Loading...
HomeMy WebLinkAbout_SOLR23-0883_Nazdan Permit PackageSignature of Licensed Preparer Nadzan Residence 2 Adria Circle Palm Desert, CA 92211 15.6 kw DC, 14.71 kw AC 39 REC400AA Pure 1 SE11400H-US SolarEdge Square D Shingle IronRidge 5/31/23 Size: Modules: Inverter: DC Dis.: AC Dis.: Roof: Racking: Date: Solar Central 72056 North Shore St. Suite B Thousand Palms, CA 92276 760-640-0000 CA License #1051362 C46 DWG# 1 Cover Sheet DWG# 2 Site Plan DWG# 3 Layout DWG# 4 Electrical Diagram DWG# 5 CEC Calculations DWG# 6 General Notes DWG# 7 System Labels Product Spec Sheets 15.6 kw Roof Mounted Photovoltaic Nadzan Residence 2 Adria Circle Palm Desert, CA 92211 39 REC 400 Watt Panels Drawing Number: 1 Type text here Signature of Licensed Preparer Nadzan Residence 2 Adria Circle Palm Desert, CA 92211 15.6 kw DC, 14.71 kw AC 39 REC400AA Pure 1 SE11400H-US SolarEdge Square D Shingle IronRidge 5/31/23 Size: Modules: Inverter: DC Dis.: AC Dis.: Roof: Racking: Date: Solar Central 72056 North Shore St. Suite B Thousand Palms, CA 92276 760-640-0000 CA License #1051362 C46 18" 18" Drawing Number: 2 Site Plan Driveway Main Service Panel AC Disconnect AC Disconnect (Inside Garage) Inverter (Inside Garage) New Receptacle (Inside Garage) Property Line Property Line Pool Pr o p e r t y L i n e Pr o p e r t y L i n e Adr i a C i r c l e Solar Modules Signature of Licensed Preparer Nadzan Residence 2 Adria Circle Palm Desert, CA 92211 15.6 kw DC, 14.71 kw AC 39 REC400AA Pure 1 SE11400H-US SolarEdge Square D Shingle IronRidge 5/31/23 Size: Modules: Inverter: DC Dis.: AC Dis.: Roof: Racking: Date: Solar Central 72056 North Shore St. Suite B Thousand Palms, CA 92276 760-640-0000 CA License #1051362 C46 2'-0" Drawing Number: 3 Layout Max spacing on solar roof attachments = 72" IronRidge RailShingle Under layment 5 16" X 31 2" Lag Screw with 21 2" minimum embedment Weather sealant in pilot hole 2" X 4" Rafter 24" O.C. Solar Module IronRidge Flashvue IronRidge FlashvueRafterSupport Rail Solar Module Signature of Licensed Preparer Nadzan Residence 2 Adria Circle Palm Desert, CA 92211 15.6 kw DC, 14.71 kw AC 39 REC400AA Pure 1 SE11400H-US SolarEdge Square D Shingle IronRidge 5/31/23 Size: Modules: Inverter: DC Dis.: AC Dis.: Roof: Racking: Date: Solar Central 72056 North Shore St. Suite B Thousand Palms, CA 92276 760-640-0000 CA License #1051362 C46 Integrated DC Disconnect enclosure attached to inverter #6 AWG wire provided by manufacturer + - Inverter-Integrated DC Disconnect/ String Combiner L1 L2 N G G Inverter 3 G + ++ - --- - + + +-+-+-String of 14 PV modules with Optimizers ........ 1 +-+-+- +-+-+-String of 13 PV modules with Optimizers ........ 1 +-+-+- INVERTER RATINGS 3 SOLAR OPTIMIZER RATINGS 2 Note: SolarEdge inverter meets CEC 690.12 Rapid Shutdown Requirements SolarEdge Optimizers2 Racking Integrated Grounding System Bonds Solar Panel Frames to Support Rail If Existing Earth Ground is not accessible, an irreversible splice will be made to the Grounding Electrode Conductor To Utility L1 L2 G N N Typical Neutral-to-ground Connection point Utility-Supplied 240 VAC KWH Meter System Summary Service Main: 200 Amps Main OCPD Rating: 175 Amps Service Voltage: 240 Volts PV System Size: 15.6 kW DC Max # of Modules in Series: 1 Modules Max # of Optimizers in Series: 14 Optimizers # of Strings: 3 Strings Inverter BackFeed Breaker: 60 Amps PV System Azimuth: 90°, 180° PV System Tilt: 18° L2L1 G THWN-2 6 - #10 AWG 1 - #8 AWG EGC 3 4" EMT Support Rail AC Line 2 AC Line 1 Bare Copper DC Negative DC Positive Legend AC Neutral Equip. Ground PV MODULE RATINGS @ STC 1 AC DISCONNECT RATINGS MANUFACTURER= SQUARE D MODEL= DU222RB DISCONNECT AMP RATING= 60 A DISCONNECT VOLT RATING= 240 V 4 +-+-+-String of 12 PV modules with Optimizers ........ 