERING PROHIBITED UNDER CONCRETE FLOOR- 1 PIECE RUN. 11. PROVIDE ALL VALVES AS REQUIRED. SWEAT COPPER ENDS ON COPPER PIPING SYSTEMS, SCREWED ENDS ON STEEL SYSTEMS. USE SQUARE HEAD COCKS ON FUEL GAS SYSTEMS. PROVIDE SPEEDWAY STOPS ON ALL FIXTURES. 12. SUPPORT ALL LINES BY MEANS OF RESILIENT FITTING OR ACCESSORIES; DO NOT ALLOW PIPING TO BE IN DIRECT CONTACT WITH FRAMING. NO COPPER PIPING SHALL BE IN CONTACT WITH ANY METAL OTHER THAN COPPER. PIPING SYSTEMS SHALL BE SECURELY SUPPORTED TO PREVENT UNDUE MOVEMENT AND SWAYING BUT FLEXIBLE ENOUGH TO PERMIT EXPANSION. 13. SUPPORT ALL LINES BY MEANS OF RESILIENT FITTING OR ACCESSORIES; DO NOT ALLOW PIPING TO BE IN DIRECT CONTACT WITH FRAMING. NO COPPER 14. HOT MOPPED SHOWER PLAN SHALL BE INSPECTED UPON COMPLETION OF HOT-MOPPING AND SHALL BE FILLED WITH WATER FOR INSPECTION. (CPC 2016) 15. PROVIDE PRESSURE REGULATOR FOR WATER SERVICE WHERE STATIC PRESSURE EXCEEDS 80 PSI. (CPC2016) 16. PROVIDE A COMBINATION PRESSURE AND TEMPERATURE RELIF VALVLE AT ALL WATER HEATERS, SET TO OPEN AT NOT MORE THAN 150 PSI. DRAIN PIPE SHALL EXTEND TO OUTSIDE 17. ALL DOMESTIC HOT WATER PIPING TO HAVE THE FOLLOWING MINIMUM INSULATION INSTALLED: 1/2" PIPE (1/2" INSULATION); 3/4" PIPE (1" INSULATION); 1" TO 1-1/2" PIPE (1-1/2" INSULATION). CPC 609.11 & ES 150.0(J) 1.1.1.ADDITIONALLY, THE 1/2" HOT WATER PIPE TO THE KITCHEN SINK, AND THE COLD-WATER PIPE WITHIN 5' OF THE WATER HEATER BOTH REQUIRE 1" MINIMUM INSULATION. ES 150.0(J) 18. CONTROL VALVES IN SHOWERS, TUB/SHOWERS, BATHTUBS, AND BIDETS MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES. CPC SECTIONS 408, 409, 410. 19. WATER HEATERS 1.GAS PIPING SIZING BASED UPON A MINIMUM INPUT OF 200,000BTU/HR 2.A CONDENSATE DRAIN INSTALLED NO HIGHER THAN 2" ABOVE THE BASE OF THE HEATER THAT ALLOWS FOR GRAVITY DRAINAGE. 3.THE "B" VENT INSTALLED IN A STRAIGHT POSITION FROM THE ROOM CONTAINING THE WATER HEATER TO THE ROOF TERMINATION. (FOR FUTURE POSSIBLE SLEEVING FOR HIGH EFFICIENCY HEATER VENTING). 4.A 120 VOLT RECEPTACLE ACCESSIBLE TO THE HEATER INSTALLED WITHIN 3' 20 . INSTANTANEOUS WATER HEATERS SHALL HAVE ISOLATION VALVES ON BOTH THE COLD AND THE HOT WATER PIPING LEAVING THE WATER HEATER COMPLETE WITH HOSE BIBS OR OTHER FITTINGS ON EACH VALVE FOR FLUSHING THE WATER HEATER WHEN THE VALVES ARE CLOSED. ES 110.3 21. NON-COMPLIANT PLUMBING FIXTURES REPLACEMENT REQUIREMENTS EFFECTIVE JANUARY 1ST 2014, ALL BUILDINGS UNDERGOING PERMIT ALTERATIONS, ADDITIONS, OR IMPROVEMENTS SHALL REPLACE NON-COMLIANT PLUMBING FIXTURES WITH WATER CONSERVING PLUMBING FIXTURES. 22. PLUMBING FIXTURE REPLACEMENT IS REQUIRED PRIOR TO ISSUANCE OF COMPLETION, CERTIFICATE OF OCCUPANCY, OR FINAL PERMIT APPROVAL BY THE LOCAL BUILDING DEPARTMENT. 