HomeMy WebLinkAbout_SOLR23-0971_Kacie Goettsch Residence_15923 PlanSetSHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-0
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
1
2
HOUSE PHOTO
VICINITY MAP SCALE: NTSE-0
E-0 SCALE: NTS
PROJECT SITE
COVER PAGE
PROJECT SITE
SCOPE OF WORK
TO INSTALL A TESLA BATTERY PACK SYSTEM WITH PHOTOVOLTAIC SYSTEM AT THE
OWNER RESIDENCE LOCATED AT 41743 AVENTINE CT. PALM DESERT CA 92260
INSTALL ADVANCED ENERGY SYSTEM WITH PV SYSTEM:
(2) TESLA POWERWALL 2 AC BATTERIES SYSTEM (10KW, 27KWH)
(1) TESLA BACKUP GATEWAY 2 WITH INTERNAL PANELBOARD
(26) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES
(1) TESLA SOLAR 7.6KW 1538000-XX-Y INVERTER
(9) TESLA MCI (MID CIRCUIT INTERRUPTER)
(1) BACKUP LOAD PANEL
(1) REMOTE DISABLE SWITCH
APPLICABLE CODES & STANDARDS
2022 CALIFORNIA ELECTRICAL CODE.
2022 CALIFORNIA RESIDENTIAL CODE.
2022 CALIFORNIA FIRE CODE.
2022 CALIFORNIA BUILDING CODE.
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE.
2022 CALIFORNIA ENERGY CODE.
2022 CALIFORNIA PLUMBING CODE.
2022 CALIFORNIA MECHANICAL CODE.SYSTEM RATING
10.40 KWDC
7.6 KWAC
SHEET INDEX
E-0 COVER PAGE
E-1 PLOT PLAN WITH ROOF PLAN
E-2 ROOF PLAN & MODULES
E-2A DESIGN SUMMARY
E-2B STRING LAYOUT
E-2C ELEVATION PLAN
E-3 ATTACHMENT DETAIL
E-4 ELECTRICAL LINE DIAGRAM & CALCS.
E-4A WIRING CALCULATION
E-5 WARNING LABEL & PLACARDS
E-6 SAFETY PLAN
E-7+EQUIPMENT SPECIFICATIONS
E-19+POWERWALL ANCHORAGE DETAIL
GENERAL NOTES:
1. THESE NOTES SET MINIMUM STANDARDS FOR CONSTRUCTION. THE DRAWINGS GOVERN OVER THESE NOTES TO THE EXTENT SHOWN. ALL WORK
SHALL CONFORM TO THE MINIMUM STANDARDS OF THE FOLLOWING: LOCAL BUILDING CODE, LOCAL ELECTRICAL CODE, ANY PORTION OF THE
WORK AND THOSE CODES AND STANDARDS LISTED IN THESE DRAWINGS AND IN THE SUBCONTRACTOR AGREEMENT. REFER TO REFERENCE
DOCUMENTS LIST.
2. COORDINATE THESE DRAWINGS WITH SPECIFICATIONS AND MANUFACTURER'S INSTALLATION AND OPERATION MANUALS AND NOTIFY
CONTRACTOR OF ANY DISCREPANCIES PRIOR TO BEGINNING WORK.
3. PRIOR TO THE COMMENCEMENT OF ANY WORK, EACH TRADE SHALL VERIFY EXISTING CONDITIONS AND NOTIFY CONTRACTOR OF ANY
DISCREPANCIES TO THAT WHICH IS SHOWN IN THESE DRAWINGS, INCLUDING BUT NOT LIMITED TO DIMENSIONS OF THE WORK AREA, STRUCTURE,
EXISTING ELECTRICAL SERVICE, CONDUIT PATHS, OBSTRUCTIONS, ACCESSIBILITY ISSUES, AND WORKING CLEARANCES. UNLESS INDICATED AS
EXISTING (E), ALL PROPOSED MATERIALS AND EQUIPMENT ARE NEW.
4. MAINTAIN CONTINUITY OF ALL EXISTING CIRCUITS OR PORTIONS THEREOF AFFECTED BY NEW WORK.
5. ALL ITEMS TO BE REMOVED AND RELOCATED OR REPLACED SHALL BE HANDLED WITH PROPER CARE AND STORED IN A SAFE PLACE TO PREVENT
DAMAGE; OR BE REPLACED AT THE SUBCONTRACTOR'S EXPENSE.
6. ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, THE SUBCONTRACTOR SHALL USE DILIGENT EFFORTS TO
MOUNT EQUIPMENT SUCH THAT IT WILL BE CLEAN, LEVEL, AND SOLID.
7. ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT TO MATCH EXISTING FINISHES.
8. ANY METAL SHAVINGS RESULTING FROM SITE WORK SHALL BE CLEANED FROM ROOF SURF ACES, ENCLOSURES, AND ANY ADDITIONAL AREAS
WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MAY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE.
9. BEAMS OR JOISTS SHALL NOT BE DRILLED UNLESS SPECIFICALLY AUTHORIZED BY CONTRACTOR.
10. WHEN MOUNTING EQUIPMENT TO EXISTING REINFORCED CONCRETE, USE CARE TO A VOID CUTTING OR DAMAGING THE REINFORCING BARS.
POWER DRIVEN PINS ARE NOT TO BE USED.
11. IF THE OCCUPANCY STRUCTURE IS RESIDENTIAL, IT WILL BE UPGRADED TO CONFORM WITH 2022 CALIFORNIA RESIDENTIAL CODE REQUIREMENTS
FOR CARBON MONOXIDE ALARMS (SECTION R315), AND SMOKE DETECTORS.
12. CONTRACTOR SHALL FURNISH ALL SUPERVISION, TEMPORARY FACILITIES, AND OTHER NECESSARY ITEMS AS REQUIRED TO COMPLETE THE
WORK SPECIFIED TO PROVIDE A COMPLETE AND USABLE SYSTEM.
13. DRAWINGS ARE DIAGRAMMATIC, SITE CONDITIONS SHALL PREVAIL. IF NO SCALE IS GIVEN, DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL
BE VERIFIED BY SUBCONTRACTOR AND SUBCONTRACTORS IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION.
14. SUBCONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT ,JOB SITE AND REPORT ANY DISCREPANCIES TO
CONTRACTOR'S SUPERINTENDENT, PROJECT MANAGER OR CONSTRUCTION MANAGER BEFORE COMMENCING WORK.
15. ALL CONDUCTOR SIZES AND TYPES SPECIFIED IN SINGLE LINE AND /OR THREE LINE DIAGRAMS ARE TO BE INSTALLED.
OCCUPANCY GROUP - R-3/U
TYPE OF CONSTRUCTION (V-B)
1 -STORY HOUSE
1
3
5
'
-
8
"
78'-8"
13
1
'
-
0
"
89'-0"
26
'
-
0
"
2'-5"
13'-5"
8'-11"
PW
PW
BL
P
GW
IN
V
MS
P
UM
GM
RD
S
IN
V
MS
P
UM
GM
RD
S
PW
PW
BL
P
GW
10
"
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-1
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
PLOT PLAN WITH ROOF PLAN
E-1
PLOT PLAN WITH
1
SCALE: 1/16" = 1'-0"
ROOF PLAN
ALL CEC 110.26 CLEARANCES WILL BE MET FOR NEW EQUIPMENT.
ALL NEW ELECTRICAL EQUIPMENT WILL BE MORE THAN 3’ AWAY
FROM THE GAS METER’S PRESSURE REGULATOR.
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
(E) DRIVEWAY
(E) FENCE
1-STORY
HOUSE
(E) CHIMNEY(TYP.)
(E) TREES
ROOF #1
(13) Q CELLS Q.PEAK DUO BLK ML-G10+
(400W) MODULES
(N) TESLA SOLAR 7.6KW
1538000-XX-Y INVERTER
(E) 100A MAIN SERVICE PANEL
(E) UTILITY METER
(N) REMOTE DISABLE SWITCH
(E) GAS METER
(N) TESLA POWERWALL 2 AC
BATTERIES (INSIDE GARAGE)
(N) 125A BACKUP LOADS PANEL
(N) 200A TESLA BACKUP GATEWAY 2
WITH INTERNAL PANELBOARD
AVENTINE CT.