1 +-+-+- #6 Bare Copper Ground under array where exposed. Inside junction box it will be permanently bonded to #8 AWG Stranded Ground which will run through EMT conduit with conductors. + -- + - + MANUFACTURER= SOLAREDGE OPTIMIZER MODEL= S440 MAXIMUM INPUT VOLTAGE= 60 V MAXIMUM INPUT ISC= 14.5 A MAXIMUM OUTPUT VOLTAGE= 60 V MAXIMUM OUTPUT CURRENT= 15 A MAXIMUM STRING= 25 OPTIMIZERS MAXIMUM SYSTEM VOLTAGE= 1000 V 175 AMP 2 pole Main Breaker 15 AMP 2 pole breaker L2 L1 G L2 L1 AC Disconnect 4 L2 L1 G L2 L1 AC Disconnect (Inside Garage) 4 THWN-2 3 - #6 AWG 1 - #8 AWG EGC 3 4" EMT 60 AMP 2 pole breaker New Receptacle THWN-2 PV Conductors 3 - #6 AWG 1 - #8 AWG EGC Receptacle Conductors 3 - #12 AWG 1 - #12 AWG 1" EMT MODULE MANUFACTURER= REC MODULE MODEL= REC400AA PURE OPEN-CIRCUIT VOLTAGE= 48.8 V OPERATING VOLTAGE= 42.1 V MAX SYSTEM VOLTAGE= 1000 V OPERATING CURRENT= 9.51 A SHORT-CIRCUIT CURRENT= 10.10 A MAX SERIES FUSE(OCPD)= 25 A MAXIMUM POWER (@25°C)= 400 W MANUFACTURER= SOLAREDGE INVERTER MODEL= SE11400H-US NOMINAL DC VOLTAGE= 400 V MAX POWER= 11,400 W NOMINAL AC VOLTAGE= 240 V MAX AC CURRENT= 47.5 A MAX OCPD RATING= 60 A FREQUENCY= 60 HZ Existing Main Service Panel 200 amp busbar 175 amp main breaker 60 amp solar breaker 200 x 120% = 240 amps 175 + 60 = 235 amps Permanent placard shall be placed at main service breaker stating "MAIN SERVICE BREAKER HAS BEEN DOWNSIZED TO 175 AMPS. NO UPSIZING IS PERMITTED." Main Service Panel is fed from bottom of the busbar. Solar Inverter breaker will be located at the opposite end of the busbar per NEC 705.12(B)(3)(2) Drawing Number: 4 Electrical Diagram Signature of Licensed Preparer Nadzan Residence 2 Adria Circle Palm Desert, CA 92211 15.6 kw DC, 14.71 kw AC 39 REC400AA Pure 1 SE11400H-US SolarEdge Square D Shingle IronRidge 5/31/23 Size: Modules: Inverter: DC Dis.: AC Dis.: Roof: Racking: Date: Solar Central 72056 North Shore St. Suite B Thousand Palms, CA 92276 760-640-0000 CA License #1051362 C46 System Description Enclosed documents describe requirements for a new Photovoltaic (PV) system. PV equipment location shall be coordinated with owner's representative. All wires to transition boxes shall be routed within metallic cable tray system. Length, gauge and type of wire is indicated on "Electrical Diagram" drawing. Output from grid-tied inverters may be combined in an AC combiner panel then interconnected with the grid power (in concordance with CEC 690.59). If used, the AC combiner will be shown on the "Electrical Diagram" drawing. The complete PV system described here shall be installed and commissioned such that it operates automatically as follows: 1. When grid power is present, solar power runs loads onsite during the day. 2. When grid power fails, the PV system shall automatically disconnect from the grid. 3. The PV system shall automatically resume supplying power to the grid when the proper voltage and frequency (As mandated by the IEEE standards) is restored and there is sufficient sunlight. Inverter Input Circuit: SolarEdge Optimizer S440 Optimizer Max Continuous Current = 15 A 125% of optimizer max continuous output circuit = 125% x 15 = 18.75 A Inverter Input Circuit wiring from SolarEdge Optimizers under PV modules to inverter = (1 set) #10 THWN-2, 90 degrees C rated Conductors will be more than 7/8" above the roof surface. Temperature correction factor for 40 degree C = 0.91 Correction factor for 6 current-carrying conductors = 0.8 Corrected ampacity = 40 A x 0.91 x 0.8 = 29.12 A > 18.75 A DC Voltage REC400AA Pure PV Module Voc = 48.8 VDC STC PV Module Vpm = 42.1 VDC STC Maximum number of PV Modules per string = 1 Nominal Maximum Power Voltage = 42.1 x 1 = 42.1 V Correction factor per CEC 690.7 (A) for -5 degree C = 1.12 x (PV module Voc at 25 degree C) = 54.66 V Maximum Open Circuit Voltage = 1 x 54.66 = 54.66 V PV Source Circuit PV module Isc = 10.10 A PV module Imp = 9.51 A # of modules in parallel per source circuit = 1 Max Isc = 1 x 10.10 A x 1.25 = 12.63 A Inverter Output Circuit: SolarEdge-SE11400H-US Inverter Max Continuous Current = 47.5 A Inverter output circuit over current protection = 60 A breaker 125% of inverter max continuous output circuit = 125% x 47.5 = 59.38 A Output circuit continuous current = 59.38 A < 60 A Inverter output wiring to dedicated inverter circuit breaker = (1 set) #6 THWN-2, 90 degrees C rated Temperature correction factor for 40 degrees C ambient = 0.91 Corrected ampacity = 75 A x 0.91 = 68.25 A > 60 A Drawing Number: 5 Electrical Calculations Signature of Licensed Preparer Nadzan Residence 2 Adria Circle Palm Desert, CA 92211 15.6 kw DC, 14.71 kw AC 39 REC400AA Pure 1 SE11400H-US SolarEdge Square D Shingle IronRidge 5/31/23 Size: Modules: Inverter: DC Dis.: AC Dis.: Roof: Racking: Date: Solar Central 72056 North Shore St. Suite B Thousand Palms, CA 92276 760-640-0000 CA License #1051362 C46 1.All Electrical work shall be in accordance with the 2022 Editions of the California Building Code, California Electrical Code (CEC) , California Plumbing Code, California Mechanical Code, California Fire Code and the California Energy Code, local municipal code, and local fire district regulations. 