HomeMy WebLinkAbout2024-08-20 PC Regular Meeting Agenda Packet
PLANNING COMMISSION
CITY OF PALM DESERT
MEETING AGENDA
Tuesday, August 20, 2024
6:00 p.m.
Council Chamber, City Hall
73-510 Fred Waring Drive
Palm Desert, California
Pursuant to Assembly Bill 2449, this meeting will be conducted as a hybrid meeting and there will be
in-person access to this location.
To participate via Zoom, use the following link: https://palmdesert.zoom.us/j/84739707419 or
call (213) 338-8477, Zoom Meeting ID: 847 3970 7419
•
Written public comment may also be submitted to PlanningCommission@palmdesert.gov. E-
mails received by 3:00 p.m. prior to the meeting will be distributed to the Commission. Any
correspondence received during or after the meeting will be distributed to the Commission as
soon as practicable and retained for the official record. Emails will not be read aloud except
as an ADA accommodation.
•
Pages
1.CALL TO ORDER
2.ROLL CALL
3.PLEDGE OF ALLEGIANCE
4.NONAGENDA PUBLIC COMMENTS
This time has been set aside for the public to address the Planning Commission
on issues that are not on the agenda for up to three minutes. Speakers may
utilize one of the three options listed on the first page of the agenda. Because
the Brown Act does not allow the Planning Commission to act on items not listed
on the agenda, members may briefly respond or refer the matter to staff for a
report and recommendation at a future meeting.
5.CONSENT CALENDAR
All matters listed on the Consent Calendar are considered routine and may be
approved by one motion. The public may comment on any items on the Consent
Agenda within the three-minute time limit. Individual items may be removed by
the Planning Commission for a separate discussion.
RECOMMENDATION:
To approve the consent calendar as presented.
5.a APPROVAL OF MINUTES 5
RECOMMENDATION:
Approve the Minutes of July 19, 2024.
6.CONSENT ITEMS HELD OVER
7.ACTION CALENDAR
The public may comment on individual Action Items within the three-minute time
limit. Speakers may utilize one of the three options listed on the first page of the
agenda.
None.
8.PUBLIC HEARINGS
Anyone who challenges any hearing matter in court may be limited to raising
only those issues he or she raised at the public hearing described herein, or in
written correspondence delivered to the Planning Commission at, or prior to, the
public hearing. Remarks shall be limited to a maximum of three minutes unless
the Planning Commission authorizes additional time.
8.a CONSIDER ADOPTING A NOTICE OF EXEMPTION AND APPROVING A
CONDITIONAL USE PERMIT FOR AN OUTDOOR PATIO FOR DINING
PURPOSES FOR AN EXISTING RESTAURANT AT 72990 EL PASEO,
SUITE 3
11
RECOMMENDATION:
Adopt Planning Commission Resolution No. 2875 entitled, “A RESOLUTION
OF THE PLANNING COMMISSION OF THE CITY OF PALM DESERT,
CALIFORNIA, ADOPTING A NOTICE OF EXEMPTION PURSUANT TO
THE STATE OF CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA)
AND APPROVING A CONDITIONAL USE PERMIT (CUP) FOR AN
OUTDOOR PATIO FOR DINING PURPOSES FOR AN EXISTING
RESTAURANT AT 72990 EL PASEO, SUITE 3.”
Planning Commission Meeting
2
8.b CONSIDERATION TO ADOPT A MITIGATED NEGATIVE DECLARATION
AND APPROVE A CONDITIONAL USE PERMIT AND PRECISE PLAN
FOR THE LIVING DESERT ZOO AND GARDENS EXPANSION PROJECT
53
RECOMMENDATION:
Adopt Resolution No. 2877 entitled, “A RESOLUTION OF THE PLANNING
COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA,
ADOPTING A MITIGATED NEGATIVE DECLARATION (CEQA)
PURSUANT TO THE CALIFORNIA ENVIRONMENTAL QUALITY ACT
AND APPROVING A CONDITIONAL USE PERMIT AND PRECISE PLAN
FOR THE LIVING DESERT ZOO AND GARDENS EXPANSION PROJECT
LOCATED AT 47900 PORTOLA AVENUE (ASSESSOR’S PARCEL
NUMBER 630-250-045 & 625-300-052).”
8.c CONSIDERATION TO RECOMMEND CITY COUNCIL APPROVE A
PRECISE PLAN AMENDMENT FOR A 1,103 SQUARE FOOT
GUESTHOUSE AT 72240 UPPER WAY WEST
281
RECOMMENDATION:
Adopt Resolution No. 2879 entitled, “A RESOLUTION OF THE PLANNING
COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA,
CONSIDERING A RECOMMENDATION TO THE CITY COUNCIL FOR
THE ADOPTION OF A NOTICE OF EXEMPTION IN ACCORDANCE WITH
THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA), AND
APPROVAL OF A HILLSIDE DEVELOPMENT PLAN TO CONSTRUCT A
1,103-SQUARE-FOOT GUESTHOUSE ON A PROPERTY LOCATED AT
72240 UPPER WAY WEST.”
9.INFORMATIONAL REPORTS & COMMENTS
9.a SUMMARY OF CITY COUNCIL ACTIONS
9.b COMMITTEE MEETING UPDATES
9.b.1 Cultural Arts Committee
9.b.2 Parks and Recreation Committee
9.c PLANNING COMMISSIONERS
9.d CITY STAFF
9.e ATTENDANCE REPORT 327
10.ADJOURNMENT
The next Regular Meeting will be held on September 3, 2024, at 6:00 p.m.
Planning Commission Meeting
3
11.PUBLIC NOTICES
Agenda Related Materials: Pursuant to Government Code §54957.5(b)(2) the
designated office for inspection of records in connection with this meeting is the
Office of the City Clerk, Palm Desert Civic Center, 73-510 Fred Waring Drive,
Palm Desert. Staff reports for all agenda items considered in open session, and
documents provided to a majority of the legislative bodies are available for
public inspection at City Hall and on the City’s website at www.palmdesert.gov.
Americans with Disabilities Act: It is the intention of the City of Palm Desert to
comply with the Americans with Disabilities Act (ADA) in all respects. If, as an
attendee or a participant at this meeting, or in meetings on a regular basis, you
will need special assistance beyond what is normally provided, the City will
attempt to accommodate you in every reasonable manner. Please contact the
Office of the City Clerk, (760) 346-0611, at least 48 hours prior to the meeting to
inform us of your needs and to determine if accommodation is feasible.
Remote Location: Pursuant to traditional Brown Act teleconferencing
requirements, the teleconference location must be listed on the agenda and be
accessible to the public.
Chair Gregory may participate remotely from 58374 Huntington Lodge Rd., Unit
D, Lakeshore, CA 93634.
AFFIDAVIT OF POSTING
I hereby certify under penalty of perjury under the laws of the State of California
that the foregoing agenda for the Planning Commission was posted on the City
Hall bulletin board and City website not less than 72 hours prior to the meeting.
/S/ Niamh M. Ortega, CMC
Assistant City Clerk
Planning Commission Meeting
4
PLANNING COMMISSION
CITY OF PALM DESERT
REGULAR MEETING MINUTES
July 16, 2024, 6:00 p.m.
Present: Commissioner Ron Gregory, Commissioner Lindsay Holt, Chair
Joseph Pradetto
Absent: Commissioner Nancy DeLuna, Commissioner John Greenwood
Staff Present: Director of Development Services Richard Cannone, Principal
Planner Carlos Flores, Principal Planner Nick Melloni, City
Attorney Oscar Verdugo, Recording Secretary Michelle Nance
1. CALL TO ORDER
A Regular Meeting of the Planning Commission was called to order by Chair Pradetto
on Tuesday, July 16, 2024, at 6:00 p.m. in the Council Chamber, City Hall, located at
73-510 Fred Waring Drive, Palm Desert, California.
2. ROLL CALL
3. PLEDGE OF ALLEGIANCE
Chair Pradetto led the Pledge of Allegiance.
4. ELECTION OF PLANNING COMMISSION CHAIRPERSON AND VICE
CHAIRPERSON
Motion by: Chair Pradetto
Seconded by: Commissioner Holt
Elect Commissioner Gregory as Chairperson of the Planning Commission.
Motion Carried (3 to 0)
Motion by: Chair Gregory
Seconded by: Commissioner Pradetto
Elect Commissioner Holt as Vice Chairperson of the Planning Commission.
Motion Carried (3 to 0)
5. NONAGENDA PUBLIC COMMENTS
None.
City of Palm Desert Planning Commission Meeting Minutes
July 19, 2024
1 5
6.CONSENT CALENDAR
Motion by: Commissioner Pradetto
Seconded by: Vice Chair Holt
To approve the consent calendar as presented.
Motion Carried (3 to 0)
6.a APPROVAL OF MINUTES
Approve the Minutes of June 18, 2024.
7.CONSENT ITEMS HELD OVER
None.
8.ACTION CALENDAR
8.a PROVIDE DIRECTION ON CREATION OF LANDSCAPING REGULATION
TASK FORCE
Principal Planner Flores presented the staff report and answered Commissioner
inquiries.
During discussion the following topics were discussed:
•The need for a plant palette that will thrive in local conditions.
•The need for continued maintenance of landscaped areas.
•The importance of shade trees in parking lots.
•Research grants or incentives for applicants to plant more
trees.
Motion by: Commissioner Pradetto
Seconded by: Vice-Chair Holt
Recommend that staff not move forward with a Landscape Regulation Task
Force and continue to work on a Unified Code addressing concerns with
landscaping.
Motion Carried (3 to 0)
City of Palm Desert Planning Commission Meeting Minutes
July 19, 2024
2 6
8.b CONSIDERATION OF A RECOMMENDATION OF APPROVAL TO THE PALM
DESERT CITY COUNCIL FOR A PROPOSED MODIFICATION OF ZONING
ORDINANCE AMENDMENT CASE NUMBER ZOA240002.
Principal Planner Melloni narrated a PowerPoint presentation and answered
Commission inquiries.
Motion by: Commissioner Pradetto
Seconded by: Vice Chair Holt
Adopt Resolution No. 2876 entitled “A RESOLUTION OF THE PLANNING
COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA,
RECOMMENDING APPROVAL OF A ZONING ORDINANCE AMENDMENT TO
AMEND SECTIONS 25.16.030, 25.18.040, 25.28.070, 25.34.120, 25.68.020,
AND 25.99.020 OF PALM DESERT MUNICIPAL CODE TITLE 25, WITH
MODIFICATIONS MADE BY THE CITY COUNCIL, AND MAKING A FINDING
THAT THE ACTION IS EXEMPT FROM FURTHER ENVIRONMENTAL REVIEW
PURSUANT TO THE CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA).”
Motion Carried (3 to 0)
9.PUBLIC HEARINGS
9.a CONSIDER MODIFICATION OF CONDITIONAL USE PERMIT 170033 FOR
THE OPERATION OF A CANNABIS BUSINESS AT 73818 DINAH SHORE
DRIVE
Principal Planner Flores narrated a PowerPoint presentation and answered
Commissioner inquiries.
Chair Gregory opened the Public Hearing.
Corey Tobin, Applicant, thanked the Commission for their time and offered to
answer any questions they may have.
Sam Spinello, Palm Desert resident, spoke in favor of the modification of
Conditional Use Permit 17-0033.
Chair Gregory closed the Public Hearing.
Motion by: Commissioner Pradetto
Seconded by: Vice Chair Holt
Adopt Resolution No. 2870 entitled, “A RESOLUTION OF THE PLANNING
COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, MODIFYING
CONDITIONAL USE PERMIT NO. 17-0033 WHICH ALLOWS THE OPERATION
OF A CANNABIS BUSINESS ON THE PROPERTY LOCATED AT 73818 DINAH
SHORE DRIVE.”
Motion Carried (3 to 0)
City of Palm Desert Planning Commission Meeting Minutes
July 19, 2024
3 7
9.b CONSIDERATION TO ADOPT A MITIGATED NEGATIVE DECLARATION AND
APPROVE A CONDITIONAL USE PERMIT AND PRECISE PLAN FOR THE
LIVING DESERT ZOO AND GARDENS EXPANSION PROJECT
This item was continued to the Planning Commission meeting of August 6, 2024.
9.c CONSIDERATION OF REVOCATION OF CONDITIONAL USE PERMIT NO. 17
0018 FOR THE OPERATION OF A CULTIVATION, MANUFACTURING,
DISTRIBUTION, DELIVERY AND RETAIL CANNABIS BUSINESS LOCATED
AT 42 650 MELANIE PLACE
Principal Planner Melloni narrated a PowerPoint and answered Commissioner
inquiries.
Chair Gregory opened and closed the Public Hearing, there being no one
desiring to speak.
Motion by: Vice-Chair Holt
Seconded by: Commissioner Pradetto
Adopt Resolution No. 2878 entitled, “A RESOLUTION OF THE PLANNING
COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, REVOKING, IN
ITS ENTIRETY, CONDITIONAL USE PERMIT NO. 17-0018 FOR THE
OPERATION OF A CULTIVATION, MANUFACTURING, DISTRIBUTION,
DELIVERY AND RETAIL CANNABIS BUSINESS LOCATED AT 42-650
MELANIE PLACE.”
Motion Carried (3 to 0)
10.INFORMATIONAL REPORTS & COMMENTS
10.a SUMMARY OF CITY COUNCIL ACTIONS
10.b COMMITTEE MEETING UPDATES
10.b.1 Cultural Arts Committee
Vice Chair Holt stated she was unable to attend the recent Cultural Arts
Committee meeting but provided an update on the Committee's agenda
items.
10.b.2 Parks and Recreation Committee
Principal Planner Melloni advised the Commission that the recent Parks
and Recreation Committee meeting was canceled, and the next Regular
Meeting will be August 6, 2024.
10.c PLANNING COMMISSIONERS
None.
City of Palm Desert Planning Commission Meeting Minutes
July 19, 2024
4 8
10.d CITY STAFF
None.
10.e ATTENDANCE REPORT
Deputy Clerk Nance advised of a clerical error to be addressed, but no further
action taken on this item.
11.ADJOURNMENT
The Planning Commission adjourned at 7:01 p.m.
12.PUBLIC NOTICES
_________________________
Michelle Nance, Deputy Clerk II
Recording Secretary
_________________________
Richard Cannone, Director of Development Services
Staff Liaison
City of Palm Desert Planning Commission Meeting Minutes
July 19, 2024
5 9
10
Page 1 of 4
CITY OF PALM DESERT
PLANNING COMMISSION
STAFF REPORT
MEETING DATE: August 20, 2024
PREPARED BY: Carlos Flores, AICP, Principal Planner
SUBJECT: CONSIDER ADOPTING A NOTICE OF EXEMPTION AND APPROVING A
CONDITIONAL USE PERMIT FOR AN OUTDOOR PATIO FOR DINING
PURPOSES FOR AN EXISTING RESTAURANT AT 72990 EL PASEO,
SUITE 3
RECOMMENDATION:
Adopt Planning Commission Resolution No. 2875 entitled, “A RESOLUTION OF THE
PLANNING COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, ADOPTING A
NOTICE OF EXEMPTION PURSUANT TO THE STATE OF CALIFORNIA ENVIRONMENTAL
QUALITY ACT (CEQA) AND APPROVING A CONDITIONAL USE PERMIT (CUP) FOR AN
OUTDOOR PATIO FOR DINING PURPOSES FOR AN EXISTING RESTAURANT AT 72990
EL PASEO, SUITE 3”
BACKGROUND/ANALYSIS:
On May 28, 2024, the City’s Architectural Review Commission (ARC) considered a request by
Charissa Farley-Hay (Applicant), for consideration of a Design Review to approve architecture
and landscaping for an outdoor patio remodel for “Wildest Restaurant” (Restaurant), located at
72990 El Paseo, Suite #3 (Assessor’s Parcel Number: 640170013), within the Palms to Pines
West Shopping Center. The project includes a 2,977 square foot (sf) outdoor permane nt dining
patio with a pergola/trellis, an 8’ x 40’ storage container (Container), block wall, pavers, and
landscaping.
The ARC took the following action on the item: Following discussion, MOTION BY CHAIR
VUKSIC, SECOND BY COMMISSIONER MCAULIFFE, CARRIED 6-0 (VICE CHAIR
MCINTOSH ABSENT); to approve Case No. DR23-0015 with the following conditions:
1. Roll-up door shall be further studied and reviewed by staff regarding its
maintainability or be replaced with swinging metal doors.
2. A pilaster with the same stone cladding on the building shall be added to the
opening at the northeast corner of the patio.
3. Gravel placed in planters adjacent to the parking lot shall match existing parking
lot gravel.
4. Shipping container shall be new or in like-new condition.
On June 18, 2024, the City’s Planning Commission (Commission) considered the same project
request at a public hearing for Conditional Use Permit approval. The Commission discussed the
design of the proposed storage container and after discussion, motioned for the project to be
returned to the ARC to refine the Container with a more elegant appearance; then return to the
11
City of Palm Desert – Planning Commission
CUP23-0015 Wildest Restaurant Outdoor Patio
Page 2 of 4
Commission for further consideration. All other components of the project were found acceptable
with exception to the Container. Complete details for the full project description, analysis, and
findings can be found in the June 18, 2024, PC meeting staff report (Attachment 7).
On July 23, 2024, the Applicant presented a revised set of plans to the ARC for their
consideration. The revised plans presented a new Container design. All other components of
the project remain unchanged.
Following discussion, MOTION BY VICE CHAIR MCINTOSH, SECOND BY COMMISSIONER
MCAULIFFE, CARRIED 6-0 (COMMISSIONER BLAKELEY ABSENT); the ARC approved the
revised Case No. DR23-0015 with the following conditions:
1. A pilaster with the same stone cladding on the building shall be added to the
opening at the northeast corner of the patio.
2. Gravel placed in planters adjacent to the parking lot shall match existing parking
lot gravel.
3. Shipping container shall be new or like-new condition.
Below is a summary of the revised plans.
Project Summary:
The Applicant has submitted a revised design for the Container. The revisions include:
- The Container will be finished with wood panels bolt mounted to the container.
- The wood panels will have a “wood grain” pattern and “Peruvian Teak” color,
emulating the desert color palette of the restaurant.
- The corners of the Container will have a trim finish, primed and painted to match
the rest.
- The Container doors will now be a 6’ x 6’-8” double door, rather than a roll up door.
- The Container will include a tube frame welded to the container, with flat sleet slats
welded to the tubs
The Container will also include a new sign, that qualifies as a secondary sign under Palm Desert
Municipal Code (PDMC) Section 25.56.080(C). The sign proposed is a non -illuminated, steel
plaque sign with the Restaurant logo installed on the south facing elevatio n of the Container.
The sign will be installed at the top of the Container’s elevation and measures 3’-2” in height and
4’-4” in length (13.68 square feet). The top of the sign plaque will be 8’-5 ¼” from the ground
floor, extending 5” above the container and 4’ back on the top of the container. The existing sign
on the south elevation is a 23.4 square foot illuminated building mounted sign. The combined
square footage of the existing sign and the proposed sign is 37.08 square feet, which is under
the maximum 50 square feet allowed.
All other components of the project remain unchanged.
12
City of Palm Desert – Planning Commission
CUP23-0015 Wildest Restaurant Outdoor Patio
Page 3 of 4
Public Notice:
Public Notification
Public noticing was conducted for this Planning Commission meeting per the requirements of
the Palm Desert Municipal Code (PDMC). A public hearing notice was published a minimum of
10 days before the hearing date on Friday, August 9, 2024, in The Desert Su n newspaper.
Notices were mailed to all property owners within 300 feet of the project site. No comments
have been received to date.
Environmental Assessment/Environmental Review:
The application has complied with the requirements of the “City of Palm Desert Procedure for
Implementation of CEQA” Resolution No. 2024-035, in that the Planning Commission finds that
the Project is exempt from CEQA per Section 15301 of the State CEQA guidelines as the Project
is an Article 19, Section 15301 Existing Facilities (Class 1) project. Class 1 consists of the
operation, repair, maintenance, permitting, leasing, licensing, or minor alteration of existing
public or private structures, facilities, mechanical equipment, or topographical features, involving
negligible or no expansion of existing or former use. The expansion is in an area where all public
services and facilities are available to allow for maximum development permissible in the
General Plan and in an area that is not environmentally sensitive.
Additionally, the Project is not subject to any of the exceptions for categorical exemptions
identified in CEQA Guidelines Section 15300.2:
1) The Project qualifies as a Class 1 exemption, which is not listed as one of the classes
under 15300.2 (A). The Project is not located on a site where it may have an adverse impact on
an environmental resource of hazardous or critical concern where designated, precisely
mapped, and officially adopted pursuant to law by federal, state, or local agencies. The Project
site will not impact designated environmental or biological resources as it is not located within a
conservation area as identified by the (MSHCP).
2) The Project will not have a cumulative impact on the environment. There are no other or
previous projects that have occurred in succession in the same place, of the same type, to
include a cumulative impact.
3) There are no unusual circumstances identified in relation to the proposed use or Project
site which would result in a significant impact on the environment. The Project site is not located
within a flood zone per the latest FEMA Flood Zone Maps. The Project site is located within a
Very High area per Fire Hazard Severity Zone maps depicted in Figure 8.5 on Page 119 of the
General Plan. The nearest fire station is located less than ½ mile east of the Project site. The
Project site is not identified within an Alquist -Priolo Fault Zone per the latest maps on file with
the California Department of Conservation; the nearest fault zone is the San Andreas Fa ult
located north of the Palm Desert City Limits.
4) The Project site is located within 300 feet of Highway 74, which is a State Scenic Highway.
The project, as condition, will not result in any damage to this scenic resource. The project is
proposing an outdoor dining patio with construction limited to an attached trellis, walls, storage,
13
City of Palm Desert – Planning Commission
CUP23-0015 Wildest Restaurant Outdoor Patio
Page 4 of 4
and landscaping. The project meets all development standards of the underlying zone and is not
proposing a structure height above existing buildings. This proposal is f or use of an outdoor area
for dining purposes and does not propose any construction that would cause damage to Highway
74. The applicant utilizes landscaping throughout the project site to beautify the area.
5) Hazardous Waste Site: The Project site has not been identified as a hazardous waste site
per maps and databases provided by the California Department of Toxic Substances Control
(DTSC).
6) The Project site does not contain any structure or title that would designate it as a
historical resource. Therefore, the Project will not cause a substantial adverse change in the
significance of a historical resource.
Findings of Approval:
Findings of Approval can be found in draft Resolution No. 2875 (Attachment 1)
ATTACHMENTS:
1. Draft Resolution No. 2875
2. PC Notice of Action
3. Architectural Review Commission Notice of Actions
4. Project Plans
5. Public Hearing Notice
6. Draft Notice of Exemption
7. June 18, 2024, PC Staff report
14
PLANNING COMMISSION RESOLUTION NO. 2875
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF PALM
DESERT, CALIFORNIA, ADOPTING A NOTICE OF EXEMPTION
PURSUANT TO THE STATE OF CALIFORNIA ENVIRONMENTAL QUALITY
ACT (CEQA) AND APPROVING A CONDITIONAL USE PERMIT (CUP) FOR
AN OUTDOOR PATIO FOR DINING PURPOSES FOR AN EXISTING
RESTAURANT AT 72990 EL PASEO, SUITE 3
CASE NO. CUP23-0015
WHEREAS, Charissa Farley-Hay (“Applicant”), submitted a CUP application to
construct an outdoor patio for dining purposes at an existing restaurant (Wildest Restaurant)
at 72990 El Paseo, Suite 3 (APN 640-170-013) within the Palms to Pines West Shopping
Center (“Project”); and
WHEREAS, the Project site is currently within the Planned Commercial (PC-3), Scenic
Preservation zoning designation and is designated Regional Retail by the Palm Desert
General Plan; and
WHEREAS, the proposed Project conforms to the General Plan land use designation
of Regional Retail and development standards listed in the City’s Zoning Ordinance for the
PC-3 zoning district; and
WHEREAS, under Section 21067 of the Public Resources Code, Section 15367 of the
State CEQA Guidelines (Cal. Code Regs., tit. 14, § 15000 et seq.), and the City of Palm
Desert’s (“City’s”) Local CEQA Guidelines, the City is the lead agency for the Project; and
WHEREAS, the Project has complied with the requirements of the "2024 Local
Guidelines for Implementing the California Environmental Quality Act for the City Palm
Desert” Resolution No. 2024-035, in that the Director of Development Services has
determined that the Project will not have a foreseeable significant impact on the environment
and that the Project is eligible for an exemption pursuant to Article 19, Section 15301 Existing
Facilities (Class 1); therefore, no further environmental review is necessary at this time; and
WHEREAS, the Architectural Review Commission of the City of Palm Desert,
California, did on the 28th day of May 2024, provide Design Review approval of said project,
subject to conditions of approval; and
WHEREAS, the Planning Commission of the City of Palm Desert, California, did on
the 18th day of June 2024, hold a duly noticed public hearing to consider the request by the
Applicant for approval of the above-noted Project request, continued the project to a date
uncertain, and directed the Project to be returned to the Architectural Review Commission to
refine the storage container with a more elegant appearance and bring back to Planning
Commission for further consideration; and
WHEREAS, the Architectural Review Commission of the City of Palm Desert,
California, did on the 23rd day of July 2024, provide Design Review approval of said project,
subject to conditions of approval which have been included in this Resolution; and
15
PLANNING COMMISSION RESOLUTION NO. 2875
2
WHEREAS, the Planning Commission of the City of Palm Desert, California, did on
the 20th day of August 2024, hold a duly noticed public hearing to consider the request by the
Applicant for approval of the above-noted Project request; and
WHEREAS, at the said public hearing, upon hearing and considering all testimony and
arguments, if any, of all interested persons desiring to be heard, the Planning Commission
did find the following facts and reasons, which are outlined in the staff report, exist to justify
approval of said request:
NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of
Palm Desert, California, as follows:
SECTION 1. Recitals. The Planning Commission hereby finds that the foregoing
recitals are true and correct and are incorporated herein as substantive findings of this
Resolution.
SECTION 2. Findings on Conditional Use Permit. Under PDMC Section 25.72.050(F),
the findings for the CUP are the following:
1. The proposed location of the conditional use is in accord with the objectives of this
title and the purpose of the district in which the site is located.
