HomeMy WebLinkAboutPLAN.pdfH o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 He n d l e r R e s i d e n c e 21003 13 A v e n i d a A n d r a Pa l m D e s e r t , C A 9 2 2 6 0 1/13/2021 SF MJR Sheet Michael Rango PV-0.0 CO V E R S H E E T DESCRIPTION OF WORK: ROOF MOUNTED PHOTOVOLTAIC (SOLAR ELECTRIC) INSTALLATION TILT MOUNTED @ 5° FACING AN AZIMUTH OF 157°, 202°, AND 247° CONSISTING OF (56) REC 380 WATT MODULES (21.28Kw) AND A TESLA BATTERY BACKUP SYSTEM. RACK MOUNTING SYSTEM IS UNIRAC SOLARMOUNT ALUMINUM SUPPORT RAILS AND FAST JACK SOLAR STANCHIONS. INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES: CEC 2019 - ARTICLE 690, 705,706 AND OTHERS NEC 2020 705.13 CPC 2019 CBC 2019 CMC 2019 CFC 2019 DRAWING SHEETS: COVER SHEET PV-0.0 OPTIMIZER STRINGING NOTES (NOT FOR PERMITTING)PV-0.0 (2) SITE PLAN PV-1.0 SYSTEM PERFORMANCE NOTES (NOT FOR PERMITTING)PV-1.0 (2) ROOF PLAN PV-2.0 SINGLE LINE DIAGRAM PV-3.0 MOUNTING DETAIL PV-4.0 WARNING LABELING PV-5.0 SPECIFICATION SHEETS: MODULE AND INVERTERS TESLA POWERWALL2 TESLA GATEWAY - UL1741 PCS UNIRAC CERTIFICATION NTS GENERAL NOTES: 1.ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDER THE DIRECT SUPERVISION OF A LICENSED ELECTRICIAN. 2.ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741SA CERTIFIED AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVED FOR IT'S PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. 3.THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAIC SYSTEM WHEN THE UTILITY GRID IS NOT IN OPERATION. 4.PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCAL AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. 5.THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ON THE ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE PHOTOVOLTAIC SYSTEM OR INSTALLATION. 6.ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS. 7.ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS. 8.TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTURE Palm Desert Municipal Code Requirements: (required on first page) Basic Wind Speed: (3 second gust) •Risk Category IV - 108 mph (Palm Desert use Category IV) CONSTRUCTION HOURS: OCTOBER 1 THRU APRIL 30 MAY 1 THRU SEPTEMBER 30 Monday - Friday 7:00 a.m. - 5:30 p.m. Monday - Friday 5:30 a.m. - 7:00 p.m. Saturday 8:00 a.m. - 5:00 p.m. Saturday 8:00 a.m. - 5:00 p.m. Sunday NOT ALLOWED Sunday NOT ALLOWED Government Code Holidays-- NOT ALLOWED A violation of the above work hours is a citable offense under Palm Desert Municipal Code Section 9.24.070. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 OPTIMIZER / STRINGING (INSTALLATION NOTES NOT FOR PERMITTING) Panel S/N: A V E N I D A A N D R A H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 He n d l e r R e s i d e n c e 21003 13 A v e n i d a A n d r a Pa l m D e s e r t , C A 9 2 2 6 0 1/13/2021 SF MJR Sheet Michael Rango PV-1.0 SI T E P L A N 1" = 20' SITE PLAN KEYNOTE: EXISTING ELECTRICAL 1.1 400A MAIN ELECTRICAL PANEL 1.2 SUBPANEL NEW ELECTRICAL (ADJACENT TO MSP) 2.1 SYSTEM AC DISCONNECT 2.2 ESS SAFETY DISCONNECT NEW ELECTRICAL (INSIDE GARAGE) 2.3 TESLA GATEWAY/GENERATION PANEL 2.4 BATTERY COMBINER PANEL 2.5 TESLA POWERWALL (x3) 2.6 SE7600H-US PV INVERTER SE11400H-US PV INVERTER SITE LEGEND FIRE EASEMENT/ACCESS EAVE SETBACK/WALL SYSTEM PERFORMANCE (INSTALLATION NOTES NOT FOR PERMITTING) CREW NOTES: INVERTER M/N INVERTER S/N STRING CONFIG (1 column each MPPT) INPUT #1 2 AZIMUTH/ ORIENTATION SLOPE/TILT VOC @ Jbox VOC @ Inverter V+ to Gnd V- to Gnd AC L1-L2 AC L1-N AC L2-N AC POWER WATTS @ TIME OF DAY AMBIENT TEMP. WEATHER SUNNY PARTLY