Loading...
HomeMy WebLinkAboutRRAD22-0163 PLAN.pdf GENERAL NOTES SITE PLAN NOTES WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE NOTE:Prior to final inspection the licensed contra or, UNDERGROUND SERVICE ALERT APPROVED CONSTRUCTION DOCUMENTS,AND ANY CHANGES architect or engineer in responsible charge of the overall MADE DURING CONSTRUCTION THAT ARE NOT IN COMPLIANCE constriction must provide to the building department official r I + �� - - .p" +^♦ 1.- ALL WORK,MATERIALS AND METHODS SHALL BE IN CONFORMANCE WARNING:PLANT MATERIAL LISTED MAY OR MAY NOT HAVE T■�' WITH THE APPROVED CONSTRUCTION DOCUMENTS SHALL BE written verification that all app cable provisions from the „� - •I � - k.• -,'v J WITH THE 2019 CBC CODES,2019 CPC,2019 CMC AND 2019 CEC CODE BEEN APPROVED BY THE AGRICULTURAL COMMISSIONER'S DICTA „� RESUBMITTED FOR APPROVAL AS AN AMENDED SET OF Green Building Standards Code have been implemented as EDITIONS.ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL OFFICE. 1, , CONSTRUCTION DOCUMENTS.CRC R106.4. part of the construction.CGC 102.3 AGENCIES HAVING JURISDICTION AT THE PROJECT LOCATION. LANDSCAPED AREAS INDICATED SHALL BE PROVIDED W/FULL 2.- THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL COVERAGE AUTOMATIC IRRIGATION SYSTEM W/AN APPROVED DIMENSIONS AND EXISTING CONDITIONS THEREON BEFORE BACK FLOW DEVICE. -Iri COMMENCING WORK.REPORT ANY DISCREPANCIES AND/OR POTENTIAL TEMPORARY TOILETS SHALL BE PROVIDED BY THE GENERAL PROBLEMS TO THE ARCHITECT PRIOR TO PROCEEDING WITH AFFECTED CONTRACTOR FOR ALL TRADES UNTIL THE COMPLETION OF ' Know whars below N woRK WORK. Call 811111110111 you dig. \ �• 3.- CONTRACTORS ARE RESPONSIBLE FOR ALL WORK REGARDLESS OF THE ALL TRADES SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR RUBBISH CAUSED LOCATION OF THE INFORMATION OF THE DOCUMENTS. BY THE WORK. TWO WORKING DAYS BEFORE YOU DIGS 4.- CONTRACTOR SHALL CONFIRM THAT PROPER FINISH GRADE ELEVATIONS - - HAVE BEEN PROVIDED AT THE PERIMETER OF THE BUILDING AREAS, NO UTILITY TRENCHES PARALLEL TO A FOOTING AND DEEPER THAN 18"SHALL BE LOCATED WITHIN A DISTANCE OF 4'-0"OF T o��•�y.,/GN�/•���(�/" REFER TO BUILDING AND ADJOINING AREAS,REFER TO BUILDING PLANS. A BUILDING FOOTING. q "� f 11 ` {.��Y .� r --"`-�"'�"�'��' REPORT ANY DISCREPANCIES TO THE DESIGNER PRIOR TO PROCEEDING � � WITH ROUGH GRADING. UTILITY TRENCHES PERPENDICULAR IS A FOOTING SHALL BE A MINIMUM OF 4'-0"DEEP AND THE DISTURBED SOIL SHALL BE � � � -- VWTH 5.- PROVIDE PIPE GUARDS AT ALL ABOVE GROUND UTILITY EQUIPMENT AS COMPACTED WITHIN A 4'-0"DISTANCE OF ANY FOOTING OR DICTATED BY GOVERNING AGENCIES. UNDER A CONCRETE SLAB. GOME7 I I I I/�AI 6.- PROVIDE PEDESTRIAN OR VEHICULAR PROTECTION BARRICADES ALL PROPERTY LINES,EASEMENTS AND BUILDINGS BOTH VICINITY MAP v�olV LI.I.W/'�� TEMPORARY GUARD RAILS,AND/OR CANOPIES AS REQUIRED BY THE EXISTING AND PROPOSED,ARE SHOWN ON THIS SITE PLAN. NOTT caE /ICC/V7/ITe� LOCAL AGENCIES OR AS NECESSARY FOR PEDESTRIAN AND VEHICULAR {; ,` A&SI rEI"M SAFETY. ' +• i�cNORTH 7.- THE GENERAL CONTRACTOR IS SLOLELY RESPONSIBLE FOR ��--------- DRAFTING • DESIGN • LAND PLANNING COORDINATION AMONG HIS VARIOUS SUBCONTRACTORS. CONSTRUCTION OBSERVATION /: l�A�p C IJ' 8.- IN THE EVENT OF DISCREPANCIES BETWEEN ANY DRAWINGS AND/OR 1. STRUCTURAL CONSTRUCTION OBSERVATION SHALL BE EXISTING DEPARTMENT OF BUILDING AND SAFETY PRINCIPAL DESIGN SPECIFICATIONS,THE MORE COSTLY OR MORE RESTRICTIVE CONDITIONS BACKYARD PROVIDED BY THE ARCHITECT/ENGINEER OF RECORD. CURRENT ADOPTED MODEL CODES: 75-178 GERALD FORD DR.,STE.BI SHALL BE DEEMED THE CONTRACT REQUIREMENT,UNLESS OTHERWISE LANDSCAPING 2119GAJJFCINA RESILENBALGODE: Based on the 2018 International Residential Code PALM DESERT,CA.92211 STATED IN WRITING,FROM THE DESIGNER. 2. EPDXY ATION UPLIFT SITUATIONS EPDXY REQUIRES OBSERVATION OF LIC.DEPUTY INSPECTOR 2119CA1JFCIMM0-NNI A-CE: Based on the 2018 National Electrical Code CEL EMAIL- 5luian@5 esigngrou.com 00 9.- GENERAL CONTRACTOR SHALL COORDINATE ALL UNDERGROUND 2719GNJFCRNAMO-NIJCPLCCCf: Based on the 2018 Uniform Mechanical Code EMAIL-gluian@gladesigngroup.com WITH THE PLUMBING,ELECTRICAL, GAS,TELEPHONE,AND CABLE 2919CALIFCItNAPLLNUNGOXE: Based on the 2018 Uniform Plumbing Code 9 I gngroup.com TV DRAWINGS. 2119CAJJFCTdJARRE CGCE: Based on the 2018 International Fire Code 10.- CONTRACTOR SHALL VERIFY DIMENSIONS OF ALL EQUIPMENT (E) 2119GNJFCRNIAQIffiNOSE: California Building Standards Commission Q ADDITIONAL NOTES COVERED R MANUFACTURERS. 2919CAJFCRN1AEN7RGYOCLDE: California Energy Commission PATIO 11, GENERAL CONTRACTOR SHALL NOTIFY ALL APPLICABLE LOCAL ALL OR EQUAL SUBSTITUTIONS MUST BE SUBMITTED GOVERNING,AUTHORITIES AND UTILITIES PRIOR TO COVERING UP ANY TO,AND APPROVED BY THE BUILDING OFFICIAL PRIOR LLLL WORK REQUIRING INSPECTION. TO INSTALLATION OF THE ITEM. GENERAL INFORMATION 12.- PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS THE DEVELOPER/CONTRACTOR/OWNER IS 9.erM• w1•� WHERE REQUIRED. RESPONSIBLE FOR THE VERIFICATION OF EXISTING CURB 13.- ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY LOCATION(OR EDGE OF STREET PAVING IF NO CURBS APPLICANUDEVELOPER: SEALED WITH APPROPRIATE SEALANT MATERIAL. EXIST)FROM PROPERTY LINES)WITH THE PUBLIC VINCERE INDUSTRIES These drawl are an instrument of Service and remain WORKS DEPARTMENT. 43-737 AVENIDA ALICANTE 14.- UNLESS OTHERWISE NOTED,ALL EXTERIOR AND INTERIOR EXPOSED � `; ' • ALUMINUM WIRES SMALLER THAN 1-0 g PROHIBITED. - ' ,'�%i the are tD f G Lpr DESIGN GROUP. D METAL,TRIM,TREILLAGE,RAILINGS,MOLDING,FRAMES,CASTING,ETC., ----'---- �' /��'/ ���' PALM DESERT,CA 92211 SHALL BE PAINTED. SEPTIC FOR NEW STRUCTURES IS NOT ACCEPTABLE.CITY /f� They are not TO IJ2 eeprelpra fd tN altered TO Arlo lllircl ORDINANCE REQUIRES SEWER HOOK-UP. a PROJECT ADDRESS: �,„y witLA the eXG Written Permissionof 15.- SEE SOILS REPORT FOR RECOMMENDATIONS REGARDING CORROSIVE - 43-737 AVENIDA ALICANTE, G LA DESIGN G RO U P SOILS.ALL METALLIC UTILITY LINES SHALL BE CORROSION PROTECTION. • FOUNDATION ELEVATION MUST BE 18"ABOVE TOP PALM DESERT,CA 92211 16.- SPECIFY WEATHER-RESISTANCE BARRIER AT ALL EXTERIOR WALLS(CRC§ CURB OR CROWN OF STREET UNLESS ENGINEERED NO. REVISIONS DATE R703).NOTE: ONE LAYER OF NO.15 ASPHALT FELT,FREE FROM HOLES DESIGN PROVIDES EQUIVALENT PROTECTION.L 805 ASSESOR'S PARCEL No. AND BREAKS,COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR OTHER CBC ORD.AMENDMENT) ONE 637-341-077 APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR AN AUTOMATIC RESIDENTIAL SPRINKLER SYSTEM SHALL ACREAGE: SHEATHING OF ALL EXTERIOR WALLS.(CRC§R703.2). BE INSTALLED IN ALL NEW ONE AND TWO FAMILY 17.- THE INSULATION INSTALLER SHALL POST IN A CONSPICUOUS PLACE IN DWELLINGS AND TOWNHOMES.CRC R313. l EXISTING GROSS: 0.00 ACRES MAIN RESIDENCE THE BLDG.A STATE INSULATION CERTIFICAT SIGNED BY THE INSTALLER FLASH AND COUNTERELASH ALL EXTERIOR OPENINGS. ZONING, STATING THAT THE INSULATION IS CONSISTENT WITH THE PLANS AND WEATHER-STRIP ALL EXTERIOR DOORS PER CRC R703.8. CONFORMS TO THE STATE ENERGY REGULATIONS NOTE ON PLANS TITLE �'� ' _ R-1C EXTERIOR WALLS MUST COMPLY WITH CRC R302.1- 24. TABLE RR WALLS ] �' ` BUILDING TYPE OF CONSTRUCTION: 18.- THE BUILDER SHALL PROVIDE THE BLDG OWNER MANAGER AND / TYPE V-B ORIGINAL OCCUPANTS WITH A LIST OF THE FEATURE,MATERIALS, COMPONENTS AND MECHANICAL DEVICES INSTALLED IN THE BUILDING; ONE STORY INSTRUCTIONS ON HOW TO USE THEM EFFICIENTLY AND,MAINTENANCE GENERAL SPECIFICATIONS - I DWELLING UNIT FOR EFFICIENT OPERATION NOTE ON THE PLANS TITLE 24.SECTION OCCUPANCY( •• 10-103R). IF ANY ERRORS,DISCREPANCIES OR OMISSIONS APPEAR IN COVERE Y %f 19.- ALL SHOP WELDING SHALL BE DONE BY AN"APPROVED" ICBO THE DRAWINGS,SPECIFICATIONS OR OTHER CONTRACT -_ENTRY_ '�',� R-3/U FABRICATING SHOP PRIOR TO ANY STEEL BEING FABRICATED AND SENT DOCUMENTS,THE GENERAL CONTRACTOR SHALL NOTIFY /r TO THE JOBSITE.THE FABRICATING COMPANY SHALL BE APPROVED BY THE DESIGNER IN WRITING OF SUCH ERROR OR OMISSION. LEGAL DESCRIPTION: THE DEPARTMENT OF BUILDING AND SAFETY. IN THE EVENT THAT THE GENERAL CONTRACTOR FAILS TO Recorded Book/Page:CM 51/6 GIVE SUCH NOTICE BEFORE CONSTRUCTION AND/OR Subdivision Name:INT IN COM LOTS 42&43 TR O 20.-THE CONTRACTOR SHALL FIELD VERIFY THE SITE CONDITIONS AS FABRICATION OF THE WORK,THE GENERAL CONTRACTOR / REPRESENTED IN THE PLANS AND REPORT ANY DISCREPANCIES TO THE WILL BE HELD RESPONSIBLE TO THE RESULT OF ANY g;;i"', �. Let/ 'iM6 142/049 DESIGNER BEFORE PROCEEDING WITH THE WORK. ERRORS,DISCREPANCIES OR OMISSIONS AND THE COST OF ,�y.Ng LoVPacel: RECTIFYING THE SAME. :t ;t;v`.+ •• Block: 5 U 21.-UNLESS NOTED OTHERWISE AS INDICATED,DIMENSIONS ARE TO CENTER Tract Number: LINES OF COLUMNS,AND TO FACE OF WALLS. 22.-ALL CONSTRUCTION AND DETAILS SHALL COMPLY WITH THE CITY OF AREA TABULATIONS: M PALM DESERT BUILDING CODE AND ITS ADOPTIONS,AND WITH ALL UTILITIES NOTE W OTHER APPLICABLE FEDERAL,STATE AND LOCAL ORDINANCES. 'zuE FIRE DAMAGE AREA: 1,285 SQ.FT. 23.-WRITTEN DIMENSIONS GOVERN,DO NOT SCALE DRAWINGS.ANY 1. VERIFY CONNECTION POINTS FOR POWER TELEPHONE O f"`i QUESTIONS REGARDING SAME SHALL BE REFEREED TO THE DESIGNER. AND CATV SYSTEMS PRIOR TO CONSTRUCTION `" LEI APPROXIMATE ONLY LOCATIONS INDICATED FOR DEWA K yM�ip► .fig r'�,. Q 24.-ANY/ALL LUMBER IN CONTACT WITH CONCRETE FLOOR OR FOOTINGS TRANSFORMER LOCATIONS,ETC. 4RT' {Nra I N dT' SHALL BE F.G.REDWOOD OR PRESSURE TREATED,"WOLMANIZED". SHEET INDEX T 2. COMPLY WITH ALL UTILITY COMPANY REQUIREMENTS. ;; i 25.-ALL FRAMING LUMBER SHALL BE GRADE MARKED WITH QUALITY PER C.RC. PROVIDE ALL RELATED CONDUITS,PULL BOXES AND _ (CALIFORNIA RESIDENTIAL CODE)REQUIREMENTS. RISERS. At SITE PLAN 26.-USE APPROVED FLASHING MATERIALS AT ALL EXTERIOR OPENINGS,UNLESS 3. CONTRACTOR SHALL VERIFY ACTUAL DEPTH AND .g;. A2 REFERENCE FLOOR PLANUj NOTED OTHERWISE,ALL SHEET METAL SHALL BE 24 GAUGE G.I.OR BETTER, LOCATION OF ALL EXISTING UTILITIES PRIOR TO 5t A3 FLOOR PLAN PAINTED WITH G.I.VINYL WASH PRIMER AND A ZINC DUST PRIMER, CONSTRUCTION...CALL UNDERGROUND SERVICE <'., Vw El ELECTRICAL PLAN EXCEPTING PRE-FINISHED METAL AS APPROVED BY THE DESIGNER. ALERT(TOLL FREE 811) PRIOR TO TRENCHING, 1•fi • 27.-PROVIDE ONE 15 POUND WATERPROOF FELT MINIMUM UNDER ALL GRADING,EXCAVATING,DRILLING, PIPE PUSHING, EXTEROR COVERING. PLANTING TREES,DIGGING FENCE POST HOLES ETC. SCOPE OF WORK 28.-ALL EXTERIOR WALL OPENINGS,FLASHING,COUNTERFLASHING, THEY WILL SUPPLY INFORMATION OR LOCATE AND EXPANSION JOINTS,SHALL BE CONSTRUCTED IN SUCH A MANNER TO MARK ANY UNDERGROUND FACILITIES. 1.- REMOVE/REPLACE ALL FIRE DAMAGED GYP.BD. W • MAKE THEM WATERPROOF;CAULK AND FLASH WHERE NECESSARY FOR A COMPLETE AND WORKABLE INTALLATION. AVENIDA ALICANTE DR. 2.- REMOVE/REPLACE ALL FIRE DAMAGED A/ 29.-CERTIFIED INSULATION MATERIALS.TITLE 24 SECTION 118. NON-BEARING LUMBER. Mill 30.-INSULATION INSTALLED TO MEET FLAME SPREAD AND SMOKE DENSITY GENERAL CONTRACTOR SHALL VISIT THE JOB SITE 3.- REMOVE/REPLACE ALL FIRE DAMAGED CEILING REQUIREMENTS.NOT MORE THAN 25 AND SMOKE NOT MORE THAN AND VERIFYALL EXISTING CONDITIONS ANDALL INSULATION-REPLACE WITH THE 450. ` SAME W VALUE. UM 31.-AIR INFILTRATION IS MINIMIZED BY SPECIFICATION OF TESTED CONSTRUCTION HOURS 4- REMOVE/REPLACE EXISTING LIGHTING WITH MANUFACTURED DOORS AND WINDOWS AND PROPER SEALING AND ': WEATHERSTRIPPING. OCTOBER 1-APRIL 30 MAY 1 -SEPTEMBER 30 NEW LED LIGHTS. 32.-CONTRACTORS MUST GANG AND CONCEAL FROM VIEW,ROOF VENTS Monday-Friday 7:00am-5:30pm Monday-Friday 6:00am-7:00pm 5.- REMOVE/REPLACE EXISTING ELECTRICAL WIRE WHEREVER POSSIBLE. Saturday 8:00am-5:00pm Saturday 8:00am-5:00pm WITH NEW WIRE VALUE. 33.- ROOF DRAIN DOWNSPOUTS MUST NOT DRAIN ONTO HARDSCAPE OR Sunday NOT ALLOWED Sunday NOT ALLOWED BE VISIBLE FROM TRAFFIC AREAS. Govern.Code Govern.Code 34.-ALL OR"EQUAL"SUBSTITUTIONS MUST BE SUBMITTED TO,AND Holidays NOT ALLOWED Holidays NOT ALLOWED APPROVED BY THE BUILDING OFFICIAL PRIOR TO INSTALLATION OF THE BLOCK WALLS,TRASH ENCLOSURES,TEMPORARY POWER POLES, ITEM. POOLS,SPAS REQUIRE SEPARATE PERMITS. 35.- PROVIDE PRESSURE REGULATOR FOR WATER SERVICE WHERESTATIC 1; VIOLATION OF THE ABOVE WORK HOURS IS A CITABLE OFFENSE UNDER PALM DESERT PRESSURE EXCEEDS 80 P51.(CPC 608.2) MUNICIPAL CODE SECTION, SHEET TITLE 2: ALL CONTRACTORS SHALL HAVE A CURRENT VALID CITY BUSINESS LICENSE PRIOR TO PERMIT ISSUANCE PER PALM DESERT MUNICIPAL CODE,TITLE S. GLAZING NOTES 3: ALL CONTRACTORS AND/OR OWNER-BUILDERS MUST SUBMIT CERTIFICATE OF WORKER'S PROJECT TEAM SITE PLAN COMPENSATION INSURANCE COVERAGE PRIOR TO THE ISSUANCE OF A BUILDING PERMIT PER 1. DELETED. CALIFORNIA LABOR CODE,SECTION 3700. DESIGN DEVELOPMENT: 2. ALL NEW GLAZING FENESTRATIONS WILL BE INSTALLED WITH A 4.- GENERAL CONTRACTORS AND/OR OWNER-BUILDERS SHALL COMPLETE AND SUBMITA (FENESTRATIONS) CONTRACTOR'S LIST FORM TO THE DEPARTMENT OF CODE COMPLIANCE PRIOR TO REQUEST GABRIEL LUJAN&ASSOCIATES CERTIFYING LABEL ATTACHED SHOWING THE"U"VALUE. FOR FINAL INSPECTION PER PAW DESERT ORDINANCE#60. 77-530 Enfield LN.-Building I,Suite#101. 3. ALL GLAZING MUST COMPLY WITH THE CURRENT CRC.R308 5: SCHOOL TAX FEES MUST BE PAID PRIORTOTHE ISSUANCE OF YOUR BUILDING PERMIT. Palm Desen,CA 92211 4. FENESTRATION LABELS SHALL NOT BE REMOVED UNTIL AFTER FINAL 6: THE ISSUANCE OF A BUILDING PERMIT DOES NOTAUTHORIZETHE INSTALLATION OF SITE PLAN DRAWN SHEET NUMBER INSPECTION. MECHANICAL WORK,SUCH AS PLUMBING,ELECTRICAL,HEATING OR REFRIGERATION WHICH J.O.P. REQUIRES A SEPARATE PLUMBING,ELECTRICAL,HEATING REFRIGERATION PERMIT. SCALE:118'=1'.0' - ROVED TEMPORARY SANITARY FACILITIES(I.E.CHEMICAL TOILETS SHALL BE ON THE MATERIAL CONSERVATION CHECKED 'APPROVED PLANS AND INSPECTION CARD MUST BE ON THE JOB SITE AND IN CONSTRUCTION SITE PRIOR TO REQUEST FOR FIRST INSPECTION).HEALTH AND SAFETY CODE,. &RESOURCE EFFICIENCY Al A WATER PROOF AND TAMPER PROOF CONTAINER. 8. CONTRACTOR AND/OR OWNER SHALL PROMDE A TRASH BIN TO INSURE PROPER CLEAN-UP OF �: G.L.A. ALL BUILDING MATERIALS. (Enhanced Durability&Reduced Maintenance) ''TEMPORARY TOILET and TRASH ENCLOSURE MUST BE ON JOB SITE PRIOR TO 9: STORAGE OF BUILDING MATERIALS OR DEBRIS SHALL BE CONFINEDTOTHE LOT FOR WHICH STARTING ANY WORK. THE PERMIT IS ISSUED.ADJACENT VACANT PROPERTIES MAY NOT BE UTILIZED FOR THIS 4.406.1 Rodent proofing DATE PURPOSE UNLESS WRITTEN PERMISSION OF THE OWNER IS ON FILE WITH THIS OFFICE.THE Annual space around pipes,electrical cables,Conduits or other JUNE STRUCTURAL: PUBLIC RIGFR-OF-WAY SHALL BE MAINTAINED INACLEAR CONDITION AT ALL TIMES. openings in Sole/bottom plates at exterior walls Shall be protected CHARLES D.GARLAND 2022 NOTE:THE EXISTING SMOKE ALARMS AND CARBON MONOXIDE ALARMS WILL 10.TEMPORARY POWER POLES,SITE MASONRY WALLS,WATER FEATURES,POOLS AND SPAS against the passage of rodents by closing such openings with ARCHITECT SCALE J O B N O. BE VERIFIED BY THE CITY BUILDING INSPECTOR. REQUIRE SEPARATE PERMITS. cement mortar,concrete masonry or a similar method acceptable 74-991 Joni Dr.#9 PD-0627-2K22 to the enforcing agency. Palm Desen,CA 92211 AS NOTED Printed On:07/13/22 J1= GLA DESIGN CRouPUC AJCII���Mr AfflVR�R�E/�WWTR EXISTING GLAZING G%OmEL LW/'!♦Y TO REMAIN REAR COVERED / / / // / / // / / DRAFTING • DESIGN • LAND PLANNING ExrsnNc ( PATIO , / / / //// / /� / // / // / // / / GQBRIELLUJAN SMOKE/WATER PRINCIPAL DESIGNER EAMAGE INSULWAI EXISTI RE AIN DAMAGED GVP.BD. DAMAGED INSULATAION TO REMAIN 75-178 GERALD FORD DR.,$TE.Bl TO BE REMOVED TO BE REMOVED/REPLACED XISTING DOORS / / / / / / / / / / / / / / / / / /REPLACED WITH SAME VALUE TO REMAIN // / / / / / / / / / / / / PALM DESERT,CA.9221 1 / / / / / / / / / / / / CELL(760)578-8545 FAX:(760)674-8100 EXISTING GLAZING // / // / �/ / // / // / // / EMAIL-gluian@gladesigngroup.com TO REMAIN EXISTING SMOKEWATER DAMAGED CLG.GYP.BD. EXISTING TO BE REMOVED SMOKENVATER /REPLACED DAMAGED GYP.BD. TO BE REMOVED BEDROOM2 REPucD EXISTING EXISTING EXISTING SMOKFANATER EXISTING SMOKE/WATER SMOKEANATER DAMAGED INSULATAION SMOKY WATER DAMAGED INSULATAION AMAGED GYP.BD. TO BE REMOVED/REPLACED DAMAGED GYP.BD. TO BE REMOVED/REPLACED TO BE REMOVED TO BE REM01(ED WITH SANE VALUE / // / / // / / // / / / / // / / // / / // / These drawings are an irrStrurcE.rrt of service and rennin WITH SAME VALUE /REPLACED /REPLACED`� / / / / / / / / / / / / / LIVI AREA // / / // / / // / / // / / // / / // / / // / thepropertyof GLA DESIGN GROUP. W / / / / / They are not to be rclxociced or altered to ary third ' EXISTING SMOKEANA ATEiR party Wthout the express writtm permission of / / / / / / / _�_ _ _ /_ _ _ /_ _ DAMAGED CLG.GYP BD. / / / / / / / / / � / / % / / GLA DESIGN GROUP TO BE REMOVED/`� REPLACED / / / / / / / / // ,— / NO. REVISIONS DATE EXISTING / EXISTING SMOKEIWATER SMOKEIWATER DAMAGED GYP.BD. DAMAGED GVP.BD. TOE REMOVED TO BE REMOVED /REPLACED /REPLACED EXISTING SMOKE/WATER DAMAGED CLG. TO BE REMOVED/ REPLACED ��^1IRI EXISTING //// / //// / //// / //// / '�- -a' / / / / •• EXISTING B T RO M fAIJ+ Y SM"'WATER EXISTING SMOKEAVATER ____ AMAGED GVP.BD. SMOKEANATER DINING DAMAGED GYP.BD. TO BE REMOVED DAMAGED CLG.GYP.BD. TO BE REMOVED /REPLACED /REPLACED REPLACED EXISTING SMOKFANATER —EXISTING DAMAGED INSULATNON SMOKEAWATER TO BE REMOVED/REPLACED AMAGED VP.BD.II // / / / / / / / / / / / / u WITH SAME VALUE TO BE REM DVED I KITCHEN / //i �// /� // / / // / ! /_� m I EXISTING SMOKEAVATER EXISTING EXISTING SMOKF7WATER MAIN MAGED GYP.BD. / / / / / / / / / / / / / / / / / G`• SMOKEANATER DAMAGED INSULATAION ENTRY L TO BE REMOVED DAMAGED GYP. D. TO BE REMOVED/REPLACED /REPLACED TO BE REMOVED WITH SAME VALUE /REPLACED I EXISTING SMOKEANATER O /} / // / / // / // / / // / / // / / W DAMAGED CLG.GYP.BD. T BE REM VED/ �� IL_DW 1-----J /L 7/ ✓_ / / // / j / / // / / // / / // / • REPLACED --------------�___ ____ __' BEDROOM 1 ---------- EXISTING EXISTING SMOKF/WATER SMOKENVATER / / / / / / / / / / / / / / / / / / / / W • DAMAGED INSU TO E HSAMD/PLAC D TOVALUERE BE REMODED //// //// //// // //// //// /// Ix 5: L _ XISTING GLAZIN / TO REMAIN WORK SHALL BE INSTALLED IN ACCORDANCE WITH / / THE APPROVED CONSTRUCTION DOCUMENTS,AND / ANY CHANGES MADE DURING CONSTRUCTION THAT / ARE NOT IN COMPLIANCE WITH THE APPROVED / / / CONSTRUCTION DOCUMENTS SHALL BE RESUBMITTED / FOR APPROVAL AS AN AMENDED SET OF CONSTRUCTION DOCUMENTS.CRC R106.4. / / / UPON COMPLETION OF THE INSTALLATION OF THE INSULATION, A CARD CERTIFYING THAT THE INSULATION HAS BEEN INSTALLED / / IN CONFORMANCE WITH THE REQUIREMENTS OF THESE x REGULATIONS SHALL BE COMPLETED BY THE INSULATION SHEET TITLE APPLICATOR AND BY THE BUILDER.THIS INSULATION COMPLIANCE CARD SHALL BE POSTED AT CONSPICUOUS LOCATION WITHIN THE DWELLING. REFERENCE FLOOR PLAN SCOPE OF WORK REFERENCE FLOOR PLAN 1.- REMOVE/REPLACE ALL FIRE DAMAGED GYP.BD. SCALE:V4^=P-9' 2.- REMOVE/REPLACE ALL FIRE DAMAGED NON-BEARING LUMBER. DRAWN SHEET NUMBER 3.- REMOVE/REPLACE ALL FIRE DAMAGED CEILING J.O.P. AND WALL INSULATION-REPLACE WITH THE CHECKED SAME VALUE. G.L.A. 4.- REMOVE/REPLACE EXISTING LIGHTING WITH NEW LED LIGHTS. DATE 5.- REMOVE/REPLACE EXISTING ELECTRICAL WIRE JUNE WITH NEW WIRE VALUE. 2022 SCALE JOB No. AS NOTED PD-0627-2K22 Printed On:—1-2 ® KEY NOTES "ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA RESIDENTIAL,MECHANICAL,ELECTRICAL, PLUMBING,GREEN BUILDING AND ENERGY CODES AND 1.- (E)2 x 4 @ 16"O.C.STUD WALL W/R-15 INSULATION @ EXTERIOR WALLS. THE PALM DESERT MUNICIPAL CODE" 2.- (E)2 x 6 @ 16"O.C.STUD WALL-PLUMBING WALL,(IF EXTERIOR,INSTALL R-21 INSULATION). 3.- (E)2 x 4 @ 16"O.C.STUD WALL-INTERIOR-(PROVIDE SOUND INSULATION -BY OWNER). UPON COMPLETION OF THE INSTALLATION OF THE 4.- (N)DOUBLE SINK WITH GARBAGE DISPOSAL(VERIFY DIMENSIONS WITH INSULATION,A CARD CERTIFYING THAT THE INSULATION MANUFACTURED SPECIFICATIONST-SELECTED BY OWNER. HAS BEEN INSTALLED IN CONFORMANCE WITH THE EXISTING 2X4 WALL W/ 5.- (N)DISHWASHER(VERIFY DIMENSIONS WITH MANUFACTURER REQUIREMENTS OF THESE REGULATIONS SHALL BE NEW R15 INSULATION \ SPECIFICATIONS). COMPLETED BY THE INSULATION APPLICATOR AND BY 6.- IN)PROVIDE 36"REFRIGERATOR SPACE WITH PLUMBING FOR ICE MAKER THE BUILDER. THIS INSULATION COMPLIANCE CARD RECESSED IN WALL. SHALL BE POSTED AT CONSPICUOUS LOCATION WITHIN 7.- IN)36"HIGH KITCHEN OR BAR COUNTERTOP w/BASE CABINETS THE DWELLING. (COUNTERTOP AND CABINETS SELECT BY OWNER). NEW 5/8"TYPE"x" 8.- (N)36"HIGH BATH COUNTERTOPS w/LAVATORY SINK&BASE CABINETS GYP.BOARD (COUNTERTOP AND CABINETS SELECT BY OWNER). FOR EXHAUST FANS: QA DMGN�= 9- (N)UPPER CABINETS W./RAISED BOTTOMS FOR FLOURECENT LIGHT . 50 CFM FOR BATHROOMS AND LAUNDRY ROOM, � FIXTURES WANTEGRAL PLASTIC DIFFUSER,TYP.(GENERAL LIGHTNING.) . 100 CFM FOR KITCHEN. AJOIM �"'��•�rr��r"� SELECT BY OWNER. 10.-(E)50 GAL WATER HEATER,PROVIDE 18"HIGH MIN.WOOD-FRAMED AND ...,n-. DRYWALL-COVERED PLATFORM AT GARAGE ONLY. PROVIDE P&T VALVE GAMEL�V DISCHARGE LINE TO OUT-SIDE. PROVIDE SEISMIC STRAPS-SEE DETAIL. GLAZING NOTES //������/��//���� VENT TO OUTSIDE.INSTALL BY MANUF SPECS. 1/2"SOON ASSOCL �B 11.-IN)36"RANGE W/HOOD[SEE RESIDENTIAL INDOOR AIR QUALITY AND 1: GLAZING IS FIXED UNLESS NOTED. BOARD. MECHANICAL VENTILATION NOTE]. 2: ALL GLAZING SHOWN IS DUAL INSULATING GLASS. 12.-IN)SHOWER(FINISH BY OWNER)w/TEMPERED GLASS ENCLOSURE. 3.- ALL NEW GLAZING(FENESTRATION)WILL BE INSTALLED DRAFTING • DESIGN • LAND PLANNING NOTES: WITH A CERTIFYING LABEL ATTACHED,SHOWING THE a. Compartment walls finished with a smooth,non-absorbent surface to a height not des U-VALUE. GQBRI EL LUJAN than72 inches(6'-0'9 above the drain inlet.(CRC R307.2) 5.- GLAZING MARKED WPECTOR 5 HAS IT. ON THE __________________________ 4.- ALL GLAZING SHALL HAVE A TEMPORARY PRINCIPAL DESIGNER b. 'Gypsum green board'matedal is not permitted In shower compartment for file PRODUCT UNTIL INSPECTOR HAS I6"TEMPERED I❑ I❑ , , 75-178 GERALD FORD DR.,$TE.BI TEMPERED GLASS. / / / / / / / / / sudaces.(CRC R702.3.8.1) 1 / / / / / / / / / PALM DESERT,CA.92211 c. Ashower or tub shall have a minimum ceiling height of 6 feet 8 inches above a // / / //,/ / CELL(760)578-8545 FAX:(760)674-8100 minimum area of 30'k 30"at theshowerhead.(CRC R305.1) / / / / / / / / / / / / EMAIL-glujan@gladesigngroup.com d. 'Ho[-mopped showern 22 22 pan shall 6e inspected upon completion of hot-napping arid WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE REAR shall be filled with water for inspection."CPC§R411.8.1. APPROVED CONSTRUCTION DOCUMENTS,AND ANY COVERED 13 (W WATER CLOSET TO MINIMUM OF IS"TO FINISH VERTICAL CHANGES MADE DURING CONSTRUCTION THAT ARE PATION .- SURFACE OF SIDES(MIN).WATER CLOSET SHALL BE"ULTRA LOW FLUSH" NOT IN COMPLIANCE WITH THE APPROVED 14.-(N)PP PROVIDE TOWEL BAGALLR,S MIN.PAPER HOLDER,RECESSED,MEDICINE CABINET CONSTFOR AP ROVVALDOCUMENTS AS AN AM ENDED SET OF RESUBMITTED s1 I 2 0 ////,,/////,,, ✓//,,,////,,,////,,///////// (MEDICINE CABINET TOP AT 72"HT.F.F.F.)MIRROR TYPE AT BATHS(SIZE CONSTRUCTION DOCUMENTS.CRC R106.4.AND POWDERSH PER ROOM IF AVAILABLE.*FNCTOR).OMIT ALL LOCAATIONSEBYCINE OWNER B ET AT 22 22 NOTE: ALL INSULATION MATERIALS SHALL HAVE A BAEDROOM �` ❑ (N)SHELF&POLE(T.SHELF @ 70"FROM FINISH FLOOR). #2 FLAME-SPREAD RATING NOT TO EXCEED 75 AND A SMOKE 16.-HOSE BIBB WITH SHUT-OFF VALVE e ANTI-SIPHON VALVE AT ENTRY. DENSITY NOT TO EXCEED 450.CBC. I / / / / / / / / / / / / / / �draWi are an If1S1rIJBL`rlt Of SETVICe and retrain i 7.-SMOKE DETECTORS are required to be mounted on the ceiling or wall and located '/ � as specified below. If retrofitted,detectors may be battery operated(Code B / ,/ / / ,/ / / ,j/ / / ,/ / / ,/ / / ,/ / / , the property c(G LA DESIGN G R O U P. references:CBC 907.2.11.5 and CRC R314). , / , /;j / / , / / / / / / They are riot to be reproduced or altered to any third a. Outside of each separate sleeping area in the immediate vicinity of ENERGY EFFICIENCY NOTES / / // / / // /:/ // / // / / // / / // / / // party without the express Written permission of bedrooms. LIVING GLA DESIGN GROUP b. In each room used for sleeping purposes. 1.- "ALL HOT WATER PIPES RUN FROM THE HEATING `"AREA 22 c. In each story within a dwelling unit,including basements,but not including SOURCE TO THE KITCHEN FIXTURES SHALL INCLUDE / / / / / / / / / / / / / / 3❑ / / / �% / / / / / / / / / NO. REVISIONS DATE crawl spaces and uninhabitable attics.In dwellings or dwelling units with A MINIMUM OF 1 INCH INSULATION."(CALIFORNIA 22 3 split levels and without an intervening door between the adjacent levels,a ENERGY CODE 151(F)8D). smoke alarm installed on the upper level shall suffice for the adjacent lower '0 level provided that the lower level is less than one full stor 2.- 'PROVIDE MINIMUM R-12 INSULATION FOR SMALL y below the upper STORAGE WATER HEATERS WITH AN INPUT RATING level. LESS THAN OR EQUAL TO 75,000 BTU/HR. � CARBON MONOXIDE ALARMS are required to be mounted on the wall (CALIFORNIA ENERGY CODE 1500)1). -12 yIF or ceiling or other location as specified in the manufacturer's installation 3.- "THE ENTIRE LENGTH OF RE-CIRCULATING / / / / / / / / instruction and located as specified below.If retrofitted,alarms may b 2e DISTRIBUTION SECTIONS OF DOMESTIC WATER 2 // / // battery operated where the repairs or alterations do not result in removing SYSTEMS SHALL BE INSULATED,REGARDLESS OF wall and ceiling finishes or there is no access to the attic,basement or crawl WHETHER THE PIPING IS BURIED OR EXPOSED." 22 3 22 // / / / / / / / space(Code references:CBC 420.4 and CRC R315). (CALIFORNIA ENERGY CODE 1500)2) a. Outside of each separate sleeping area in the immediate vicinity of 2 bedrooms. HALLWAY b. On every level of the dwelling unit NOTE:NO DISHWASHING MACHINE SHALL BE DIRECTLY 13 T R BAR c. For R-1 Occupancies only-on the ceiling of sleeping units with permanent) CONNECTED TO A DRAINAGE SYSTEM OR FOOD Y installed fuel burning appliances. DISPOSER WITHOUT THE USE OF AN APPROVED AIR GAP I I 2 / / / / / / / / / / / / /� A/ 18.-STOVE,OVEN&MICROWAVE w/HOOD,LIGHT&FAN.MECHANICAL FITTING ON THE DISCHARGE SIDE OF THE 2 ® // // / / ®7 EXHAUST VENT TO BE DUCTED TO OUTSIDE WITH A MINIMUM DISHWASHING MACHINE. I I I / / / / / / / / , / / / / VENTILATION RATE OF 100 CFM.PROVIDE 30"CLEARANCE ABOVE RANGE CPC SECTION 807.3. O OR COOKTOP TO UNPROTECTED COMBUSTIBLE MATERIALS,OR 24" r--- /, / CLEARANCE TO METAL VENTILATING HOOD.[SEE"LOCAL EXHAUST KITCHEN '�, 7 20 3 22 / / ,/// / //// / //// / //// VENTILATION RATE SUMMARY"NOTE PAGE M.i]. 2 ° �- DINING // // // // / 19.-WASHER(PROVIDE PLUMBING FOR WATER AND SEWER IN RECESSED WALL WALL LEGEND& KEY NOTES / / / / / / / / / / / I UM BOX). AREA 20.-DRYER(PROVIDE VENT TO OUTSIDE AIR WITH BACK DRAFT DAMPER) DRYER VENT TO O.S.A.W./BACKDRAFT DAMPER AS REQUIRED.4"MIN. EXISTING 2X4®16"O.C.STUDS WALL DIAMETER DRYER VENT TO EXTERIOR 14'-0"LONG MAX.LENGTH WITH A WITH RR-15 INSULATION®EXTERIOR LS6 1/2"GYP.BD.TO REMAIN. MAX.OF(2)TW090 ELBOW BENDS. WAL WALK 223 /// / ,/ / / ,/ / / ,/ / //, I //%, / / / 21.-EXHAUST FAN[EACH BATHROOM CONTAINING A BATHTUB OR SHOWER _ ExlsnNc zx®tee O.C.PLUMBING sTuos - - '?�j�F SHALL HAVE AN EXHAUST FAN.(CRC R303.3.1). © WALL WITH R-21 INSULATION®EXTERIOR CLO ET 22.-(N) GYP.BOARD WALLS(TYPJ. E EXTERIOR WALLS O.C.YP.BD.AL 3 WALLS 1/2"GYP.BD. , 1 23.-SE BAR SINK(VERIFY DIMENSIONS WITH MANUFACTURED PECIFICATIONS).- 0 EXISTING 2X4 @LLS O.0 STUDS WALL 2 _ _ 3 3 9 I, / /� / / / /r / / / _✓ _1 / SELECTED BY OWNER. REMAIN. 24.-GAS METER. 25.-EXISTING 2X4 WALL W/NEW RI INSULATION,NEW 5/8"TYPE"X"GYP. O I EXSTING 2X4 @ 16"O.C.STUDS WALL BOARD OVER 1/2"SOUND BOARD. REMAIN.ERIOR WALLS vr'GYP.BD.To 22 3 22 3 MAIN ;' KITCHENIB / / / / / / / / / / / / / R L T / ENTRY W FLOOR PLAN NOTES SQUARE FOOTAGE I.- WATER PROOFING AT ALL SHOWERS TO BE DONE BY ROOFING CONTRACTOR. FIRE DAMAGE AREA: 1,M5 SQ.FT. O 4 5❑ B 2.- HOT MOPPED SHOWER PAN SHALL BE INSPECTED UPON COMPLETION OF HOT I W MOPPING AN SHALL BE FILLED WITH WATER FOR INSPECTION. BAEDROOM ` pW 1 / / /�/ ,/ `/� ,/ / / ,/ / / ,/ / / ,/ 3.- USE WATER RESISTANT GYP.BOARD IN TUB AND AND SHOWER AREA TO A HEIGHT I #1 i MG / / r/ / '/ / / >\ / / / / / / / / / / 72"ABOVE DRAIN INLET.PERCBC807.1.3. Ix 5: ------------ OF // / / // / / // 4: TILE LINED TUBS&SHOWERS SHALL CONFORM WITH AMPO STD.2.82&4.82. 5.- WATER HEATER SHALL BE PROVIDED WITH A TEMPERATURE AND PRESSURE RELIEF VALVEANDDRAIN O EUM 6.- WA ER HEATER SHALL BE SECURELY FRST NED OUTSIDE S N PLACE TO PREVENT HORIZONTAL /// /// /// / /// /// /// DISPLACEMENT PER CPC. 7.- FIXTURES HAVING CONCEALED SLIP JOINT CONNECTIONS SHALL BE PROVIDED WITH ' AN ACCESS PANEL OR UTILITY SPACE AT LEAST 12"XI2"PER CPC. 8.- WHERE ANY 2"VENT RUNS HORIZONTALLY THROUGH WALL STUDS,THE MINIMUM i / O STUD SIZE OF 2X6 SHALL BE USED FOR THAT PLUMBING WALL. 9.- DRYER DUCT TO BE SMOOTH METAL AND SHALL HAVE A BACK DRAFT DAMPER PER CMC. 10:ALL INSULATION MATERIALS SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY NOT TO EXCEED 450. 11:PROVIDE FIRE BLOCKING AT ALL INTERSECTIONS BETWEEN CONCEALED WALL AND HORIZONTAL SPACES SUCH AS SOFFITS,ROOFS OR CEILING. ,// / / SHEET TITLE 12.-DRYER DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH EACHOF 1 DFT.INCLUDING EGREE E BOW 2 90 DE RE 2 ELBOWS.TWO FEET SHALL BE DEDUCTED ,/ / / , FLOOR PLAN 13.-ALL DIN EQUAL"SUBSTITUTIONS MUST BE SUBMITTED AND APPROVED BY THE CITY , / , BUILDING OFFICIAL PRIOR TO INSTALLATION OF THE ITEM. 14:PROVIDE NON-REMOVABLE BACK FLOW PREVENTION DEVICE ON ALL EXTERIOR HOSE-BIBS.CPC 1003 UPON COMPLETION OF HOT MOPPING. 15.-HOT-MOPPED SHOWER PAN SHALL BE INSPECTED&FILLED WITH WATER FOR INSPECTION. 16:FIXED APPLIANCES ARE REQUIRED TO BE SECURELY FASTENED IN PLACE PER U.M.0 504 DRAW N SHEET NUMBER 17.-PROVIDE A NON-REMOVABLE BACKFLOW PREVENTION DEVICE ON ALL EXTERIOR f.O.P. HOSE BIBBS.CPC.603.0&603.1 FLOOR PLAN CHECKED SCALE:114'=1'-0' G.L.A. ALL NEW GLAZING(FENESTRATIONS)WILL BE INSTALLED WITH A CERTIFYING LABEL ATTACHED,SHOWING THE U-VALUE. DATE ALL WEATHER-EXPOSED SURFACES SHALL HAVE A WEATHER-RESISTIVE BARRIER TO PROTECT TUNE THE INTERIOR WALL COVERING AND THAT EXTERIOR OPENINGS SHALL BE FLASHED IN 2022 SUCH A MANNER AS TO MAKE THEM WEATHERPROOF.SECTION 1402. f O B N O. SCALE DOORS MAY OPEN INTO THE GARAGE ONLY IF THE FLOOR OR LANDING IN THE GARAGE IS PD-062 7-2 K22 NOT MORE THAN ONE INCH LOWER THAN THE DOOR THRESHOLD.1004.9. AS NOTED Printed On:a7/13/22 ELECTRICAL NOTES ELECTRICAL SYMBOL SCHEDULE 1. "ALL 120 VOLT,SINGLE PHASE,15-AND 20-AMPERE BRANCH CIRCUITS $ STANDARD SWITCH. SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS,DINING THREE-WAY OR FOUR-WAY LIGHT SWITCH AS NOTED.o �� ROOMS,LIVING ROOMS,PARLORS,LIBRARIES,DENS,BEDROOMS, SUNROOMS,RECREATION ROOMS,CLOSETS,HALLWAYS,OR SIMILAR ROOMS STANDARD DIMMER SWITCH. OR AREAS SHALL BE PROTECTED BY AN LISTED ARC-FAULT CIRCUIT INTERRUPTER,COMBINATION TYPE,INSTALLED TO PROVIDE PROTECTION OF 4b SWITCH W/OCCUPANCY SENSOR. THE BRANCH CIRCUIT.".(CEC 210.12(B)) 120V DUPLEX CONVENIENCE RECEPTACLE(AFCB AT 12"ABOVE 2. ALL EXTERIOR RECEPTACLE OUTLETS,GARAGE AND BATHROOM RECEPTACLE VV FLOOR,UNLESS NOTED OTHERWISE OUTLETS,AND RECEPTACLE OUTLETS SERVING KITCHEN COUNTERTOPS SHALL BE GFCI PROTECTED. 120V CN2240 V,AS NOTED,CONVENIENCE RECEPTACLE WITHIN T� 3. MINIMUM OF TWO SEPARATE 20 AMP SMALL APPLIANCE BRANCH CIRCUITS CABINET,BELOW OR OVERHANG. SHALL BE PROVIDED IN THE KITCHEN. OAKI AT 1 EX CONVENIENCE RECEPTACLE,W/ARC-FAULT 4. OUTLET COMPLY WITH CEC ART.210.52(A) AT 2"ABOVE FLOOR,UNLESS NOTED OTHERWISE. 5. A 20 AMPERE CIRCUIT DEDICATED TO EACH BATHROOM OR AT LEAST ONE 20 (yI�L, 120V DUPLEX CONVENIENCE RECEPTACLE,W/GROUND-FAULT AMPERE CIRCUIT SUPPLYING ONLY BATHROOM RECEPTACLE OUTLETS. TTCKI CIRCUIT INTERRUPTOR. M. a�• 6. ARC-FAULT CIRCUIT INTERRUPTERS)SHALL BE PROVIDED TO ALL 15 AND 20 �•V GW" l..w. AMP RECEPTACLE OUTLETS INCLUDING RECEPTACLES,LIGHTS,AND SMOKE `FYcrcl AT V FOURPLEX ABOVE FLOOR,UNLESS RECEPrACUE,W/ FAULT DETECTORS. A�w r`w�••�`WM 7. A 20 FOOT LONG#L UFER GROUNDING ELECTRODE SHALL BE PROVIDED FOR zxo"( zxw 1Y1 �V' YM THE GROUNDING ELECTRICAL SYSTEM.GAS AND WATER LINES SHALL BE 240V SINGLE CONVENIENCE RECEPTACLE,VERIFY HEIGHT. BONDED. 8. LUMINAIRES(LIGHT FIXTURES)IN TUB OR SHOWER ENCLOSURES SHALL BE JY I 1 20V DUPLEX CONVENIENCE RECEPTACLE,SWITCH CONTROLLED, /J\d7L7 ����/�A� LABELED"SUITABLE FOR DAMP LOCATIONS".CEC 410.10(D) V GAMLL Uj r 9. A MINIMUM OF ONE 20 AMP.BRANCH CIRCUIT SHALL BE PROVIDED TO / w 120V OR 240V,AS NOTED,WEATHERPROOF DUPLEX RECEPTACLE ALCM ATGC SUPPLY THE LAUNDRY RECEPTACLE OUTLET(S).SUCH CIRCUITS SHALL HAVEFF / // / / // / / // / / W/GFCI. /"��T�ral"N G7 NO OTHEROUTLETS. 10. AFCI BREAKERS FOR USE IN BEDROOMS MUST BE OF THE"COMBINATION / / / / / / / / 120V OR 240V,AS NOTED,FLOOR TYPE DUPLEX RECEPTACLE, - TYPE" DRAFTING • DESIGN • LAND PLANNING 11.NOTE:MECHANICAL EQUIPMENT SUPPORTED DIRECTLY BY THE ua / / / / / / / / / / / / / / / / / / / / RECFSSED FRACTIONAL HP EXHAUST FAN,SWITCH CONTROLLED GROUND SHALL BE ISOLATED FROM THE GROUND BY A LEVEL / / / i/ // / / // Y / // / / // / / // / / // (5 AIR CHANGES PER HOUR). GQBRIEL LUJ,AI\J CONCRETE SLAB EXTENDING NOT LES THAN 3'INCHES ABOVE / / / / / / y / / / / / / / PRINCIPAL DESIGNER THE ADJOINING GROUND LEVEL. / �% / / / / / / / / / / / / / / / / RECESSED COMBINATION LIGHT/EXHAUST FAN SWITCH CONTROLLED 75-178 GERALD FORD DR.,STE.Bl 12 SERVE)DE AT ALL WALLST TWO 20-AMPERE FLOOR,AND COUNTERTOP RECEPTACLES IN KITCHEN,ALL APPLIANCE BRANCH ITS TO _ Ms&Pc� ,�\ / //// ////// /////j/ ///// ////// ////// //// (5 AIR CHANGES PER HOUR). PALM DESERT,CA.92211 PANTRY,BREAKFAST ROOM,DINING ROOM,OR SIMILAR AREA.SUCH CIRCUITS �� 1�Gw / // / / // / // / / // / / // / / // / RECESSED ELECTRICAL CEILING HEATER,SWITCH CONTROLLED. CELL:(760)578-8545 FAX:(760)674-8100 SHALL HAVE NO OTHER OUTLETS.CEC 210.11(C)(1)AND 210.52(B)(1)THROUGH 210.521I(3) (1 i / / / / / / / / / / / EMAIL-glujan@gladesigngroup.com B 1 11 13 "LIGHTING IN ROOMS MUST BETHIGOHOEF ICACYAOR MUST BE CONTROLLED BY A MANUAL-ON ``�y[.E / // //// //// / / //// //// ////// a PH TELEPHONE JACK AT+B"ABOVE FLOOR AND COUNTER. OCCUPANCY SENSOR.A MANUAL-ON OCCUPANCY SENSOR MUST BE / / / / / / / / / / / / / / / / / / / ZJ TELEVISION CABLE JACK AT+8"ABOVE FLOOR. MANUALLY TURNED ON AND AS LONG AS THE SENSOR DETECTS MOVEMENT STAYS ON.WHEN MOVEMENT IS NOT DETECTED,WHICH CANNOT BE LONGERFD FUSE DISCONNECT. THAN 30 MINUTES,THE FIXTURE AUTOMATICALLY TURNS OFF." N / / / / / / / / / / / / / / / / / / / / 14."ALL PERMANENTLY INSTALLED LIGHTING IN OTHER ROOMS,INCLUDING HALLWAYS,DINING ROOMS,BEDROOMS,FAMILY ROOMS,MUST BE HIGH for rnN -^� / / / / / / / / / / / / / / / / / / / / DOOR CHIME PUSH BUTTON. EFFICACY;OR CONTROLLED BY DIMMER,OR A MANUAL-ON OCCUPANCY oaerle SENSOR;THE MANUAL-ON OCCUPANCY SENSORS ARE BEING MANUFACTURED I \Y.v ////// ////// ////// /// // ////// ////// ////// 0 DOORCHIME. lujan AND ARE AVAILABLE.THE EXCEPTION TO THIS 15 A CLOSET UNDER 70'SF.,AND \ n / / // / / // / / // / // / / // / / // / / / HOT OUTLETS FOR LAMPS." n W / / / / / / / / / / / / / / / / / / / / + GARAGE DOOR OPENER PUSH BUTTON. 15."RECESSED LIGHTS INSTALLED IN AN INSULATED CEILING OR CAVITY ARE ni ,11,.�7 / / / / / / / / / / / / / / These drawir)g5 are an irntrurre-of service and rsreirt REQUIRED TO HAVE AZERO CLEARANCE INSULATION COVER 00;BE ASTME 1 _ �X'JX� / / / / / / / / / / / / SENSOREDADDRESS UGHT(NOSWITCH)ILUMINATED BUILDING / \ / / / / / / X / 12345 the property of G LA DESIGN GROUP. 283 CERTIFIED THAT THEY ARE AIR TIGHT;AND SEALED WITH AGASKET OR V~`E\V / / / / / / / / / ADDRESS NUMBERS TO BE A MINIMUM OF 4"HIGH MINIMUM CAULK BETWEEN THE HOUSING AND THE CEILING." U.N.O. all f1ar TO be q'dllEfdd TO 11nlBd They relxallced ary 16."OUTDOOR LIGHTING THAT IS ATTACHED TO A BUILDING MUST BE HIGH ------------------_--- %I .I\ / // / // / // / / // /`1 - - - /� - _ ---/ �y wthDE the a pvss Written permission Of O EFFICACY;CR CONTROLLED BY MOTION EN R WITH AN INTEGRAL I - / / / / /O CO OSENSOR G � xt, / / / O THERMOSTAT,VERIFY LOCATION WITH HEATING/AC LAYOUT. GLA DESIGN GROUP PHOTO-CONTROL.LIGHTING AROUND SWIMMING POOLS,WATER11 \ / / / ! / FEATURES,OR OTHER LOCATIONS SUBJECT TO ARTICLE 680 OF THE CEC ARE "Suitable for yT11 x / / / / EXEMPT. Damp Location' Lein I I J JUNCTION BOX,WITH COVER OR ADAPTER AS REQUIRED. NO. REVISIONS DATE 17.BRANCH CIRCUITS THAT SUPPLY 125-VOLT,SINGLE PHASE,15-AND 20-AMPERE OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY ED `S\ y 1 % / / / / / / / / O SMOKE DETECTOR,120V POWERED W/BATTERY BACK-UP. AND ARC-FAULT CIRCUIT INTERRUPTER. \ j / y / // / // / / / // / S CBC 310.9.1.3.(CEILING MOUNTED,U.N.O.) 18.PROVIDE TAMPER RESISTANT RECEPTACLES AT ALL LOCATIONS. 19. ALL RECEPTACLES IN ACCESSORY BUILDINGS AND OUTDOORS SHALL HAVEED / / / / / / / / GROUND-FAULT CIRCUIT-ACCESSORY (GFCO PROTECTION. I O / // / / // / / // / / / / / / / / ® CARBON MONOXIDE DETECTOR,120V POWEREDW/BATTERY cl. GiCI / / / / / BACK-UP.(CEILING MOUNTED,U.N.O.) 20.PROVIDE AT LEAST ONE 20-AMPERE BRANCH CIRCUIT TO SERVE BATHROOM - ; 7' uCl // //// //// // / //// / / KEY FG RECEPTACLES SUCH CIRCUIT(SI SHALL HAVE NO OTHER OUTLETS.CEC 210.11 LED II1�I��(I , t FUEL GAS AND FUEL GAS CONTROL KEY. AND 210.52 21.PROVIDE VENTILATION TO ALL BATHROOMS IN ACCORDANCE WITH CRC R303.3,ENERGY CODE 150(o);152(a)AND CMC(Table 4-4)A MIN.50 CFM PER FAN REQUIRED. ra Q % / / / / / / / / I % / HOSE BIBB,W/SHl1T CFF VALVE AS NOTED.M6T-ANhV6-9fKN 22.ALUMINUM WIRES SMALLER THAN 1-o PROHIBITED / / / / / / / '� DEVICE OCE0346 FG � 1! ) /a ED // // // / // / / ROUND RECESSED INCANDESCENT LIGHT FIXTURE E z 1 ! i ! // / / // / / // / / // / / / / / / O OIL, "FL"(INDICATES FLUORESCENT) •• J ! / / / / / / a SO,"SD'(SHALL BE LABELED"SUITABLE FOR DAMP LOCATION" CALIFORNIAENERGYCODE / / / / / / / / / / / / / / / LEDNEc41o4(a).EACH ROOMcoNTAININCA SHOWER ORBATHTUB) i IOED / I / / / / / / / / / / / / "LED'(INDICATES LIGHT-EMITTING DIODE(LED)). A. A MINIMUM OF 50 PERCENT OF THE TOTAL RATED WATTAGE OF PERMANENTLY 1 / - - I 1 i z2 / / / / / / / / / / / / / _ / FL SURFACE-FLUORESCENT,INCANDESCENT CEILING LIGHT FIXTURES("FL." INSTALLED LIGHTING IN KITCHENS SHAN BE HIGH EFFICACY. i I I 1 % jc / / / / / / / / � � / / INDICATE FLUORESCENT, i I 1 i / / / / / / / PC LED B. FOR THE PURPOSE OF COMPLIANCE WITH SECTION II 150.0(K),KITCHEN F/' 1 1 y / / / / / / / / / ✓ / �1 / / SURFACE MOUNTED INCANDESCENT WALL LIGHT FIXTURE O LIGHTING INCLUDES ALL PERMANENTLY INSTALLED LIGHTING IN THE KITCHEN 1 - / j / / / / / / �/ / / "FL"(INDICATES FLUORESCENT). EXCEPT FOR LIGHTING THAT IS INTERNAL TO CABINETS FOR THE PURPOSE OFZG/\ ILLUMINATING ONLY THE INSIDE OF THE CABINETS.LIGHTING IN AREAS 11 "LEIIJ �`\ / // / // // / ', ,` // / MS&PC �.S&PC"(INDICATES FIXTURE WWOTION SENSOR AND PHOTOCELL). II _ I ADJACENT TO THE KITCHEN,INCLUDING BUT NOT LIMITED TO DINING AND LE 1 ` / "LED"(INDICATES ligh-iting diode(LED)). i NOOK AREAS,ARE CONSIDERED KITCHEN LIGHTING IF THEY ARE NOT LED / / / / j / / / O s / / / / / _ /_J ELECTRODE COLD WATER BOND SYSTEM. SEPARATELY SWITCHED FROM KITCHEN LIGHTING. ---- --I- �\ ucI �`1 / / / / / /� / EXCEPTION TO SECTION 150.0(K)3:UP TO 50 WATTS FOR DWELLING UNITS LESS �` 1 J G / / / / / / / / / A� /I / y / / / • PENDANT INCANDESCENT LIGHTING THAN OR EQUAL TO 2,500 SQ.T.OR 100 WATTS FOR DWELLING UNITS i `�1 � i / / / I/ / 1 / Q ca LARGER THAN 2,500 SQ.T.MAYBE EXEMPT FROM THE 50 PERCENT HIGH i i 1 / / // / / / / / / / / / / / / / O ROUND ART RECESSED INCANDESCENT LIGHT FIXTURES. EFFICACY REQUIREMENT WHEN ALL LIGHTING IN THE KITCHEN IS CONTROLLED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS IN SECTION 150.0(K)2, / %/ \\ 1 / / / / / / �^L_ UNDER CABINET FLUORESCENT LIGHT FIXTURE(W/LENGTH)SWITCH -AND IS ALSO CONTROLLED BY VACANCY SENSORS OR DIMMERS. // // / // / / // / / // �� CONTROLLED(W/T8 OR TS LAMPS AND ELECTRONIC BALLAST. C. "LIGHTING IN BATHROOMS,GARAGES,LAUNDRV ROOMS,AND/OR UTILITY / .-.-.--''� LED / / // r `/ / / / / / // / / // / / // / ROOMS MUST BE HIGH EFFICACY OR MUST BE CONTROLLED BY A MANUAL-ON HOT SURFACE MOUNTED FLUORESCENT CEILING LIGHT FIXTURE. OCCUPANCY SENSOR.A MANUAL-ON OCCUPANCY SENSOR MUST BE MANUALLY TURNED ON AND AS LONG AS THE SENSOR DETECTS MOVEMENT (� a `OIO_O_O_O, STAYS ON.WHEN MOVEMENT IS NOT DETECTED,WHICH CANNOT BE LONGER / / / / / / / / / / / / / / / / Y-g SURFACE MOUNTED INCANDECENT VANITY LIGHT FIXTURE. THAN 30 MINUTES,THE FIXTURE AUTOMATICALLY TURNS OFF." i C YE d'HSOLATUBE-Installed tLight Dw _ y _/ /I / / / / / / / / b tee. W D. "ALL PERMANENTLY INSTALLED LIGHTING IN OTHER ROOMS,INCLUDING ucl z ---- ---s9Cl /L ✓ / / / / / / / / / FL-Compact Fluoresce-Light Add-On Kit HALLWAYS,DINING ROOMS,BEDROOMS,FAMILV ROOMS,MUST BE HIGH / _ /Ilo /I / _ / / / / ` // / / / / / / U U-Universal Light Add-0n Kit • EFFICACV;OR CONTROLLED BY DIMMER,OR A MANUAL-ON OCCUPANCY SENSOR;THE MANUAL-ON OCCUPANCY SENSORS ARE CLOSET UNDERU-SF.,RED / //// //// /-/ /// ///// ///// //// C_ (, AND ARE AVAILABLE.THE EXCEPTION TO THIS IS A CLOSET UNDER 70'SF.,ANDII/ HOT OUTLETS FOR LAMPS." ��4 CEIUNGMOUNTEDFAN,40RSBLADE, E. "RECESSED LIGHTS INSTALLED IN AN INSULATED CEILING OR CAVITY ARE %%'J `\\ SWITCH CONTROLLED. W REQUIRED TO HAVE A TM 283 CERLK TIFIED THAT EHTHEY DING AND HT;AISDSEALED WITH AGASK T CLEARANCE INSULATION COVER(IC);BE S E OR / V� S\\ • THE CEILING." F. "OUTDOOR LIGHTING THAT 15 ATTACHED TO A BUILDING MUST BE HIGH CHANDELIER(TOBE SELECTED BY OWNER). EFFICACY;OR CONTROLLED BY A MOTION SENSOR WITH AN INTEGRAL PHOTO-CONTROL.LIGHTING AROUND SWIMMING POOLS,WATER FEATURES,OR OTHER LOCATIONS SUBJECT TO ARTICLE 680 OF THE CEC ARE NOTE: EXEMPT. / • AL LOUTLETSTOBETAMPERRESISMNTPERCEC406.IL / • HIGH EFFICACY LUMINARIES MUST BE RN BASED / / / WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE APPROVED SMOKE ALARMS // / / / CONSTRUCTION DOCUMENTS,AND ANY CHANGES MADE DURING SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS(CRC R314.3,: / / / / CONSTRUCTION THAT ARE NOT IN COMPLIANCE WITH THE IN EACH SLEEPING ROOM. APPROVED CONSTRUCTION DOCUMENTS SHALL BE RESUBMITTED FOR OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY O / / / APPROVAL AS AN AMENDED SET OF CONSTRUCTION DOCUMENTS. THE BEDROOMS. / / / CRC R106.4. ON EACH ADDITIONAL STORY,INCLUDING BASEMENTS AND / / /lk V,/ HABITABLE ATTICS. SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH CRC R314.4& UPON COMPLETION OF THE INSTALLATION OF THE INSULATION,A SHEET TITLE R314.5 CARD CERTIFYING THAT THE INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH THE REQUIREMENTS OF THESE REGULATIONS ELECTRICAL CARBON MONOXIDE ALARMS SHALL BE COMPLETED BY THE INSULATION APPLICATOR AND BY THE SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS(CRC R315.3): BUILDER. THIS INSULATION COMPLIANCE CARD SHALL BE POSTED AT PLAN OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE CONSPICUOUS LOCATION WITHIN THE DWELLING. BEDROOM(S) ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING BASEMENTS. CARBON MONOXIDE ALARMS SHALL BE HARDWIRED WITH BATTERY BACK-UP AND INTERCONNECTED UNLESS EXEMPTED IN ACCORDANCE WITH CRC R315.1.1&R315.1.2 DRAWN SHEET NUMBER ALL OUTLETS TO BE TAMPER RESISTANT PER CEC 406.11. J.O.P. ALUMINUM CONDUCTORS ARE PERMITTED ONLY IF SIZE LARGER, ELECTRICAL PLAN CHECKED AND ONLY TO FEED MAIN OR SUB-PANELS.ALL OTHER CURRENT RENEN T CARRYING G.L.A. CONDUCTORS SHALL BE COPPER. SCALE:1W=['-0" DATE El JUNE 2022 SCALE JOB No. AS NOTED PD-0627-2K22 Printed On:a7/13/22