Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PV PLANS (2)
COVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS PAGE REV: A 2/3/2023 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 CARON MARSHALL 73576 ADOBE SPRINGS DR, PALM DESERT, CA, 92260 PROJECT NUMBER: 113R-576MARS SHEET DESIGNER: TYLER STEPHENS CUSTOMER RESIDENCE: TEL. (909) 239-2544 APN: 620-102-001 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PAGE # DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-1.0 VICINITY MAP • SYSTEM SIZE: 4740W DC, 3800W AC • MODULES: (12) JA SOLAR: JAM54S31-395/MR • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: SE3800H-USMN • RACKING: SNAPNRACK SERIES UR40 ; ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING SNR-DC-00438 • ALL WORK SHALL COMPLY WITH 2022 CRC/CBC/CEBC, MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2022 CEC. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2022 CEC. • PHOTOVOLTAIC SYSTEM IS FUNCTIONALLY GROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.41. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER 690.12(B). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 13.7 AMPS MODULE SHORT CIRCUIT CURRENT. • 21.4 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (A) & 690.8 (B)]. • CONSTRUCTION WORK HOURS OCTOBER 1ST TO APRIL 30TH MONDAY - FRIDAY 7:00AM TO 5:30PM SATURDAY 8:00AM TO 5:00PM SUNDAY NOT ALLOWED GOVERNMENT HOLIDAY CONSTRUCTION WORK NOT ALLOWED CONSTRUCTION WORK HOURS - MAY 1ST THROUGH SEPTEMBER 30TH MONDAY - FRIDAY 6:00AM TO 7:00PM SATURDAY 8:00AM TO 5:00PM SUNDAY NOT ALLOWED GOVERNMENT HOLIDAY CONSTRUCTION WORK NOT ALLOWED #SSTAMPCS #ESTAMPCS ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT (E)EXISTING ESS ENERGY STORAGE SYSTEM EXT EXTERIOR INT INTERIOR MSP MAIN SERVICE PANEL (N)NEW NTS NOT TO SCALE OC ON CENTER PRE-FAB PRE-FABRICATED PSF POUNDS PER SQUARE FOOT PV PHOTOVOLTAIC RSD RAPID SHUTDOWN DEVICE TL TRANSFORMERLESS TYP TYPICAL V VOLTS W WATTS LAN LANDSCAPE POR PORTRAIT RAIL STANDOFFS & FOOTINGS SOLAR MODULES LEGEND SCALE: NTS MAIN PANEL INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) PV LOAD CENTER SUB-PANEL CB ATTIC VENT FLUSH ATTIC VENT PVC PIPE VENT SATELLITE DISH T-VENT CHIMNEY FIRE SETBACKS SUNRUN METER METAL PIPE VENT DEDICATED PV METER SERVICE ENTRANCE IQ COMBINER BOX HARDSCAPE PROPERTY LINE INTERIOR EQUIPMENT SHOWN AS DASHED PL SE MP SP LC SM PM INV AC DC Template_version_4.0.87 SHEET INDEX #SSTAMMMPCPCCCCCPCCPCCCPCPCCPCPPPCPCPPCCPPPCCPPCCPSSSSSSSSSSSSSSSSSSSSSSS #ESTTTTTSTTTTTSTTSTTTTTTTTTTTTTTTTTSTTTSAMAAMAMAMAMAMMMAMAMAMAMAMAMAMAAMAMAMAMAMAMMMAAMAMAMMAMAAMAMMAMAAAAMMMAAAPCPCPCCCPCCCPCPCPCCCPCPCPPCPCCPCPCPCCCPPCPCPPCPCPPCPPPPCCCCPPPCPPSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS 6/30/2024 STAMPED 02/03/2023 PL PL PL PL PL PL P L P L PL PL PL PL PL PAGE REV: A 2/3/2023 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 CARON MARSHALL 73576 ADOBE SPRINGS DR, PALM DESERT, CA, 92260 PROJECT NUMBER: 113R-576MARS SHEET DESIGNER: TYLER STEPHENS CUSTOMER RESIDENCE: TEL. (909) 239-2544 APN: 620-102-001 