(E) DRIVEWAY
PR
O
P
E
R
T
Y
L
I
N
E
PROP
E
R
T
Y
L
I
N
E
ROOF #2
(4) Q CELLS Q.PEAK DUO BLK ML-G10+
(400W) MODULES
ROOF #3
(7) Q CELLS Q.PEAK DUO BLK ML-G10+
(400W) MODULES
ROOF #4
(2) Q CELLS Q.PEAK DUO BLK ML-G10+
(400W) MODULES
3"
10
'
-
4
"
2'
-
4
"
13
'
-
9
"
3'
-
0
"
13
'
-
9
"
3'
-
0
"
4'-3"
3'-2"
4'-7"3'-6"
10
'
-
4
"
6'
-
1
0
"
4'
-
1
"
1'
-
9
"
6'
-
1
0
"
9'
-
7
"
1'
-
8
"
6'
-
1
0
"
5'
-
3
"
17
'
-
2
"
3'
-
2
"
7'-9"14'-2"
3'-3"
3'-4"3'-7"
PW
PW
BL
P
GW
IN
V
MS
P
UM
GM
RD
S
10
"
JB
36
"
F
I
R
E
S
E
T
B
A
C
K
36
"
F
I
R
E
S
E
T
B
A
C
K
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36" FIRE SETBACK
IN
V
MS
P
UM
GM
RD
S
PW
PW
BL
P
GW
10
"
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-2
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
1 ROOF PLAN & MODULES
E-2 SCALE: 3/32" = 1'-0"
ROOF PLAN &
MODULES
DESIGN SPECIFICATION
RISK CATEGORY:II
CONSTRUCTION:SFD
ZONING:RESIDENTIAL
SNOW LOAD (ASCE 7-16):0 PSF
EXPOSURE CATEGORY:B
WIND SPEED (ASCE 7-16):0 MPH
LEGEND
- VENT, ATTIC FAN (ROOF OBSTRUCTION)
- ROOF ATTACHMENT
GW - TESLA BACKUP GATEWAY 2
PW - POWERWALL 2 AC BATTERY
UM - UTILITY METER
- TRUSS
JB - JUNCTION BOX
MSP - MAIN SERVICE PANELMODULE TYPE, DIMENSIONS & WEIGHT
NUMBER OF MODULES:26 MODULES
MODULE TYPE:Q CELLS Q.PEAK DUO
BLK ML-G10+ (400W)
MODULE WEIGHT:45LBS
MODULE DIMENSIONS:
UNIT WEIGHT OF AREA: PSF
74" x 41.1" = 21.12SF
2.13
INV - INVERTER
GM - GAS METER
ARRAY AREA & ROOF AREA CALC'S
#
# TOTAL
NO. OF
MODULES
ARRAY
AREA
(Sq. Ft.)
ROOF
AREA
(Sq. Ft.)
ROOF
AREA
COVERED BY
ARRAY (%)
TOTAL
ROOF
AREA
COVERED
BY ARRAY
26 542.36 5533.28 10
(N) JUNCTION BOX
ROOF #1, #2, #3 & #4
(26) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W)
MODULES
(48) IRONRIDGE TILT LEG ATTACHMENTS@ 72" O.C
RDS - REMOTE DISABLE SWITCH
(N) 3/4" EMT CONDUIT
(N) IRONRIDGE XR-10 RAIL
AVENTINE CT.
BLP - BACKUP LOADS PANEL
ROOF DESCRIPTION
ROOF ROOF
TILT AZIMUTH ROOF MATERIAL RAFTER
SIZE
RAFTER
SPACING
#1 1°269°FLAF ROOF 2" x 4"24" @ o.c.
#2 2°89°FLAF ROOF 2" x 4"24" @ o.c.
#3 2°89°FLAF ROOF 2" x 4"24" @ o.c.
#4 1°269°FLAF ROOF 2" x 4"24" @ o.c.
(N) TESLA SOLAR 7.6KW
1538000-XX-Y INVERTER
(E) 100A MAIN SERVICE PANEL
(E) UTILITY METER
(N) REMOTE DISABLE SWITCH
(E) GAS METER
(N) TESLA POWERWALL 2 AC
BATTERIES (INSIDE GARAGE)
(N) 125A BACKUP LOADS PANEL
(N) 200A TESLA BACKUP GATEWAY 2
WITH INTERNAL PANELBOARD
(9) TESLA MCI (MID CIRCUIT INTERRUPTER)
DESIGN
SUMMARY
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-2A
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
GATEWAY 2 INTERNAL PANELBOARD CONFIGURATION
30A,2P POWERWALL
30A,2P POWERWALL
40A,2P (N) SOLAR
THE PREINSTALLED GATEWAY 2 CTS WILL BE USED TO MEASURE THE WHOLE HOUSE
CONSUMPTION, AND THE TESLA PROVIDED SINGLE CT WILL BE USED TO MEASURE THE
SOLAR CIRCUIT.
MONITORING NOTES
CUSTOMER NOTES
VERIFY THAT THE EQUIPMENT LOCATION AND PROPOSED BACK-UP LOADS ARE
CORRECT.