23. BACKING BEHIND SHOWERS AND TUBS - SHOWERS AND TUB / SHOWER SHALL HAVE SMOOTH, HARD, NON-ABSORBENT SURFACE (E.G., CERAMIC TILE OR FIBERGLASS) OVER MOISTURE RESISTANT UNDERLAYMENT. (E.G., W.R. GYP) TO A HEIGHT OF 6 FEET ABOVE THE DRAIN INLET CRC 307.2 P1.11 PLUMBING MATERIAL 3NTS SCALE PLUMBING NOTES IT IS THE RESPONISBILITY OF THE CONTRACTOR TO VERIFY THE PIPE SIZING PER CBC, CMC, AND CPC ACCORDING TO APPLIANCE BTU AND DISTANCE FROM MAIN METER. PLUMBING FIXTURES 2NTS SCALE PLUMBING NOTES 1NTS SCALE ALL DRAWING ARE THE PROPERTY OF MDESIGN GROUP INC., AND ARE ONLY TO BE USED AS AN INSTRUMENT OF S E R V I C E . T H E S E D R A W I N G S S H A L L N O T B E REPR ODUCED O R M ODIF IED IN ANY WAY WIT HOUT T HE W R I T T E N C O N S E N T F R O M M D E S I G N G R O U P I N C . SUBMISSION OF THESE DRAWINGS TO ANY THIRD PARTY DOES NOT RELEA S E IN ANY W AY T HE C O PYRIG HT AND OWNERSHIP OF DRAWINGS PROVISIONS LISTED HEREIN. STATUS DATE PROJECT # 1ST PLAN CHECK 05/05/2021 220052 SHEET NAME DESIGNER OWNER MICHAEL MOON ADDRESS 47312 ABDEL CIRCLE PALM PALM DESERT, CA 92260 PROJECT TYPE RESIDENTIAL REMODEL REVISIONS NO.DESCRIPTION DATE 74-818 VELIE WAY, STE 3 PALM DESERT, CA 92264 T: 760-219-3068 F: 760-219-3069 D R A F T I N G , D E S I G N , A N D P E R M I T S E R V I C E S M D E S I G N G R O U P , I N C . M D E S I G N A N D A S S O C I A T E S @ O U T L O O K . C O M 01 1ST PLAN CHECK 05/05/2021 ρ Copyright 2020. All rights reserved. The use of these plans, calculations and specifications shall be restricted to the original site for which they were prepared, and publication thereof is expressly limited to such use. Reproduction, publication or reuse by any method, in whole or part, is prohibited without the permission and consent of Elevated Design & Consulting. Title to the Plans, calculations and specifications shall constitute prima facie evidence of the acceptance of these restrictions. In the event of unauthorized reuse of the plans by a third party, the third party shall hold Elevated Design & Consulting. Note: Plans are not valid for construction unless approved by the corresponding municipal governing body. ∅ Ø ∅⅊ ∅ ⅊ ∅ ⅊ ∅ ⅊ ∅ ∅ ∅ R E V I S I O N BYMARKDATE SHEET OF 6 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 21-18 S.M. O.M.Sep. 15, 21 FR-1 MO O N R E S I D E N C E RE S I D E N T I A L R E M O D E L PR O J E C T A D D R E S S : 47 3 1 2 A B D E L C I R C L E PA L M D E S E R T C A 9 2 2 6 0 P. O . B O X 2 3 0 5 NO R W A L K , C A 9 0 6 5 1 EL E V A T E D D E S I G N & CO N S U L T I N G 9/5/21 FM C 90183 EXP. 9/30/21 R ERET ISGE P OISSFEORN E A RE E N I G N C LIVI C S ETA T FO AINROFILA L FAB I A N MEND O Z A D S1.0 1 STRUCTURAL NOTES ″× ″ ″× ″ ″× ″ ″ ″ ″× ″″× ″ ″ ″× ″″× ″ ″ ″× ″ ″″× ″″ ″× ″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″× ″″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″× ″ ″″ ″× ″″ ″× ″″× ″″ ″ ″ ″× ″″ ″× ″″ ″× ″ ″ ″″ ″″ ″× ″ ″ ″× ″ ″ ″× ″ ″× ″ ″× ″″ ″× ″ ″× ″″ ″ ″ ″× ″ ″× ″ ″× ″ ″″ ″× ″″ ″× ″ ″× ″ ″″″ ″× ″ ″× ″ ″× ″ ″ ″ ″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″″ ″ ″× ″ ″× ″ ″× ″ ″″ ″× ″″× ″ ″× ″ ″× ″″× ″ ″× ″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″″ ″ ″× ″″× ″ ″× ″ ″ ″× ″ ″ –″× ″ ″ ″× ″ ″ ″× ″″× ″ ″ ″ ″ ″× ″″× ″″× ″ ″ ″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ″″ ″× ″ ″× ″ ″× ″ ∅ ∅ ∅ ∅ ∅∅ ∅∅ ∅∅ ∅∅ ∅∅ ∅∅ R E V I S I O N BYMARKDATE SHEET OF 6 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 21-18 S.M. O.M.Sep. 15, 21 FR-1 MO O N R E S I D E N C E RE S I D E N T I A L R E M O D E L PR O J E C T A D D R E S S : 47 3 1 2 A B D E L C I R C