HomeMy WebLinkAboutPlans SOLAR SYSTEM SIZE: 12.150 kW DC SCOPE OF WORK: zn CEC AC SYSTEM SIZE: 10.950 kW AC Project consists of installing a solar photovoltaic (PV) system comprised of: BATTERY SYSTEM SIZE: 13.0 kWh (30) Q.Peak Duo BLK G10+ 405 modules (405 Watt) paired with Enphase IQ7HS Microinverters, CEC AC SYSTEM SIZE: 6.792 kW AC 13-1 SunVault Battery System, 60A disconnect, conduits w/fittings and wires, and a rack mounting system a' to provide a renewable power source for the customer. o NOTES: ; a 2) CU ' N� U 1. THIS SYSTEM IS GRID-INTERTIED VIA AC MODULES PER NEC 690.6. APPLICABLE CODES: > w SHEET INDEX N �, CALIFORNIA RESIDENTIAL CODE 2022 ; o o 10 a 2. THIS IS AN AC COUPLED STORAGE SYSTEM WITH BUILT-IN AC/DC CALIFORNIA BUILDING CODE 2022 GENERAL 0 �� E" INVERTER. CALIFORNIA FIRE CODE 2022 C1 COVER SHEET C L a o CALIFORNIA ENERGY CODE 2022 3. THIS IS A ROOF MOUNTED SYSTEM, ADDING 2.84 LB/SQ FT. CALIFORNIA GREEN CODE 2022 S1 SITE PLAN ROOF IS SPANISH CONCRETE TILE AT 19' PITCH. CALIFORNIA MECHANICAL CODE 2022 ELECTRICAL CALIFORNIA PLUMBING CODE 2022 E1 PROJECT SIGNAGE 4. THE SYSTEMS SQUARE FOOTAGE IS 624 FT (23% OF TOTAL ROOF AREA). CALIFORNIA ELECTRICAL CODE 2022 E2 SINGLE LINE MODULES HAVE AN AZIMUTH OF 180' &270'. CALIFORNIA AMENDMENTS 2022 NATIONAL ELECTRICAL CODE 2020 STRUCTURAL 5. MODULES ARE 0° TILT ABOVE ROOF SLOPE, NOT TO EXCEED 18"ABOVE CITY OF PALM DESERT MUNICIPAL CODE P1 PROFILE ELEVATIONS PV Instattation Company ROOF SURFACE. CONSTRUCTION HOURS: DATA SHEET Renova Energy Corp. OCTOBER 1 THRU APRIL 30 California-20f2 6. BUILDING IS A SINGLE STORY DWELLING. MODULE Monday - Friday 7:00 am - 5:30 pm SUNVAULT 7. LAG SCREWS ARE 5/16" X 4" AT 72" O.C. MAX, WITH 2.5" INTO FRAMING. Saturday OT AL AL0 am -LOWE WE D pm LOAD CALCULATION North American Board of Sunday NOT A t n nr- Government Code WIND CALCULATION ►r— 8. MODULES WILL BE SECURED TO ROOFTOP USING PEGASUS Holidays NOT ALLOWED RACKING ATTACHMENTS WITH INVISIMOUNT SUPPORT RAILS. AC DISCONNECT 9. ATTACHMENTS WILL BE FLASHED. MAY 1 THRU SEPTEMBER 30 Monday - Friday 6:00 am - 7:00 pm N 10. DESIGNED FOR BASIC WIND SPEED OF 130 MPH (WIND EXPOSURE C) PER Saturday 8:00 am - 5:00 pm N INVISIMOUNT CALCULATIONS, SEE SPECS. Sunday NOT ALLOWED �oQROFEJo�Nq� CN Government Code ��oy s��F�� LO 11. VISIBLE EXPOSED CONDUIT SHALL BE PAINTED TO MATCH. Holidays NOT ALLOWED W y (n Lli 12. MODULE DIMENSIONS ARE 41.1"X 74.0" PROJECT CONTACTS: N0. 16600 LU j CONTRACTOR: RENOVA * EXP. 6/30/24 * -)— Om 13. SYSTEM INSTALLATION SHALL BE PER NEC 690 & 702 AND IS SUBJECT TO permits@renovaenergy.com � F�ECTWC ���P U FIELD INSPECTION BY THE CITY. FOF CA,0 aj U PRIMARY CONTACT: N 14. PROPER CLEARANCES SHALL BE IN ACCORDANCE WITH CAL FIRE MATTHEW DE LA TORRE t LU 0� GUIDELINES. SECONDARY CONTACT: O N 00 W Andres Bautista-Aranda Z 2: C/) 15. ALL PV EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING LAB. Z J Q Lu 16. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. y Z • 2 4i' s z J _ ti J 17. WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY f� d INTERCONNECTIONS, BREAKER SHALL NOT READ LINE AND LOAD. a on A`� a Drawn By: 18. SMOKE DETECTOR AND CO DETECTOR SHALL BE REQUIRED. `� � � a'°°'°" �°'ne°sw�,p 0 � JACK GE i a nubmMrveD9i' • s� 4 r„ Date Drawn: Homewo b awn j� 10/20/2023 wo —n Qn ® Revision No. P.m s o pnn9a. 3 :-eit or certF� f 0 :r Sheet No. COVERr Plot Plan Vicinity Map Riverside County: APN 632600037 SHEET zn ASHBERRY COURT co o N M \ T L1J N \ > 0 C O \� — )7 F� Of Ulu m i m '�\ .� EXISTING METER#222011-905091 EXISTING 200 AMP MAIN SERVICE PANEL i 120/240 VOLT, 10, 3W ,fir LOCATED ON EAST EXTERIOR WALL m� 60 AMP LOCKABLE BLADE AC DISCONNECT _ SQUARE-D#DU222RB Pv Installation 120/240 VOLT Company \ LOCATED NEXT TO MAIN Renova Energy Corp. 200 AMP SUNPOWER SUNVAULT California-2012 HUB+ SV-HUB-01-B \ !O 120/240 VOLT LOCATED NEXT TO MAIN North American Board of STORAGE 13-1 SUNPOWER ENERGY NABCE� \ STORAGE SYSTEM #SPWR-M0011 I CHIMNEY 120/240 VOLT LOCATED INSIDE GARAGE HEAT DETECTOR I 1 \ 1 0 VOLT AC N \ LOCATED INSIDE GARAGE NEXT TO ESS QFtOFESS/ON N AC SOLAR MODULES \ �oy�E E JON/ CVq zz Z VENT I — — —— \ EXP. 6/30/24 * U O N O -ACCESS POINT i \� POOL \ FOFF CA,��F� U - CIRCUIT#1 �� \ W CO- CIRCUIT#2 I \'\ O "t 2 (w Ywc) w ❑ - CIRCUIT#3 \ Z —3 Q 0 I \ zu) M2 I z WUtiJ J I \,L- -- _ BACK YARD------------------ -- __ 2 _ PROPERTY LINE -- —-------------------------------------- Drawn By: JACK GER M/ Date Drawn: 10/20/2023 Revision No. N 0 Sheet No. W E S1 S SITE PLAN SCALE: 1" = 15' SUNVAULT HUB + 60A AC DISCONNECT zn SAFEGUARDS WARNING WARNING 1. SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL. ALL WIRING BETWEEN AC MODULES SHALL BE co ELECTRIC SHOCK HAZARD. DO NOT ELECTRIC SHOCK HAZARD. DO NOT ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE-D & GE. PV-WIRE AND AC CABLE. Q, Q' : o TOUCH TERMINALS. TERMINALS ON TOUCH TERMINALS. TERMINALS ON Q BOTH THE LINE AND LOAD SIDES MAY BOTH THE LINE AND LOAD SIDES MAY 2. ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED. ALL CONDUIT SHALL BE 3/4" EMT OR LARGER. b. o � co 4t BE ENERGIZED IN THE OPEN POSITION. BE ENERGIZED IN THE OPEN POSITION. 3. WILEY CABLE CLIPS SHALL BE USED. ALL CONDUIT SHALL BE BONDED. "m Q v '. 4. ALL EMT SHALL USE OUTDOOR RAINTIGHT COMPRESSION FITTINGS. " E't,C)� � ENERGY BREAKER MAX AC OPERATING CURRENT: 28.3 A ALL CONDUIT SHALL BE SUPPORTED BY RUBBER ru 53.2 _ , 00 OPERATING AC VOLTAGE: 240 Volts 5. ALL EQUIPMENT SHALL BE LABELED. w 6 �L N WARNING 6. ADD COMBINER/JUNCTION BOXES AS NEEDED. PYRAMID SUPPORTS. o o o 7. AN INTERNAL BLOCKING DIODE IS PROVIDED IN EACH MODULE. STEEL CITY 6"X6"X4" (OR LARGER) OUTDOOR �� E" L INVERTER OUTPUT CONNECTION DO MAIN BREAKER 8. MODULE GROUNDING SHALL BE MADE VIA RACKING CLAMPS. C Lo o NOT RELOCATE THIS OVER CURRENT JUNCTION BOXES SHALL BE USED AS NEEDED. DEVICE. RAPID SHUTDOWN DISCONNECT 1 OF 2 9. ALL NEUTRAL TO GROUND CONNECTIONS SHALL OCCUR IN THE MAIN ALL CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF MAIN PANEL PANEL. CONNECTORS TO PROTECT WIRES. BATTERY AC DISCONNECT 10. EMT SHALL BE 3/4" MINIMUM. THIS PANEL IS FED BY THREE SOURCES: RAPID SHUTDOWN DISCONNECT 2 OF 2 11. JUNCTION BOX/COMBINER BOX ENTRY SHALL USE COMPRESSION UTILITY, BATTERY&SOLAR PHOTOVOLTAIC FITTINGS. MAIN PANEL SUNVAULT PHOTOVOLTAIC SYSTEM EQUIPPED ENERGY STORAGE MARKING PVCompalnyon WITH RAPID SHUTDOWN SYSTEM DISCONNECT 1. THE MATERIAL USED FOR MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE Renova Energy Corp. TURN RAPID SHUTDOWN ENVIRONMENT. MARKING AS REQUIRED IN SECTIONS R 331.2.2 THROUGH R331.2.4 SHALL HAVE LETTERS California—2012 SWTCH TO THE FI"O POSITION TO NOMINAL ESS AC VOLTAGE: 240 V CAPITALIZED WITH A MINIMUM HEIGHT OF 3/8" WHITE ON RED BACKGROUND. (CRC R331.2.1) SHUT DOWN PVSYSTEM AND REDUCE MAXIMUM ESS DC VOLTAGE: 51.2 V 2. THE MARKING CONTENT SHALL CONTAIN THE WORDS "WARNING; PHOTOVOLTAIC POWER SOURCE" (CRC R331.2.2) SHOCK HAZARD IN THE ARRAY North American Board of NOTES ^ .-.�o 1. WIRE AND SIZES ARE AS INDICATED OR LARGER. 2. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. 3. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE#8 AWG COPPER GROUND WIRE AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. QROFESS/O 4. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. N O EI- JON 9( PANEL: SUNVAULT HUB+ PANEL VOLTAGE: 240/120 V 10,3W CIRCUIT CODE: N: NON-CONTINUOUS N d m LOCATION: NEXT TO MAIN BUS: 200A L: LONG-CONTINUOUS CD � NO.6600 M MOUNTING: SURFACE R: DEMANDABLE RECEPTACLES (n EXP. 6/30/24 Lu Lu � * * VA LOAD LOAD o TYPE C.B. BUS C.B. TYPE o LOAD VA LOAD Lu N MAIN PANEL: ATTACHED TO MAIN PANEL COVER 'p"�9� �ZfCTR��P���\P q g DESCRIPTION N R L TR P A B P TR L R N 0U DESCRIPTION A B 0 0 WARNING ® FOF CAS 1920 CIRCUIT 1 L 20 20 2 x U Q THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC 1920 CIRCUIT 1 L - - - x Oj C) GENERATOR LOCATED ON THE ROOF AS SHOWN. 1920 CIRCUIT 2 L 20 20 2 x N THE SYSTEM MAY BE DISCONNECTED FROM THE Lu � FACILITY PER THE AC DISCONNECT AS SHOWN. 1920 CIRCUIT 2 L - - - x 0 N Co Lu MAIN PANEL 1920 CIRCUIT 3 L 20 20 2 x Z 2 C) (YOU ARE HERE) 1920 CIRCUIT 3 L - - - x z J Q PV RAPID SHUTDOWN (BREAKER INSIDE E z MAIN) z_ J U ti J BATTERY 3396 STORAGE 13-1 L 40 40 2 x o `� 0 r RAPID SHUTDOWN 3396 STORAGE 13-1 L - - - x L (NEXT TO MAIN) 9156 9156 PHASE TOTAL Drawn By: ENERGY STORAGE PHASE TOTALS A+B CONNECTED VA(CODE L): 18312 JACK GER WIM/ SYSTEM CONNECTED VA(CODE R): GARAGE Date Drawn: (GARAGE) CONNECTED VA(CODE N): 10/20/2023 TOTAL CONNECTED KVA: 18.3 N TOTAL PANEL AMPS: 76.3 Revision No. W_*_E 0 S Sheet No. NOTE: RED BACKGROUND WITH WHITE E1 LETTERING 3/8" LETTER HEIGHT PROJECT PROJECT SIGNAGE NOTES & PANEL SCHEDULE SIGNAGE SOLAR SYSTEM SIZE: 12.150 kW DC SOLAR BREAKER SUITABLE ZT11 CEC AC SYSTEM SIZE: 10.950 kW AC FOR DISCONNECTING MEANS V' PER NEC 690.13 BATTERY SYSTEM SIZE: 13.0 kWh RELOCATE LOADS TO CEC AC SYSTEM SIZE: 6.792 kW AC 200 AMP SUNPOWER SUNVAULT c: a N HUB+SV-HUB-01-B EXISTING 200 AMP MAIN SERVICE PANEL C ° a`6i rn�2 *k 120/240 VOLT LOCATED NEXT TO MAIN 240/120 VOLT, 2-POLE 3 LOCATED ON EXTERIOR WALL �o a) TO UTILITY fu - STORAGE 13-1 SUNPOWER ENERGY \\ w STORAGE SYSTEM#SPWR-M0011, / cog a) 120/240 VOLT 3 M M TER#222011-905091 b 0 E v LOCATED ON EXTERIOR WALL 40A 10 1: ° m ° c� EXISTING 200A a o MAN BREAKER a) 0 60 AMP LOCKABLE BLADE LOADS AC DISCONNECT SQUARE-D#DU222RB LOADS 0/--"10- SOLAR ARRAY 120/240 VOLT 100 AMP (30)SUNPOWER 405 WATT LOCATED NEXT TO MAIN LOADS n BACKUP 200A BUS C BREAKER PHOTOVOLTAIC MODULES Adw #Q.Peak Duo BLK G10+ 405 W/ Enphase IQ7HS Microinverters T 20A/1 • s (3 CIRCUITS OF 10 MODULES) J BOX T 20A/1 PV Installation E20A/1 GE NERATION 125A BUS Company I-G R Renova Energy Corp. California-2012 15A/1 R PVS6 North American Board of 7 20A N N-BACKUP 125A BUS EXISTING GROUNDING ELECTRODE CONDUIT SCHEDULE .