DURING A POWER OUTAGE, THE HOMEOWNER WILL NEED TO ACTIVELY MANAGE WHICH
LOADS ARE BEING USED IN ORDER TO MAXIMIZE THE RUN TIME ON THE BATTERIES. IT
IS NOT RECOMMENDED THAT THE EV CHARGER IS USED. IF THE HOMEOWNER DOES
NOT WANT TO MANAGE THIS LOAD, WE RECOMMEND MOVING IT TO THE NONBACKUP
LOADS.
THE LOCATION OF THE EQUIPMENT AND THE CONDUIT RUN WILL BE VERIFIED
WITH THE CUSTOMER PRIOR TO THE INSTALLATION.INSTALLATION NOTES
BACKUP LOADS ALL CIRCUITS WILL BE BACKED UP.
SPECIAL
COMPONENTS
--# OF SOFT STARTS
BR2100 RECOMMENDED COMPONENTS CONNECTING MSP TO GW2
--(N) OCPD FOR (E) SUBPANEL
--PREFABRICATED PAD MODEL RECOMMENDATION
--PSP RELAY MODEL RECOMMENDATION
--LOW VOLTAGE DISCONNECT MODEL
--BOLLARDS
--NEMA 14-50 OUTLET (240V/50A BREAKER)
--INTERLOCK KIT
LOADS THAT WILL NOT BE BACKED UP DURING AN OUTAGE
(THIS IS THE MAIN SERVICE PANEL BREAKER SCHEDULE
AFTER THE INSTALLATION)
------
PROJECT SCOPE
(2) TESLA POWERWALL 2 AC BATTERIES SYSTEM (10 KW, 27 KWH)
(1) TESLA BACKUP GATEWAY 2
INSTALL NEW INTERNAL PANEL BOARD IN GW 2 TO HOLD NEW
AC BATTERY CIRCUIT BREAKERS AND NEW
PHOTOVOLTAIC SYSTEM.
INSTALL NEW SUB PANEL TO HOLD EXISTING BACKUP LOADS.
ALL WORK TO COMPLY WITH:
2022 CALIFORNIA ELECTRICAL CODE.
2022 CALIFORNIA RESIDENTIAL CODE.
2022 CALIFORNIA FIRE CODE.
2022 CALIFORNIA BUILDING CODE.
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE.
2022 CALIFORNIA ENERGY CODE.
2022 CALIFORNIA PLUMBING CODE.
2022 CALIFORNIA MECHANICAL CODE.
INSTALL ADVANCED ENERGY SYSTEM INCLUDING:
PW
PW
BL
P
GW
IN
V
MS
P
UM
GM
RD
S
JB
36
"
F
I
R
E
S
E
T
B
A
C
K
36
"
F
I
R
E
S
E
T
B
A
C
K
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36" FIRE SETBACK
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-2B
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
1 STRING LAYOUT
E-2B SCALE: 1/8" = 1'-0"
STRING
LAYOUT
- MODULE STRINGINGA
AVENTINE CT.
B C
A-1
A-2
A-3A-4
A-5
A-6
A-7
A-8
B-1
B-2
B-3
B-4
C-2
C-1
B-5
B-6
B-7
C-3
C-4
C-5
C-6
C-7
B-8
B-9
C-8
A-9
T E S L A T E S L A
3'
-
9
"
2'-6"
3'
-
9
"
2'-6"
3'
-
0
"
GROUND GROUND
10"
B L P
1'
-
1
1
"
1'-3"
T E S L A
GW2
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-2C
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
ELEVATION
PLAN
(N) TESLA POWERWALL 2 AC
BATTERIES(INSIDE GARAGE)
1 ELEVATION PLAN
E-2C SCALE: 1/2" = 1'-0"
EAST INTERIOR WALL
(N) 125A BACKUP LOADS PANEL
(N) 200A TESLA BACKUP GATEWAY 2
WITH INTERNAL PANELBOARD
IRONRIDGE FRA
IRONRIDGE NORTH TILT LEG
IRONRIDGE U-FOOT
IRONRIDGE SOUTH TILT LEG
IRONRIDGE XR-10 RAIL
7" SOUTH
TILT LEG
IRONRIDGE
SOUTH TILT LEG
IRONRIDGE XR-10 RAIL
MEMBRANE FLASHING
IRONRIDGE XR-10 RAIL
IRONRIDGE
NORTH TILT LEG
NUT, FLANGE HEX 3/8-16 SS
FLAT ROOF
IRONRIDGE FRA
IRONRIDGE NORTH TILT LEG
IRONRIDGE U-FOOT
IRONRIDGE SOUTH TILT LEG