The location of the conditional use is an outdoor expansion area for an existing
suite and building that was constructed to meet all applicable standards of the PC-
3 district. All objectives of the title and purposes of the PC-3 district are being met
with this CUP as there are no changes to the building itself. The PC-3 district allows
for restaurant uses, as is proposed in this project. The project, as conditioned, is
designed to meet the purpose of the district in which the site is located.
2. The proposed location of the conditional use and the conditions under which it
would be operated or maintained will not be detrimental to the public health, safety,
or welfare, or be materially injurious to properties or improvements in the vicinity.
The Project is located in the exterior of an existing commercial building with
sufficient parking. Although the project is removing some parking spaces, the
applicant has provided documentation on shared parking throughout the site to
make up for the loss of parking stalls. The site has been previously designed to
meet access, utilities, setbacks, lot coverage, building height, land use, and
parking requirements for nonresidential uses. The proposed Project does not pose
a conflict regarding land use and can be conditioned to not be detrimental to the
public health, safety, or welfare, or be materially injurious to properties or
improvements in the vicinity.
3. The proposed conditional use will comply with each of the applicable provisions of
this title, except for approved variances or adjustments.
The location of the conditional use is an exterior area adjacent to an existing suite
that was constructed to meet all applicable standards of the PC-3 district. All
objectives of the title and purposes of the PC-3 district are being met with this CUP
as there are no changes to the building or site itself. The PC-3 district allows for
16
PLANNING COMMISSION RESOLUTION NO. 2875
3
restaurant uses, as is proposed in this project. The project, as conditioned, is
designed to meet the purpose of the district in which the site is located.
4. The proposed conditional use complies with the goals, objectives, and policies of
the City’s General Plan
The subject property is designated Regional Retail per the General Plan Land Use
Element. The Regional Retail land use designation allows restaurant and
commercial uses and its intent and purpose is to “provide large-format retail
development along with associated restaurant and commercial service activity”.
The proposed use is the expansion of an existing and operational restaurant. The
property does not have any applicable specific plans or any other City
regulations/standards. Specifically, the following General Plan Goals and policies
are being met:
Land Use Goal 8 – Economic Development. A diverse, growing, and resilient local
economy.
Land Use Policy 3.14 – The project would continue to provide access for residents
to an existing restaurant and enhance the restaurant.
Land Use Policy 4.3 – The project would allow for a wide variety of uses to locate
in a Regional Retail district.
SECTION 3. CEQA. The application has complied with the requirements of the “2024
Local Guidelines for Implementing the California Environmental Quality Act for the City Palm
Desert”” Resolution No. 2024-035, in that the Planning Commission finds that the Project is
exempt from CEQA per Section 15301 of the State CEQA guidelines as the Project is an
Article 19, Section 15301 Existing Facilities (Class 1) project. Class 1 consists of the
operation, repair, maintenance, permitting, leasing, licensing, or minor alteration of existing
public or private structures, facilities, mechanical equipment, or topographical features,
involving negligible or no expansion of existing or f ormer use. The expansion is in an area
where all public services and facilities are available to allow for maximum development
permissible in the General Plan and in an area that is not environmentally sensitive.
Additionally, the Project is not subject to any of the exceptions for categorical exemptions
identified in CEQA Guidelines Section 15300.2:
1) The Project qualifies as a Class 1 exemption, which is not listed as one of the classes
under 15300.2 (A). The Project is not located on a site where it may have an adverse
impact on an environmental resource of hazardous or critical concern where
designated, precisely mapped, and officially adopted pursuant to law by federal, state,
or local agencies. The Project site will not impact designated environmental or
biological resources as it is not located within a conservation area as identified by the
(MSHCP).
2) The Project will not have a cumulative impact on the environment. There are no other
or previous projects that have occurred in succession in the same place, of the same
type, to include a cumulative impact.
17
PLANNING COMMISSION RESOLUTION NO. 2875
4
3) There are no unusual circumstances identified in relation to the proposed use or
Project site which would result in a significant impact on the environment. The Project
site is not located within a flood zone per the latest FEMA Flood Zone Maps. The
Project site is located within a Very High area per Fire Hazard Severity Zone maps
depicted in Figure 8.5 on Page 119 of the General Plan. The nearest fire station is
located less than ½ mile east of the Project site. The Project site is not identified within
an Alquist-Priolo Fault Zone per the latest maps on file with the California Department
of Conservation; the nearest fault zone is the San Andreas Fault located north of the
Palm Desert City Limits.
4) The Project site is located within 300 feet of Highway 74, which is a State Scenic
Highway. The project, as condition, will not result in any damage to this scenic
resource. The project is proposing an outdoor dining patio with construction limited to
an attached trellis, walls, storage, and landscaping. The project meets all
development standards of the underlying zone and is not proposing a structure height
above existing buildings. This proposal is for use of an outdoor area for dining
purposes and does not propose any construction that would cause damage to
Highway 74. The applicant utilizes landscaping throughout the project site to beautify
the area.
5) Hazardous Waste Site: The Project site has not been identified as a hazardous waste
site per maps and databases provided by the California Department of Toxic
Substances Control (DTSC).
6) The Project site does not contain any structure or title that would designate it as a
historical resource. Therefore, the Project will not cause a substantial adverse change
in the significance of a historical resource.
SECTION 4. Project Approval. The Planning Commission hereby recommends
approval of CUP23-0015.
SECTION 5. Custodian of Records. The documents and materials that constitute the
record of proceedings on which these findings are based are located at the City’s office at
73510 Fred Waring Drive, Palm Desert, CA 92260. Richard D. Cannone, AICP, the Secretary
to the Palm Desert Planning Commission, is the custodian of the record of proceedings.
SECTION 6. Execution of Resolution. The Chairperson of the Planning Commission
signs this Resolution, and the Secretary to the Commission shall attest and certify to the
passage and adoption thereof.
NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of
Palm Desert, California, as follows:
1. That the above recitations are true and correct and constitute the findings for
approval of the Planning Commission in this case.
2. That the Planning Commission does hereby approve Case No. CUP23-0015,
pursuant to the conditions of approval in Exhibit A and the statement of operations
in Exhibit B.
18
PLANNING COMMISSION RESOLUTION NO. 2875
5
ADOPTED ON August 20, 2024.
RON GREGORY
CHAIRPERSON
ATTEST:
RICHARD D. CANNONE, AICP
SECRETARY
I, Richard D. Cannone, AICP, Secretary of the City of Palm Desert Palm Commission,
hereby certify that Resolution No. 2875 is a full, true, and correct copy, and was duly adopted
at a regular meeting of the Planning Commission of the City of Palm Desert on August 20,
2024, by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
RECUSED:
IN WITNESS WHEREOF, I have hereunto set my hand and affixed the official seal of the City
of Palm Desert, California, on August ___, 2024.
RICHARD D. CANNONE, AICP
SECRETARY
19
PLANNING COMMISSION RESOLUTION NO. 2875
6
EXHIBIT A
CONDITIONS OF APPROVAL
CASE NO. CUP23-0015
PLANNING DIVISION:
1. The development of the property shall conform substantially with the approved plans and
exhibits on file with the Development Services Department, except as modified by the
following conditions. Any variation from the approved plans must be reviewed and
approved by the Planning Division prior to building permit issuance and may require
review and approval by the ARC, Planning Commission, and/or City Council.
2. The Applicant agrees that in the event of any administrative, legal, or equitable action
instituted by a third party challenging the validity of any of the procedures leading to the
adoption of these Project Approvals for the Project, or the Project Approvals themselves,
the Developer and City each shall have the right, in their sole discretion, to elect whether
or not to defend such action. The Developer, at its sole expense, shall defend, indemnify,
and hold harmless the City (including its agents, officers, and employees) from any such
action, claim, or proceeding with counsel chosen by the City, subject to the Developer’s
approval of counsel, which shall not be unreasonably denied, and at the Developer’s sole
expense. If the City is aware of such an action or proceeding, it shall promptly notify the
Developer and cooperate in the defense. The Developer, upon such notification, shall
deposit with City sufficient funds in the judgment of the City Finance Director to cover the
expense of defending such action without any offset or claim against said deposit to
assure that the City expends no City funds. If both Parties elect to defend, the Parties
hereby agree to affirmatively cooperate in defending said action and to execute a joint
defense and confidentiality agreement in order to share and protect the information under
the joint defense privilege recognized under applicable law. As part of the cooperation in
defending an action, City and Developer shall coordinate their defense in order to make
the most efficient use of legal counsel and to share and protect information. Developer
and City shall each have sole discretion to terminate its defense at any time. The City
shall not settle any third-party litigation of Project approvals without the Developer’s
consent, which consent shall not be unreasonably withheld, conditioned, or delayed
unless the Developer materially breaches this indemnification requirement.
3. The development of the property described herein shall be subject to the restrictions and
limitations set forth herein, which are in addition to the approved development standards
listed in the Palm Desert Municipal Code (PDMC), and state and federal statutes now in
force, or which hereafter may be in force.
4. The CUP shall expire if construction of the said Project shall not commence within 24
months from the date of final approval unless an extension of time is granted by the Palm
Desert Planning Commission; otherwise, said approval shall become null, void, and of
no effect whatsoever.
5. All construction documentation shall be coordinated for consistency, including, but not
limited to, architectural, structural, mechanical, electrical, plumbing, landscape and
20
PLANNING COMMISSION RESOLUTION NO. 2875
7
irrigation, grading, and street improvement plans. All such plans shall be consistent with
the approved entitlement plans on file with the Development Services Department.
6. The approved CUP shall only be modified with written City approval per PDMC Chapter
25.72.050. Any proposed changes to this CUP will require an amendment to the
application, which may require review and approval by the ARC, Planning Commission,
and/or City Council.
7. This approval authorizes the operation of a 2,977 square foot outdoor permanent dining
patio expansion of the existing “Wildest” restaurant, which includes a pergola/trellis,
storage container, fireplace, heaters, lighting, pavers, wall, and landscaping.
8. The use shall operate as an expansion of the adjoining restaurant, consistent with the
approved Statement of Operations on file with the Development Services Department
and attached as Exhibit B. Any amendments to the proposed hours of operation are
subject to the discretion of the Zoning Administrator and shall require a modification of
the approved conditions. After-hours use of the facility, other than for routine clean-up
maintenance, and deliveries will not be permitted.
9. The Applicant shall execute a written acknowledgment to the Planning Division stating
acceptance of and compliance with all the Conditions of Approval of Resolution No. 2875
for CUP23-0015 and that the plans submitted are in compliance with the Conditions of
Approval. No modifications shall be made to said plans without written approval from the
appropriate decision-making body.
10. Prior to the issuance of a building permit for the construction of any use or structure
contemplated by this approval, the Applicant shall first obtain permits and or clearance
from the following agencies:
Coachella Valley Water District (CVWD)
Public Works Department
Fire Department
Building and Safety Division
California Department of Alcoholic Beverage Control
Riverside County Department of Health
Evidence of said permit or clearance from the above agencies shall be presented to the
Building and Safety Division at the time of issuance of a building permit for the use
contemplated herewith.
11. A copy of the herein-listed Conditions of Approval shall be included in the construction
documentation package for the Project, which shall be continuously maintained on-site
during Project construction.
12. Failure to comply with any of these conditions will result in the revocation of this permit
subject to PDMC 25.60.
21
PLANNING COMMISSION RESOLUTION NO. 2875
8
13. The Applicant shall comply with all conditions of approval provided by the City’s
Architectural Review Commission on May 28, 2024, as follows:
A. Roll up door shall be further studied and reviewed by staff regarding its
maintainability or be replaced with swinging metal doors.
B. A pilaster with the same stone cladding on the building shall be added to
the opening at the northeast corner of the patio.
C. Gravel placed in planters adjacent to the parking lot shall match existin g
parking lot gravel.
D. Shipping container shall be new or like-new condition.
14. The Applicant shall comply with PDMC Chapter 9.24 for Noise Control Requirements.
No loud or disturbing music, sound, or noise shall be detectable from the exterior of the
premises.
15. The storage container shall remain consistent with the use and design as presented in
this project approval. This includes ensuring the material wrapped around the container
remains in good condition and the use remains for storage purposes and not for
restaurant operational purposes (such as serving drinks). Any change of design or use
shall be submitted to the City’s Development Services department and may require
amendment of this Conditional Use Permit.
16. The Applicant shall remove litter from the premises, and adjacent public sidewalks and
parking lots daily, and shall keep the areas swept weekly to prevent debris buildup. Trash
cans shall be added, and "No Littering" signs shall be posted on the premises.
17. The Applicant shall not permit any loitering on the premises or on property adjacent to
the premises.
18. The requirements of PDMC Chapter 8.36 regarding smoking shall be complied with at all
times.
19. The Applicant shall submit a landscape plan application for the newly proposed
landscaping on the exterior of the project. The proposed landscaping shall be consistent
with the preliminary landscape plan provided as part of this Project.
20. The design of the proposed retaining wall is subject to review by the City’s Development
Services Department and may require a stucco finish.
21. All permanent and temporary exterior signage shall comply with PDMC 25.56.
22. The Applicant shall provide payment for filing fees for the Notice of Exemption within five
(5) days of project approval.
LAND DEVELOPMENT
23. The following plans, studies, and exhibits are hereby referenced: Preliminary Grading
Plan Lot 5 of Parcel Map 14710 Wildest Restaurant Patio; prepared by Egan Civil, Inc.;
dated April 12, 2024.
22
PLANNING COMMISSION RESOLUTION NO. 2875
9
24. It is understood that the conceptual exhibits correctly show all existing easements,
traveled ways, and drainage courses with appropriate Qs, and that major modification
with the final plans and reports may require the applicant to process a revised site plan
through Planning Commission as directed by the City Engineer.
25. It is assumed that easements shown on the preliminary grading plan shown correctly and
include all the easements that encumber the subject property. A current preliminary title
report for the site will be required to be submitted during technical pl an review.
26. Prior to building permit, the applicant shall secure approval from all, if any, easement
holders for all grading and improvements, which are proposed over the respective
easement, including those shown on Instrument No. 08-195654, or provide evidence that
the easement has been relocated, quitclaimed, vacated, abandoned, easement holder
cannot be found, or is otherwise of no effect. Should such approvals or alternate actions
regarding the easements not be provided and approved by the City, the applicant may
be required to amend or revise the proposed site configuration as may be necessary.
27. Prior to building permit, the applicant shall submit a final grading plan that includes
grading of parking lot, proposed site and patio, and proposed drainage. The grading
plans shall be submitted as part of the building plan set and be in conformance with the
preliminary grading exhibit. The City Engineer shall approve the final grading as part of
the building permit review.
28. Prior to final building permit inspection, the applicant shall schedule an inspection from
the City’s Engineering department. The inspection shall verify compliance of the built
improvements with the final grading plans requested on these conditions of approval.
COACHELLA VALLEY WATER DISTRICT
29. The Applicant will need to send applications to the Coachella Valley Water District
(CVWD) for re-evaluation of the grease interceptor sizing and capacity charges.
Application(s) include the Cost Notification Application, Source Control application, and
a copy of plumbing and seating plans.
RIVERSIDE COUNTY FIRE DEPARTMANT
30. Fire Department Building Construction Plan Review – Submittal of construction plans to
the Fire Department will be required. Final fire and life safety conditions will be addressed
when the Fire Department reviews the plans. These conditions will be based on California
Fire Code, California Building Code (CBC), and related codes/standards adopted at the
time of construction plan submittal. Reference CFC as amended.
31. Fire Sprinkler System – All new commercial areas of the building and structures shall be
evaluate for the extension of the existing fire sprinkler system. Reference CFC as
amended.
23
PLANNING COMMISSION RESOLUTION NO. 2875
10
32. Fire Alarm and Detection System – A water flow monitoring system and/or fire alarm
system may be required to be extended into the new areas as determined at time of
building construction plan review. Reference CFC as amended.
END OF CONDITIONS OF APPROVAL
24
PLANNING COMMISSION RESOLUTION NO. 2875
11
EXHIBIT B
Statement of Operations
25
PLANNING COMMISSION RESOLUTION NO. 2875
12
26
27
28
CITY OF PALM DESERT
73-510 FRED WARING DRIVE
PALM DESERT, CALIFORNIA 92260-2578
TEL: 760-346-0611
PLANNING@PALMDESERT.GOV
ARCHITECTURAL REVIEW COMMISSION
NOTICE OF ACTION
June 4, 2024
Wildest Restaurant and Bar
Ms. Charissa Farley – Hay
PO Box 14450
Palm Desert, CA 92255
Subject: Consideration to approve a Design Review for the architecture and
landscaping associated with an outdoor patio remodel for Wildest Restaurant at 72990
El Paseo, Suite #3
The Architectural Review Commission of the City of Palm Desert considered your request
and took the following action at its meeting of May 28, 2024:
Following discussion, MOTION BY CHAIR VUKSIC, SECOND BY COMMISSIONER
MCAULIFFE, CARRIED 6-0 (VICE CHAIR MCINTOSH ABSENT); to approve Case
No. DR23-0015 with the following conditions:
1. Roll up door shall be further studied and reviewed by staff regarding its
maintainability or be replaced with swinging metal doors.
2. A pilaster with the same stone cladding on the building shall be added to the
opening at the northeast corner of the patio.
3. Gravel placed in planters adjacent to the parking lot shall match existing parking
lot gravel.
4. Shipping container shall be new or like-new condition.
Pursuant to Palm Desert Municipal Code Section 25.60.080, any appeal of the above action may
be made in writing to the City Clerk, City of Palm Desert, within 15 days of the date of the decision.
If you have any questions, please contact Principal Planner, Carlos Flores, at (760) 776-6478
or cflores@palmdesert.gov.
Sincerely,
CARLOS FLORES, SECRETARY
ARCHITECTURAL REVIEW COMMISSION
cc: File
29
CITY OF PALM DESERT
73-510 FRED WARING DRIVE
PALM DESERT, CALIFORNIA 92260-2578
TEL: 760-346-0611
PLANNING@PALMDESERT.GOV
ARCHITECTURAL REVIEW COMMISSION
NOTICE OF ACTION
August 12, 2024
Wildest Restaurant and Bar
Ms. Charissa Farley – Hay
PO Box 14450
Palm Desert, CA 92255
Subject: Consideration to approve a revised Design Review for the architecture
associated with an outdoor patio remodel for Wildest Restaurant at 72990 El Paseo,
Suite #3
The Architectural Review Commission of the City of Palm Desert considered your request
and took the following action at its meeting of July 23, 2024:
Following discussion, MOTION BY VICE CHAIR MCINTOSH, SECOND BY
COMMISSIONER MCAULIFFE, CARRIED 6-0 (COMMISSIONER BLAKELEY
ABSENT); to approve Case No. DR23-0015 with the following conditions:
1. A pilaster with the same stone cladding on the building shall be added to the
opening at the northeast corner of the patio.
2. Gravel placed in planters adjacent to the parking lot shall match existing parking
lot gravel.
3. Shipping container shall be new or like-new condition.
If you have any questions, please contact Principal Planner, Carlos Flores, at (760) 776-6478
or cflores@palmdesert.gov.
Sincerely,
CARLOS FLORES, SECRETARY
ARCHITECTURAL REVIEW COMMISSION
cc: File
30
C I T Y O F P A L M
D E S E R T
73-510 FRED WARING DRIVE
PALM DESERT, CALIFORNIA 92260-2578
TEL: 760-346-0611
INFO@CITYOFPALMDESERT.ORG
CITY OF PALM DESERT
PUBLIC HEARING NOTICE
CASE NO. CUP23-0015
NOTICE IS HEREBY GIVEN THAT A PUBLIC HEARING WILL BE HELD BEFORE THE PLANNING
COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, TO REVIEW A REQUEST BY
CHARISSA FARLEY-HAY TO APPROVE A CONDITIONAL USE PERMIT APPLICATION FOR AN
OUTDOOR PATIO FOR DINING PURPOSES FOR AN EXISTING RESTAURANT AT 72990 EL PASEO,
SUITE 3
The City of Palm Desert (City), in its capacity as the Lead Agency for this project under the California
Environmental Quality Act (CEQA), finds that the proposed project is categorically exempt under Section
15301 Existing Facilities (Class 1) of the CEQA; therefore no further environmental review is necessary
and a Notice of Exemption can be adopted as part of this project .
PROJECT LOCATION/DESCRIPTION:
PROJECT LOCATION: 72990 El Paseo, Suite #3 (Assessor’s Parcel Number: 640-170-013)
PROJECT DESCRIPTION: The project is a Conditional Use Permit to allow for an existing restaurant to
construct an attached, outdoor dining patio area. The plans include architecture and landscaping for the
outdoor area including a trellis, storage structure, walls, pavers, and furniture.
PUBLIC HEARING: NOTICE IS HEREBY GIVEN that the Planning Commission of the City of Palm
Desert, California, will hold a Public Hearing at its meeting on August 20, 2024. The Planning
Commission meeting begins at 6:00 p.m. in the Council Chamber at 73510 Fred Waring Drive, Palm
Desert, California. Pursuant to Assembly Bill 2449, this meeting may be conducted as a hybrid meeting
allowing public access via teleconference or in person. Options for remote participation will be listed on
the Posted Agenda for the meeting at: https://www.palmdesert.gov/our-city/committees-and-
commissions/commission-information.
PUBLIC REVIEW: The plans and related documents are available for public review Monday through
Friday from 8:00 a.m. to 5:00 p.m. by contacting the project planner, Carlos Flores. Please submit written
comments to the Planning Division. If any group challenges the action in court, issues raised may be
limited to only those issues raised at the public hearing described in this notice or in written
correspondence at or prior to the Planning Commission hearing. All comments and any questions should
be directed to:
Carlos Flores, AICP, Principal Planner
City of Palm Desert
73-510 Fred Waring Drive
Palm Desert, CA 92260
(760) 776-6478
cflores@palmdesert.gov
PUBLISH ONCE: RICHARD D. CANNONE, AICP, SECRETARY
August 9, 2024 PALM DESERT PLANNING COMMISSION
31
32
8'X40'CONTAINER
8' HEIGHT
FIREPLACE
1'-5"(E) GRADE LINE
EXISTING
BUILDING
(E)ELEV.
248.42'
(E)ELEV.
247.27'
(E)ELEV.
247.93'2'-6"9'-11"10'-0"44'-11"
20'-0"
PROPOSED TRELLIS SYSTEM23'-5"8"
(N) CURB
18'-0" EXISTING
PARKING STALL
HEATER HEATER
247.0'
(E) F.F.
EXISTING AISLE
2'-10"
(N)
PLANTER
3'-5"N1 N2 N5
(N)DRAINING
246.60'
SITE DRAINING, REFER
TO GRADING PLAN
N3
N11 N9
4'-0"6"
6
A-1.31
TYP
(E)ELEV.
247.30'(N)T.O.C.
247.00'(N)T.O.C.
247.00'
(E)ELEV.
246.84'
(E)CONCRETE
247.36'
EXISTING BUILDING
(E) GRADE LINE
40'-0"
PROPOSED TRELLIS SYSTEM
(E) GRADE LINE(E) GRADE LINE
(E) GRADE LINE
PROPOSED TRASH
ENCLOSURE
FIREPLACE
8'-0"
(N)CONTAINER
3'-4"10'-0"(E)T.O.C.
247.54'3'-4"EXISTING AISLE4'-5" (N) PLANTER8"11'-4" CLEAR42'-0"2'-6" CLEAR
18'-0" EXISTING
PARKING STALL8"6'-0" (N) PLANTEREXISTING AISLE
N1N1
N5
N5
N6
4'-0"6"4'-0"6"
N2N3
N11
N2 N3
3
A-1.30
TYP
3
A-1.30
TYP
1/4" - 1'-0"
SITE SECTIONS
FEBRUARY.29.2024
Sheet:
Date:
Scale:
PATIO REMODEL
FOR
WILDEST RESTAURANT
72990 EL PASEO #3
PALM DESERT CA,.
92260
z a y d a @ z b r a u n d e s i g n s . c o m
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
D E S I G N S
A-1.40
SITE SECTION
1/4"-1'-0"1
SITE SECTION
1/4"-1'-0"2
NEW KEYNOTES
NEW CURB PER CITY STANDARD, REFER TO CIVIL DRAWINGS
NEW CONCRETE SIDEWALK TO BE AMIN. OF 4" THICK
CONCRETE. FINISH TO MATCH EXISTING.
NEW PLANTER, REFER TO LANDSCAPE PLAN
NEW TREE, REFER TO LANDSCAPE PLAN
NEW 40" HIGH RETAINING WALL TO BE 8"X8"X16" SINGLE CORE
(BOTH SIDES) PRECISION BLOCK, COLOR: GREY MW & BLACK
250 MW BY ORCO.
NEW ASPHALT SURFACE & CAR STALL STRIPING TO MATCH
EXISTING
NEW HERB GARDEN BOX
PROPOSED HERB GARDEN WALL, MOUNTED ON CONTAINER.
NEW 6FT WIDE X 6'8" DOUBLE DOOR
EXISTING LIGHT POLE TO BE PROTECTED DURING
CONSTRUCTION.
NEW 5FT WIDE X 3'8" FT HIGH HYDRAULIC DOOR
N1
N2
N3
N4
N5
N6
N7
N8
N9
N10
N11
33
(E) F.F.
0"3'-2"5'-3 1/4"8'-0 1/2"2'-0"2'-6"1'-10 1/2"5'-0" 2'-0" 6'-0"10'-6 1/2"
+/- 40'-0"3'-8"3'-0"6'-8"6'-8"VERTICAL
WOOD
SIDING
WOOD SHELFFLAT SLEET SLATS
WELDED TO STEEL
TUBES
CONTAINER
PAINT
9
A-1.42
7
A-1.42
8
A-1.42
1X2 STEEL TUBE FRAME
WELDED TO CONTAINER.
PRIME AND PAINT
A.2 G L A.3A.3
(E) F.F.
0"
+/- 8'-0"+/- 8'-0"VERTICAL
WOOD
SIDING
9
A-1.42
8
A-1.42
7
A-1.42
G
(E) F.F.
0"
2'-4 1/2" 4'-4" 1'-4 1/2"
+/- 8'-0"3'-2"+/- 8'-0"STEEL PLAQUE WITH
LOGO ON WHITE
VERTICAL
WOOD
SIDING
8
A-1.42
9
A-1.42
G
(E) F.F.
0"
EQ.EQ.