CLOUDY CLOUDY INVERTER M/N INVERTER S/N STRING CONFIG (1 column each MPPT) INPUT #1 2 AZIMUTH/ ORIENTATION SLOPE/TILT VOC @ Jbox VOC @ Inverter V+ to Gnd V- to Gnd AC L1-L2 AC L1-N AC L2-N AC POWER WATTS @ TIME OF DAY AMBIENT TEMP. WEATHER SUNNY PARTLY CLOUDY CLOUDY INVERTER M/N INVERTER S/N STRING CONFIG (1 column each MPPT) INPUT #1 2 AZIMUTH/ ORIENTATION SLOPE/TILT VOC @ Jbox VOC @ Inverter V+ to Gnd V- to Gnd AC L1-L2 AC L1-N AC L2-N AC POWER WATTS @ TIME OF DAY AMBIENT TEMP. WEATHER SUNNY PARTLY CLOUDY CLOUDY STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 He n d l e r R e s i d e n c e 21003 13 A v e n i d a A n d r a Pa l m D e s e r t , C A 9 2 2 6 0 1/13/2021 SF MJR Sheet Michael Rango PV-2.0 RO O F P L A N 1" = 5' 1.VERIFY RAFTER SPACING IN THE FIELD BEFORE ATTACHING MOUNTS ROOF. 2.ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF RAFTERS AND MAKE STRUCTURAL CONNECTION TO THE RAFTERS. 3.STRUCTURAL CONNECTION TO ENGINEERED TRUSS SHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAG SCREWS 3" MIN. EMBEDMENT. 4.ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS. 5.PHOTOVOLTAIC MODULES SHALL HAVE 1.8 MOUNTS (LAG SCREWS) PER PANEL. 6.(E) ROOF STRUCTURE IS FLAT 2X10 ENGINEERED TRUSS/JOIST 16" O.C TYP. 7.(E) ROOFING MATERIAL IS 1 LAYER OF FOAM OVER 1 LAYER OF 30LB. FELT PAPER AND 1/2" OSB PLYWOOD DECKING. 8.MODULE DIMENSIONS 67.7" x 40" MOUNT PLAN KEYNOTE: RACK MOUNT COMPONENTS 1.1 UNIRAC ALUMINUM SUPPORT RAIL 1.2 FAST JACK SOLAR STANCHIONS STRUCTURAL 2.1 ROOF SUPPORTS 2x10 ENGINEERED TRUSS/JOIST (16" O.C.) 48" SPACING BETWEEN MOUNTS IS TYPICAL - MAX SPAN 6' C AC OUT AC OUT PV DC IN D BA J-BOX THE MAIN BREAKER IN THE BATTERY COMBINER SWERVES AS A MEANS OF DISCONNECT IN-LINE OF -SITE FOR THE BATTERIES AC OUT (N) BATTERY COMBINER PANEL 125A BUSS, 120/240V, 1PH, 3W AC OUTAC OUT 30A 30A TESLA POWERWALL 2 USABLE ENERGY 13.5kwh MAX OUTPUT 5kW POWER FACTOR +/- 0.85 240V/24A TESLA POWERWALL 2 USABLE ENERGY 13.5kwh MAX OUTPUT 5kW POWER FACTOR +/- 0.85 240V/24A TESLA POWERWALL 2 USABLE ENERGY 13.5kwh MAX OUTPUT 5kW POWER FACTOR +/- 0.85 240V/24A E E E 30A 90A BREAKER ESS METER NO LOADS ALLOWED IN THIS PANEL 2 SOLAREDGE POWER OPTIMIZER P400 RATED DC INPUT POWER - 400 WATTS MAXIMUM INPUT VOLTAGE - 80 VDC MPPT RANGE - 8 TO 80 VDC MAXIMUM INPUT CURRENT - 12.5 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5250 WATTS STC PER STRING MAXIMUM NOTE: Tesla battery does not export, loads in the BU/critical loads panel self-consume battery current. Tesla gateway as a PCS (power control system) limits the backfeed to the rated output of the photovoltaic interactive inverter rated output [79.5A].The 200A POC breaker is sized for existing loads in the BU/critical loads panel. Only photovoltaic current is considered in the POC calculations, where the output of the PCS shall be used to calculate conductor and over current protection to protect overloading buss bars in distribution equipment. While the 2020 NEC has formally introduced a Power Control System , it allows for backfeed that exceeds the 120% rule. Conductor Export Limit implemented with the Powerwall system is designed to function in compliance with the 120% rule from the 2019 CEC, 2017 NEC, and 2014 NEC. This Conductor Limit feature is beneficial for safely connecting a larger amount of energy storage on a site, without overloading the busbar. (See additional notes related to TESLA UL 1741 PCS and the control of back feed current by the Power Control System) 2 STRINGS OF 11 1 STRING OF 12 F (E) BU LOADS PANEL 200A BUSS, 120/240V, 1PH, 3W G 200A BREAKER