Loading...
HomeMy WebLinkAboutfinal planset (2)76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com March 27, 2023 Infinity Energy 3855 Atherton Road Rocklin, CA 95765 Re: Engineering Services Macmurdo Residence 73705 Agave Lane, Palm Desert CA 13.200 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A.Site Assessment Information 1.Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2.Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B.Description of Structure: Roof Framing: Prefabricated wood trusses at 24” on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Tile roofing Roof Slope: 18 degrees Attic Access: Accessible Foundation: Permanent C.Loading Criteria Used •Dead Load o Existing Roofing and framing = 14 psf o New Solar Panels and Racking = 3 psf o TOTAL = 17 PSF •Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf •Live Load = 20 psf (reducible) – 0 psf at locations of solar panels •Ground Snow Load = 0 psf •Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 97 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2022 California Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D.Solar Panel Anchorage 1.The solar panels shall be mounted in accordance with the most recent Ecofasten installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation.2.The maximum allowable withdrawal force for a 5/16” lag screw is 229 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 3”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 3” embedment will be adequate and will include a sufficient factor of safety.3.Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 72” on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2022 California Residential Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE California License No. 83664 INSTALLATION CONSISTS OF 33 HANWHA Q CELLS:Q.PEAK DUO BLK ML-G10+ 400 PV MODULES, 33 ENPHASE ENERGY: IQ8PLUS-72-2-US AND RELATED ELECTRICAL METERING (IF USED) AND SAFETY EQUIPMENT. ALL COMPONENTS ARE UL LISTED AND NEC CERTIFIED, WHERE WARRANTED ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLE CODES AND LOCAL UTILITY COMPANY REQUIREMENTS. RICHARD W MACMURDO 73705 AGAVE LANE PALM DESERT CA, 92260 CASH CITY OF PALM DESERT 3/28/2023 RAYYAN HARAHAP 655100032 Rayyan Harahap CITY: SYSTEM INFORMATIONVICINITY MAP SHEET INDEX IE-01 - TITLE SHEET IE-02 - SITE PLAN IE-03 - MOUNTING LAYOUT IE-04 - ELECTRICAL DIAGRAM IE-05 - LABELING LEGEND ·A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS. ·THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM. ·A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47, 250.50 THROUGH 60, AND 250.166 SHALL BE PROVIDED. PER CEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE OR A COMPLETE GROUND. ·EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED BY THE MANUFACTURER. ·EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH CEC 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. ·PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED PER CEC 110.26. ·ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC. ·HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6' 7" PER CEC 240.24. ·THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER CEC 250.64(B). THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER CEC 