HomeMy WebLinkAboutAPPROVED PLANH
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Ra
n
k
i
n
R
e
s
i
d
e
n
c
e
21109
42
6
2
0
A
d
a
l
i
n
W
a
y
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
1
1
5/11/2021
SF
MJR
Sheet
Michael Rango
PV-0.0
CO
V
E
R
S
H
E
E
T
DESCRIPTION OF WORK:
ROOF MOUNTED PHOTOVOLTAIC (SOLAR ELECTRIC) INSTALLATION FLUSH MOUNTED @ 18°
FACING AN AZIMUTH OF 197° CONSISTING OF (17) REC325NP 325 WATT MODULES (5.52Kw).
RACK MOUNTING SYSTEM IS UNIRAC SOLARMOUNT ALUMINUM SUPPORT RAILS AND PEGASUS
TILE REPLACEMENT MOUNTS.
INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES:
CEC 2019 - ARTICLE 690, 705,706 AND OTHERS NEC 2020 705.13
CPC 2019
CBC 2019
CMC 2019
CFC 2019
DRAWING SHEETS:
COVER SHEET PV-0.0
OPTIMIZER STRINGING NOTES (NOT FOR PERMITTING)PV-0.0 (2)
SITE PLAN PV-1.0
SYSTEM PERFORMANCE NOTES (NOT FOR PERMITTING)PV-1.0 (2)
ROOF PLAN PV-2.0
SINGLE LINE DIAGRAM PV-3.0
MOUNTING DETAIL PV-4.0
WARNING LABELING PV-5.0
SPECIFICATION SHEETS:
REC325NP MODULE AND SE6000H-US INVERTER
TESLA POWERWALL2
TESLA GATEWAY - UL1741 PCS
UNIRAC CERTIFICATION
NTS
GENERAL NOTES:
1.ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDER THE
DIRECT SUPERVISION OF A LICENSED ELECTRICIAN.
2.ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741SA CERTIFIED
AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVED FOR IT'S
PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA
STANDARDS.
3.THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING
PROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAIC SYSTEM
WHEN THE UTILITY GRID IS NOT IN OPERATION.
4.PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCAL
AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER.
5.THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEAD
LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ON THE
ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE
PHOTOVOLTAIC SYSTEM OR INSTALLATION.
6.ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS.
7.ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE
WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS.
8.TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTURE
Palm Desert Municipal Code Requirements: (required on first page)
Basic Wind Speed: (3 second gust)
•Risk Category IV - 108 mph (Palm Desert use Category IV)
CONSTRUCTION HOURS:
OCTOBER 1 THRU APRIL 30 MAY 1 THRU SEPTEMBER 30
Monday - Friday 7:00 a.m. - 5:30 p.m. Monday - Friday 5:30 a.m. - 7:00 p.m.
Saturday 8:00 a.m. - 5:00 p.m. Saturday 8:00 a.m. - 5:00 p.m.
Sunday NOT ALLOWED Sunday NOT ALLOWED
Government Code Holidays-- NOT ALLOWED
A violation of the above work hours is a citable offense under Palm Desert Municipal Code Section 9.24.070.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
OPTIMIZER / STRINGING (INSTALLATION NOTES NOT FOR PERMITTING)
Panel S/N:
AD
A
L
I
N
W
A
Y
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Ra
n
k
i
n
R
e
s
i
d
e
n
c
e
21109
42
6
2
0
A
d
a
l
i
n
W
a
y
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
1
1
5/11/2021
SF
MJR
Sheet
Michael Rango
PV-1.0
SI
T
E
P
L
A
N
1" = 15'
For Photovoltaic arrays occupying not more than 33 percent of the plan view
total roof area, not less than 18" clear set back is required on both sides of a
horizontal ridge. For Photovoltaic arrays occupying more than 33 percent of
the plan view total roof area, not less than 36" clear set back is required on
both sides of a horizontal ridge. CRC R324.6.2
Not less than two minimum 36" wide pathways on separate roof planes, from
lowest roof edge to ridge, shall be provided on all buildings. At least one
pathway shall be provided on the street or driveway side of the roof. CRC
R324.6.1
Designation of ridge, hip, and valley does not apply to roofs with 2-in-12 or
less pitch.
