Loading...
HomeMy WebLinkAboutSOLR22-1132 APPROVED REVISED PLANS (2).pdfH o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Jo w i t t R e s i d e n c e 22194 47 3 0 8 A b d e l C i r c l e Pa l m D e s e r t , C A 9 2 2 6 0 9/13/2022 SF MJR Sheet Michael Rango PV-0.0 CO V E R S H E E T DESCRIPTION OF WORK: ROOF MOUNTED PHOTOVOLTAIC (SOLAR ELECTRIC) INSTALLATION TILT MOUNTED @ 3° FACING AN AZIMUTH OF 179° AND 269° CONSISTING OF (26) PANASONIC EVPV400H 400 WATT MODULES (10.4Kw). RACK MOUNTING SYSTEM IS UNIRAC SOLARMOUNT ALUMINUM SUPPORT RAILS AND FAST JACK SOLAR STANCHIONS. INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES: CEC 2019 - ARTICLE 690, 705,706 AND OTHERS NEC 2020 705.13 CPC 2019 CBC 2019 CMC 2019 CFC 2019 DRAWING SHEETS: COVER SHEET PV-0.0 OPTIMIZER STRINGING NOTES (NOT FOR PERMITTING)PV-0.0 (2) SITE PLAN PV-1.0 SYSTEM PERFORMANCE NOTES (NOT FOR PERMITTING)PV-1.0 (2) ROOF PLAN PV-2.0 ROOF PLAN (continued) PV-2.1 SINGLE LINE DIAGRAM PV-3.0 MOUNTING DETAIL PV-4.0 WARNING LABELING PV-5.0 SPECIFICATION SHEETS: EVPV400H MODULE SE10000H-US INVERTER UNIRAC CERTIFICATION NTS GENERAL NOTES: 1.ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDER THE DIRECT SUPERVISION OF A LICENSED ELECTRICIAN. 2.ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741SA CERTIFIED AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVED FOR IT'S PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. 3.THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAIC SYSTEM WHEN THE UTILITY GRID IS NOT IN OPERATION. 4.PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCAL AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. 5.THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ON THE ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE PHOTOVOLTAIC SYSTEM OR INSTALLATION. 6.ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS. 7.ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS. 8.TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTURE Palm Desert Municipal Code Requirements: (required on first page) Basic Wind Speed: (3 second gust) •Risk Category IV - 108 mph (Palm Desert use Category IV) CONSTRUCTION HOURS: OCTOBER 1 THRU APRIL 30 MAY 1 THRU SEPTEMBER 30 Monday - Friday 7:00 a.m. - 5:30 p.m. Monday - Friday 5:30 a.m. - 7:00 p.m. Saturday 8:00 a.m. - 5:00 p.m. Saturday 8:00 a.m. - 5:00 p.m. Sunday NOT ALLOWED Sunday NOT ALLOWED Government Code Holidays-- NOT ALLOWED A violation of the above work hours is a citable offense under Palm Desert Municipal Code Section 9.24.070. Rev A 12/5/22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 OPTIMIZER / STRINGING (INSTALLATION NOTES NOT FOR PERMITTING) Panel S/N: ° ABDEL CIRCLE H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Jo w i t t R e s i d e n c e 22194 47 3 0 8 A b d e l C i r c l e Pa l m D e s e r t , C A 9 2 2 6 0 9/13/2022 SF MJR Sheet Michael Rango PV-1.0 SI T E P L A N 1" = 15' SITE PLAN KEYNOTE: EXISTING ELECTRICAL 1.1 225A MAIN ELECTRICAL PANEL