250.64(C). ·ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES. ·THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER CEC 705.12 (B)(3)(2). ·SITE CONDITIONS SHALL PREVAIL IF NO SCALE IS GIVEN. DRAWINGS ARE NOT NECESSARILY TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR UPON COMMENCEMENT OF CONSTRUCTION. ·PER THE CA RESIDENTIAL CODE (CRC) § R314 & R315, 10 YEAR BATTERY CARBON MONOXIDE AND SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING AREA AND HALLWAYS LEADING TO SLEEPING AREAS. SCOPE OF WORK APPLICABLE CODES 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) WIND SPEED: 97 MPH EXPOSURE: C STRUCTURE TYPE: RESIDENTIAL OCCUPIED BUILDING ROOF FRAMING: 2"X8" RAFTERS, 24" O.C. ROOF TYPE: S - TILE STORIES: 1 SYSTEM SIZE 13.20 kW DC / 12.80 kW AC DESIGN CRITERIA EXISTING BUILDING INFORMATION SNOW LOAD: 0 PSF PV MODULES INVERTERS RACKING MOUNTING 33 HANWHA Q CELLS:Q.PEAK DUO BLK ML-G10+ 400 33 ENPHASE ENERGY: IQ8PLUS-72-2-US ECOFASTEN ROCK-IT ECOFASTEN ROCK-IT CONSTRUCTION NOTES TITLE SHEET IE - 01 M A/C BREAKER FUSE SWITCH CONDUIT RUN GROUND ELECTRODE CURRENT CARRYING CONDUCTOR METER INVERTER WIRELESS AIR CONDITIONER CHIMNEYNNEUTRAL CONDUCTOR G GROUNDING CONDUCTOR POWER OPTIMIZER PROJECT INFORMATION ADDRESS: CITY: STATE, ZIP: AHJ: APN#: FINANCE TYPE: DRAWN BY: DATE: NAME: AHJ SIGNATURE DATE PCGI 31566 Railroad Canyon RD STE 2-29 CSLB# 1074469 T: (916) 240-1962 Canyon Lake, CA 92587 Signed 3/27/2023 DRIVEWAY 73705 AGAVE LANE AZIMUTH AND SLOPE MOUNTING PLANE AZIMUTH MP1 13MODULE COUNT MP2 20 1818 234143 TILT (Degrees) COORDINATES: (33.6968075,-116.3780508) COMBINER BOX 33 HANWHA Q CELLS:Q.PEAK DUO BLK ML-G10+ 400 W/ 33 ENPHASE ENERGY: IQ8PLUS-72-2-US LEGEND: 3' SETBACK 18" SETBACK MAIN SERVICE PANEL Scale:1" = 15' JUNCTION BOX MP1 EXTERNAL 3 4" CONDUIT MP2 S - TILE R324.6.2 - PROVING ARRAYS TAKE LESS THAN 33% OF TOTAL ROOF AREA.WHEN THE ARRAYS TAKE LESS THAN 33% WE CAN JUSTIFY AN 18" SETBACK ON BOTH SIDES OF THE RIDGE. WHEN IT TAKES MORE THAN 33% OF THE ROOF AREA WE MUST USE A 3' SETBACK ON BOTH SIDES OF THE RIDGE. TOTAL ROOF AREA: 2650 sqft AREA OF ARRAYS: 3'-5" x 6'-2" ( PANEL DIMENSIONS) 41.04" x 74.04" = 21.10 sqft panel 21.10 sqft panel X 33 panels = 696.35 sqft (TOTAL PANEL AREA) PERCENTAGE OF TOTAL ROOF AREA: (696.35 sqft / 2650 sqft)(100)= 26.28% ∴THE PANELS USE 26.28% OF THE TOTAL ROOF AREA SITE PLAN IE - 02 RICHARD W MACMURDO 73705 AGAVE LANE PALM DESERT CA, 92260 CASH CITY OF PALM DESERT 3/28/2023 RAYYAN HARAHAP 655100032 Rayyan Harahap PROJECT INFORMATION ADDRESS: CITY: STATE, ZIP: AHJ: APN#: FINANCE TYPE: DRAWN BY: DATE: NAME: AHJ SIGNATURE DATE PCGI 31566 Railroad Canyon RD STE 2-29 CSLB# 1074469 T: (916) 240-1962 Canyon Lake, CA 92587 UTILITY GAS RISER SWIMMING POOL HIP RIDGE RIDGE VALLEY COMP OUT COMP OUT ENGINEERED FOR 130 MPH WINDS AND EXPOSURE C HIP HIP RIDGE PATIO COVER Signed 3/27/2023 APPROXIMATE DEAD LOAD FIGURES PANEL WEIGHT (pounds) WEIGHT (pounds) / SQ FT RACKING TOTAL LBS PER SQ FT 4.8 LBS 2.1 LBS 4.4 PSF WEIGHT (pounds / lin. ft.) WEIGHT (pounds) / SQ FT 48.5 LBS 2.3 PSF Scale:1" = 10' ECOFASTEN ROCK-IT ROOF ATTACHMENT MUST BE STAGGERED ROOF ATTACHMENT DETAIL 6" Max FLASHING (TYP) ROCKIT CLAMP ASSY (TYP) 516" x 4" LAG 2-12" EMBEDMENT MIN. ROCK-IT 4" SLIDE ROCK-IT SHELF COMP SHINGLE ROOF ECOFASTEN ROCK IT SYSTEM SPACING OF MOUNTS ARE A MAXIMUM 6' SPAN (STAGGERED) RAFTER ROOF FRAMING