HomeMy WebLinkAbout_SOLR23-0971_Kacie Goettsch Residence_15923 PlanSetSHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-0 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV 1 2 HOUSE PHOTO VICINITY MAP SCALE: NTSE-0 E-0 SCALE: NTS PROJECT SITE COVER PAGE PROJECT SITE SCOPE OF WORK TO INSTALL A TESLA BATTERY PACK SYSTEM WITH PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 41743 AVENTINE CT. PALM DESERT CA 92260 INSTALL ADVANCED ENERGY SYSTEM WITH PV SYSTEM: (2) TESLA POWERWALL 2 AC BATTERIES SYSTEM (10KW, 27KWH) (1) TESLA BACKUP GATEWAY 2 WITH INTERNAL PANELBOARD (26) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (1) TESLA SOLAR 7.6KW 1538000-XX-Y INVERTER (9) TESLA MCI (MID CIRCUIT INTERRUPTER) (1) BACKUP LOAD PANEL (1) REMOTE DISABLE SWITCH APPLICABLE CODES & STANDARDS 2022 CALIFORNIA ELECTRICAL CODE. 2022 CALIFORNIA RESIDENTIAL CODE. 2022 CALIFORNIA FIRE CODE. 2022 CALIFORNIA BUILDING CODE. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE. 2022 CALIFORNIA ENERGY CODE. 2022 CALIFORNIA PLUMBING CODE. 2022 CALIFORNIA MECHANICAL CODE.SYSTEM RATING 10.40 KWDC 7.6 KWAC SHEET INDEX E-0 COVER PAGE E-1 PLOT PLAN WITH ROOF PLAN E-2 ROOF PLAN & MODULES E-2A DESIGN SUMMARY E-2B STRING LAYOUT E-2C ELEVATION PLAN E-3 ATTACHMENT DETAIL E-4 ELECTRICAL LINE DIAGRAM & CALCS. E-4A WIRING CALCULATION E-5 WARNING LABEL & PLACARDS E-6 SAFETY PLAN E-7+EQUIPMENT SPECIFICATIONS E-19+POWERWALL ANCHORAGE DETAIL GENERAL NOTES: 1. THESE NOTES SET MINIMUM STANDARDS FOR CONSTRUCTION. THE DRAWINGS GOVERN OVER THESE NOTES TO THE EXTENT SHOWN. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING: LOCAL BUILDING CODE, LOCAL ELECTRICAL CODE, ANY PORTION OF THE WORK AND THOSE CODES AND STANDARDS LISTED IN THESE DRAWINGS AND IN THE SUBCONTRACTOR AGREEMENT. REFER TO REFERENCE DOCUMENTS LIST. 2. COORDINATE THESE DRAWINGS WITH SPECIFICATIONS AND MANUFACTURER'S INSTALLATION AND OPERATION MANUALS AND NOTIFY CONTRACTOR OF ANY DISCREPANCIES PRIOR TO BEGINNING WORK. 3. PRIOR TO THE COMMENCEMENT OF ANY WORK, EACH TRADE SHALL VERIFY EXISTING CONDITIONS AND NOTIFY CONTRACTOR OF ANY DISCREPANCIES TO THAT WHICH IS SHOWN IN THESE DRAWINGS, INCLUDING BUT NOT LIMITED TO DIMENSIONS OF THE WORK AREA, STRUCTURE, EXISTING ELECTRICAL SERVICE, CONDUIT PATHS, OBSTRUCTIONS, ACCESSIBILITY ISSUES, AND WORKING CLEARANCES. UNLESS INDICATED AS EXISTING (E), ALL PROPOSED MATERIALS AND EQUIPMENT ARE NEW. 4. MAINTAIN CONTINUITY OF ALL EXISTING CIRCUITS OR PORTIONS THEREOF AFFECTED BY NEW WORK. 5. ALL ITEMS TO BE REMOVED AND RELOCATED OR REPLACED SHALL BE HANDLED WITH PROPER CARE AND STORED IN A SAFE PLACE TO PREVENT DAMAGE; OR BE REPLACED AT THE SUBCONTRACTOR'S EXPENSE. 6. ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, THE SUBCONTRACTOR SHALL USE DILIGENT EFFORTS TO MOUNT EQUIPMENT SUCH THAT IT WILL BE CLEAN, LEVEL, AND SOLID. 7. ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING FINISHES. 8. ANY METAL SHAVINGS RESULTING FROM SITE WORK SHALL BE CLEANED FROM ROOF SURF ACES, ENCLOSURES, AND ANY ADDITIONAL AREAS WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MAY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. 9. BEAMS OR JOISTS SHALL NOT BE DRILLED UNLESS SPECIFICALLY AUTHORIZED BY CONTRACTOR. 10. WHEN MOUNTING EQUIPMENT TO EXISTING REINFORCED CONCRETE, USE CARE TO A VOID CUTTING OR DAMAGING THE REINFORCING BARS. POWER DRIVEN PINS ARE NOT TO BE USED. 11. IF THE OCCUPANCY STRUCTURE IS RESIDENTIAL, IT WILL BE UPGRADED TO CONFORM WITH 2022 CALIFORNIA RESIDENTIAL CODE REQUIREMENTS FOR CARBON MONOXIDE ALARMS (SECTION R315), AND SMOKE DETECTORS. 12. CONTRACTOR SHALL FURNISH ALL SUPERVISION, TEMPORARY FACILITIES, AND OTHER NECESSARY ITEMS AS REQUIRED TO COMPLETE THE WORK SPECIFIED TO PROVIDE A COMPLETE AND USABLE SYSTEM. 13. DRAWINGS ARE DIAGRAMMATIC, SITE CONDITIONS SHALL PREVAIL. IF NO SCALE IS GIVEN, DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR AND SUBCONTRACTORS IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION. 14. SUBCONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT ,JOB SITE AND REPORT ANY DISCREPANCIES TO CONTRACTOR'S SUPERINTENDENT, PROJECT MANAGER OR CONSTRUCTION MANAGER BEFORE COMMENCING WORK. 15. ALL CONDUCTOR SIZES AND TYPES SPECIFIED IN SINGLE LINE AND /OR THREE LINE DIAGRAMS ARE TO BE INSTALLED. OCCUPANCY GROUP - R-3/U TYPE OF CONSTRUCTION (V-B) 1 -STORY HOUSE 1 3 5 ' - 8 " 78'-8" 13 1 ' - 0 " 89'-0" 26 ' - 0 " 2'-5" 13'-5" 8'-11" PW PW BL P GW IN V MS P UM GM RD S IN V MS P UM GM RD S PW PW BL P GW 10 " SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-1 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV PLOT PLAN WITH ROOF PLAN E-1 PLOT PLAN WITH 1 SCALE: 1/16" = 1'-0" ROOF PLAN ALL CEC 110.26 CLEARANCES WILL BE MET FOR NEW EQUIPMENT. ALL NEW ELECTRICAL EQUIPMENT WILL BE MORE THAN 3’ AWAY FROM THE GAS METER’S PRESSURE REGULATOR. PROPERTY LINE PR O P E R T Y L I N E (E) DRIVEWAY (E) FENCE 1-STORY HOUSE (E) CHIMNEY(TYP.) (E) TREES ROOF #1 (13) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (N) TESLA SOLAR 7.6KW 1538000-XX-Y INVERTER (E) 100A MAIN SERVICE PANEL (E) UTILITY METER (N) REMOTE DISABLE SWITCH (E) GAS METER (N) TESLA POWERWALL 2 AC BATTERIES (INSIDE GARAGE) (N) 125A BACKUP LOADS PANEL (N) 200A TESLA BACKUP GATEWAY 2 WITH INTERNAL PANELBOARD AVENTINE CT. (E) DRIVEWAY PR O P E R T Y L I N E PROP E R T Y L I N E ROOF #2 (4) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES ROOF #3 (7) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES ROOF #4 (2) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES 3" 10 ' - 4 " 2' - 4 " 13 ' - 9 " 3' - 0 " 13 ' - 