Loading...
HomeMy WebLinkAboutELEC23-0024 SITE PLAN-SPECS.pdfM}r We Nam nPlan �, When roe tired Men Parcel#: 771-480-008 Address : 624 Arroyo View City, State, ZIP: Palm Desert. Ca, 92260 Purpose of site plan: Generator Scale:1"=30' Owner: SIMON, JULIE & SIMON, CHASADE Legal Information:.58 ACRES IN LOT 16 MB 2881096 TR 25296-3 Land Use Cat: RESIDENTIAL (4 CD -v a c-7w s v 9 (a) Ilalealmmeriesel 15) CA p3 0 �r- 0_ c►?1 a tub -9 M>I Q'i (t4) 1 r CD in 7c CA 0 0 CAUTION 2nd POWER SOURCE STANDBY GENERATOR CONNECTED TO THIS EQUIPMENT 6 " ZPrgLoyo VIE 7-441-t-M -. ,8-aA Ci Z, Z. 4,0 If Protector® Series INCLUDES: • GENERAC® PROTECTOR° SERIES Standby Generators Liquid -Cooled Gaseous Engine 1of9 Two -Line LCD Multilingual Digital Evolution`M Controller (English/Spanish/French/Portuguese) With External Viewing Window for Easy Indication of Generator Status and Breaker Position • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1 % Voltage Regulation • Field Convertible Fuel Type With No Mechanical Adjustment Required. • 5 Year Limited Warranty • UL 2200 Listed • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a structure* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes, https://assets. sw ri,org/I i b rary/Directory0f Listed Products/ Constructionlndustry/973_DoC_204_13204-01-01 _Rev9.pdf FEATURES Standby Power Rating Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz Model RG080 (Aluminum - Bisque) - 80 kW 60Hz al 'AvsmbkaWk, �uc � m..Wei.i.a parova Meets EPA Emission Regulations CA / MA Emission Compliant O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But It doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable GSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINK® CONNECTIVITY: Free with select Protector Series standby generator sets, Mobile Link Wi-Fi allows users to monitor the generator set status from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERAC® O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES, Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. 48/60/80kW GENERAC* application & engineering data GENERATOR SPECIFICATIONS 48 kW 60 / 80 kW Type Synchronous Synchronous Rotor Insulation Class F H Stator Insulation Class N H Telephone Interference Factor (TIF) <50 <50 Alternator Output Leads 1-Phase 4 wire 4 wire Alternator Output Leads 3-Phase 6 wire 6 wire Bearings Sealed Ball Sealed Ball Coupling Flexible Disc Flexible Disc Excitation System Direct Brushless VOLTAGE REGULATION Type Sensing Electronic Single Phase Regulation ± 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady Slate Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 35 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 27F (48kW), 725CCA System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES Aluminum weather protective enclosure Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Enclosed critical grade muf- fler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation, SAE Sound attenuated enclosure ensures quiet operation. (All ratings in accordance with BS5514, IS03046, IS08528, SAE J1349 and DIN6271) ENGINE SPECIFICATIONS 48 kW 60 / 80 kW Make Generac Generac Model Inline 4 cylinder Inline 4 cylinder Cylinders 4 4 Displacement (Liters) 4.5 4.5 Bore (in/mm) 4.5/114.3 4.5/114.3 Stroke (in/mm) 4.25 / 107.95 4.25 /107.95 Compression Ratio 9.9:1 8.851 Intake Air System Naturally Aspirated Turbocharged and aftercooled Lifter Type Hydraulic Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Oil Filter Type Gear Full Flow Spin-0n Cartridge Crankcase Capacity (qt / I) ENGINE COOLING SYSTEM Type Ethylene Glycol 50 / 50 Mix Water Pump Belt -Driven Fan Speed (rpm) 2,100 Fan Diameter 48 kW (in / cm) 20 (50.8) Fan Diameter 60 kW and 80 kW (in / cm) 22 (55.9) Fan Mode Pusher FUEL SYSTEM Fuel Type Natural Gas, Propane Vapor Fuel Shut Off Solenoid Standard LP Fuel Pressure 7 -14 in Water Column NG Fuel Pressure 3.5 -14 in Water Column 48/60/80kW GENERAC' operating data GENERATOR OUTPUT VOLTAGE/kW - 60 Hz kW LPG Amp LPG kW Nat. Gas RG048 120/240 V,10,1.0 pf 48 200 48 200 200 120/208 V, 30, 0.8 pf 48 167 48 167 175 120/240 V,30,0.8 pf 48 144 48 144 150 277/480 V, 30, 0.8 pf 48 72 48 72 80 RG060 120/240 V,10,1.0 of 60 250 60 250 300 120/208 V,30,0.8 p1 60 208 60 208 200 120/240 V, 30, 0.8 pf 60 180 60 180 200 277/480 V, 30, 0.8 pf 60 90 60 90 100 RGO80 120/240 V,10,1.0 pf 75 312 80 333 400 120/208 V, 30, 0.8 pf 75 260 80 278 300 120/240 V, 30, 0.8 pf 75 226 80 241 300 277/480 V, 30, 0.8 pf 75 113 80 120 150 SURGE CAPACITY IN AMPS Voltage Dip @ < .4 pf 15% 30% RG048 120/240 V, 10 100 300 120 / 208 V, 30 118 242 120 / 240 V, 30 144 260 277 / 480 V, 30 64 123 RG060 120 / 240 V, 10 150 413 120 / 208 V, 30 135 313 120 / 240 V, 30 117 289 277 / 480 V, 30 54 122 RG080 120/240 V, 10 283 600 120/208 V, 30 236 500 120 / 240 V, 30 204 432 277 / 480 V, 30 102 192 Note: Fuel pipe must be sized for full load. For Btu content, multiply ft3/ hr x 2,520 (LP) or ft3/ hr x 1,000 (NG). For megajoule content, multiply m3 / hrx 93.15 (LP) or m3 / hr x 37.26 (NG). Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. ENGINE FUEL CONSUMPTION Natural Gas Propane (ft3/ hr) (m3/hr) (gal/hr) (93/hr) (I/hr RG046 Exercise cycle 101 2.86 0.67 24.5 2.54 25% of rated load 201 5.7 2.88 104.7 10.9 50% of rated load 336 9.5 4,16 151.3 15.7 75% of rated load 447 12.7 5.28 192 20 100% of rated load 604 17.1 6.61 240.4 25 RG060 Exercise cycle 103 2.9 0.9 33.2 3.5 25% of rated load 257 7.3 2.1 78 8.1 50% of rated load 432 12.2 4.4 161.2 16.8 75% of rated load 618 17.5 6.8 247.2 25.7 100% of rated load 808 22.9 8.4 305.6 31.8 RG080 Exercise cycle 103 2.9 0.9 33.2 3.5 25% of rated load 292 8.3 2.6 93.6 9.7 50% of rated load 534 15.1 5.7 '208.8 21.7 75% of rated load 799 22.6 8,3 303.2 31.5 100% of rated load 1,063 30.1 10.8 393,2 40.9 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. y a) CD 4 of 9 48/60/80kW ENGINE COOLING 48 kW GENERAC' operating data Air Flow (inlet air including alternator and combustion air in cfm / cmm) 2,829 / 80.1 3,197 / 90.5 System Coolant Capacity (gal / liters) 2.9 / 11 4.5 / 17 Heat Rejection to Coolant (BTU per hr/ MJ per hr) 201,600 204,570 Maximum Operation Air Temperature on Radiator (°F/°C) 150 / 66 150/66 Maximum Ambient Temperature (°F / °C). 140 / 60 140 / 60 COMBUSTION REQUIREMENT Flow at Rated Power (scfm / cmm) 92.7 / 2.6 170.4 / 4.8 SOUND EMISSIONS Sound Output in dB(A) at 23 ft (7 m) With Generator* 68 68 "In exercise mode EXHAUST Exhaust Flow at Rated Output (scfm / cmm) 104 / 2.9 81 / 5. Exhaust Temperature at Muffler Outlet (°F / °C) 945 / 507 1,213 / 656 ENGINE PARAMETERS Rated Synchronous rpm 1,800 j 1,800 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (48 kW) .. 1% for every 100 m above 183 m or 3% for every 1,000 ft above 600 ft Altitude Deration (60 kW and 80 kW) 1% for every 100 m above 915 m or 3% for every 1,000 ft above 3,000 ft CONTROLLER FEATURES Two -Line Plain Text LCD Display.. Simple user interface for ease of operation. Mode Switch: Auto Automatic Start on Utility failure. 7 day exerciser. Off Stops unit. Power is removed. Control and charger still operate. Manual.. Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable Start Delay Between 10-30 Seconds . 10 sec standard Engine Start Sequence............................................................................................. .. Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up 5 sec Engine Cool -Down 1 min Starter Lock -Out. .......... ..... ..... .... .................... ....,. ...... ........... .................................... ........... ........... ..........Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Automatic Voltage Regulation With Over and Under Voltage Protection Standard Automatic Low Oil Pressure Shutdown Standard Overspeed Shutdown Standard, 72 Hz High Temperature Shutdown Standard Overcrank Protection Standard Safety Fused Standard Failure to Transfer Protection Standard Low Battery Protection Standard 50 Event Run Log Standard Future Set Capable Exerciser Standard Incorrect Wiring Protection Standard Internal Fault Protection Standard Common External Fault Capability Standard Governor Failure Protection Standard GENERAC' 48 / 60 / 80 kW G0071690 G006478-0 G007992-0 G007990-0 G005651-0 Base Plug Kit G005703-0 - Bisque Paint Kit G007991-0 G006664-0 G006665-0 G007993-0 G007005-0 Wireless Remote Extension Harness E-Stop Wi-Fi LP Fuel Level Monitor G007000-0. (50 amp) Smart Management G007006-0(100 amp) Module A0000018981 A0000019001 Ultrasonic Cleaner Solution All Surface Protectant Mobile Link®4G LTE Cellular Accessory available accessories Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device, You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. Kit, Adapter Mobile Link The Harness Adapter Kit is required to make liquid -cooled units compatible with Mobile L/C (Required for QT and Link°. RG Series) If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain Cold Weather Kit optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. Extreme Cold Weather Kit Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only. Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. Scheduled Maintenance The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform Kit complete maintenance on Generac liquid -cooled generators. Local Wireless Monitor Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever leaving the house. Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater. E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergen- cy. The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. !Smart Management Modules (SMM) are used to optimize the performance of a standby' generator. They manage large electrical loads upon startup and shed them to aid in ;recovery when overloaded. In many cases, using SMM's can reduce the overall size and; f cost of the system. `An ultra -concentrated anti -corrosive cleaning solution engineered to reach the smallest `cavities to clean the toughest contaminants. This water based formula is non -toxic, biodegradable, safe for both metal and plastic surfaces, and is superior in rinsability. All surface protectantforvinyl, rubber, plastics creates a barrier that seals & protects surf !faces from water, UV rays while renewing the look of the surface. 0D co 0 0 0 5 of 9 48 kW Drawing #A0000293718-C (1 of 2) 0 �ooy:Q000 _ ' L.rw` w u r °o _ L w S o w w w SERVICE ITEM OIL FILL CAP OIL DIP STICK OIL FILTER OIL DRAIN HOSE RADIATOR DRAIN HOSE COOLANT RECOVERY BOTTLE RADIATOR FILL CAP AIR CLEANER ELEMENT SPARK PLUGS MUFFLER DRIVE BELT BATTERY .77 5 GENERAC' installation layout DIMENSIONS: MM [INCH] 48 kW Drawing #A0000293718-C (2 of 2) Z z w w 0 z 00 F W 0 Z <00 (99Zw 00 ~(0 aZ0 <0< dW D0 0 • < ?(0>z 0o , a (0 0 w wp J0 <0 >0 co w= �Ci) m alN f o • o REAR VIEW LEFT SIDE VIEW GENERAC' installation layout DIMENSIONS: MM [INCH] 7af9 GENERAL" 60 / 80 kW Drawing #A0000293264 (1 of 2) up installation layout so r^+ F 60 / 80 kW Drawing #A0000293264 (2 of 2) GENERAC° GENERAC' installation layout Generac Power Systems, Inc. • S45 W29290 HWY, 59, Waukesha, WI 53189 • generac.com ©2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part Number A0000373704 Rev E 9/25/2020