DETAIL 2"x8" RAFTER, 24" O.C. PANELS 3 4" PLYWOOD DECKING COMP SHINGLE ROOF MOUNTING LAYOUT IE - 03 RICHARD W MACMURDO 73705 AGAVE LANE PALM DESERT CA, 92260 CASH CITY OF PALM DESERT 3/28/2023 RAYYAN HARAHAP 655100032 Rayyan Harahap PROJECT INFORMATION ADDRESS: CITY: STATE, ZIP: AHJ: APN#: FINANCE TYPE: DRAWN BY: DATE: NAME: AHJ SIGNATURE DATE PCGI 31566 Railroad Canyon RD STE 2-29 CSLB# 1074469 T: (916) 240-1962 Canyon Lake, CA 92587 S - TILE 2"X8" RAFTERS, 24" O.C. COMP OUT COMP OUT Signed 3/27/2023 J- B O X G 18" MAX DC Equipment Grounding Conductor per 690.43 #6 BARE COPPER PV MODULES (TYP) 1 (N) ENPHASE COMBINER BOX COMBINER BOX 4 W / IQ GATEWAY / CELL MODEM-M1-06-SP-05 (E) MAIN ELECTRICAL SERVICE PANEL 225A RATED, 240V, 2P, WITH 200A MAIN BREAKER (E) UTILITY METER OB J . COMPONENT 33 ENPHASE ENERGY: IQ8PLUS-72-2-US W/ RAPID SHUTDOWN (N) J-BOX CANTEX JUNCTION BOX (N) BRANCH OF MICROINVERTERS IN PARALLEL (N) SOLAR PV MODULES 33 HANWHA Q CELLS:Q.PEAK DUO BLK ML-G10+ 400 SOUTHERN CALIFORNIA EDISON - SCE UTILITY METER #: 222012-318977 690.12 RAPID SHUTDOWN COMPLIANT (TYP) 1 3 A (TYP) SOLAR OCPD OUTPUT PER MICROINVERTER 290W / 240V = 1.21A TOTAL OUTPUT 33 MICROINVERTERS 33*1.21A = 39.88A CONTINUOUS LOAD RULE 125% 39.88A*1.25 = 49.84A ∴ SIZE 50A G AC DISCONNECT 2 5 C MONITOR OCPD Size: 15A (2P) ENVOY PV OCPD Size: 20A (2P) CELL MODEM G 4 BUILDING GROUNDING ELECTRODE M MAIN PANEL BUS Size: 225A7 G END FED MAIN SERVICE PANEL MAIN OCPD Size:200A (2P) Meter #: 222012-318977 8 (E) LOADS 6 2 3 4 5 6 7 (N) DISCONNECT 60A NON FUSIBLE - DG222NRB PV MODULES (TYP) C PV MODULES (TYP) BRANCH OF 11 MODULES BRANCH OF 11 MODULES BRANCH OF 11 MODULES ENPHASE Q CABLE 2 Conductor Type: THWN-2 UL3003, DG CABLE 2 B 2 2 DESCRIPTION # OF CURRENT CARRYING CONDUCTORSEL E C . T A G CONDUCTOR CONDUCTOR TEMPERATURE DERATING CORRECTED AMPACITY HEIGHT ABOVE ROOF AMBIENT TEMP (°C) AMPACITY CORRECTION 310.15(B)(2) AMP CORR 310.15(C)(1) ORIG. AMPS TEMP DER. CT DER. CORR. AMPS* * = CONDUIT SIZE MAX AMPS FOR A 75°C RATED TERMINAL 90°C RATED THWN-2 @ 30°C PER 310.16 CONDUIT CONDUCTOR COUNT ADJ FACTOR USABLE AMPS GROUNDING WIRE SIZE = MAX OCPD (PROTECTED UNLESS STATED) (NEUTRAL SIZED THE SAME AS CURRENT CARRYING CONDUCTORS) N/A .87 1 44°C#8 AWG (90°C Cu) = 75A 75A* 1 *.87 = 65.3A 65.0A 65.0A 2 CONDUCTORS 3/4" LFMC #8 AWG (Cu)C >7/8"#10 AWG (90°C Cu) = 40A .87 35.0A 44°C #8 AWG (Cu)B #6 AWG (Cu)N/A N/A FREE AIR N/A N/A N/A 20.0AQ CABLEA >7/8"44°C 6 CONDUCTORS .8 3/4" EMT 40A* .8 *.87 = 27.8A 27.8A 1 ELECTRICAL DIAGRAM KEYNOTES GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION, LOAD CENTER, AND/OR DISCONNECTS. DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ (AUTHORITY HAVING JURISDICTION). PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CODES. AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 18 INCH OF UTILITY METER. AC DISCONNECTS TO BE LOCKABLE, LABELED, AND KNIFE-BLADE TYPE. PER NEC REQUIREMENTS, GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE PROTECTED IN A CONDUIT, RACEWAY, OR ARMORED PROTECTIVE SHEATHING (250.64) WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN TO INVERTER. ALL CONDUIT SHALL BE EMT 3/4" IN DIAMETER UNLESS OTHERWISE STATED. ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT (300.6 C1, 310.8 D) 2 3 4 5 6 RICHARD W MACMURDO 73705 AGAVE LANE PALM DESERT CA, 92260 CASH CITY OF PALM DESERT 3/28/2023 RAYYAN HARAHAP 655100032 Rayyan Harahap PROJECT INFORMATION ADDRESS: CITY: STATE, ZIP: AHJ: APN#: FINANCE TYPE: DRAWN BY: DATE: NAME: AHJ SIGNATURE DATE PCGI 31566 Railroad Canyon RD STE 2-29 CSLB# 1074469 T: (916) 240-1962 Canyon Lake, CA 92587 ELECTRICAL DIAGRAM IE - 04 LABELING NOTES 1. LABELING REQUIREMENTS BASED ON THE CALIFORNIA ELECTRICAL CODE, CALIFORNIA FIRE CODE CFC 1205.4.1, OSHA STANDARD 1910.145, CCR TITLE 8 §3340, ANSI Z535.4-2011 2. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED. 5. ALERTING WORDS TO BE COLOR CODED. "DANGER" WILL HAVE RED BACKGROUND; "WARNING" WILL HAVE ORANGE BACKGROUND; "CAUTION" WILL HAVE YELLOW BACKGROUND.[ANSI Z535.4-2011] DIRECTORY A PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS SHALL BE PROVIDED AT EACH SERVICE EQUIPMENT LOCATION AND PV SYSTEM DISCONNECTING MEANS IN ACCORDANCE WITH CEC 705.10. PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN BATHROOMS [CEC 690.4(E)] LABELING LETTERING TO BE AT LEAST 3 8" WHITE ON RED BACKGROUND; REFLECTIVE, UV RESISTANT STICKERS. [CEC 690.31(D)(2)] DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING RATED AC OUTPUT CURRENT: 39.88A NOMINAL OPERATING AC VOLTAGE: 240V RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED CAUTION PHOTOVOLTAIC AC DISCONNECT ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL 1 AT RAPID SHUTDOWN SYSTEM [CEC 690.56(C)] LABEL 2 AT EACH AC DISCONNECTING MEANS [CEC 690.13(B) AND 690.54] LABEL 3 AT POINT OF CONNECTION; LABEL, SUCH AS LABEL 2 OR LABEL 3 MUST IDENTIFY PHOTOVOLTAIC SYSTEM [CEC 705.12(B)(3)] LABEL 4 AT MAIN SERVICE PANEL, PULL BOXES [CEC 705.12(B)(3)] LABEL 5 AT RAPID SHUTDOWN SWITCH [CEC 690.56(C)(2)] LABEL 6 AT POINT OF INTERCONNECTION OVERCURRENT DEVICE [CEC 705.12(B)(2)(3)(B)] LABEL 7 AT EACH AC DISCONNECTING MEANS [CEC 690.13(B)] RICHARD W MACMURDO 73705 AGAVE LANE PALM DESERT CA, 92260 CASH CITY OF PALM DESERT 3/28/2023 RAYYAN HARAHAP 655100032 Rayyan Harahap PROJECT INFORMATION ADDRESS: CITY: STATE, ZIP: AHJ: APN#: FINANCE TYPE: DRAWN BY: DATE: NAME: AHJ SIGNATURE DATE PCGI 31566 Railroad Canyon RD STE 2-29 CSLB# 1074469 T: (916) 240-1962 Canyon Lake, CA 92587 LABELING IE - 05 MAIN SERVICE PANEL (YOU ARE HERE) COMBINER BOX 73705 AGAVE LANE N CAUTION POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCE(S) WITH DISCONNECTS LOCATED AS SHOWN. INSTALLED BY: PACIFIC COAST GENERATION MULTIPLE POWER SOURCES UTILITY GAS RISER BREAKING THE 20 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new “Quality Controlled PV” of the independent certification institute TÜV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. 1 APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Q.PEAK DUO BLK ML-G10+ 385-405 ENDURING HIGH PERFORMANCE 76.4 in 1940 mm 43.3 in 1100 mm 48.0 in 1220 mm 1656 lbs 751 kg 24 24 32 α [% / K]+0.04 β [% / K]−0.27 γ [% / K]−0.34 NMOT [°F]109 ± 5.4 (43 ± 3 °C) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us [V]1000 (IEC) / 1000 (UL)Class II [A DC]20 TYPE 2 [lbs/ft2]75 (3600 Pa) / 55 (2660 Pa) −40 °F up to +185 °F (−40 °C up to +85 °C)[lbs/ft2]113 (5400 Pa) / 84 (4000 Pa) 3 See Installation Manual 385 390 395 400 405 [W]385 390 395 400 405 [A]11.04 11.07 11.10 11.14 11.17 [V]45.19 45.23 45.27 45.30 45.34 [A]10.59 10.65 10.71 10.77 10.83 [V]36.36 36.62 