+/- 40'-0"
VERTICAL
WOOD
SIDING
CONTAINER
PAINT
9
A-1.42
8
A-1.42
7
A-1.42
A.3 G 1'-4"FURRING STRIP
1 1/2"CONTAINERFLOOR
WELDED BOLT TO
CONTAINER
3/4"SIDING BOARD
CONT. WOOD
FURRING STRIP
CONTAINER
FASTENER PER MFR
SPECS
SIDING BPOARD
CORNER TRIM
PRIMED AND PAINT
FURRING STRIP
CONTAINER
SIDING
BOARD
TOP TRIM
PRIMED AND PAINT
CONTINIOUS
SEALANT GLUE
FURRING STRIP
Sheet:
Scale:
Date:
ADU
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
As indicated
A-1.42
CONTAINER DETAILS
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
5CONTAINER ISOMETRIC
1/2" = 1'-0"3FRONT
1/2" = 1'-0"1SIDE -BACK
1/2" = 1'-0"2SIDE-FRONT
1/2" = 1'-0"4BACK
1" = 1'-0"6VERTICAL INSTALLATION
3" = 1'-0"7FLOOR GAP
3" = 1'-0"8CORNER TRIM
3" = 1'-0"9TOP TRIM
34
Sheet:
Scale:
Date:
ADU
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
A-2.00
MATERIAL BOARD
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
MATERIAL KEYNOTES
A. WALL PAINT (EXISTING)
MFR: SHERWIN WILLIAMS
COLOR: WORLDLY GRAY SW 7043
LRV: 57
A.1 WALL PAINT (EXISTING)
MFR: SHERWIN WILLIAMS
COLOR: POISED TAUPE SW 6039
LRV: 22
A.2 TRELLIS PAINT COLOR
MFR: SHERWIN WILLIAMS
COLOR: AESTHETIC WHITE SW 7035
LRV: 73
A.3 CONTAINER PAINT COLOR
MFR: SHERWIN WILLIAMS
COLOR: HULETT ORE SW 9574
LRV: 16
B. STONE VENEER
TO MATCH EXISTING
C. LIGHT FIXTURES
MFR: CONTARDI
STYLE: CALYPSO
MODEL: ANTIGUA, GUADALOUPE
AND MARTINIQUE
D. CMU BLOCK
MFR: ORCO BLOCK
COLOR: GRAY MW
STYLE: PRECISION BLOCK SINGLE CORE
COMMENTS: HORIZONTAL STRIPES
USING 2 COLORS, 1 COLOR PER ROW
E. CMU BLOCK
MFR: ORCO BLOCK
COLOR: BLACK 250 MW
STYLE: PRECISION BLOCK SINGLE CORE
COMMENTS: HORIZONTAL STRIPES
USING 2 COLORS, 1 COLOR PER ROW
M. COATED STEEL ROOF PANEL
MFR: ATAS INTERNATIONAL
COLOR: SANDSTONE 06
A
B
C
D
E
A.1 A.2
M
A.3
35
Sheet:
Scale:
Date:
ADU
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
A-2.01
MATERIAL BOARD
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
MATERIAL KEYNOTES
F. FIREPLACE
EXISTING TO REMAIN
G. WALL SIDING
MFR: NEW TECHWOOD
MODEL: US09
COLOR: PERUVIAN TEAK
PATTERN: WOOD GRAIN
PROFILE: FLUSH
H. PAVER
MFR: BELGARD
STYLE: MODULINE 6X12
COLOR: GRAPHITE
COMMENTS: SEE PLAN A-1.22 FOR
PAVER DESIGN
I. PAVER
MFR: BELGARD
STYLE: MODULINE 6X12
COLOR: FOUNDRY
COMMENTS: SEE PLAN A-1.22 FOR
PAVER DESIGN
J. PAVER
MFR: BELGARD
STYLE: MODULINE 6X12
COLOR: LINEN
COMMENTS: SEE PLAN A-1.22 FOR
PAVER DESIGN
K. METAL PLANTER
SEE LANDSCAPE PLAN FOR
LOCATION
SIZE: 24"X96"
L. OVERHEAD WINDOW
5' WIDE X 3'8" HEIGHT
HYDRAULIC DOOR
MATERIAL: CORRUGATED METAL TO
MATCH CONTAINER.
PAINT FINISH
MFR: SHERWIN WILLIAMS
COLOR: HULETT ORE SW 9574
F
G
H I J
K
L
36
Sheet:
Scale:
Date:
ADU
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
A-4.01
NEW
SOUTH WEST VIEW
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
37
Sheet:
Scale:
Date:
ADU
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
A-4.02
NEW SOUTH VIEW
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
38
Sheet:
Scale:
Date:
ADU
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
A-4.03
NEW WEST VIEW
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
39
Sheet:
Scale:
Date:
TRI-PLEX CONDOMINIUM
COMPLEX
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
A-4.05
CONTAINER VIEW
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
40
Sheet:
Scale:
Date:
TRI-PLEX CONDOMINIUM
COMPLEX
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
A-4.06
CONTAINER VIEW
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
41
Sheet:
Scale:
Date:
TRI-PLEX CONDOMINIUM
COMPLEX
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
A-4.07
CONTAINER VIEW
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
42
(E) F.F.
0"10'-0"20'-0" TRELLIS SYSTEM
CONTAINER
40'-0"
46'-7" NEW PATIO ADDITION
N11 N9
N5
(E) F.F.
0"
EXISTING BUILDING
3'-4"8'-0"10'-0"9'-4"CONTAINER
8'-0"
PROPOSED TRELLIS
40'-0"
N5
NEW CURB PER CITY STANDARD, REFER TO CIVIL
DRAWINGS
NEW CONCRETE SIDEWALK TO BE A MIN. OF 4"
THICK CONCRETE.
NEW PLANTER, REFER TO LANDSCAPE PLAN.
NEW TREE, REFER TO LANDSCAPE PLAN.
NEW 40" RETAINING WALL TO BE 8"X8"X16" SINGLE
CORE (BOTH SIDES) PRECISION BLOCK, COLOR:
GREY MW & BLACK 250 MW BY ORCO.
NEW ASPHALT SURFACE & CAR STALL STRIPING TO
MATCH EXISTING
NEW HERB GARDEN BOX
PROPOSED HERB GARDEN WALL, MOUNTED ON
CONTAINER.
NEW 6FT WIDE X 6'8"H DOUBLE DOOR
EXISTING LIGHT POLE TO BE PROTECTED DURING
CONSTRUCTION.
NEW 5FT WIDE X 3'8" FT HIGH HYDRAULIC DOOR
NEW KEYNOTES
N1
N2
N3
N4
N5
N6
N7
N8
N9
N10
N11
Sheet:
Scale:
Date:
ADU
FOR
7 6 0 . 8 9 8 . 4 8 6 5
w w w . Z b r a u n d e s i g n s . c o m
z a y d a @ z b r a u n d e s i g n s . co m
As indicated
A-4.10
EXTERIOR ELEVATIONS
JULY.01.2024
WILDEST RESTAURANT
72990 EL PASEO #3 PALM DESERT
CA. 92260
1/4" = 1'-0"1EAST ELEVATION
1/4" = 1'-0"2SOUTH ELEVATION
43
44
Statutory Exemptions. State code number:
_______________________________________________
Print Form
Notice of Exemption Appendix E
From: (Public Agency): ____________________________To: Office of Planning and Research
P.O. Box 3044, Room 113 _______________________________________________Sacramento, CA 95812-3044
County Clerk
(Address)
___________________________
___________________________
County of: __________________
Project Title: ____________________________________________________________________________
Project Applicant: ________________________________________________________________________
Project Location - Specific:
Project Location - City: ______________________ Project Location - County:
Description of Nature, Purpose and Beneficiaries of Project:
_____________________
Name of Public Agency Approving Project: _____________________________________________________
Name of Person or Agency Carrying Out Project: ________________________________________________
Exempt Status: (check one):
Ministerial (Sec. 21080(b)(1); 15268);
Declared Emergency (Sec. 21080(b)(3); 15269(a));
Emergency Project (Sec. 21080(b)(4); 15269(b)(c));
Reasons why project is exempt:
Lead Agency
Contact Person: ____________________________ Area Code/Telephone/Extension: _______________
If filed by applicant: 1.Attach certified document of exemption finding.
2.Has a Notice of Exemption been filed by the public agency approving the project? Yes No
Signature: ____________________________ Date:
Signed by Lead Agency Signed by Applicant
Authority cited: Sections 21083 and 21110, Public Resources Code. Date Received for filing at OPR:
Reference: Sections 21108, 21152, and 21152.1, Public Resources Code.
_______________
Categorical Exemption. State type and section number: ____________________________________
______________________________________________
______________ Title: _______________________
Revised 2011
City of Palm Desert
73-510 Fred Waring Drive
Palm Desert, CA 92260
Riverside
2724 Gateway Drive
Riverside, CA 92507
CUP23-0015 Wildest Restaurant Outdoor Dining
Charissa Farley-Hay
72990 El Paseo, Suite #3 (APN: 640-170-013)
Palm Desert Riverside
The proposal is a request by Charissa Farley-Hay (Applicant), for consideration of a Design Review to approve
architecture and landscaping for an outdoor patio remodel for “Wildest Restaurant” (Restaurant), located at 72990
El Paseo, Suite #3 (Assessor’s Parcel Number: 640170013), within the Palms to Pines West Shopping Center.
City of Palm Desert
City of Palm Desert
X Section 15301; Class 1 - Existing Facilities
The application has complied with the requirements of the “City of Palm Desert Procedure for Implementation of CEQA” Resolution No. 2019-41, in that the Planning
Commission finds that the Project is exempt from CEQA per Section 15301 of the State CEQA guidelines as the Project is an Article 19, Section 15301 Existing
Facilities (Class 1) project. Class 1 consists of the operation, repair, maintenance, permitting, leasing, licensing, or minor alteration of existing public or private
structures, facilities, mechanical equipment, or topographical features, involving negligible or no expansion of existing or former use. The expansion is in an area where
all public services and facilities are available to allow for maximum development permissible in the General Plan and in an area that is not environmentally sensitive.
Additionally, the Project is not subject to any of the exceptions for categorical exemptions identified in CEQA Guidelines Section 15300.2.
Carlos Flores, Principal Planner 7607766478
6/18/2024 Principal Planner
n
45
46
Page 1 of 6
CITY OF PALM DESERT
PLANNING COMMISSION
STAFF REPORT
MEETING DATE: June 18, 2024
PREPARED BY: Carlos Flores, AICP, Principal Planner
REQUEST: CONSIDER ADOPTING A NOTICE OF EXEMPTION AND APPROVING A
CONDITIONAL USE PERMIT FOR AN OUTDOOR PATIO FOR DINING
PURPOSES FOR AN EXISTING RESTAURANT AT 72990 EL PASEO,
SUITE 3
RECOMMENDATION:
Adopt Planning Commission Resolution No. 2875 entitled, “A RESOLUTION OF THE
PLANNING COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, ADOPTING A
NOTICE OF EXEMPTION PURSUANT TO THE STATE OF CALIFORNIA ENVIRONMENTAL
QUALITY ACT (CEQA) AND APPROVING A CONDITIONAL USE PERMIT (CUP) FOR AN
OUTDOOR PATIO FOR DINING PURPOSES FOR AN EXISTING RESTAURANT AT 72990
EL PASEO, SUITE 3”
BACKGROUND/ANALYSIS:
The proposal is a request by Charissa Farley-Hay (Applicant), for consideration of a Design
Review to approve architecture and landscaping for an outdoor patio remodel for “Wildest
Restaurant” (Restaurant), located at 72990 El Paseo, Suite #3 (Assessor’s Parcel Number:
640170013), within the Palms to Pines West Shopping Center.
The Restaurant occupies the south end of an in-line commercial building (Building) within the
Palms to Pines West Shopping Center (Center). The Building has two (2) other commercial
tenants and shares parking with four (4) surrounding multi-tenant commercial buildings within
the Center. The Restaurant currently utilizes existing parking spaces for a temporary outdoor
dining area and seeks approval to have a permanent outdoor patio dining area. The proposed
project will remove five (5) existing parking spaces and add five (5) new parking spaces, resulting
in no net less to parking. The total parking required for the Center is 184 spaces based off uses,
including 18 spaces required for this Project. The Center was approved for a total of 27,021
square feet (sf) of retail/bank building and 10,548 sf of restaurant building with and has a total
of 166 on-site parking spaces and 18 on-street parking spaces adjacent to the Center. Sheet A-
1.20 of Attachment 3 (Project Plans) provides a parking count with information on how parking
is proposed to be shared within the Center.
The Architectural Review Commission (ARC) of the City of Palm Desert considered the request
and took the following action at its meeting of May 28, 2024:
47
City of Palm Desert – Planning Commission
CUP23-0015 Wildest Restaurant Outdoor Patio
Page 2 of 6
Following discussion, MOTION BY CHAIR VUKSIC, SECOND BY COMMISSIONER
MCAULIFFE, CARRIED 6-0 (VICE CHAIR MCINTOSH ABSENT); the ARC approved Case No.
Design Review 23-0015 with the following conditions:
1. Roll up door shall be further studied and reviewed by staff regarding its
maintainability or be replaced with swinging metal doors.
2. A pilaster with the same stone cladding on the building shall be added to the
opening at the northeast corner of the patio.
3. Gravel placed in planters adjacent to the parking lot shall match existing parking
lot gravel.
4. Shipping container shall be new or like-new condition.
All of these conditions have been added as conditions of approval in the draft Resolution No.
2874.
Project Description:
A. Property Description:
The project site is a 1.12-acre parcel within the Center. The Restaurant is located on the south
end of the Building, as shown on Exhibit 1.
Exhibit 1 – Restaurant Site Plan
48
City of Palm Desert – Planning Commission
CUP23-0015 Wildest Restaurant Outdoor Patio
Page 3 of 6
B. Zoning, General Plan, and Adjacent Uses
Table 1 – Adjacent Land Use and Designations
Existing Uses General Plan Zoning
Project
Site Existing Commercial Regional Retail Planned Commercial – 3 (P.C.-3),
S.P.
North Existing Commercial Regional Retail Planned Commercial – 3 (P.C.-3),
S.P.
South Existing Residential Small Town
Neighborhood Planned Residential – 6 (PR-6)
East Existing Commercial Regional Retail Planned Commercial – 3 (P.C.-3),
S.P.
West Existing Commercial Regional Retail Planned Commercial – 3 (P.C.-3),
S.P.
C. Project Description
The Applicant is requesting Design Review approval for a 2,977 square foot (sf) outdoor
permanent dining patio which would include: a pergola/trellis, 8’ x 40’ storage container,
fireplace, heaters, lighting, pavers, wall, and landscaping on the perimeter and interior of the
patio. The total usable area for patio dining purposes would be 2,233 square feet.
Architecture
The proposal includes construction and installation of a 20’ x 40’ trellis, an 8’ x 40’ container,
perimeter walls, and furniture within the patio, including tables, chairs, and a fireplace.
Attachment 3 provides details on the proposed architecture of the expansion, which serves to
expand the existing Restaurant, and can be summarized below:
- Pergola: the Pergola is 10’ in height, 20’ in depth, and 40’ in length. It will be constructed
of aluminum painted white installed with six (6) posts and include ceiling fans and heaters,
downlights, and be used for dining. The posts will be cladded with stone veneer at a total
height of 2’-4” on the post, to match existing building and wood molding.
- Container: A container measuring 8’ in height, 8’ in depth, and 40’ in length will be located
on the western part of the outdoor patio. The container will be galvanized steel painted
white, have a vinyl print design wrapped around it, and include a mounted herb garden
wall. The container will include a window, roller doors, and be used for Restaurant
storage.
- Block wall: A 40” high retaining wall to be constructed of grey and black precision block.
The wall will use the combination of colors, offsetting colors by row.
- Pavers: The patio will include pavers in graphite, foundry, and linen colors.
49
City of Palm Desert – Planning Commission
CUP23-0015 Wildest Restaurant Outdoor Patio
Page 4 of 6
Exhibit 2 - Renderings
Landscaping
The proposal includes landscaping on the perimeter, interior, and adjacent parking stalls, as
shown in exhibit 3. The landscaping palette plan includes trees (pygmy date palms, palo verdes,
palo blancos, and laurel figs), shrubs and accents, “Pink Powderpuff” vines, and green carpet
natal plum ground cover.
Exhibit 3 – Landscaping Plan
50
City of Palm Desert – Planning Commission
CUP23-0015 Wildest Restaurant Outdoor Patio
Page 5 of 6
Public Notice:
Public Notification
Public noticing was conducted for this Planning Commission meeting per the requirements of
the Palm Desert Municipal Code (PDMC). A public hearing notice was published a minimum of
10 days before the hearing date on Friday, June 7, 2024, in The Desert Sun newspaper. Notices
were mailed to all property owners within 300 feet of the project site. No comments have been
received to date.
Environmental Assessment/Environmental Review:
The application has complied with the requirements of the “City of Palm Desert Procedure for
Implementation of CEQA” Resolution No. 2019-41, in that the Planning Commission finds that
the Project is exempt from CEQA per Section 15301 of the State CEQA guidelines as the Project
is an Article 19, Section 15301 Existing Facilities (Class 1) project. Class 1 consists of the
operation, repair, maintenance, permitting, leasing, licensing, or minor alteration of existing
public or private structures, facilities, mechanical equipment, or topographical features, involving
negligible or no expansion of existing or former use. The expansion is in an area where all public
services and facilities are available to allow for maximum development permissible in the
General Plan and in an area that is not environmentally sensitive.
Additionally, the Project is not subject to any of the exceptions for categorical exemptions
identified in CEQA Guidelines Section 15300.2:
1) The Project qualifies as a Class 1 exemption, which is not listed as one of the classes
under 15300.2 (A). The Project is not located on a site where it may have an adverse impact on
an environmental resource of hazardous or critical concern where designated, precisely
mapped, and officially adopted pursuant to law by federal, state, or local agencies. The Project
site will not impact designated environmental or biological resources as it is not located within a
conservation area as identified by the (MSHCP).
2) The Project will not have a cumulative impact on the environment. There are no other or
previous projects that have occurred in succession in the same place, of the same type, to
include a cumulative impact.
3) There are no unusual circumstances identified in relation to the proposed use or Project
site which would result in a significant impact on the environment. The Project site is not located
within a flood zone per the latest FEMA Flood Zone Maps. The Project site is located within a
Very High area per Fire Hazard Severity Zone maps depicted in Figure 8.5 on Page 119 of the
General Plan. The nearest fire station is located less than ½ mile east of the Project site. The
Project site is not identified within an Alquist-Priolo Fault Zone per the latest maps on file with
the California Department of Conservation; the nearest fault zone is the San Andreas Fault
located north of the Palm Desert City Limits.
4) The Project site is located within 300 feet of Highway 74, which is a State Scenic Highway.
The project, as condition, will not result in any damage to this scenic resource. The project is
proposing an outdoor dining patio with construction limited to an attached trellis, walls, storage,
51
City of Palm Desert – Planning Commission
CUP23-0015 Wildest Restaurant Outdoor Patio
Page 6 of 6
and landscaping. The project meets all development standards of the underlying zone and is not
proposing a structure height above existing buildings. This proposal is for use of an outdoor area
for dining purposes and does not propose any construction that would cause damage to Highway
74. The applicant utilizes landscaping throughout the project site to beautify the area.
5) Hazardous Waste Site: The Project site has not been identified as a hazardous waste site
per maps and databases provided by the California Department of Toxic Substances Control
(DTSC).
6) The Project site does not contain any structure or title that would designate it as a
historical resource. Therefore, the Project will not cause a substantial adverse change in the
significance of a historical resource.
Findings of Approval:
Findings of Approval can be found in draft Resolution No. 2875 (Attachment 1)
ATTACHMENTS:
1. Draft Resolution No. 2875
2. Architectural Review Commission Notice of Action
3. Project Plans
4. Public Hearing Notice
5. Draft Notice of Exemption
52
Page 1 of 6
CITY OF PALM DESERT
PLANNING COMMISSION
STAFF REPORT
MEETING DATE: August 20, 2024
PREPARED BY: Carlos Flores, AICP, Principal Planner
REQUEST: CONSIDERATION TO ADOPT A MITIGATED NEGATIVE DECLARATION
AND APPROVE A CONDITIONAL USE PERMIT AND PRECISE PLAN
FOR THE LIVING DESERT ZOO AND GARDENS EXPANSION PROJECT
RECOMMENDATION:
Adopt Resolution No. 2877, entitled “A RESOLUTION OF THE PLANNING COMMISSION
OF THE CITY OF PALM DESERT, CALIFORNIA, ADOPTING A MITIGATED NEGATIVE
DECLARATION (CEQA) PURSUANT TO THE CALIFORNIA ENVIRONMENTAL QUALITY
ACT AND APPROVING A CONDITIONAL USE PERMIT AND PRECIS E PLAN FOR THE
LIVING DESERT ZOO AND GARDENS EXPANSION PROJECT LOCATED AT 47900
PORTOLA AVENUE (ASSESSOR’S PARCEL NUMBER 630-250-045 & 625-300-052)”
BACKGROUND/ANALYSIS:
This item was originally on the July 16, 2024, agenda but was continued due to lack of quorum.
A three-phase master plan for the Living Desert was approved by the City of Pa lm Desert
Planning Commission in 2015 under Precise Plan (PP) / Conditional Use Permit (CUP) 15-370
via Planning Commission Resolution No. 2680. Phases 1 and 2 included construction of a new
entry plaza, ticket sales building, gift shop, legacy garden parking lot modifications, and six (6)
new animal exhibits. Phase 3 was planned for a new banquet hall building and associated
structures to be constructed at a future time, and is the current project proposed.
Additionally, the Living Desert received approval for PP22-0001 by the Planning Commission
(PC) on July 5, 2022, via PC Resolution 2815 which included expansion of the existing parking
lot, a new 10,356 square-foot (sf) administrative facilities building, and a 4,261 sf storage
building.
The proposal is a request by Prest Vuksic Greenwood Architects (Applicant) on behalf of the
Living Desert (Owner) to develop a new 37,650 sf event center, a second-story administrative
office, a new 1,250 sf entrance structure, and the addition of three (3) new lion h abitats within
the existing Living Desert Zoo and Gardens facility (Living Desert), as part of Phase 3.0 of the
Living Desert Master Plan. The proposed improvements have been reviewed and found to
comply with the applicable development standards.
53
City of Palm Desert – Planning Commission
CUP/PP/EA23-0010
Page 2 of 6
Architectural Review Commission (ARC)
On April 9, 2024, the City’s ARC took the following action after consideration of Design Review
Approval for the project:
Following discussion, MOTION BY COMMISSIONER LATKOVIC, SECOND BY
COMMISSIONER MCAULIFFE, CARRIED 6-0 (CHAIR VUKSIC RECUSED); to approve Case
No. DR23-0010 as presented.
Project Description:
A. Property Description
The project site (Site) is an existing zoo and nature preserve located off Portola Avenue, within
the City of Palm Desert and City of Indian Wells. Approximately 32.74 acres of the facility are
within the City of Palm Desert. The approximate gross acreage of the currently proposed project
is 5 acres.
B. Zoning, General Plan and Adjacent Uses
Table 1 Adjacent Land Use and Designations
Existing Uses Zoning
Project
Site
Living Desert Public Institution (P)
North Existing Residential PR-3
South Existing Residential PR-7
East City of Indian Wells N/A
West Existing Residential PR-3 and PR-7
C. Project Description
The applicant is proposing the following:
- A new “Connie and Bob Lurie Event Center” (Event Center) which will total 37,650 sf
inclusive of: 13,130 sf event space, 20,620 sf kitchen and back of house, and 7,490
sf administrative office.
- A new 1,250 sf entrance/ticketing structure (Entry Pavilion)
- Three (3) new lion habitats (Lion Habitat) totaling approximately 36,000 sf, complete
with lion care facilities, shade/viewing structures, and interactive pathways.
Site Plan
The site plan (Figure 1 on the following page) shows the location of the proposed buildings and
new lion habitats. The buildings will be incorporated into the existing Living Desert and
complement existing buildings and operations. The new Entry Pavilion will be located directly
west of the existing Chase Building. The Event Center will be north of the entry pavilion and
include views of the new Lion Habitats.
54
City of Palm Desert – Planning Commission
CUP/PP/EA23-0010
Page 3 of 6
There are no proposed changes to parking or off -site improvements as part of this project.
Previously approved and constructed improvements from PP15 -370 and PP22-0001 included
improvements to Portola Avenue and the addition of parking spaces which will as sist in
accommodating the currently proposed project.
Figure 1 – Site Plan
Architecture
The proposed project architecture for all of the new buildings is characterized as modern desert
contemporary utilizing natural stone veneer, corten steel panels, cemrock, and glass blocks.
The buildings architecture are consistent with each other and wit h the existing Living Desert
buildings and the environment within the project site. The buildings include mostly tan colors and
incorporate shade elements, glass to view the zoo operations, and rock features throughout the
buildings. The Lion Habitats include thatch roofs, rocks, glass, shades, and special design
considerations for the zoo operations.
55
City of Palm Desert – Planning Commission
CUP/PP/EA23-0010
Page 4 of 6
Figure 2 – Elevations (Event Center)
Figure 3 – Elevations (Entry Pavilion)
56
City of Palm Desert – Planning Commission
CUP/PP/EA23-0010
Page 5 of 6
Figure 4 – Elevations (Lion Habitat)
Landscaping
The applicant proposes a total of 29,573 sf of new landscaping surrounding all of the newly
proposed buildings and Lion Habitats. The landscape palette will include palm trees of different
sizes and species, shade trees, and rocks and grass throughout the are a which are consistent
and complementary with the existing landscaping and natural environment at the Living Desert.
ANALYSIS
Development Standards
The zoning designation is Public Institution (P). Development in the P zone is subject to
development standards provided under PDMC 25.22.040. The current project meets all the
development standards in the P zone. The applicant must still undergo final staff review for
compliance with Engineering and Fire Department requirements.
Environment Assessment/Environmental Review:
Under the California Environmental Quality Act (CEQA) and the State CEQA guidelines, an Initial
Study has been prepared to analyze the environmental impacts of the project. The documents
have been completed in compliance with the CEQA, the State CEQA Guidelines, and the City
of Palm Desert local CEQA guidelines. The document finds that all environmental impacts of the
project are either insignificant or can be mitigated to a less than significant level pursuant to the
mitigation measures outlined in the Mitigated Negative Declaration (MND). The Mitigated
Negative Declaration and the corresponding Mitigation Monitoring Reporting Program can be
found attached to Attachment 1 (Resolution) as “Exhibit A”.