2. Applications for which no permit is issued within 180 days following the date of application shall automatically expire. 3. Every permit issued shall become invalid unless work authorized is commenced within 180 days, a successful inspection is not obtained within 180 days, or if work is suspended or abandon for a period of 180 days. 4. All equipment shall be listed and labeled per recognized electrical testing laboratory and installed per the listing requirements and the manufacturer's instructions. 5. All inverters shall be UL 1741 compliant and shall be inspected by local utility before commissioning, testing, and operation of the system. 6. All outdoor equipment shall be minimum NEMA 3R, including outdoor transition boxes, combiner boxes, and switches. 7. All equipment shall be properly grounded per the requirements of CEC ART. 250, 690. 8. All circuits shall have overcurrent protection as required by CEC ART.690.9 (A). 9. Due to the fact that PV modules are energized whenever they are exposed to light, PV contractors shall enable the array during installation and service by short circuiting, opening circuiting, or covering the array with an opaque covering. 10. Photovoltaic system shall back feed the distribution system on site per the requirements of CEC ART. 705. All back feed breakers shall be identified as such. 11. Fall arrest protection per OSHA requirements shall be provided for all roof work. 12. All conductors and termination shall be rated for 75 degree C minimum. 13. CEC ART. 705.10 A permanent plaque or directory denoting the location of all electric power source disconnecting means on or in the premises shall be provided at each service equipment location and at the location(s) of the system disconnect(s) for all electric power production sources capable of being interconnected. The marking shall comply with CEC ART. 110.21 (B). 14. CEC ART. 690.13 (B) each DC disconnect shall be labeled with: "PV System Disconnect." Label shall be 1" x 4" minimum with UV resistant lettering per local municipal code. 15. CEC ART. 690.53 A placard, UV resistant, and lettering per local municipal code, shall be provided beside the dc disconnect location with the following text: Maximum voltage = XXX VOLTS, Maximum Short circuit current = XXX AMPS 16. CEC ART. 690.13 (B) Each AC disconnect shall be labeled with: "PV System Disconnect." Label shall be 1" x 4" minimum with UV resistant lettering per local municipal code. 17. CEC ART. 690.13 (B) Each disconnect where both line and load sides may be energized in the open positions shall also be labeled with: "Warning! - Electrical shock hazard - Do not touch terminals on both line and load side may be energized in the open position". Label shall be 1" x 4" minimum with UV resistant lettering per local municipal code. 18. DC disconnect at the inverter shall be readily accessible after the installation is complete per CEC ART.690.13 (A). 19. Contractor to provide ground fault protection for photovoltaic arrays per CEC ART. 690.41 (B) 20. Contractor to provide Arc fault protection for all photovoltaic systems operating at 80 volts DC or greater per CEC ART. 690.11. 21. Where more than one nominal voltage system exists, the different Systems shall be identified by phase and system per CEC ART. 215.12 (C). 22. Provide an accessible disconnect device that is lockable in open position and is located within 10' - 0" of the meter per local electrical utility regulations. 23. Photovoltaic source currents must be rated at both 125% of the parallel module and at a continuous load of another 125% for a total of 156% of the load. 24. Installation of PV panel arrays should resist sliding and pop-up resulting from seismic events and should comply with CBC section 1613A and ASCE standard 7-16, Chapter 13. 