ESS METER +- TESLA GATEWAY 2 TPN #1232100-xx x PCS 200A H 200A/240V (N) SYSTEM DISCONNECT ADJACENT TO MSP N.C. N.C. CONTACT (N) ESS DISCONNECT (RAPID SHUT DOWN) ADJACENT TO MSP AUX PORT COM WIRE (CAT 5) H 1 CONTROLLED CONDUCTOR CURRENT [79.5A] 90A 60A 2 GATEWAY 2 INTERNAL PANEL 200A BUSS, 120/240V, 1PH, 3W GENERATION 60A SE11400H-US = 47.5A x 1.25 = 59.4A SE7600H-US = 32.0A x 1.25 = 40.0A TOTAL 79.5A x 1.25 = 99.4A (BREAKER SIZED FOR BU PANEL LOADS) (E) MAIN SERVICE PANEL 400A BUSS, SPLIT 200A 120/240V, 1PH, 3W 200A EXISTING AC GEC 200A MSP NO LOADS IN THIS PANEL H ESS METER PCS CONTROLLED CURRENT SETTING: 79.5A The maximum output current from this system towards the main panel is controlled electronically. Refer to manufacturer's instructions for more information. 1 WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR 2 WARNING: THIS SENSOR IS PART OF A POWER CONTROL SYSTEM. DO NOT REMOVE. REPLACE ONLY WITH SAME TYPE AND RATING. TESLA BATTERY 24A x 3 = 72A x 1.25 = 90A Note: PV current serves to charge the batteries, the Powerwalls only self consume to the BU panel when PV current is unavailable and is limited to the BU load demand not to exceed 72A SE11400H-US = 47.5A x 1.25 = 59.4A SE7600H-US = 32.0A x 1.25 = 40.0A TESLA BATTERY 24A x 3 = 72.0A x 1.25 = 90.0A TOTAL 151.5A x 1.25 = 189.4A NOTES:EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690, 705 , 706 AND OTHERS. 1. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS A PHOTOVOLTAIC DISCONNECT. 2. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING-ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS-TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION" 3. PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2. INVERTER OUTPUT VOLTAGE 4. LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS PER NEC 690-64(b)7. 5. INDIVIDUAL INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE. 6.ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE. 7.ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBLE TO ANYONE OTHER THAN QUALIFIED PERSONS. 8.ALL PV SYSTEM EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY. 9.ALL EXTERIOR WIRING MATERIAL SHALL BE SUITABLE FOR A SUN EXPOSURE AND WET LOCATIONS. 10.REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR OUTPUT CIRCUIT CONDUCTOR. 11.CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED. 12.ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2019 CALIFORNIA ELECTRIC CODE & NEC 2020 705.13. 13.BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT. PV DC IN J-BOX BA 2 STRINGS OF 11 INTEGRATED GFCI AND 240 VAC, 32 AMPS MAX OUTPUT: 7600 WATTS MAX INPUT: 400 TO 480 VDC GRID-TIE INVERTER SOLAREDGE SE7600H-US OUTPUT EFFICIENCY: 99% DC DISCONNECTS INTEGRATED GFCI AND 240 VAC, 47.5 AMPS MAX OUTPUT: 11400 WATTS MAX INPUT: 400 TO 480 VDC GRID-TIE INVERTER SOLAREDGE SE11400H-US OUTPUT EFFICIENCY: 99% DC DISCONNECTS 21,280 WATT DC (20,042 WATT AC) SOLAR ELECTRIC ARRAY 56 REC 380 WATT MODULES MODEL NO. REC380AA 56 x 361.5 PTC x 99% EFF = 20.042 kW AC INDIVIDUAL MODULE RATING: PTC = 361.5 WATTS Voc = 44.7 VDC Isc = 10.46 AMPS H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 He n d l e r R e s i d e n c e 21003 13 A v e n i d a A n d r a Pa l m D e s e r t , C A 9 2 2 6 0 1/13/2021 SF MJR Sheet Michael Rango PV-3.0 SI N G L E L I N E D I A G R A M NTS Scale: 1" = 1' 5-7 DEGREE TILT DETAIL1 MOUNT DETAIL KEYNOTE: RACK MOUNT COMPONENTS 1.1 PHOTOVOLTAIC MODULE 1.2 MODULE CLAMP 1.3 UNIRAC "SOLARMOUNT" SUPPORT RAIL 1.4 SS RAIL T-BOLT AND NUT 1.5 UNIRAC L-FOOT 1.6 ADJUSTABLE ALL TREAD 1.7 FAST JACK