-. AFCI PROTECTION IS REQUIRED WHEN LOADS ARE LOCATION CONDUCTORS CONDUIT N RELOCATED MORE THAN 6' [210.12(D)]. 1 (6)#12 ENPHASE CABLE,(1)#6 BARE COPPER N/A N PCS OF THE SUNVAULT HUB+WILL LIMIT THE 2 (6)#10 THWN-2,(1)#8 EGC 3/4"EMT N AMOUNT OF BACKFEED CURRENT TO THE MAINIt 'FOR UTILITY PURPOSES ONLY:(30)ENPHASE IQ7HS-66-ACM-US 240V[S111 INVERTERS SERVICE PANEL. SETTING MUST NOT BE 3 (3)#8 THWN-2,(3)#12 THWN-2,(1)#10 EGC 2"EMT LLO EGC=EQUIPMENT GROUNDING CONDUCTOR,GEC=GROUNDING ELECTRODE CONDUCTOR ACCESSIBLE TO NON-AUTHORIZED INDIVIDUALS. 4 (3)#2 THWN-2, 1 #8 EGC 1-1/4"EMT U) #6 COPPER SOLID GROUND TO BE USED ON ROOFTOP WHEN NOT PROTECTED BY CONDUIT ( ) ALL BREAKERS SHALL BE 2 POLE UNLESS OTHERWISE NOTED U) ALL INNER-CIRCUIT WIRING SHALL BE#10 THWN-2 WIRE OR GREATER LU � N SINGLE LINE DIAGRAM - O m AC CIRCUITS SUNVAULT HUB +TO MAIN PANEL ^>- Q U STORAGE TO SUNVAULT HUB + MAX OUTPUT= (30 MODS X 1.60 AMP + 28.3 AMPS)X 1.25 [PER NEC 215.2 (A)(1)] = 95.4 AMPS (100A BREAKER) or) STORAGE 13-1 = 28.3 AMPS X 1.25 [PER NEC 215.2 (A)1] = 35.4 AMP (40 AMP STORAGE BREAKER) AC CONDUIT SHALL BE MOUNTED ON EXTERIOR WALL. W MAX VOLTAGE AC 240 VOLT. #2 WIRE = 130 AMPS X .82[PER NEC TABLE 310.16 & PER NEC TABLE 690.31(A)(a)] = 106.6 AMP >_ 100 AMP ✓ O N 00 LU AC CONDUIT SHALL BE MOUNTEDON EXTERIOR WALL. (3)#2 THWN-2 AWG WIRE, (1)#8 THWN-2 GROUND Y "t � W #8 WIRE = 55 AMPS X .82[PER NEC TABLE 310.16 & PER NEC TABLE 690.31(A)(a)] =45.1 AMP >_40 AMP 1-1/4" EMT @ 40% FILL PER NEC TABLE C.1 = (5)#2 THWN-2 WIRES ✓ z J Q Q (3)#8 THWN-2 AWG WIRE, (1)#10 THWN-2 GROUND E zU) N2 co 2" EMT @ 40% FILL PER NEC TABLE C.1 = (36)#8 THWN-2 WIRES MAIN PANEL BACKFEED CALCULATION z J U [` J EXISTING 200 AMP MAIN SERVICE PANEL o AC MODULES TO SUNVAULT HUB+ EXISTING 200 AMP MAIN BREAKER 0- 3 CIRCUITS X 10 MODULES = 30 MODULES PCS TO BE IN ACCORDANCE WITH NEC 705.13. Drawn By: MAX VOLTAGE AC 240 VOLT PCS TO MONITOR SERVICE CONDUCTORS. JACK GERO M/ 1.60 AMPS EACH CIRCUIT X MAX 10 MODULES X 1.25[PER NEC 690.8] = 20.0 AMPS (20 AMP CB) PCS CONTROLLED CURRENT PLUS UTILITY CURRENT SHALL NOT EXCEED AMPACITY OF BUSBAR. Date Drawn: AC CONDUIT SHALL BE MOUNTED A MINIMUM OF 1"ABOVE ROOFTOP SURFACE. OFESS/ QR ON 10/20/2023 ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR &42°C AMBIENT TEMP. PER SOLARABCS.ORG c�Oy�E E JOAI #10 WIRE =40 AMPS X .82[PER NEC TABLE 310.16 & PER NEC TABLE 690.31(A)(a)] = 32.8 AMPS � �2� � 'G� Revision No. 32.8 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(3)] = 26.24 AMPS >_ 20 AMPS ✓ ,�.�,� / rrri 3 CIRCUITS = (6)#10 THWN-2 AWG WIRE, (1)#10 THWN-2 GROUND or_ NO. 16660 0 3/4" EMT @ 40% FILL PER NEC TABLE C.1 = (10)#10 THWN-2 WIRES ✓ EXP. 6/30/24* Sheet No. �ECTR\CP� OF-CA1-\FO� E2 SINGLE LINE CALCULATIONS TOP VIEW ELEVATION A-A' Vernrn'• /`■ N M fl C N 2) • m c 'V L1JC . J N > � O o °c oo E v C A LO n' d o W U c0 PV Installation *MODULES NOT TO EXCEED 18"ABOVE ROOF SURFACE Company A A' I SCALE: Renova Energy Corp. 2 1"=4' California-2012 ELEVATION B-B' North American Board of N1A9CEP N N N c ~ U O a) *MODULES NOT TO EXCEED 18"ABOVE ROOF SURFACE U SCALE: 3 N - USE (2) 5/16" x 4" SS LAG SCREWS AT 6' O.C. WITH 2.5" 1 _4 O N (Lu OnoW EMBEDMENT INTO WOOD RAFTERS. ATTACHMENT DETAIL - RAFTERS ARE 2"x6"AT 2' O.C. Y w Q Q - DO NOT INSTALL STANDOFFS OVER WOOD CRICKETS z J - STANDOFFS ATTACHED TO MAIN ROOF FRAMING. z HORIZONTAL DISTANCE BETWEEN ATTACHMENTS z W U J NOT TO EXCEED 6 FEET ON CENTER a) J ~ Q VERTICAL DISTANCE BETWEEN ATTACHMENTS L-BRACKET PV MODULE 0- NOT TO EXCEED 4 FEET ON CENTER CLAMP Drawn By: /_ RAIIL JACK GERO M Date Drawn: 3/8"X 3/4"SS HEX BOLT 10/20/2023 3/8"NUT Revision No. 3/8"X 3/4"SS HEX BOLT N 0 W E Sheet No. S P1 *MODULES NOT TO EXCEED 18"ABOVE ROOF SURFACE *MODULES NOT TO EXCEED 18"ABOVE ROOF SURFACE PROFILE SCALE:1 1 SCALE: ^ ELEVATIONS 1"=12' N/A �F renova.energy SINGLE-FAMILY DWELLING-LOAD CALCULATION NEC 2020 Edition: Following Example Annex D2(b) Hub+ backup loads 1. OTHER LOADS: a. General lighting& receptacle loads; 500 sq.ft.x 3 VA= 1,500 VA b. Small appliance loads; 1,500 VA x 1 circuits= 1,500 VA c. Laundry= 0 VA d. Special loads: Dishwasher = 0 VA Disposal = 0 VA Refrigerator = 1,440 VA Water heater( if Gas=0) = 0 VA Oven-220.55 = 0 VA Cook Top = 0 VA EV car charger-future = 0 VA Jacuzzi tub = 0 VA Pool = 0 VA Garage/outside plugs = 1,440 VA Clothes Dryer = 0 VA Microwave = 1,800 VA (Subtotal) 7,680 VA First 10,000VA x 100%= 7,680 VA Remaining 0 VA x 40% 0 VA (Total#1 = Net Load) 7,680 VA 2. HEATING OR A/C LOAD: Heating units (3 or less) = VA x 65% 0 VA Heating units (4 or more) = VA x 40% VA A/C unit#16069= 0 VA x 100% 0 VA Gar. Swamp Clr= 0 VA x 100% 0 VA (Total#2 = Net Load) 0 VA Net Load (Total#1+Total#2 =Subtotal Net Load) 7,680 VA VA SERVICE: I = V SERVICE: I= 7,680 VA = 32.0 A 240 V Service amperes required 32.0 A Service amperes provided 100 A powered by Quality � � . • : , � Controlled PV • � , TUVRheinla d • w 'tuv.com ID 1111232615 �q TOP BRAND PV / ASSEMB- EUROPE USA Warranty 2021 0 CELLS Product a Performance Yield Security BREAKING THE 20%EFFICIENCY BARRIER nnn/III Illlllnlllllll IIII Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PW of v� the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields,whatever the weather with excellent low-light and temperature behavior. _ ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology,Anti PID ` Technology',Hot-Spot Protect and Traceable Quality Tra.QTM^ EXTREME WEATHER RATING High-tech aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year 1 linear performance warranty2. 6 BUSBAR 12 BUSBAR APT test conditions according to IEC/TS 62804-1:2015,method A(-1500V,96h) cFi i TFCNNOLOGY CELLTECHNOLOGY 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany Q CELLS MECHANICAL SPECIFICATION Format 74.0in x 41.1in x 1.26in(including frame) (1879mm x 1045mm x 32mm) 74.0"(1879 mm) 42.8"(1088 mm) 15.6-(395.5 mm) Weight 48.51bs(22.Okg) Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with za9.2(26Dmm) _ anti-reflection technology 1 1 4 x Grounding P°iMa 4 0.18-(4.5 mm) Freme Back Cover Composite film 39.2(996 mm) Frame Black anodized aluminum Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes ebB1� =a92••(zsomm) Cable 4mm2 Solar cable;(+)>49.2in(1250mm),(-)>_49.2in(1250mm) 8a Dm10eg°ho1es 4.M ounting slots(DETAIL A) _ Connector Staubli MC4;IP68 I I 1 +I 1.26•'(32 mm) DETAILA 0.63"(16 mm) 0.96••(24.5mm)IyI0.33"(8.6 mm) ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC1(POWER TOLERANCE+5 W/-0 W) Power at MPP1 PMPP [W] 385 390 395 400 405 Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 E Open Circuit Voltage' Voc IV] 45.19 45.23 45.27 45.30 45.34 5 Current at MPP IMPP [A] 10.59 10.65 10.71 10.77 10.83 Voltage at MPP VMPP IV] 36.36 36.62 36.88 37.13 37.39 Efficiency' rl [%] >_19.6 >_19.9 >_20.1 >_20.4 >_20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT2 Power at MPP PMPP [W] 288.8 292.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage Voc IV] 42.62 42.65 42.69 42.72 42.76 'c 2 Current at MPP IMPP [A] 8.35 8.41 8.46 8.51 8.57 Voltage at MPP VMPP IV] 34.59 34.81 35.03 35.25 35.46 1Measurement tolerances PMPP 3%;Isc;Voc 5%at STC:1000 W/m2,25 2°C,AM 1.5 according to IEC 60904-3.2800 W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ••100 cE11s K ssA , o>? At least 98%of nominal power during I I I I w �a w.++a°aard m,r�ar�a„�M�er a w a first year.Thereafter max.0.5% W I I I I I degradation per year.At least 93.5% u 100 - ----I---- - of nominal power up to 10 years.At a z least 86%of nominal power up to w z ti of so 60 _ ___ wo 25 years. T____I_ T __I_ .Zo All data within measurement toleranc- 'c° ' es.Full warranties in accordance with 80 0 Q 200 400 600 800 low N the warranty terms of the Q CELLS o o B0 sales organisation of your respective RRADIANCE[W/m'] a o s 10 15 20 country.1°f°r1na YEARS Typical module performance under low irradiance conditions in o 16pa��°a wain inananaar ar°°uion�pacro in solo cease sapramear 2m4) a comparison to STC conditions(25°C,1000 W/m2) m M TEMPERATURE COEFFICIENTS o Temperature Coefficient of Ise a [%/K] +0.04 Temperature Coefficient of VGo (i [%/K] -0.27 Temperature Coefficient of PMPP y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109 5.4(43 3°C) m 0 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vsrs IV] 1000(IEC)/1000(UL) PV module classification Class II o 6I Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 W Max.Design Load,Push/Pull3 [Ibs/ft2] 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°Fupto+185°F c Max.Test Load,Push/PUIl3 [Ibs/ft2] 113(5400 Pa)/84(4000 Pa) on Continuous Duty (-40°Cupto+85°C) o 3See Installation Manual U QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION p "tl� )b o UL 61730,CE-compliant, liant, 53'n a, Quality Controlled PV-TUV Rheinland, OC--O-J I40;MCI O p � IEC 6atent o16,IEC,215(s2016, ��® ♦ ♦ ® o U.S.Patent No.9,893,215(solar cells), (` (`� Tw6namland Horizontal 76.4in 43.3in 48.Oin 1656bs 24 24 32 C certTtladUS packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules w UL61730 ID 111t133o TT .D n Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha a CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiryQus.q-cells.com I WEB www.q-cells.us Data Sheet IQ7HS Microinverter Enphase Microinverter Region:AMERICAS INPUT DATA(DC) IQ7HS-66-M-US Commonly used module pairings' 320W-460W Module compatibility2 66 cell/120 half-cell/132 half-cell Maximum input DC voltage 59V Peak power tracking voltage 38V-43V Operating range 20V-59V Min/Max start voltage 30W59V Max DC short circuit current(module Isc) 15A IQ7HS Microinverter The high-powered smart grid-readylQ7HS Overvoltage class DC port II DC port backfeed current OA Microinverter with integrated MC4 connectors PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; dramatically simplifies the installation process while AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @240 VAC @208 VAC achieving the highest system efficiency. Peak output power 384 VA 369 VA Maximum continuous output power 384 VA 369 VA Nominal(L-L)voltage/range3 240W211-264V 208V/183-229V Maximum continuous output current 1.60A(240V) 1.77A(208V) The IQ Series Microinverters extend the reliability Nominal frequency 60 Hz 60 Hz standards set forth by previous generations and Extended frequency range 47 Hz to 68 Hz 47 Hz to 68 Hz AC short circuit fault current over 3 cycles 4.82A 4.82 A undergo over a million hours of power-on testing, Maximum units per 20 A(L-L)branch circuit4 10 9 enabling Enphase to provide an industry-leading Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA warranty of up to 25 years. Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240V @208V CEC weighted efficiency 97.0% 96.5% MECHANICAL DATA Ambient temperature range -40°C to+60°C Relative humidity range 4%to 100%(condensing) Connector type Staubli made MC4 Easy to Install Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) • Lightweight and simple Cooling Natural convection-No fans • Faster installation with improved,lighter two-wire cabling Approved for wet locations Yes • Built-in rapid shutdown compliant(NEC 2014,2017& Pollution degree PD3 2020) Enclosure Class II,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA type 6/outdoor Efficient and Reliable Altitude 2000 m FEATURES • Highest CEC efficiency of 97.0°i° Communication Power Line Communication(PLC) • More than a million hours of power-on testing Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break LO disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. -3 ENPHASEm Class II double-insulated enclosure IQ7HS _ Compliance CA Rule 21 (UL1741-SA),IEEE 1547:2018(UL1741-SB), UL listed UL 62109-1,FCC Part 15 Class B,HECO v1.1,ICES-0003 Class B, CAN/CSA-C22.2 No.107.1-01 This product is UL listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, o,� Smart Grid-Ready NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. Ammi • Complies with advanced grid support,voltage and frequency ride-through requirements 1.No enforced DC/AC ratio.See the compatibility calculator at https:Henphase.com/en-us/support/module-compatibility. 2.Provided the module is compatible with all other parameters in the datasheet. • Remotely updates and responds to changing 3.Nominal voltage range can be extended beyond nominal if required by the utility. grid-requirements 4.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. • Configurable for varying grid profiles • Meets CA Rule 21 (UL1741-SA)and IEEE 1547:2018 (U L1741-S B) To learn more about Enphase offerings,visit enphase.com E N P H A S E ©2022 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. E N P H A S E To learn more about Enphase offerings,visit enphase.com `/ 12-15-2022 SUNP WER" Technical Notification Title SunVaultT"' Completion of Large-Scale Fire Testing (UL 9540A), 540838 RevA Date July 06, 2021 Authors Craig Walker, Principal Battery Engineer Application SunVaultT"' systems 1.0 Overview SunPower°SunVaultTm energy storage system (ESS) units have completed large-scale fire testing as per UL 9540A Edition 4 2019.The testing results qualify SunVault ESS units for exceptions from certain installation requirements in fire code compliance beginning July 1, 2021 in California and in other jurisdictions.This Tech Note explains the SunVault ESS energy ratings, provides the test background information, and references fire code requirements where these UL 9540A test results should be considered for an exemption or an exception. 2.0 SunVault ESS and Aggregate Energy Ratings SunVault Model Number Description Rated Energy SV-BASE13-12-A Base ESS unit 13 kWh SV-ENERGY13-12-A Energy expansion ESS unit 13 kWh 2.1 Base and Fnergy Expansion '­lste— The base SunPower SunVault installation consists of one SV-BASE13-12-A ESS unit rated at 13 kWh (paired with one SunVault Hub+).Additional 13 kWh ESS units (SV-ENERGY13-12-A) can be added to increase the aggregate energy of the SunVault installation in 13 kWh increments. For example, a SunVault installation that combines the 13 kWh SV- BASE13-12-A ESS unit with a 13 kWh SV-ENERGY13-12-A ESS energy expansion unit would have an aggregate energy rating of 26 kWh. SunPower Corporation proprietary information.This document is electronically controlled.The latest revision Title:Tech Note-SunVault-Completion of Large-Scale Fire Testing(UL 9540A), is available in the document management system.All printed copies are not controlled and may be outdated 540838 RevA unless marked with a red ink"Controlled Copy'stamp. Date:07/06/2021 Page 1 of 4 Form:001-51499 Rev I SUNP WERO Technical Notification Ina given installation, combining 13 kWh SV-BASE13-12-A ESS units with 13 kWh SV-ENERGY13-12-A units provides the ability to expand both the power and the energy of that particular system. Where the local fire code prescribes a maximum energy rating requirement for individual ESS units and for aggregate energy in a specific indoor or outdoor installation location,the SunVault individual ESS rating is 13 kWh and the aggregate energy rating is a multiple of 13 kWh which expands incrementally depending on the quantity of ESS units in the system, and does not exceed 104 kWh. 3.0 SunVault UL 9540A Standard Compliance The large-scale fire testing was conducted and reported by UL in accordance with UL 9540A Edition 4 2019, at their fire testing laboratory in Northbrook, IL. The testing and reporting were completed under UL Project#4789520191.8 (see Section 4.6 of this Tech Note). UL designed the test setup and data collection so that the results could be judged against the UL 9540A unit-level performance criteria for both indoor and outdoor wall-mounted residential ESS units. The SunVault test setup comprised three individual ESS units which represented all SunVault ESS models and which were wall mounted with 6" (152 mm) separation distance between each unit.The center unit contained a battery module with heaters installed on a centrally located cell. This cell was externally heated at a rate of 4-7°C/minute until the cell exhibited a condition called thermal runaway. The test instrumentation recorded the effects of the resulting thermal event in accordance with UL 9540A data collection requirements. Note: UL 9540A test setup requirements prevented testing both wall-mounted and floor-mounted systems in a single test.Wall-mounted systems are considered to be worst case with respect to complying with the UL 9540A performance criteria, and for this reason we believe the test results from the report can be applied to floor- mounted ESS units as well. 4.0 Application to Fire Code Requirements SunVault systems must be installed according to applicable sections of the effective local fire code. Fire codes and fire code sections referenced in this document are intended to inform about requirements which may be excepted or addressed by the large-scale fire testing results. The inclusion of fire codes or fire code sections in this Tech Note does not necessarily imply applicability to all or to any SunVault installations. 4.1 ESS Spacing Exceptions UL determined that a thermal event initiated in one SunVault ESS unit did not propagate to the adjacent ESS units when the units were installed with 6" (152 mm) of separation on either side of the initiating ESS unit(see pg. 4 of the report). The initiated thermal event was contained within the initiating battery module inside the initiating ESS unit, and no flaming was observed during the test(pg.4). These results qualify SunVault ESS units for exception from the prescribed 36" (914 mm) ESS spacing requirements that are part of many local fire codes.The exception permits SunVault installation with 6" (152 mm) minimum separation distance between ESS units. Code references: • NFPA 1 (2018) 52.3.2.3.5 • NFPA 855 (2020) 15.5, 4.1.5 • IFC(2018)1206.2.8.3 • I FC(2021) 1207.11.2.1 • CFC Quly 2021 Supplement) 1206.11.2.1, 1206.1.5 Sun Power Corporation proprietary information.This document is electronically controlled.The latest revision Title:Tech Note-SunVault-Completion of Large-Scale Fire Testing(UL 9540A), is available in the document management system.All printed copies are not controlled and may be outdated 540838 RevA unless marked with a red ink"Controlled Copy`stamp. Date:07/06/2021 Page 2 of 4 Form:001-51499 Rev I SUN P %.. WERO Technical Notification 4.2 Non-Combustible Construction UL determined that SunVault complies with the UL 9540A performance criterion for installation in locations with combustible constructions (pg. 5). This performance criterion requires that wall surface temperatures do not rise to greater than 970C(174.6°F) above ambient.The maximum wall surface temperature rise achieved during SunVault UL 9540A testing was just 540C(97.20F) above ambient(pg. 22).The test result was achieved with the ESS units installed on black-painted plywood which is combustible and can exhibit a faster temperature rise when compared to gypsum. Consider SunVault's compliance with the UL 9540A performance criterion for installation on combustible construction when evaluation construction requirements for ESS installation areas. Code references: • NFPA 855 (2020) 15.6.1(1) • CFC(July 2021 Supplement) 1206.11.3.4 4.3 Separation from Doors, Windows, and Means of Egress for Outdoor Installations The UL 9540A testing shows that a thermal event involving the system will not adversely impact occupant egress paths from doors or windows which are located at least 6"from the edges of an ESS unit. Wall temperature was measured at 6" intervals along a vertical line offset 6"from the edge of the initiating ESS unit. The maximum temperature measured at each interval along this line was 10°C(180F) above ambient(pg. 22).The maximum surface temperature of an adjacent ESS unit located 6"from the initiating ESS unit was 9°C(16.2°F) above ambient(pg. 22). Additionally, no flaming or explosion hazards were observed. These observations show that occupant egress would not be affected from doors or windows located 6" (152 mm)from the edge of an ESS. Code references: • NFPA 1 (2018) 52.3.2.1.4.5.2 • NFPA 855 (2020) 15.6.1(3) • I FC(2021) 1207.11.3.3 • I FC(2018) 1206.2.8.7.2 • CFC Quly 2021 amendment) 1206.11.3(3) 4-4 Fire SupprPcsinn SunVault achieved the UL 9540A unit-level performance criteria for indoor wall-mounted ESS systems without the use of fire suppression. No flaming or explosion hazards were observed during the test. Automatic sprinkler systems or other methods of automatic fire suppression are not required for SunVault to comply with the UL 9540A unit-level performance criteria. Code reference: • NFPA 1 (2018) 52.3.2.7 4.5 Ventilation ana Minimum Room Size SunVault ESS feature batteries of the lithium-ion variety and which do not produce flammable or toxic gas during charging, discharging, or normal use conditions. Lithium-ion batteries are not required to comply with ventilation or minimum room size requirements in the fire codes. Ventilation and minimum room size requirements in the fire codes do not apply to SunVault ESS. Sun Power Corporation proprietary information.This document is electronically controlled.The latest revision Title:Tech Note-SunVault-Completion of Large-Scale Fire Testing(UL 9540A), is available in the document management system.All printed copies are not controlled and may be outdated 540838 RevA unless marked with a red ink"Controlled Copy'stamp. Date:07/06/2021 Page 3 of 4 Form:001-51499 Rev I SUNP WERO Technical Notification Code references: • NFPA 1 (2018) 52.3.2.8, 52.3.2.11 • N FPA 855 (2020) 15.11, 15.12 • I FC(2021) 1207.6 • I FC(2018) 1206.2.11.3, 1206.2.12 • CFC Quly 2021 Supplement) 1206.11.8, 1206.11.9 Note:Always install SunVault systems according to the effective local fire code. Fire codes referenced in this Tech Note are provided to inform about requirements which may be excepted or addressed by the large-scale fire testing results. Inclusion of fire codes in this document does not necessarily imply applicability to all or to any SunVault installations. 4.6 UL 9540A Test Report Cover Page UL 9540A Report EdA Unit Report 2020-04-21 U� UNIT TEST REPORT UL 9540A Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems(AACD) Project Number...............................: 4789520191.8 Date of issue...................................: 06/072021 Total number of pages...................: 66 UL Report Office...................._......: UL LLC.Northbrook,IL,60062 USA Applicant's name............................: Sunpower Corp Address...........................................: 51 Rio Robles San Jose,CA,95134,USA Test specification: 4",Edition,Section 9,November 12,2019 Standard..........................................: UL 9540A, Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems Test procedure...............................: 9.1—9.8 Non-standard test method ...........: N/A Copyright©2020 UL LLC All Rights Reserved. General disclaimer: The test results presented in this report relate only to the sample tested in the test configuration noted on the list of the attachments. UL LLC did not select the sample(s),determine whether the sample(s)was representative of production samples,witness the production of the test sample(s),nor were we provided with information relative to the formulation or identification of component materials used in the test sample(s). The issuance of this report in no way implies Listing,Classification or Recognition by UL and does not authorize the use of UL Listing,Classification or Recognition Marks or any other reference to UL on the product or system. UL LLC authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. UL's name or marks cannot be used in any packaging,advertising,promotion or marketing relating to the data in this Report,without UL's prior written permission. UL LLC,its employees,and its agents shall not be responsible to anyone for the use or non-use of the information contained in this Report,and shall not incur any obligation or liability for damages,including consequential damages,arising out of or in connection with the use of,or inability to use,the information contained in this Report. If you have any questions or would like to request additional information please contact SunPower regulatory compliance engineer Mark McMurtrey at mark.mcmurtrey@sunpowercorp.com. Thank you for helping us change the way our world is powered. SunPower Corporation proprietary information.This document is electronically controlled.The latest revision Title:Tech Note-SunVault-Completion of Large-Scale Fire Testing(UL 9540A), is available in the document management system.All printed copies are not controlled and may be outdated 540838 RevA unless marked with a red ink"Controlled Copy'stamp. Date:07/06/2021 Page 4 of 4 Form:001-51499 Rev I Lntertek Total Quality.Assured. Verification of Conformity Verification Number: 104395807CRT-001-VOC On the basis of the tests undertaken,the sample of the below product have been found to comply with the requirements of the referenced standards at the time the tests were carried out.This verification is part of the full test report and should be read in conjunction with it. Applicant Name&Address: I SunPower Corporation 1414 Harbour Way South Suite 1901 Richmond, CA 94804-3694 USA Product Description: Panelboard Ratings&Principle Characteristics: See Amendment 1 Models/Type References: SV-HUB-01-C,SV-HUB-01-B (It is paired with SunPower ESS(SV-BASE13-12-A OR SV-BASE13-12-B OR EQS- BASE13-11-A, Optional:SV-Energyl3-12-A,SV-Energy13-12-B) Brand Names: SUNPOWER Specification<s>/Standards: Inverters, Converters,Controllers And Interconnection System Equipment For Use With Distributed Energy Resources [UL 1741:2010 Ed.2(Supplement A)+ R:15Feb2018] Power Control Systems (PCS) Certification Requirement Decision 3/8/2019 Verification Issuing Office Name& Intertek Testing Services NA, Inc., Address: 3933 US Route 11,Cortland, NY 13045 USA Date of Tests: 2/1/2022 to 2/10/2022,4/21/2022 to 5/10/2022 Test Report Number(s): 104106139CRT-001 Signature Name: Dishant Patel Position: Project Engineer Date: 8 March 2022 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected.This Verification by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Intertek Page 1 of 5 GFT-OP-11a(22-August-2019) Lntertek Total Quality.Assured. Amendment 1 ❖ Hub+Nameplate For Model#SV-HUB-01-C SUNPOWER Hub+TM Designed and manufactured in the USA. S U N P W E R MODEL NUMBER:SV-HUB-01C Indoor/Outdoor(Type 3R) SERIAL NUMBER Suitable for use as service equipment when equipped with a main overcurrent device, installed only per applicable code and manufacturer recommendations,in a vertical orientation. Suitable for use with interconnected parallel electric power production sources. PANEL TYPE PHASE SINGLE PHASE,3 WIRE PANEL VOLTAGE/FREQ. 12W240 VAC 60 Hz MAX.AMPERAGE 200 A CONFORMS TO NEUTRAL BAR 0 24NEU225B NEUTRAL CURRENT /VOLTS 225 A / 0 V ��I UL STD 67, GROUND BAR 0 GBK2120 MAX.CONTINUOUS CURRENT 166 A V UL STD 869A, MAX.BRANCH CIRC,BRKR. 125 A BREAKER TYPE REFER TO INSTALLATION GUIDE C US UL STD 1741. DATE OF MFG. MFG.BY SYNCRO CORP. CERTIFIED TO Intertek CSA STD ENVIRONMENT TEMP.RATING -10°C to SWC C22.2 8107.1 ONLY QUALIFIED PERSONS MAY ACCESS BEHIND THE DEAD FRONT. 5016932 For Model#SV-HUB-01-B SUNPOWER Hub-- Designed and manufactured in the USA. S U N P W E R MODEL NUMBER:SV•HUB-01-6 Indoor/Outdoor(Type 3R) SERIAL NUMBER Suitable for use as service equipment when equipped with a main overcurrent device, installed only per applicable code and manufacturer recommendations,in a vertical orientation. Suitable for use with interconnected parallel electric power production sources. PANEL TYPE PHASE SINGLE PHASE,3 WIRE PANEL VOLTAGE/FREQ. 120,1240VAC 60Hz MAX.AMPERAGE 200A CONFORMSTO NEUTRAL BAR *24NEU225B NEUTRAL CURRENT /VOLTS 225A / OV UL STD 67, GROUND BAR #GBK2120 MAX.CONTINUOUS CURRENT 166A UL STD 869A, MAX.BRANCH CIRC.BRKR. 125 A BREAKER TYPE REFER TO INSTALLATION GUIDE UL STD 1741. DATE OF MFG. MFG.BY SYNCRO CORP. CERTIFIED TO CSA STD ENVIRONMENT TEMP.RATING -20°C to 50`C C22.2#107.1 ONLY QUALIFIED PERSONS r:1AY ACCESS BEHIND THE DEAD FRONT. ❖ PCS Ratings Operating Mode Import Only (Regular"import Only" mode testing was covered, but only with Zero export control and no control on import limit) Maximum PCS controlled current 80A, 100A, 120A, 140A, 160A and 166A max Average Open-loop Response time 1.83 Sec Maximum Open-loop Response time 2.45 Sec This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected.This Verification by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Intertek Page 2 of 5 GFT-OP-11a(22-August-2019) Lntertek Total Quality.Assured. Test List UL 1741 CRD Clause No. Test description Verdict 203.5 Step change in load test Pass 203.6 Step Change in Generation Test Pass 204.4 Export limiting from Energy Storage Systems Pass 205.5 Startup/Self Check Abnormal Tests Pass 205.7 Operating Abnormal Tests Pass ❖ PCS Marking Following marking are applied on Hub+. PCS controlled current setting: ❑ 80 A ❑ 100 A ❑ 120 A ❑ 140 A ❑ 160 A ❑ Other: A WARNING! This sensor is part of a THIS Power Control System. DO NOT REMOVE. CE Any replacement must be same type and TOWARD rating. The maximum operating current of this system may be controlled electronically. Refer to the SunVault Installation Guide for more information. Alternate power sources for this system are controlled by a Power Control System (PCS). The setting of the PCS shall be considered the power source output circuit current. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected.This Verification by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Intertek Page 3 of 5 GFT-0P-11a(22-August-2019) Lntertek Total Quality.Assured. ❖ PCS Manual Hub+instruction manual was provided with PCS information as required. it provides instruction on how to configure PCS.Also,a single line diagram and all the compatible Current Transformers and meters are included in the manual. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected.This Verification by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Intertek Page 4 of 5 GFT-0P-11a(22-August-2019) Lntertek Total Quality.Assured. V Revision Summary Date/ Engineer Description project#site 26-May-2022/ Dishant Patel Updated Model/Type References on Page 1 From G105027239CRT " SV-HUB-01-C(It is paired with SunPower ESS (SV- Base13-12-A OR SV-Base13-12-B, Optional: SV- Energyl3-12-A, SV-Energyl3-12-B)"To" SV-HUB-01- C, SV-HUB-01-B (It is paired with SunPower ESS (SV- Base13-12-A OR SV-Base13-12-B OR EQS-BASE13-11-A, Optional: SV-Energy13-12-A, SV-Energy13-12-13)" Added Date of test 4/21/2022 to 5/10/2022 on Page 1. Added SV-HUB-01-B nameplate on Page 2. Updated Average Open-loop response time from "0.054 sec"to"1.83 sec". END This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Verification.Only the Client is authorized to permit copying or distribution of this Verification.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek.The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected.This Verification by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Intertek Page 5 of 5 GFT-OP-11a(22-August-2019) Datasheet S U M P *.---: WE R` - . and .- . . 1 D °�Go c D y SunVault System Configuration M rn N m Ln 0- m+ m + m + 13-1 19.5-1 26-2 39-2 Included Component Model • One Hub+ One Hub+ One Hub+ • One Hub+ Numbers9 • One SV-BASE13-C One SV-BASE19.5-C Two SV-BASE13-C • Two SV-BASE19.5-C DC Rated Energy 13 kWh 19.5 kWh 26 kWh 39 kWh Max.Usable Energy(DC)' 12 kWh 18 kWh 24 kWh 36 kWh Max.AC Continuous: 28.3 A continuous 56.6 A continuous Backup Output Current Max.AC Output Fault Current 35.0 A 70.0 A AC Overcurrent Protection Device One 40 A/two pole Two 40 A/two pole Rated Single-Phase Load Supported 4.8 kW(up to 5 minutes) 9.6 kW(up to 5 minutes) (120 V) Rated Continuous Charge Power 6.4 kW 12.8 kW (grid tied and backup) Rated Continuous Discharge Power 6.0 kW 12.0 kW (grid tied) Rated Continuous Discharge Power 6.8 kW 13.6 kW (backup) Rated AC Continuous Outpu[ 25.0 A 50.0 A Current(grid tied) Load Start Capabiliry(I PA) 43 A S2 A 86 A 104 A OR— Rated Backup Discharge Power(kW)5 30 minuLes 7.5 8.0 15.0 16.0 10 seconds 8.5 12.0 17.0 24.0 1 second 10.0 12.0 20.0 24.0 SUNPOWER 0 ( INVERTER INVERTER INVERTER INVERTER GATEWAY GATEWAY 1 Some energy reserved for internal consumption. O O O O 2 Tested at 6 kW,25°C conditions. MIO MIO MIO MIO 3 SunVault Hub+rating is 200 A. VAC is not supported this time.5 Val 5 Values are rated at 25°C ambient. bient. 6 Extended exposure reduces battery performance. 7 Two ESS enclosures for 26 kWh and 39 kWh. Hub+ 8 Additional hardware details in installation guide in W 9 SV-BASE13-C and SV-BASE19.5-C ship as the same item and are field marked for 13 kWh or 19.5 kWh;a BASE may be converted in the field to a BASE X. 10 SunVaultis designed and intended for residential use only. Specifications included in this datasheet are subject to change. BATTERIES BATTERIES BATTERIES BATTERIES BASE ESS BASE ESS BASE X ESS BASE X ESS High Energy High Energy Some parameters can vary depending on site-specific conditions. See the SunVault Installation Guide 536685 for guidelines.See www.sunpower.com/facts for additional reference information.Specifications included in this datasheet are subjectto changewithout notice.©2023 Sun Power Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,and SUNVAULT are trademarks or registered trademarks of SunPower Corporation in the U.S.and other countries as well.1-800-SUNPOWER. April 2023 536812 RevG Datasheet SUNP WER' SunPower°SunVaultTM' Energy Storage System (ESS) Performance SunVault Base SunVault Base High Energy Model Number SV-BASE13-C SV-BASE19.5-C DC Rated Energy 13 kWh 19.5 kWh Max.Usable Energy(DC)' 12 kWh 18 kWh Battery Cell Chemistry Lithium iron phosphate(LiFePO4) Nom.Internal Battery Voltage 51.2 V CEC Weighted RTE Efficiencyz >86% Max.AC Continuous Backup Output Current 28.3 A Max.AC Output Fault Current 35 A AC Overcurrent Protection Device 40 A/two pole Nom.AC Voltage(L-N-L) 120/240 VAC 60 Hz,split phase4 Max.Short Circuit Rating 10 kA Max.Single-Phase Load Supported(120 V) 4.8 kW(up to 5 minutes) Power Factor(full-rated power) ±0.85 Rated Continuous Charge Power(Grid tied&Backup) 6.4 kW Rated Continuous Discharge Power(Grid tied) 6.0 kW Rated AC Continuous Output Current(Grid tied) 25.0 A Rated Backup Discharge Power Continuous 6.8 kW • Certifications, • Compliance Seismic Rating IEEE 693-2005,AC-156 Warranty 10 years Environmental Rating10 Indoor and outdoor rated • IFCC Part 15 Subclass B • IEEE 1547 Acoustic Noise Level <50 dBA @ 1 m distance,86°F(30°C) Certifications and • UL 1973(UL 1642) Recommended 32°F to 86°F(0°C to 30oC) Compliance • UL 1741 Operating Temp. • UL 1741 SA(CA Rule 21) • UL 9540 Temp e Ambient Operating 14°F to 122°F(-10°C to 50°C) UL 9540A • UN 38.3 Shelf Ambient Temp. -4°F to 113°F(-20oC to 45°C) UL 67 Initial Energy Reserve 30% Humidity 0-95%(non-condensing) Enclosure Type/ NEMA Type 3R/IP54 SUNPOWER Ingress Rating Max.Elevation 6560 ft(2000 m) MechanicalOw User Interface Mobile app,LED panel Dimensions 64.5 h x 28 w x 14 in.d(164 x 71 x 36 cm)' • SV-BASE:259 lb(117.5 kg) Weight • SV-BASE13:479 lb(217 kg) • SV-BASE19.5:589 lb(267 kg) Mounting Options Wall or floor$ sunpower.com Datasheet SUNP ( WER" SunPower® SunVaultT"° Hub+T^^ Model Numbers SV-HUB-01-A,SV-HUB-01-B Applications Self-supply,backup,and cost savings Special Features 12 Vjumpstart:YES/Generator control:YES/Rapid Power Off:YES • Whole home(up to 200 A service) Supported Backup Configurations • Partial home(up to 400 A service) Max.Allowed Service/Disconnect Rating 200 A Nom.Allowed Service Voltage 120/240 V 60 Hz,split phase Short Circuit Rating' 10 kA/22 kA2 Overcurrent Protection Device Allowed 100-200 A/service entrance rated AC Metering Solar meter:ANSI C12.20,<0.5%RGM I Site meter:<2% Connectivity Ethernet,WiFi,and cellular Backup Transition Seamless Load/Generation Breakers4 Refer to installation guide for available spaces Overvoltage Category OV IV Pollution Degree III Protection Class I Scalabilitys Supports multiple storage and PV array systems in parallel Certifications,Mechanical Warranties, • Compliance Dimensions 17 w x 46 h x 6 in.d(43 x 117 x 15 cm) Warranty 10 years Weight 80 lb(36 kg) Certifications ANSI C12.20(Class 0.5) • CSA C22.2 No.107.1 Mounting Options Indoor/Outdoor and FCC Part 15 Subclass BCompliance • UL67 Conduit Entry Multiple;up to 3 in. UL 869A • UL1741 Environmental Ambient Operating -40F to 1220F(-20°C to 50°C) Temp. Shelf Ambient Temp. -220F to 140OF(-30°C to 60°C) Humidity 0-95%,condensing Enclosure Type/ NEMA Type 3R/IP54 Ingress Rating Max.Elevation 6560 ft(2000 m) Environment Indoor/Outdoor 1 Higher short circuit rating is compatible with external suitable rated equipment. LTI. 2 With external J-Class fuse or CSR breaker.See the SunVault Installation Guide for \I v guidelines. 3 Recommended service-rated circuit breaker type must be installed. o 4 See the SunVoult Installation Guide for guidelines. IntertelC 5 See the SunVoult Installation Guide for guidelines. ' 5016932 Refer to www.sunpower.com/facts for additional reference information. For more details,see extended datasheet www.sunpower.com/datasheets.Specifications SUNPOWER included in this datasheet are subject to changeange without notice. ©2021 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo, SUNVAULT,and Hub+are trademarks or registered trademarks of SunPower Corporation in the U.S.and other countries as well.1-800-SUNPOWER. 536813 RevB Datasheet SUNP WER@ SunPower®SunVaultTm Energy Storage System (ESS): Battery Performance Model Number SPWR-M0012 Rated Energy 6.5 kWh(128 Ah) Max.Usable Energy 6.0 kWh(118 Ah) Nom.Internal Battery Voltage 51.2 V Max.DC Continuous Output Current 96 A Short Circuit Rating 10 kA Overcurrent Protection Device 125 A/two pole Max.Continuous Power(charge/discharge) 4.5 kW/4.5 kW Peak Surge Power(discharge;1 sec.) 5 kW Round-Trip Efficiency @ 25°C 96% Cell Chemistry Lithium iron phosphate(LiFePO4) Overvoltage Category II Pollution Degree III Protection Class EnvironmenLa� Seismic Rating IEEE 693-2005 Dimensions 29.5 in.h x 19 w x 5.3 d(74.5 cm h x 47.5 w x 13.3 d) Environmental Rating Indoor and outdoor(within ESS enclosure) Weight 128 lb(58 kg) Recommended 32°F to 86°F(0°C to 30°C) Mounting Floor mount(within ESS enclosure) Operating Temp. Ambient Operating 14°F to 122°F(-10°C to 50°C) Warranties,Certifications, d Compliance Temp. Warranty 10 years Shelf Ambient Temp. -4°F to 113°F(-20°C to 45°C) FCC Part 15 Subclass B Certifications UL 1642 Humidity 0-95%(non-condensing) and UL 1973 Enclosure Type/ NEMA 3R/IP55 Compliance UL 1998 Ingress Rating UL 9540A Max.Elevation 6560 fit(2000 m) UN 38.3 SUNPOWER SUNPOWER Some parameters can vary depending on site-specific conditions.See ©2020 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,and www.sunpower.com/facts for more reference information.For more details,see extended SUNVAULT are trademarks or registered trademarks of SunPower Corporation in the U.S.and datasheetwww.sunpower.com/datasheets.Specificationsincluded in this datasheet are other countries as well.1-800-SUNPOWER. su bject to change without notice. 536814 RevC P78 February 10, 2023 structural ENGINEERS SunPower 77 Rio Robles San Jose, CA 95134 TEL: (408) 514-4063 Attn: Sunpower— Engineering Department Re: Engineering Certification for the SunPower Corporation Universal Invisimount Mounting System Span Tables and Design Methodology PZSE, Inc.-Structural Engineers has reviewed the SunPower Universal Invisimount Mounting System Span Tables Revision F published September 21, 2021 and Revision G published August 25, 2022, and their design methodology. This certification covers the module clamp, rail analysis, and attachment Tile hook/L bracket components. All information, data, and analysis contained within are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. Minimum Design Loads for Buildings and other Structures, ASCE 7-16 2. 2022 California Building Code, by California Building Standard Commision 3. 2022 California Residential Code, by California Building Standard Commision 4. 2021 International Building Code, by International Code Council, Inc. 5. 2015 Aluminum Design Manual, by The Aluminum Association 6. CPP Wind Tunnel report number 9790, dated February 16 2017. 7. SEAOC PV-2, 2017 8. 2018 NDS, by the American Wood Council 9. UL 2703 Testing report for PV solar panels. 10. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES Component and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7 Chapter 30, and CPP Wind Tunnel test number 9790, dated February 16 2017. Notes: 1) Racking system and panels shall be installed per manufacturer's specifications. 2) Design assumptions are specified in the Inputs pages of attached span tables. 3) Attachment design is based on 5/16" Dia. Lag Screw with 2.5" Embedment into SPF#2 or equivalent per NDS. Designer shall be responsible for verifying project specific site conditions. 4) Wind speeds are LRFD values. 5) Attachment spacing(s) apply to seismic design category E or less. 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 , 916.961.3965 W www.pzse.com Page 1 of 2 Experience I Inlegrity I Empowerment P78 structural ENGINEERS Design Responsibility: These tables are intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, these tables should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether these tables are applicable to the project, and • Understand and determine the appropriate values for all input parameters of these tables. This letter certifies that the loading criteria and design basis for SunPower Universal Invisimount Mounting System Span Tables are in compliance with the Codes above. This certification excludes the capacity check of the building structure to support the loads imposed on the building by the array, such as bending strength of roof rafters spanning between supports. This requires additional knowledge of the building and is outside the scope of the design tool and our review. If you have any questions on the above, do not hesitate to call. Prepared By: DIGITALLY SIGNED PZSE, Inc. - Structural Engineers Roseville, CA ROFESS/pN NNETH Zql F Cy �fi w m No.S3878 yTS"RUCTURP� ��\P F OF CAS-�F� 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 W www.pzse.com Page 2 of 2 Experience Inlegrity I Empowerment SUMP WER ' ' Roof Roof: 1 Zone 1 Zone 2 Zone 3 Designed attachment spacing 72 in 72 in 24 in Maximum Allowable Cantilever 24 in 17 in 10.0 in Worst Case Uplift 723 plf 1431 plf 2227 plf Worst Case Downward 45 plf 45 plf 45 plf User input Roof 1 Group ID 1 Ground Snow Load pg 0.0 psf Basic Wind Speed V 130.0 mph Wind Exposure Category C Topographic Factor Kt 1.0 Seismic Parameter SS 3.0 g Mean Roof Height h 15 ft Roof Slope 18 degrees Rafter Spacing 24 in Building Least Horizontal Dimension width bldg30 ft Panel Model 96 cell Panel Orientation Portrait Rail Direction Parallel to ridge Attachment Type Quick Hook Kit, 6" base, curved and flat tile, (QuickMount, QMHSS) Page 2 of 6 Roof 1 Group ID 1 Panel Orientation: Portrait Rail Direction: Parallel to ridge Load Calculation Parameters Rail tributary width 2.6 ft Flat roof snow load pf 0.00 psf Wind velocity pressure qh 29 psf Service Loads Dead Load pd 2.81 psf Sloped Roof Snow Load ps 0.00 psf Wind Load Upward Zone 1 pw_zone1 -25.98 psf Wind Load Upward Zone 2 pw_zone2 -49.07 psf Wind Load Upward Zone 3 px_zone3 -75.04 psf Wind Load Downward pw_down 14 psf Seismic Load Fp 4.5 Seismic Load Fp_upper_limit 1.7 Seismic Load Fp_lower_limit 9.0 Seismic Load Fp_eqn 4.5 Load Combinations 1.4D Combo 1 9.6 plf 1.2D+1.6S+0.5W Combo 2 27 plf 1.2D+0.5S+1.OW Combo 3 45 plf 0.9D+1.OW Combo 4(Zone 1) -60.23 plf 0.9D+1.OW Combo 5(Zone 2) -119.22 plf 0.9D+1.OW Combo 6(Zone 3) -185.59 plf 1.2D+1.OE+0.2S Combo 11 7.4 plf 1.4D Combo 7 3.1 plf 1.2D+1.6S Combo 8 2.7 plf 1.2D+0.5S Combo 9 2.7 plf 0.9D Combo 10 2.0 plf 1.2D+1.OE+0.2S Combo 12 14 plf Worst Case Uplift Zone 1 WCzone1 60 plf Worst Case Uplift Zone 2 WCzone2 119 plf Worst Case Uplift Zone 3 WCzone3 186 plf Worst Case Downward WCdown 45 plf Worst Case Seismic Demand WCeq 7.4 plf Worst Case Shear for Uplift Cases WCshear_up 2.0 plf Worst Case Shear for Downward Cases WCshear_down 3.1 plf Worst Case Shear for Seismic Cases WCshear_eq 14 plf Roof Wind Zone Dimensions Width of edge and corner zones a 3.0 ft Maximum Allowable Spacing of Maximum allowable attachment spacing, Lallowed_zone1 72 in Maximum allowable attachment spacing, Lallowed_zone2 72 in Maximum allowable attachment spacing, Lallowed_zone3 30 in Maximum allowable cantilever,zone 1 Cantileverzone1 24 in Maximum allowable cantilever,zone 2 Cantileverzone2 17 in Maximum allowable cantilever,zone 3 Cantileverzone3 10 in Rail Bending Rail Bending Up Strength Mn_rail_up 548 lb-ft Rail Bending Down Strength Mn—rail—down 580 lb-ft L-Foot L-Foot Tension Strength Tn_L-Foot 510.0 lb L-Foot Compression Strength Cn_L-Foot 999.0 lb L-Foot Shear Strength Vn_L-Foot 195.0 lb Tile Hook Tile Hook Tension Strength Tn_hook 530 lb Tile Hook Compression Strength Cn_hook 450 lb Tile Hook Shear Strength for Compression Vn_hook_down 247 lb Tile Hook Shear Strength for Tension Zone 1 Vn_hook_z1 237 lb Tile Hook Shear Strength for Tension Zone 2 Vn_hook_z2 145 lb Tile Hook Shear Strength for Tension Zone 3 Vn_hook_z3 43 lb Tile Hook Shear Strength for EQ Case Vn_hook_eq 316 lb Page 3 of 6 User input Roof 1 Group ID 2 Ground Snow Load pg 0.0 psf Basic Wind Speed V 130.0 mph Wind Exposure Category C Topographic Factor Kt 1.0 Seismic Parameter SS 3.0 g Mean Roof Height h 15 ft Roof Slope 18 degrees Rafter Spacing 24 in Building Least Horizontal Dimension width bldg30 ft Panel Model 96 cell Panel Orientation Portrait Rail Direction Parallel to ridge Attachment Type Quick Hook Kit, 6" base, curved and flat tile, (QuickMount, QMHSS) Page 4 of 6 Roof 1 Group ID 2 Panel Orientation: Portrait Rail Direction: Parallel to ridge Load Calculation Parameters Rail tributary width 2.6 ft Flat roof snow load pf 0.00 psf Wind velocity pressure qh 29 psf Service Loads Dead Load pd 2.81 psf Sloped Roof Snow Load ps 0.00 psf Wind Load Upward Zone 1 pw_zone1 -25.98 psf Wind Load Upward Zone 2 pw_zone2 -49.07 psf Wind Load Upward Zone 3 px_zone3 -75.04 psf Wind Load Downward pw_down 14 psf Seismic Load Fp 4.5 Seismic Load Fp_upper_limit 1.7 Seismic Load Fp_lower_limit 9.0 Seismic Load Fp_eqn 4.5 Load Combinations 1.4D Combo 1 9.6 plf 1.2D+1.6S+0.5W Combo 2 27 plf 1.2D+0.5S+1.OW Combo 3 45 plf 0.9D+1.OW Combo 4(Zone 1) -60.23 plf 0.9D+1.OW Combo 5(Zone 2) -119.22 plf 0.9D+1.OW Combo 6(Zone 3) -185.59 plf 1.2D+1.OE+0.2S Combo 11 7.4 plf 1.4D Combo 7 3.1 plf 1.2D+1.6S Combo 8 2.7 plf 1.2D+0.5S Combo 9 2.7 plf 0.9D Combo 10 2.0 plf 1.2D+1.OE+0.2S Combo 12 14 plf Worst Case Uplift Zone 1 WCzone1 60 plf Worst Case Uplift Zone 2 WCzone2 119 plf Worst Case Uplift Zone 3 WCzone3 186 plf Worst Case Downward WCdown 45 plf Worst Case Seismic Demand WCeq 7.4 plf Worst Case Shear for Uplift Cases WCshear_up 2.0 plf Worst Case Shear for Downward Cases WCshear_down 3.1 plf Worst Case Shear for Seismic Cases WCshear_eq 14 plf Roof Wind Zone Dimensions Width of edge and corner zones a 3.0 ft Maximum Allowable Spacing of Maximum allowable attachment spacing, Lallowed_zone1 72 in Maximum allowable attachment spacing, Lallowed_zone2 72 in Maximum allowable attachment spacing, Lallowed_zone3 30 in Maximum allowable cantilever,zone 1 Cantileverzone1 24 in Maximum allowable cantilever,zone 2 Cantileverzone2 17 in Maximum allowable cantilever,zone 3 Cantileverzone3 10 in Rail Bending Rail Bending Up Strength Mn_rail_up 548 lb-ft Rail Bending Down Strength Mn—rail—down 580 lb-ft L-Foot L-Foot Tension Strength Tn_L-Foot 510.0 lb L-Foot Compression Strength Cn_L-Foot 999.0 lb L-Foot Shear Strength Vn_L-Foot 195.0 lb Tile Hook Tile Hook Tension Strength Tn_hook 530 lb Tile Hook Compression Strength Cn_hook 450 lb Tile Hook Shear Strength for Compression Vn_hook_down 247 lb Tile Hook Shear Strength for Tension Zone 1 Vn_hook_z1 237 lb Tile Hook Shear Strength for Tension Zone 2 Vn_hook_z2 145 lb Tile Hook Shear Strength for Tension Zone 3 Vn_hook_z3 43 lb Tile Hook Shear Strength for EQ Case Vn_hook_eq 316 lb Page 5 of 6 Simple and Fast Installation Integrated module-to-rail grounding Pre-assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates even module spacing Simple,pre-drilled rail splice UL 2703 Listed integrated grounding Flexible Design _ - Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management Customer-Preferred Aesthetics #1 module and#1 mounting aesthetics Best-in-class system aesthetics Elegant Simplicity Premium,low-profile design Black anodized components SunPower° InvisiMountTM is a SunPower-designed Hidden mid clamps and end clamps rail-based mounting system. The InvisiMount system hardware,and capped,flush rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics. • Built for use with SunPower DC and AC modules The InvisiMount product was specifically envisioned and Best-in-class system reliability and aesthetics Combine with SunPower modules and engineered to pair with SunPower modules. The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers. ,q. `� llllllJ O Y sunpower.com a V� Y.:1 InvisiMount Component Module*/Mid Clamp and Rail Module*/End Clamp and Rail P_.'M�Ppw Mid Clamp End Clamp Rail&Rail Splice Ground Lug Assembly End Cap in ft InvisiMount ComponentDetails InvisiMountOperating Conditions Component Material Weight Temperature -40°C to 90°C(-40°F to 194°F) Max.Load 2400 Pa uplift Mid Clamp Black oxide stainless steel AISI 304 63 g(2.2 oz) 5400 Pa downforce End Clamp Black anodized aluminum alloy 6063-T6 110 g(3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m(9 oz/ft) InvisiMount Warranties d Certifications Rail Splice Aluminum alloy 6005-T5 830 g/m(9 oz/ft) Warranties 25 year product warranty Ground Lug 304 stainless 5-year finish warranty Assembly (A2-70 bolt;tin-plated copper lug) 106.5 g/m(3.75 oz) End Cap Black acetal(POM)copolymer 10.4 g(0.37 oz) UL 2703 Listed Certifications Class Afire rating when distance between Roof Attachment Hardware ••• -• by roof surface and bottom of SunPower DesignInvisiMount System module frame is<-3.5" Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Roof Attachment Har• Curved and Flat Tile Roof Attachment Universal Interface for Other Roof Attachments Refer to roof attachment hardware manufacturer's documentation *Module frame that is compatible with the InvisiMount system required for hardware interoperability. ©2015 SunPower Corporation. All Rights Reserved. SUNPOWER,the SUNPOWER logo,and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation.All other trademarks are the property of their respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. Document#509506 Rev B • REPLACETILE • . RAILED RESIDENTIALROOFS ,r LightSpeed Tile Replace system for rails / S the installed Flat tile installed W the installed Pegasus Solar's LightSpeed Tile Replace system for rails significantly reduces installation times by eliminating the need to cut roof tiles. Also, the replaced roof tiles can be used as spares to replace cracked tiles. The top flashing is shaped to seamlessly replace Flat, S, or W tiles, and maintain the waterproof integrity of the roof. • Eliminates cutting of roof tiles • Replaces Flat, S, or W shaped tiles • Universal on battened or batten-less roofs • Provides spare tiles to replace broken tiles • 1" tall cone with Watertight boot provides superior waterproofing Use with any standard L-feet for traditional rail mounting systems. Sleds and lag screws are supplied in packages of 6. Pegasus SolarTile Replace flashings come in Flat, S, •• West Ohio Aveand W shapes, and are supplied with Richmond•38.9655 CA 94804 Posts and EPDM Boots in packages of 6. .-•. Sled installed Roof tile re-installed over Sled i Tile Replace Flashing installation Mounting Post installation Specifications Tile Replace for Rails Flashing Construction One-piece Formed Metal in Flat, S,W Shapes Fits most Flat,S,and W-shaped Tile Compatibility Roof Tiles Rail Compatibility Most Standard L-Feet Batten/Batten-less Fully Adjustable without Adjustment Additional Hardware Waterproofing 1"Elevated Cone with EPDM Boot East/West Adjustment +/-7",14"Total North/South Adjustment +/ 1/2"After Lags Installed Post Installation Before or After Flashing Installation, Simple Twist-Lock Post Construction Aluminum w/Pre-Installed SS T-bolt Flashing Finish Dark Bronze • • Sled Installation Hardware (2)5/16"x4-1/2"SS Lag Screws L-Foot installed • • • •,••, Testing and Certifications UL STD 2703,ASCE 7-05&7-10 •: . •. Weight 6.3lbs/2900gr Patents Pending.All rights reserved. •-•. • - ©2016 Pegasus Solar Inc. LAm) i Le Li Advancing Renewable Technology ACCAcme Cable Clips ACME Cable Clips simplify wire management and create a cleaner aesthetic to solar PV arrays. The clips are made of corrosion resistant stainless steel and are designed to prevent damage to cable insu- lation. The easy to install and remove design only requires a flat head screwdriver and can be reused, unlike zip ties. The universal design fits most modules and can hold one or two wires. • Made with corrosion resistant 300 series stainless steel • Dual wire compartments • Special tab for easy installation and removal with flat-head screwdriver • Designed to prevent damage to cable insulation • Sized for USE-2 cable (5-5.4mm) or PV cable (6.8-7.2mm) ACC ACC- PV Holds: 1 to 2 USE-2 wires Holds: 1 to 2 PV wires or 1 PV wire DC Power Systems (800) 967-6917 wwwA power-systems.com Contact us at: 845.247.4708 www.we-lic.com WEEB® LUG WiLeLi The WEEB°Lug consists of a WEEB°washer, lay-in lug, and hardware. It is used with one solid or stranded copper wire (14AWG to 6AWG), or two copper wires (12AWG to 10AWG)to provide a continuous ground on roof or ground mounted solar systems. Unlike traditional lay-in lugs, the WEEB°Lug does not require surface preparation on rail or module to install. The WEEB° Lug is installed using stainless steel mounting hardware. When the hardware is tightened the WEEWWashers' specialized teeth embed into anodized aluminum, galvanized steel, or any electrically conductive metal to establish a gas tight electrical connection. The tin-plated Lug assures minimum contact resistance and protection against corrosion. Copper wire is clamped by a 1/4-28 stainless steel screw, which is horizontal to the tang for easy access when mounted under a PV module. The low profile of the WEEB° Lug allows it to be installed in a variety of positions. Catalog Item# L x W x H Hole Hardware Torque WEEB-LUG-6.7 30020109 1.60"x 0.71"x 0.47" 1/4 inch hardware- included unassembled 0.266" WEEB-LUG-6.7AS 30020110 1.60"x 0.71"x 0.47" 1/4 inch hardware- included assembled 7 ft. lbs.for WEEB-LUG-8.0 30020111 1.60"x 0.87"x 0.47" M8 or 5/16 inch hardware- terminal screw not included 10 ft. lbs.for WEEB-LUG-8.OAS 50010335 1.60"x 0.87"x 0.47" 5/16 inch hardware- mounting included assembled hardware 0.323°WEEB-LUG-8.OUN 50023920 1.60"x 0.87"x 0.47" 5/16 inch hardware- w/Penetrox-A included unassembled on threads WEEB-LUG-15.8 30020112 1.60"x 0.71"x 0.47" M8 or 5/16 inch hardware- not included W Made of corrosion-resistant, tin-plate copper 4po Design ensures for easy installation - Available �� -With WEEB°washer technology � :. -Assembled and unassembled -With or without installation hardware • Low profile design No surface preperation on rail or module required • Reliability throughout the lifetime of the PV system • Multiple equipment ground conductor allowance: One 14 AWG to 6 AWG or two 10 AWG, two 12 AWG ----- - -------- Listed to ANSI/UL 467 by Intertek ETL _-=-` " _- CSA Certified to C22.2 No. 41 ___ ._..1 -� Custom designs available upon request Customer Service Department 7 Aviation Park Drive t Londonderry NH 03053 c us 1-800-346-4175 �. -- CO US (International) - - Intertek www.burndy.com __ 4004188 WILEY GROUNDING LUG WILeLi The WILEY Grounding Lug consists of a lay-in lug and terminal screw. It is used with one solid or stranded copper wire (14AWG to 6AWG), or two copper wires (12AWG to 10AWG)to create an electrical connection between two pieces of non-anodized aluminum, galvanized steel, or any electrically conductive metal. The tin- plated WILEY Grounding Lug assures minimum contact resistance and protection against corrosion. Copper wire is clamped by a 1/4-28 stainless steel screw, which is horizontal to the tang for easy access when mounted under a PV module. The low profile of the WILEY Grounding Lug allows it to be installed in a variety of positions. Catalog Item # L x W x H Hole Hardware Torque WILEYLUG6.7 50028861 1.60"x 0.71"x 0.47" 0.266" Terminal screw included- 7 ft. lbs.for WEEBTm not included terminal screw WILEYLUG8.0 50028866 1.60"x 0.87"x 0.47" Terminal screw included- WEEBTm not included 10 ft. lbs.for WILEYLUG8.2 50028869 1.60"x 0.71"x 0.47" Terminal screw included- mounting 0.323" WEEBTm not included hardware WILEYLUG15.8 50028872 1.60"x 0.71"x 0.47" Terminal screw included- w/Penetrox-A WEEBTm not included on threads • Material: tin-plated copper • Outdoor rated • Low profile design • Multiple equipment ground conductor allowance: One 14 AWG to 6 AWG or two 10 AWG, two 12 AWG Listed to ANSI/UL 467 by Intertek ETL ,0/ -+i e* Customer Service Department "+. Y t.;•� - , 7 Aviation Park Drive Londonderry NH 03053 c us 1-800-346-4175 uano 1-603-647-5299 (International) Intertek www.burndy.com 4004188 Loadcenters and Circuit Breakers 1 .2 Type BR Loadcenters and Circuit Breakers Single-Phase—Main Lug Loadcenters Single-Phase Three-Wire-120/240 Vac—Insulated/Bondable Split Neutral Maximum Number Wire Size Range Main 1-Inch(25.4 mm) Enclosure Box Cu/AI 60°C or 75°C Loadcenter Ampere Rating Spaces Circuits Type Trim Type Size for Main Lugs Catalog Number Surface Outdoor 70 2 4 Indoor Surface(no door) 5 #8—#2 BR2470SP �z 2 4 Indoor Surface(no door) 5 BR24L70SGP s 2 4 Outdoor — 5R BR24L70RP�® 2 4 Indoor Flush(no door) 5 BR24L70FP 2 4 Indoor Flush(no door) 5 BR24L70FGP 4* 125 2 4 Indoor Surface(no door) 6 #14-1/0 BR24L125SP Flush Outdoor 2 4 Outdoor — 6R BR24L125RP O 2 4 Outdoor — 6R BR24L125RSEP(0© 2 4 Outdoor — 6R BR24L125RSE2P z)s W 2 4 Indoor Flush(no door) 6 BR24L125FP D z 4 8 Indoor Surface(no door) 7 #14-1/0 BR48L125SP 4 8 Indoor Surface(no door) 7 BR48L125SGP Surface(No Door) 4 8 Outdoor — 7R BR48L125RP 04 4 8 Indoor Flush(no door) 7 BR48L125FP D a 4 8 Indoor Flush(with door) 7 BR48L125FDP 4 8 Indoor Flush(no door) 7 BR48L725FGP 6 12 Indoor Surface(no door) 7 #1441 BR612L125SP O® 6 12 Indoor Surface(no door) 7 BR612L125SGP 00 Flush(No Door) 6 12 Indoor Surface(with door) 7 BR612L125SDP O® 6 12 Indoor Surface(with door) 7 BR612L125SDGP 0 6 12 Outdoor — 7R BR612L125RP 4 6 12 Indoor Flush(no door) 7 BR612L125FP O® 6 12 Indoor Flush(no door) 7 BR612L125FGP s 6 12 Indoor Flush(with door) 7 BR612L125FDP Outdoor 6 12 Indoor Flush(with door) 7 BR612L125FDGP s 8 16 Indoor Surface(no door) 7 #1441 BR816L125SP O® 8 16 Indoor Surface(no door) 7 BR816L125SGP @@ 8 16 Indoor Surface(with door) 7 BR816L125SOP(D@ 8 16 Indoor Surface(with door) 7 BR816L125SDGP @@ 8 16 Outdoor — 7R BR816L125RP 8 16 Indoor Flush(no door) 7 BR816L125FP O® 8 16 Indoor Flush(no door) 7 BR816L125FGP�© 8 16 Indoor Flush(with door) 7 BR816L125FDP TO 8 16 Indoor Flush(with door) 7 BR816L125FDGPO�W Notes (D Ground bar kits priced separately.See Page V1-T1-60. —For 2/4 circuit Loadcenters,use GBK5 or GBK520 ground bar. —For 4/8,6/12 and 8/16 circuit loadcenters,use GBK10 ground bar. —Ground bars mount to the left side wall of the enclosure for the 4/8,6/12 and 8/16 circuit loadcenters. O Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). (A) Ground bar GBK5 is installed. ® Rainproof panels are furnished with hub closure plates.For rainproof hubs,refer to Page V141-60. © CSA and UL approved. © Neutral/ground holes(6)#14-6 and(3)#14-2/0 AWG Cu/AI. For use as service entrance applications only. ® Neutral/ground holes(6)#14-6 and(3)#14-1/0 AWG Cu/AI. (A) Suitable for use as service equipment when not more than two service disconnecting mains are provided orwhen not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard(see Article 408.34 of the NEC). ® Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard(see Article 408.34 of the NEC). 0 Ground bar GBK10 is installed. © Ground bar GBK14 is installed. Box sizes Pages V7-T7-61 through V141-64. Volume 1—Residential and Light Commercial CA081000O2E—January 2O13 www.eaton.com VI-T1-47 1 .2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Dimensions Approximate Dimensions in Inches (mm) Residential/Commercial/New York City Loadcenters,Unit Enclosures-Box Sizes Note:Box sizes do not include covers/fronts. Residential Loadcenters-NEMA Type 1 Indoor Commercial Loadcenters-NEMA Type 1 Indoor Box Size Height Width Depth Box Size Height Width Depth Al 15.00(381.0) 11.25(285.8) 3.75(95.3) 19 44.00(1117.6) 16.16(410.4) 6.25(158.8) 31 16.75(425.5) 14.31(363.5) 3.88(98.4) 20 44.00(1117.6) 16.16(410.4) 6.25(158.8) 32 18.75(476.3) 14.31(363.5) 3.88(98.4) 22 54.00(1371.6) 16.22(412.0) 6.31(160.3) C1 21.00(533.4) 14.31(363.5) 3.88(98.4) 24 66.50(1689.1) 16.22(412.0) 6.31(160.3) C2 23.00(584.2) 14.31(363.5) 3.88(98.4) C4 27.00(685.8) 14.31(363.5) 3.88(98.4) D1 29.13(739.8) 14.31(363.5) 3.88(98.4) Commercial Loadcenters-NEMA Type 3R Outdoor G1 34.13(866.8) 14.31(363.5) 3.88(98.4) Box Size Height Width Depth L1 39.00(990.6) 14.31(363.5) 3.88(98.4) 42 38.00(965.2) 16.31(414.3) 6.38(161.9) L2 45.00(1143.0) 14.31(363.5) 3.88(98.4) 43 44.00(1117.6) 16.31(414.3) 6.38(161.9) L3 48.38(1228.3) 14.31(363.5) 3.88(98.4) 46 54.00(1371.6) 16.31(414.3) 6.38(161.9) 2 8.63(219.1) 5.00(127.0) 3.50(88.9) 47 66.56(1690.7) 16.31(414.3) 6.38(161.9) 3 9.44(239.7) 4.50(114.3) 3.00(76.2) 4 13.00(330.2) 11.00(279.4) 3.56(90.5) New York City Loadcenters-NEMA Type 1 Indoor 5 9.44(239.7) 4.50(114.3) 3.00(76.2) Box Size Height Width Depth 6 12.00(304.8) 6.88(174.6) 4.50(114.3) A 38.00(965.2) 18.13(460.4) 5.00(127.0) 7 13.00(330.2) 11.00(279.4) 3.56(90.5) B 44.00(1117.6) 18.13(460.4) 5.00(127.0) 9 14.50(368.3) 6.50(165.1) 3.50(88.9) C 66.50(1689.1) 18.13(460.4) 6.25(158.8) Residential Loadcenters-NEMA Type 31113 Outdoor Types ECB and ECC Unit Enclosures-NEMA Type 1 Indoor Box Size Height Width Depth Height Width Depth 131 R 16.75(425.5) 14.31(363.5) 5.19(131.8) 23.25(590.6) 8.88(225.4) 4.50(114.3) 13219 18.75(476.3) 14.31(363.5) 5.19(131.8) C3R 25.00(635.0) 14.31(363.5) 5.19(131.8) D1R 29.13(739.8) 14.31(363.5) 5.19(131.8) Types ECB and ECC Unit Enclosures-NEMA Type 313 G1 R 34.13(866.8) 14.31(363.5) 5.19(131.8) Outdoor L1R 39.00(990.6) 14.31(363.5) 5.19(131.8) Height Width Depth L2R 45.00(1143.0) 14.31(363.5) 5.19(131.8) 23.68(601.7) 9.31(236.5) 5.44(138.1) 1_319 48.75(1238.2) 14.31(363.5) 5.19(131.8) 2R 8.63(219.1) 5.00(127.0) 3.50(88.9) 3R 9.44(239.7) 4.50(114.3) 3.00(76.2) 4R 13.00(330.2) 11.00(279.4) 3.56(90.5) 5R 9.44(239.7) 4.50(114.3) 3.00(76.2) 6R 11.75(298.5) 6.50(165.1) 4.50(114.3) 7R 13.00(330.2) 11.00(279.4) 3.56(90.5) 8R 27.00(685.8) 10.50(266.7) 4.75(120.7) 9R 14.25(362.0) 6.50(165.1) 4.00(101.6) MR 21.00(533.4) 14.31(363.5) 5.19(131.8) V1-T7-66 Volume 1-Residential and Light Commercial CA08100002E-December 2014 www.eaton.com Product Data Sheet DU222RB SWITCH NOT FUSIBLE GD 240V 60A 2P NEMA3R SQUARE D by Schneider E i,:-�c List Price $353.00 USD 7 Availability Stock Item:This item is normally stocked in our distribution facility. Vol Technical Characteristics Number of Poles 2-Pole Terminal Type Lugs Type of Duty General Duty Maximum Voltage Rating 240VAC Wire Size #10 to#2 AWG(AI)-#14 to#2 AWG(Cu) Action Single Throw Ampere Rating 60A Approvals UL Listed File Number E2875 Enclosure Rating NEMA3R Enclosure Type Rainproof and Sleet/Ice proof(Indoor/Outdoor) Factory Installed Neutral No Disconnect Type Non-Fusible Mounting Type Surface Shipping and Ordering Category 00106-Safety Switch,General Duty,30-200 Amp, NEMA3R Discount Schedule DE1A GTIN 00785901491491 Package Quantity 1 Weight 4.7 lbs. Availability Code Stock Item:This item is normally stocked in our distribution facility. Returnability Y Country of Origin MX As standards,specifications,and designs change from time to time, please ask for confirmation of the information given in this document. Generated:11/17/2011 17:11:35 ©2011 Schneider Electric.All rights reserved. Schneider jo Electric