MEMBRANE FLASHING
7" SOUTH
TILT LEG
15" NORTH
TILT LEG
SEE (2/E-3) FOR ENLARGED VIEW
PV MODULE
IRONRIDGE
SOUTH TILT LEG
FLAT ROOF
PV MODULE
IRONRIDGE
NORTH TILT LEG
MEMBRANE FLASHING
NUT, FLANGE HEX 3/8-16 SS
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-3
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
ATTACHMENT
DETAILS
2
E-3 SCALE: NTS
1 ATTACHMENT DETAILS
E-3
ENLARGED VIEW FOR ATTACHMENT DETAILS
M
CTRL
30A/2P
(N) TESLA POWERWALL
5KW, 13.5KWH, NEMA 3R
POWERWALL 2 1092170-XX-Y
[240V] [SI1-JUN20] + GATEWAY
1118431-XX-X [CRD PCS]
(N) BACKUP ENERGY
GATEWAY 2 WITH INTERNAL
PANELBOARD, 240 VAC, 200A
RATED,NEMA 3R, UL LISTED
THE PREINSTALLED BONDING JUMPER
WILL BE REMOVED FROM THE GATEWAY
30A/2P
(N) TESLA POWERWALL
5KW, 13.5KWH, NEMA 3R
40/2P
4
(N) BACKUP LOAD PANEL, 125A
RATED, 240V, NEMA 3R
5
100/2P
(N) MAIN BREAKER 100A
(TOP FED)
12V WIRE
(N) REMOTE DISABLE
SWITCH, 16A RATED
=~(N) JUNCTION BOX,
600V, NEMA 3, UL LISTED
(N) TESLA SOLAR 7.6KW 1538000-XX-Y
OUTPUT:240VAC, 32A
98% CEC WEIHTED EFFICIENCY
NEMA 3R,UL LISTED , INTERNAL GFDI
WITH INTEGRATED DC DISCONNECT
3
2
A
B
C
D
2 31 5 64 8 97
2 31 5 64 8 97
TESLA MCI
2 3 5 64 87
(26) Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES
1 STRING: 9 MODULES
2 STRING: 9 MODULES
3 STRING: 8 MODULES
CT'S FOR WHOLE HOME CONSUMPTION
ARE LOCATED IN GATEWAY
705.12 (B) (2) (3) (c): THE SUM OF THE
OVERCURRENT PROTECTION DEVICES
CANNOT EXCEED THE BUS BAR RATING
705.12 (B) (2) (3) (c): THE SUM OF THE
OVERCURRENT PROTECTION DEVICES
CANNOT EXCEED THE BUS BAR RATING
ESSENTIAL BACKUP CRITICAL CIRCUIT AND
APPLIANCES INSTALLED HERE TO BE ISOLATED
FROM NON-BACKUP CIRCUIT AND POWERED
DURING A UTILITY OUTAGE EVENT BY THE
ADVANCED ENERGY STORAGE SYSTEM.
SYSTEM WILL MAINTAIN OPERATIONS IN
ISLAND MODE AND PROVIDE POWER TO
THE ESSENTIAL BACKUP CRITICAL
CIRCUTIS AND APPLIANCES DURING A
UTILITY OUTAGE EVENT.
1
PREFABRICATED JUMPER
LISTED WITH GATEWAY 2
(E) MAIN SERVICE PANEL, 100A
RATED, 240 VAC, NEMA 3R
M
(E) MAIN BREAKER 100A
(CENTER FED)
TO UTILITY GRID
(E) BI-DIRECTIONAL
UTILITY METER
1-PHASE, 240 V
METER# 222012-132860 100A/2P
(N) 100A BREAKER
(BR2100)
100A/2P
CT
1
6
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-4
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
ELECTRICAL &
WIRING CALC.
1 ELECTRICAL LINE DIAGRAM & WIRING CALC.
E-4 SCALE: NTS
NO BACK-UP LOADS ARE > A IN ACCORDANCE WITH CEC
710.15(A)
HOLD DOWN KITS WILL BE USED FOR THE BATTERY
BREAKERS PER 408.36(D)
IF ANY EXISTING LOAD CONDUCTORS ARE EXTENDED BY
MORE THAN 6’, AFCI PROTECTION WILL BE PROVIDED PER
CEC 210.12(B)(2).
ALL TERMINAL TEMPERATURES OF EQUIPMENT WILL BE
VERIFIED TO BE RATED FOR 75°C, OR THE WIRE WILL NEED
TO BE RESIZED USING THE 60°C TERMINAL TEMPERATURE
RATINGS FOR 100A OR LESS.