L E PA L M D E S E R T C A 9 2 2 6 0 P. O . B O X 2 3 0 5 NO R W A L K , C A 9 0 6 5 1 EL E V A T E D D E S I G N & CO N S U L T I N G 9/5/21 FM C 90183 EXP. 9/30/21 R ERET ISGE P OISSFEORN E A RE E N I G N C LIVI C S ETA T FO A INROFILA L FAB I A N MEN D O Z A D Copyright 2020. All rights reserved. The use of these plans, calculations and specifications shall be restricted to the original site for which they were prepared, and publication thereof is expressly limited to such use. Reproduction, publication or reuse by any method, in whole or part, is prohibited without the permission and consent of Elevated Design & Consulting. Title to the Plans, calculations and specifications shall constitute prima facie evidence of the acceptance of these restrictions. In the event of unauthorized reuse of the plans by a third party, the third party shall hold Elevated Design & Consulting. Note: Plans are not valid for construction unless approved by the corresponding municipal governing body. S1.1 2 STRUCTURAL NOTES ∅ ∅ ∅ ∅ ∅∅ ∅∅ ∅∅ ∅∅ ∅∅ ∅∅ Copyright 2018. All rights reserved. The use of these plans, calculations and specifications shall be restricted to the original site for which they were prepared, and publication thereof is expressly limited to such use. Reproduction, publication or reuse by any method, in whole or part, is prohibited without the permission and consent of Elevated Design & Consulting. Title to the Plans, calculations and specifications shall constitute prima facie evidence of the acceptance of these restrictions. In the event of unauthorized reuse of the plans by a third party, the third party shall hold Elevated Design & Consulting. Note: Plans are not valid for construction unless approved by the corresponding municipal governing body. R E V I S I O N BYMARKDATE SHEET OF 6 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 21-18 S.M. O.M.Sep. 15, 21 FR-1 MO O N R E S I D E N C E RE S I D E N T I A L R E M O D E L PR O J E C T A D D R E S S : 47 3 1 2 A B D E L C I R C L E PA L M D E S E R T C A 9 2 2 6 0 P. O . B O X 2 3 0 5 NO R W A L K , C A 9 0 6 5 1 EL E V A T E D D E S I G N & CO N S U L T I N G 9/5/21 FM C 90183 EXP. 9/30/21 R ERET ISGE P OISSFEORN E A RE E N I G N C LIVI C S ETA T FO A INROFILA L FAB I A N MEN D O Z A D S2.0 3 FOUNDATION PLAN ∅ ∅ ∅ ∅ ∅∅ ∅∅ ∅∅ ∅∅ ∅∅ ∅∅ Copyright 2018. All rights reserved. The use of these plans, calculations and specifications shall be restricted to the original site for which they were prepared, and publication thereof is expressly limited to such use. Reproduction, publication or reuse by any method, in whole or part, is prohibited without the permission and consent of Elevated Design & Consulting. Title to the Plans, calculations and specifications shall constitute prima facie evidence of the acceptance of these restrictions. In the event of unauthorized reuse of the plans by a third party, the third party shall hold Elevated Design & Consulting. Note: Plans are not valid for construction unless approved by the corresponding municipal governing body. R E V I S I O N BYMARKDATE SHEET OF 6 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 