9 " 3' - 0 " 4'-3" 3'-2" 4'-7"3'-6" 10 ' - 4 " 6' - 1 0 " 4' - 1 " 1' - 9 " 6' - 1 0 " 9' - 7 " 1' - 8 " 6' - 1 0 " 5' - 3 " 17 ' - 2 " 3' - 2 " 7'-9"14'-2" 3'-3" 3'-4"3'-7" PW PW BL P GW IN V MS P UM GM RD S 10 " JB 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36" FIRE SETBACK 36 " F I R E S E T B A C K 36" FIRE SETBACK 36 " F I R E S E T B A C K 36" FIRE SETBACK 36" FIRE SETBACK IN V MS P UM GM RD S PW PW BL P GW 10 " SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-2 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV 1 ROOF PLAN & MODULES E-2 SCALE: 3/32" = 1'-0" ROOF PLAN & MODULES DESIGN SPECIFICATION RISK CATEGORY:II CONSTRUCTION:SFD ZONING:RESIDENTIAL SNOW LOAD (ASCE 7-16):0 PSF EXPOSURE CATEGORY:B WIND SPEED (ASCE 7-16):0 MPH LEGEND - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT GW - TESLA BACKUP GATEWAY 2 PW - POWERWALL 2 AC BATTERY UM - UTILITY METER - TRUSS JB - JUNCTION BOX MSP - MAIN SERVICE PANELMODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES:26 MODULES MODULE TYPE:Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULE WEIGHT:45LBS MODULE DIMENSIONS: UNIT WEIGHT OF AREA: PSF 74" x 41.1" = 21.12SF 2.13 INV - INVERTER GM - GAS METER ARRAY AREA & ROOF AREA CALC'S # # TOTAL NO. OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) TOTAL ROOF AREA COVERED BY ARRAY 26 542.36 5533.28 10 (N) JUNCTION BOX ROOF #1, #2, #3 & #4 (26) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (48) IRONRIDGE TILT LEG ATTACHMENTS@ 72" O.C RDS - REMOTE DISABLE SWITCH (N) 3/4" EMT CONDUIT (N) IRONRIDGE XR-10 RAIL AVENTINE CT. BLP - BACKUP LOADS PANEL ROOF DESCRIPTION ROOF ROOF TILT AZIMUTH ROOF MATERIAL RAFTER SIZE RAFTER SPACING #1 1°269°FLAF ROOF 2" x 4"24" @ o.c. #2 2°89°FLAF ROOF 2" x 4"24" @ o.c. #3 2°89°FLAF ROOF 2" x 4"24" @ o.c. #4 1°269°FLAF ROOF 2" x 4"24" @ o.c. (N) TESLA SOLAR 7.6KW 1538000-XX-Y INVERTER (E) 100A MAIN SERVICE PANEL (E) UTILITY METER (N) REMOTE DISABLE SWITCH (E) GAS METER (N) TESLA POWERWALL 2 AC BATTERIES (INSIDE GARAGE) (N) 125A BACKUP LOADS PANEL (N) 200A TESLA BACKUP GATEWAY 2 WITH INTERNAL PANELBOARD (9) TESLA MCI (MID CIRCUIT INTERRUPTER) DESIGN SUMMARY SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-2A 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV GATEWAY 2 INTERNAL PANELBOARD CONFIGURATION 30A,2P POWERWALL 30A,2P POWERWALL 40A,2P (N) SOLAR THE PREINSTALLED GATEWAY 2 CTS WILL BE USED TO MEASURE THE WHOLE HOUSE CONSUMPTION, AND THE TESLA PROVIDED SINGLE CT WILL BE USED TO MEASURE THE SOLAR CIRCUIT. MONITORING NOTES CUSTOMER NOTES VERIFY THAT THE EQUIPMENT LOCATION AND PROPOSED BACK-UP LOADS ARE CORRECT. DURING A POWER OUTAGE, THE HOMEOWNER WILL NEED TO ACTIVELY MANAGE WHICH LOADS ARE BEING USED IN ORDER TO MAXIMIZE THE RUN TIME ON THE BATTERIES. IT IS NOT RECOMMENDED THAT