36.88 37.13 37.39 [%]≥ 19.6 ≥ 19.9 ≥ 20.1 ≥ 20.4 ≥ 20.6 [W]288.8 292.6 296.3 300.1 303.8 [A]8.90 8.92 8.95 8.97 9.00 [V]42.62 42.65 42.69 42.72 42.76 [A]8.35 8.41 8.46 8.51 8.57 [V]34.59 34.81 35.03 35.25 35.46 53' 40' HC Certified UL 61730 MECHANICAL SPECIFICATION Format 74.0 in × 41.1 in × 1.26 in (including frame) (1879 mm × 1045 mm × 32 mm) Weight 48.5 lbs (22.0 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in (53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 49.2 in (1250 mm), (−) ≥ 49.2 in (1250 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © Q CE L L S Q. P E A K DU O BL K ML - G 1 0 + _ 3 8 5 - 4 0 5 _ 2 0 2 1 - 0 5 _ R e v 0 1 _ N A ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) Mi n i m u m Power at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP I MPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Mi n i m u m Power at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP I MPP Voltage at MPP VMPP 1Measurement tolerances PMPP ± 3 %; I SC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Maximum Series Fuse Rating Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull3 NA DETAIL A 0.63" (16 mm) 0.33" (8.5 mm)0.96" (24.5 mm) 42.8" (1088 mm) 74.0" (1879 mm) 4 × Mounting slots (DETAIL A) Frame 41.1" (1045 mm) 39.2" (996 mm) 1.26" (32 mm) 8 × Drainage holes 15.6“ (395.5 mm) 4 × Grounding points ø 0.18" (4.5 mm) Label ≥49.2" (1250 mm) ≥49.2" (1250 mm) EN RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P O W E R [ % ] YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 155 2520010 98 86 200 400 600 800 1000 110 100 90 80 RE L A T I V E E F F I C I E N C Y [ % ] IRRADIANCE [W/m²] QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 61730, CE-compliant, Quality Controlled PV - TÜV Rheinland, IEC 61215:2016, IEC 61730:2016, U.S. Patent No. 9,893,215 (solar cells), QCPV Certification ongoing. Horizontal packaging pallets pallets modules IQ8 and IQ8+ Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry- leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) requirements © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8SP-DS-0002-01-EN-US-2022-03-17 * Only when installed with IQ System Controller 2, meets UL 1741. ** IQ8 and IQ8Plus supports split phase, 240V installations only. DATA SHEET (1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (2) Maximum continuous input DC current is 10.6A (3) Nominal voltage range can be extended beyond nominal if required by the utility. (4) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 and IQ8+ Microinverters INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US Commonly used module pairings1 W 235 – 350 235 – 440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell, 66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range V 27 – 37 29 – 45 Operating range V 25 – 48 25 – 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current2 [module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal (L-L) voltage/range3 V 240 / 211 – 264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 AC short circuit fault current over 3 cycles Arms 2 Max units per 20 A (L-L) branch circuit4 16 13 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.5 97.6 CEC weighted efficiency %97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SP-DS-0002-01-EN-US-2022-03-17 X-IQ-AM1-240-4 The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 4/4C X-IQ-AM1-240-4 X-IQ-AM1-240-4C To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom, back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed X-IQ-AM1-240-4C To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. 