Total sq ft = 2,115
Solar sq ft = 309 (14.6%)
SITE PLAN KEYNOTE:
EXISTING ELECTRICAL
1.1 125A MAIN ELECTRICAL PANEL
NEW ELECTRICAL
(INSIDE GARAGE)
2.1 SYSTEM AC DISCONNECT
2.2 SE6000H-US PV INVERTER
SITE LEGEND
FIRE EASEMENT/ACCESS
EAVE SETBACK/WALL
SYSTEM PERFORMANCE (INSTALLATION NOTES NOT FOR PERMITTING)
CREW NOTES:
INVERTER M/N
INVERTER S/N
STRING CONFIG
(1 column each
MPPT)
INPUT #1 2
AZIMUTH/
ORIENTATION
SLOPE/TILT
VOC @ Jbox
VOC @ Inverter
V+ to Gnd
V- to Gnd
AC L1-L2
AC L1-N
AC L2-N
AC POWER
WATTS @
TIME OF DAY
AMBIENT TEMP.
WEATHER SUNNY PARTLY CLOUDY CLOUDY
INVERTER M/N
INVERTER S/N
STRING CONFIG
(1 column each
MPPT)
INPUT #1 2
AZIMUTH/
ORIENTATION
SLOPE/TILT
VOC @ Jbox
VOC @ Inverter
V+ to Gnd
V- to Gnd
AC L1-L2
AC L1-N
AC L2-N
AC POWER
WATTS @
TIME OF DAY
AMBIENT TEMP.
WEATHER SUNNY PARTLY CLOUDY CLOUDY
INVERTER M/N
INVERTER S/N
STRING CONFIG
(1 column each
MPPT)
INPUT #1 2
AZIMUTH/
ORIENTATION
SLOPE/TILT
VOC @ Jbox
VOC @ Inverter
V+ to Gnd
V- to Gnd
AC L1-L2
AC L1-N
AC L2-N
AC POWER
WATTS @
TIME OF DAY
AMBIENT TEMP.
WEATHER SUNNY PARTLY CLOUDY CLOUDY
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
STRING CONFIG
(1 column each
MPPT)
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Ra
n
k
i
n
R
e
s
i
d
e
n
c
e
21109
42
6
2
0
A
d
a
l
i
n
W
a
y
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
1
1
5/11/2021
SF
MJR
Sheet
Michael Rango
PV-2.0
RO
O
F
P
L
A
N
1" = 5'
MOUNT PLAN KEYNOTE:
RACK MOUNT COMPONENTS
1.1 UNIRAC ALUMINUM SUPPORT RAIL
1.2 PEGASUS TILE REPLACEMENT MOUNTS
STRUCTURAL
2.1 ROOF SUPPORTS 2x4 ENGINEERED TRUSS
(24" O.C.)
1.VERIFY RAFTER SPACING IN THE FIELD BEFORE
ATTACHING MOUNTS ROOF.
2.ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF
RAFTERS AND MAKE STRUCTURAL CONNECTION TO
THE RAFTERS.
3.STRUCTURAL CONNECTION TO ENGINEERED TRUSS
SHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAG
SCREWS 3" MIN. EMBEDMENT.
4.ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS.
5.PHOTOVOLTAIC MODULES SHALL HAVE 1.4 MOUNTS
(LAG SCREWS) PER PANEL.
6.(E) ROOF STRUCTURE IS 18 DEGREE 2X4 ENGINEERED
TRUSS 24" O.C TYP.