THE EV CHARGER IS USED. IF THE HOMEOWNER DOES NOT WANT TO MANAGE THIS LOAD, WE RECOMMEND MOVING IT TO THE NONBACKUP LOADS. THE LOCATION OF THE EQUIPMENT AND THE CONDUIT RUN WILL BE VERIFIED WITH THE CUSTOMER PRIOR TO THE INSTALLATION.INSTALLATION NOTES BACKUP LOADS ALL CIRCUITS WILL BE BACKED UP. SPECIAL COMPONENTS --# OF SOFT STARTS BR2100 RECOMMENDED COMPONENTS CONNECTING MSP TO GW2 --(N) OCPD FOR (E) SUBPANEL --PREFABRICATED PAD MODEL RECOMMENDATION --PSP RELAY MODEL RECOMMENDATION --LOW VOLTAGE DISCONNECT MODEL --BOLLARDS --NEMA 14-50 OUTLET (240V/50A BREAKER) --INTERLOCK KIT LOADS THAT WILL NOT BE BACKED UP DURING AN OUTAGE (THIS IS THE MAIN SERVICE PANEL BREAKER SCHEDULE AFTER THE INSTALLATION) ------ PROJECT SCOPE (2) TESLA POWERWALL 2 AC BATTERIES SYSTEM (10 KW, 27 KWH) (1) TESLA BACKUP GATEWAY 2 INSTALL NEW INTERNAL PANEL BOARD IN GW 2 TO HOLD NEW AC BATTERY CIRCUIT BREAKERS AND NEW PHOTOVOLTAIC SYSTEM. INSTALL NEW SUB PANEL TO HOLD EXISTING BACKUP LOADS. ALL WORK TO COMPLY WITH: 2022 CALIFORNIA ELECTRICAL CODE. 2022 CALIFORNIA RESIDENTIAL CODE. 2022 CALIFORNIA FIRE CODE. 2022 CALIFORNIA BUILDING CODE. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE. 2022 CALIFORNIA ENERGY CODE. 2022 CALIFORNIA PLUMBING CODE. 2022 CALIFORNIA MECHANICAL CODE. INSTALL ADVANCED ENERGY SYSTEM INCLUDING: PW PW BL P GW IN V MS P UM GM RD S JB 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36" FIRE SETBACK 36 " F I R E S E T B A C K 36" FIRE SETBACK 36 " F I R E S E T B A C K 36" FIRE SETBACK 36" FIRE SETBACK SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-2B 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV 1 STRING LAYOUT E-2B SCALE: 1/8" = 1'-0" STRING LAYOUT - MODULE STRINGINGA AVENTINE CT. B C A-1 A-2 A-3A-4 A-5 A-6 A-7 A-8 B-1 B-2 B-3 B-4 C-2 C-1 B-5 B-6 B-7 C-3 C-4 C-5 C-6 C-7 B-8 B-9 C-8 A-9 T E S L A T E S L A 3' - 9 " 2'-6" 3' - 9 " 2'-6" 3' - 0 " GROUND GROUND 10" B L P 1' - 1 1 " 1'-3" T E S L A GW2 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-2C 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV ELEVATION PLAN (N) TESLA POWERWALL 2 AC BATTERIES(INSIDE GARAGE) 1 ELEVATION PLAN E-2C SCALE: 1/2" = 1'-0" EAST INTERIOR WALL (N) 125A BACKUP LOADS PANEL (N) 200A TESLA BACKUP GATEWAY 2 WITH INTERNAL PANELBOARD IRONRIDGE FRA IRONRIDGE NORTH TILT LEG IRONRIDGE U-FOOT IRONRIDGE SOUTH TILT LEG IRONRIDGE XR-10 RAIL 7" SOUTH TILT LEG IRONRIDGE SOUTH TILT LEG IRONRIDGE XR-10 RAIL MEMBRANE FLASHING IRONRIDGE XR-10 RAIL IRONRIDGE NORTH TILT LEG NUT, FLANGE HEX 3/8-16 SS FLAT ROOF IRONRIDGE FRA IRONRIDGE NORTH TILT LEG IRONRIDGE U-FOOT IRONRIDGE SOUTH TILT LEG MEMBRANE FLASHING 7" SOUTH TILT LEG 15" NORTH TILT LEG SEE (2/E-3) FOR ENLARGED VIEW PV MODULE IRONRIDGE SOUTH TILT LEG FLAT ROOF PV MODULE IRONRIDGE NORTH TILT LEG MEMBRANE FLASHING