25. Design indicates use of copper wire for DC circuits, use of aluminum wires is not allowed. 26. It is recommend to install the PV array such that general shading of the PV modules between 9:00 am - 3:00 pm solar is minimized and localized shading due to plumbing or air vents is minimized. 27. PV system installer will be responsible for furnishing and installation of all related equipment, cables, additional conduits, boxes wireways and other accessories necessary for complete and operational photovoltaic system. 28. PV system contractor shall coordinate all the work with the engineer, the construction manager and all other contractors to insure that PV system is installed as specified in these drawings. 29. Drawings in general are diagrammatic and indicate general arrangement of the equipment and work included. The intention of the drawings is to indicate size, capacity, approximate location and general relationship, but not exact detail or physical placement. 30. Field verify exact AC rating required of the main switchboard from local utility company. 31. Notify serving utility before activation of pv system. 32. Working clearances around existing electrical equipment as well as the new electrical equipment will be maintained in accordance with CEC 110.26. 33. Per section R314 and R315 of CRC 2019, it is required that Smoke alarm and Carbon Monoxide Detectors are retrofitted into existing dwelling for a permit with repairs or additions exceeding $1000. 34. Wiring methods will be according to CEC ART. 690.31. All raceways and cables, fittings specifically intended and identified for use on photovoltaic systems. Direct current and alternating currents shall be separated by barriers to meet code requirements. 35. Circuits over 150 volts to ground in one and two family dwellings, live parts in photovoltaic source circuits and photovoltaic output circuits over 150 volts to ground shall not be accessible to other than qualified persons while energized. 36. Point of connection CEC ART. 705.12 (B) Inverter Output Connection in a panelboard shall be positioned at the opposite (load) end from the input feeder location or main circuit location. A permanent label shall be applied to the distribution equipment with the following or equivalent markings. "WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE" 37. Conduit wiring systems, and raceways for photovoltaic circuits shall be located as close as possible to the ridge or hip or valley and from the hip or valley as directly as possible to an outside wall to reduce trip hazards and maximize ventilation opportunities. Conduit runs between sub arrays and to DC combiner boxes shall be installed in a manner that minimizes the total amount of conduit on the roof by taking the shortest path from the array to the DC combiner box. The DC combiner boxes shall be located such that conduit runs are minimized in the pathways between arrays. DC wiring shall be installed in metallic conduit or raceways when located within enclosed spaces in a building. Conduit shall run along the bottom of load bearing members. 38. Electric utility company servicing building shall be notified prior to operation of the PV system. Drawing Number: 6 General Notes Signature of Licensed Preparer Nadzan Residence 2 Adria Circle Palm Desert, CA 92211 15.6 kw DC, 14.71 kw AC 39 REC400AA Pure 1 SE11400H-US SolarEdge Square D Shingle IronRidge 5/31/23 Size: Modules: Inverter: DC Dis.: AC Dis.: Roof: Racking: Date: Solar Central 72056 North Shore St. Suite B Thousand Palms, CA 92276 760-640-0000 CA License #1051362 C46 Meter Main Service Panel AC Disconnect Inverter DC Disconnect ON OFF NOTE: A directory placard showing the locations of Main Service Disconnect, Photovoltaic Disconnect(s) and Solar Array(s) will be installed. DC DISCONNECT Typical Typical Typical Note: Materials used for all marking shall be reflective, weather resistant and suitable for the environment. All letters shall be a minimum height of 3/8", capitalized and white on a red background. On Ext. and Int. Conduit Every 10 Feet and within 