A SUPPLEMENTAL GROUND ROD WILL BE DRIVEN IN
ACCORDANCE WITH CEC 250.53(A)(3) IF THE EXISTING
GROUND ROD HAS A RESISTANCE TO EARTH THAT IS
GREATER THAN 25 OHMS.
THE ESS CIRCUIT BREAKER SHALL BE SECURED IN PLACE
BY AN ADDITIONAL FASTENER PER CEC 408.36(D).
LABELS FOR EXISTING PV SYSTEMS WILL BE TRANSFERRED
OR REPLACED ON NEW EQUIPMENT.
PRODUCER’S STORAGE DEVICE(S) WILL NOT CAUSE THE
HOST LOAD TO EXCEED ITS NORMAL PEAK DEMAND.
NORMAL PEAK DEMAND IS DEFINED AS THE HIGHEST
AMOUNT OF POWER REQUIRED FROM THE DISTRIBUTION
SYSTEM BY PRODUCER’S COMPLETE FACILITIES WITHOUT
THE INFLUENCE OR USE OF THE ENERGY STORAGE
DEVICE(S).
60
PER CEC 310.15(B)(7)(2), FEEDER CONDUCTORS SUPPLYING THE ENTIRE
LOAD ASSOCIATED WITH A ONE-FAMILY DWELLING SHALL BE PERMITTED TO
AN AMPACITY NOT LESS THAN 83% OF THE FEEDER RATING.
65 7
2 31 4
3 4
4
ID TYPICAL INITIAL CONDUCTOR
LOCATION FINAL CONDUCTOR LOCATION CONDUCTOR CONDUIT
# OF
PARALLEL
CIRCUITS
CONTROL WIRE (HW152
TRAY CABLE - SHIELDED
CONTROL WIRE)
EGC
1 3 STRING JUNCTION BOX 12 AWG PV WIRE ----1 --6 AWG BARE COPPER
2 1 JUNCTION BOX INVERTER 10 AWG THWN-2 COPPER OR EQUIVALENT MIN 0.75" Dia EMT 3 --10 AWG THWN-2, COPPER OR
EQUIVALENT
3 1 INVERTER GATEWAY 2 INTERNAL
PANELBOARD 8 AWG THWN-2 COPPER OR EQUIVALENT MIN 0.75" Dia SCH 40 PVC 1 --10 AWG THWN-2, COPPER OR
EQUIVALENT
4 1 BATTERY 1 GATEWAY 2 INTERNAL
PANELBOARD 8 AWG THWN-2 COPPER OR EQUIVALENT MIN 1" Dia SCH 40 PVC 2 1 10 AWG THWN-2, COPPER OR
EQUIVALENT
5 1 GATEWAY 2 BLP 3 AWG THWN-2 COPPER OR EQUIVALENT MIN 1" Dia SCH 40 PVC 1 --8 AWG THWN-2, COPPER OR
EQUIVALENT
6 1 GATEWAY 2 MSP 3 AWG THWN-2 COPPER OR EQUIVALENT MIN 1.25" Dia SCH 40 PVC 1 --8 AWG THWN-2, COPPER OR
EQUIVALENT
8
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-4A
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
CALCULATION
WIRING
ID TYPICAL
INITIAL
CONDUCTOR
LOCATION
FINAL
CONDUCTOR
LOCATION
CONDUCTOR CONDUIT
# OF
PARALLEL
CIRCUITS
CURRENT-CARRYING
CONDUCTORS IN
CONDUIT
CONTROL WIRE
(HW152 TRAY
CABLE -
SHIELDED
CONTROL WIRE)
CONDUIT
FILL
PERCENT
OCPD EGC TEMP. CORR.
FACTOR
CONDUIT
FILL
FACTOR
CONT.
CURRENT
MAX.
CURRENT
BASE
AMP.
DERATED
AMP.
TERM.
TEMP.