57
City of Palm Desert – Planning Commission
CUP/PP/EA23-0010
Page 6 of 6
The City published a Notice of Intent to Adopt a Mitigated Negative Declaration on June 10,
2024, in accordance with CEQA guidelines. The public review period for the MND was from June
10, 2024, through July 1, 2024. The City received two (2) comment letters which have been
responded to (Attachment 6).
Public Notification:
Public noticing was conducted for the meeting of July 16, 2024, Planning Commission meeting
per the requirements of PDMC Section 25.60.060 and Government Code Sections 65090 to
65095. During the meeting, the project was continued to a date certain of August 6, 2024, due
to a lack of quorum. The August 6, 2024, Planning Commission meeting was subsequently
canceled due to a lack of quorum for the project.
Public noticing was conducted for the meeting of August 20, 2024, Planning Commission
meeting per the requirements of PDMC Section 25.60.060 and Government Code Sections
65090 to 65094. A public hearing notice was published a minimum of 10 days before the hearing
date on Friday, August 9, 2024, in The Desert Sun newspaper. Notices were mailed to all
property owners within 300 feet of the project site. One comment letter was received (Attachment
7).
The Applicant held a Community Engagement meeting on May 29, 2024, at the Living Desert
Zoo and Gardens. The meeting was attended by approximately 80+ people. Residents asked
questions on the process for lion habitats, timeline, and zoo mechanics. There was positive
feedback on the project from the residents, including p raise for the Living Desert on their traffic
circulation changes during events.
Findings of Approval:
Findings of Approval can be found in Attachment 1, Resolution 2877.
Legal Review
This report was reviewed by the City Attorney’s office.
ATTACHMENTS:
1. Draft Resolution No. 2877
Exhibit A ISMND
Exhibit B Conditions of Approval
2. Project Plans
3. ARC Minutes (April 9, 2024)
4. Public Hearing Notice
5. Community Meeting Flyer
6. ISMND Response to Comments
7. Public Comment
58
PLANNING COMMISSION RESOLUTION NO. 2877
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF PALM
DESERT, CALIFORNIA, ADOPTING A MITIGATED NEGATIVE
DECLARATION PURSUANT TO THE CALIFORNIA ENVIRONMENTAL
QUALITY ACT (CEQA) AND APPROVING A CONDITIONAL USE PERMIT
AND PRECISE PLAN FOR THE LIVING DESERT ZOO AND GARDENS
EXPANSION PROJECT LOCATED AT 47900 PORTOLA AVENUE
(ASSESSOR’S PARCEL NUMBER 630-250-045 & 625-300-052)
CASE NO. CUP/PP/EA23-0010
WHEREAS, Prest Vuksic Architects (“Applicant”) submitted applications for a
Conditional Use Permit (CUP), Precise Plan (PP), and Environmental Assessment to
construct a new event center, administration office, and lion habitat at the existing Living
Desert Zoo and Gardens Facility located at 47900 Portola Avenue (APNs 630-250-045 &
625-300-052); and
WHEREAS, the Planning Commission of the City of Palm Desert, California, did on
the 19th day of October 2016, adopt Resolution No. 2680, adopting a Mitigated Negative
Declaration (MND) of Environmental Impact pursuant to the California Environmental Quality
Act (CEQA), and approving a Conditional Use Permit and Precise Plan (PP/CUP 15-370) for
the Living Desert’s Master Plan of three (3) phases of the Living Desert ; and
WHEREAS, the Applicant submitted CUP/PP/EA23-0010 to amend PP/CUP15-370;
and
WHEREAS, the Project site has a land use designation of Public Facility/Institutional
in the General Plan adopted on November 10, 2016, and a Zoning Designation of Public
Facility; and
WHEREAS, the Architectural Review Commission (ARC) of the City of Palm Desert,
California, did on the 9th day of April 2024, approve a design review for the Project; and
WHEREAS, under Section 21067 of the Public Resources Code, Section 15367 of the
State California Environmental Quality Act (CEQA) Guidelines (Cal. Code Regs., tit. 14, §
15000 et seq.) and the City of Palm Desert’s (“City’s”) Local CEQA Guidelines, the City is the
lead agency for the Project; and
WHEREAS, pursuant to the requirements of the CEQA, the State Guidelines for the
Implementation of CEQA (State CEQA Guidelines) and the City of Palm Desert CEQA
Implementation Requirements Resolution No. 2024-035, a Mitigated Negative Declaration
(State Clearinghouse Number: 2024060302) and an accompanying Mitigation Monitoring and
Reporting Program (MMRP) were prepared for the Project, and are included as “Exhibit A” to
this Resolution; and
WHEREAS, the Planning Commission of the City of Palm Desert, California, did on
the 16th day of July 2024, hold a duly noticed public hearing to consider the request by the
Applicant for approval of the above-noted Project request and continued the project due to a
lack of quorum; and
59
PLANNING COMMISSION RESOLUTION NO. 2877
2
WHEREAS, the Planning Commission of the City of Palm Desert, California, did on
the 20th day of August 2024, hold a duly noticed public hearing to consider the request by the
Applicant for approval of the above-noted Project request; and
WHEREAS, at the said public hearing, upon hearing and considering all testimony and
arguments, if any, of all interested persons desiring to be heard, the Planning Commission
did find the following facts and reasons, which are outlined in the staff report, exist to justify
approval of said request:
NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of
Palm Desert, California, as follows:
SECTION 1. Recitals. The Planning Commission hereby finds that the foregoing
recitals are true and correct and are incorporated herein as substantive findings of this
Resolution.
SECTION 2. Findings on Conditional Use Permit. Under PDMC Section 25.72.050(F),
the findings for the CUP are the following:
1. The proposed location of the conditional use is in accord with the objectives of this
title and the purpose of the district in which the site is located.
The location of the conditional use is an expansion of the existing Living Desert
Zoo and Gardens. The project, as conditioned, is designed to meet the purpose of
the district in which the site is located and would allow for the continued use of an
existing and operational zoo and garden use.
2. The proposed location of the conditional use and the conditions under which it
would be operated or maintained will not be detrimental to the public health, safety,
or welfare, or be materially injurious to properties or improvements in the vicinity.
The Project is located as infill of the existing Living Desert and would continue to
operate with similar operations as the existing facility. The project, as conditioned,
has been analyzed to ensure that the expansion of a new habitat and event center
will not be detrimental to the public health, safety, or welfare, or be materially
injurious to properties or improvements in the vicinity. Event coordination has
occurred to ensure proper vehicular and pedestrian circulation. The project will
need to operate consistent with the operations outlined in the MND.
3. The proposed conditional use will comply with each of the applicable provisions of
this title, except for approved variances or adjustments.
The project, as conditioned, is designed to meet the purpose of the Public Facility
district in which the site is located. The project continues the existing operations of
the Living Desert Zoo and Gardens and does not propose any different uses than
established.
60
PLANNING COMMISSION RESOLUTION NO. 2877
3
4. The proposed conditional use complies with the goals, objectives, and policies of
the City’s General Plan
The subject property is designated Public Facility/Institutional District in the City’s
General Plan which allows facilities giving a wide range of public uses, higher
educational facilities, and other similar uses. The Living Desert Zoo and Gardens
has been operational and established for decades in this location as a zoo and
garden area with open space and educational intent. Specifically, the following
General Plan Goals and policies are being met:
Land Use Goal 1 Quality Spaces. The project will allow for the continuance of “A
beautiful city with a balance of high quality open spaces and high quality urban
areas”.
Land Use Goal 7 The Arts. The project allows for “A high quality of life and strong
community identity enhanced by rich arts and culture programs”.
Land Use Goal 8 Economic Development. The project achieves the goal of having
a diverse, growing, and resilient local economy with the expansion of this
attraction.
Land Use Policy 8.7 Natural Environmental. The project maintains and enhances
the natural environment as a critical attraction to tourists.
SECTION 3. Findings on Precise Plan. In recommending approval of this Project, the
Planning Commission, and under Palm Desert Municipal Code (PDMC) Section 25.72.030(E),
must make the following findings before granting a PP:
1. In the approval of this precise plan, consideration is given and restrictions are imposed
to the extent necessary, in view of the size and shape of the parcel and the present
and proposed zoning and use of the subject property and the surrounding property, to
permit the same degree of enjoyment of the subject property, but subject to the same
degree of protection of adjoining properties, as would be accorded in normal
circumstances by the standard restrictions imposed by Chapter 25.72.030. The
project, as conditioned, meets all of the requirements of the underlying zone and
provides this project the same allowances that its surrounding properties would be
governed by.
2. As conditioned, the proposed precise plan is not found to substantially depreciate
property values in the vicinity or unreasonably interfere with the use or enjoyment of
property in the vicinity by the occupants thereof for lawful purposes or would endanger
the public peace, health, safety, or general welfare.
3. A Design Review for the project architecture and landscape was reviewed and
approved as required by the Architectural Review Commission on April 9, 2024.
SECTION 4. CEQA Determination. The Planning Commission finds the Project has
been reviewed in compliance with the provisions of the CEQA. Under the CEQA and the State
61
PLANNING COMMISSION RESOLUTION NO. 2877
4
CEQA guidelines, an Initial Study has been prepared to analyze the environmental impacts
of the project. The documents have been completed in compliance with the CEQA, the State
CEQA Guidelines, and the City of Palm Desert local CEQA guidelines. The document finds
that all environmental impacts of the Project are either insignificant or can be mitigated to a
less than significant level pursuant to the mitigation measures outlined in the Mitigated
Negative Declaration. The Mitigated Negative Declaration and the corresponding Mitigation
Monitoring Reporting Program can be found attached to this Resolution as “Exhibit A”. The
Planning Commission determines that they adopt the MND.
SECTION 5. Project Recommendations. The Planning Commission hereby approves
CUP/PP/EA23-0010, subject to the findings and Conditions of Approval attached herein as
“Exhibit B”.
SECTION 6. Custodian of Records. The documents and materials that constitute the
record of proceedings on which these findings are based are located at the City’s office at
73510 Fred Waring Drive, Palm Desert, CA 92260. Richard D. Cannone, AICP, the Secretary
to the Palm Desert Planning Commission, is the custodian of the record of proceedings.
SECTION 7. Execution of Resolution. The Chairperson of the Planning Commission
signs this Resolution, and the Secretary to the Commission shall attest and certify to the
passage and adoption thereof.
SECTION 8. Recitals. The Planning Commission hereby finds that the foregoing
recitals are true and correct and are incorporated herein as substantive findings of this
Resolution.
ADOPTED ON August 20, 2024.
RON GREGORY
CHAIRPERSON
ATTEST:
RICHARD D. CANNONE, AICP
SECRETARY
62
PLANNING COMMISSION RESOLUTION NO. 2877
5
I, Richard D. Cannone, AICP, Secretary of the City of Palm Desert Planning
Commission, hereby certify that Resolution No. 2877 is a full, true, and correct copy, and was
duly adopted at a regular meeting of the Planning Commission of the City of Palm Desert on
August 20, 2024, by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
RECUSED:
IN WITNESS WHEREOF, I have hereunto set my hand and affixed the official seal of the City
of Palm Desert, California, on August ___, 2024.
RICHARD D. CANNONE, AICP
SECRETARY
63
64
Initial Study / Mitigated Negative Declaration
Living Desert Expansion Project
Case Nos.: CUP/PP/EA 23-0010
Lead Agency:
City of Palm Desert
73-510 Fred Waring Drive
Palm Desert, CA 92260
Contact:
Carlos Flores
Development Services Department
Prepared for:
City of Palm Desert
Prepared by:
Terra Nova Planning & Research, Inc.
42635 Melanie Place, Suite 101
Palm Desert, CA 92211
June 2024
65
66
i
Table of Contents
PROJECT DESCRIPTION ..................................................................................................................................... 1
ENVIRONMENTAL FACTORS POTENTIALLY AFFECTED ........................................................................ 15
DETERMINATION .............................................................................................................................................. 16
EVALUATION OF ENVIRONMENTAL IMPACTS ......................................................................................... 17
MONITORING PROGRAM FOR CEQA COMPLIANCE ................................................................................. 18
I. AESTHETICS........................................................................................................................... 20
II. AGRICULTURE RESOURCES ................................................................................................. 23
III. AIR QUALITY ......................................................................................................................... 25
IV. BIOLOGICAL RESOURCES .................................................................................................... 31
V. CULTURAL RESOURCES ....................................................................................................... 35
VI. ENERGY .................................................................................................................................. 38
VII. GEOLOGY AND SOILS ........................................................................................................... 40
VIII. GREENHOUSE GAS EMISSIONS ............................................................................................ 44
IX. HAZARDS AND HAZARDOUS MATERIALS ......................................................................... 47
X. HYDROLOGY AND WATER QUALITY ................................................................................. 50
XI. LAND USE AND PLANNING .................................................................................................. 55
XII. MINERAL RESOURCES .......................................................................................................... 57
XIII. NOISE ...................................................................................................................................... 58
XIV. POPULATION AND HOUSING ............................................................................................... 61
XV. PUBLIC SERVICES ................................................................................................................. 62
XVI. RECREATION ......................................................................................................................... 65
XVII. TRANSPORTATION ................................................................................................................ 66
XVIII. TRIBAL CULTURAL RESOURCES ......................................................................................... 71
XIX. UTILITIES AND SERVICE SYSTEMS ..................................................................................... 73
XX. WILDFIRE ............................................................................................................................... 78
XXI. MANDATORY FINDINGS OF SIGNIFICANCE ....................................................................... 81
List of Exhibits
Exhibit 1 Vicinity Map .......................................................................................................................... 5
Exhibit 2 Project Location Map ............................................................................................................. 6
Exhibit 3 Living Desert Area Use Map ................................................................................................. 7
Exhibit 4 Site Plan ................................................................................................................................. 8
Exhibit 5 Entry Pavilion Elevations ...................................................................................................... 9
Exhibit 6a Event Center Elevations ....................................................................................................... 10
Exhibit 6b Event Center Elevations ........................................................................................................11
Exhibit 7 Lion Habitat Care Center Elevations ................................................................................... 12
Exhibit 8 Lion Habitat Typical Viewing Structure .............................................................................. 13
Exhibit 9 Special Event Secondary Exit .............................................................................................. 14
67
ii
List of Tables
Table 1 Existing Facilities Living Desert ........................................................................................... 2
Table 2 Maximum Daily Construction-Related Emissions Summary (pounds per day) .................. 27
Table 3 Maximum Daily Operational-Related Emissions Summary (pounds per day) ................... 28
Table 4 Localized Significance Thresholds 25 Meters, 5 Acres (pounds per day) .......................... 29
Table 5 Palm Desert Register Landmarks ......................................................................................... 36
Table 6 Projected GHG Emissions Summary (metric tons/year) ..................................................... 45
Table 7 Indoor Water Demand at the Project Buildout .................................................................... 52
Table 8 Outdoor Water Demand at the Project Buildout .................................................................. 52
Table 9 Project Trip Generation Summary ....................................................................................... 68
Table 10 Project Parking Analysis ...................................................................................................... 69
Table 11 Estimated Solid Waste Disposal at Buildout ....................................................................... 77
List of Appendices
Appendix A CalEEMOD Air Quality and GHG Modeling .................................................................... A
Appendix B Geotechnical Investigation .................................................................................................. B
Appendix C Preliminary Hydrology Report ............................................................................................ C
Appendix D Trip and Parking Generation Analysis ............................................................................... D
68
-1-
CITY OF PALM DESERT
CEQA Environmental Checklist & Environmental Assessment
Project Title: Living Desert Expansion Project
Case No.: CUP/PP/EA 23-0010
Lead agency name and address: City of Palm Desert
73-510 Fred Waring Drive
Palm Desert, CA 92260
Contact persons and phone number: Carlos Flores
Development Services Department
City of Palm Desert
73-510 Fred Waring Drive
Palm Desert, CA 92260
(760) 346-0611 ext. 479
Project location: The Living Desert Zoo and Gardens, 47900 Portola Avenue, Palm Desert. Riverside
County.
Assessor’s Parcel Numbers (APNs) 630-250-045, 625-300-052
Project sponsor’s name and address: Prest Vuksic Greenwood Architects
44530 San Pablo Avenue, Suite 200
Palm Desert, CA 92260
General Plan Designation:
Public Facility/Institutional District
Zoning:
Public (P); Drainage, Flood Plains and Watercourse
Introduction
The Living Desert Zoo and Gardens, herein referred to as “Living Desert,” is proposing an expansion
project (Project) that includes the addition of an event center, entry pavilion, lion habitat, and associated
facilities. The Project is an amendment to the previous entitlement for the Living Desert (PP/CUP 15-
370), which included a smaller lion habitat and event center. In addition to the lion habitat and event
center, the Project introduces a new entry pavilion on the north side of the existing Chase building. The
Project consists of a Conditional Use Permit (CUP), Precise Plan (PP), and Environmental Assessment
(EA). The CUP is to allow construction of a “Recreation Facility, Commercial” use in the “Public”
zone.
The Living Desert was established in 1970 and is a ±72-acre wildlife park and conservation research
center that offers attractions such as wildlife exhibits, gardens, educational programs, and playgrounds.
The zoo includes ±32-acres of wildlife exhibits and learning centers, ±15.36-acres of gardens, and
±63,648-square feet of administration and maintenance facilities. The Living Desert provides ±9-acres
of parking, including 858 standard parking spaces, 20 ADA spaces, 14 bus spaces, and 45 employee
spaces (total of 937 parking spaces) (See Exhibits 1 through 3). Table 1 provides a summary of the
existing facilities within the Living Desert. It is important to note that all Project components occur
within the existing Zoo footprint, and will not expand the land area of the Living Desert.
69
-2-
Table 1
Existing Facilities
Living Desert
Exhibit/Use Land
Area
(AC)
Total
Structures
(SF)
Giraffe Conservation 3.1 1,203
Village Watutu 2.5 4,977
Life Underground 4.2 906
Cheetah Habitat 0.7 0
Eastern Africa Gardens 3.1 322
Aloe & Madagascar Gardens 2.2 0
Entry & Administration 2.2 23,389
Bighorn Sheep Exhibit 2.6 0
Train Exhibit 0.7 780
North American Reptiles 0.4 5,585
Australian Adventures 1.5 6,500
Learning and Impact Dept. 1.6 11,975
Tennity Amphitheater 1.1 4,822
Hoover Discovery Center 1.0 5,678
Gecko Park & Carousel 0.7 1,212
Desert Plant Conservation 0.6 795
Sonoran Aviary 0.6 2,326
Chihuahuan Garden 1.2 0
Eagle Canyon 1.8 5,300
Coatis Exhibit 0.6 236
Wildlife Hospital & Conservation Center 2.1 20,180
Coyote Exhibit 0.4 747
Sonoran Pond & Garden 1.3 543
Gardens 7.8 0
Facility Maintenance 22.4 40,259
Future Splash Pad (separate permit) 0.7 8,070
Future Bighorn Café (separate permit) 0.4 8,730
Current Project: Event Center & Lion Habitat 4.1 42,123
Total 72 204,474
The Living Desert is located within the boundaries of both the City of Palm Desert and the City of
Indian Wells. The City of Palm Desert is the lead agency and the original permitting jurisdiction. For
CEQA purposes, the City of Indian Wells is a “responsible agency.”
Project Description
The ±4.06-acre expansion Project is proposed for the center of the Living Desert immediately northeast
of the main entrance (see Exhibit 4). The Project site is currently developed with landscaping and
hardscapes that include pathways and an outdoor patio (Lurie Patio). There are no permanent building
structures within the proposed site, therefore the Project will not require the demolition of existing
structures.
70
-3-
Entry Pavilion: The entry pavilion is a 1,282-square foot entrance/ticketing structure to be located at
the north side of the Chase building and will serve as an entrance point for the new event center and for
daily school field trips into the Zoo. The entry pavilion is single-story with a maximum height of 23
feet when including architectural details. Improvements include a visitor kiosk, outdoor seating areas
and landscaping (see Exhibit 5).
Event Center: The event center includes 13,130-square feet of event space and outdoor patio areas that
can accommodate ±500 guests, as well as 20,620 square feet of kitchen and back of house space that
will serve the event center and provide support to existing retail food facilities within the Zoo, and a
second-story 7,490 square foot administration office with a direct connection to the existing Chase
building. The event center structure is two-stories with a maximum height of 31 feet when including
mechanical equipment, screening, and architectural details. The event center will be located
immediately east of the existing Chase building at the Park’s main entrance (see Exhibits 6a-6b).
The event center is projected to host two events per week from November to March, and one event per
week April through October. It is anticipated that large programs (<350 attendees), such as weddings,
will generally occur on weekends in the evening (including Friday evenings) whereas medium-sized
programs (100-350 attendees) would occur on weekends or weekdays in the evening, and small
programs (<100 attendees) could occur at any time throughout the day and week. Events such as
weddings would last 4-6 hours, banquets 2-4 hours, and smaller events 1-3 hours. Typical events would
start with loading/catering/rentals in the afternoon, with the event starting at 5:00 PM – 6:00 PM which
coincides with the Zoo’s decrease in general admissions in the afternoon. Deliveries would be
accommodated through the new service gate at the south Portola entrance or come directly to the event
center loading dock which is situated off the main public throughfare.
Lion Habitat: The lion habitat area occupies the eastern half of the Project area and includes three new
lion habitats consisting of 36,000 square feet, a 4,451-square-foot lion care facility, and associated
structures including open air pavilions, shade/viewing structures, and interactive pathways throughout
the exhibit. Structure heights will not exceed 22 feet. The lion care facility includes a keeper work area,
10 dens, and a day room (see Exhibits 7-8). The lion habitat will be accessible to park visitors during
normal business hours.
Proposed architecture is consistent with the Park’s existing aesthetic, incorporating natural desert colors
and materials such as rock boulders, round wood timber, thatched roofs, Corten steel panels, and natural
stone veneers (see Exhibits 5-8).
The primary vehicular access to the park is from Portola Avenue. A secondary exit point south of the
main entrance, also on Portola Avenue, will be utilized during special events and will be a right-turn
exit only (Exhibit 9). The Project does not propose changes to the Park’s existing ingress/egress. The
proposed expansion requires the removal of 1 ADA parking space for the new entry pavilion, resulting
in 19 ADA parking spaces for a new parking total of 936 spaces.
The Project requires the removal of existing hardscape and landscaping. There are approximately 245
mature trees in the project footprint that will be removed, 50 of which will be salvaged. Excess dirt
material will be stockpiled at the Living Desert’s maintenance yard at the northeast corner of the Zoo.
71
-4-
Surrounding Land Uses
The Project site is located within the Living Desert and is surrounded by zoo exhibits and
administrative/maintenance buildings. The Project site is currently developed with landscaping and
hardscapes that include pathways and an outdoor patio (Lurie Patio). There are no permanent building
structures within the proposed site.
North: Train exhibit, North American Reptiles exhibit, Kookaburra Café. Beyond the Living Desert is
open space/dry watercourse.
South: Main Living Desert entrance building, Life Underground exhibit. Beyond the Living Desert is
the Reserve Club (residential)
East: Bighorn exhibit, Aloe and Madagascar Gardens. Beyond the Living Desert is the Santa Rosa
Mountain foothills
West: Living Desert Chase building, parking. Beyond Living Desert is Portola Avenue and Corsican
Villas (residential)
Utilities and Service Providers
The following agencies and companies will provide services to the Project:
1. Sanitary Sewer: Coachella Valley Water District (CVWD)
2. Water: Coachella Valley Water District (CVWD)
3. Electricity: Southern California Edison (SCE)
4. Gas: Southern California Gas Company
5. Telephone/Cable: Frontier Communications/Spectrum
6. Storm Drains: City of Palm Desert, City of Indian Wells
7. Transit Service: SunLine Transit Agency
Other public agencies whose approval is or may be required (e.g., permits, financing approval, or
participation agreement.)
City of Indian Wells
Coachella Valley Water District
Regional Water Quality Control Board
72
73
74
75
76
77
78
79
80
81
82
-15-
ENVIRONMENTAL FACTORS POTENTIALLY AFFECTED:
The environmental factors checked below would be potentially affected by this project, involving at least
one impact that is a "Potentially Significant Impact" as indicated by the checklist on the following pages.
Aesthetics Agriculture and
Forestry Resources Air Quality
Biological Resources Cultural Resources Energy
Geology /Soils Greenhouse Gas
Emissions Hazards & Hazardous
Materials
Hydrology / Water
Quality Land Use / Planning Mineral Resources
Noise Population / Housing Public Services
Recreation Transportation Tribal Cultural Resources
Utilities/Service Systems Wildfire Mandatory Findings of
Significance
83
-16-
84
-17-
EVALUATION OF ENVIRONMENTAL IMPACTS:
1) A brief explanation is required for all answers except “No Impact” answers that are adequately
supported by the information sources a lead agency cites in the parentheses following each
question. A “No Impact” answer is adequately supported if the referenced information sources
show that the impact simply does not apply to projects like the one involved (e.g., the project falls
outside a fault rupture zone). A “No Impact” answer should be explained where it is based on
project-specific factors as well as general standards (e.g., the project will not expose sensitive
receptors to pollutants, based on a project-specific screening analysis).
2) All answers must take account of the whole action involved, including off-site as well as on-site,
cumulative as well as project-level, indirect as well as direct, and construction as well as
operational impacts.
3) Once the lead agency has determined that a particular physical impact may occur, then the checklist
answers must indicate whether the impact is potentially significant, less than significant with
mitigation, or less than significant. “Potentially Significant Impact” is appropriate if there is
substantial evidence that an effect may be significant. If there are one or more “Potentially
Significant Impact” entries when the determination is made, an EIR is required.
4) “Negative Declaration: Less Than Significant With Mitigation Incorporated” applies where the
incorporation of mitigation measures has reduced an effect from “Potentially Significant Impact”
to a “Less Than Significant Impact.” The lead agency must describe the mitigation measures, and
briefly explain how they reduce the effect to a less than significant level (mitigation measures from
“Earlier Analyses,” as described in (5) below, may be cross referenced).