1' of turns and within 1' above/or below penetrations and all Disconnects, Combiners and Junction Boxes. If Required AC DISCONNECT Typical PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING CURRENT 47.5 AMPS OPERATING VOLTAGE 240 VOLTS WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. IF A GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Typical WARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE Typical Typical Typical at Backfed Solar Breaker WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE DC PHOTOVOLTAIC POWER SOURCE MAX SYSTEM VOLTAGE = 480 VOLTS MAX SHORT CIRCUIT CURRENT = 45 AMPS WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC MODULES PRODUCE DC VOLTAGE WHENEVER THEY ARE EXPOSED TO SUNLIGHT Typical WARNING: PHOTOVOLTAIC POWER SOURCE WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. Junction Box If Required Typical SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS Typical Drawing Number: 7 System Labels POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CAUTION: PO O L DR I V E W A Y PV SYSTEM DISCONNECT FOR UTILITY OPERATION SERVICE POINT AND UTILITY METERING SOLAR PHOTOVOLTAIC ON ROOF Type text here rec Alph ® pure Black Series Product Specifications experience performance wp400 20.1 w ft2 ELIGIBLE LEAD-FREE rohs cOMPLIANT www.recgroup.com Re f: PM- Re v- A Founded in , REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, a ordable innovation, and a low carbon footprint in the solar materials and solar panels it manufac tures. Headquartered in Nor way with operational headquar ters in Singapore, REC also has regional hubs in Nor th America, Europe, and A sia-Pacific. GR GR GR GR GR 1821±2.5 [71.7±0.1] 901 [35.5]460 [18.1] 97 5 ± 2 . 5 [ 3 8 . 4 ± 0 . 1 ] 1100 [43.3] 1200 [47.2] 30 [1.2] 22.5 [0.9] 671 ±3 [26.4 ±0.12] 11±0.2 [0.43±0.01] 6. 6 ± 0 . 2 [ 0 . 2 6 ± 0 . 0 1 ] 20.5±0.5 [0.8±0.02] 6.0±0.2 [0.24±0.01] 28 [1.1] 10 1 6 ± 2 . 5 [ 4 0 ± 0 . 1 ] 17 [ 0 . 7 ] 45 [1.8] Measurements in mm [in] Sp e c i fic at ion s subj ect to cha n ge w it hout no ti c e. CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MA XIMUM RATINGS Irradiance (W/m) Typical low irradiance per formance of module at STC: Nominal Module Operating Temperature:°C (±°C) Temperature coec ient of PMAX:/°C Temperature coec ient of VOC:°C Temperature coec ient of ISC:°C *The temperature coe cients stated are linear values Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All kW kW Product Warranty (yrs) Power Warranty (yrs) Labor Warranty (yrs) Power in Year Annual Degradation Power in Year See warranty documents for details. Conditions apply ELECTRICAL DATA Product Code*: RECxxxA A Pure Black Power Output - PMA X (Wp) /+/+/+/+/+ Nominal Power Voltage - VMPP (V) Nominal Power Current - IMPP (A) Open Circuit Voltage - VOC (V) Short Circuit Current - ISC (A) Panel Ec iency () Power Output - PMA X (Wp) Nominal Power Voltage - VMPP (V) Nominal Power Current - IMPP (A) Open Circuit Voltage - VOC (V) Short Circuit Current - ISC (A) Values at standard test conditions (STC: air mass AM , irradiance W/m ), temperature °F (C), based on a production spread with a tolerance of PMAX, VOC & ISC ±, irradiance W/m, temperature °F (°C), windspeed m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: half-cut REC heterojunction cells with lead-free, gapless technology strings of cells in series Glass:in ( mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) Junction box:-part, bypass diodes, rated in accordance with IEC Connectors: Stäubli ( mm ) in accordance with IEC only when connected Cable: AWG ( mm PV wire, + in ( + m) accordance with EN Dimensions: x x in () Weight: lbs (kg ) Origin:Made in Singapore STC NMOT 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 Operational temperature:+ ... + Maximum system voltage : Maximum test load (front): + Pa ( )* Maximum test load (rear):- Pa ( )* Max series fuse rating: A Max reverse current: A * See installation manual for mounting instructions. Design load = Test load / safety factor) Product SPECIFICATIONS REC ALPHA PURE BLACK SERIEs > Product SPECIFICATIONS IEC Pending ISO :, ISO :, OHSAS : solaredge.com Power Optimizer For Residential Installations S440 / S500 / S500B / S650B Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules PO W E R O P T I M I Z E R 25 YEAR WARRANTY * Functionality subject to inverter model and firmware version © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: February 16, 2023 DS-000091-ENG. Subject to change without notice. Power Optimizer For Residential Installations S440 / S500 / S500B / S650B S440 S500 S500B S650B UNIT INPUT Rated Input DC Power(1) 440 500 650 W Absolute Maximum Input Voltage (Voc) 60 125 85 Vdc MPPT Operating Range 8 – 60 12.5 – 105 12.5 - 85 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 165 x 45 mm Weight 720 790 gr Input Connector MC4(3) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(4) -40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 – 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity – CE. (3) For other connector types please contact SolarEdge. (4) Power de-rating is applied for ambient temperatures above +85°C for S440 and S500, and for ambient temperatures above +75°C for S500B. Refer to the Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(5) SolarEdge Home Wave Inverter Single Phase SolarEdge Home Short String Inverter Three Phase Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B, S650B 6 8 14 Maximum String Length (Power Optimizers) 25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(6) See(6) 13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note: Single String Design Guidelines. S440, S500 (Flat Bracket) S500B, S650B (Bent Bracket) IN V E R T E R S solaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEARWARRANTY MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Single Phase Inverter with HD-Wave Technology for North America MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3)Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box(4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice. Roof Mount System Strongest Rails Longer spans between attachments, fewer roof penetrations. PE Certified Pre-stamped engineering letters available in most states. Simple Assembly Versatile and adjustable components simplify any array design. Design Software Online tool generates a complete bill of materials in minutes. Integrated Grounding UL 2703 system eliminates separate module grounding components. 20 Year Warranty Twice the protection offered by competitors. Built for solar’s toughest roofs. Anchored by the strongest rails in solar, the IronRidge Roof Mount System provides the durability and versatility to handle virtually any residential or commercial rooftop. The unique curved profile of the XRS Rail increases its strength while also giving it an attractive look, making it very customer-friendly. In addition, IronRidge Rails are certified for integrated grounding, which eliminates separate module grounding components and procedures, making it very installer-friendly. Datasheet Online Software The IronRidge Design Assistant helps you go from rough layout to fully engineered system. For free. Go to ironridge.com/rm © 2013 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Rails Standrard Rails (XRS)Light Rails (XRL)Rail Splices Curved rails increase spanning capabilities and aesthetics. • Available in clear and black anod. • Multiple sizes between 12’ and 18’ • Made of corrosion resistant alum. Attachments Flashings Adjustable L-Feet Tilt Leg Kits Lightweight rails reduce cost for lighter load conditions. • Available in clear and black anod. • Multiple sizes between 12’ and 18’ • Made of corrosion resistant alum. Internal splices seamlessly connect rails, allowing easy L-foot installation. • Different versions for XRS and XRL • Includes self-tapping screws • Available with grounding straps FlashFoot™ is an all-in-one mounting product for composition shingle roofs. • Integrated L-Foot and hardware • Certified compliant with IBC & IRC • PE certified with IronRidge Rails Slotted L-feet provide adaptable attachment to standoffs and flashings. • Available in clear and black anod. • Works with XRS and XRL rails • Compatible with third-party parts Fixed and adjustable tilt legs allow adjustment in all three axes. • Attaches directly to XRS and XRL • Ships with all required hardware • Multiple sizes for 5-45 deg. tilts Clamps & Accessories End Clamps Secure modules to the end of the rails. • Clear and black anod. • Sizes from 1.22” to 2.3” • Optional bottom clamps Mid Clamps Fasten modules in the middle of the rails. • Clear and black anod. • T-bolt or hex nut designs • Grounding clamp offered End Caps Provide a finished look for rails. • Keeps out debris • Black polycarbonate • UV protected Wire Clips Organize both DC and AC wiring along the rails. • Attaches to both rails • Supports ten 5mm wires • UV protected MacBook Pro Available with Integrated Grounding IronRidge offers UL 2703 certified components that automatically bond modules and rails to ground. Go to ironridge.com/ig Datasheet Tech Brief Class A Fire Rating Background All roofing products are tested and classified for their ability to resist fire. Recently, these fire resistance standards were expanded to include solar equipment as part of the roof system. Specifically, this requires the modules, mounting hardware and roof covering to be tested together as a system to ensure they achieve the same fire rating as the original roof covering. Adoption of these new requirements will begin in California in 2015 and extend to the rest of the country in 2016. IronRidge Certification In August 2014, IronRidge was the first company to receive a Class A Fire Rating— the highest possible rating—from Intertek Group plc., a Nationally Recognized Testing Laboratory. IronRidge Roof Mount products were tested on flat and sloped roofs in accordance with the new UL 1703 & UL 2703 test standards. The testing evaluated the system’s ability to resist flame spread, burning material and structural damage to the roof. Refer to the table below to determine the requirements for achieving a Class A Fire Rating on your next project. Test Setup Solar Modules Solar modules are given a Type classification based on their materials and construction. Mounting System Mounting is tested as part of a system that includes type-tested modules and fire-rated roof covering. Roof Covering Roof covering products are given a Fire Class Rating of A, B or C based on their tested fire resistance. A burning wooden block is placed on module as a fan blows at 12 mph. Flame cannot be seen on underside of roof within 90 minutes. Burning Brand Test Flame at southern edge of roof is aimed up the roof as a fan blows at 12 mph. The flame cannot spread 6 feet or more in 10 minutes. Spread of Flame Test Fire Testing Process Roof Slope Mount Module Fire Rating* Steep Slope (≥ 9.5 degrees) Flush Type 1, 2, & 3 Class A Tilt Type 1 & 2 Class A Low Slope (< 9.5 degrees) Flush Type 1, 2, & 3 Class A Tilt Type 1, 2, & 3 Class A *Class A rated PV systems can be installed on Class A, B, and C roofs. Tech Brief © 2015 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.12 More Resources Fire Rating Certificate Visit our website to download the official UL 2703 certification document. Go to IronRidge.com Engineering Certification Letters We offer complete engineering resources and pre-stamped certification letters. Go to IronRidge.com Frequently Asked Questions What is a “module type”? The new UL1703 standard introduces the concept of a PV module type, based on 4 construction parameters and 2 fire performance parameters. The purpose of this classification is to certify mounting systems without needing to test it with every module. What roofing materials are covered? All fire rated roofing materials are covered within this certification including composition shingle, clay and cement tile, metal, and membrane roofs. What if I have a Class C roof, but the jurisdiction now requires Class A or B? Generally, older roofs will typically be “grandfathered in”, and will not require re-roofing. However, if 50% or more of the roofing material is replaced for the solar installation the code requirement will be enforced. Where is the new fire rating requirement code listed? 