RATING
LENGTH VOLTAGE
DROP
1 3 STRING JUNCTION BOX 12 AWG PV WIRE ----1 2 --N/A N/A 6 AWG BARE COPPER N/A N/A N/A 15.0A 18.7A N/A N/A 90°C 83FT 0.03%
2 1 JUNCTION BOX INVERTER 10 AWG THWN-2 COPPER OR
EQUIVALENT
MIN 0.75" Dia
EMT 3 6 --26.72%20A 10 AWG
THWN-2,
COPPER OR
EQUIVALENT
0.87 44°C 0.8 15.0A 18.7A 40.0A 27.84A 75°C 20FT 0.07%
3 1 INVERTER
GATEWAY 2
INTERNAL
PANELBOARD
8 AWG THWN-2 COPPER OR
EQUIVALENT
MIN 0.75" Dia
SCH 40 PVC 1 3 --25.07%40A 10 AWG
THWN-2,
COPPER OR
EQUIVALENT
0.87 44°C 1 32.0A 40.0A 55.0A 47.85A 75°C 3FT 0.07%
4 1 BATTERY 1
GATEWAY 2
INTERNAL
PANELBOARD
8 AWG THWN-2 COPPER OR
EQUIVALENT
MIN 1" Dia SCH
40 PVC 2 4 1 30.50%30A 10 AWG
THWN-2,
COPPER OR
EQUIVALENT
0.87 44°C 0.8 24.0A 30.0A 55.0A 38.28A 75°C 4FT 0.07%
5 1 GATEWAY 2 BLP 3 AWG THWN-2 COPPER OR
EQUIVALENT
MIN 1" Dia SCH
40 PVC 1 3 --38.20%100A 8 AWG
THWN-2,
COPPER OR
EQUIVALENT
0.87 44°C 1 80.0A 100.0A 115.0A 100.05A 75°C 2FT 0.03%
6 1 GATEWAY 2 MSP 3 AWG THWN-2 COPPER OR
EQUIVALENT
MIN 1" Dia SCH
40 PVC 1 3 --38.20%100A 8 AWG
THWN-2,
COPPER OR
EQUIVALENT
0.87 44°C 1 80.0A 100.0A 115.0A 100.05A 75°C 2FT 0.03%
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-5
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
PLACARDS NOTES
1.CEC ARTICLES 690 AND 705 AND CRC SECTION R331 MARKINGS SHOW HEREON
2.ALL MARKINGS SHALL CONSIST OF THE FOLLOWING:
A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR
ELECTRO-PLATING
B.RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK
C.ARIAL FONT.
3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED.
4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING POP-RIVETS OR SCREWS.
5.THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.
6.WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS AND MARKINGS
SHOULD COMPLY WITH ANSI Z535.4.
7.ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE
WEATHER RESISTANT.
PLACARDS
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS LOCATED AS SHOWN.
CAUTION!
6
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR ELECTRIC
PV PANELS
LABEL LOCATION:
AT THE LOCATION OF C-CODE (MSP,
SUBPANEL, GATEWAY)
4 WARNING
THIS EQUIPEMNT FED BY MULTIPLE SOURCES.
TOTAL RATING OF ALL OVERCURRENT DEVICES,
EXCLUDING MAIN SUPPLY OVERCURRENT DEVICES
SHALL NOT EXCEED AMPACITY OF BUSBAR.
LABEL LOCATION:
PV BREAKERS
2 PV SOLAR BREAKER
DO NOT RELOCATE
THIS OVERCURRENT
DEVICE
1 BATTERY DISCONNECT
DO NOT RELOCATE
THIS OVERCURRENT
DEVICE
LABEL LOCATION:
BATTERY BREAKERS
support@swellenergy.com
310-340-0493
LABEL LOCATION:
POWERWALL BREAKER
5
WARNING ARC FLASH & SHOCK HAZARD
NOMINALESS VOLATAGE: 240V
MAX SHORT-CIRCUIT CURRENT: 32A
ASSOCIATED CLEARING TIME: 60ms
DATE CALCULATION WAS PERFORMED:
41.7ABATTERY SYSTEM RATED AC OUTPUT CURRENT
PV SYSTEM RATED AC OUTPUT CURRENT
PV SYSTEM RATED AC OUTPUT VOLTAGE
PV SYSTEM POWER PHASE
240V
SINGLE
32A
06/14/2023
WARNING
FUEL CELL POWER SYSTEM
CONTAINS ELECTRICAL ENERGY
STORAGE DEVICES
LABEL LOCATION:
AT THE LOCATION OF THE SERVICE
DISCONNECTING.
!
CAUTION: STORAGE SYSTEM
DISCONNECT
LABEL LOCATION:
AT THE LOCATION OF THE SERVICE
DISCONNECTING.
7
LABEL LOCATION:
MAIN SERVICE PANEL
IF MSD IS OUTSIDE PLACE IT THERE / IF
MSD IS INSIDE PLACE ON THE AC DISCONNECT.
