HomeMy WebLinkAboutRevision (7) HOMEOWNER: CHRIS BERG " , �, M`� _ - ��+ �� - 1 GENERAL NOTES: PH: 4o8.510.9153 1Y ii}- 4' , p 1. THIS SYSTEM COMPLIES WITH THE 2022 CRC, 2022 CBC, 2022 CFC,AND THE 2022 Ll i� oADDRESS: 74320 ASTER DRIVE �' + 2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY PALM DESERT, CA 92260 _ - vo- lu HAS BEEN NOTIFIED. ?- - "�" 4 3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. PHOTOVOLTAIC SOLAR PROJECT INFORMATION: _ GI ea 4• THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 4o LBS. �� BERG • �� ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE SYSTEM SIZE: 12.40o kW(DC), 10.000 kW AC 1 • .�- 4, r � _ 5• Q ( ) RESIDENCE . UL 1741 COMPLIANT. 6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS MODULES: (31) SILFAB PRIME SIL-400 HC+ PEAK POWER - 400 W _ a FROM THE MAIN BREAKER. ' ^'� }'� �+ 7. CONDUCTORS ARE 9o°C RATED COPPER WIRE. MAX OPERATING CURRENT= 11.10 A " a IN g. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT MAX OPERATING VOLTAGE = 36.05 V °- _ r _ RESISTANT. OPEN CIRCUIT VOLTAGE = 43.02 V 9 IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING,THEY WILL BE CONTAINED SHORT CIRCUIT CURRENT= A 11. 8 ` - �� �`� 5 Ag; � �, ` •� l IN A METAL RACEWAY. MAX SERIES FUSE RATING = 20 A �� `� _ ' 10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE TEMP. COEFF. OF Voc =-0.28%/°C PROTECTED IN CONDUIT. DIMENSIONS = 75.3"X 40.8"X 1.4" r•. �'���• • 11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED WEIGHT= 47.4 LBS M 11F•♦ �•"41 i."� v�► F� : '` - FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES Ei AND RAILS AND SECURED IN PLACE. MODULE ADD-ON: (31)SOLAREDGE S440 ,a - • __9v_ « ^, 12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING DC POWER OPTIMIZERS VICINITY MAP CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. MAX DC INPUT VOLTAGE = 60 V 13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED OPERATING VOLTAGE RANGE= 8 V-6o V NTS FOR USE IN WET LOCATIONS. MAX DC INPUT CURRENT= 14.5 A SHEET INDEX: 14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN MAX DC OUTPUT CURRENT= 15 A SHEET 1 PROJECT INFO,VICINITY MAP, NOTES, SCOPE OF WORK ACCORDANCE WITH CEC 110.26. DC OUTPUT VOLTAGE=380 V SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL 15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR MAX POWER PER STRING SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL BUILDING ROOF VENTS. (CONTROLLED BY INVERTER)= 5700 W SHEET 4 CALCULATIONS, SIGNS 16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE NEMA 6P ENCLOSURE ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS GROUNDING ELECTRODE SYSTEM,A GROUNDING ELECTRODE SYSTEM WILL BE " STRUCTURAL REPORT INSTALLED PER CEC 250.5o.THE ELECTRICAL SERVICE WILL BE BONDED TO THE DIMENSIONS 5.1��X 6.11� X 1.z WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. WEIGHT= 1.6 LB 17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA ARRAY: INSTALLED WEIGHT= 2.8 PSF REGULATIONS. ROOF COVERAGE= 665 SF, INVERTER/DC DISCONNECT: (1) SOLAREDGE SE10000H-US ARRAYS COVER 25% OF TOTAL ROOF AREA MAX DC INPUT VOLTAGE =480 V ,CiFESSlo NOMINAL DC INPUT VOLTAGE=400 V ��e \N Nql MOUNTING HARDWARE: K2 CROSSRAIL 48X RAIL MAX DC INPUT CURRENT= 27.o A K2 EVERFLASH ECOMP KIT& DC DISCONNECT MAX INPUT CURRENT= 45.o A LU TILT-UP W/CHEM CURB ROOF ATTACHMENTS NUMBER OF DC INPUTS = 3 No. C58724 X,6" STAINLESS STEEL LAG BOLTS @ RATED AC POWER = l0000 W NOTE: * Exp.3-31-25 72" OC OR LESS WITH A MINIMUM OF AC VOLTAGE= 240 V Engineer of Record assumes that all structural components ��q C/Vi\, 2%" PENETRATION INTO ROOF RAFTERS MAX AC OUTPUT CURRENT= 42.o A of the existing building were permitted and met the p TFOF CA��F�� NEMA 4X ENCLOSURE g g EXISTING ROOF INFO: 1 STORY, SPANISH COMPOSITION UNDER ARRAYS TILE DIMENSIONS = 21.3" X 14.6" X 7.3" requirements of the Building Code at the time of September 6, 2023 2 X 4 RAFTERS @ 24" OC& WEIGHT= 39 LBS construction. Solar Contractor shall field verify that the roof www. Loyd W Martin .com TORCH DOWN ROOF framing is in its existing permitted condition and capable of Solar Structures Engineering 2 X 6 RAFTER @ 16" OC supporting required live loads. Framing specified on solar #2023-4735 Structural Only plans shall be assumed to be minimum size and spacing, NOTICE: actual framing may be different. ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. SCOPE OF WORK: PLANS PREPARED BY: UNDERLINE ENERGY INSTALL(31) SILFAB PRIME SIL-400HC+ SOLAR ELECTRIC MODULES AND JENNIFER KEMME Underline Energy CONCEPTS INC. (31) SOLAREDGE S44o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY _-_ PH: 909-748.1300 18540 PASADENA STREET TILE ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE,JUNCTION SHEET C 0 n C e p t S LAKE ELSINORE, CA 92530 BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL PH: 951.201.1900 (1) SOLAREDGE SE10000H-US INVERTER WITH INTEGRATED DC DISCONNECT, JESSE M. MALONE C10-1015714 1 OF 4 (1) FUSED AC DISCONNECT,AND CONNECT TO SCE INSTALLED GMA. DATE: 8/16/23 83984PV1 HOMEOWNER: CHRIS BERG PH: 4o8.510.9153 TOTAL ROOF AREA= 2625 SF ROOF ACCESS POINTS ARE AT THE EXISTING 1-STORY ROOF: TOTAL SOLAR AREA= 665 SF STRUCTURALLY STRONG PART OF ADDRESS: 74 PALM ASTER DRIVE 66 SF z62 SF= 0.2 * THE BUILDING AND DO NOT REQUIRE PALM DESERT, CA 9zz6o SPANISH TILE 5 / 5 5 Q (COMPOSITION SHINGLE ARRAYS COVER 25%OF TOTAL ROOF AREA LADDERING OVER OPENINGS. K2 CROSS RAIL 48X RAIL UNDER ARRAYS), MOUNTING SYSTEM WITH K2 FELT&'/z" SHEATHING — — — — — — EVERFLASH ECOMP KIT ROOF OVER RAFTERS PROPERTY ATTACHMENTS(USE%6"X 3'/z" LINE PROPERTY STAINLESS STEEL LAG BOLTS @a MODULES: LINE 72" OC OR LESS WITH A MINIMUM 75.3" X 40.8" 3" MIN. EMBEDMENT OF 2'/z" INTO ROOF 47.4 LBS EACH 8 MAX. 27'_91? RAFTERS),WATERPROOF ALL CONNECTION LOCATIONS PER MAN INSTRUCTIONS 18"-36" 3 ARRAY#4: (4) MODULES (E)200 AMP MAIN * TILT=15°,AZ =700 • SERVICE PANEL W/ \ I SCE INSTALLED GMA , „ EXISTING z X 4 31 � 5 -7 (N) FUSED AC DISCONNECT 30 \ ARRAY#3: (7) MODULES RAFTERS @ 24" OC I \ (N) INVERTER/ 29 \ /, TILT=19°,AZ =340° DC DISCONNECT z 28 z6 �5 �7 a ELEVATION DETAIL ARRAY#5: (3) MODULES 3 \ 2F_ n �4 3� Kz CROSSRAIL 48X RAIL MOUNTING NTS ° ° 1 -3 1�_6" 3 23 SYSTEM WITH K2 TILT-UP W/CHEM TILT= 14 ,AZ = z5o / ; ,� ° 21 zz / 14 CURB ROOF ATTACHMENTS(USE%6n 13'-5" 4 5, � 13 15 ° STAINLESS STEEL LAG BOLTS @a 64"X 3%" 5 MODULES: -4 fv 7 12\ 41 - OC OR LESS WITH�A MINIMUM 75.3" X 40.8" 6 8 \\ 11 16 ° PROPERTY EMBEDMENT OF 2/z INTO ROOF 47.4 LBS EACH ARRAY#1: (6) MODULES 9 j\ 10 17 1.5' FIRE CLEARANCE LINE RAFTERS),WATERPROOF ALL TILT= 10 ,AZ = 16o \ 18 CONNECTION PER MANUFACTURER'S ' " 3 � 19 •,, 5 -4 INSTRUCTIONS RRP� #A � VENT(TYP) 20 A 24" MAX N ARRAY#2: (11) MODULES TILT= 180,AZ = 2500 �oQ�tOFESS/pN9l WN EXISTING z X 6 o 2 c� RAFTERS @ 16" OC No. C58724 EXISTING 1-STORY ROOF: „_ Exp.3-31-25 TORCH DOWN, SCALE: 1/16 —1, 16' `�� C/V 1\- �P FELT&%" SHEATHING 8 16 32 48 9TFOF CAl\F OVER RAFTERS SITE/ROOF PLAN - - September 6, ASTER DRIVE 2023 ELEVATION DETAIL NOTE: www. Loyd W Martin .com NOTICE: NTS DIMENSIONS AND FEATURES SHOWN ARE CLOSE TO Solar Structures Engineering ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE SCALE BUT WERE TAKEN FROM A FIELD SURVEY AND #2023-4735 Structural Only APPROXIMATIONS MADE USING GOOGLE EARTH. WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. SCOPE OF WORK: PLANS PREPARED BY: UNDERLINE ENERGY INSTALL(31) SILFAB PRIME SIL-400HC+ SOLAR ELECTRIC MODULES AND JENNIFER KEMME Underline Energy CONCEPTS INC. (31) SOLAREDGE S44o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY PH: 909.748.1300 C 0 n C e p t S ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE,J LAKE0ELS1 ORE, CA 92530 BOX ,ASADENA STREET TILE CONDUIT, CONDUCTORS AND GROUND NG NSTALLUNCTION SHEET PH: 951.201.1900 (1)SOLAREDGE SE10000H-US INVERTER WITH INTEGRATED DC DISCONNECT, JESSE M. MALONE C10-1015714 2 OF 4 (1) FUSED AC DISCONNECT,AND CONNECT TO SCE INSTALLED GMA. DATE: 8/16/23 83984PV1 HOMEOWNER: CHRIS BERG PH: 4o8.510.9153 (3) 6 AWG THHN-z/THWNz & ELECTRICAL LINE DIAGRAM (1) 8 AWG GROUND ADDRESS: 7432o ASTER DRIVE IN Y4" EMT CONDUIT PALM DESERT, CA 9226o (6)10 AWG PV IN AIR (6)10 AWG THHN-2/THWN & 6o A, 240 VAC, 10 EXISTING SERVICE PANEL (1)8 AWG GROUND SOLAREDGE SE10000H-US FUSED AC DISCONNECT W/SCE INSTALLED GMA: (10) 600 VDC 240 VAC 10 LOCKABLE VISIBLE SOURCE CIRCUIT#1: SOLAREDGE S440 NEMA 3R, 600 VDC IN %4" EMT CONDUIT TRANSFORMERLESS INVERTER KNIFE-BLADE TYPE Zoo A BUS RATED, 240 VAC, 10 10 MODULES, 600 VDC OPTIMIZERS JUNCTION BOX @ MAIN SERVICE INFO: SILFAB PRIME 0 0 @ M 20o A, 120/240 VAC, SIL-400HC+ 0 @ 6oA @ 10, 3-WIRE O — — — — — — — CONDUIT MUST BE SUPPORTED A MINIMUM 0 METER#222013-539596 N 200A SILFAB PRIME OD O OF%$"ABOVETHE ROOF SURFACE. SIL-400HC+ O O - - - - - - - � F- - - - - - - - - - SOLAREDGE INTEGRATED - - - - - - (10) 600 VDC DC DISCONNECT& RAPID SOURCE CIRCUIT#2: SOLAREDGE S440 SHUTDOWN DEVICE (3)6 AWG THHN-2/THWN2 10 MODULES, 600 VDC OPTIMIZERS IN %4" LFNC CONDUIT SILFAB PRIME O O SIL-400HC+ O O SILFAB PRIME O O SIL-400HC+ O O L — — — _ — EXISTING BUILDING GROUNDING� - - — — — — — _— ELECTRODE SYSTEM (11)600 VDC SOURCE CIRCUIT#3: SOLAREDGE S440 11 MODULES, 600 VDC OPTIMIZERS SILFAB PRIME O O SIL-400HC+ O 0 SILFAB PRIME 0 0 SIL-400HC+ O O F I - - - - - - - - - - - - - - - - - - USE Kz INTEGRATED GROUNDING TO GROUND ALL MODULES, OPTIMIZERS, JUNCTION BOXES AND ANY OTHER METAL PARTS AND#6 AWG SOLID COPPER WHERE NECESSARY NOTICE: ANY CHANGES TO OR USES OF THESE DOCUMENTS/DRAWINGS WITHOUT THE WRITTEN CONSENT OF JENNIFER KEMME OR SCOTT HARRIS ARE STRICTLY PROHIBITED. SCOPE OF WORK: PLANS PREPARED BY: UNDERLINE ENERGY INSTALL(31)SILFAB PRIME SIL-400HC+ SOLAR ELECTRIC MODULES AND JENNIFER KEMME Underline Energy CONCEPTS INC. (31) SOLAREDGE S44o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY PH: 909.748.1300 C 0 n C e p t S 18540 LAKE EPASADENA STREET TILE LSI ORE, CA 92530 BOX , CONDUIT, CONDUCTORS AND GROUND F. INSTALL ASSOCIATED MOUNTING HARDWARE NG NSTALLUNCTION SHEET PH: 951.201.1900 (1) SOLAREDGE SE1000OH-US INVERTER WITH INTEGRATED DC DISCONNECT, JESSE M. MALONE C10-1015714 30174 (1) FUSED AC DISCONNECT,AND CONNECT TO SCE INSTALLED GMA. DATE: 8/16/23 83984PV1 HOMEOWNER: CHRIS BERG SYSTEM SIGNAGE PH: 408.510.9153 ALL SIGNAGE SHALL BE REFLECTIVE, UV RESISTANT TO BE INSTALLED ON THE FRONT OF THE MAIN SERVICE DISCONNECT: PLASTIC, RED IN COLOR WITH WHITE LETTERING,AND "SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN" SHALL BE ADDRESS: 74320 ASTER DRIVE ATTACHED WITH WEATHERPROOF ADHESIVE OR BLACK LETTERING ON YELLOW BACKGROUND.THE REMAINDER OF PALM DESERT, CA 92260 OTHER APPROVED METHOD. ALL LETTERS SHALL BE A THE SIGN SHALL BE BLACK LETTERING ON WHITE BACKGROUND. MINIMUM OF Y8" HEIGHT AND ALL CAPITALIZED. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN CAUTION : ALL CONDUIT,JUNCTION BOXES AND OTHER ENCLOSURES TURN RAPID SHUTDOWN SHALL BE MARKED AT 10 MAX INTERVALS AND AT ALL SWITCH TO THE BENDS,TERMINATIONS, SPLICES OR CONNECTIONS WITH POWER TO THIS BUILDING IS ALSO "WARNING: PHOTOVOLTAIC POWER SOURCE". SHUOTFDOWNIPVOYSOM SOLARELECTRIC PV PANELS SUPPLIED FROM THE FOLLOWING SOURCES TO BE INSTALLED AT ALL SERVICEABLE PANELS AND REDUCE WITH DISCONNECTS AS SHOWN. OR BOXES AND AT ALL DISCONNECTS: SHOCK THE ARRAY WARNING ELECTRIC SHOCK HAZARD SYSTEM CALCULATIONS: N DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE MODULE POWER=400 W MAX SYSTEM VOLTAGE(Voc)CONTROLLED BY AND LOAD SIDES MAY BE ENERGIZED NUMBER OF MODULES IN LONGEST STRING =11 INVERTER=48o V IN THE OPEN POSITION (11)400 W=4400 W WARNING OPTIMIZER MAX POWER PER STRING =6000 W SHORT-CIRCUIT CURRENT(Isc)CONTROLLED BY ELECTRIC SHOCK HAZARD 4400 W< 6000 W, OK OPTIMIZER= 15.00 A THE DC CONDUCTORS OF THIS INVERTER MAX OUTPUT CURRENT=42.00 A PHOTOVOLTAIC SYSTEM ARE OPERATING CURRENT= SOLAR ARRAY UNGROUNDED MAY BE ENERGIZED POWER RATING/OPERATING VOLTAGE= 42.00 A(1.25)= 52.50 A[Ic], USE 6o A FUSE (ON ROOF) 4400 W/400 V=11.0o A TO BE INSTALLED ON THE OPTIMIZER TO INVERTER TARGET FRONT OF THE DC DISCONNECT: VOLTAGE/OPERATING VOLTAGE=400 V PV SOLAR DC DISCONNECT MAXIMUM VOLTAGE=480.00 V WIRE CALCULATIONS: MAXIMUM CIRCUIT CURRENT=45.00 A FROM OPTIMIZERS TO INVERTER/DC DISCONNECT: MAXIMUM RATED OUTPUT CURRENT OF THE AMBIENT TEMPERATURE=47°C DC-TO-DC CONVERTER=15.0o A TEMPERATURE ADDER FOR CONDUIT OFFSET FROM ROOF BY MIN Y8"= o°C ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR go°C INSULATED CONDUCTOR AT INVERTER & TO BE INSTALLED ON THE 47°C+ o°C- 69°C- o.82 DC DISCONNECT FRONT OF THE AC DISCONNECT: Isc=15.00 A SERVICE POINT & RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 15.00 A/o.82 =18.29 A UTILITY METERING PV SYSTEM DISCONNECT NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT= 6 FOR UTILITY OPERATION RATED AC OUTPUT CURRENT= 52.25 A ADJUSTMENT FACTOR PER TABLE 310.15(B)(3)(a) FOR CONDUIT FILL(4-6 CONDUCTORS IN ADDRESS: 74320 ASTER DRIVE, PALM DESERT, CA 92260 NOMINAL OPERATING AC VOLTAGE= 240 V CONDUIT)= o.8o 18.29 A/o.8o =22.31 A TO BE INSTALLED ON THE OUTSIDE COVER TO BE INSTALLED AT THE BACKFED SELECT WIRE SIZE WITH AMPACITY GREATER THAN 22.31 A, USE 10 AWG THWN-2 COPPER OF THE MAIN SERVICE DISCONNECT: BREAKER SERVING THE PV SOLAR SYSTEM: WIRE WITH AN AMPACITY OF 4o A WARNING SELECT CONDUIT FOR(4)10 AWG THHN-2/THWN &(1)8 AWG GROUND=Y4" EMT CONDUIT POWER SOURCE OUTPUT CONNECTION - DO NOT RELOCATE THIS OVERCURRENT DEVICE FROM THE INVERTER TO THE MAIN SERVICE PANEL: ADJUSTMENT FACTOR PER TABLE 310.15(B)(2)(a) FOR go°C INSULATED CONDUCTOR AT 47°C= 0.87 NOTICE: Ic= 52.25 A ANY CHANGES TO OR USES OF THESE 52.25 A/o.91 = 6o.o1 A DOCUMENTS/DRAWINGS WITHOUT THE SELECT WIRE SIZE WITH AMPACITY GREATER THAN 6o.o1 A, USE 6 AWG THHN-2/THWN WRITTEN CONSENT OF JENNIFER KEMME OR COPPER WIRE WITH AN AMPACITY OF 75 A SCOTT HARRIS ARE STRICTLY PROHIBITED. SELECT CONDUIT FOR(3) 6 AWG THHN-2/THWN &(1) 8 AWG GROUND =Y4" EMT CONDUIT SCOPE OF WORK: PLANS PREPARED BY: UNDERLINE ENERGY INSTALL(31) SILFAB PRIME SIL-400HC+ SOLAR ELECTRIC MODULES AND JENNIFER KEMME Underline Energy CONCEPTS INC. (31) SOLAREDGE S44o DC POWER OPTIMIZERS ON THE EXISTING 1ST STORY ___ PH: 909.748.1300 18540 PASADENA STREET TILE ROOF. INSTALL ASSOCIATED MOUNTING HARDWARE,JUNCTION SHEET C o n C e p t S LAKE ELSINORE, CA 92530 BOXES, CONDUIT, CONDUCTORS AND GROUNDING. INSTALL PH: 951.201.1900 (1)SOLAREDGE SE1000OH-US INVERTER WITH INTEGRATED DC DISCONNECT, JESSE M. MALONE C10 -1015714 4 OF 4 (1) FUSED AC DISCONNECT, AND CONNECT TO SCE INSTALLED GMA. DATE: 8/16/23 83984PV1 ELECTRICAL SPECIFICATIONS 400 Test Conditions STC NOCT Module Power(Pmax) Wp 400 298 • Maximum power voltage(Vpmax) V 36.05 33.50 • • Maximum power current(Ipmax) A 11.10 8.90 • • Open circuit voltage(Voc) V 43.02 40.35 SILFAB PRIME 5 I L FA B • Short circuit current(Isc) A 11.58 9.34 SOLAR° Module efficiency % 20.2% 18.8% Maximum system voltage(VDC) V 1000 SIL-400 HC+ Series fuse rating A 20 Power To[era nce W p 0 to+10 Measurement conditions:STC 1000 W/m'•AM 1.5•Temperature 25°C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty<_3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10W. MECHANICAL PROPERTIES/COMPONENTS Module weight 21.3kg±0.2kg 471bs±0.41bs Dimensions(H x L x D) 1914 mm x 1036 mm x 35 mm 75.3inx40.8inx1.37in Maximum surface load(wind/snow)* 5400 Pa rear load/5400 Pa front load 112.8 Ib/ft'rear load/112.8[b/ft2 front load Hail impact resistance o 25 mm at 83 km/h o 1 in at 51.6 mph Cells 132 Halfcells-Si mono PERC 132 Halfcells-Si mono PERC 9 busbar-83 x 166 mm 9 busbar-3.26 x 6.53 in Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, DSM antireflective coating DSM antireflective coating Cables and connectors(referto installation manual) 1350 mm,o 5.7 mm,MC4 from Staubli 53 in,0 0.22 in(12AWG),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, Fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated [TEMPERATURE RATINGS WARRANTIES Temperature Coefficientlsc +0.064%/°C Mod ule prod uct workmanship warranty 25 years** Temperature Coefficient Voc -0.28%/°C Linear power performance guarantee 30years Temperature Coefficient Pmax -0.36%/°C >_97.1%end 1st yr NOCT(±2°C) 45°C >_91.6%end 12th yr >_85.1%end 25th yr Operating temperature -40/+85°C >_82.6%end 30thyr CERTIFICATIONS SHIPPING SPEC UL61215-1:2017Ed.1,UL61215-2:2017Ed.1,UL61730-1:2017Ed.1,UL61730-2:2017 Modules Per Pallet: 26 or 26(California) Ed.1,CSA C22.2#61730-1:2019 Ed.2,CSA C22.2#61730-2:2019 Ed.2,IEC 61215-1:2016 Product Ed.1,IEC 61215-2:2016 Ed.1,IEC 61730-1:2016 Ed.2,IEC 61730-2:2016 Ed.2,IEC 61701:2020(Salt Mist Corrosion),IEC 62716:2013(Ammonia Corrosion),UL Fire Rating: Pallets Per Truck 32 or 31(California) Type 2,CEC Listing*** Factory IS09001:2015 Modules Per Truck 832 or 806(California) * AWarning.Read the Safetyand Installation Manua[for mounting specifications and before handling,installingand operating modules. ** 12year extendableto25 yearssubjectto registration and conditions outlined under"Warranty"atsilfabsolar.com. PAN files generated from 3rd party performance data are available for down[oad at:silfabsolar.com/downloads. *** CEC listing in progress.January 2023,expected completion. _ 75.3"[1914mm] v E 12.1"[307mm] 51.2[1300mm] 12.1"[307mm] RELIABLE ENERGY. ounting Hole(x4) � SILFAB SOLAR INC. Cornwall Ave DIRECT FROM THE SOURCE . 800nghamWA9 0.5" Bellingham WA 98225 USA [12mm] T+1360.569.4733 Designed to outperform. info@silfabsolar.`om 3 CD SILFABSOLAR.COM a, Dependable, durable, high-performance E E 1770 Port Drive solar panels engineered for North m 1.4" 35mm E M Burlington WA98233USA n �' _o T+1360.569.4733 American homeowners. A o X of Go 240 Courtneypark Drive East w o Mississauga ON L5T 2Y3 Canada S I L F A B S O L A R.C O M 3 N r+1905.255.2501 3 0.06" 53.15" F+1905.696.0267 �i [1.5mm] �--T able Length t9 CableLerlgth N- o Sitfab-SIL-400-HC+-20221228 0 0 No reproduction of any kind is allowed without rainage Hole(x8) O LC] permission.Data and information is subject to // ET T modifications without notice.©Silfab Solar Inc., C E I E� o Sofa Solarifab olar®isa registered trademark of Fraunhofer C H U B B Silfab solar lnc. Intertek Intertek -0 ISE *Chubb provides error and omission insurance to Silfab Solar Inc. 2.4"[60mm] 8"[200mm] Power Optimizer Power Optimizer For North America O 5440 / S500B / S650B For North America ... S500B INPUT S440 / S 5 0 0 B / S 6 5 0 B Rated Input DC Powerl'I 440 1 500 1 650 W Absolute Maximum Input Voltage(Voc) 60 125 85 Vdc MPPT Operating Range 8—60 12.5—105 12.5—85 Vdc Maximum Short Circuit Current(Isc)of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % 25 Weighted Efficiency 98.6 % Overvoltage Category II YEAR OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) WARRANTY O Maximum Output Current 15 Adc Maximum Output Voltage 1 60 1 80 1 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR INVERTER OFF) Safety output Voltage per Power Optimizer 1±0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014,2017&2020 EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 Material UL94 V-0,UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS N Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H) 129 x 1S5 x 30/ 129 x 165 x 45/5.07 x 6.49 x 1.77 mm/in 5.07 x 6.10 x 1.18 Weight 720/1.6 1 790/1.74 gr/lb Input Connector MC412' Input Wire Length 0-1/032 m/ft Output ut Connector MC4 Output Wire Length (+)2.3,(-)0.10/(+)7.54,(-)0.32 m/ft Operating Temperature Range(3) -40 to+85 C Protection Rating IP68/NEMA6P Relative Humidity 0—100 % (1)Rated power of the module at STC will not exceed the power optimizer Rated Input DC Power.Modules with up to+5%power tolerance are allowed. (2)For other connector types please contact SolarEdge. (3)Power de-rating is applied for ambient temperatures above+85°C/+185°F for S440,and for ambient temperatures above+75°C/167°F for S5008.Refer to the Power PVpower optimization at the module level Optimizers Temoerature De-Ratinct Technical Nate for more details. PV System Design Using a SolarEdge :0 Specifically designed to work with SolarEdge Faster installations with simplified cable Inverter Single Phase 208V ' Grid Minimum String Length S440 8 10 18 _ residential inverters management and easy assembly using a single (Power Optimizers) S500B,S650B 6 1 8 14 bolt Maximum String Length(Power Optimizers) 25 5010) Detects abnormal PV connector behavior, Maximum Nominal Power per String 5700(6000 with SE7600-US-SE11400-U) 6000 12750 W preventing potential safety issues Flexible system design for maximum space Maximum Allowed Connected Power per String() One string7200 (Permitted only when the difference in connected power Refer to footnote 5 Two strip s or more 7800 15000 W utilization between Strings is 1,OODW Or less) g Module-level voltage shutdown for installer Parallel Strings of Different Lengths or Orientations Yes and firefighter safety Compatible with bifacial PV modules (4)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements,safety voltage will be above the 30V requirement. (5)If the inverters rated AC power s maximum nominal power per string,then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to the S ngle String Design Guidelines Application Note for more details. Superior efficiency (99.5%) Meets NEC requirements for arc fault (6)It is not allowed to mix S-series and P-series Power Optimizers in new installations. protection (AFCI) and Photovoltaic Rapid S440 "' 0' (Bent Bracket) Mitigates all types of module mismatch loss, Shutdown System (PVRSS) from manufacturing tolerance to partial shading 5 t17 W ._ _ B2 _ s o I a re d g e.c o m solar=ee So arEdge Technologies,Ltd.All rights reserved.SOIAREDGE the SolarEdge logo,OPTIMIZED BY SOIAREDGE are trademarks or registered trademarks of SolarEdge Techwlogies,Inc All other trademarks mentioned herein are trademarks of their respective owners.Date:March 1,2023 DS-000018-NA.Subject to change without notice, cC )us Ro H s Intertek _ Single Phase Inverter with HD-Wave TechnOlOgy for North America Si n l PhaseInverter z eSE3000H-US SE3800H-US SE5000H-US SE6000H-US < SE760OH-US / SE1000OH-US / SE1140OH-US with H D-Wave Technology for North America APPLICABLE TO INVERTERS SEXXXXH-XXXXXBXX4 WITH PART NUMBER SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US / OUTPUT S E7600 H-U S / S E 10000 H-U S / S E 11400 H-U S Rated AC Power Output 3000 3800 @ 2V 5000 6000 @ 2V 7600 10000 100 @ 2V VA 3300 @ 20808V 5000 @ 20808V 1000000 @ 20808V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V 12-25 AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac ;a (211-240-264) YEAR O AC Output Voltage Min. Nom. Max. (183-208 229) '� '� ✓ Vac AC Frequency(Nominal) 59.3-60-60.50) Hz ® 0 Maximum Continuous Output Current @240V 125 16 21 25 32 42 47.5 A Maximum Continuous Output - 16 - 24 - - 48.5 Current @208V 0 0 Power Factor 1,Adjustable-0.85 to 0.85 0 GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT • solar,== .,r i^w ® 0 solar•..> _HD__ Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W ® Maximum DC Power @208V 5100 7750 155 Ri_ { X Transformer-less,Ungrounded Yes • © Maximum Input Voltage 480 Vdc a 0 Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(1) 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2) - 9 13.5 - 27 Adc Max.Input Short Circuit Current 45 Adc a n g p Reverse-Polarity Protection Yes - _ Ground-Fault Isolation Detection 600ko Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V Nighttime Power Consumption <2.5 W Optimized installation with HD-Wave technology (1)For other regional settings please contact SolarEdgesupport R)A higher current source may be used;the inverter will limit its input current to the values stated Specifically designed to work with power optimizers UL1741 SA certified, for CPUC Rule 21 grid compliance Record-breaking 99% weighted efficiency Small, lightweight, and easy to install both outdoors or indoors Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Built-in module-level monitoring Fixed voltage inverter for longer strings Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade Integrated arc fault protection and rapid metering (0.5% accuracy, ANSI C12.20) shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 solaredge.com solar / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Metering,ANSI C12.20 Optionali3l Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown-NEC 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG Range DC Input Conduit Size/#of Strings/ 1''Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /4S0 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/ (HxWxD) mm Weight with Safety Switch 22110 25.1/11.4 26.2/11.9 38A/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60(4) T/°C Protection Rating NEMA 4X(Inverter with Safety Switch) "I Inverter with Revenue Grade Meter P/N:SExxxxH-US00013NC4;Inverter with Revenue Grade Production and Consumption Meter P/N:SExxxxH-US000BNI4.For consumption metering,current transformers should be ordered separately:SEACT0750-20ONA-20 or SEACT0750-400NA-20.20 units per box 14�Full power up to at least 50°C/122°F;for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel,homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD-wave technology and built-in RGM and Service Panel consumption monitoring Grid O_T rTTT Cr L1 N L2 Shielded CATSe cable - ---- --------- - -- ------------ ------ ---' L1- ---- N L2 AC Conduit ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Rill other trademarks mentioned herein are trademarks oft heir respective owners.Date:01/2020N01/ENG NAM.Subject to change without notice. 1 1 1 1 1 1 \ \ \ I _ - . . . 1 p \ Com onents a�orrnerly Everest Solar Sy SA It 1 1 _ - 1 1 -I � - - - 11\11\11\11\11\11\11\11\11\11\ll\1 CrossRail yLl-X CrossRail y8-X CrossRail L18-XL MEN1\\\\\\\\11\►1\\\\\\\\1 -- ► 1\11\\\\\\\\11\II\\\\\\\\1,\,1„ ,,,,,,,,",,,,"`1 Part Number Description Part Number Description Pert Number Description 4000019 CrossRail44-X 156;Mill 4000662 CrosBRail4B-X,166;Mill 4000695 CrossR91148-XL 166,MITI ►�► 1\►1\►1\►1\►1\►„1 1,,,,,"„` 4000020 CrossRail44-K 166,Dark 4000663 CrossRall48-K 266;Bark 4000705 CrossRall48-XL 166;Berk 4000021 CrossRail 44-K 180;Mill 4000675 CrossRail 48-X,180,Mill I ,i 11 ►�\► 1\11'►1'11",,,1„ ,\„\„\ 4000022 CrossRail 44-X,180,Dark 4000665 CrossRail 48-X,180;Dark _T7 Z i iTEA 42 VIONEENNER ter ► t�t���► �\ �w, CrossRail 80 CrossRail Mid Clamp CrossRail End Clamp 70 \\\\\\\\11\11", Part Number Description Part Number Description Part Number Description 4000508 1 CrossRail 80,168;MIII 4000601-H CR MC Silver,30-47mm,13mm Hex 4000429 CR EC Silver 30-SOmm,SR 30-45mm 1 1`?� ��,�\► 1\►►►►1\\\\\\\\11\ 4000602-H CR MC Doric,30-47mm,13mm Hex L1000430 CR EC Dark 30-50mrr SR 30-45mm 4000688-H SR MC Silver,30-50mm,13mm Hex 4000003 SR EC Silver 46-50mm _ 4000689-H SR MC Silver,30-50mm,13mm Hex 4000004 SR EC Bark 46-50mm CrossRail System »'004i Yeti Clamp Aluminum End Clamp CrossRail Rail Connector Part Number Description Part Number Description Part Number Description 40000SO-H I Yeti Hidden EC for CR,Mill,13mm Hex 4005344 CrossRail EC Silver,AL 32-33mm 4000051 Rail Connector CR 44-X,Set Mill 4005169 CrossRail EC Silver,AL 34-36mm 4000052 Rail Connector CR 44-X,Set Dark ► High quality, German-engineered system for residential and commercial installations 4005290 CrossRail EC Silver.AL 37-38mm 4000385 RailConnCR48-X,48-XLStructSetMill 4005170 CrossRail EC Silver,AL 39-41mm 4000386 RailConn CR48-X,4841.Struct Set Dark ► U rail sizes available to suit all structural conditions 4005291 CrossRall EC Silver,AL 42-44mm 4001196 Rail Connecctor UL 2703 Set CR80,MIII 4005171 CrossRail EC Silver,AL 45-47mm ► Universal components for all rail types 4005292 CrossRail EC Silver,AL48mm 40OS172 CrossRail EC Silver,AL 49-50mm ► Use 2 innovative components to turn this system into Shared Rail or Tilt Up F ► MK3 technology provides highest rail engagement • �1 Roof attachments for all roof types • 11 ► 100%code compliant,structural validation for all solar states L-Foot 6T-Foot Tile Hooks Standing Seam PowerClamps Part Number Description Part Number Description Part Number Description ► Fast installation with minimal component count result in low total installed cost 4000630 L-Foot Slotted Set Mill 4000034 Flat Tile Hook 4000016 Standing Seam PowerClemp,Mini 4000631 L-Foot Slotted Set Bark 4001294 Tile Hook 3S 4000017 Standing Seam PowerClemp,Standard O� 4000080 T-Foot X,Set Mill 4000521 SingleHook 2 AV 190: system V16i,, Ir 41V EverFlash Flashings Everest Ground Lug CR Microinverter 6 Opt Mounting Kit Part Number Description Parc Number Description �pa,Number Description 1 4000366 EverFlash eComp Kit Black 4000006-H Everest Ground Lug Set 13mm Hex 06"-H CR Microinverter 6,Opt Mounting Kit 13mm 4000367 EverFlash eComp Kit Dark 4000679 EverFlash eComp Kit,Mill LF,Dark Flesh Wire Management End Caps CR y8-X/148-XL Sleeve Part Number Description Part Number Description PartNumbar Description 4000069 TC Wire Management Clip 4000087 CR 44-X End Cap 14000583 CR 48-X/48-XLT Black Sleeve 4000382 Sunronner Cable Clip 4000431 CR 48-X/48-XL Flat End Cap 4005394 Omega Wire Mangement Clip 4000433 CR 48-X/48-XL End Cap 4001221 CR BO End Cep AV 190� ZIA We support PV systems We support PV systems PP Y Formerly Everest Solar Systems Formerly Everest Solar Systems MA EverFlash eComp Kit EverFlash eComp Kit 1141- Item .. Description 1 5/16" Lag Screw w/EPDM washer LI000366 EverFlash eComp Kit, Black y000367 EverFlash eComp Kit,Silver 2 T-Bolt E Hex Nut 4000679 EverFlash eComp Kit, Mill LF, Dark Flash Part Number Description 3 L-Foot 4000366 EverFlash eComp Kit.Dark 4000367 EverFlash eComp Kit Silver 4 eComp Flashing 4000679 EverFlash eComp Kit Mill LF,Dark Flash ► High quality, patented design to ensure watertight seal Technical Data ► Included as part of a UL 2703 Listed system EverFlash eComp Kit ► Easy installation,can be retrofitted without removing shingles Roof type Composition shingle ► Meets or exceeds all known building codes Material Aluminum and stainless steel for high corrosion resistance ► Aluminum base with stainless steel hardware for high corrosion resistance Finish Mill or dark anodized ► Compatible with all CrossRail systems Roof connection 5/16"lag screw Code compliance UL 2703, IAMPO Certified Compatibility CrossRail yy-X,98-X,98-XL,80 We support PV systems We support PV systems Formerly Everest Solar Systems 04 Formerly Everest Solar Systems Aft Units: [mm] in LFT -j9u [44] 48 1.732 1.890 [39] [39] [39] 1.535 1.535 1.535 Technical Data CrossRail Tilt Up System CrossRail Tilt Up System Roof Type Composition shingle,tile,standing seam Material High corrosion resistance stainless steel and high grade aluminum Flexibility Modular construction,suitable for any system size,height adjustable NumberItem Description Part Num.