2012 IBC: 1509.7.2 Fire classification. Rooftop mounted photovoltaic systems shall have the same fire classification as the roof assembly required by Section 1505. Where is a Class A Fire Rating required? The general requirement for roofing systems in the IBC refers to a Class C fire rating. Class A or B is required for areas such as Wildland Urban Interface areas (WUI) and for very high fire severity areas. Many of these areas are found throughout the western United States. California has the most Class A and B roof fire rating requirements, due to wild fire concerns. Are standard mid clamps covered? Mid clamps and end clamps are considered part of the PV “system”, and are covered in the certification. What attachments and flashings are deemed compatible with Class A? Attachments and their respective flashings are not constituents of the rating at this time. All code-compliant flashing methods are acceptable from a fire rating standpoint. What mounting height is acceptable? UL fire testing was performed with a gap of 5”, which is considered worst case in the standard. Therefore, the rating is applicable to any module to roof gap. Am I required to install skirting to meet the fire code? No, IronRidge achieved a Class A fire rating without any additional racking components. What determines Fire Classification? Fire Classification refers to a fire-resistance rating system for roof covering materials based on their ability to withstand fire exposure. Class A - effective against severe fire exposure Class B - effective against moderate fire exposure Class C - effective against light fire exposure What if the roof covering is not Class A rated? The IronRidge Class A rating will not diminish the fire rating of the roof, whether Class A, B, or C. What tilts is the tilt mount system fire rated for? The tilt mount system is rated for 1 degrees and up and any roof to module gap, or mounting height. Tech Brief Moving Flashing Forward We set out to design a flashing that checked all the boxes: fully waterproof, fast and easy to install correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. The optimized flashing design features a large viewport, for easy alignment with the pilot hole. And the GripCap and GripCap+ sit snugly in place, so the lag can be driven single-handedly. FlashVue™ GripCap & GripCap+ The 360º capable GripCap (2.74” tall) and GripCap+ (3.74” tall) can be placed in any orientation, and provide a “friction-fit” for easy installs. Push snug into the viewport, without worrying it will roll away or rotate while driving the lag. Three-Tier Water Seal, Reimagined FlashVue’s seal architecture utilizes three layers of protection. The viewport is elevated 0.30”, and provides a “friction-fit” for the GripCap. The GripCap fully covers the viewport while a sealing washer adds another layer of protection. And an EPDM washer and lag bolt “seal the deal” in the stack. Large Viewport in Flashing The large viewport makes it easy to align the flashing with the pilot hole, and drive the lag centered into the rafter. The elevated rim not only provides a sturdy dock for the GripCap or GripCap+, but increases water-shedding capabilities. ⌀ 0.75” Triple Certified to Protect the Roof™ UL 2703, 441 (27) TAS 100(A)-95 © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Tech Brief Solve Roof Undulations See Your Pilot Holes Also Available: GripCap+ We know roofs are not always perfectly flat. GripCap+ can help when undulations get in the way. Large Viewport in Flashing FlashVue makes pilot holes highly visible, like never before. No more tedious guesswork on hot roofs. Trusted Strength & Certification Attachment Loading FlashVue has been tested and rated to support 1161 (lbs) of uplift and 353 (lbs) of lateral load. Structural Certification Designed and certified for compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Passed both the UL 441 Section 27 “Rain Test” and TAS 100-95 “Wind Driven Rain Test” by Intertek. UL 2703 Listed System Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info.     Cut Sheet FlashVue v1.0 1 2 3 4 .61 7/16" Head 4.25 .26 5/16 THD 1) BOLT, LAG 5/16 x 4.25" FLASHVUE ITEM NO DESCRIPTION QTY IN KIT 1 BOLT, LAG 5/16 X 4.25"1 2 WASHER, EPDM BACKED 1 3 FM FLASHING, MILL OR BLACK 1 4 GRIP CAP, MILL OR BLACK 1 PART NUMBER DESCRIPTION FV-01-M1 FLASHING, FLASHFOOT, MILL FV-01-B1 FLASHING, FLASHFOOT, BLACK Property Value Material 300 Series Stainless Steel Finish Clear Cut Sheet v1.0