NEW ELECTRICAL (ADJACENT TO MSP) 2.1 SYSTEM AC DISCONNECT NEW ELECTRICAL (INSIDE GARAGE) 2.2 SYSTEM AC DISCONNECT 2.3 SE10000H-US PV INVERTER SITE LEGEND EAVE SETBACK/WALL Rev A 12/5/22 SYSTEM PERFORMANCE (INSTALLATION NOTES NOT FOR PERMITTING) CREW NOTES: INVERTER M/N INVERTER S/N STRING CONFIG (1 column each MPPT) INPUT #1 2 AZIMUTH/ ORIENTATION SLOPE/TILT VOC @ Jbox VOC @ Inverter V+ to Gnd V- to Gnd AC L1-L2 AC L1-N AC L2-N AC POWER WATTS @ TIME OF DAY AMBIENT TEMP. WEATHER SUNNY PARTLY CLOUDY CLOUDY INVERTER M/N INVERTER S/N STRING CONFIG (1 column each MPPT) INPUT #1 2 AZIMUTH/ ORIENTATION SLOPE/TILT VOC @ Jbox VOC @ Inverter V+ to Gnd V- to Gnd AC L1-L2 AC L1-N AC L2-N AC POWER WATTS @ TIME OF DAY AMBIENT TEMP. WEATHER SUNNY PARTLY CLOUDY CLOUDY INVERTER M/N INVERTER S/N STRING CONFIG (1 column each MPPT) INPUT #1 2 AZIMUTH/ ORIENTATION SLOPE/TILT VOC @ Jbox VOC @ Inverter V+ to Gnd V- to Gnd AC L1-L2 AC L1-N AC L2-N AC POWER WATTS @ TIME OF DAY AMBIENT TEMP. WEATHER SUNNY PARTLY CLOUDY CLOUDY STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Jo w i t t R e s i d e n c e 22194 47 3 0 8 A b d e l C i r c l e Pa l m D e s e r t , C A 9 2 2 6 0 9/13/2022 SF MJR Sheet Michael Rango PV-2.0 RO O F P L A N 1" = 5' 1.VERIFY RAFTER SPACING IN THE FIELD BEFORE ATTACHING MOUNTS ROOF. 2.ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF RAFTERS AND MAKE STRUCTURAL CONNECTION TO THE RAFTERS. 3.STRUCTURAL CONNECTION TO ENGINEERED TRUSS SHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAG SCREWS 3" MIN. EMBEDMENT. 4.ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS. 5.PHOTOVOLTAIC MODULES SHALL HAVE 1.7 MOUNTS (LAG SCREWS) PER PANEL. 6.(E) ROOF STRUCTURE IS FLAT 2X10 ENGINEERED TRUSS/JOIST 16" O.C TYP. 7.(E) ROOFING MATERIAL IS 1 LAYER OF FOAM OVER 1 LAYER OF 30LB. FELT PAPER AND 1/2" OSB PLYWOOD DECKING. 8.MODULE DIMENSIONS 71.7" x 40" MOUNT PLAN KEYNOTE: RACK MOUNT COMPONENTS 1.1 UNIRAC ALUMINUM SUPPORT RAIL 1.2 FAST JACK SOLAR STANCHIONS STRUCTURAL 2.1 ROOF SUPPORTS 2x10 ENGINEERED TRUSS/JOIST (16" O.C.) 48" SPACING BETWEEN MOUNTS IS TYPICAL - MAX SPAN 6' Rev A 12/5/22 H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Jo w i t t R e s i d e n c e 22194 47 3 0 8 A b d e l C i r c l e Pa l m D e s e r t , C A 9 2 2 6 0 9/13/2022 SF MJR Sheet Michael Rango PV-2.1 RO O F P L A N 1" = 5' 1.VERIFY RAFTER SPACING IN THE FIELD BEFORE ATTACHING MOUNTS ROOF. 2.ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF RAFTERS AND MAKE STRUCTURAL CONNECTION TO THE RAFTERS. 3.STRUCTURAL CONNECTION TO ENGINEERED TRUSS SHALL BE MADE BY 3-1/2" X 5/16" STAINLESS STEEL LAG SCREWS 3" MIN. EMBEDMENT. 4.ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS. 5.PHOTOVOLTAIC MODULES SHALL HAVE 1.5 MOUNTS (LAG SCREWS) PER PANEL. 6.(E) ROOF STRUCTURE IS FLAT 2X10 ENGINEERED TRUSS/JOIST 16" O.C TYP. 7.(E) ROOFING MATERIAL IS 1 LAYER OF FOAM OVER 1 LAYER OF 30LB. FELT PAPER AND 1/2" OSB PLYWOOD DECKING. 