NUT, FLANGE HEX 3/8-16 SS SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-3 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV ATTACHMENT DETAILS 2 E-3 SCALE: NTS 1 ATTACHMENT DETAILS E-3 ENLARGED VIEW FOR ATTACHMENT DETAILS M CTRL 30A/2P (N) TESLA POWERWALL 5KW, 13.5KWH, NEMA 3R POWERWALL 2 1092170-XX-Y [240V] [SI1-JUN20] + GATEWAY 1118431-XX-X [CRD PCS] (N) BACKUP ENERGY GATEWAY 2 WITH INTERNAL PANELBOARD, 240 VAC, 200A RATED,NEMA 3R, UL LISTED THE PREINSTALLED BONDING JUMPER WILL BE REMOVED FROM THE GATEWAY 30A/2P (N) TESLA POWERWALL 5KW, 13.5KWH, NEMA 3R 40/2P 4 (N) BACKUP LOAD PANEL, 125A RATED, 240V, NEMA 3R 5 100/2P (N) MAIN BREAKER 100A (TOP FED) 12V WIRE (N) REMOTE DISABLE SWITCH, 16A RATED =~(N) JUNCTION BOX, 600V, NEMA 3, UL LISTED (N) TESLA SOLAR 7.6KW 1538000-XX-Y OUTPUT:240VAC, 32A 98% CEC WEIHTED EFFICIENCY NEMA 3R,UL LISTED , INTERNAL GFDI WITH INTEGRATED DC DISCONNECT 3 2 A B C D 2 31 5 64 8 97 2 31 5 64 8 97 TESLA MCI 2 3 5 64 87 (26) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES 1 STRING: 9 MODULES 2 STRING: 9 MODULES 3 STRING: 8 MODULES CT'S FOR WHOLE HOME CONSUMPTION ARE LOCATED IN GATEWAY 705.12 (B) (2) (3) (c): THE SUM OF THE OVERCURRENT PROTECTION DEVICES CANNOT EXCEED THE BUS BAR RATING 705.12 (B) (2) (3) (c): THE SUM OF THE OVERCURRENT PROTECTION DEVICES CANNOT EXCEED THE BUS BAR RATING ESSENTIAL BACKUP CRITICAL CIRCUIT AND APPLIANCES INSTALLED HERE TO BE ISOLATED FROM NON-BACKUP CIRCUIT AND POWERED DURING A UTILITY OUTAGE EVENT BY THE ADVANCED ENERGY STORAGE SYSTEM. SYSTEM WILL MAINTAIN OPERATIONS IN ISLAND MODE AND PROVIDE POWER TO THE ESSENTIAL BACKUP CRITICAL CIRCUTIS AND APPLIANCES DURING A UTILITY OUTAGE EVENT. 1 PREFABRICATED JUMPER LISTED WITH GATEWAY 2 (E) MAIN SERVICE PANEL, 100A RATED, 240 VAC, NEMA 3R M (E) MAIN BREAKER 100A (CENTER FED) TO UTILITY GRID (E) BI-DIRECTIONAL UTILITY METER 1-PHASE, 240 V METER# 222012-132860 100A/2P (N) 100A BREAKER (BR2100) 100A/2P CT 1 6 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-4 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV ELECTRICAL & WIRING CALC. 1 ELECTRICAL LINE DIAGRAM & WIRING CALC. E-4 SCALE: NTS NO BACK-UP LOADS ARE > A IN ACCORDANCE WITH CEC 710.15(A) HOLD DOWN KITS WILL BE USED FOR THE BATTERY BREAKERS PER 408.36(D) IF ANY EXISTING LOAD CONDUCTORS ARE EXTENDED BY MORE THAN 6’, AFCI PROTECTION WILL BE PROVIDED PER CEC 210.12(B)(2). ALL TERMINAL TEMPERATURES OF EQUIPMENT WILL BE VERIFIED TO BE RATED FOR 75°C, OR THE WIRE WILL NEED TO BE RESIZED USING THE 60°C TERMINAL TEMPERATURE RATINGS FOR 100A OR LESS. A SUPPLEMENTAL GROUND ROD WILL BE DRIVEN IN ACCORDANCE WITH CEC 250.53(A)(3) IF THE EXISTING GROUND ROD HAS A RESISTANCE TO EARTH THAT IS GREATER THAN 25 OHMS. THE ESS CIRCUIT BREAKER SHALL BE SECURED IN PLACE BY AN ADDITIONAL FASTENER PER CEC 408.36(D). LABELS FOR EXISTING PV SYSTEMS WILL BE TRANSFERRED OR REPLACED ON NEW EQUIPMENT. PRODUCER’S STORAGE DEVICE(S) WILL NOT CAUSE THE HOST LOAD TO EXCEED ITS NORMAL PEAK DEMAND. NORMAL PEAK DEMAND IS DEFINED AS THE HIGHEST AMOUNT OF POWER REQUIRED FROM THE DISTRIBUTION SYSTEM BY PRODUCER’S COMPLETE FACILITIES WITHOUT THE INFLUENCE OR USE OF THE ENERGY STORAGE DEVICE(S). 