Loading...
HomeMy WebLinkAboutRCVR21-0010 APPROVED PLANGSPublisherVersion 0.78.100.100 SCALE = AS NOTED Sheet 1/25/2021 DATE = 1/25/2021 PROJECT 2101 CONTACT= STAFF PROJECT INFORMATION/ SITE PLAN T 1.1 INSTRUMENTS OF SERVICE THESE DRAWINGS ARE AN INSTRUMENT OF SERVICE AND REMAIN THE PROPERTY OF UNITED BUILDERS DESIGN. THEY ARE NOT TO BE REPRODUCED OR ALTERED IN ANY WAY, NOR DISCLOSED OR ASSIGNED TO ANY THIRD PARTY WITHOUT THE EXPRESS WRITTEN PERMISSION OF UNITED BUILDERS DESIGN. UNITED BUILDERS D E S I G N 74 2 8 0 AS T E R DR PA L M DE S E R T , CA 92 2 6 0 LO P E Z PA T I O RE P L A C E M E N T 1st CITY SUBMITTAL2021-01-25 RAMON ANGUIANO UNITEDBUILDERS21@GMAIL.COM PHONE:760-797-5972 100 sq ft 44'-10" +/- 8' - 0 " 55'-11" 14 ' - 0 " 4'-0"13 ' - 3 " LOT 13 TRACT MAP NO. XXXXX APPROVED PAD = 100.0 FINISH FLOOR = 100.5 293 sq ft 1,384 sq ft (E) 359 sq ft REPLACE EXISTING HARDSCAPE NEW HARDSCAPEEXISTING COVER PATIO 44'-10" X 8'-0" PROPOSED COVER PATIO 55'-11" X 14'-0" ADDITION 424 SF. G. A S T E R D R I V E BEDROOM 1 BEDROOM 2 WC 2 WC 1 CL BEDROOM 3 KITCHENDINING CHILDRENS PLAYROOM STORAGE LIVING RM. GRASS GRASS GRASSGRASS GRASS EXISTING RESIDENCE CARTPORT DRIVEWAY SHED N WATER / SEWER: C.V.W.D. P.O. BOX 1058 COACHELLA, CA (760) 398-2651 CATV: SPECTRUM 41725 COOK ST. PALM DESERT, CA (760) 340-2225 TELEPHONE: VERIZON 82901 BLISS AVE. INDIO, CA 1-800-483-5000 GAS: SO. CAL. GAS CO. 211 N. SUNRISE WAY PALM SPRINGS, CA 1-800-427-2200 ELECTRICAL: SOUTHERN CALIFORNIA EDISON P.O. BOX 600 ROSEMEAD, CA (760) 324-8500 GENERAL CONTRACTOR: TBD SCOPE OF WORK REMOVE EXISTING PATIO/ HARDCAPE AND REPLACE WITH NEW PATIO AND HARDSCAPE. VICINITY MAP LOT 13 74280 ASTER DR LOPEZ PATIO REPLACEMENT 74280 ASTER DR LOT 13 SHEET INDEX T 1.1 PROJECT INFORMATION & SITE PLAN CONSTRUCTION INFO. CONSTRUCTION HOURS: OCTOBER 1 THRU APRIL 30 MONDAY - FRIDAY 7 AM - 5:30 PM SATURDAY 8 AM - 5:00 PM SUNDAY NOT ALLOWED GOV. HOLIDAYS NOT ALLOWED MAY 1 THRU SEPTEMBER 30 MONDAY - FRIDAY 6 AM - 7:00 PM SATURDAY 8 AM - 5:00 PM SUNDAY NOT ALLOWED GOV. HOLIDAYS NOT ALLOWED FAILURE TO ABIDE BY THESE WORK HOURS IS AN INFRACTION OF THE INDIAN WELLS MUNICIPAL CODE 9.24.070 1 All contractors shall submit Certificate of workmen’s compensation insurance coverage prior to the issuance of a Building Permit per California Labor Code, Section 3700. 2 All construction shall comply with the following codes including all local codes and ordinances whether or not specifically shown in these drawings and specifications. 2019 California Residential Code 2019 California Mechanical Code 2019 California Plumbing Code 2019 California Electrical Code 2019 California Energy Code 2019 California Fire Code 2019 California Green Buildings Standards Code 3 Contractors are responsible for all work regardless of the location of the information of the documents. 4 Contractor shall confirm that proper finish grade elevations have been provided at the perimeter of the building areas, refer to building and adjoining areas, refer to building plans. Report any discrepancies to the designer prior to proceeding with rough grading. 5 Provide pipe guards at all above ground utility Equipment as dictated by governing agencies. 6 All construction shall be completed in a craftsman like manner. 7 The general contractor shall be responsible for verifying all dimensions and existing conditions thereon before commencing work. report any discrepancies and/or potential problems to the architect prior to proceeding with affected work. 8 general contractor shall coordinate all underground items with the plumbing, electrical, gas, telephone, and cable tv drawings. 9 All sub-contractors shall familiarize themselves with the plans and specifications as well as current site conditions. Any discrepancies shall be brought to the attention of the Designer. 10 See also specifications for materials and standards. 11 The general contractor is solely responsible for Coordination among his various subcontractors. 12 Any changes required to be made to these plans or specifications shall be brought to the attention of the Designer. Any changes made without the written consent of the Designer shall not be the responsibility of the Designer. 13 Drawings and specifications are property of the Designer and are copyrighted for her use unless authorization is given to the Owner in writing. 14 All contractors shall have a current valid city of Palm Desert business license prior to permit 15 General contractor shall notify all applicable local Governing, authorities and utilities prior to covering Up any work requiring inspection. 16 Storage of building materials or debris shall be confined to the lot for which the permit is issued. Adjacent vacant properties may not be utilized for this purpose unless written permission of the owner is on file with this office. The public right-of-way shall be maintained in a clear condition at all times. PDMC, Chapter 8.02. 17 All 'or equal' substitutions must be submitted to, and approved by the Building Official prior to installation of the item. 2019 CRC R106.1.1 18 All exterior wall openings, flashing, counter flashing, expansion joints, shall be constructed in such a manner to make them waterproof; caulk and flash where necessary for a complete and workable installation. 19 The builder shall provide the bldg owner manager and original occupants with a list of the feature, materials,components and mechanical devices installed in the building; instructions on how to use them efficiently and, maintenance for efficient operation note on the plans title 24 . section 10-103(b) 20 Prior to requesting a Foundation Inspection, the Owner's Engineer shall field verify the building pad height and top of form height, as complying with the approved grading plan per Palm Desert Municipal Code, Chapter 27-12 190. 21 Use approved flashing materials at all exterior openings, Unless noted otherwise, all sheet metal shall be 24 gauge g.i. or better, painted with g.i. vinyl wash primer and a zinc dust primer, excepting pre-finished metal as approved by The designer. 22 The City Building Inspector has the authority to request fully revised plan sheets with all field changes clouded with deltas to be submitted for City plan review when he/she determines the number of field revisions warrant such a request. OWNER INFO FERNANDO LOPEZ 74280 ASTER DR PALM DESERT CA, 92260 PROJECT INFO. ZONING R1 LOT LOT 13 TRACT T5SR6E APN 624-220-009 TYPE OF CONSTRUCTION TYPE V-B AREA TABULATIONS MAIN LIVING AREA 1,384 SF. TOTAL 1,384 SF FRONT PATIO 293 SF. CARPORT 359 SF. SHED 100 SF. COVER AREAS TOTAL 752 SF. TOTAL LOT AREA 10,018 SF. BUILDING COVERAGE 21.0% OR 2,136 SF.