8.MODULE DIMENSIONS 71.7" x 40" MOUNT PLAN KEYNOTE: RACK MOUNT COMPONENTS 1.1 UNIRAC ALUMINUM SUPPORT RAIL 1.2 FAST JACK SOLAR STANCHIONS STRUCTURAL 2.1 ROOF SUPPORTS 2x10 ENGINEERED TRUSS/JOIST (16" O.C.) 48" SPACING BETWEEN MOUNTS IS TYPICAL - MAX SPAN 6' Rev A 12/5/22 C AC OUT PV DC IN 2 STRINGS OF 13 J-BOX BA SOLAREDGE POWER OPTIMIZER P400 RATED DC INPUT POWER - 400 WATTS MAXIMUM INPUT VOLTAGE - 80 VDC MPPT RANGE - 8 TO 80 VDC MAXIMUM INPUT CURRENT - 12.5 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5250 WATTS STC PER STRING MAXIMUM C 200A BREAKER (E) MAIN SERVICE PANEL 225A BUSS, 120/240V, 1PH, 3W MSP 60A SE10000H-US = 42A x 1.25 = 52.5A 225A x 1.2 = 270A 270A - 200 = 70A 52.5A <= 70A (N) PV DISCONNECT DG322URB ADJACENT TO INVERTER 60A/240V 60A 60A/240V (N) SYSTEM DISCONNECT DG322NRB ADJACENT TO MSP EXISTING AC GROUNDING ELECTRODE CONDUCTOR PROVIDE NEW ELECTRODE IF NOT EXISTING PER CEC 250.53 (A)(2) 10,400 WATT DC (9,807 WATT AC) SOLAR ELECTRIC ARRAY 26 PANASONIC 400 WATT MODULES MODEL NO. EVPV400H 26 x 381.0 PTC x 99% EFF = 9.807 kW AC INDIVIDUAL MODULE RATING: PTC = 381.0 WATTS Voc = 48.8 VDC Isc = 10.25 AMPS INTEGRATED GFCI AND 240 VAC, 42 AMPS MAX OUTPUT: 10000 WATTS MAX INPUT: 400 TO 480 VDC GRID-TIE INVERTER SOLAREDGE SE10000H-US OUTPUT EFFICIENCY: 99% DC DISCONNECTS NOTES:EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690, 705 , 706 AND OTHERS. 1. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS A PHOTOVOLTAIC DISCONNECT. 2. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING-ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS-TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION" 3. PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2. INVERTER OUTPUT VOLTAGE 4. LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS PER NEC 690-64(b)7. 5. INDIVIDUAL INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE. 6.ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE. 7.ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBLE TO ANYONE OTHER THAN QUALIFIED PERSONS. 8.ALL PV SYSTEM EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY. 9.ALL EXTERIOR WIRING MATERIAL SHALL BE SUITABLE FOR A SUN EXPOSURE AND WET LOCATIONS. 10.REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR OUTPUT CIRCUIT CONDUCTOR. 11.CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED. 12.ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2019 CALIFORNIA ELECTRIC CODE & NEC 2020 705.13. 13.BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT. 14.ANY LOADS RELOCATED TO A BU LOADS PANEL BEYOND SIX FEET SHALL REQUIRE AFCI PROTECTION. H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Jo w i t t R e s i d e n c e 22194 47 3 0 8 A b d e l C i r c l e Pa l m D e s e r t , C A 9 2 2 6 0 9/13/2022 SF MJR Sheet Michael Rango PV-3.0 SI N G L E L I N E D I A G R A M NTS Rev A 12/5/22 Scale: 1" = 1' 5-7 DEGREE TILT DETAIL1 MOUNT DETAIL KEYNOTE: RACK MOUNT COMPONENTS 1.1 PHOTOVOLTAIC MODULE 1.2 MODULE CLAMP 1.3 UNIRAC "SOLARMOUNT" SUPPORT RAIL 1.4 SS