- PV Modules For all common module types 1 CrossRail yy-X(shown]all CR profiles applicable y000019(166"mill),y000020 (166"dark),4000021 [180"mill),y000022[180"dark] Module Orientation Portrait and landscape 2 CrossRail Mid Clamp y000601-H[mill],y000602-H (dark] Roof Connection Drill connection into rafter 3 CrossRail[Standard] End Clamp y000y29[mill],U0001430[dark] Structural Validity IBC compliant,stamped engineering letters available for all solar states y Yeti Hidden End Clamp for CR 9000050-H Warranty 25 years 5 Climber Set w/Hole,13mm Hex 1400060142-H [4B-X,48-XL]4006043[yq-X] 6 CrossRail Tilt Connector Set 41000505 7 L-Foot Slotted Set y000630(mill),y000631[dark] 8 CrossRail yy-X Rail Connector(shown) 14000051(mill],y000052(dark) CR 148-X,98-XL Rail Connector available 9 Everest Ground Lug y000006-H 10 CrossRail yy-X End Cap(shown] 14000067 CrossRail 98-X,98-XL and 80 available We support PV systems We support PV systems Formerly Everest Solar Systems 04 Formerly Everest Solar Systems 0% 0 it 9M t Mechanical Properties Mechanical Properties Material 6000 Series Aluminum Material 6000 Series Aluminum Ultimate Tensile Strength 37.7 ksi(260 MPa] Ultimate Tensile Strength 37.7 ksi(260 MPa) Yield Strength 34.8 ksi(240 MPa) Yield Strength 34.8 ksi(240 MPa] Weight OAR Ibs/ft[0.699 kg/m] Weight 0.56 Ibs/ft(0.833 kg/m] Finish Mill or Dark Anodized Finish Mill or Dark Anodized Sectional Properties Sectional Properties Sx O.149D in3(0.3785 cm3) Sx 0.1980 in3(3.245 cm3) Sy 0.1450 in3[0.3683 cm3] Sy 0.1510 in3[2.474 cm3] A[X-Section] 0.4050 in2(1.0287 cm2 A[X-Section] 0.4650 in'[2.999 cmz] Units: [mm] in Units: [mm] in r [39] 14216.40 [39] [4216.40] _ 1.54 r 166 �] 1.54 166 i 441 [48] 1.73 1.89 1 Notes: Notes: Structural values and span charts determined in accordance with Aluminum Design Manual and ASIDE 7-16 UL2703 Listed System for Fire and Bonding Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-16 � 0 UL2703 Listed System for Fire and Bonding We support PV systems C'rossRail Tilt Up Installation 13imension5 Formerly Everest Solar Systems The CrossRail Tilt Up System is a fully customizable solution. Figure 2 and Table 1 below provide is) recommended installation dimensions based upon a standard 60-cell and 72-cell PV module with 1/6-point clamping locations.Always ensure that the dimensions are suitable for the project site. Mechanical Properties e, 90, A CrossRail 148-XL Material 6000 Series Aluminum Ultimate Tensile Strength 37.7 ksi(260 MPa) Figure 2:CrossRail Tilt Up Leg Dimensions Yield Strength 34.8 ksi(240 MPa] Desired Tilt Angle Weight 0.76 Ibs/ft(1.13 kg/m) Dimcnsion De5cription 15 Degrees 10 Degrees 7 Dogrees Portrait Landscape Portrait Landscape Portrait Landscape Finish Mill or Dark Anodized 60672 .0 60672 60 A Front Leg 54.5 62 39 54.5 62 39 S4.S 62 39 Sectional Properties B Rear Leg 15 16.5 10 95 11 6.75 65 7.5 4.75 CrossRail L48-XL C L-Foot Spacing 54 64 40 53 63 39.5 52.5 625 39 Sx 0.2420 in'(3.966 cm3) o Rail Offset 5 5 5 5 5 5 5 5 5 Sy 0.2140 in'(3.507 cm3) E Module Length 65 79 39 5 65 79 39.5 65 79 39.5 A(X-Section) 0.6520 inz(4.206 cmz) F Rear Module 22 25 10 17 18 7 14 15 5 Height G Front Module 3 1/3 3 1/3 3 1/3 3 7/8 3 7/8 3 7/8 4 1/8 4 1/8 4 1/8 Units: [mm] in Height _ 39 _ _ 4216.40 Table 1:CrossRail Tilt Up installation dimensions 1.54 166 Note:All dimensions are in inches *Note:/degree tilted systems in landscape require specific configurations. Important Notes: 48 1.Rail Offset not to exceed 8 inches. 89 2. Rear module height not to exceed 30 inches, Note that dimension provided in Table 1 does not roof attachment 1. height. r' 3. Front module height dimension does not include roof attachment height. 4.Refer to CrossRail Tilt Up Engineering Letter(s)for reaction loads at L-Feet. 5. Always refer to chosen PV module manufacturer's installation instructions for approved clamping locations. Dimensions in Table 1 assume a standard 60-cell or 72-cell module with clamping locations at the 1/6-points Notes: on the module's long edge. 6. Installer is responsible for cutting rail to lengths specified"A"and"B"in Table 1. Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-16 7.Dimensions provided in Table 1 are suggested values. Installer shall verify dimensions are appropriate for the 0 UL2703 Listed System for Fire and Bonding individual site conditions,selected PV module and roof surface. 8.Adjust based on your installation needs. 6