SOLAR STANCHION (4.5" - 7" typical) 1.8 3.5" SS LAG SCREWS (3" minimum embedment ) STRUCTURAL 2.1 FOAM ROOF 2.2 30LB FELT PAPER 2.3 1/2" OSB ROOF DECKING 2.4 2 x 10 ENGINEERED TRUSS (RAFTER) 16" O.C. TYP.H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 He n d l e r R e s i d e n c e 21003 13 A v e n i d a A n d r a Pa l m D e s e r t , C A 9 2 2 6 0 1/13/2021 SF MJR Sheet Michael Rango PV-4.0 AT T A C H M E N T D E T A I L 1" = 1' WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAYBE ENERGIZED IN THE OPEN POSITION DC DISCONNECTS AND J-BOXES CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PLACE ON MSP CONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTING ALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BE INSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. CEC ARTICLES 690.56(B) AND 705.10. FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALL LETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B)(2) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS CEC 690.56(C)(1)(A) Label for PV Systems that shut down the array and the conductors leaving the array. The title “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” shall utilize capitalized characters with a minimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall be capitalized with a minimum height of 4.8 mm (3∕16 in.) in black on white background. PV INVERTER SERVICE PANEL (YOU ARE HERE)SYSTEM AC DISCONNECT ESS AC DISCONNECT GATEWAY/GENERATION PANEL BATTERY COMBINER PANEL BATTERY SUB PANEL HOT PURPLE ENERGY 760.322.4433N 1 2 4 5 7 8 6 3 LEGEND: THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR PANELS ON ROOF CAUTION 13 AVENIDA ANDRA, PALM DESERT, CA 92260 WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE ADJACENT TO BACK FED BREAKER 705.12(B)(1)(3)(b) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PLACE NEXT TO INVERTER AC DISCONNECTS 690.56(C)(3) WARNING: PHOTOVOLTAIC POWER SOURCE CONDUITS AND RACEWAYS EVERY 10' 690.31(G)(3) PLACE ON BU/CRITICAL LOADS PANEL BACK UP CRITICAL LOADS PANEL BATTERY BACKUP CONNECTED AC DISCONNECT - MAIN BREAKER MAX AC CURRENT : 151.5 A AC VOLTAGE : 240 V GENERATION COMBINER PANEL WARNING - MULTIPLE POWER SOURCES PV AND BATTERY COMBINER PANEL AC DISCONNECT - MAIN BREAKER MAX AC CURRENT : 151.5 A AC VOLTAGE : 240 V PLACE ON GENERATION COMBINER PANEL PLACE ON BATTERY COMBINER PANEL BATTERY COMBIINER PANEL WARNING BATTERY COMBINER PANEL AC DISCONNECT - MAIN BREAKER MAX AC CURRENT : 72 A AC VOLTAGE : 240 V PLACE ON ESS DISCONNECT AT MSP PV SYSTEM AC DISCONNECT WARNING - DUAL POWER SOURCE SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM MAX AC CURRENT : 79.5 A AC VOLTAGE : 240 V PLACE ON SYSTEM DISCONNECTS ESS SAFETY DISCONNECT OPENING THIS SWITCH DISABLES THE BATTERIES AND DE-ENERGIZES ALL CURRENT CARRYING CONDUCTORS AT THE SOURCE WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR PCS CONTROLLED CURRENT SETTING: 79.5A The maximum output current from this system towards the main panel is controlled electronically. Refer to manufacturer's instructions for more information. MAXIMUM VOLTAGE 480 V MAXIMUM CIRCUIT CURRENT 20 A MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED)15A SE7600H-US PLACE ON DC DISCONNECT MAXIMUM VOLTAGE 480 V MAXIMUM CIRCUIT CURRENT 30.5 A MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED)15A SE11400H-US H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 He n d l e r R e s i d e n c e 21003 13 A v e n i d a A n d r a Pa l m D e s e r t , C A 9 2 2 6 0 1/13/2021 SF MJR Sheet Michael Rango PV-5.0 WA R N I N G L A B E L S NTS