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 SITE PLAN ARRAY PITCH PV AREA (SQFT) AR-01 19° 252.3 TRUE AZIM MAG AZIM 154°166° PV-2.0 #SSTAMPSP #ESTAMPSP SITE PLAN - SCALE = 1/16" = 1'-0" Template_version_4.0.87 NOTES: x RESIDENCE DOES NOT CONTAIN ACTIVE FIRE SPRINKLERS. ARRAY DETAILS: x TOTAL ROOF SURFACE AREA: 2335 SQFT. x TOTAL PV ARRAY AREA: 252.3 SQ FT. x PERCENTAGE PV COVERAGE: (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE AREA) * 100 = 10.8% MODULES WERE DESIGNED AT LEAST 18'' FROM THE ROOF RIDGE. A D O B E S P R I N G S D R FAWN SPRINGS D R (E) RESIDENCE ROOF PATHWAYS (3' TYP) FIRE SETBACKS (18" TYP) (E) GATE (N) ARRAY AR-01 MP SE INV (E) FENCE LADDER ACCESS POINT LADDER ACCESS POINT ROOF PATHWAYS (3' TYP) (E) PATIO (E) PATIO (E) DRIVEWAY EQUIPMENT ELEVATION - SCALE: NTS 22'-4"21'-11" #SSSTTSTSTTTTSTSTSTSTSTSTSTSTSTSTSTTSTSTSTTSTTSTSTTSTSSTTTTSTSSTSSSSTAMAMAMAMAMMAMMAMAMAMAMMAMAMMAMAMAMAMMAMAMAMAMAMAMAMAMAMAAAAAMAMAAMAMAMMMAMMMMMAAMAAPSPSPSSPSPSPSSPPSPSPSPSSPSPSSPSPSPSPPSSPSSSPSSPSSSSSSSSPSPPSSSPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPPP #ESTAMMMMMMMMPSPSPSPPSPSPPSPSPSPSPPSPSPSPSSPSPSPSSPPPPPPPPPPPP 6/30/2024 STAMPED 02/03/2023 PAGE REV: A 2/3/2023 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 CARON MARSHALL 73576 ADOBE SPRINGS DR, PALM DESERT, CA, 92260 PROJECT NUMBER: 113R-576MARS SHEET DESIGNER: TYLER STEPHENS CUSTOMER RESIDENCE: TEL. (909) 239-2544 APN: 620-102-001 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 D1 - AR-01 - SCALE: 3/16" = 1'-0" AZIM:166° PITCH: 19° PV-3.0 LAYOUT #SSTAMP ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 COMP SHINGLE - UR 1-Story 2X4 PRE-FABRICATED TRUSSES 7' - 6"24"ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING SNR-DC-00438 6' - 0"2' - 4"6' - 0" 2' - 3"STAGGERED DESIGN CRITERIA MAX DISTRIBUTED LOAD:3 PSF SNOW LOAD:0 PSF WIND SPEED: 130 MPH 3-SEC GUST. S.S. LAG SCREW 5/16"X4.5": 2.5" MIN. EMBEDMENT Template_version_4.0.87 SOLAR MODULE SNAPNRACK RACKING 4" MODULE ELEVATION DETAIL - SCALE: NTS INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION.* IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ** ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. ** ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. 9'-4"15'-1"4' 1'-9" 17'-1" 11" 6' TYP 6/30/2024 STAMPED 02/03/2023 EXISTING 200A MAIN BREAKER (END FED) FACILITY GROUND(N) 20A PV BREAKER AT OPPOSITE END OF BUSBAR M METER #: SCE 222011-729035 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID EXISTING 200A MAIN PANELFACILITY LOADS 200 A MAIN BUS 3 12 JUNCTION BOX OR EQUIVALENT SOLAREDGE TECHNOLOGIES: SE3800H-USMN 3800 WATT INVERTER LOAD RATED DC DISCONNECT WITH AFCI, RAPID SHUTDOWN COMPLIANT PV MODULES JA SOLAR: JAM54S31-395/MR (12) MODULES OPTIMIZERS WIRED IN: (1) SERIES OF (12) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS S440 CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 PAGE REV: A 2/3/2023 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 CARON MARSHALL 73576 ADOBE SPRINGS DR, PALM DESERT, CA, 92260 PROJECT NUMBER: 113R-576MARS SHEET DESIGNER: TYLER STEPHENS CUSTOMER RESIDENCE: TEL. (909) 239-2544 APN: 620-102-001 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 PV-4.0 ELECTRICAL #ESTAMP SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DC VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT: 4740 W 12 V 380 V 480 V 12.47 A 15 A S440 OPTIMIZER CHARACTERISTICS: MIN INPUT VOLTAGE: 8 VDC MAX INPUT VOLTAGE: 60 VDC MAX INPUT ISC: 14.5 ADC MAX OUTPUT CURRENT: 15 ADC MODULE CHARACTERISTICS JA SOLAR: JAM54S31-395/MR: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 395 W 36.98 V 30.84 V 13.7 A Template_version_4.0.87 RAIL 6-12 AWG BARE COPPER WIRE 5/16"-18 SS BOLT SS SPLIT LOCK WASHER (TORQUE TO 16 FT-LBS) SNAPNRACK GROUND LUG BONDING CHANNEL NUT SS BONDING PINS NOTE: x ALL HARDWARE IS INCLUDED FROM MANUFACTURER x A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY CONTINUOUS ROW OF MODULES x GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL x GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL OR PERPENDICULAR TO RAIL x ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SNAPNRACK GROUNDING SCALE: NTS ALL CONDUCTORS ARE RATED 90 DEGREES CELSIUS. PAGE REV: A 2/3/2023 1125 RESEARCH DR. STE B REDLANDS, CA 92374 PHONE 805.540.7603 FAX 949.215.7778 CARON MARSHALL 73576 ADOBE SPRINGS DR, PALM DESERT, CA, 92260 PROJECT NUMBER: 113R-576MARS SHEET DESIGNER: TYLER STEPHENS CUSTOMER RESIDENCE: TEL. (909) 239-2544 APN: 620-102-001 GILBERT CORREIA, C10, C46 CA CL #750184 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, CEC 2022: 690.54 PV SYSTEM DISCONNECT WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), CEC 2022: 705.12(B)(3)(2) NOTES AND SPECIFICATIONS: x SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE 2022 CEC ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. x SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. x LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. x LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. x SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. x DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) 4" 3" ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), CEC 2022: 690.13(B) !INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC480 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022: 690.31(D)(2)CAUTION: 73576 ADOBE SPRINGS DR, PALM DESERT, CA, 92260 PER CODE(S): NEC 2020 : 705.10, 710.10, CEC 2022: 705.10, 710.10 MULTIPLE SOURCES OF POWER LABEL LOCATION: INSTALLED WITHIN 3' OF RAPID SHUT DOWN SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 WARNING! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2020: 705.12(C), CEC 2022: 705.12(C) THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING! LABEL LOCATION: PV LOAD CENTER (IF APPLICABLE) AND ANY PANEL THAT UTILIZES "THE SUM OF BREAKERS RULE". PER CODE(S): NEC 2020: 705.12 (B)(3)(3), CEC 2022: 705.12 (B)(3)(3) Template_version_4.0.87 SERVICE ENTRANCE AND PV BREAKER DISCONNECT INVERTER (EXT) SOLAR PANELS ON ROOF UR-40 RAIL | UR-60 RAIL FOR USE WITH SNAPNRACK ULTRA SERIES RAILS PENETRATION DETAIL EXPLODED DESCRIPTION:DRAWING NUMBER:SCALE:DESIGNER: APPROVED BY: REVISION: Sunrun South LLC 595 MARKET STREET, 29TH FLOOR Æ” SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 Æ” FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. ULTRA RAIL, ATTACHMENT DETAIL, UR SPEEDSEAL FOOT TO RAFTERSNR-DC-00438 1 3/10/2020 NEW DETAIL 2 6/5/2020 DIE CAST 3 7/22/2020 NAME UPDATE 4 10/2/2020 MIAMI-DADE REV: 4DATE: DNS 10/2/2020 DRAFTER:M.AFFENTRANGER B.PETERSON M.AFFENTRANGER Solar Mounting Solutions MJA BDP MJA MJA BIN: 8 21 4 " 11 2 " 11 2 " 15 8 " SNAPNRACK UR SPEEDSEAL FOOT FOR COMPOSTION ROOF MOUNTING REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS. 5 16 "‘ S.S. LAG SCREW MUST EMBED A MIN. OF 21 2 " INTO STRUCTURAL MEMBER REFER TO SNAPNRACK INSTALLATION MANUAL FOR 5 16 "‘ HARDWARE TORQUE SPECIFICATIONS STRUCTURAL MEMBER SPECIFICATIONS: MINIMUM WOOD GRADE = SPF #2 MINIMUM SPECIFIC GRAVITY = 0.42 ALLOWABLE FASTENER UPLIFT = 820 LBS ALLOWABLE FASTENER LATERAL = 250 LBS MINIMUM FASTENER EDGE DISTANCE = 0.5" MINIMUM FASTENER END DISTANCE = 2.2" STRUCTURAL MEMBER (RAFTER) ROOF DECKING ROOF DECKING, TYP. STRUCUTRAL MEMBER, WOOD RAFTER, TYP. COMP SHINGLE ROOFING, TYP.MODULE HEIGHT OFF ROOF, RANGE: UR-40: 33 8 " - 43 8 " UR-60: 4" - 5" SEALANT 21 2 " MIN. EMBEDMENT INTO WOOD MEMBER SNAPNRACK, ULTRA RAIL SNAPNRACK, UR SPEEDSEAL FOOT SNAPNRACK, 5 16 "P S.S. LAG SCREW, TYP. CAVITY IN UR SPEEDSEAL FOOT IS FILLED WITH SEALANT TO ENCAPSULATE AND PROTECT THE ROOF PENETRATION FROM MOISTURE SNAPNRACK, ULTRA RAIL MOUNT, TAPPED SNAPNRACK, ULTRA RAIL MOUNT, THRU SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING COIL SPRING FOR 3 8 " P BOLT, S.S. OPTIONAL 5 16 "P-18 X 2" BOLT, SERRATED FLANGE, S.S. 5 16 " WASHER, S.S. (MAY INCLUDE NEOPRENE TYPE GASKET) R E E N I IGER LARUTCURTS AINROFILACFOETAT S G N E LANOISSEFORPDERETSE H C A Z HTENEKL N AP Exp. 3-31-23 No. S3878 R U ST O R E D G E ® solaredge.com Optimized battery storage with HD-Wave technology 5HFRUGEUHDNLQJZHLJKWHGHIÀFLHQF\ZLWK 200% DC oversizing Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020, per article 690.11 and 690.12 Embedded revenue grade production data, ANSI C12.20 Class 0.5 6PDOOOLJKWZHLJKWDQGHDV\WRLQVWDOO 0RGXODUGHVLJQIXWXUHUHDG\ZLWKRSWLRQDO upgrades to: Multi-inverter(*), scalable storage solution Single Phase Energy Hub Inverter with Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US 12-25 YEARWARRANTY DC-coupled storage for full or partial home backup Built-in consumption monitoring Direct connection to the SolarEdge smart EV charger SE3000H-US SE3800H-US SE6000H-US SE7600H-US UNITS OUTPUT - AC ON GRID Rated AC Power 3000 3800 6000 7600 W Maximum AC Power Output 3000 3800 6000 7600 W AC Output Voltage Range 211-264 Vac AC Frequency Range (min - nom - max)59.3 - 60 - 60.5(2)Hz Maximum Continuous Output Current 12.5 16 25 32 A GFDI Threshold 1A 7RWDO+DUPRQLF'LáŽRUWLRQ7+'<3 % Power Factor DGMXáŽDEOHWR 8WLOLW\0RQLWRULQJ,VODQGLQJ3URWHFWLRQ&RXQWU\&RQÀJXUDEOH7KUHVKROGV Yes Charge Battery from AC (if Allowed)Yes Typical Nighttime Power Consumption <2.5 W OUTPUT - AC BACKUP(3) Rated AC Power in Backup Operation 2400 3050 4800 6100 W Peak AC Power (<10 sec) in Backup Operation 2700 3400 5400 6900 W AC L-L Output Voltage Range in Backup 211-264 Vac AC L-N Output Voltage Range in Backup 105-132 Vac AC Frequency Range in Backup (min - nom - max) 55 - 60 - 65 Hz Maximum Continuous Output Current in Backup Operation 10 12.7 20 25.5 A Peak AC Current (<10sec) in Backup Operation 11.25 14.2 22.5 30 A GFDI 1A THD <5 % OUTPUT - SMART EV CHARGER AC Rated AC Power 9,600 W AC Output Voltage Range 211-264 Vac AC Frequency Range (min - nom - max) 59.3-60-60.5 Hz 0D[LPXP&RQWLQXRXV2XWSXW&XUUHQW#9JULG39DQGEDWWHU\40 Aac INPUT - DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 400 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection NƼ6HQVLWLYLW\ INPUT - DC (PV) Maximum DC Power 6000 7600 12000 15600 W Maximum Input Current(4)8.5 10.5 16.5 20 Adc 0D[,QSXW6KRUW&LUFXLW&XUUHQW 45 Adc 0D[LPXP,QYHUWHU(à©•FLHQF\99.2 % &(&:HLJKWHG(à©•FLHQF\99 % 2-pole Disconnection Yes INPUT - DC (BATTERY) 6XSSRUWHG%DWWHU\7\SHV /*&KHP5(68+ 1XPEHURI%DWWHULHVSHU,QYHUWHU 1 or 2(5) Maximum Battery Capacity per Inverter 19.6 kWh Continuous Power Per Inverter 5000 W Peak Power 6900 W Max Input Current @240V 18 Adc 2-pole Disconnection Yes Single Phase Energy Hub Inverter with Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1) SMART ENERGY CAPABILITIES Consumption Metering Built - in(6) %DWWHU\6WRUDJH With Backup Interface for service up to 200A; Up to 3 inverters*N:EDFNXSSRZHU*, and 60kWh EDFNXSFDSDFLW\* EV Charging 'LUHFWFRQQHFWLRQWR6PDUW(9FKDUJHU ADDITIONAL FEATURES 6XSSRUWHG&RPPXQLFDWLRQ,QWHUIDFHV 56(WKHUQHW:L)LRSWLRQDO&HOOXODU(7) 5HYHQXH*UDGH0HWHULQJ$16,&Built - in(6) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning ZLWKWKH6HW$SSPRELOHDSSOLFDWLRQXVLQJEXLOWLQ:L)L$FFHVV3RLQWIRUORFDOFRQQHFWLRQ '&9ROWDJH5DSLG6KXWGRZQ39DQG%DWWHU\Yes, according to NEC 2014, NEC 2017 and NEC 2020 690.12 STANDARD COMPLIANCE 6DIHW\8/8/6$8/%8/8/&6$ *ULG&RQQHFWLRQ6WDQGDUGV IEEE1547, Rule 21, Rule 14H Emissions FCC part 15 class B INSTALLATION SPECIFICATIONS $&2XWSXW&RQGXLW6L]H$:*5DQJH PD[LPXP$:* PD[LPXP$:* (9$&2XWSXW&RQGXLW6L]H$:*5DQJH PD[LPXP$:* PD[LPXP$:* '&,QSXW39&RQGXLW6L]H$:*5DQJH PD[LPXP$:* PD[LPXP$:* '&,QSXW%DWWHU\&RQGXLW6L]H$:*5DQJH PD[LPXP$:* PD[LPXP$:* Dimensions with Connection Unit (HxWxD);;;; LQPP Weight with Connection Unit OENJ Noise < 25 dBA Cooling Natural Convection Operating Temperature Range WRWR(7)Ü)Ü& Protection Rating NEMA 4X © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 11/2020/V01/ENG NAM. Subject to change without notice. 3HQGLQJÀUPZDUHXSJUDGH 7KHVHVSHFLÀFDWLRQVDSSO\WRLQYHUWHUVZLWKSDUWQXPEHUV6([[[[+866[[[[[RU6(+8666+[[[[DQGFRQQHFWLRQXQLWPRGHOQXPEHU'&'3+863[+)[ )RURWKHUUHJLRQDOVHWWLQJVSOHDVHFRQWDFW6RODU(GJHVXSSRUW (3) Not designed for standalone applications and requires AC for commissioning $KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVVWDWHG :KHQFRQQHFWLQJWZR/*&KHP5(68EDWWHULHVHDFKEDWWHU\PXVWKDYHDGLIIHUHQWSDUWQXPEHU )RUFRQVXPSWLRQPHWHULQJFXUUHQWWUDQVIRUPHUVVKRXOGEHRUGHUHGVHSDUDWHO\6($&71$RU6($&71$XQLWVSHUER[ )RUERWK\UDQG\UGDWDSODQV Ã&XVWRPHULVUHVSRQVLEOHIRUYHULI\LQJWKDWWKHVLWHORFDWLRQKDVDGHTXDWHPRELOHFRYHUDJHE\WKHWKLUGSDUW\VHUYLFHSURYLGHUSULRUWRDQ\LQVWDOODWLRQE\DFFHVVLQJ https://www.solaredge.com/ Ö¿ products/communication/cellular-communication-options#/ Ã6RODU(GJHVKDOOQRWEHUHVSRQVLEOHRUOLDEOHIRUXQDYDLODELOLW\RUGLVFRQWLQXDQFHRIQHWZRUNFRYHUDJHLQDVSHFLÀFDUHDRUUHJLRQDQ\QHWZRUNGRZQWLPHRUSHUPDQHQWVHUYLFHVKXWGRZQ )XOOSRZHUXSWRDWOHDVWƒ&ƒ)IRUSRZHUGHUDWLQJLQIRUPDWLRQUHIHUWRKWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI Connecting CTs to the Revenue Grade and Consumption Meter 6LQJOH3KDVH(QHUJ\+XE,QYHUWHU ZLWK3ULVP7HFKQRORJ\ Grid Single Phase Energy Hub Inverter with Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1) Power Optimizer For North America S440, S500 25 YEAR WARRANTY PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Faster installations with simplified cable management and easy assembly using a single bolt Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Flexible system design for maximum space utilization Compatible with bifacial PV modules Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading * Expected availability in 2022 solaredge.com PO W E R OP T I M I Z E R Power Optimizer For North America S440, S500 S440 S500 Unit INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 Vdc MPPT Operating Range 8 - 60 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1+/-0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 153 x 30 / 5.07 x 6.02 x 1.18 mm / in Weight (including cables) 655 / 1.5 gr / lb Input Connector MC4(2) Input Wire Length 0.1 / 0.32 m / ft Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 / (+) 7.54, (-) 0.32 m / ft Operating Temperature Range(3) -40 to +85 ËšC Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the power optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) For ambient temperature above +70°C / +158°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter Single Phase HD-Wave Three Phase for 208V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 10 18 Maximum String Length (Power Optimizers) 25 50(4) Maximum Nominal Power per String 5700 (6000 with SE7600-US-SE11400-U) 6000 12750 W Maximum Allowed Connected Power per String(5) (Permitted only when the difference in connected power between strings is 1,000W or less) Refer to Footnote 5 One string 7200 15000 W Two strings or more 7800 Parallel Strings of Different Lengths or Orientations Yes (4) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (5) If the inverters rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https://www.solaredge.com/sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (6) It is not allowed to mix S-series and P-series Power Optimizers in new installations © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: July 12, 2022 DS-000018-NA. Subject to change without notice. Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com Design Criteria: Subject: Structural Certification for Installation of Residential Solar re job: Attn.: To Whom It May Concern Observation of the condition of the existing framing system was performed by an audit team of After review of the field observation data, structural capacity calculations were performed in accordance with applicable building codes to determine adequacy of the existing roof framing supporting the proposed panel layout.  Please see full Structural Calculations report for details regarding calculations performed and limits of scope of work and liability.  The design criteria and structural adequacy are summarized below: 02-03-2023 02-03-2023 Sunrun Inc. Caron Marshall Sunrun Inc. ROOF 1: Shingle roofing supported by 2x4 Truss @ 24 in. OC spacing. The roof is sloped at approximately 19 degrees and has a max beam span of 9.4 ft between supports. Roof is adequate to support the imposed loads. Therefore, no structural upgrades are required. Code: 2022 CBC, ASCE 7-16, Ult Wind Speed: 130 mph, Ground Snow: 0 psf, Min Snow Roof: 0 psf 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 595 Market St 73576 Adobe Springs Dr, Palm Desert, CA 92260, USA Attn.: To Whom It May Concern re job: The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Design Criteria: Current Renewables Engineering Inc. Professional Engineer info@currentrenewableseng.com 02-03-2023 Page 1 of 8 02-03-2023 Sunrun Inc. 595 Market St Caron Marshall 73576 Adobe Springs Dr, Palm Desert, CA 92260, USA I certify that the roof structure has sufficient structural capacity for the applied PV loads. Code: 2022 CBC, ASCE 7-16, Live Load: 20 psf Ult Wind Speed: 130 mph Exposure Cat: C Ground Snow: 0 psf Min Snow Roof: N/A 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com Roof Properties: Roof Type = Roof Pitch (deg) = Mean Root Height (ft) = Attachment Trib Width (ft) = Attachment Spacing (ft) = Framing Type = Framing Size = Framing OC Spacing (in.) = Section Thickness, b (in) = Section Depth, d (in) = Section Modulus, Sx (in3) = Deflection Limit D+L (in) = Deflection Limit S or W (in) = Attachments Pattern = Framing Upgrade = Sister Size = Wood Species = Wood Fb (psi) = Wood Fv (psi) = Wood E (psi) = CD (wind) = Cd (snow) = CLS = CM = Ct = CL = Ci = CF = Cfu = Cr = F'b wind (psi) = F'b snow (psi) = F'v wind (psi) = F'v snow (psi) = M allowable wind (lb-ft) = M allowable snow (lb-ft) = V allowable wind (lbs) = V allowable snow (lbs) = E' (psi) = Moment of Inertia, lx (in ) = Unsupported Span (ft) = Upper Chord Length (ft) = Page 2 of 8 Shingle 19.0 13.0 2.75 6.0 Truss 2x4 24.0 1.5 3.5 3.062 5.359 9.4 3.8 2.533 Fully Staggered No NA DF 900.0 180.0 1600000.0 1.6 1.15 1.0 1.0 1.5 1.0 1.15 2484.0 1785.37 288.0 207.0 633.94 455.64 1008.0 724.5 Roof 1 1600000.0 19.0 Caron Marshall 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com Load Calculation: Dead Load Calculations: Panels Dead Load (psf) = Roofing Weight (psf) = Decking Weight (psf) = Framing Weight (psf) = Misc. Additional Weight (psf) = Existing Dead Load (psf) = Total Dead Load (psf) = Wind Load Calculations: Ultimate Wind Speed (mph) = Directionality Facto r, kd = Topographic Factor, kzt = Velocity Press Exp Factor, kz = Velocity Pressure, qz (psf) = External Pressure Up, GCp_1 = External Pressure Up, GCp_2 = External Pressure Up, GCp_3 = External Pressure Down, GCp = Design Pressure Up, p_1 (psf) = Design Pressure Up, p_2 (psf) = Design Pressure Up, p_3 (psf) = Design Pressure Down, p (psf) = Snow Load Calculations: Ground Snow Load, pg (psf) = Min Flat Snow, pf_min (psf) = Sloped Snow, ps_min (psf) = Snow Importance Factor, Ic = Exposure Factor, Ce = Thermal Factor, Ct = Flat Roof Snow, pf (psf) = Slope Factor, Cs = Sloped Roof Snow, ps (psf) = Page 3 of 8 3.0 3.0 2.0 0.602 1.0 6.602 9.602 130.0 0.85 1.0 0.849 31.217 -2.0 -2.569 -3.058 0.465 -43.08 -55.343 -65.872 16.0 Roof 1 0.0 0.0 0.0 1.0 0.9 1.1 0.0 1.0 0.0 Caron Marshall 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com Lag Screw Checks: Ref. Withdrawal Value, W (lb/in) = (Cm = Ct = Ceg = 1.0) CD = Adjusted Withdrawal Value, W' (lb/in) = Lag Penetration, p (in.) = Allowable Withdrawal Force, W'p (lbs) = Applied Uplift Force (lbs) = Uplift DCR = Ref. Lateral Value, Z (lbs) = (Cm = Ct = CΔ = Ceg = 1.0) CD = Adjusted Lateral Value, Z' (lbs) = Applied Lateral Force (lbs) = Angle of Resultant Force, α (deg) = Adjusted Interaction Lateral Value, Z'α (lbs) = Lateral DCR = Page 4 of 8 Roof 1 266.0 0.9 243.0 16.116 1.524 1056.039 0.015 266.0 1.6 425.6 2.5 1064.0 -340.789 0.32 Caron Marshall 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com Roof Framing Checks: LC1: D+S Force Checks: Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC2: D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC3: D+0.75(S+0.6W) Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC4: 0.6D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = Page 5 of 8 Caron Marshall 170.0 108.0 456.0 724.0 0.372 0.149 Roof 1 340.0 216.0 634.0 1008.0 0.536 0.214 297.0 188.0 634.0 1008.0 0.468 0.187 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com 387.0 245.0 634.0 1008.0 0.61 0.243 LC2: S LC3: W (Down) Deflection Checks (Service Level): LC1: D+L LC4: W (Up) Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Page 6 of 8 0.869 3.8 0.229 0.0 2.533 0.0 0.147 2.533 0.058 0.396 2.533 0.156 Caron Marshall 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com (Existing W + Additional W)/(Existing W) = Weight Increase: Existing Weight: Total Additional PV Weight (lbs) = Seismic Check: The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Wall Weight (psf) = Tributary Wall Area (ft2) = Total Wall Weight (lbs) = Roof Weight (psf) = Roof Area (ft2) = Total Roof Weight (lbs) = Total Existing Weight (lbs) = Page 7 of 8 17.0 1350.0 22950.0 6.602 4250.0 28056.64 51006.64 653.4 1.013 Caron Marshall 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com Limits of Scope of Work and Liability: Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection, and assumed to have appropriate permits. The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. Page 8 of 8 Caron Marshall 1760 Chicago Ave Suite J13, Riverside, CA 92507 (951) 405-1733info@currentrenewableseng.com