21-18 S.M. O.M.Sep. 15, 21 FR-1 MO O N R E S I D E N C E RE S I D E N T I A L R E M O D E L PR O J E C T A D D R E S S : 47 3 1 2 A B D E L C I R C L E PA L M D E S E R T C A 9 2 2 6 0 P. O . B O X 2 3 0 5 NO R W A L K , C A 9 0 6 5 1 EL E V A T E D D E S I G N & CO N S U L T I N G 9/5/21 FM C 90183 EXP. 9/30/21 R ERET ISGE P OISSFEORN E A RE E N I G N C LIVI C S ETA T FO A INROFILA L FAB I A N MEN D O Z A D ROOF FRAMING PLAN S2.1 4 ₽"x2½"x2½"₽"x2½"x2½" ₽"x2½"x2½"₽"x2½"x2½" ¾ ¾ ¾ Copyright 2020. All rights reserved. The use of these plans, calculations and specifications shall be restricted to the original site for which they were prepared, and publication thereof is expressly limited to such use. Reproduction, publication or reuse by any method, in whole or part, is prohibited without the permission and consent of Elevated Design & Consulting. Title to the Plans, calculations and specifications shall constitute prima facie evidence of the acceptance of these restrictions. In the event of unauthorized reuse of the plans by a third party, the third party shall hold Elevated Design & Consulting. Note: Plans are not valid for construction unless approved by the corresponding municipal governing body. R E V I S I O N BYMARKDATE SHEET OF 6 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 21-18 S.M. O.M.Sep. 15, 21 FR-1 MO O N R E S I D E N C E RE S I D E N T I A L R E M O D E L PR O J E C T A D D R E S S : 47 3 1 2 A B D E L C I R C L E PA L M D E S E R T C A 9 2 2 6 0 P. O . B O X 2 3 0 5 NO R W A L K , C A 9 0 6 5 1 EL E V A T E D D E S I G N & CO N S U L T I N G 9/5/21 FM C 90183 EXP. 9/30/21 R ERET ISGE P OISSFEORN E A RE E N I G N C LIVI C S ETA T FO A INROFILA L FAB I A N MEN D O Z A D S3.0 5 STRUCTURAL DETAILS ₽ ₽ ⅊ ⅊ ⅊ ⅊ Copyright 2020. All rights reserved. The use of these plans, calculations and specifications shall be restricted to the original site for which they were prepared, and publication thereof is expressly limited to such use. Reproduction, publication or reuse by any method, in whole or part, is prohibited without the permission and consent of Elevated Design & Consulting. Title to the Plans, calculations and specifications shall constitute prima facie evidence of the acceptance of these restrictions. In the event of unauthorized reuse of the plans by a third party, the third party shall hold Elevated Design & Consulting. Note: Plans are not valid for construction unless approved by the corresponding municipal governing body. R E V I S I O N BYMARKDATE SHEET OF 6 TITLE CHECK AND VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH THE WORK. REPORT DISCREPANCIES TO THE ENGINEER. ALL CONSTRUCTION SHALL CONFORM TO THE C.B.C. JOB #:DRAWN: DATE:CHECKED: 21-18 S.M. O.M.Sep. 15, 21 FR-1 MO O N R E S I D E N C E RE S I D E N T I A L R E M O D E L PR O J E C T A D D R E S S : 47 3 1 2 A B D E L C I R C L E PA L M D E S E R T C A 9 2 2 6 0 P. O . B O X 2 3 0 5 NO R W A L K , C A 9 0 6 5 1 EL E V A T E D D E S I G N & CO N S U L T I N G 9/5/21 FM C 90183 EXP. 9/30/21 R ERET ISGE P OISSFEORN E A RE E N I G N C LIVI C S ETA T FO A INROFILA L FAB I A N MEN D O Z A D S3.1 6 STRUCTURAL DETAILS