10-21-2021 MODEL NUMBER IQ Combiner 4 (X-IQ-AM1-240-4)IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C (X-IQ-AM1-240-4C)IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Ensemble Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for Ensemble sites - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating 65 A Max. continuous current rating (input from PV/storage)64 A Max. fuse/circuit rating (output)90 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)80A of distributed generation / 95A with IQ Gateway breaker included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT)A pair of 200 A split core current transformers MECHANICAL DATA Dimensions (WxHxD)37.5 x 49.5 x 16.8 cm (14.75” x 19.5” x 6.63”). Height is 21.06" (53.5 cm) with mounting brackets. Weight 7.5 kg (16.5 lbs) Ambient temperature range -40º C to +46º C (-40º to 115º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 4/4C The solar adapter is used to connect between the Solar Panel Inverter, and the Customers Service Panel. The adapter is rated for 100A of back feed from the solar inverter to the customer service panel. The adapter is rated 200A continuous. There are conduit openings on top or bottom to allow the installation of weatherproof flex conduit from the inverter panel to the customer service panel. The adapter is UL Listed File # E142068 pped with a three terminal block in the center to allow quick installation of the conductors. Models available: 1000-0-R4-SP Solar UL LISTED File # E142068 The Solar Adapter is used to connect between the Solar Panel Inverter and the Customer’s Service Panel. The Adapter is Rated 80A Maximum of back feed from the solar inverter to the customer service panel. The adapter is rated 200A Continuous rated. There are available conduit openings on top or bottom to allow the installation of weatherproof flex conduit from the inverter panel to the customer service panel. The adapter is equipped with a three position terminal block in the center to allow quick installation of conductors. Marwell Solar Adapter E142068 Marwell Part # E/Z 1000-0-R-Solar Marwell Solar Adapter Mechanical Ratings Adapter Ratings Solar, EZ1000-0-R4- SP Solar 200 600 4 Milbank U7040 200 600 4 Murray BY120GK 185 600 4 Landis & GYR RS635-L6BH EZ1000-0-R4- SP Solar 175 600 4 Any Marwell Part # Continuous A Rating Voltage Rating # of Jaws Panels Tested Short Circuit Rating – 10,000 RMS Hypot Test - 6000V Indoor / Outdoor Rated NEMA 3R 65A Continuous Rated back feed (Solar Supply), 80 A Maximum ****All Tests conducted By UL Laboratories conforming to UL414**** UL Listed File # E142068 E142068 Physical Nominal Values Test Specific Gravity 1.26 ASTM D792 Melt Flow (300 Deg C/1.2 kg.) 12.0g/10 min ASTM D1238 Mechanical Tensile Modulus 480,000 psi ASTM D638 Tensile Strength @ Yield 9,400 psi ASTM D638 Flexural Modulus 490,000 psi ASTM D790 Flexural Strength @ Yield 14,500 psi ASTM D790 Impact Notched Izod Impact (73 Degrees F, 0.125 in) 2.50 ft-lb/in ASTM D256 Thermal DTUL @ 264 psi-un-annealed (.125 