8
41743 AVENTINE CT. PALM DESERT CA 92260
3
LABEL LOCATION:
SUB PANEL OR BACKUP LOADS PANEL, BATTERY,
INVERTER OUTPUT PANEL, MAIN SERVICE PANEL,
METER/MAIN, AND PV AC DISCONNECT
CAUTION-TRI POWER SOURCE
FIRST SOURCE IS UTILITY ELECTRICAL GRID
SECOND SOURCE IS AC BATTERY
THIRD SOURCE IS PV INVERTER
PV INVERTER
MAIN SERVICE DISCONNECT
BATTERY DISCONNECT
AC BATTERIES
ROOFTOP PV MODULES & TESLA MCI
FR
O
N
T
O
F
H
O
U
S
E
PW
PW
BL
P
GW
IN
V
MS
P
UM
GM
RD
S
JB
36
"
F
I
R
E
S
E
T
B
A
C
K
36
"
F
I
R
E
S
E
T
B
A
C
K
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36
"
F
I
R
E
S
E
T
B
A
C
K
36" FIRE SETBACK
36" FIRE SETBACK
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-6
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
SAFETY PLAN
SAFETY PLAN
INSTRUCTION:
1. USE SYMBOLS IN KEY TO MARK UP JOB SHEET
2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS
PART OF THE PRE-PLAN
3. DOCUMENT ALL ADDITIONAL HAZARD ON THIS PAGE AND
MAKE NOTES ON THE JCO SHEET
IN CASE OF EMERGENCY:
NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC:
NAME ________________________________________________
ADDRESS_____________________________________________
SAFETY COACH CONTACT INFORMATION
NAME ________________________________________________
PHONE_______________________________________________
ALL EMPLOYEES ON SITE SHALL BE MADE AWARE
OF HE SAFETY PLAN AND SIGN INDICATING THAT
THEY ARE AWARE OF THE HAZARDS ON-SITE AND
THE PLAN FOR WORKING SAFELY.
NAME SIGNATURE
MARK UP KEY
P
T
D
G
IL
AL
B
S
PERMANENT ANCHOR
TEMPORARY ANCHOR
DELINEATOR FOR MAPPING LINE
(LOW SLOPE ROOF RAIL ONLY)
GUARD RAIL STANCHON
(LOW SLOPE ROOF RAIL ONLY)
INSTALLER LADDER
AUDITOR LADDER
JUNCTION BOX
STUBOUT
SKYLIGHT
NO LADDER ACCESS (STEEP GRADE OR
GROUND LEVEL OBSTRUCTION)
RESTRICTED AREA
(EMPLOYEES ONLY)
CONDUIT
DATE:TIME:
SELECT ELECTRICAL TIE IN METHOD
MAIN/SUB BREAKER / TAP
GAS
H2O
7
Z
GAS SHUTOFF
WATER SHUTOFF
SERVICE DROP
POWER LINES
1 SAFETY PLAN
E-6 SCALE: 3/32" = 1'-0"
MOUNTING
PLANS
PERMANENT
ANCHORS
TEMPORARY
SPACING SPACING
MP1
TOTAL
AVENTINE CT.
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-7
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-8
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-9
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-10
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-11
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-12
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-13
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-14
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-15
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-16
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-17
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-18
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
EQUIPMENT
SPECIFICATION
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-19
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
ANCHORAGE
DETAIL
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-20
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
ANCHORAGE
DETAIL
SHEET NAME
SHEET SIZE
SHEET NUMBER
ANSI B
11" X 17"
PROJECT NAME & ADDRESS
E-21
41
7
4
3
AV
E
N
T
I
N
E
C
T
.
PA
L
M
D
E
S
E
R
T
,
CA
92
2
6
0
KA
C
I
E
G
O
E
T
T
S
C
H
R
E
S
I
D
E
N
C
E
DATE: 06/14/2023
REV BYDATEDESCRIPTION
REVISIONS
AP
N
:
62
2
0
5
1
0
6
3
PH
#
:
(7
0
2
)
4
3
9
-
2
9
5
9
EM
A
I
L
:
ka
c
i
e
g
o
e
t
t
s
c
h
@
y
a
h
o
o
.
c
o
m
CO
N
T
R
A
C
T
O
R
N
A
M
E
:
SW
E
L
L
S
E
R
V
I
C
E
S
I
N
C
.
DB
A
S
W
E
L
L
C
O
N
T
R
A
C
T
O
R
S
15
1
5
7
T
H
S
T
#
4
9
,
SA
N
T
A
M
O
N
I
C
A
,
C
A
,
9
0
4
0
1
PH
#
:
(
3
1
0
)
-
3
4
0
-
0
4
9
3
CS
L
B
L
I
C
.
#
1
0
2
1
1
8
3
AH
J
:
PA
L
M
D
E
S
E
R
T
C
I
T
Y
REV
ANCHORAGE
DETAIL