RAIL T-BOLT AND NUT 1.5 UNIRAC L-FOOT 1.6 ADJUSTABLE ALL TREAD 1.7 FAST JACK SOLAR STANCHION (4.5" - 7" typical) 1.8 3.5" SS LAG SCREWS (3" minimum embedment ) STRUCTURAL 2.1 FOAM ROOF 2.2 30LB FELT PAPER 2.3 1/2" OSB ROOF DECKING 2.4 2 x 10 ENGINEERED TRUSS (RAFTER) 16" O.C. TYP.H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Jo w i t t R e s i d e n c e 22194 47 3 0 8 A b d e l C i r c l e Pa l m D e s e r t , C A 9 2 2 6 0 9/13/2022 SF MJR Sheet Michael Rango PV-4.0 AT T A C H M E N T D E T A I L 1" = 5' Rev A 12/5/22 WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAYBE ENERGIZED IN THE OPEN POSITION DC DISCONNECTS AND J-BOXES CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PLACE ON MSP CONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTING ALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BE INSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. CEC ARTICLES 690.56(B) AND 705.10. FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALL LETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B)(2) TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS CEC 690.56(C)(1)(A) Label for PV Systems that shut down the array and the conductors leaving the array. The title “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” shall utilize capitalized characters with a minimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall be capitalized with a minimum height of 4.8 mm (3∕16 in.) in black on white background. WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE ADJACENT TO BACK FED BREAKER 705.12(B)(1)(3)(b) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PLACE NEXT TO INVERTER AC DISCONNECTS 690.56(C)(3) WARNING: PHOTOVOLTAIC POWER SOURCE CONDUITS AND RACEWAYS EVERY 10' 690.31(G)(3) SERVICE PANEL (YOU ARE HERE)SYSTEM AC DISCONNECT HOT PURPLE ENERGY 760.322.4433N 1 2 43 LEGEND: THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR PANELS ON ROOF CAUTION 47308 ABDEL CIRCLE, PALM DESERT, CA 92260 PV INVERTERSYSTEM AC DISCONNECT MAXIMUM VOLTAGE 480 V MAXIMUM CIRCUIT CURRENT 27 A MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED)15A SE10000H-US PLACE ON DC DISCONNECT PV SYSTEM AC DISCONNECT WARNING - DUAL POWER SOURCE SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM MAX AC CURRENT : 42 A AC VOLTAGE : 240 V PLACE ON SYSTEM DISCONNECTS PLACE ON PV SYSTEM DISCONNECT PV SYSTEM DISCONNECT H o t P u r p l e E n e r g y H P Sheet Number: Job Number: Ti t l e : Checked by: Date: Scale: Revisions:Date: Drawn by: 81 0 N . F a r r e l l D r i v e Pa l m S p r i n g s , C A 9 2 2 6 2 (7 6 0 ) 3 2 2 - 4 4 3 3 o f f i c e Li c e n s e N o . 9 4 0 5 5 0 in f o @ H o t P u r p l e E n e r g y . c o m ww w . H o t P u r p l e E n e r g y . c o m IN T E G R A T O R : Michael Rango 760.322.4433 Lic. No. 940550 Jo w i t t R e s i d e n c e 22194 47 3 0 8 A b d e l C i r c l e Pa l m D e s e r t , C A 9 2 2 6 0 9/13/2022 SF MJR Sheet Michael Rango PV-5.0 WA R N I N G L A B E L S NTS Rev A 12/5/22