7.(E) ROOFING MATERIAL IS 1 LAYER OF CONCRETE
TILES OVER 1 LAYER OF 30LB. FELT PAPER AND 1/2"
OSB PLYWOOD DECKING.
8.MODULE DIMENSIONS 65.9" x 39.25"
48" SPACING BETWEEN MOUNTS IS TYPICAL - MAX SPAN 6'
NOTES:EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690, 705 , 706 AND OTHERS.
1. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS A PHOTOVOLTAIC
DISCONNECT.
2. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING-ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS-TERMINALS ON BOTH
THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION"
3. PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2. INVERTER OUTPUT
VOLTAGE
4. LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS PER NEC 690-64(b)7.
5. INDIVIDUAL INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE.
6.ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE.
7.ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBLE TO ANYONE OTHER THAN QUALIFIED PERSONS.
8.ALL PV SYSTEM EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY.
9.ALL EXTERIOR WIRING MATERIAL SHALL BE SUITABLE FOR A SUN EXPOSURE AND WET LOCATIONS.
10.REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR OUTPUT CIRCUIT
CONDUCTOR.
11.CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED.
12.ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2019 CALIFORNIA ELECTRIC CODE & NEC 2020 705.13.
13.BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT.
SOLAREDGE POWER OPTIMIZER P400
RATED DC INPUT POWER - 400 WATTS
MAXIMUM INPUT VOLTAGE - 80 VDC
MPPT RANGE - 8 TO 80 VDC
MAXIMUM INPUT CURRENT - 12.5 ADC
MAXIMUM OUTPUT CURRENT - 15 ADC
STRING LIMITATIONS - 8 TO 25 OPTIMIZERS,
5250 WATTS STC PER STRING MAXIMUM
J-BOX
BA
AC OUT
PV DC INEQ
U
I
P
M
E
N
T
G
R
O
U
N
D
I
N
G
C
O
N
D
U
C
T
O
R
(1
)
#
6
A
W
G
B
A
R
E
B
O
N
D
E
D
T
O
G
R
O
U
N
D
TR
A
C
K
R
A
I
L
S
A
N
D
P
V
M
O
D
U
L
E
S
1 STRING OF 9
SolarEdge systems are not solidly grounded (functional grounded)
PV systems as permitted under Article 690.47.
C
SE6000H-US = 25A x 1.25 = 31.25A
125A x 1.2 = 150A
150A - 100A = 50A
31.25A <= 50A
(N)
SYSTEM DISCONNECT
ADJACENT TO INVERTER
60A/240V
5,525 WATT DC (5,116 WATT AC)
SOLAR ELECTRIC ARRAY
17 REC 325 WATT MODULES
MODEL NO. REC325NP
17 x 304.0 PTC x 99% EFF = 5.116 kW AC
INDIVIDUAL MODULE RATING:
PTC = 304.0 WATTS
Voc = 41 VDC
Isc = 10.27 AMPS
(E)
MAIN SERVICE PANEL
125A BUSS, 120/240V, 1PH, 3W
100A
MAIN
BREAKER
EXISTING
LOADS
EXISTING AC GEC
INTEGRATED GFCI AND
240 VAC, 25 AMPS MAX
OUTPUT: 6000 WATTS MAX
INPUT: 400 TO 480 VDC
GRID-TIE INVERTER
SOLAREDGE SE6000H-US
OUTPUT EFFICIENCY: 99%
DC DISCONNECTS
35A
1 STRING OF 8
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Ra
n
k
i
n
R
e
s
i
d
e
n
c
e
21109
42
6
2
0
A
d
a
l
i
n
W
a
y
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
1
1
5/11/2021
SF
MJR
Sheet
Michael Rango
PV-3.0
SI
N
G
L
E
L
I
N
E
D
I
A
G
R
A
M
NTS
8.5"
12.7"
1.6"
0.6"6.8"
4.1"
1.5"
5.7"
13"
18"
1.1 EPDM BOOT
1.2 1.5"x 5.7" MOUNTING POST
1.3 S-TILE REPLACEMENT FLASHING
1.4 3.5" X 5/16" SS LAG BOLTS
1.5 ADJUSTABLE MOUNTING SLED
1.6 BASE FLASHING
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Ra
n
k
i
n
R
e
s
i
d
e
n
c
e
21109
42
6
2
0
A
d
a
l
i
n
W
a
y
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
1
1
5/11/2021
SF
MJR
Sheet
Michael Rango
PV-4.0
AT
T
A
C
H
M
E
N
T
D
E
T
A
I
L
NTS
WARNING
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE AND LOAD SIDE
MAYBE ENERGIZED IN THE OPEN POSITION
DC DISCONNECTS AND J-BOXES
CAUTION:
SOLAR ELECTRIC SYSTEM CONNECTED
PLACE ON MSP
CONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTING
ALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BE
INSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALL
ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED.
CEC ARTICLES 690.56(B) AND 705.10.
FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALL
LETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHER
RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT.
NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B)(2)
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
CEC 690.56(C)(1)(A)
Label for PV Systems that shut down the array and the conductors leaving the array.
The title “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” shall utilize capitalized characters with a
minimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall be
capitalized with a minimum height of 4.8 mm (3∕16 in.) in black on white background.
PLACE ON PV SYSTEM DISCONNECT
PV SYSTEM DISCONNECT
WARNING
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE
THIS OVER CURRENT DEVICE
ADJACENT TO BACK FED BREAKER
705.12(B)(1)(3)(b)
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
PLACE NEXT TO INVERTER AC DISCONNECTS
690.56(C)(3)
WARNING:
PHOTOVOLTAIC POWER SOURCE
CONDUITS AND RACEWAYS EVERY 10'
690.31(G)(3)
PV INVERTER
SERVICE PANEL (YOU ARE HERE)SYSTEM AC DISCONNECT
HOT PURPLE ENERGY
760.322.4433N
1 2
3
LEGEND:
THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR
PANELS ON ROOF
CAUTION
42620 ADALIN WAY, PALM DESERT, CA 92211
MAXIMUM VOLTAGE 480 V
MAXIMUM CIRCUIT CURRENT 16.5 A
MAX RATED OUTPUT CURRENT OF
THE CHARGE CONTROLLER
OR DC-TO-DC CONVERTER
(IF INSTALLED)15A
SE6000H-US
PLACE ON DC DISCONNECT
PV SYSTEM AC DISCONNECT
WARNING - DUAL POWER SOURCE
SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM
MAX AC CURRENT : 25 A
AC VOLTAGE : 240 V
PLACE ON SYSTEM DISCONNECTS
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
H
P
Sheet Number:
Job Number:
Ti
t
l
e
:
Checked by:
Date:
Scale:
Revisions:Date:
Drawn by:
81
0
N
.
F
a
r
r
e
l
l
D
r
i
v
e
Pa
l
m
S
p
r
i
n
g
s
,
C
A
9
2
2
6
2
(7
6
0
)
3
2
2
-
4
4
3
3
o
f
f
i
c
e
Li
c
e
n
s
e
N
o
.
9
4
0
5
5
0
in
f
o
@
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
ww
w
.
H
o
t
P
u
r
p
l
e
E
n
e
r
g
y
.
c
o
m
IN
T
E
G
R
A
T
O
R
:
Michael Rango
760.322.4433 Lic. No. 940550
Ra
n
k
i
n
R
e
s
i
d
e
n
c
e
21109
42
6
2
0
A
d
a
l
i
n
W
a
y
Pa
l
m
D
e
s
e
r
t
,
C
A
9
2
2
1
1
5/11/2021
SF
MJR
Sheet
Michael Rango
PV-5.0
WA
R
N
I
N
G
L
A
B
E
L
S
NTS