60 PER CEC 310.15(B)(7)(2), FEEDER CONDUCTORS SUPPLYING THE ENTIRE LOAD ASSOCIATED WITH A ONE-FAMILY DWELLING SHALL BE PERMITTED TO AN AMPACITY NOT LESS THAN 83% OF THE FEEDER RATING. 65 7 2 31 4 3 4 4 ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT # OF PARALLEL CIRCUITS CONTROL WIRE (HW152 TRAY CABLE - SHIELDED CONTROL WIRE) EGC 1 3 STRING JUNCTION BOX 12 AWG PV WIRE ----1 --6 AWG BARE COPPER 2 1 JUNCTION BOX INVERTER 10 AWG THWN-2 COPPER OR EQUIVALENT MIN 0.75" Dia EMT 3 --10 AWG THWN-2, COPPER OR EQUIVALENT 3 1 INVERTER GATEWAY 2 INTERNAL PANELBOARD 8 AWG THWN-2 COPPER OR EQUIVALENT MIN 0.75" Dia SCH 40 PVC 1 --10 AWG THWN-2, COPPER OR EQUIVALENT 4 1 BATTERY 1 GATEWAY 2 INTERNAL PANELBOARD 8 AWG THWN-2 COPPER OR EQUIVALENT MIN 1" Dia SCH 40 PVC 2 1 10 AWG THWN-2, COPPER OR EQUIVALENT 5 1 GATEWAY 2 BLP 3 AWG THWN-2 COPPER OR EQUIVALENT MIN 1" Dia SCH 40 PVC 1 --8 AWG THWN-2, COPPER OR EQUIVALENT 6 1 GATEWAY 2 MSP 3 AWG THWN-2 COPPER OR EQUIVALENT MIN 1.25" Dia SCH 40 PVC 1 --8 AWG THWN-2, COPPER OR EQUIVALENT 8 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-4A 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV CALCULATION WIRING ID TYPICAL INITIAL CONDUCTOR LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT # OF PARALLEL CIRCUITS CURRENT-CARRYING CONDUCTORS IN CONDUIT CONTROL WIRE (HW152 TRAY CABLE - SHIELDED CONTROL WIRE) CONDUIT FILL PERCENT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT BASE AMP. DERATED AMP. TERM. TEMP. RATING LENGTH VOLTAGE DROP 1 3 STRING JUNCTION BOX 12 AWG PV WIRE ----1 2 --N/A N/A 6 AWG BARE COPPER N/A N/A N/A 15.0A 18.7A N/A N/A 90°C 83FT 0.03% 2 1 JUNCTION BOX INVERTER 10 AWG THWN-2 COPPER OR EQUIVALENT MIN 0.75" Dia EMT 3 6 --26.72%20A 10 AWG THWN-2, COPPER OR EQUIVALENT 0.87 44°C 0.8 15.0A 18.7A 40.0A 27.84A 75°C 20FT 0.07% 3 1 INVERTER GATEWAY 2 INTERNAL PANELBOARD 8 AWG THWN-2 COPPER OR EQUIVALENT MIN 0.75" Dia SCH 40 PVC 1 3 --25.07%40A 10 AWG THWN-2, COPPER OR EQUIVALENT 0.87 44°C 1 32.0A 40.0A 55.0A 47.85A 75°C 3FT 0.07% 4 1 BATTERY 1 GATEWAY 2 INTERNAL PANELBOARD 8 AWG THWN-2 COPPER OR EQUIVALENT MIN 1" Dia SCH 40 PVC 2 4 1 30.50%30A 10 AWG THWN-2, COPPER OR EQUIVALENT 0.87 44°C 0.8 24.0A 30.0A 55.0A 38.28A 75°C 4FT 0.07% 5 1 GATEWAY 2 BLP 3 AWG THWN-2 COPPER OR EQUIVALENT MIN 1" Dia SCH 40 PVC 1 3 --38.20%100A 8 AWG THWN-2, COPPER OR EQUIVALENT 0.87 44°C 1 80.0A 100.0A 115.0A 100.05A 75°C 2FT 0.03% 6 1 GATEWAY 2 MSP 3 AWG THWN-2 COPPER OR EQUIVALENT MIN 1" Dia SCH 40 PVC 1 3 --38.20%100A 8 AWG THWN-2, COPPER OR EQUIVALENT 0.87 44°C 1 80.0A 100.0A 115.0A 100.05A 75°C 2FT 0.03% SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-5 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV PLACARDS NOTES 1.CEC ARTICLES 690 AND 705 AND CRC SECTION R331 MARKINGS SHOW HEREON 2.ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING B.RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK C.ARIAL FONT. 3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. 4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING POP-RIVETS OR SCREWS. 5.THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. 6.WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4. 7.ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. PLACARDS POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN. CAUTION! 6 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL LOCATION: AT THE LOCATION OF C-CODE (MSP, SUBPANEL, GATEWAY) 4 WARNING THIS EQUIPEMNT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. LABEL LOCATION: PV BREAKERS 2 PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE 1 BATTERY DISCONNECT DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: BATTERY BREAKERS support@swellenergy.com 310-340-0493 LABEL LOCATION: POWERWALL BREAKER 5 WARNING ARC FLASH & SHOCK HAZARD NOMINALESS VOLATAGE: 240V MAX SHORT-CIRCUIT CURRENT: 32A ASSOCIATED CLEARING TIME: 60ms DATE CALCULATION WAS PERFORMED: 41.7ABATTERY SYSTEM RATED AC OUTPUT CURRENT PV SYSTEM RATED AC OUTPUT CURRENT PV SYSTEM RATED AC OUTPUT VOLTAGE PV SYSTEM POWER PHASE 240V SINGLE 32A 06/14/2023 WARNING FUEL CELL POWER SYSTEM CONTAINS ELECTRICAL ENERGY STORAGE DEVICES LABEL LOCATION: AT THE LOCATION OF THE SERVICE DISCONNECTING. ! CAUTION: STORAGE SYSTEM DISCONNECT LABEL LOCATION: AT THE LOCATION OF THE SERVICE DISCONNECTING. 7 LABEL LOCATION: MAIN SERVICE PANEL IF MSD IS OUTSIDE PLACE IT THERE / IF MSD IS INSIDE PLACE ON THE AC DISCONNECT. 8 41743 AVENTINE CT. PALM DESERT CA 92260 3 LABEL LOCATION: SUB PANEL OR BACKUP LOADS PANEL, BATTERY, INVERTER OUTPUT PANEL, MAIN SERVICE PANEL, METER/MAIN, AND PV AC DISCONNECT CAUTION-TRI POWER SOURCE FIRST SOURCE IS UTILITY ELECTRICAL GRID SECOND SOURCE IS AC BATTERY THIRD SOURCE IS PV INVERTER PV INVERTER MAIN SERVICE DISCONNECT BATTERY DISCONNECT AC BATTERIES ROOFTOP PV MODULES & TESLA MCI FR O N T O F H O U S E PW PW BL P GW IN V MS P UM GM RD S JB 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K 36" FIRE SETBACK 36 " F I R E S E T B A C K 36" FIRE SETBACK 36 " F I R E S E T B A C K 36" FIRE SETBACK 36" FIRE SETBACK SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-6 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV SAFETY PLAN SAFETY PLAN INSTRUCTION: 1. USE SYMBOLS IN KEY TO MARK UP JOB SHEET 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3. DOCUMENT ALL ADDITIONAL HAZARD ON THIS PAGE AND MAKE NOTES ON THE JCO SHEET IN CASE OF EMERGENCY: NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC: NAME ________________________________________________ ADDRESS_____________________________________________ SAFETY COACH CONTACT INFORMATION NAME ________________________________________________ PHONE_______________________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF HE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE MARK UP KEY P T D G IL AL B S PERMANENT ANCHOR TEMPORARY ANCHOR DELINEATOR FOR MAPPING LINE (LOW SLOPE ROOF RAIL ONLY) GUARD RAIL STANCHON (LOW SLOPE ROOF RAIL ONLY) INSTALLER LADDER AUDITOR LADDER JUNCTION BOX STUBOUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTION) RESTRICTED AREA (EMPLOYEES ONLY) CONDUIT DATE:TIME: SELECT ELECTRICAL TIE IN METHOD MAIN/SUB BREAKER / TAP GAS H2O 7 Z GAS SHUTOFF WATER SHUTOFF SERVICE DROP POWER LINES 1 SAFETY PLAN E-6 SCALE: 3/32" = 1'-0" MOUNTING PLANS PERMANENT ANCHORS TEMPORARY SPACING SPACING MP1 TOTAL AVENTINE CT. SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-7 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-8 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-9 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-10 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-11 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-12 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-13 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-14 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-15 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-16 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-17 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-18 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV EQUIPMENT SPECIFICATION SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-19 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV ANCHORAGE DETAIL SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-20 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV ANCHORAGE DETAIL SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" PROJECT NAME & ADDRESS E-21 41 7 4 3 AV E N T I N E C T . PA L M D E S E R T , CA 92 2 6 0 KA C I E G O E T T S C H R E S I D E N C E DATE: 06/14/2023 REV BYDATEDESCRIPTION REVISIONS AP N : 62 2 0 5 1 0 6 3 PH # : (7 0 2 ) 4 3 9 - 2 9 5 9 EM A I L : ka c i e g o e t t s c h @ y a h o o . c o m CO N T R A C T O R N A M E : SW E L L S E R V I C E S I N C . DB A S W E L L C O N T R A C T O R S 15 1 5 7 T H S T # 4 9 , SA N T A M O N I C A , C A , 9 0 4 0 1 PH # : ( 3 1 0 ) - 3 4 0 - 0 4 9 3 CS L B L I C . # 1 0 2 1 1 8 3 AH J : PA L M D E S E R T C I T Y REV ANCHORAGE DETAIL