in) 288 Degrees F ASTM 648 UL Rating Flammability Rating V-0 @ 0.125” UL 94 RTI, Electrical 125 Degrees C UL 746B RTI, Mechanical with Impact 115 Degrees C UL 746B RTI , Mechanical without Impact 125 Degrees C UL746B Plastic Rating – UL Listed, 10% Fiberglass Reinforced Polycarbonate with UV Marwell Part # 1000-0R-Solar CANTEX INC. | 301 Commerce Street, Suite 2700, Fort Worth, TX 76102 | 817.215.7000 | www.cantexinc.com Junction Box PVC Junction Boxes Part Number Trade Size Description Carton Qty. Junction Box Base Cover Screws “A”“B”“C”“D”“E”“F”“G”“H”“J”“K”“A”“B”“C”“D” 51337051 4x4x2 Molded 10 2.000 2.150 5.375 4.400 4.400 4.000 4.000 .250 .125 .160 .240 .370 4.375 4.375 #8 x 1/2” 51337091 4x4x4 Molded 10 4.000 4.150 5.375 4.400 4.400 4.000 4.000 .250 .188 .160 .240 .700 4.375 4.375 #8 x 1/2” 51337071 4x4x6 Molded 10 6.000 6.150 5.375 4.400 4.400 4.000 4.000 .250 .188 .160 .240 .370 4.375 4.375 #8 x 1/2” 51337061 5x5x2 Molded 10 2.000 2.170 6.375 5.375 5.375 5.000 5.000 .250 .188 .170 .180 .267 5.375 5.375 #8 x 1/2” 51337101 6x6x4 Molded 10 4.000 4.200 7.375 6.438 6.438 6.000 6.000 .250 .188 .220 .180 .350 6.750 6.750 #8 x 1/2” 51337111 6x6x6 Molded 5 6.000 6.250 7.375 6.438 6.438 6.000 6.000 .250 .188 .220 .180 .350 6.750 6.750 #8 x 1/2” 51337121 8x8x4 Molded 5 4.000 4.250 9.375 8.625 8.625 8.000 8.000 .250 .188 .220 .180 .350 9.000 9.000 #10 x 3/4” 51331641 8x8x6 Molded 4 6.000 6.250 9.375 8.625 8.625 8.000 8.000 .250 .188 .220 .180 .350 9.000 9.000 #10 x 3/4” 51337081 8x8x7 Molded 4 7.000 7.250 9.375 8.625 8.625 8.000 8.000 .250 .188 .220 .180 .350 9.000 9.000 #10 x 3/4” 51337141 12x12x4 Molded 2 4.000 4.250 13.625 12.625 12.625 11.875 11.875 .250 .188 .220 .220 .437 13.000 13.000 #10 x 3/4” 51337131 12x12x6 Molded 2 6.000 6.250 13.750 12.625 12.625 11.875 11.875 .250 .188 .220 .220 .437 13.000 13.000 #10 x 3/4” *5133176 12x12x12 Fab 1 ------------------------------ **5133163 16x14x6 Molded 1 6.00 6.250 16.000 14.875 16.875 16.435 14.435 .220 .125 .220 .214 .500 17.125 17.125 #10 x 3/4” *5133167 18x18x6 Fab 1 ------------------------------ *5133165 24x18x8 Fab 1 ------------------------------ *5133161 24x18x12 Fab 1 ------------------------------ *5133177 24x24x6 Fab 1 ------------------------------ *5133166 24x24x8 Fab 1 ------------------------------ *5133173 36x24x8 Fab 1 ------------------------------ Dimensions are nominal * Not UL Listed - 4X NEMA Rating ** UL Listed with only a Type 1 NEMA Rating Fabricated Junction Box UL Catagory - QCUP UL File #E205935 Control #92CM 1. NEMA Ratings for Types, 1, 3, 3S, 4, 4X, 5, 6, and 6P Junction Boxes are designed to support electrical devices and fixtures. They also provide necessary protection for wires and terminals. • Material is Rigid PVC • Neoprene gasket with zinc plated steel screws • UL Listed, UL Marine Listed • Made in USA • Material is Rigid PVC • Neoprene gasket with zinc plated steel screws • Fully gasketed cover • Made in USA • See certifications below Molded Junction Box RAIL-FREE RACKING Utilizes EcoFasten Solar’s patented technology 3.0 www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 1 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 8,153,700 8,181,398 8,166,713 8,146,299 8,209,914 8,245,454 8,272,174 8,225,557 9,010,038 9,134,040 9,175,478 9,212,833 Rock-it syste m 3.0 Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are fast and easy to install, straightforward, secure and cost-effective. EcoFasten offers a wide variety of standard products as well as custom solutions, for a one-stop source for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry standards in- service in the snow guard and solar industries for over two decades. Features New and improved design Fastest, easiest to level system on the market Integrated electrical bonding SIMPLE- only 5 components North-South adjustability socket) Vertical adjustment of - syste m Co mponents* - Required syste m Co mponents* - optional Rock-It 3.0 Array Skirt End Caps (End Caps co me pre-installed on East end of skirt sections) Rock-It clip ss (Refer to pg. 7) Rock-It Slide 4” or 8" Rock-It 3.0 Mount Rock-It clip 2.0 (Refer to pg. 7) Rock-It 3.0 hybrid Mount (Refer to pg. 5) Ro ck - i t 3.0 A r r a y Skirt Rock-It 3.0 Coupling and Load bearing foot Level Nut Cap www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 2 Rock-it 3.0 Mount Assembly Note: Items 1-7 ship assembled 1.Rock-It 3.0 Shelf 2.Rock-It 3.0 MidClamp 3.Rock-It 4.0 Tie Plate 4.Set Pins 5. Flange Level Nut Mid 6. 6. B-FL SS-.313-18X1.25 7.Rock-It Pedestal 8.W-ET LOCK .3750 9. B-FL-SS-.313-18X.375 10. B-HX-SS-.375-16-3.5 11. Rock-It Z Nut Clip Rock-it slides are acceptable brackets for use with Rock-It 3.0 (sold separately) 1. Rock-It 3.0 Shelf Coupling 2. Rock-It 3.0 MidClamp 3. B-FL SS-.313-18X1.25 4. Bonding Pins 5. Rock-It Z Nut Clip 6. Load Bearing Foot Rock-it 3.0 COUPLING Assembly Note: Items 1-3 ship assembled www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 3 Rock-it 3.0 HYBRID Mount Asse mbly Note: Ite ms 1-9 ship asse mbled 1.Rock-It 3.0 Shelf Coupling 2.Rock-It 3.0 MidClamp 3.B-FL SS-.313-18X1.25 4.Bonding Pin 5.Rock-It Z Nut Clip 6.B-FL SS-.313-18X.375 7.W-ET LOCK .3750 8.Rock-It Pedestal 9.B-HX SS-.375-16X3 Rock-it clip ss Asse mbly Note: Discontinued 12/31/2017 - still approved 1.Stainless Steel Carriage Bolt - .313-18x.75 2.Rock-It Clip SS 3.Stainless Steel Flange nut .313-18 Rock-it clip 2.0 Asse mbly Note: Ite ms 1-3 ship asse mbled 1.Rock-It Clip 2.0 2.Stainless Steel Flange nut .313-18 3.Bolt .3125-18x1x1-S www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 6 grounding lug install Necessary Components: - One of the following ground lugs (or any UL 2703 compliant ground lug): ILSCO SGB-4 Ground Lug (UL 2703 - E354420 / UL 467 - E34440) ILSCO GBL-4DBT (UL 2703 - E354420 / UL 467 - E34440) ILSCO GBL-4DBTH (UL 2703 - E354420 / UL 467 - E34440) ILSCO GBL-4SS (UL 2703 - E354420 / UL 467 - E34440) Note: Drill and deburr hole in Ground Lug prior to installation 14 AWG - 4 AWG Copper Ground Wire* - 8- SS) - 8-32 Serrated Flange Nut (300 Series SS) - ratchets/sockets 1.Insert the flange bolt into the module ground hole. Place Star Washer over bolt. Place ground lug over the bolt and Star Washer, and turn to desired orientation. 2.Install Flange Nut. 3.Tighten Flange Nut/Bolt. 4.Place wire in Ground Lug channel and tighten set screw to complete assembly. Torque Values: 14-10 AWG= 20 in-lbs. 8 AWG= 25 in-lbs. 6-4 AWG= 35 in-lbs. *Wire should be sized in accordance with the National Electrical Code, NFPA 70, Section 690.45, and a minimum of Burndy CL50-1TN Ground Lug (UL 2703 - E3514343 / UL 467 - E9999) Installation: