Loading...
HomeMy WebLinkAboutIronwood Mariposa & Irontree CornersLANDSCAPE ARCHITECTS,INC. PROJECT: IRONWOOD COUNTRY CLUB MARIPOSA / IRONTREE CORNERS 73-735 IRONTREE DR. PALM DESERT, CA 92260 PREPARED FOR: IRONWOOD COMMUNITY MASTER ASSOCIATION 73-735 IRONTREE DR, PALM DESERT, CA 92260 -APPROVED- Amended Landsca a Retne-Fit Plan Reviewed a,Y, Landscape M r. _ Date CITY of P LM ESE T PUBLIC AfDrl� DEPT. RGA LANDSCAPE ARCHITECTS, INC. 74020 ALESSANDRO, SUITE "E" PALM DESERT, CA (760) 568m3624 FAX (760) 773-5615 E-MAIL; rga@xga-pd.com INDEX: WATER CONSERVATION STATEMENT Landscape Documentation Package Checklist Ironwood Mariposa / Irontree Corners CONSTRUCTION PLAN AND DETAILS CP-1 Tract or Parcel Number: 655 270 001 2 IRRIGATION PLAN (CORNERS) IP_ 1 Assessors Parcel Number (APN): IRRIGATION DETAILS IP-2 Project Location: Ironwood C.C. Corner of Mariposa Dr. and Irontree Dr. PLANTING AND LIGHTING PLAN (CORNERS) PL-1 Landscape Architect / Irrigation Designer/ Contractor eNz . RGA Landscape Architects, 74020 Alessandro Dr., Ste. E, Palm Desert, Ca. PLANTING DETAILS PL-2 MAINTENANCE AND INSPECTION SCHEDULE PL-3 Included in this Landscape Documentation Package are: X 1. Water Efficient Landscape Works heat WATER BUDGET CALCULATIONS X 2. Maximum Applied Water Allowance. (MAWA): Comentional Landscape: 18T50 100 cubic feet per year Recreational Turf grass Landscape: D.00 100 cubic feet per year Maximum Applied Water Allowance: 187.50 100 cubic feet per year X 3. Estimated Total Water Use by Hydrozone: Very Low Plant Hydrozones: 0.00 100 cubic feet per year STANDARD SYMBOLS AND Low Plant Hydrozones: 73.98 100 cubic feet per year Moderate Plant Hydrozones: 20.56 100 cubic feet per year High Plant Hydrozones: 0.00 100 cubic feet per year ABBREVIATIONS Turf grass Hydrozones 0.00 100 cubic feet per year Recreational Turf grass Hydrozones: 0.00 100 cubic feet per year HDR HEADERBOARD Annual Color 4.54 100 cubic feet per year ALIGN ALIGN ACCORDINGLY Water Features: 0.00 100 cubic feet per year — — LIMIT OF WORK TYP. TYPICAL Estimated Total Water Use (ETWU): 99.08 100 cubic feet per year — —_ SHEET MATCHLINE PA PLANTING AREA MOUNDING l NOT TO EXCEED 3:1) CENTER LINE X 4. ETWU < MAWA E PROPERTY LINE HIGH POINT OF MOUND l IN INCHES J R RADIUS PLAN SETS O <EYNOTE, SEE MASTER LIST ON SHEET EQ EQUALRISERS DETAIL NUMBER MIN WATER SURFACE LEVEL X 5. Landscape Design Plan MIN MINIMUM SHEET NUMBER COL COLUMN X 6. Irrigation Design Plan EXPANSION JOINT HP HIGH POINT LP LOW POINT 7. Grading Design Plan SCORE JOINT DIA DIAMETER POINT OF BEGINNINGS FOR DIMENSIONING CONT CONTINUOUS 8. Soil Management Report �— DIRECTION OF SLOPE, 1% MIN. ON HARDSCAPE HT HEIGHT SIM SIMILAR O.G. ON CENTER I agree to comply with the requirements of the water efficient landscape ordinance and submit a ELEVATION DETAIL D.G. DECOMPOSED GRANITE complete Landscape Document Package. Date: 10/19/2010 Applicant: Luke Taylor REVISIONS SPECIFICATIONS I IPER CVWD COMMENTS 11/4/10 �m 32 SR -Ill SHEETO BOOK �1532 CP 0 Q OF Cii SITE o VINATGEDR.WEST Underground Service Alert o c�mul CVWD LANDSCAPE APPROVAL 4 W 811 These plans have bean reviewed by the Coachella Valley Water District in N yy ph, T � R accordance with Water Code Title 7, Chapter 3, Article 10.8, Section 0 655597 at seq, requiring efficient landscape and Irrigation design in M SA VI TWO WORKING DAYS BEFORE YOU DIG cooperation with the local governing agency (City or County)Approval of (Y 0/ G� this drawing by CVWD staff does not constitute approval to encroach into / q 7 R 1 district and USER Right& -of -Way. Trees, plans„ walla, and permanent R�VTpE structures of any kind may not be planted or installed in CVWD and USSR r PROD NO - # R0812 easements Or nght-of Waywithout first Obtaining �n of oroachmOnt permit ,. ■■ from CVWD. DATE: 5/5/10 XJ&&�2-610 Date G€MENT SUP VISOR A h; VI CI NI T Y MAP NORTH THESE THIS PR AND 3PECIFIAY NO S ARE PRODUCED I A RGA MC. FOR USE ON THIS PROJECT AND MAY NOT HE REPRODUCED D! ANY RAY RITHOUT THE EXPRESSED RRrrEN CONSENT OF RGA. INC. C '10 'CVWD Plan # -. Z—DEVZELOPM s ICES SUPERVISOR L39104 r o q� \ / CP pf EDGE OF / (n3 1^M1 \ CORNER C .� rPROPERTY � � �'� D 0� AREA D1111' 2 Fiflowl 4/4• T / 13/4 D2 f A2 T I ONT _ P.O.C. C: (FOR MEDIANS) tI - EXISTING 1-1/2" WATER METER = AND 2" BACKFLOW PREVENTOR. #1310722 VERIFY SIZE AND LOCATION INf "r FIELD. / ,oil GORNC�R V v PERTY �� AREA �.r'� V .� V �� I r➢/� f' 1'2 I I 1 *SEE PL-1 SHEET FOR LIMIT OF WORK* a EDGE OF I � COMER aR�PERTY LER�\� \ 1; a \ \ O _ fill", illill • L2 1!y "I p I EDGE OF II CORNER PROPERTY AREA II �3/4� �z / I � F1 1 y F Al IRRIGATION LEGEND SYM MANUFACTURER & MODEL PSI GPM RAID. DETAIL REMARKS NOT SHOWN RAINBIRD XERI-BUG EMITTER 30 5,10,20 GPH 0 J 1/SHRUB (NOT SHOWN FOR FOR CLARITY RAINBIRD XB-05PC-1032 EMITTER FOR LOW WATER USE PLANTS. CLARITY. SEE PLANTING PANS RAINBIRD XB-10PC-1032 EMITTER FOR MOD WATER USE PLANTS. FOR LOCATIONS AND RAINBIRD XB-20PC-1032 EMITTER FOR HIGH WATER USE PLANTS & ANNUAL COLOR. QUANTITIES.) USE BII XERI-BUBBLER 30 .2 GPM 0 J 1 PER POT POTXB-360-1032 X ER 30 .5 GPM 0 I, N 2/TREE USE RAINBIIRD RD RWSBB C-1402 ROOT WATERING SYSTEM IN AWN AREAS RAINBIRD PEB SERIES VALVE (SIZE PER PLAN) C F • RAINBIRD XCZ-LF-100-PRF CONTROL ZONE KIT (SIZE PER PLAN) [ API FCH-H-FHT SELF FLUSHING END VALVE Q RAINBIRD 33DRC CUICK-COUPLING VALVE RAINBIRD ESP MODULAR CONTROLLER WITH ET MANAGER CARTRIDGE. USE ESP-SM3 EXPANSION MODULES FOR ADDITIONAL STATIONS. �r J EXISTING 1-1/2" WATER METER AND 2" BACKFLOW PREVENTOR. #1310722 MAINLINE: 1-1/2" PIPE AND SMALLER USE SCH 40 PVC PIPE, 2" - 3-1/2" PIPE USE CLASS 315 PVC PIPE WITH DEEP SOCKET SCH 40 FITTINGS 4" PIPE AND LARGER USE RING TITE PVC PIPE WITH DUCTILE IRON FITTINGS AND THRUST BLOCK / KICKER PER MANUFACTURER'S RECOMMENDATIONS. SLEEVING SCH. 40 PVC PIPE - 2 TIMES IRRIG. PIPE. IRRIGATION WIRING TO BE SLEEVED SEPARATELY FROM IRRIGATION LINES. LATERAL LINES CLASS 200 PVC PIPE A10 VALVE STATION 1� 27 GPM L VALVE SIZE NOTES: 1. THESE PLANS ARE DIAGRAMATIC. 2. MAINLINE AND VALVES ARE SHOWN IN HARDSCAPE FOR CLARITY ONLY. 3. IRRIGATION CONTRACTOR TO INSTALL RAINBIRD PRS BODIES ON ALL HEADS ADJACENT TO HARDSCAPE. E ti B Water Use Calculations Water Use Calculations Water Use Calculations Water Use Calculations Ironwood Mariposa I Irontree Comers - Ironwood Mariposa I Irontree Corners Ironwood Mariposa I Irontree Corners Ironwood Mariposa I Irontree Corners POC D ROC C POC B ROO A Site Information Site Information Site Information Si[e Information Zone No 1 Zone No i Zone No 1 Zane No 1 footage 1920 54 Total Tree and Scrub $Ware footage 208E Total Tree and Shmb Square footage 1]68 Total Tree and Shrub Square g Total Tree and Shrub Square rootage 20 Total Lave Square footage 9 Total Lewis Square footage 0 Total Lawn Square footage 0 Total Lawn Square footage 0 Total Annual Color Square footage 27 Total Annual Color Square loctage 2] Total Annual Color Square footage 27 Total Annual Color Square footage 27 Total Water festlre Square footage D Total Water feature Square footage 0 Total Water feature Square footage 0 Total Water feature Square footage 0 Recreational Turf Square footage 0 Recreational Turf Square footage 0 Recreational Turf Square footage 0 Recreational Turf Square footage D Number of olantsb water use %of Total Landscape Square Footage Number of claimsb water use %of Total Landscape Square Footage Numberofislantsby wateruse % of Total Landscape Square Focente Numberof iants ev water use %of Total Landscape Square Footage Very Low 0 0.01]0 000 Very Law 0 O. DOD 0.00 Very Low 'D' 0.000 0.00 Very Low 0 D.000 0 W Low 49 0875 182825 Low St 0.971 1610.14 Law 60 0.909 1745.45 Low 49 0.907 1863.81 Mod - 7 0.125 26075 Mad 5 0.089 157.86 Mod 5 0.091 174- Mod 5 0.093 190.19 H :0 : 0. SOD 0.00 High 6 0.000 0.00 High 0 000D 0.00 High 0 O.WO 0.00 Tot9 56 LDO Total 56 1.00 Total 55 1.00 Total 54 1.W Maximum Applied Water Allowance Maximum Applied Water Allowance Maximum Applied Water Allowance Maximum Applied Water Allowance Water Adl. Total Sq. Cra wnnuun Factors Water Atlj. Total Sq. Conwrsion Factors Water Atlj. Total Sq. Cornersion Factors Water Adj. Total Sq. Conversion Factors Zane No. Eta MAWA Zone No. Ere MAWA Zara No. Eta MAWA Zone No. Eta MAWA Factor Ft 062 748 Factor FL 062 748 Factor FL 0.62 748 Factor Ft 0.62 ]48 CorneMiora CorneMional Cowen imal Conventional 1 SZOi OS 2113 062 748 4992 1 57.01 0.5 1795 0.62 748 4241 1 57.01 0.5 1947 062 J48 46.00 1 57.01 0.5 2081 0.62 748 49.17 La^�dscape Landscape Landscape Landscape TOTAL MAWA 49.52 TOTAL MAWA 42.41 TOTAL MAWA 46.00 TOTAL MAWA 49.1J Estimated Water Use Estimated Water Use Estlrtla[ed Water Use Estimated st Water Use Area Seasonal Plant Factor: Plant Factor: OritsI ri blerSstemT e: Zone Itf. Eff. 'anon System e: Zone Inn' naIPIaMFactor: Plantllrtigation System Type: Zone urn. ER. Area Seasonal Plant Factor: Plantllrrfga[ion System Type: Zone Irr. Eff. Area Seasonal g y YP PlanVlmg Sy Type: Ltt. Area Seasonal 1 Mo-.n ce.e., 1 n a aaA aR 1) I n oe 1 M:�rn c.rw t n a tarn to 9-L.. Drio I Bubblerl Micro Sorav 1 9,9 1745.45 2 Low pdn I Bubbler I Micro Sorav 1 -0.si 1a6381 2 Low Season Zonal eo Ram Factor Area sq. fit Converson Factors 062 748 un HtSpring 12.54 020 182525 062 748 093477 020 182525 062 7aB 0.9Fan-Winter ff�t�t�jValue 9.70 0.20 182525 062 748 09TOTAL Season Zonal 90 Value Fact Farrar F a,- ice Factors 062 7a8 Yn.HLarng 12.54 0.20 062 748 09 dAoa 052 748 09Fan-writer 9.70 0.20 0.62 748 0.9n2,89 TOTAL Season Zonal Bo V¢lue Ran( Factor Lbnvers an FeUors BOrated Wotan We 062 748 in. BL Stan, 12.54 0.20 a.62 746 09 403Summer Sol 77 020 bAas 09 11.18 Fat -Winter 970 020 062 748 0.9 3.12 TOTAL 18.33 Season Zona Es. Value Pam Fro Pow Area sq. tt Conversion Factors Btlremad Water We 0.6 148 in HL Spr,q 12.59 020 1883.81 062 748 09 4.31 Surrmar 34. 77 020 1863.81 0.62 7ae 09 11.94 Fan-VWller 970 0.20 1853.81 06' 748 1 0,91 3.33 TOTAL I 1 1 19.57 Plant(whigaHon System Type: Zone Irr. Eff. Area Seasonal Plant Factor: Plantlinigation System Type: Zone Irr. Eff. Area Seasonal Plant Factor: Plantllrrigation System Type: Zone Irr. C-ff. Area Seasonal Plant Factor: PlanHlrrigation System Type: Zone Irr. ER. Area Seasonal Plant Factor: Drip 1 Bubbler I Micro Sorav 1 0.9 26075 3 Mod Drio I Bubbler I Micro Sorav 1 0.9. 157.86 3 Mod Drip I Bubbler I Micro Spray 1 0.9 174.55 3 Mod Drio I Bubbler I Micro Sorav 1 0.9 190.19 3 Mod Season Zonal Ho Valve Paul Factor Area sq.R Conversion Factors Esfinete] Water Use 082 748 Yn. Ht spring 1254 0.50 260]5 062 749 09 1.51 surmrrer 34]7 0.50 260]5 062 74e 0.9 4.11 Fall-Vusntar 970 0.50 260.75 062 7ae 09 1.1E TOTAL 6.85 Season Zonal do Value Pant Factor Area sq. ft Conversion Faclaw Blended Winer lke 0.62 748 Yri. Ht Screw 12. 54 O.W 157.8E 062 748 09 0.91 smr me 3477 0.50 157,861 062 1 748 0.9 2.53 Fall Writer 970 0.50 157,Wl 062 1 748 1 0.9 0.71 TOTALI 1 1 4.14 Season Zonate. Value Ram Factor Area sq. fl. Conveys - Farm , Encased water Use ti 7a6 U(Hf. Sprig 12.54 0.50 174.55 062 748 0.9 1.01 somter 34.77 0.50 174.55 0.52 748 0.9 2.79 Fan Winter 9.70 0.50 174.55 oaz 74e 0.9 078 TOTAL 4.58 Season Zonal Ho VaWe Ran, Factor Area Conversionini a Because Water Use Ini. Hf. spy rig 1254 0.50 0.9 1.10 stunner 34.77 0.50 M 09 3C5 Fall -Willer 970 060 0.9 085 TOTAL 4.99 Plandirrigation System Type: Zone Irr. Eff. Area Seasonal Plant Factor: Plantllrigation System Type: Zone Irr. Eff. Area Seasonal Plant Factor: Plantllrrigabon System Type: Zone Irr. Eff. Area Seasonal Plant Facto: Plantlimigation system Type: Zone Irr. Eff. Area Seasonal Plant Factor: e-- 1 n g a Hinb .. co-, 1 n a 7 he 4 High Orin I Bubbler I Micro Sorav t a.9 2].90 4 High hn: 1 Rrmbb. I aamm Sorav 1 0 a 1 97 na 4 Him Season Zonal Ho Value Pan, Facto Area sq. ft conversion Factors BLrmled Water Use 062 ]48 M.@C Swing 12.54 0.80 2700 062 748 0.9 0.25 Summer 34]7 0.80 27.00 662 74; 0.9 0.69 Fail-Wtnter 9.70 Cell) 27.00 062 1 748 1 091 0.19 TOTAL 3 Estimated Total Water Use 27.15 0 Q� NORTH KEY MAP NOTE: Season Zonal Bo Value RaM Factor Area sqfL Conversion Fantors EstlrtMee Wafer n'! 082 Spun, 12.54 0.8D 27 M 082 74B 0.9 025 Sumrer 34.77 0.80 27.60 a62 7ae D.9 069 Fall -winter 9.70 0.80 27.W 062 1 748 1 0.9 0.19 TOTAL 1.13 Estimated Total Water Use 22.19 TREES, PLANT, WALLS, SIDEWALKS AND PERMANENT STRUCTURES OF ANY KIND SHALL NOT BE PLANTED, INSTALLED OR BUILT IN CVWD AND USSR EASEMENT OR RIGHT-OF-WAY WITHOUT FIRST OBTAINING AN ENCROACHMENT FROM CVWD. 0c Season Zonal aotFiscors, Value Ron, Area sq. fl. converson Factors Finessed Water Use 0.62 748 in HI. Spring 12.54.80 27.00 062 748 0.9 025 Sumter 347780 2700 062 748 09 D69 Fall-lMma,970.80 27.00 062 7ae 0.9 0.19 TOTAL 1.13 Estimated Total Water Use 24.05 O O KEYNOTE: EXTEND EXISTING HOA #6 MAINLINE AND CONTROLLER WIRES TO SERVICE CORNER IRRIGATION VALVES. Q2 EXTEND EXISTING HOA #8 MAINLINE AND CONTROLLER WIRES TO SERVICE CORNER IRRIGATION VALVES. 4 EXTEND EXISTING CLUB MAINLINE AND CONTROLLER WIRES TO SERVICE CORNER IRRIGATION VALVES. ® EXTEND EXISTING HOA #13 MAINLINE AND CONTROLLER WIRES TO SERVICE CORNER IRRIGATION VALVES. Season Zonal Ho Value Pant Factor Area sq.n Cora, 1pn Pines, so Water the 05, 7q8Factors in91. spring 1254 0.80 27.00 0.62 746 09 0.25 Sumner 34.7] 0.80 27.00 0.62 74a 0.9 0.65 Fall Wine, 9]p 0.80 27. Jul o.52 7ae 09 0.19 TOTAL 13 Estimated Total Water Use 25.70 SCALE: 1'=20' GRAPHIC SCALE tt30' 40' 2a 10' O CVWD LANDSCAPE APPROVAL These plans have been reviewed by the "Chella Valley Water District in .} R T EFR accordance with Water Code Title 7, Chapter 3, Article 10.8, Section 65597 et seq. requiring efficient landscape and irrigation design in cooperation With the local governing agency (City or County). Approval of {} T R t C_r this drawing by CVWD staff does not constitute approval to encroach Into district and USSR Righis-of-Way. Trees, plans, walls and permanent Structures of any kind may net be planted or Installed in CVWD and USHR easements or right -of way without f[irSt obtaining an er-machrnent permit from CVVi fill f2, Wo A ate ER M GFM,, NT SUR VISOR CVWD Plan 9 EVELOPME6C°SEA ICES SUPERVISOR LANDSCAPE ARCHn-ECTS, INC. 74020 ALESSANDRO, SUITE E PALM DESERT, CA 92260 (760)568-3624 FAX (760) 773-56Z E-MAIL: RGA•RGA-PD.COM a: W Z O U W W a Z I- Q ZU Z CO W 0 � � Q � � aQ 0. Q O O Z O W U W 7 _ � C0 CL SPECIFICATIONS SHEET ❑ BOOK JOB CAPTAIN: RP DRAWN: TM CHECKED: PROD. NO: R 0812 DATE: 5/5/10 SCALE: 1• = 20'-Ow REVISIONS: SHEET NO: IP-1 L39105 BRASS NIPPLE (TYP) 4 PLACES GATE VALVE REDUCED PREP BACKFLOW PREVENETER GATE VALVE TEST COCK ITYPJ 4 PLACES STRAIT{ #40 $rah MESH MON EL —� q APPLE EWi(OR EOUALJI )rM PLASTIC BOX + COVER W/ LOCK TOP MANYED IRRIGATION CONTROL VALVE COLOR TO MATCH SURROUNDING BOX TO BE PLACED SOL USE LAVENDER BOX FOR RECLAIMED WATER AT RIGHT ANGLES APPLICATION. TO HARDSCAPE EDC E VALVE SEOUBdCE TO BE PANTED ON d EACH BOX Mal$ - *_ R__; F • PE EXPAW OP(MIN24') APPLED ENG. (OR EOUAL) ROUND PLASTIC BOX + COVER COLOR TO MATCH SURROUNDING 801- RAN N DA AND (iFEE N N LAVIM USE LAVENDER BOX FOR RECLALIED WATER APPLICATION �x x x x %� xxxx�%xxx x% x /}i x x x x x x x (itk� x x x �x x x x x x x x ' \,x x x x / FLASH GRADE LAWN AREAS FNSH GRADE SHRUB AREA :• COVER COLOR • MATCH SLIFIROUNDNG SOL USE LAVENDER BOX FOR RECLAIMED WATER APPLICATION. PEDISTAL 1 BRASS ELBOW MOUNT FINISH GRADE NON PRESSURE LINE LAWN AREAS FITTING HANDLE PVC LIE PPE 4' THREADED NIPPLE RELIEFPORT SOLENOID IT x FISH GRADE SHRUB AREAS O ; . • ' . PRESSURE SUPPLY ELL LINE (SEE SPEC) s . e . y�•w ^^• • ►^e R ` e' FLOW ADRJ8TM3fi =!. 1 STREET ELL PEA GRAVEL `� STREET ELL BRASS ELBOW FLOW FNISFi gpADe };•" ;b` ~ (MIN. 3 CU. FTJ PEA GRAVEL GAN2 CU. FTJ TEE (TMr1EADED OUiLEh ° 1 PVC SCE. 40 MALE . • 12' THREADED NIPPLEPREESURE ` aPRESSURE SUPPLY LINE FITTING s (SEE SPECHCA TK)NI) ",; BALL VALVE LINE INTAKEd IIBE TAE NIPPLE A PVC LIE PPE MNSCH 80 CONTROL WIRE EOUPCOMMON WIRE OUI ' I MENT TO BE INSTALLED AT A MINIMUM OF 1Y FROM WALLS, �..• .,, � �:: f ..- . BU-DNGB, ETC- NOTE 2 ALL ABOVE GROUND ASSEMBLY SHALL RECEIVE ONEM COAT Y PVC SCH 40 CONDUIT INSTALL CONTROL VALVES MINIMUM OF 3F7. APART RED LEAD PRIMER AND ONEW COAT PANT AS SELECTED BY AND FITTINGS TTINGS N SHRUB AREAS UNLESS OTHERWISE NOTED. ARCHITECT 3. WHEN UNIT IR NEXT TO BUMm WALL, ETC, TEST COCKS ARE TO BE ON OUTSIDE A BACKFLOW PREVENTOR (PER C.V.W.D.) B AUTOMATIC CONTROLLER C AUTOMATIC VALVE D FULL PORTED BALL VALVE E QUICK COUPLER VALVE APPLIED ENG.(OR EOUAL)12'KW PLASTIC BOX + COVER W/ LOCK TOP MARKED IRRIGATION CONTROL VALVE. COLOR TO MATCH SURROUNDING SOIL USE LAVENDER BOX FOR RECLAIMED WATER APPLICATION. / 1 VALVE SEOUENCE TO BE HEAT BRANDED ON LID OF EACH BOX FINISH GRADE USE CHPoSTY'S TAGS OR EOUAL EQUIVALENT TO INDICATE VALVE SEQUENCE ON VALVE CONTROL ZONE KIT: RAIN BIRD XCZ-100-B-COM (INCLUDES BALL VALVE,10OPESB VALVE, OKCHK100 BASKET FILTER AND PSI-M40X-100 PRESSURE REGULATOR) PEA GRAVEL I BUBBLER HEAD Y—FILTER RCV i PRESSURE REGULATOR N PLANTING LEGEND GENERAL INSTALLATION NOTES I SPRNCL ER IRRIGATION PLAN IB DIAGRAMMATIC. FINAL LOCATION OF PIPING WILL BE DETERMINED ED AT TIME OF INSTALLATION. MAINLINE AND LATERALS SHALL BE PLACED N SAME TRENCH WHEN POSSIBLE ECUPM@!T SHOWN N PAVED AREAS IS FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED N PLANTED AREAS 2 INSTALL ALL EOIPMBQT AB SHOWN N DETAILS. ALL EGUPMENT PEOIRiED BUT NOT SPECF® ON THE DRAWING SHALL BE PROVIDED BY THE IRRIGATION CONTRACTOR 3, ALL EQUIPMENT SHALL BE NSTALLED N ACCORDANCE WITH MANU°ACTUREITS INSTRUCTIONS AND SPECIFICATION& 4. BACKFLOW PROTECTION UNFr(8) SHALL BE INSTALLED N ACCORDANCE WITH LOCAL CODES. §. IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER WORKMANSHIP DURING INSTALLATION. 6 ALL MAN1E PIPING SHALL HAVE A MINIMUM OF lir COVER (24' UNDER ROADS AND STREETS. AND 24• F RUBBER FROG SEALED PM. ALL LATERAL PIPING SHALL BE TRENCHED A MINIMUM OF IV DEEP. ALL CONTROL WIRE GONG UNDER DRIVEWAYS AND STFETE SHALL- BE SLEEVED N A PVC PPE LATERAL PIPING GONG UNDER DRIVEWAYS AND STREETS SHALL BE SCHEDULE 40 PVC. 7, ALL VALVE CONTROL- WIRE SHALL BE INSTALLED N SAME TRENCH WITH MAINLINE WI-IEREEVE R POSSIBLE AND SHALL BE SOLD COMM AWG 014, TYPE IF DIRECT BURIAL WFF_ UEM SNIAPTITE OR SCOTCH-LGC WIRE CONNECTORS. 8. ALL TRENCH SACKFLL SOIL SHALL BE CLEAN, FREE CF ROCKS, TRASH{ GLASS, SOLVENT AND CEMENT CONTAHBiS AND RAGE. CONTRACTOR SHALL COMPACT ALL TFE ACHES TO A DENSITY EOUAL TO THE LraxnWEIED SOIL AND SHALL BE FEBPONBBLE FOR 8FE40M ANY SETTLED TRENCHES BACK TO FINISH GRADE 9. CONTRACTOR SHALL FLUSH ALL PPE LIES PRIOR TO INSTALLING SPRINKLER KNEADS, 10. CONTRACTOR SHALL NSrALL VALVE BoxEs AT GRADE OVER ALL E LEOW90 VALVES AND INSTALL ANTFIXIAN VALVES AS NECESSARY TO PREVENT LOW READ DRAINAGE EROSION OR DAMAGE iL CONTRACTOR SHALL ADJUST ALL SPRNCLEw AND VALVES FOR PROPER OPERATION AND COVERAGE fPFRi(LERS ALONG STREET CIRBMG AND DRIVEWAYS SHALL BE SET BACK 15 P40 EHB PER CVWD. ALL SPRINKLERS SHALL BE ADJUSTED 80 THAT NO WATER IS T}IR01MN ONTO STRUCTURES OR NATURAL FACED MASOIW WALLS, NO OVERTHROW ROW IB PER MfrTED ON HARDBCAPE 2 120 VOLT POWER FOR CONTROLUER(S) B TO BE PROVIDED BY OTF6i8 ON A SEPARATE CIRCUIT BRIBAKERL IRRIGATION CONTRACTOR SHALL BE RESPONBEILE FOR MAKING CONNECTIONS TO CONTROLL.EFR. CONTROLLER FINAL LOCATION SHALL BE DETERMINED BY OWNERS AUTHOR® REP ESENTATIVE- 13 RONALD OFE 1ORY ASSOCIATES, NC. SHALL APPROVE ALL INFIELD DESIGN CHANGES DUE TO SITE PLAN AND LANDSCAPE PLAN CHANGES TO GUARANTEE =% SPFM*QJ i COVERAGE OR THE FIRIOATION CONTRACTOR SHALL ASSUME FULL fISSPON91911 Y. 14, RONALD GFEGORY ASSOCIATES, NO. SHALL NOT BE RESPONSIBLE FOR IMPROPER OPERATION OF SYBTEW DUE TO CONTRACTOR NOT FOLLOWING PLAN PPE SANG OR NADEOUATE STATIC PRESSURE OR INFIELD DESIGN CHANGES WITHOUT APPROVAL 15 RONALD GREGORY ASSOCIATES, INC.18 NOT RESPONSIBLE FOR EFIRI N INSTALLATION F THEY HAVE NOT BEEN RETAINED FOR INSTALLATION OBSERVATION. 16. LANDSCAPE CONTRACTOR SHALL REFER TO SPECgCAT10N8 FOR DETAILS, STANDARDS OF MATERIALS AND WORKMANBFP. SPECIAL NOTES t E O E OTHER AREA WHERE THEY A Ek7 To AA WALRUSL, , A FENCEY HEADS ON A RISER WILL ONLY BE CLEAR VIEW AN APPROPRIATE HEIGHT PROP -UP SPRINKLER SHALL BE INSTALLED ADJACENT TO ALL WALKS, DRIVES. PATIO AREAS AND ALL AREAS PEDESTRIAN TRAF Fk-_ FINAL INSTALLATION N LAWN SHALL BE FLUSH AND N aHmm BEDS ONE INCH ABOVE GRADE - CONTRACTOR SHALL PROVIDE THREE BUBBLERS AT THE ®ORE OF THE ROOT BALL FOR EACH FELD GROWN OR 24' AND LAROE3R BO) EID TRFSE OR AND OTHER TREE AT THE DIRECTION OF THE LANDSCAPE ARCHITECT, POP-UP SPRAY SPECIFICATIONS LAWN TWO OR THREE NCH POP-UP BODY N STANDARD TURF OROUNDCOVE i THREE OR FOUR NCH POP-UP BODY FOR LOW GROWING TYPES, FOUR OR SIX NCH POP-UP FOR TALLER TYPES. ANNUAL COLOR SIX OR TWELVE NCH POP-UP BODY SHRUBBERY SIX OR TWELVE NCH POP-UP BODY 1:: 1 KEYNOTES 2 1. HARDSCAPE (TYP)/FINISH GRADE W2. CLEAN BACKFILL - 90% COMPACTION 3 12• 3. SAND (TYP) 4 4. NON -PRESSURE LATERAL LINE SLEEVE (SIZE PER ';t•'';.'.`::•=•.' CHART)/NON PRESSURE LATERAL 60 6 5. PRESSURE MAINLINE SLEEVE (SIZE PER CHART)/PRESSURE MAINLINE I h_ 6. CONTROL WIRE SLEEVE ADJACENT TO MAINLINE 2' SLEEVE. ALL SLEEVES TO BE SCH 40 PVC. EXTEND SLEEVES 12" BEYOND EDGE OF HARDSCAPE ON 6 BOTH ENDS. RECLAIMED WATER SLEEVES TO BE 2' 4 e 5 2' MINIMUM 42"-48" DEEP ( OR PER WATER DISTRICT SECTION / ELEVATION STANDARDS WHERE APPLICABLE). % COMPACTION REQUIRED - SEE SPECS O TRENCHING/SLEEVING DETAIL LEGEND t RAW BIRD XERI-SPRAY OR XERI-BUBBLER OR XER-BUGI EMS" DEVICE (SEE FIFIGATION K DRIP VALVE EMITTER PIPE SIZING CHART 1/2" PIPE 0 TO 180 GPH 3/4" PIPE 181 TO 360 GPH 1" PIPE 361 TO 840 GPH IRRIGATION HEAD TYP. (SEE IRRIGATION TREE, PALM TRUNK ROOT BAIL �® ' (C EOUPIMBdi LEGEND FOR MODEL f). �� BOX + COVER COLOR TO MATCH 1-1/4" PIPE 841 TO 1440 GPH LEGEND FOR SPECS) FINISH GRADE INSTALL AT LOWEST POINT � 30L 2 RAW BIRD MODEL #PFR/FRA24 POLY FLEX RI8Ei AND/OR AT END OF LATERAL USE LAVENDER BOX FOR RECLAIMED USE L ENDE B Xr L \ 4-�TM'N'S )• PIPING A8 �®' 1. INSTALL ONE EMITTER PER PLANT (UNLESS OTHERWISE NOTED) AT UP 3. D.G. OR MULCH BED' I Q 4 . a I I I ITS I HILL SIDE OF EACH PLANT. / 71 FINISH GRADE ! L a' a 4. FINISH GRADE _ I I d —� �I I I: I < a Tom;' l- 2. DUE TO THE HIGH QUANTITIES OF EMITTERS, ALL EMITTERS ARE NOT SEE DETAIL (THIS SHEET) SHOWN ON PLAN. IT SHALL BE THE IRRIGATION CONTRACTORS FOR BUBBLER OR S PVC RITW IS x S x 1/2' FPT). PVC LATERAL L _I I ° A a, -111 RESPONSIBILITY TO CONSULT WITH LANDSCAPE ARCHITECT TO OBTAIN XERI-BUBBLER DETAIL SEE PLAN FOR WE THE ACTUAL NUMBER OF PLANTS FOR THE PROJECT. 6. PVC PPE DEPTH PER SPECFICATi0N3). I I c AP. Ci FCH _ — PLACE IRRIGATION HEAD PLACE IRRIGATION HEAD AUTOMATIC FLUSHING BIND VALVE 3. IT SHALL BE THE IRRIGATION CONTRACTOR'S RESPONSIBILITY TO AT EDGE OF PLANT PIT. ADJACENT TO ROOT BALL NOS` FILL BOX WITH 1/2' PEA GRAVEL ACCURATELY PIPE SIZE ALL EMITTER PIPE SIZE CHART SHOWN ON PLANS. PLACE E MTrnM AT EDGE OF PLANT ROOTBALL J DRIP EMITTER I L AUTOMATIC SELF FLUSHING END VALVE M TYPICAL EMITTER LAYOUT DETAIL N TYPICAL TREE/PALM IRRIGATION DETAIL CVWD LANDSCAPE APPROVAL These plans have been reviewed by the Coachella Valley Water District in Q)18 accordance with Water Code Title 7, Chapter 3, Article 10.8, Section65597 et seq. requiring e�cient landscape and irrigation design in cooperation with the local governing agency (City or County). Approval df this drawing by CVWR� staff does not c:onslltute approval to encroach into R 5 C district and USBR RILNhLs of --Way. Trees, plans, walls, and permanent structures Of any kind may riot be planted or Installed in CVWD and USBR easements or right -of -Way without first obtaining an encroachment permit from CVWO. ate ER M CEMENT SUP VISOR CVWD Plan DEVELOPM,EAf SE 1C SS SUPERVIS R LANDSCAPE ARCHITECTS, INC. 74020 ALESSANDRO, SUITE E PALM DESERT, CA 92260 (760) 568-3624 FAX (760) 773-5615 E-MAIL: RGA*RGA-PD.COM I.L W z I=/ 0 0 W CO W J � a Q Z U W � W Cl)LU Z 'A 00 O a- 5 Q MMMMM� a: p 0 Z 0 W J U ILL ILI 7 2 ir SPECIFICATIONS SHEET ❑ BOOK JOB CAPTAIN: RP DRAWN: TM CHECKED: PROD. NO: R0812 DATE: 5/5/10 SCALE: 1" - 20'-0" REVISIONS: ,&PER CVWDCOMMIF T 0 SHEET NO: IP-2 I s■ LL I M 1 • 1� 'Al = Doo D��Q�p 0 DOB tO b°tlbb DDp DC6 D D p oo Qrp� �' Q, � p0 o °� 0 ° d 0 �00 0 pp 0 a. 0 �y D lyNoBa a OOD 0 D Dq6%D � W_) p 0 01,�00-o/ g O O 4 Q�*i 1 'Not ODOOpO� D D D 0 o� a o� Ds T a cxiJCl oQ°J�600'`p(� 9 D°°�0y0° ° ° Ooo 0 Oo�/ 00 o g0 �O o� ° 00 oo °oho 0 10 0 0 0 0 (Q O 0 ° BUILDING fPLANT SLK*iiLY ABOVE SOT. LEVEL v pd � cur oP sECTION OF 0 0 0 000 o �°� � O o0� ° '' o �0 8� o � �o�o�o ��p,Oq 0 �8°� 0 g' �9b��° oo A°°° PLANT PIT DEPTH OF ROOT BALL KEEP 80L MOIST, NOT WET i i i•' STAKE AKE A�A� 01 HAMMERING Q �QO V� � °O ° J�oo O � � !J o 0 D 061J" 8 00 0 0� o _D ° o o g o °So0 �� g � ° O��q� °�Q~)�S p� �o O D �U(6, co 6^°0 �o o Ooo S �B oPO � °°°� � N ES OR EOUAL � ,po ° o °o o ° 0 0 0 d' 60 ° 0 0 C140H TIES OR EOUALo0) 6 °o °�0pg0 �o �O 00 �oc,o °�a 0 D �tl 217- TRUNK AND POLE SNUG AROUND TRUNK °� °� � o " �° ° ° 0 ° 0 0 CABLE CLAMPS TREE °�°� O NATIVE SOL UNDISTURBEDNATIVE PR 2 TIRES DIA OF ROOT BALL 2' (2)-BY 2' BY 10 -0' REDWOOD STAKES OR LODGEPINE POL N012 GALVANIZED WIRE o����� oo ° % 001I �O �Xeo ��,, ° 0E TURNBUCKLES TO EOUALRE o0 �jg O"� w0 ROOT BALL AND MAINTAIN TAUTNESS OF WIRE F148H GRADE o R 4 WATER BASH Elm� WATER BASH S-W OR LESS 5-0' OR LESS FNBH GRADE N012 GALVANIZED WIRE O ALL NATIVE PLANTS SHALL — — t—t � WITH BE BACKFILlTH NATIVE SOIL ONLY ROOT BALL BACKFLL MDh _ t i I tT� , � � i / BACKFLL MUC: (SEE SPEC�a SEE SPECFICATKN�IB. I I I SEE SOILS REPORT FOR SOIL AMEI uENT REOUFEM84TS UNDISTURBED NATIVE SOL PLANT PIT AS UN IISTURB® SOL 2 T1 ROOT BALLAS ROOT B ALL SIDEWALK/PAVING FOR SUB TROPICAL PLANTS PLANT PR 2 TIMES AS WIDE AS ROOT BALL LFEAR ROOT BARRIER LB W2 BY 'DEEP ROOT' OR EQUAL INSTALL PLANT PIT AS DEEP AS ROOT BALL PER MANUFACTURERS SPECS. NOTE- AL TREES SHALL ONCE ESTABLISHED ON SOL3SRREPORT . (SEE SPECS) NOTED STAKE DETAIL ONLY APPLES NOTED Al TREES SHALL NOTE: ISA CERTFED ARBORIST ARE TO NBTALL FERTILIZER ONCE ESTABLISHED USING CURRENT USA STANDARDS ON ON SOILS REPORT (SEE SPECS) WFJN3 FOR TREES. GL M DETAIL ONLY NOTE, ROOT OU SHALL NOT BE INSTALLED ON TO STANDARD TRUNK TREES. AND ONLY AS NEEDED APPLES TO STANDARD TFNJNC TREES, AND ONLY AS NEEDED. IN PALM DESERT PER DIRECTIVE Or - CITY PALM DESERT LANDSCAPE MANAGER SHRUB PLANTING DETAIL DOUBLE STAKE TREE DETAIL TREE GUYING DETAIL ROOT BARRIER DETAIL 2,V BOX 34W BOX PLANTING NOTES COBBLE PLACEMENT. RANXILY AND LOOSELY MCC DFF6@R Ei TO SME COBBLES COBBLE TRANSTITON COBBLE Nlo DEOOAFOBED BOULDER t PLANTNO PLANS ARE DIAGRAMMATIC FOR cLARTTY OF FEAma PLANTNO S TO BE ADJUST®N FEW A8 NECESSARY. 2 PLANT OUANRTI' LJBT B PROIIDED FOR THE OONVB'6NCE OF THE GRANITE AREA CONTAOTMCL EM AND S NOT MEND® FOR ACCURATE BDDNO PURPOSES. \ ( FOR MATERIAL AND SIZES, SEE PLANT LEGEND) CONTRACTOR SHAD_ BE RESPONSIBLE FOR PROIMM PLANTS AS INDICATED ON THE PLANE S M0111ONO AND ROUCIfi O<RADE To 1/1D FT. TO BE PROVD® BY OTFER& FNBH fI 2 /3 GRAM TO BE PRoVEM By LANDSCAPE CONTRACTOR 00 GRADE 4. WHERE m m*n Come AwAcENr TO STREET OR WALKS. SWALEs SHALL BE FORMED ALONG THE SHEETOR WALK TO CONTROL imOATKNI RUN OFF. S BEFORE ANY PLANTS ARE LOCATE TE ALL PLANTED AREAS AM BE GRADED IN o' o AN ACCEPTABLE MANNER TO ASSURE POStTNE DRANAOE SEPARATE\�% AREAS WITH HORIZONTAL PLANE o Q 1/3 /�/jam/j \F� ��\/�/j�//j/%\' By TO AN EDGE OFCIRCUMST�PAVI a HE PEFUr �pARROR ROOF LINE. ANY M40 THAN P� WAUA CURBS�r PRUNE FRONDS BELOW 1 BELOW HOMONTAL PLANE PER USA STANDARD ` _ o O � sus GRADE NOTES: �� ROOT BNi6i 16TALLM AT TIME OF PLLAAMM PER MANUFACTURES BPECFK:AmoW EKCLUDlKL PROJECTS N PALM DESERT PER DN;ECTTVE OF CRY PALM DESERT LANDSCAPE MANAGER (SEE DETAIU & Do NOT PLANT 8-Rues m em THAN s CmFm FEM TO AN MOE of PAVNO OR r O HEADEDOAFD, OR So' FROM LANDSCAPE LIGHT FvruF $. - BURY BOULDER A MINIMUM OF 1/3 ITS HEIGHT BELOW GRADE. QL REMOVEErmmmKANm PROM THmTRAmmRw WOR Am ATTACH To BOULDER SIZES TO BEAPPROX.EOUALINALLDIRECTIONS. THE WALL AGANSTWHCHTFEYAREFLAMM ATTACH PLANTS NTHE SAME PATTERN THEY HAVE BEEN TRAINED. O - PLACE AS NEAR AS APPLICABLE TO PLAN, EXACT FINAL 1a F REOURM THE OWNER OR OWN IMS FeRESE TATM SHALL SU MT PLANE To THE TE�AR�ar AMAGPjMLTUREDEPARMMMPRIOR MSU1* TTAL LOCATION TO BE FIELD VERIFIED BY LANDSCAPE ARCHITECT. FOR BILDM PER MINT ttpBN� BAAC InIM THE RKbT BALL, WATER THE PLANT INTHE HOLE MD THEN J PROCEED WrIH BAciagLUNa COBBLE LAYOUT / DETAIL BOULDER DETAIL UC+MNG NOTES t ALL WOW AND MATERIALS SHAI - OORFOR M To LOCAL CODES AND ARE SUBJECT TO APPROVAL BY THE LANDSCAPE ARCHRECr OR OTHER FEPfEBEtTATNE OF OWNER 2 ALL LKRHT FWTUE LOCATICW ARE SHOWN DIAGRAMMATICALLY ON THIS PLAN ACTUAL LOCATIONS SHALL BE OETER TAM N THE FED AND APPROV® BY THE LANDSCAPE ARCHITECT AFTER TREES HAVE BEEN PLANTBI & 0uA(ITTE6 LISTED ARE FOR THE OONvewcE of THE CONTRACTOR ONLY AND ARE NOT M@D® FOR ACCURATE emm USE CONTRACTOR B RESPONSIBLE —' FOR PROVIOM UGINT AB NDCATED ON THE PLANE. 4. ALL LMHT FDRIIES SHALL BE LOCATED AT A NW N OF 6 piVE FEET) FROM POOL, SPA, LAKE OR FOUNTAIN EDGE ALL LKINTS WHICH ARE N6TALLED WREN V M FEED OF WATERS EDOE To HAVE OR -- S !STALL CONVENIENCE OUTLETS AS LAW AS LOCAL CODES PERMIT: E, INSTALL BFCTRCAL CONDUIT TO THE EDGE OF PL.ANTNO ARREB 80 AS NOT TO INTHiFBE WITH PLANT HOLE EXCAVATDN Comm N THE WAY of THREE TAMP +WATER- HOLES SHALL BE RELOCATED AT NO EXTRA CHARGE. BE LOCAIM No CLOSER THAN s' (eoc Nam FROM MOE a WHILE PLANTING THE PAVN0 A LAWN S. INSTALL PHOTOELECTRIC SWITCH WRH TlMM SHUT-OFF. MANUAL OVBRROE BOULDER SWITCH TO BE LOCATED PRIOR M f BTALLATDN COORDINATE LOCATION OF Bwnx*BS WITH OWNER \ i GOBBLE IN DET'RESSED GRADE & ALL LIGHT F DOLRES TO BE INSTALLED PER MAN FACiUFMTS BPECFICATKON& 10 MOUNT FD TUREB AS LOW AS POSSIBLE; SCREEN OIVF6E POSE" WITH PL.ANTINM GRADE �� FINISH GRADE iL ALL CONDUIT TO BE SCH 40 PVC WITH OALVAiZM go FOWS ULE BELL BP. GA.VANLiED STEEL LL LISTED EXTERIOR BELOW GRADE jmcnON Bo>o� OR As PER NEC BPECF1MT1(*a M ALL CIRCUITNQ swm- O BE BYE ECTRICAL N1G AND OON ECTIONSTL OCATKONB ONLY AND B NOT onov/110 M@D® M BE AN ELECTRICAL PLAN. CVWD LANDSCAPE APPROVAL E�s BOOK Thane plans have beet) toot -wed by the Crischolia valley Water District in � t, T E q accordance with VVoter Coft Tttle 7, Chap#ar o„ AMde 10.8, Section 6569E at seq. requiring efficient t landscape add krigation design in cooperation With the kxal governing agency (City or County)Approval of SEE K�iT PALM UNDISTURBED NATIVE SOIL ROOT BALL FINISH GRADE SWALE '� T � � � "..` : SLJB GRADE C3 NOTES: than drawing by CVWD staA does not constitute appsava: to anctoach Eroo #S G 2 X DIA io o a oo D o 0 - � C - -,_ - BURY BOULDER A MINIMUM OF 1/3 ITS HEIGHT BELOW GRADE. F H t district and USSR Rlghbt -Way. Trees, plans, walls, and permanent structures otarnykn�rVV dmaynotbeplantedorinstaiHOInCIDoneJUSSR OF ROOT BALL — — — —_ _ — _ -- — —�— -BOULDER SIZES TO BE APPROX. EQUAL IN ALL DIRECTIONS. aawmentsorrighs-ol-WeYwlthLfat obtaintnVantaaGhrnentpermil fromcvwt). - PLACE AS NEAR AS APPLICABLE TO PLAN. FINAL LOCATION NATIVE SOL TO BE FIELD VERIFIED BY LANDSCAPE ARCHITECT. U ALM TREE DETAIL COBBLE DETAIL BOULDER AND COBBLE SWALE DETAIL I t Ql#N RWES LXV I LANDSCAPE ARCHITECTS, INC. 74020 ALESSANDRO, SUrrE E PALM DESERT, CA 92260 (760) 568-3624 FAX (760) 773-5615 E-MAIL- RGA•RGA-PD.COM cri Z crM 0 0 W J ~ U Q � w W �w VJ V CO 00 Z (L � �- a J Z � � Q J 0 O Z L� L U 2 Q (L SPECIFICATIONS SHEET ❑ BOOK ■ JOB CAPTAIN- RP DRAWN- TM CHECKED- PROD. NO: R 0812 DATE- 5/5/10 SCALE- NYS REVISIONS- 0 0 SHEET NO: PL-2 i NOTE: REFER TO CITY OF PALM DESERT MAINTENANCE GUIDE. City of Palm Desert Landscape Inspection Schedule 1) Sleeving / Grading a. Sleeve diameter, type, depth and location b. Soil surface drainage, elevations and trash (including weeds & rubble) 2) Hardscape / Boulders -Cobble a. Sidewalk and wall layout b. Utilities location c. Boulder type, size, weight and placement 3) Irrigation System Rough -In a. Trench depth and location b. Pipe size and class c. Pressure test (125 psi for 6 hours) 4) Plant Material (trees & shrubs) a. Condition b. Type c. Placement 5) Ground Cover (decomposed granite) a. Type b. Depth and spacing c. Compaction 6) Final a. Irrigation: i) Valves, boxes and wiring ii) Controller operation and schedule iii) Sprinkler, bubbler and/or drip emitter type, flow rate and quantity per plant iv) Overall operation v) As built b. Tree staking c. Overall v) As built b. Tree staking c. Overall Irrigation Water Use Schedule by Month (This irrigation schedule is a guide per CVWD) Spray Heads Bubblers and Emitters Lawn irrigation days per weelc by month Tree + shrub irrigation days per week, by month Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct Nov. Dec. Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. 2 3 4 5 6 7 7 6 6 4 2 2 2 3 4 5 6 7 7 6 5 4 3 2 Spray ype head for lawn (in minutes per irrigation day). by month Bubbler type head for trees (in minutes per irrigation day), by month Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct Nov. Dec. Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. 3 5 8 10 10 10 10 10 8 6 7 2 Low. 10 16 20 28 36 40 42 34 30 20 14 8 Rotating_tvpe head for lawn (in minutes per irrigation day), by month Emitter type head for shrubs (in minutes per irrigation day), by month Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. Jan. Feb. Mar. Apr. May June July Aug. Sep. Oct. Nov. Dec. 12 22 35 42 46 41 41 40 32 27 28 9 Low. 12 18 24 36 42 48 48 42 36 24 18 12 Contractor to provide an irrigation schedule for this site, taking into consideration, wind, soil type, temperature and plant water use. Contractor shall then program the controller to produce the scheduled water rates for each day, week, and month. Contractor shall then observe the condition of the plants and adjust the schedule as needed to assure that the plants are not over or under irrigated. LANDSCAPE ARCHITECTS, INC. 74020 ALESSANDRO, SUITE E PALM DESERT, CA 92260 (760) 568-3624 FAX (760) 773-5615 E-MAIL: RGA•RGA-PD.COM W 0 W U Z O F_ U W CL Z 0 Z a TF A // E PrA TF W H W W 0 fr tL o: W Z or O Lei, W W Cc Z O oc 0 O O Z Cr. L a U E W 0 SPECIFICATIONS SHEET ❑ BOOK JOB CAPTAIN: RP DRAWN: TM CHECKED: PROJ. NO: R 0812 DATE: 5/5/10 SCALE: NYS REVISIONS: 0 0 SHEET NO: ljw L39109