5) Earlier analyses may be used where, pursuant to the tiering, program EIR, or other CEQA process,
an effect has been adequately analyzed in an earlier EIR or negative declaration. Section
15063(c)(3)(D). In this case, a brief discussion should identify the following:
a) Earlier Analysis Used. Identify and state where they are available for review.
b) Impacts Adequately Addressed. Identify which effects from the above checklist were
within the scope of and adequately analyzed in an earlier document pursuant to applicable
legal standards, and state whether such effects were addressed by mitigation measures
based on the earlier analysis.
c) Mitigation Measures. For effects that are "Less than Significant with Mitigation Measures
Incorporated," describe the mitigation measures, which were incorporated or refined from
the earlier document and the extent to which they address site specific conditions for the
project.
6) Lead agencies are encouraged to incorporate into the checklist references to information sources
for potential impacts (e.g., general plans, zoning ordinances). Reference to a previously prepared
or outside document should, where appropriate, include a reference to the page or pages where the
statement is substantiated.
7) Supporting Information Sources: A source list should be attached, and other sources used or
individuals contacted should be cited in the discussion.
8) This is only a suggested form, and lead agencies are free to use different formats; however, lead
agencies should normally address the questions from this checklist that are relevant to a project’s
environmental effects in whatever format is selected.
9) The explanation of each issue should identify:
a) The significance criteria or threshold, if any, used to evaluate each question; and
b) The mitigation measure identified, if any, to reduce the impacts to less than significance.
85
-18-
CITY OF PALM DESERT
MONITORING PROGRAM FOR CEQA COMPLIANCE
DATE: IN PROCESS ASSESSORS PARCEL NO.: 630-250-045, 625-300-052
PROJECT TITLE/
CASE NO.:
Living Desert Expansion Project
Case No.: CUP/PP/EA 23-0010
PROJECT LOCATION: The Living Desert Zoo and Gardens
47900 Portola Avenue, Palm Desert. Riverside County.
APPLICANT: Prest Vuksic Greenwood Architects
APPROVAL DATE: In progress
THE FOLLOWING REPRESENTS THE CITY’S MITIGATION MONITORING PROGRAM IN CONNECTION WITH THE MITIGATED
NEGATIVE DECLARATION FOR THE ABOVE CASE NUMBER
SUMMARY MITIGATION MEASURES
RESPONSIBLE
FOR
MONITORING
TIMING CRITERIA COMPLIANCE
CHECKED BY DATE
BIOLOGICAL RESOURCES
BIO.1 Migratory Bird Treaty Act
If ground disturbance or tree or plant removal
is proposed between January 15th and August
31st, a qualified biologist shall conduct a
nesting bird survey within 7 to 10 days of
initiation of grading onsite. If active nests are
reported, then species-specific measures shall
be prepared. At a minimum, grading in the
vicinity of a nest shall be postponed until the
young birds have fledged. For construction that
occurs between September 1st and January
31st, no pre-removal nesting bird survey is
required.
• In the event active nests are found,
exclusionary fencing shall be placed
around the nests until such time as
nestlings have fledged. Avoidance buffers
shall be 100 to 300 feet from the nests of
unlisted songbirds, and 500 feet from the
nests of birds-of-prey and listed species.
Project Biologist, City
Engineer, Planning
Department
Prior to issuance of
any permits that
result in ground
disturbance
The Project biologist shall
supply the City with reports
of findings regarding
burrowing owls and
migratory birds. The reports
will be attached to the
grading permit for the
Project.
TRIBAL CULTURAL RESOURCES
CUL-1 Prior to the issuance of any ground disturbing
permit on the site, the applicant shall
provide the City with a fully executed
Monitoring Agreement with ACBCI,
providing for a Tribal Monitor’s presence
during earth moving activities. The Tribal
Project applicant,
Tribal monitor,
Planning Division, City
Engineer.
Agreement to be
provided prior to
ground
disturbance.
Monitoring shall
Within 30 days of the
completion of monitoring
activities on the Project
site, a report of findings
shall be filed with the
86
-19-
SUMMARY MITIGATION MEASURES
RESPONSIBLE
FOR
MONITORING
TIMING CRITERIA COMPLIANCE
CHECKED BY DATE
Monitor shall have the authority to
temporarily stop construction if buried
resource(s) are found, but shall quickly
determine the significance of the find,
whether a qualified archaeologist must be
brought to the site to investigate the find,
and how it must be treated. Any resources
recovered shall be professionally
documented and deposited and curated in a
professional depository. The Tribal Monitor
shall be responsible for providing the City a
report of findings.
occur during earth-
moving activities.
City.
GEOLOGY
GEO.1 A site-specific Geotechnical Report shall be
submitted with grading plans, and report
recommendations should be incorporated in
Project design and construction.
Project engineer, Project
geotechnical consultant,
Project applicant.
Prior to issuance of
grading permits
Final report submitted to
and approved by the City
87
-20-
I. AESTHETICS
Except as provided in Public Resources
Code Section 21099, would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Incorporated
Less Than
Significant
Impact
No
Impact
a) Have a substantial adverse effect on a
scenic vista? ✓
b) Substantially damage scenic resources,
including, but not limited to, trees, rock
outcroppings, and historic buildings within a
state scenic highway?
✓
c) In non-urbanized areas, substantially
degrade the existing visual character or
quality of public views of the site and its
surroundings? (Public views are those that
are experienced from publicly accessible
vantage point). If the project is in an
urbanized area, would the project conflict
with applicable zoning and other regulations
governing scenic quality?
✓
d) Create a new source of substantial light or
glare, which would adversely affect day or
nighttime views in the area?
✓
Setting
The City of Palm Desert, including the project site, is located in Coachella Valley which is a desert valley
that extends approximately 45 miles in Riverside County, southeast from the San Gorgonio Pass to the
northern shore of the Salton Sea. The Coachella Valley is a low desert basin surrounded by dramatic
mountainous terrain created by the active geology that is characteristic of Southern California. The overall
gradient of the Valley is from northwest to southeast, gently sloping from the San Gorgonio Pass, at
approximately 2,600 feet above mean sea level, to the Salton Sea, which has a surface elevation of
approximately 228 feet below mean sea level.
The Valley and the Salton Sea are located within the Salton Trough, a fault-controlled valley formed by
the San Andreas Fault Zone. The Salton Trough is located within the Colorado Desert Geomorphic
Province, which is bounded to the southwest by the Peninsular Ranges province, to the north by the eastern
Transverse Ranges province, and to the northeast by the southeastern portion of the Mojave Desert
province. These tectonic forces have created the valley’s surrounding mountains, including the San Jacinto
Mountains, the foothills and slopes of which ascend from the Valley floor and form the westerly boundary
of the Coachella Valley. At its peak, Mount San Jacinto rises to an elevation of 10,834 feet above mean
sea level. The Santa Rosa Mountains, with Toro Peak at an elevation of 8,715 feet above mean sea level,
generally form the southerly boundary of the valley. In the northerly portion of the valley are the Indio
Hills, with elevations rising to about 1,600 feet, and the Little San Bernardino Mountains further north,
forming the northeasterly boundary of the valley.
88
-21-
The Project site is located within the Living Desert, on the City’s southeast boundary abutting the Santa
Rosa Mountain foothills. The site is centrally located in the Zoo and is currently developed with
landscaping and hardscapes.
Discussion of Impacts
a) Less Than Significant Impact. A significant impact may occur if the Project introduces
incompatible visual elements within a field of view containing a scenic vista, or substantially
blocks views of a scenic vista. Scenic vistas are generally described in two ways: panoramic views
(visual access to a large geographic area, for which the field of view can be wide and extend into
the distance) and focal views (visual access to a particular object, scene, or feature of interest).
The Project site is centrally located within the Living Desert and is surrounded by wildlife exhibits,
administrative and retail buildings, and desert landscaping. The Project site is developed with
mature landscaping and hardscapes including pathways and an outdoor patio area. There are no
permanent building structures within the Project area. Neither the Project site nor the Living Desert
is located in a scenic preservation overlay district.
From the subject site, scenic views of the Santa Rosa foothills are to the east, middle/upper views
of the Santa Rosa Mountains are to the south and west, and middle/upper views of the San
Bernardino Mountains and Indio Foothills are to the north. The Project site is located
approximately 100 feet west, 1.4 miles east, and 1.1 miles north of the Santa Rosa foothills, and
9.9 miles and 14.7 miles south of the Indio Foothills and San Bernardino Mountains, respectively.
From the Project site, much of the views of the lower elevations of the foothills in all directions
are blocked by intervening landscaping and structures within the Living Desert.
Construction of the Project would require the use of heavy equipment for grading, paving and
excavation. Construction activities would be visible from within the Zoo; however, impacts from
construction are temporary and would be fenced off from public view.
The Project proposes one- and two-story buildings and structures with a maximum height of 31
feet (event center), which is below the maximum height allowed in the Public/Institutional zone
of 35 feet. The proposed structures would be similar in height and style to neighboring exhibit
structures, retail buildings, and the Chase building, which is also a two-story building.
Visitors of the Living Desert enjoy views of authentic desert landscaping, wildlife exhibits, and
the Santa Rosa Mountain foothills to the east, south and west. Views of the San Bernardino
Mountains and Indio foothills to the north are largely obstructed due to intervening development
and are further diminished by distance. The Project site is centrally located within the Living
Desert and is not directly adjacent to neighboring properties. The Project’s mass and scale is
consistent with existing uses within the Living Desert, and therefore will not impact views of the
scenic vistas from neighboring properties. Impacts are considered less than significant.
b) No Impact. A significant impact would occur only if scenic resources would be damaged and/or
removed by development of a project along a state scenic highway. Although the Project will
require the removal of existing landscaping, including mature trees, they are not located along a
state scenic highway. The only designated scenic highway in the city is Highway 74, which is ±1.3
miles west of the Project area. No impact will occur as a result of the Project.
89
-22-
c) Less Than Significant Impact. The Project site is in an urban setting; therefore, a significant
impact would occur if the Project conflicts with applicable zoning and other regulations governing
scenic quality. The Project will be consistent with applicable General Plan policies governing
scenic quality, which require preservation of view corridors of the hills and mountains and limited
light pollution to maintain darkness for night sky viewing (General Plan Environmental Resources
Element Policies 2.1 and 2.5). The Project is consistent with the City’s development standards for
the Public/Institutional zone. The Project has been designed in accordance with the development
standards and design guidelines found elsewhere in the Living Desert, including the use of natural
elements such as rock boulders, round wood timber, thatched roofs, corten steel panels, and natural
stone veneers. Therefore, the Project will have less than significant impacts to applicable
regulations that address scenic quality.
d) Less Than Significant Impact. A significant impact may occur if the proposed project introduces
new sources of light or glare on or from the project site which would be incompatible with the
areas surrounding the project site, or which pose a safety hazard to motorists utilizing adjacent
streets or freeways.
The Project will generate light and glare primarily from buildings, landscape lighting, and mobile
light sources from vehicles accessing the site during special events at the event center. All Project
lighting will comply with the City’s lighting standards, and the design of the Living Desert, which
requires lighting fixtures to complement the architecture and landscape, be designed and located
to avoid spillover onto adjacent lots and be low intensity to preserve the nighttime dark sky and
protect sensitive wildlife. The Project will be required to comply with Chapter 24.16 (Outdoor
Lighting Requirements) of the Municipal Code, including lighting performance criteria and design
guidelines. Landscape and lighting plans will be subject to review by the City. With adherence to
City standards and Living Desert requirements, Project-related impacts associated with increased
light and glare will be less than significant.
Mitigation Measures: None required.
Monitoring: None required.
Sources: Palm Desert Municipal Code; California State Scenic Highway System Map, Caltrans, 2018; Project materials.
90
-23-
II. AGRICULTURE RESOURCES
In determining whether impacts to agricultural resources are significant environmental effects, lead agencies may refer to the California
Agricultural Land Evaluation and Site Assessment Model (1997) prepared by the California Dept. of Conservation as an optional model
to use in assessing impacts on agriculture and farmland. In determining whether impacts to forest resources, including timberland, are
significant environmental effects, lead agencies may refer to information compiled by the California Department of Forestry and Fire
Protection regarding the state’s inventory of forest land, including the Forest and Range Assessment Project and the Forest Legacy
Assessment project; and forest carbon measurement methodology provided in Forest Protocols adopted by the California Air Resources
Board.
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Convert Prime Farmland, Unique
Farmland, or Farmland of Statewide
Importance (Farmland), as shown on the
maps prepared pursuant to the Farmland
Mapping and Monitoring Program of the
California Resources Agency, to non-
agricultural use?
✓
b) Conflict with existing zoning for
agricultural use, or a Williamson Act
contract?
✓
c) Conflict with existing zoning for, or cause
rezoning of, forest land (as defined in Public
Resources Code section 12220(g)),
timberland (as defined by Public Resources
Code section 4526), or timberland zoned
Timberland Production (as defined by
Government Code section 51104(g))?
✓
d) Result in the loss of forest land or
conversion of forest land to non-forest use? ✓
e) Involve other changes in the existing
environment which, due to their location or
nature, could result in conversion of
Farmland, to non-agricultural use or
conversion of forest land to non-forest use?
✓
Setting
Agriculture is a significant part of the Coachella Valley economy; however, agricultural land and
operations are located east of Palm Desert. The City is in a desert environment and has no forests or forest
production lands. It is predominantly built out with urban uses and does not contain any land designated
or zoned for agricultural uses. Neither the General Plan nor the Zoning Ordinance include forestry or
forest production designations. While not directly related to agriculture and forest uses, the General Plan
includes the potential for golf course reuse that may allow community-scale agricultural uses.
91
-24-
Discussion of Impacts
a-e) No Impact.
Farmland: The California Department of Conservation, Important Farmland Map provides the
most recent California Important Farmland data set mapping in which it identifies prime farmland,
farmland of statewide importance, and unique farmland. According to the Map, the City of Palm
Desert is not found on or adjacent to an area identified as significant farmland. No farmland of
statewide importance is found in Palm Desert or within the Living Desert’s grounds. For this
reason, the proposed Project will not alter or change agricultural lands to non-agricultural uses. No
impact is expected.
Williamson Act: In the City’s General Plan Land Use Designation Map (Figure 3.1), the Living
Desert is zoned Public (P). There are no Williamson Act contracts on Living Desert property, or
on adjacent properties. The proposed development is an expansion of uses within the Living
Desert’s existing boundaries and therefore no conflict regarding zoning designations or
Williamson Act is anticipated. No impact will occur.
Forest Lands: Palm Desert is characterized by a Southern California desert landscape which does
not support forestry or resources including timberland. There are no land use designations in the
City related to forestry. No forestry resources will be impacted as a result of the Project.
Overall, the addition of an event center, lion habitat, and associated structures within the existing
boundaries of the Living Desert will not convert farmland, agriculture, or forestry lands because
the site is currently a developed portion of the Zoo. For this reason, no impacts to farmland and
forestry are anticipated.
Mitigation Measures: None required.
Monitoring: None required
Sources: Palm Desert Municipal Code; California Important Farmland Finder, California Department of Conservation,
https://maps.conservation.ca.gov/ agriculture/DataViewer/index.html, accessed March 2024.
92
-25-
III. AIR QUALITY
Where available, the significance criteria
established by the applicable air quality
management district or air pollution
control district may be relied upon to
make the following determinations.
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Conflict with or obstruct implementation
of the applicable air quality plan? ✓
b) Result in a cumulatively considerable net
increase of any criteria pollutant for which
the project region is non-attainment under an
applicable federal or state ambient air
quality standard
✓
c) Expose sensitive receptors to substantial
pollutant concentrations? ✓
d) Result in other emissions (such as those
leading to odors adversely affecting a
substantial number of people?
✓
Setting
The Coachella Valley is in the Salton Sea Air Basin (SSAB), which includes part of Riverside County and
all of Imperial County. The SSAB is under the jurisdiction of the South Coast Air Quality Management
District (SCAQMD). All development within the SSAB is subject to the 2022 SCAQMD Air Quality
Management Plan (AQMP), and the Coachella Valley region is subject to the 2003 Coachella Valley PM10
State Implementation Plan (CV PM10 SIP). SCAQMD operates and maintains regional air quality
monitoring stations at numerous locations throughout its jurisdiction. The Project site is within Source
Receptor Area (SRA) 30, which includes monitoring stations in Palm Springs, Indio, and Mecca.
Criteria air pollutants are contaminants for which state and federal air quality standards have been
established. The SSAB exceeds state and federal standards for fugitive dust (PM10) and ozone (O3), and
is in attainment for PM2.5, except the City of Calexico. Ambient air quality in the SSAB, including the
Project site, does not exceed state and federal standards for carbon monoxide, nitrogen dioxides, sulfur
dioxide, lead, sulfates, hydrogen sulfide, or vinyl chloride.
Buildout of the proposed Project will result in air quality impacts during construction and operation. The
California Emissions Estimator Model (CalEEMod) Version 2022.1 was used to project air quality
emissions that will be generated by the Project (Appendix A).
Discussion of Impacts
a) No Impact. According to CEQA, a significant air quality impact could occur if the proposed
project is not consistent with the applicable Air Quality Management Plan (AQMP) or would
obstruct the implementation of the policies or hinder reaching the goals of that plan. The Project
site is within the Salton Sea Air Basin (SSAB) and will be subject to SCAQMD’s 2022 AQMP
93
-26-
and the 2003 Coachella Valley PM10 SIP. The AQMP is a comprehensive plan that establishes
control strategies and guidance on regional emission reductions for air pollutants. The AQMP is
based, in part, on the land use plans of jurisdictions in the region.
The Southern California Association of Governments (SCAG) adopted the 2020-2045 Regional
Transportation Plan/Sustainable Communities Strategy (2020 RTP/SCS) to comply with
metropolitan planning organization (MPO) requirements under the Sustainable Communities and
Climate Protection Act. The RTP/SCS Growth Management chapter forms the basis of land use
and transportation controls of the AQMP. Projects that are consistent with SCAG’s population
forecasts are considered consistent with the AQMP. SCAG forecasts that the City’s population
will be 64,100 in 2045.
A project is considered to be in conformity with adopted air quality plans if it adheres to the
requirements of the SCAQMD Rule Book, AQMP, and adopted and forthcoming control
measures, and is consistent with growth forecasts in the applicable plan(s) (or is directly included
in the applicable plan). Conformity with growth forecasts can be established by demonstrating that
a project is consistent with the land use plan that was used to generate the growth forecast. A non-
conforming project would be one that increases the gross number of dwelling units, increases the
number of vehicle trips, and/or increases the overall vehicle miles traveled in an affected area
relative to the applicable land use plan.
The General Plan was used to develop population forecasts in the above-described RTP/SCS, and
the RTP/SCS served as the basis for the AQMP. The Project is part of a planned expansion within
the Living Desert to include a new event center, lion habitat exhibit, and north entry pavilion. The
Project does not propose residential land uses and would not impact population, as employees of
the proposed Project are expected to be residents of the city and region, and current Living Desert
employees. The proposed Project would be implemented in accordance with all applicable rules
and regulations contained in air quality management plans to meet the applicable air quality
standards. Therefore, the Project is consistent with the AQMP and will not conflict with or obstruct
implementation of the plan. No conflict will occur.
b) Less Than Significant Impact. A project is considered to have significant impacts if there is a
cumulatively considerable net increase of any criteria pollutant for which the project region is in
non-attainment under an applicable federal or state ambient air quality standard. As previously
stated, the SSAB is currently a non-attainment area for PM10 and ozone. Therefore, if the Project’s
construction and/or operational emissions exceed SCAQMD thresholds for PM10 and ozone
precursors, which include carbon monoxide (CO), nitrous oxides (NOx), and volatile/reactive
organic compounds/gases (VOC or ROG), then impacts would be cumulatively considerable and
significant.
The California Emissions Estimator Model (CalEEMod) Version 2022.1 was used to project air
quality emissions that will be generated by the proposed Project (Appendix A). Criteria air
pollutants will be released during both the construction and operational phases of the Project, as
shown in Tables 1 and 2. Table 1 summarizes short-term construction-related emissions, and Table
2 summarizes ongoing emissions generated during operation.
94
-27-
Construction Emissions
Project buildout is anticipated to take 15-months. The construction period includes all aspects of
Project development, including site preparation, grading, paving, building construction, and
application of architectural coatings. Operational emissions represent the highest vehicle trip
generating scenario that include daily operations of the new administration and lion habitat uses,
and a large event (500 people) occurring every weekend after Zoo regular hours. The following
assumptions were input into CalEEMod:
• Combined administration space (7,490 SF), entry pavilion (1,282 SF) and lion care facility
(4,451 SF) totaling 13,223 SF of “general office building” space with a daily trip rate of
122 trips per the trip generation report (Appendix D). The 122 daily trips are applied to
weekdays and weekends.
• Combined event space (13,130 SF) and kitchen/B.O.H. space (20,620 SF) totaling 33,750
SF of “quality restaurant” with a daily trip rate of 350 trips per the trip generation report.
The 350 daily trips are only applied to weekends.
• 119,670 square feet of landscaping.
• No import of export of materials. Preliminary grading estimates a net import of 4,198 cubic
yards, however the material will be sourced from the Living Desert’s current stockpile
located within 1,000 of the Project area, from inside the park.
As shown in Table 2, emissions generated by construction activities will not exceed SCAQMD
thresholds for any criteria pollutant. Applicable standard requirements and best management
practices include, but are not limited to, the implementation of a dust control and management plan
in conformance with SCAQMD Rules 403 and 403.1, phased application of architectural coatings,
the use of low-polluting architectural paint and coatings per SCAQMD Rule 1113, and the use of
low water demand landscaping, as required by City and CVWD requirements.
Table 2
Maximum Daily Construction-Related Emissions Summary
(pounds per day)
Construction Emissions1 CO NOx ROG SO2 PM10 PM2.5
Daily Maximum 34.2 36.0 7.96 0.05 9.49 5.47
SCAQMD Thresholds 550.00 100.00 75.00 150.00 150.00 55.00
Exceeds? No No No No No No
Source: CalEEMod Version 2022.1 (output tables provided in Appendix A).
Given that criteria pollutant thresholds will not be exceeded, and standard best management
practices will be applied during construction, impacts will be less than significant.
Operational Emissions
Operational emissions are ongoing emissions that will occur over the life of the Project. They
include area source emissions, emissions from energy demand (electricity), and mobile source
(vehicle) emissions.
According to the Project traffic trip generation memo (Appendix D), the new administrative space
and lion exhibit will generate approximately 122 daily trips, and the event center will generate up
to 375 trips during a 500-guest special event (see Section XVII, Transportation). For CalEEMod
reporting, it is assumed the 122 trips will occur weekdays and weekends, and the 375 trips would
95
-28-
occur only on weekends. Table 3 summarizes projected emissions during operation of the Project
at build out. As shown, operational emissions will not exceed SCAQMD thresholds of significance
for any criteria pollutants for operations. Impacts will be less than significant.
Table 3
Maximum Daily Operational-Related Emissions Summary
(pounds per day)
Operational Emissions1 CO NOx ROG SO2 PM10 PM2.5
Daily Maximum 48.9 5.31 4.01 0.13 12.0 3.17
SCAQMD Thresholds 550 55 55 150 150 55
Exceeds? No No No No No No
Source: CalEEMod Version 2022.1 (output tables provided in Appendix A).
Cumulative Contribution
A significant impact could occur if the Project would make a considerable cumulative contribution
to federal or state non-attainment pollutants. The Coachella Valley portion of the SSAB is
classified as a “non-attainment” area for PM10 and ozone. Cumulative air quality analysis is
evaluated on a regional scale (rather than a neighborhood or city scale, for example), given the
dispersing nature of pollutant emissions and aggregate impacts from surrounding jurisdictions and
air management districts. Any development project or activity resulting in emissions of PM10,
ozone, or ozone precursors will contribute, to some degree, to regional non-attainment
designations of ozone and PM10.
The SCAQMD does not currently recommend quantified analyses of construction and/or
operational emissions from multiple development projects, nor does it provide methodologies or
thresholds of significance to be used to assess the significance of cumulative emissions generated
by multiple cumulative projects. However, it is recommended that a project’s potential
contribution to cumulative impacts be assessed utilizing the same significance criteria as those for
project-specific impacts. Furthermore, SCAQMD states that if an individual development project
generates less than significant construction or operational emissions, then the project would not
generate a cumulatively considerable increase in emissions for those pollutants for which the Basin
is in nonattainment.
As shown in the tables above, Project-related PM10, CO, NOx, and ROG emissions are projected
to be below established SCAQMD thresholds. Therefore, the proposed Project will result in
incremental, but not cumulatively considerable impacts on regional PM10 or ozone levels.
Summary
As shown above, both construction and operation of the Project will result in criteria emissions
below the SCAQMD significance thresholds, and neither would violate any air quality standard or
contribute substantially to an existing or projected air quality violation. Impacts related to
construction and operation will be less than significant and are not cumulatively considerable from
a non-attainment standpoint.
c) Less Than Significant Impact. Sensitive receptors include residences, schools, playgrounds,
childcare centers, retirement homes, hospitals, and other land uses occupied by individuals who
are potentially more sensitive to pollutants than the average. The Project site is centrally located
within the Living Desert which is occupied by visitors daily who walk in proximity to the site.
96
-29-
To determine if a project has the potential to generate significant adverse localized air quality
impacts, SCAQMD offers Localized Significance Thresholds (LST) analysis. Analysis of LSTs
by a local government is voluntary and is designed for projects that are less than or equal to 5
acres. The maximum area of disturbance associated with buildout of the Project is approximately
4 acres, and it is assumed that buildout will occur over one to two years. the 5-acre Mass Rate
Look-Up table is therefore appropriate under the SCAMD’s methodology to screen for potential
localized air quality impacts.1
The Mass Rate Look-Up tables for LSTs were used to determine if the proposed Project would
have the potential to generate significant adverse localized air quality impacts during construction.
The LST for Source Receptor Area (SRA) 30 (Coachella Valley) was used to determine LST
emission thresholds. The distance from the emission source and the maximum daily site
disturbance also determine the emission thresholds. For analysis purposes, the scenario of a
sensitive receptor being within 25 meters of the Project site was used. Only area source emissions
are considered when assessing operational impacts to sensitive receptors because all mobile
emissions would occur off-site, and parking will be provided in the existing Living Desert parking
lot.
Table 4 shows that LST thresholds are not expected to be exceeded for any criteria pollutant during
construction or operation. Impacts to sensitive receptors will be less than significant.
Table 4
Localized Significance Thresholds
25 Meters, 5 Acres
(pounds per day)
CO NOx PM10 PM2.5
Construction Emissions 34.2 36.0 9.49 5.47
LST Threshold 2,292 304 14 8
Operational Emissions 2.86 1.09 0.08 0.08
LST Threshold 2,292 304 4 2
Exceeds Threshold? No No No No
Source of Emission Data: CalEEMod version 2022.1 (output tables provided in Appendix A).
Source of LST Threshold: LST Mass Rate Look-up Table, 25 meters, 5 acres, SCAQMD
Health Impacts
As shown in Tables 2 and 3, construction and operation of the proposed Project will result in
criteria emissions that are below the SCAQMD significance thresholds, and neither would violate
any air quality standard or contribute substantially to an existing or projected air quality violation.
It is not scientifically possible to calculate the degree to which exposure to various levels of criteria
pollutant emissions will impact an individual’s health. There are several factors that make
predicting a Project-specific numerical impact difficult:
• Not all individuals will be affected equally due to medical history. Some may have medical
pre-dispositions, and diet and exercise levels tend to vary across a population.
1 SCAQMD “Fact Sheet for Applying CalEEMod to Localized Significance Thresholds.”
97
-30-
• Due to the dispersing nature of pollutants, it is difficult to locate and identify which group of
individuals will be impacted, either directly or indirectly.
• There are currently no approved methodologies or studies to base assumptions on, such as
baseline health levels or emission level-to-health risk ratios.
Due to these limitations, the extent to which the Project poses a health risk is uncertain but
unavoidable. It is anticipated that the impacts associated with all criteria pollutants will be less
than significant overall, and that health effects will also be less than significant.
d) Less Than Significant Impact. A significant impact could occur if objectionable odors are
generated that would adversely impact sensitive receptors. Odors are typically associated with
industrial projects involving the use of chemicals, solvents, petroleum products, and other strong-
smelling elements used in manufacturing processes, as well as in sewage treatment facilities and
landfills. The Project proposes an event center, entry pavilion, and lion habitat exhibit.
During construction, odors associated with construction activities will be generated. However, any
such odors would be short-term and quickly dispersed below detectable levels as distance from the
construction site increases. The Project does not propose land uses that cause odor impacts, such
as gas stations or industrial uses. During operations, the event center kitchen will generate odors
from cooking and there will be odors associated with wildlife. However, these uses and odors are
comparable to existing conditions in the Living Desert. In addition, the SCAQMD Rule 402
(Nuisance), and SCAQMD Best Available Control Technology Guidelines would limit potential
objectionable odor impacts during the proposed Project’s long-term operations phase. Therefore,
impacts from objectionable odors will be less than significant.
Mitigation Measures: None required.
Monitoring: None required.
Sources: SCAQMD AQMP, 2022; 2020-2045 Regional Transportation Plan/Sustainable Communities Strategy (RTP/SCS),
Demographics and Growth Forecast Technical Report, Southern California Association of Governments, adopted September
3, 2020; “Final Localized Significance Threshold Methodology,” prepared by the South Coast Air Quality Management
District, Revised, July 2008; “2003 Coachella Valley PM10 State Implementation Plan,” August 1, 2003; CalEEMod Version
2022.1; Project materials.
98
-31-
IV. BIOLOGICAL RESOURCES
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Have a substantial adverse effect, either
directly or through habitat modifications, on
any species identified as a candidate,
sensitive, or special status species in local or
regional plans, policies, or regulations, or by
the California Department of Fish and Game
or U.S. Fish and Wildlife Service?
✓
b) Have a substantial adverse effect on any
riparian habitat or other sensitive natural
community identified in local or regional
plans, policies, regulations or by the
California Department of Fish and Game or
US Fish and Wildlife Service?
✓
c) Have a substantial adverse effect on
federally protected wetlands (including, but
not limited to, marsh, vernal pool, coastal,
etc.) through direct removal, filling,
hydrological interruption, or other means?
✓
d) Interfere substantially with the movement
of any native resident or migratory fish or
wildlife species or with established native
resident or migratory wildlife corridors, or
impede the use of native wildlife nursery
sites?
✓
e) Conflict with any local policies or
ordinances protecting biological resources,
such as a tree preservation policy or
ordinance?
✓
f) Conflict with the provisions of an adopted
Habitat Conservation Plan, Natural
Community Conservation Plan, or other
approved local, regional, or state habitat
conservation plan?
✓
Setting
The Coachella Valley is located within the Sonoran Desert, a subdivision of the Colorado Desert. The
Sonoran Desert contains a wide range of biological resources that are highly specialized and endemic to
the region. The central portion of the valley, in which the Project site is located, is composed of sand dunes
and sand fields that are divided into three sub-communities: active sand dunes, active sand fields, and
stabilized and partially stabilized desert sand fields.
99
-32-
A wide range of common plant species, such as mesquite, smoke tree, desert holly, creosote bush, and
palo verde, are supported by the conditions present in the valley, as are a wide range of wildlife species.
Bird species include golden eagle, western burrowing owl, and others. There are also a range of sensitive
plant and animal species present in the Coachella Valley, some of which have been listed as threatened or
endangered by federal and state agencies.
Within the Coachella Valley region, some plant species that are federally listed as endangered include the
Coachella Valley milkvetch and triple-ribbed milkvetch. Threatened or endangered wildlife species
include the Peninsular bighorn sheep, Casey's June beetle, Coachella Valley fringe-toed lizard, arroyo
southwestern toad, and mountain yellow-legged frog. Sensitive bird species include the least Bell’s vireo
and southwestern flycatcher, both listed as endangered. In addition, there are several species of birds
considered “sensitive” by state and federal wildlife resource agencies.
The city is within the boundaries of the Coachella Valley Multiple Species Habitat Conservation Plan
(CVMSHCP), a comprehensive regional plan encompassing approximately 1.2 million acres in the
Coachella Valley that addresses the conservation needs of 27 native flora and fauna species and 27 natural
vegetation communities. The City of Palm Desert is a CVMSHCP Permittee and subject to its provisions.
Discussion of Impacts
a) Less than Significant with Mitigation. The Project site is centrally located within the Living
Desert and surrounding by mature landscaping, wildlife habitat exhibits, and retail/administration
buildings. The proposed site is developed with landscaping and hardscapes for pathways and a
patio area. There are no permanent building structures within the Project footprint. There are
approximately 245 mature trees in the project footprint that will be removed, of which 50 trees
will be salvaged. The Project area contains a mix of native and decorative landscaping, and does
not contain native vegetation communities. A number of common species are expected to currently
occur within the Project area, given the extensive use of landscaped areas and gardens within the
Zoo.
The existing vegetation on-site and adjacent to the site has the potential to provide nesting
opportunities for birds covered under the Migratory Bird Treaty Act (MBTA). Nesting activities
would occur between January and August of any year. Under the provisions of the MBTA, impacts
to covered nesting birds would be considered a significant impact. To assure that impacts to bird
nests covered under the MBTA are reduced to less than significant levels, a pre-construction
survey is required if any activity to remove vegetation is proposed during the nesting season, as
provided in Mitigation Measure BIO.1, below. With implementation of this mitigation measure,
impacts to birds covered by the MBTA will be less than significant.
Burrowing owl is a state species of special concern that resides in open dry grasslands and desert
areas. Since the site is currently developed and centrally located within the Living Desert, the
chance of Burrowing owl being present on-site is negligible. Mitigation is not required.
Development of the expansion Project would not significantly change impacts to biological
resources, because the site has been previously developed and the existing vegetation is
landscaping designed and planted by the Living Desert. Implementation of Mitigation Measure
BIO.1, and adherence to existing federal, state, and City regulations will ensure potential impacts
to sensitive or special status species are reduced to less than significant levels.
100
-33-
b) No Impact. The Project site does not contain any riparian habitat or sensitive natural communities
protected by local plans, the California Department of Fish and Wildlife, or U.S. Fish and Wildlife
Service. The site is centrally located with the Living Desert, and is surrounded by landscaping,
hardscapes, and buildings. Onsite soils have been disturbed by previous grading activity, and
onsite vegetation is limited to palm trees and other desert landscaping. No Project-related impacts
would occur, and no mitigation measures would be required.
c) No Impact. The Project site is located inland and does not contain any streams, marshes, protected
wetlands, or vernal pools protected by the California Department of Fish and Wildlife or U.S. Fish
and Wildlife Service. Project-generated stormwater runoff will be managed onsite and within the
Living Desert (see Hydrology below). No Project-related impacts would occur and no mitigation
measures would be required.
d) Less than Significant with Mitigation. The proposed site is centrally located in the Living Desert.
No natural wildlife corridors or biological linkages are located on the Project site. Surrounding
lands are developed with urban uses, with the exception of the foothills of the Santa Rosa
Mountains to the east, which are separated from the Living Desert by walls and fences. Although
it may provide habitat for migratory birds, the Project site is not identified as a nursery site. As
described above, the site may offer nesting sites for birds protected by the MBTA. Compliance
with pre-construction surveys, described in Mitigation Measures BIO.1 will ensure impacts to
nesting birds are reduced to less than significant levels.
e) No Impact. There are approximately 245 mature trees in the project footprint that will be removed,
of which 50 trees will be salvaged. None of these trees are protected under the Municipal Code.
The proposed Project will not conflict with any local ordinances protecting biological species and
will be required to comply with the landscaping and other applicable requirements of the
Municipal Code and the Living Desert. The Project would also adhere to the City’s General Plan
Policy 4.3 by incorporating native vegetation materials into the Project landscape. No impact will
occur.
f) No Impact. The subject property is within the boundaries of the CVMSHCP, and the City of Palm
Desert is a Permittee to the CVMSHCP. The Project does not propose a land use designation
change that would convert protected or open space lands to urban uses. The CVMSHCP local
development mitigation fee to mitigate impacts to covered species was previously paid when the
Living Desert was first developed, which included the Project site. Therefore, the Project is not
required to pay the development fee. The Project will not conflict with this or any other habitat
conservation plan or natural community conservation plan. No impact will occur.
Mitigation Measures:
BIO.1 Migratory Bird Treaty Act
If ground disturbance or tree or plant removal is proposed between January 15th and August 31st,
a qualified biologist shall conduct a nesting bird survey within 7 to 10 days of initiation of grading
onsite. If active nests are reported, then species-specific measures shall be prepared. At a
minimum, grading in the vicinity of a nest shall be postponed until the young birds have fledged.
For construction that occurs between September 1st and January 31st, no pre-removal nesting bird
survey is required.
101
-34-
• In the event active nests are found, exclusionary fencing shall be placed around the nests until
such time as nestlings have fledged. Avoidance buffers shall be 100 to 300 feet from the nests
of unlisted songbirds, and 500 feet from the nests of birds-of-prey and listed species.
Monitoring:
BIO.A The Project biologist shall supply the City with reports of findings regarding migratory birds. The
reports will be attached to the grading permit for the Project.
Responsible Parties: Project Biologist, City Engineer, Planning Department
Timeline: prior to issuance of any permits that result in ground disturbance
102
-35-
V. CULTURAL RESOURCES
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Cause a substantial adverse change in
the significance of a historical resource
pursuant to § 15064.5?
✓
b) Cause a substantial adverse change in
the significance of an archaeological
resource pursuant to § 15064.5?
✓
c) Disturb any human remains, including
those interred outside of formal
cemeteries?
✓
Setting
The Cahuilla Indians settled in the Coachella Valley centuries ago. They were a Takic-speaking people
that, before European settlement, consisted primarily of hunters and gatherers generally divided into three
groups based on geography: the Pass Cahuilla of the San Gorgonio Pass-Palm Springs area; the Mountain
Cahuilla of the San Jacinto and Santa Rosa Mountains and the Cahuilla Valley; and the Desert Cahuilla
of the eastern Coachella Valley.
The first noted European explorations in the Coachella Valley occurred in the 1820’s. By the 1870’s, non-
native settlements expanded across the region as new federal laws opened lands for settlement. The
discovery of underground water sources increased farming activities in the early 20th century. After World
War II, the Henderson brothers organized the Palm Desert Corporation to promote their new desert town.
In 1946, they started constructing streets and commercial buildings which later became known as Palm
Desert. The City was incorporated in 1973.
The Living Desert was constructed in 1970. The Project site is currently developed with landscaping and
hardscapes include an open-air patio and pathways.
Discussion of Impacts
a) No Impact. The City of Palm Desert Resource Preservation Committee has identified a total of
ten culturally significant sites within the city and designated them historical landmarks. All of
Palm Desert’s registered landmarks are listed in Table 5. Of the ten historically significant
landmarks, only the OWL House is in the vicinity of the Living Desert, less than 1 mile to the
northwest.
103
-36-
Table 5
Palm Desert Register Landmarks
Name Description Location
Historical Society of Palm
Desert/Palm Desert Fire Station
Ranch Vernacular-style building 72861 El Paseo
Shadow Mountain Golf Club First golf course in Palm Desert 73800 Ironwood
Portola Community Center First community library in Palm
Desert
45480 Portola Avenue
Sandpiper Condominiums,
Circle 5-12
Multi-family residential building El Paseo
Palm Desert Community
Church
City of Palm Desert’s first
community church
45630 Cabrillo Portola
Avenue
Schindler House for Marion
Toole
Single-family residences 44870 Cabrillo
Avenue
Randall Henderson House Single-family residence; home of
Randall Henderson, one of the
founders of Palm Desert
74135 Larrea Street
Miles Bates House Famous residential home for its
wave-like roof
73697 Santa Rosa
Way
OWL House Direct influence of Palm Desert’s
modern development aesthetic
47869 Sun Corral
Trail
Kings Points at Palm Desert Multi-family residential
condominium complex designed by
the local architect, Hugh Michael
Kaptur
Cactus & Mesquite Ct
Source: City of Palm Desert Geographic Information System, Cultural Resources Map,
https://www.palmdesert.gov/home/showpublisheddocument/, Accessed March 2024; Historical Society of Palm Desert,
https://michaela169.sg-host.com/?page_id=9, Accessed March 2024.
A significant impact could occur if the proposed Project would disturb historic resources. The
Project is centrally located within the Living Desert and is part of a planned expansion of the Zoo.
The Project site has been developed for 54 years with landscaping and hardscape improvements.
The site is not listed on the California Register of Historical Resources (CRHR) or the National
Register of Historic Places (NRHP). Development of the Project will not impact the OWL House
because the Project is at a distance and Project activities will not occur near it. The OWL House
is not visible from the Project. Therefore, the proposed development is not expected to change or
disturb the existing view of the OWL House. No adverse impacts resulting from the Project are
anticipated.
b) No Impact. Currently, the Project site is developed and consists of landscaping and hardscape.
During the construction phase, no archeological resources are expected to occur because the area
has been disturbed by previous development of the current improvements. Impacts are not
expected.
c) No Impact. No cemeteries or human remains are known to occur onsite. It is unlikely that human
remains will be uncovered during Project development because the site has been previously
developed. However, should human remains be uncovered, California law requires that all activity
cease and the coroner be notified to determine the nature of the remains and whether Native
American consultation is needed. This requirement of law assures that there will be no impact to
cemeteries or human remains.
Mitigation Measures: None.
104
-37-
Monitoring: None.
Sources: California Office of Historic Preservation, Built Environment Resource Directory (BERD), accessed March 2024.
https://ohp.parks.ca.gov/?page_id=30338; National Register of Historic Places, National Park Services. Accessed March 2024.
https://www.nps.gov/subjects/nationalregister/database-research.htm.
105
-38-
VI. ENERGY
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Result in potentially significant
environmental impact due to wasteful,
inefficient, or unnecessary consumption of
energy resources, during project
construction or operation?
✓
b) Conflict with or obstruct a state or local
plan for renewable energy or energy
efficiency?
✓
Setting
Primary energy sources include fossil fuels (e.g. oil, coal, and natural gas), nuclear energy, and renewable
sources (e.g. wind, solar, geothermal and hydropower). Southern California Edison (SCE) provides
electricity to most of the City of Palm Desert, including the Living Desert, and serves approximately 15
million people in a 50,000 square-mile service area.2 Natural gas is provided by the Southern California
Gas Company (SoCalGas). It serves approximately 21.1 million customers in a service area covering
approximately 24,000 square miles.3 Both SCE and SoCalGas offer programs and incentives to reduce
energy consumption.
The Palm Desert Environmental Sustainability Plan (2010) establishes the City’s vision for long-term
energy reduction and sustainability. It addresses city-wide energy usage and establishes goals and policy
recommendations within six resource areas: building efficiency standards, energy management, materials
management, regional air quality, transportation resources, and water management.
Discussion of Impacts
a, b) Less than Significant Impact. The proposed Project will consume energy during both
construction and long-term operation. During construction, energy demand will be primarily
associated with fossil fuels, and will come from the operation of construction machinery and
equipment, manufacturing of construction materials, delivery of building materials, hauling of
construction debris, and commuting of workers to and from the Project site. The Project consists
of typical structures for a commercial use, and has no characteristics that would result in unusually
high use of energy for construction. Construction practices would be subject to current SCAQMD
rules and regulations, such as source-specific standards for engines and limits on equipment idling
duration. The Project would also adhere to state Low Carbon Fuel Standards for construction
equipment and heavy-duty vehicle efficiency standards. These standards would reduce fuel
consumption, help maximize fuel efficiency, and reduce pollutant emissions.
2 Southern California Edison, www.calcities.org/detail-pages/partner/edison, accessed March 2024.
3 SoCalGas, Company Profile, www.socalgas.com/about-us/company-profile, accessed March 2024.
106
-39-
Long-term operational energy demand will be generated by Project lighting, and
heating/ventilation/air conditioning (HVAC) systems. Energy would be consumed during the
operation of the facilities, as well as landscape irrigation, the transport and conveyance of water,
and solid waste hauling and disposal. However, the Project will result in commercial uses typical
of such construction throughout the City and region. Buildings will be constructed in accordance
with the state Building Code, Green Building Code, and Energy Code in effect at the time that
development occurs, to ensure the most efficient building technologies are used, which will benefit
overall building operations, ensure energy efficiency, and reduce wasteful and unnecessary
consumption of energy resources. Current building codes require all newly constructed
commercial buildings to be solar-ready. The Project will be required to comply with these
standards.
The Project will not directly increase the population and will therefore not directly increase vehicle
trips and miles traveled (VMT) and long-term fuel demand. The Environmental Protection Agency
(EPA) and California Air Resources Board (CARB) set forth vehicle fuel efficiency standards to
reduce vehicle emissions. Although the Project will increase vehicle trips, it will not interfere with
increased fuel efficiency standards or result in wasteful, inefficient, or unnecessary consumption
of transportation energy resources during operation.
SCE engages in renewable power generation and procurement, administers a variety of energy
efficiency programs, and encourages rooftop solar energy. According to the Project-specific
CalEEMod analysis (Appendix A), at buildout, the Project is projected to consume approximately
1,345,549 kWh of electricity and approximately 40 therms of natural gas per year. Actual
consumption will be offset by energy-efficient appliances and future solar systems. The Project
will be required to comply with solar requirements of the California Building Code and will not
interfere with any state or local plan that promotes renewable energy or energy efficiency.
Adherence to applicable laws and standards enforced by government agencies, SCE, and
SoCalGas will ensure the Project is consistent with current energy standards and conservation
goals laid out in the City’s General Plan and Environmental Sustainability Plan. Therefore, Project
impacts will be less than significant.
Mitigation Measures: None required.
Monitoring: None required.
Sources: City of Palm Desert General Plan, 2016; City of Palm Desert Environmental Sustainability Plan, February 11, 2010.
107
-40-
VII. GEOLOGY AND SOILS
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Directly or indirectly cause potential
substantial adverse effects, including the risk
of loss, injury, or death involving:
i) Rupture of a known earthquake fault, as
delineated on the most recent Alquist-Priolo
Earthquake Fault Zoning Map issued by the
State Geologist for the area or based on
other substantial evidence of a known fault?
Refer to Division of Mines and Geology
Special Publication 42.
✓
ii) Strong seismic ground shaking? ✓
iii) Seismic related ground failure, including
liquefaction? ✓
iv) Landslides? ✓
b) Result in substantial soil erosion or the
loss of topsoil? ✓
c) Be located on a geologic unit or soil that
is unstable, or that would become unstable
as a result of the project, and potentially
result in on-or off-site landslide, lateral
spreading, subsidence, liquefaction or
collapse?
✓
d) Be located on expansive soil, as defined
in Table 18-1-B of the Uniform Building
Code (1994), creating substantial direct or
indirect risks to life or property?
✓
e) Have soils incapable of adequately
supporting the use of septic tanks or
alternative waste water disposal systems
where sewers are not available for the
disposal of waste water?
✓
f) Directly or indirectly destroy a unique
paleontological resource or site or unique
geologic feature?
✓
Setting
Geology and Soils
The Project is located in the City of Palm Desert which is part of the Coachella Valley. The geology and
seismicity of the Coachella Valley is primarily influenced by the tectonics of the San Andrea and San
Jacinto fault systems. The San Andreas Fault is a continental transform fault that extends roughly 750
miles through California. It forms the tectonic boundary between the Pacific Plate and the North American
Plate, and its motion is right-lateral strike-slip (horizontal). The San Jacinto Fault Zone (SJFZ) is a major
108
-41-
strike-slip fault zone that runs through San Bernardino, Riverside, San Diego, and Imperial Counties in
Southern California. The SJFZ is a component of the larger San Andreas transform system and is
considered to be the most seismically active fault zone in the area.
The Coachella Valley is located in the northwestern portion of the Salton Trough which is bounded by the
San Bernardino Mountains on the northwest, San Jacinto Mountains on the west, Santa Rosa Mountains
on the south, and Little San Bernardino Mountains and Indio Hills on the northeast. Regional soils range
from rocky outcrops within the mountains bordering the valley to coarse gravels of mountain canyons and
recently laid fine- and medium-grained alluvial (stream deposited) and aeolian (wind deposited) sediments
on the central valley floor.
A Geotechnical Investigation report for the Project was prepared by Sladden Engineering January 18,
2024 (see Appendix B). The report evaluated the engineering properties of the subsurface materials to
provide engineering recommendations and design criteria for Project development.
Paleontological Resources
Paleontological resources are the fossilized remains of prehistoric animals and plants, created more than
12,000 years ago in the Pleistocene era. Palm Desert General Plan Policy 9.7 requires development to
avoid paleontological resources whenever possible. If complete avoidance is not possible, development is
required to minimize and fully mitigate impacts to the resource.
Discussion of Impacts
a.i) No Impact. There are no Alquist-Priolo Earthquake Fault Zones in the City (General Plan Figure
8.1), and the subject property is not located within or adjacent to an Alquist-Priolo Earthquake
Fault Zone. The nearest earthquake fault is the Southern Branch of the San Andreas Fault Zone,
approximately 15.2 miles north of the Project site. No fault-related surface rupture would occur on
the Project site.
a.ii) Less than Significant with Mitigation. The Coachella Valley is a seismically active region. The
closest active fault to the City is the San Andreas Fault, 15.2 miles north of the Project site, which
has a maximum event magnitude of 7.2 on the Richter scale. The San Bernardino segment of the
San Andreas Fault is 27 miles west of the City, and has a maximum event magnitude of 7.5 on the
Richter scale. The Project would be exposed to strong ground shaking during a major quake on
nearby faults, which could expose people and structures to safety risks. The impacts associated
with ground shaking could be significant without mitigation.
The Project will be required to comply with the California Building Code (CBC) in effect at the
time that development occurs, which includes seismic safety specifications and requirements. The
Geotechnical Investigation recommended several techniques that will minimize seismic impacts
and reduce them to less than significant levels, including compaction and foundation design. The
Project should be constructed based on parameters for the Site Class D designation. Adherence to
the CBC and recommendations from the geotechnical report will reduce potential impacts
associated with strong seismic ground shaking to less than significant levels on the subject property
(Mitigation Measure GEO.1).
a.iii) No Impact. Seismically induced liquefaction is the loss of soil strength caused by a sudden
increase in pore water pressure shortly after an earthquake. Liquefaction can occur with a
combination of saturated soil or soil below the groundwater table, strong ground shaking, and
109
-42-
susceptible soil types such as loose sands and gravels. Lateral spreading is a form of liquefaction-
related hazard.
According to the Geotechnical Investigation, the depth to groundwater in the Project area exceeds
50 feet. Therefore, risks associated with liquefaction are considered “negligible” and there will be
no impacts.
a.iv) No Impact. The Project site is not susceptible to landslides due to its relatively flat terrain and
distance from mountainous slopes and hillsides at risk of landslides (approximately 0.3 miles)
(Palm Desert General Plan Figure 8.2). No impact will occur.
b) Less than Significant Impact. The Project site is in a high wind erodibility zone (Palm Desert
General Plan Figure 8.3, Wind Erosion Hazard). Buildout of the Project will result in ground
disturbances, including site preparation and grading, that have the potential to increase soil erosion.
However, the Project will include new structures, paved surfaces, and landscaping that will
stabilize ground surfaces and resist long-term erosion. The Project will be required to submit and
implement a site-specific dust control mitigation plan as part of the grading permit process to
minimize potential impacts caused by blowing dust and sand during construction. Adherence to
this standard requirement will assure that potential wind erosion impacts remain less than
significant.
Onsite drainage would be directed to one of two drainage management areas in the Project vicinity
via surface and piped flows. According to the Preliminary Hydrology Report, the Project proposes
retention basins with a combined capacity of 5,098 cubic yards which is sized adequately to contain
the required incremental increase in stormwater runoff, or the implementation of an underground
retention system sized to meet the City’s requirements. Drainage improvements will be required
to implement erosion control Best Management Practices (BMPs) in compliance with City NPDES
Permit requirements, which will ensure that the Project will not result in substantial erosion or
siltation on- or off-site. These include the preparation of a WQMP and a SWPPP. Impacts will be
less than significant.
c) Less than Significant with Mitigation.
Subsidence
Subsidence is the settlement or sinking of the land surface that, in the Coachella Valley, has been
associated with long-term groundwater withdrawal. Subsidence is considered a regional issue and
is being addressed by the water agencies and government agencies through water conservation and
supplemental groundwater recharge efforts. The geotechnical investigation found no fissures or
other surficial evidence of subsidence during site surveys. Nonetheless, adherence to the
recommendations provided in the geotechnical report will assure that impacts regarding
subsidence will remain less than significant (Mitigation Measure GEO.1).
Landslide and Rockfall
See Response VII.a.iv, above.
Liquefaction and Dry Sand Settlement
See Response VII.a.iii, above.
110
-43-
Hydrocollapsible Soils
Hydrocollapsible soils are subject to collapse upon the introduction of water. The volume of
collapsible soils reduces when the pores in the soil become saturated, causing loss of grain-to-grain
contact. Collapsible soils can cause uniform or differential damage to foundations and walls built
on this soil type. Adherence to the recommendations of the geotechnical report will assure that
Project impacts associated with collapsible soils will remain less than significant (Mitigation
Measure GEO.1).
d) Less than Significant Impact with Mitigation. The geotechnical investigation determined
materials underlaying the site consist of Gravelly Sand (SW/SP) and are considered “non-
expansive” soils. Adherence to compaction recommendations of the geotechnical report will
assure that Project impacts associated with expansive soils will remain less than significant
(Mitigation Measure GEO.1).
e) No Impact. The subject property is in an urban area that is served by a community sewer system,
and the proposed Project will be connected to the sewer system. The Project will not result in new
septic tanks or alternative wastewater disposal systems. No impact will occur.
f) No Impact. The soils underlying the Project site have been disturbed by previous development
and consist of gravelly sand that typically does not harbor paleontological resources. The Project
site is currently developed and does not have unique paleontological or geologic features. No
impact will occur.
Mitigation Measures:
GEO.1 The site-specific Geotechnical Investigation report shall be submitted with grading plans, and
report recommendations should be incorporated in Project design and construction.
Recommendation are made on the following topics:
• Earthwork and Grading: Proper site clearing, preparation of building areas soil compaction,
and shrinkage and subsidence control.
• Conventional Shallow Spread Footings;
• Slab-on-Grade uniform foundation supports;
• Retaining wall design;
• Corrosion control;
• Utility trench backfilling;
• Exterior concrete flatwork; and
• Drainage
Monitoring:
GEO.A The applicant shall provide the final grading plan to the Project geotechnical consultant for
review and ensure the recommendations are incorporated into the design criteria and Project
specifications as deemed appropriate by the consultant.
Responsible parties: Project engineer, Project geotechnical consultant, Project applicant.
Sources: City of Palm Desert General Plan, 2016; City of Palm Desert Zoning Map; Geotechnical Investigation for the
Proposed Facilities Expansion – Phase 2.75 and 3.0, The Living Desert,” prepared by Sladden Engineering January 18, 2024
111
-44-
VIII. GREENHOUSE GAS
EMISSIONS
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Generate greenhouse gas emissions, either
directly or indirectly, that may have a
significant impact on the environment?
✓
b) Conflict with an applicable plan, policy or
regulation adopted for the purpose of reducing
the emissions of greenhouse gases?
✓
Setting
Certain gases in the earth’s atmosphere, classified as greenhouse gases (GHGs), play a critical role in
determining the earth’s surface temperature. Prominent GHGs contributing to the greenhouse effect are
carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), and fluorinated compounds. GHGs are emitted
during natural and anthropogenic (human-caused) processes. Anthropogenic emissions of these GHGs in
excess of natural ambient concentrations are responsible for intensifying the greenhouse effect and have
led to a trend of unnatural warming of the earth’s climate, known as global climate change or global
warming.
State laws, such as Assembly Bill 32 (AB 32) and Senate Bill 32 (SB 32), require cities to reduce
greenhouse gas emissions to 1990 levels by the year 2020. SB 32 is the extension of AB 32 and requires
the state to reduce greenhouse gas emissions to 40 percent below 1990 levels by 2030. The City of Palm
Desert adopted an Environmental Sustainability Plan (2010) that is consistent with the goals of AB 32 and
S-3-05, which calls for a statewide GHG emission reduction to 80% below 1990 levels by 2050.
On December 5, 2008, the SCAQMD formally adopted a greenhouse gas significance threshold of 10,000
MTCO2e/yr that only applies to industrial uses’ stationary sources where SCAQMD is the lead agency
(SCAQMD Resolution No.08-35). This threshold was adopted based upon an October 2008 staff report
and draft interim guidance document that also recommended a threshold for all projects using a tiered
approach. It was recommended by SCAQMD staff that a project’s greenhouse gas emissions would be
considered significant if it could not comply with at least one of the following “tiered” tests:
• Tier 1: Is there an applicable exemption?
• Tier 2: Is the project compliant with a greenhouse gas reduction plan that is, at a minimum,
consistent with the goals of AB 32?
• Tier 3: Is the project below an absolute threshold (10,000 MTCO2e/year for industrial projects;
3,000 MTCO2e/year for residential and commercial projects)?
• Tier 4: Is the project below a (yet to be set) performance threshold?
• Tier 5: Would the project achieve a screening level with off-site mitigation?
The analysis provided below is based on this tiered approach.
112
-45-
Discussion of Impacts
a, b) Less than Significant Impact. The proposed Project will generate GHG emissions during both
construction and operation. As described in Section III (Air Quality), the California Emissions
Estimator Model (CalEEMod) Version 2022.1 was used to project the Project’s air quality
emissions, including greenhouse gas emissions (Appendix A). Applicable standard requirements
and best management practices (BMPs) were included in the model, including the implementation
of a dust control and management plan in conformance with SCAQMD Rule 403, phased
application of architectural coatings, and the use of low-polluting architectural paint and coatings
per SCAQMD Rule 1113. Projected short-term construction and annual operational GHG emissions
associated with Project buildout are described below and shown in Table 6.
Construction Emissions
Construction activities, including operation of construction equipment, employee commute, and
material hauling, will generate short-term GHG emissions. As shown in Table 6, the Project is
projected to generate MTCO2e of GHG emissions during the 15-month construction period. There
are currently no construction related GHG emission thresholds for residential projects of this nature.
To determine if construction emissions will result in a cumulatively considerable impact, buildout
GHG emissions were amortized over a 30-year period and added to annual operational emissions
to be compared to applicable GHG thresholds (see Table 6, below).
Operational Emissions
At buildout, there are five emission source categories that will be contributing either directly or
indirectly to operational GHG emissions, including energy/electricity usage, water usage, solid
waste disposal, area emissions (pavement and architectural coating off-gassing), and mobile
sources. Table 6 provides a summary of the projected short-term construction and annual
operational GHG generation associated with buildout of the proposed Project.
Table 6
Projected GHG Emissions Summary (metric
tons/year)
Phase CO2e (MT/YR)
Construction 508
Operational
Area 0.92
Energy 425
Mobile 759
Waste 12.9
Water 16.3
Refrigerants 8.22
Operational Subtotal 1,222.34
Construction, 30-year amortized1 16.93
Total
(30-year amortized construction) 1,239.27
SCAQMD Threshold 3,000.00
1 Buildout construction GHG emissions amortized over 30 years.
508/30 = 16.93. Emission Source: CalEEMod Version 2022.1
113
-46-
Consistency with SCAQMD GHG Thresholds
The proposed Project can be evaluated under SCAQMD’s Tier 3 commercial threshold of 3,000
MTCO2e/year. As shown in Table 6, the Project will emit a total of 1,239.27 tons per year which includes
annual operational emissions and amortized construction emissions and is substantially below the
established threshold of 3,000 tons per year. Therefore, the proposed Project would be consistent with
local, regional and statewide goals and policies aimed at reducing the generation of GHGs. The proposed
Project’s GHG emissions would not constitute a cumulatively considerable contribution, or conflict with
an applicable plan, policy, or regulation for the purposes of reducing the emissions of greenhouse gasses.
Impacts would be less than significant.
Mitigation Measures: None required.
Monitoring: None required.
Sources: Palm Desert General Plan, 2016; CalEEMod Version 2022.1; City of Palm Desert Environmental Sustainability Plan,
February 11, 2010; Palm Desert Greenhouse Gas Inventory, 2008; “California’s 2022 Climate Change Scoping Plan,”
California Air Resources Board, December 2022; Project materials.
114
-47-
IX. HAZARDS AND HAZARDOUS
MATERIALS
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Create a significant hazard to the public or
the environment through the routine
transport, use, or disposal of hazardous
materials?
✓
b) Create a significant hazard to the public or
the environment through reasonably
foreseeable upset and accident conditions
involving the release of hazardous materials
into the environment?
✓
c) Emit hazardous emissions or handle
hazardous or acutely hazardous materials,
substances, or waste within one-quarter mile
of an existing or proposed school?
✓
d) Be located on a site which is included on a
list of hazardous materials sites compiled
pursuant to Government Code Section
65962.5 and, as a result, would it create a
significant hazard to the public or the
environment?
✓
e) For a project located within an airport land
use plan or, where such a plan has not been
adopted, within two miles of a public airport
or public use airport, would the project result
in a safety hazard or excessive noise for
people residing or working in the project
area?
✓
f) Impair implementation of or physically
interfere with an adopted emergency
response plan or emergency evacuation plan?
✓
g) Expose people or structures, either directly
or indirectly, to a significant risk of loss,
injury or death involving wildland fires.
✓
Setting
The proper management of hazardous materials is a common concern for all communities within the
Coachella Valley. Beginning in the 1970s, governments at the federal, state, and local levels became
increasingly concerned about the effects of hazardous materials on human health and the environment.
Numerous laws and regulations were developed to investigate and mitigate these effects. As a result, the
storage, use, generation, transport, and disposal of hazardous materials are highly regulated by federal,
state, and local laws and regulations.
115
-48-
Hazardous waste generators in the City of Palm Desert generally include “small quantity generators,” such
as medical clinics, gasoline service stations, vehicle storage yards, and waste haulers. The City is
responsible for coordinating with the appropriate agencies in the identification of hazardous material sites
and regulation of their timely cleanup.
The Project site is surrounded by the Living Desert attractions and administrative buildings. The site is
currently developed with landscaping and hardscapes. No chemical or hazardous waste disposal has been
documented on the site. There are no known underground tanks or buried materials on the site.
Discussion of Impacts
a, b) Less than Significant Impact. The construction phase of the Project would involve the use of
heavy equipment and vehicles, which will use limited quantities of oil and fuels and other
potentially flammable substances. During construction, equipment could require refueling and
minor maintenance on site that could lead to fuel and oil spills. The contractor will be required to
identify a staging area for storing materials and will be subject to standards and laws regarding the
handling, storage, and use of hazardous materials during construction.
During long-term operation, the Project will involve the routine transport, use, and storage of
cleaning materials for the event center and office use and various chemical products for
landscaping and wildlife exhibit maintenance. None of these products will be used in sufficient
quantities to pose a foreseeable threat to humans or cause a chemical release into the environment.
The use and handling, storage, and disposal of hazardous materials would occur in accordance
with applicable federal, state, and local laws, including California Occupational Health and Safety
Administration (CalOSHA) requirements. Impacts would be less than significant.
c) No Impact. The nearest school is George Washington Charter School on Portola Avenue,
approximately 1 mile north of the Project site. The Project site is not within ¼ mile of a school and
will not use or emit hazardous materials. Therefore, the Project will have no impact associated
with emitting or handling hazardous materials in proximity of a school.
d) No Impact. According to the California Department of Toxic Substances Control EnviroStor
database and the State Water Resources Control Board GeoTracker database, the Project site is not
included on a list of hazardous materials sites compiled pursuant to Government Code Section
65962.5. Therefore, the proposed Project would not create a significant hazard to the public or the
environment. No impact will occur.
e) No Impact. The subject property is not within the boundaries of an airport land use plan or within
2 miles of a public or private airstrip. The site is approximately 10.5 miles from the Palm Springs
International Airport and 6.1 miles from the Bermuda Dunes Airport. Therefore, the Project will
not result in a safety hazard or excessive noise for people in the Project area. No impact will occur.
f) No Impact. The City’s Local Hazard Mitigation Plan was adopted in 2012 and specifies actions
for the coordination of operations, management, and resources during emergencies. Key
evacuation routes include Monterey Avenue, Portola Avenue, Cook Street, and Washington Street
The Project will not physically interfere with emergency response or evacuation plans. It will take
access from Portola Avenue, as the Living Desert does now. The Project will be required to comply
116
-49-
with police and fire department regulations to assure adequate emergency access and vehicle turn-
around space. The inclusion of an exit at the southeast corner of the parking lot specifically for
special event parking will assist the Zoo in managing emergency evacuation from the site, should
it every be necessary. A construction access plan will be required by the City to assure the Project
does not interfere with emergency access during construction. No impacts are expected.
g) Less than Significant Impact. The City’s General Plan Fire Hazard Severity Zones Map
designates portions of Palm Desert’s southern region as a Very High Fire Hazard Severity Zone
(VHFHSZ) based on fuel load, slope, fire weather, and other relevant factors.4 The Living Desert
is in proximity to a high hazard zone and is itself located in a Moderate to High Fire Hazard Zone.
The Project proposes the development of an event center, lion habitat, entry pavilion, and
associated structures located at the center of the park. The City’s Local Hazard Mitigation Plan
(LHMP) assess potential natural hazards, including wildfire, and sets city-specific goals,
objectives, and mitigation strategies to reduce the risk of loss, injury or death involving wildland fires.
The construction and design of the Project will remain in compliance with the local and State
Building Codes regarding fire safety which is comprised of fire prevention features. In addition,
the Project will be inspected prior to operation in order to ensure all fire safety standards are met
at a satisfactory level. For these reasons, impacts are expected to be less than significant.
Mitigation Measures: None required.
Monitoring: None required.
Sources: City of Palm Desert General Plan, 2016; State Water Resources Control Board, GeoTracker, accessed March 2024;
California Department of Toxic Substances Control “EnviroStor” Database, accessed March 2024; City of Palm Desert General
Plan.
4 City of Palm Desert, General Plan, Safety Element, 2016.
117
-50-
X. HYDROLOGY AND WATER
QUALITY
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Violate any water quality standards or waste
discharge requirements or otherwise
substantially degrade surface or ground water
quality?
✓
b) Substantially decrease groundwater supplies
or interfere substantially with groundwater
recharge such that the project may impede
sustainable groundwater management of the
basin?
✓
c) Substantially alter the existing drainage
pattern of the site or area, including through the
alteration of the course of a stream or river or
through the addition of impervious surfaces, in
a manner which would:
(i) result in substantial erosion or siltation on-
or off-site; ✓
(ii) substantially increase the rate or amount of
surface runoff in a manner which would result
in flooding on- or off-site;
✓
(iii) create or contribute runoff water which
would exceed the capacity of existing or
planned stormwater drainage systems or
provide substantial additional sources of
polluted runoff; or
✓
(iv) impede or redirect flood flows? ✓
(d) In flood hazard, tsunami, or seiche zones,
risk release of pollutants due to project
inundation?
✓
(e) Conflict with or obstruct implementation of
a water quality control plan or sustainable
groundwater management plan?
✓
Setting
Domestic Water
The Project site is within the Coachella Valley Water District (CVWD) service area for domestic water.
The District’s primary water source is groundwater extracted through a system of wells from the Coachella
Valley Groundwater Basin. In addition to groundwater, CVWD relies on imported water that is recharged
into the groundwater basin at three facilities: the Whitewater River Groundwater Recharge Facility (GRF),
Thomas A. Levy GRF, and Palm Desert GRF. CVWD’s domestic water system includes 97 groundwater
production wells and 65 enclosed reservoirs. In 2020, it pumped 99,843 acre-feet per year (AFY) of
118
-51-
groundwater from the Indio and Mission Creek Subbasins. CVWD also owns and operates the water
distribution system, which is generally located under existing streets in the public right‐of-way. There are
existing 12- and 30-inch water mains within Portola Avenue in the Project vicinity. The Project will
construct 4-inch water lines throughout the site that will connect to the Living Desert’s existing utility
infrastructure that ultimately connects to Portola Avenue.
CVWD is responsible, under the California Water Code, for analyzing its current and future water supply,
and assuring that sufficient supply is available to serve land uses within the District through the preparation
of an Urban Water Management Plan (UWMP). CVWD is required to periodically update the UWMP. In
2020, CVWD collaborated with other water purveyors in the Coachella Valley to prepare a regional
UWMP.5
Wastewater Treatment
CVWD provides sewer service to the City of Palm Desert, including the Project area. CVWD maintains
sewer trunk lines ranging from 6 to 36 inches in diameter and 28 lift stations and associated force mains.
Effluent from Palm Desert is conveyed to CVWD’s Cook Street treatment plant (Water Reclamation Plant
No. 10), which has a total capacity of 18 million gallons per day (mgd), including 15 mgd of tertiary
treatment capacity. CVWD also implements the requirements of the Regional Water Quality Control
Board pertaining to domestic water quality and wastewater discharge.
The Project site is in an urban area where sewer lines are installed under the main roads. The Project will
construct 6-inch sewer lines throughout the site that will connect to the Living Desert’s existing utility
infrastructure that ultimately connects to the existing 15-inch sewer main on Portola Avenue.
Flood Control
Rainfall on the Coachella Valley floor averages 3 inches annually. Several watersheds drain the mountains
toward the valley floor. There are five stormwater channels in Palm Desert: Whitewater River Stormwater
Channel, Dead Indian Creek, Deep Canyon Channel, Palm Valley System, and East Magnesia Channel.
The Project area is subject to City requirements relating to flood control. The City implements standard
requirements for the retention of storm flows and participates in the National Pollution Discharge
Elimination System (NPDES) to protect surface waters from pollution.
A Preliminary Hydrology Report was prepared by MSA Consulting (June 2023) for the Project and is
provided in Appendix C.
Discussion of Impacts
a) Less than Significant Impact. The Project site is in the Whitewater River watershed. All water
providers in the watershed are required to comply with Regional Water Quality Control Board
(RWQCB) standards for the protection of water quality, including the preparation of project-
specific Water Quality Management Plans (WQMP) for surface waters. CVWD is required to meet
water quality requirements in its production and delivery of domestic water, and its discharge of
waste water.
The Project will connect to the existing CVWD sewer system which will minimize impacts to
regional groundwater quality. Installation of water lines on the Project site will comply with
CVWD and RWQCB standards for water conveyance. The Project will be required to prepare a
5 2020 Coachella Valley Regional Urban Water Management Plan, Water Systems Consulting, Inc., June 30, 2021.
119
-52-
WQMP per the Colorado River Basin Regional Board. To minimize the pollutant load associated
with urban runoff, it will also be required to comply with NPDES regulations, including
preparation of a Storm Water Pollution Prevention Plan (SWPPP). Adherence to conditions of
approval and local, state, and federal standard requirements will assure that the Project will not
violate any water quality standards or waste discharge requirements or conflict with any water
quality control plan or sustainable ground water management plan. Project impacts will be less
than significant.
b) Less than Significant Impact. During construction, water demand will be limited and temporary
and used for dust control purposes, including the routine spraying of ground surfaces and
construction equipment. During operation, water will be used for administrative offices, the event
center kitchen, lion care facility and drought-tolerant landscape irrigation.
The American Water Works Association Research Foundation (AWWARF) has developed
demand factors for land use categories including office and restaurant uses. For analysis purposes,
the event center kitchen (20,620 SF) water demand was calculated using the restaurant demand
factor, and the rest of the event space, lion care facility, and entry pavilion (combined 26,353 SF)
water demand was calculated using general office. As shown in the table below, the Project has
the potential to generate an indoor water demand of 23.76 acre-feet per year.
Table 7
Indoor Water Demand at the Project Buildout
Proposed Land
Use Unit Water Consumption
Factor
Water Demand
(gpd)
Total Water
Demand At
buildout (AFY)
Event Center
Restaurant 20,620 331 gallons/SF/year 18,686.82 20.93
General Office 26,353 35 gallons/SF/year 2,525.32 2.83
Total 23.76
The projected outdoor irrigation water usage is based on the Maximum Applied Water Allowance
(MAWA) equation from Appendix D of CVWD’s Landscape Ordinance No. 1302.5, which meets
the water conservation goals of the California Department of Water Resources (DWR) Model
Efficient Landscape Ordinance (MWELO). The projected outdoor irrigation water demand for the
Project is 6.03 AFY as shown in Table 8, below.
Table 8
Outdoor Water Demand at the Project Buildout
Landscaped
Area (ft2)
ETo
(in/yr) 1 ETAF 2 Conversion
Factor (gal/ft2) 3
Water Demand
(gpd)
Water Demand
(AFY)
119,670 58.87 0.45 0.62 5,385.06 6.03
1 Reference Evapotranspiration (ETo) for ETo Zone 2 from CVWD Landscape Ordinance 1302.5, Appendix C
2 Evapotranspiration Adjustment Factor (ETAF) from CVWD Landscape Ordinance 1302.5, Appendix D
3 Conversion Factor from CVWD Landscape Ordinance 1302.5, Appendix D
According to the 2020 Coachella Valley Regional UWMP6, the projected 2025 regional water
supply is 137,061 AFY, and the projected 2045 regional water supply is 164,966 AFY (UWMP
Table 4-22). Approximately 90% of water supplies are expected to be groundwater and 10% are
6 2020 Coachella Valley Regional Urban Water Management Plan, Water Systems Consulting, Inc., June 30, 2021.
120
-53-
expected to be recycled water. Projections are based on existing water sources and expected future
water supply projects or programs. The proposed Project’s water demand (29.79 AFY) is 0.02%
of projected 2025 regional water supplies and 0.018% of projected 2045 regional water supplies.
Therefore, the Project will not substantially decrease local groundwater supplies or interfere with
groundwater recharge such that it would impede sustainable management of the basin. The Project
includes irrigation requirements, including the use of water-efficient fixtures and drought-tolerant
landscape materials, which will help reduce water demand over the long term. Impacts will be less
than significant.
c) i-iii) Less than Significant Impact. The Project site is generally flat and slopes to the north with an
approximate elevation of 215 feet above sea level. The site is currently developed with landscaping
and hardscapes. The native soil throughout the site consists primarily of fine- to coarse-grained
gravelly sand (SW) and contains no rivers or streams. On-site soils are categorized as hydrologic
soil group A in the National Cooperative Soil Survey and represent well drained to excessively
drained sands or gravelly sands with high infiltration rates (low runoff potential) and high rates of
water transmission.
On-site flows within the Project site typically flow south to north and generally occur as sheet
flow. Mounding on the perimeter of the surrounding areas prevents offsite flows from entering the
project area. The existing parking lot west of the Project site uses a combination of permeable
pavers and storm drain catch basins to percolate storm flows into the ground or convey them to
the existing 66-inch storm drain line running underneath the Project site.
Onsite stormwater runoff will be conveyed via sheet flow and swales to proposed inlets and
subsequently to proposed retention basins. The retention basins are sized to retain the incremental
increase in storm runoff volume from the 100-year storm event, with further runoff being allowed
to continue onto existing or proposed drainage routes within the Living Desert. No new storm
drain facilities will be connected directly to the existing 66” storm drain line which runs north
under the existing parking lot.
The Project will also be required to comply with conditions of approval pertaining to discharge,
standard stormwater management requirements, and project-specific BMPs and a WQMP that are
subject to approval by the City Engineer and required by the City’s NPDES implementation
agreement. Implementation of the WQMP and BMPs will reduce impacts to surface waters by
reducing siltation and reducing or eliminating pollutants in storm flows, including pathogens
(bacteria/virus) generally associated with human activities but also present in the environment.
With the implementation of these measures, impacts associated with surface water pollution will
be less than significant.
Adherence to City requirements, including WQMP BMPs, will ensure the Project will not result
in erosion or siltation on- or off-site. Implementation of these and other applicable requirements
will assure that the Project will not create or contribute water which would exceed the capacity of
existing or planned stormwater drainage systems or provide substantial additional sources of
polluted runoff.
iv) Less than Significant Impact. The Project will manage storm flows within the existing developed
area of the Zoo, and does not propose to modify the topography, or associated storm flows in the
area. The subject property is designated Zone X, which represents areas determined to be outside
121
-54-
the 0.2% annual chance floodplain on FEMA’s Flood Insurance Rate Maps (FIRM). The site is
not located in a 100-year or 500-year FEMA Flood Zone. Implementation of the proposed onsite
drainage and retention facilities will further ensure that the Project will have a less than significant
impact on impeding or redirecting flood flows.
d) Less than Significant Impact. The Project site is inland and not subject to tsunami. It is not in the
vicinity of a water body, levee, or dam. According to the General Plan, the City of Palm Desert is
within the potential inundation area of the Wide Canyon Flood Control Dam in Fun Valley.
However, the dam is managed by the Riverside County Flood Control and Water Conservation
District under state laws to ensure dam safety, and General Plan Policy 3.5 calls for disseminating
information about potential dam inundation areas. No specific dam inundation risk has been
identified for the subject property. The Living Desert is immediately north of two existing water
tanks owned and operated by CVWD. The tanks are subject to strict regulation regarding
reinforcement of these structures, and occur in a depressed area that is bermed on three sides. The
water tanks are reinforced for seismic safety, and do not pose a significant risk of inundation within
the Project area. The Project site is not within a 100-year or 500-year floodplain. Impacts
associated with Project inundation would be less than significant.
e) No Impact. The Project will be required to comply with all applicable water quality standards and
implement a WQMP approved by the city and the RWQCB for both construction activities and
long-term operation. The Project is consistent with the land use designation assigned to the Project
site, and its anticipated water demand is addressed in the 2020 Coachella Valley regional UWMP.
Therefore, it will not conflict with a sustainable groundwater management plan. Adherence to the
City’s standard requirements related to water quality will ensure there will be no impacts to a water
quality control plan.
Mitigation Measures: None required.
Monitoring: None required.
Sources: Preliminary Hydrology Report, The Living Desert Crossroads of Conservation Phase 3, MSA Consulting, Inc, June
23, 2023; 2020 Coachella Valley Regional Urban Water Management Plan, Water Systems Consulting, Inc., June 30, 2021;
FEMA Flood Insurance Rate Map (FIRM) #06065C2228G, revised May 2, 2013; City of Palm Desert General Plan, 2016; City
of Palm Desert General Plan Update & University Neighborhood Specific Plan Draft Environmental Impact Report, 2016 (SCH
2015081020); Project materials.
122
-55-
XI. LAND USE AND PLANNING
Would the project:
Potentially
Significant
Impact
Less Than
Significant w/
Mitigation
Less Than
Significant
Impact
No
Impact
a) Physically divide an established
community? ✓
b) Cause a significant environmental impact
due to a conflict with any land use plan,
policy, or regulation adopted for the purpose
of avoiding or mitigating an environmental
effect?
✓
Setting
Palm Desert is located on the central region of the Coachella Valley and covers 44,533± acres of developed
and undeveloped lands. Under the City’s General Plan, residential, mixed use, commercial, industrial, and
public land uses are grouped into three place types including neighborhoods, centers, and districts. Each
land use designation imposes use, intensity/density, form and character boundaries to ensure that all new
development remains constant with the City’s economic and land use strategy.
The Living Desert is designated Public (P) on the City’s General Plan land use map. The intended use for
public lands is to provide communal spaces consisting of civic centers, libraries, community centers, fire
stations, public/private schools, and similar facilities. The Living Desert is a community focused wildlife
attraction that hosts special events and shows, consistent with its mission of conserving and showcasing
desert wildlife including plant and animal species.
Discussion of Impacts
a) No Impact. The proposed site is centrally located within the Living Desert and is developed with
landscaping and hardscapes including pathways and a patio. The area surrounding the Project site
is fully developed with Living Desert exhibits, administrative and retail buildings, and
landscaping. No residential homes or communities are located onsite or within the Living Desert’s
boundary. The nearest residences (Corsican Villas) are located 350 feet west of the Project area,
beyond Portola Avenue. All residential communities operate independently and will not be divided
by the Project. The Project will not physically divide an established community. There will be no
impact.
b) Less Than Significant Impact. The Project is an amendment to the previous entitlement for the
Living Desert (PP/CUP 15-370), which included a smaller version of the proposed lion habitat and
event center. In addition to the lion habitat and event center, the Project introduces a new entry
pavilion on the north site of the existing Chase building. As part of the Zoo, the Project’s operation
is intended to service existing activities while also providing additional exhibits and services that
remain consistent with the Living Desert’s land use and planned expansion. The Project does not
propose an increase to overall land use densities or development standards currently allowed in
the Public (P) zoning designation.
123
-56-
Among the Project’s goals are expanding the educational and recreational services within the
Living Desert and ensuring high-quality development. It is also consistent with the following
General Plan Land Use Element goals and policies:
Goal 2. Human-Scale Design. A city designed for people, fostering interactions, and safety.
2.3 Landscaping. Require development to incorporate high quality landscaping to
extend and enhance the green space network of the City.
2.6 Lighting. Require all new street lights in commercial areas to be pedestrian-
oriented and scaled, attractively designed, compatible in design with other street
furniture, and to provide adequate visibility and security in accordance with best
practices for night-sky protection.
Overall, the Project’s land uses, development intensity and architecture is consistent with the
originally approved PP/CUP for the property. The planned expansion is consistent with the vision
and goals of the Living Desert and is consistent with the General Plan’s Land Use Element goals
and policies. The Project will not conflict with any land use designation, policy, or regulation
previously approved in relation to the Living Desert. Impacts will be less than significant.
Mitigation Measures: None required.
Monitoring: None required
Sources: City of Palm Desert General Plan.
124
-57-
XII. MINERAL RESOURCES
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Result in the loss of availability of a
known mineral resource that would be of
value to the region and the residents of the
state?
✓
b) Result in the loss of availability of a
locally important mineral resource recovery
site delineated on a local general plan,
specific plan or other land use plan?
✓
Setting
Located at the center of the Coachella Valley, Palm Desert is geographically bound by the Little San
Bernardino Mountains to the north and by the Santa Rosa Mountains to the south. Pursuant to the
California Surface Mining and Reclamation Act of 1975 (SMARA), the state Mining and Geology Board
designates mineral resource sectors within geographic areas where significant mineral resources of
statewide importance and regional significance are located. The City of Palm Desert is in the Palm Springs
Production-Consumption Region that covers approximately 631 square miles of the Coachella Valley
from near Cabazon to Thermal. The city is in Mineral Resource Zone 3 (MRZ-3), defined as “areas
containing known or inferred mineral occurrences of undetermined mineral resource significance.”
Discussion of Impacts
a, b) No Impact. The Project site is in Mineral Resource Zone 3 (MRZ-3). According to the General
Plan EIR, no known mineral sources exist in the city, and the significance of any mineral resource
in MRZ-3 is considered speculative because no mining has historically occurred in the area. The
Project site is not designated, used, or planned for mineral resource extraction or development.
During the geologist’s field investigation specific to the Project, native alluvium sediment was
identified. The native soil encountered throughout the site consists primarily of fine-to-coarse -
grained gravelly sand.7 No significant mineral resources were observed during the field
investigation. Therefore, the Project would have no impact on mineral resources.
Mitigation Measures: None required.
Monitoring: None required.
Sources: City of Palm Desert General Plan (2016); California Department of Conservation, Mineral Land Classification Map,
https://maps.conservation.ca.gov/cgs/informationwarehouse/; Sladden Engineering, Geotechnical Investigation, (2023).
7 Sladden Engineering, Geotechnical Investigation, January 2023.
125
-58-
XIII. NOISE
Would the project result in:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Generation of substantial temporary or
permanent increase in ambient noise levels
in the vicinity of the project in excess of
standards established in the local general
plan or noise ordinance, or applicable
standards of other agencies?
✓
b) Generation of excessive groundborne
vibration or groundborne noise levels? ✓
c) For a project located within the vicinity of
a private airstrip or an airport land use plan
or, where such a plan has not been adopted,
within two miles of a public airport or public
use airport, would the project expose people
residing or working in the project area to
excessive noise levels?
✓
Setting
The predominant source of noise in Palm Desert is motor vehicle traffic. Other noise generators include
light industrial operations, construction activities, commercial activities, and landscaping equipment.
Noise-sensitive receptors include housing, schools, libraries, and senior care facilities. The City has
established goals, policies, and programs to limit and reduce the effects of noise intrusion on sensitive
land uses and to set acceptable noise level standards for various types of land uses.
City Noise Standards
General Plan Table 7.1 (Noise Compatibility Matrix) defines the level of acceptable noise for different
land uses in the city. Normally acceptable noise levels for office buildings, business commercial,
playgrounds and neighborhood park uses is 70 dBA CNEL. The allowable noise levels do not include
construction-related noise levels, as construction activities generate temporary noise. Rather, construction
noise is regulated by Municipal Code Section 9.24.070. General Plan standards are further supplemented
by Municipal Code Section 9.24.030, Sound Level Limits, which regulate noise levels in different land
use zones.
Discussion of Impacts
a) Less than Significant Impact. The subject property is centrally located within the Living Desert
and contains landscaping and hardscapes such as pathways and an outdoor patio. Noise in the
Project area is currently generated from visitors within the park, wildlife exhibits, landscaping
equipment, and mechanical equipment from structures on and off the site (such as HVAC units).
In addition to typical daytime use, the outdoor patio is utilized for large public and private events
such as weddings, dinners, holiday events, and food tasting events. The parking lot is located
approximately 150 feet west of the Project area and is separated from the site by the existing two-
story Chase building. Therefore, vehicle traffic is not a major source of noise for the site. Outside
of the Zoo, the nearest sensitive receptors are residents in multi-family homes approximately 350
feet west of the Project site.
126
-59-
Construction Noise
Project construction will temporarily increase ambient noise levels from the operation of heavy
equipment and machinery. Removal of existing hardscapes and landscaping, grading, construction,
paving, and other development activities will involve the operation of graders, bulldozers, dump
trucks, and similar equipment. Heavy equipment can generate noise levels ranging from 70 to 90
dBA at 50 feet from the source. However, such equipment will be mobile and will not create a
source of constant noise at any one location on the site. In addition, noise levels to sensitive
receptors off-site will be attenuated by distance and the intervening structures within the Living
Desert, including the Chase building and entry pavilion.
Noise from construction activities will be temporary and will cease once the Project is operational.
Construction noise is exempt from the noise standards of Section 9.24.030 of the Municipal Code.
Instead, it is subject to Municipal Code Section 9.24.070, which limits construction activities to
the least sensitive hours of the day, Monday through Saturday, excluding holidays. Adherence to
these restrictions will ensure that construction-related impacts are compatible with the Municipal
Code and less than significant.
Operational Noise
During long-term operation, the Project will permanently increase ambient noise levels in the
Living Desert. Noise will be generated by a marginal increase in visitors, events at the center, the
lion habitat, vehicles accessing the parking lot for large evening events, and mechanical equipment
(such as HVAC units).
The Project is a planned expansion of the Living Desert and noise levels are expected to be
comparable to existing noise levels in the park. During regular daytime business hours, the new
administrative offices and lion exhibit are expected to marginally increase park attendance and
daily vehicle traffic by 122 trips. The proposed event center would increase the frequency of large
weekend events (500 guests), however noise levels are anticipated to be comparable to existing
large events hosted on-site, including both private parties and weddings. In addition, the Living
Desert currently hosts seasonal large parkwide events that occur after regular business hours, such
as Wild Lights and Glow in the Park, that attract more than 500 guests per event. Based on the
operations plan submitted for the Project, events at the new event center would not occur
concurrent with these large public events, so that noise levels would not cumulatively increase.
Finally, the Project is located within the Zoo, and noise emanating from events will be attenuated
by distance and the intervening structures, such as the Chase building, and the structures within
the event space itself. Noise levels, therefore, are not expected to significantly increase, and are
not expected to exceed the City’s CNEL or Noise Ordinance standards.
The Project will be required to comply with the noise level limits of Municipal Code Section
9.24.030. Public Institutional noise levels are limited to 55 dBA between 10 p.m. and 7 a.m., and
65 dBA from 7 a.m. to 10 p.m. The Project is not expected to permanently increase ambient noise
levels such that they exceed the City’s standard of 70 dBA CNEL for office buildings, business
commercial, playgrounds and neighborhood parks. Therefore, Project operational noise will
increase noise levels in the area, but they will not exceed General Plan standards. Impacts will be
less than significant.
127
-60-
b) Less than Significant Impact. Groundborne vibration and/or groundborne noise will be produced
by heavy equipment during the construction phase of the Project. Construction activities, such as
earth-moving and trenching, could generate temporary and short-term groundborne vibration
and/or noise. The highest degree of groundborne vibration is likely to be generated during paving
due to the operation of a vibratory roller. Based on Federal Transit Administration (FTA) data,
vibration velocities from vibratory rollers are estimated to be approximately 0.1980 inch-per-
second PPV at 26 feet from the source of activity. As such, sensitive receptors greater than 26 feet
from vibratory roller operations would not experience groundborne vibration above the Caltrans
significance thresholds (i.e. 0.3 inch-per-second PPV for structures and 0.2 inch-per-second PPV
for human annoyance). The nearest sensitive receptors would be visitors of the park. Due to the
transient nature of the visitors, and the intermittent use of construction equipment, sensitive
receptors would not be significantly impacted by groundborne vibration and/or noise, and any such
impacts would be temporary and would end once construction is complete. Residents on the west
side of Portola are too far distant, based on the attenuation standards described above, to be
significantly impacted by vibration within the Zoo. No such impacts will occur during long-term
Project operation. Therefore, impacts would be less than significant.
c) No Impact. The subject property is not within two miles of any airport, private or public. It is
approximately 10.5 miles from the Palm Springs International Airport and 6.1 miles from the
Bermuda Dunes Airport. No impact would occur.
Mitigation Measures: None required.
Monitoring: None required.
Sources: City of Palm Desert General Plan, 2016; Palm Desert Municipal Code.
128
-61-
XIV. POPULATION AND HOUSING
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Induce substantial unplanned population
growth in an area, either directly (for
example, by proposing new homes and
businesses) or indirectly (for example,
through extension of roads or other
infrastructure)?
✓
b) Displace substantial numbers of existing
people or housing, necessitating the
construction of replacement housing
elsewhere?
✓
Setting
The 2020 U.S. Census counted a total population size of 51,163 for Palm Desert. The Southern California
Association of Governments (SCAG) projects it will grow to 64,100 by 2045. The housing stock includes
36,058 single-family, multi-family, and mobile home units, the majority of which (39.8%) are single-
family detached homes.
Discussion of Impacts
a) No Impact. The Project proposes the development of a new event center, lion habitat, and entry
pavilion within the existing boundaries of the Living Desert. The additional structures are part of
a planned expansion of the Zoo’s operations and are not intended to house temporary or permanent
residents. The Project will not require the expansion of roads or infrastructure, and will rely on
existing facilities and services. For this reason, the Project is not expected to increase the regional
population size because employees and visitors will consist of the local population and out-of-
town guests whose secondary destination is the Zoo. The local population is not expected to
increase as a result of the proposed development and subsequent improvements. No impact will
occur.
b) No Impact. Currently the Project site is developed and located inside the existing footprint of the
Living Desert. No housing units are located within the proposed area. Therefore, the Project will
not displace people or create the need for replacement housing. No impact is anticipated.
Mitigation Measures: None required.
Monitoring: None required.
Sources: 2020-2045 Regional Transportation Plan/Sustainable Communities Strategy (RTP/SCS), Demographics and Growth
Forecast Technical Report, Southern California Association of Governments, adopted September 3, 2020; U.S. Census Bureau,
Palm Desert City, https://data.census.gov/profile/Palm_Desert_City, (Accessed March 2024),
129
-62-
XV. PUBLIC SERVICES
Would the project result in:
Would the project result in substantial
adverse physical impacts associated with
the provision of new or physically
altered governmental facilities, need for
new or physically altered governmental
facilities, the construction of which
could cause significant environmental
impacts, in order to maintain acceptable
service ratios, response times or other
performance objectives for any of the
public services:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
Fire protection? ✓
Police protection? ✓
Schools? ✓
Parks? ✓
Other public facilities? ✓
Setting
Fire Protection
The City contracts fire services from the Riverside County Fire Department (RCFD). The Palm Desert
Fire Department (PDFD) operates three fire stations: Station 71, 33, and 67. Fire Station 55 is operated
by Indian Wells but also maintains a medic unit as part of the Palm Desert’s response system. Each fire
station (apart from Station 55) provides emergency services including fire suppression, emergency
medical services, fire prevention, and natural disaster preparedness services. The Fire Department is
authorized 61 full-time positions, per the contract with Riverside County.8
Riverside County Fire Station 67 at 73200 Mesa View Drive, approximately 0.75 miles west of the Project
site, serves south Palm Desert.
Police Protection
The Palm Desert Police Department (PDPD), under contract with the Riverside County Sheriff’s
Department, provides policing services to a permanent population size of approximately 51,509.
Currently, the Police contract consists of 80 sworn deputy sheriff’s positions and several non-sworn
support positions to assist with the daily operations and field services. The Police Station is located at
73705 Gerald Ford Drive, approximately 5.9 miles north of the Project site.
8 Matrix Consulting Group, Fire Service Delivery Study, Palm Desert, 2021.
https://cityofpalmdesert.granicus.com/MetaViewer.php
130
-63-
Schools
Palm Desert is within the jurisdictions of two school districts: Desert Sands Unified School District
(DSUSD) and Palm Springs Unified School District (PSUSD). The Project site is within the boundary of
the DSUSD. The nearest elementary school is Washington Charter Elementary School on Portola Avenue,
approximately 1 mile north of the Project site.
Parks
The City currently operates and maintains 200 acres of park land in 12 parks. The nearest public park to
the Project site is the Ironwood Park located 0.7 miles west of the Project site.
Other Public Facilities
Other public facilities in Palm Desert include the Palm Desert Library, Joslyn Center (senior services),
City Hall, and other government facilities.
Discussion of Impacts
Fire Protection:
Less Than Significant Impact. The Project will marginally increase the demand for fire services
for the protection of new permanent structures. However, Project development will be in
accordance with all state and local (Municipal Code and RCFD) fire standards, including fire
sprinklers, to assure adequate fire safety and emergency access. The Project will be required to
pay City development impact fees to contribute its fair share of costs for future fire facilities,
personnel, and apparatus. Therefore, Project impacts will be less than significant.
Police Protection:
Less Than Significant Impact. The Project is part of a planned expansion of uses within the
Living Desert and is not anticipated to increase the demand for police protection services above
existing levels. Nonetheless, the Project will be required to comply with all Police Department
regulations and procedures, and Project plans will be reviewed by the Police Department to assure
adequate emergency access is provided. The Project is not expected to require the construction of
new or expanded police services or facilities. Impacts will be less than significant.
Schools:
No Impact. The Project site is within the Desert Sands Unified School District (DSUSD)
boundary. The Project is part of a planned facilities expansion within the Living Desert and does
not propose uses that would increase the City’s population. The Project may be required to pay the
standard DSUSD developer fees in place at the time development occurs, which are currently
$0.78 per square foot of commercial development.9 There will be no impact.
Parks/ Other Public Facilities:
No Impact. The Project is not expected to increase the City’s population size that would degrade
or impact the access to or physical conditions of local parks because potential new employees will
primarily consist of the local population. The Project does not warrant the expansion or
9 Fee Schedule, Palm Springs Unified School District website, www.psusd.us, accessed March 2024.
131
-64-
construction of parks to adequately service the public. No environmental impacts related to
development of public parks will occur.
Mitigation Measures: None required.
Monitoring: None required.
Sources: City of Palm Desert General Plan, 2016; DSUSD Developer Fee Schedule; Project materials.
132
-65-
XVI. RECREATION
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Would the project increase the use of
existing neighborhood and regional parks or
other recreational facilities such that
substantial physical deterioration of the
facility would occur or be accelerated?
✓
b) Does the project include recreational
facilities or require the construction or
expansion of recreational facilities which
might have an adverse physical effect on the
environment?
✓
Setting
The Palm Desert Parks and Recreational Department oversees the management and operation of more
than 200 acres of park land, two community centers, an Aquatic Center, and over 25 miles of multi-
purpose hiking trails.10 These facilities are open and accessible to the public.
The nearest recreational facility is the City of Palm Desert Ironwood Park, located approximately 0.70
miles west of the Living Desert. Palm Desert City Hall, located at 73510 Fred Waring Drive, is ± 2 miles
to the northwest. Palm Desert Community Center, located at 43900 San Pablo Avenue, is ± 2.30 mile to
the northwest, and the Homestead Trailhead, located on the foothills of San Rosa Mountains along Thrust
Road, is 1.50 miles west of the Zoo.
Discussion of Impacts
a, b) Less Than Significant Impact. The Project is not expected to increase the City’s population size
because potential new employees will primarily consist of the local population. No non-resident
is expected to relocate to Palm Desert as a result of the Project construction or long-term operation.
The Project in and of itself is an expansion of an existing public attraction that includes recreational
facilities. Therefore, the Project will not contribute to the physical deterioration of these facilities,
but instead provide improvements and diversify the recreational uses.
The local population will continue to have access to open space and community-oriented facilities
without a direct impact from the Project. For this reason, the Project does not warrant the need for
the expansion of existing or construction of new recreational facilities outside of the Living Desert
to adequately accommodate the public. Impacts are less than significant.
Mitigation Measures: None required.
Monitoring: None required.
Sources: City of Palm Desert General Plan.
10 City of Palm Desert, Parks and Recreation, https://www.palmdesert.gov/departments/parks-recreation, Accessed March
2024.
133
-66-
XVII. TRANSPORTATION
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Conflict with a program plan, ordinance or
policy addressing the circulation system,
including transit, roadway, bicycle and
pedestrian facilities?
✓
b) Would the project conflict or be
inconsistent with CEQA Guidelines section
15064.3, subdivision (b)?
✓
c) Substantially increase hazards due to a
geometric design feature (e.g., sharp curves
or dangerous intersections) or incompatible
uses (e.g., farm equipment)?
✓
d) Result in inadequate emergency access? ✓
Setting
Existing Conditions
The Project site is centrally located within the Living Desert which currently generates traffic from visitors
and employees of the Zoo. The Palm Desert General Plan Mobility Element establishes a roadway
classification system based on vehicle capacity, number of lanes, and other improvements such as bike
lanes, sidewalks, and parkways. Portola Avenue is classified as a Secondary Street adjacent to the Living
Desert (General Plan Figure 4.1), consisting of a 4-lane divided roadway with a median and bicycle and
pedestrian facilities, but is striped for one lane in each direction at this location. Secondary Streets are
designed to accommodate 30,000 vehicles at Level of Service (LOS) C. The General Plan (Figure 4.2)
designates Portola Avenue as a Class 2 (on-street striped lane) bicycle and golf cart facility adjacent to
the Living Desert.
SunLine Transit Agency provides bus transit services to the Coachella Valley, including Palm Desert.
Currently, there are no transit routes or facilities in the immediate Project vicinity. The nearest bus stop is
on Portola and Highway 111, approximately 1.4 miles north of the Project site, which can be accessed via
existing sidewalks and bike lanes.
Level of Service Threshold
The General Plan does not set forth a LOS threshold for acceptable roadway and intersection operations.
Policy 1.3 of the Mobility Element states that the City will “determine appropriate service levels for all
modes of transportation and develop guidelines to evaluate impacts to these modes for all related public
and private projects.” The city has not yet developed new guidelines for an acceptable LOS. The city has
adopted the County of Riverside Transportation Analysis Guidelines for Level of Service & Vehicle Miles
Traveled (County of Riverside Department of Transportation, December 2020) for transportation analysis.
134
-67-
VMT Analysis
Effective July 1, 2020, the California Environmental Quality Act (CEQA) Guidelines require lead
agencies to adopt Vehicle Miles Traveled (VMT) as a replacement for automobile delay-based LOS as
the measure for identifying transportation impacts for land use projects. The city has adopted the County
of Riverside Transportation Analysis Guidelines for Level of Service & Vehicle Miles Traveled (County
of Riverside Department of Transportation, December 2020) for Level of Service & Vehicle Miles
Traveled.”
A Trip and Parking Generation Analysis was prepared for the Project in 2023, and can be found in
Appendix D.
Discussion of Impacts
a) Less Than Significant Impact. The Project is a planned expansion of the Living Desert that
includes a 41,240 SF event center and administration building, a 1,282 SF entry pavilion, and lion
habitat exhibit with a 4,451 SF lion care facility and associated shade and viewing structures. The
Project does not require modifications to the park’s access points or additional parking. The Living
Desert is currently accessed from one main drive on Portola Avenue. A secondary exit point south
of the main entrance, also on Portola Avenue, will be utilized during special events and will be a
right-turn exit only. The proposed expansion requires the removal of 1 ADA parking space for the
new entry pavilion, resulting in 19 ADA parking spaces for a parking total of 936 spaces.
Table 9 shows the projected trips associated with daily operations of the new administration and
lion habitat uses, and trips associated with a large event (500 people). As shown in the table, the
Project is forecast to generate approximately 122 additional daily vehicle trips during regular
business hours at buildout, including 17 trips during the AM peak hour and 16 trips during the PM
peak hour. A large event would generate approximately 375 additional trips per event, including
170 trips for “event inbound” peak hour and 68 trips for “event outbound” peak hour.
135
-68-
Table 9
Project Trip Generation Summary
Trip Generation Rates – Daily1
Land Use ITE Code
Unit
AM Peak Hour PM Peak Hour
Daily In Out Total In Out Total
Office 710 TSF2 1.34 0.18 1.52 0.26 1.18 1.44 10.84
Project Trips Generated
Land Use
Quantity
Unit
AM Peak Hour PM Peak Hour
Daily In Out Total In Out Total
Office 11,3003 TSF 15 2 17 3 13 16 122
Trip Generation Rates – Large Special Event (500 Guests)
Land Use ITE Code Unit Event Inbound Peak Hour Event Outbound Peak Hour Daily
(Event) In Out Total In Out Total
Event Venue Project-Specific Guest 0.34 0 0.34 0 0.14 0.14 0.75
Event Trips Generated
Land Use Quantity Unit Event Inbound Peak Hour Event Outbound Peak Hour Daily
(Event) In Out Total In Out Total
Event Venue 500 Guest 170 0 170 0 68 68 375
Total Daily Plus Large Event 497
1 Source: Institute of Transportation Engineers (ITE) Trip Generation Manual, 11th edition, 2021.
2 TSF = thousand square feet
3 11,300 SF includes the 2nd floor office space in the event center, entry pavilion and lion habitat.
The two major intersections nearest to the Living Desert are along Portola Avenue at El Paseo and
Highway 111, approximately 1.2 and 1.3 miles north of the site, respectively. According to the
2016 General Plan Update EIR11, both intersections would be operating at an acceptable Level of
Service (C) at buildout (2040), which includes operation of the Living Desert. The event space
will generate sporadic traffic which will not add to the regular daily peak hour congestion on City
streets, because the events will occur during off-peak times, including evenings and weekends.
The Project is part of the planned expansion of the Living Desert that was considered in the 2016
General Plan EIR, and as demonstrated in Table 9 would not significantly increase the number of
daily trips in the area. The Project does not propose changes to the existing circulation system.
Therefore, the Project would not have a significant impact on the City’s circulation system.
A preliminary parking analysis was prepared for the Project demonstrating the Living Desert has
adequate parking supply to accommodate planned events, as shown in Table 10. This is assuming
no events during special events such as Wild Lights and Glow in the Park, and no events during
the Park’s peak, which occurs at 11:00 AM, on the 10-15 busiest days of the year. Since parking
demand, even on busy days, begins to drop-off after 12:00 PM, minor and medium events (up to
250 guests) could be allowed at/after 1:00 PM, without negatively impacting parking capacity, as
shown in the Table.
11 Table 4.15-23 Buildout (2040) Intersection Level of Service: Palm Desert. Palm Desert General Plan Update and
University Neighborhood Park Specific Plan Environmental Impact Report. Michael Baker International. August 2016.
136
-69-
Table 10
Project Parking Analysis
Scenario
Parking Demand Parking
Zoo/
Gardens
Project Admin/
Lion Care
Project
Event Total Supply
Typical Day at Zoo Plus Project, 11AM No Event 642 10 0 652 936
Typical Day at Zoo Plus Project, 11 AM Max Event 642 10 275 927 936
Typical Day at Zoo Plus Project, 4:30 PM Max Event 186 10 275 471 936
Busy Day at Zoo Plus Project, 11AM No Event 895 10 0 905 936
Busy Day at Zoo Plus Project, 1 PM Medium Event 691 10 138 839 936
Busy Day at Zoo Plus Project, 4:30 PM Wedding 400 10 275 685 936
Alternative Transportation
The Project is wholly located within the boundaries of the Living Desert. Existing on-street shared
bike and golf cart lanes are located on both sides Portola Avenue in proximity to the Living Desert.
The Project does not propose modifications to the City’s bicycle routes along Portola Avenue.
Transit service in the City is provided by SunLine Transit Agency. The Project site is not currently
served by a SunLine route. The nearest bus stop to the Project site is located along Highway 111,
approximately 1.3 miles north of the Project site. SunLine periodically reviews and updates its
services and facilities based on ridership, budget, and community demand. General Plan Mobility
Element Goal 5 and Policies 5.1 through 5.6 promote and encourage public and private transit
service and connections to bicycle and pedestrian networks. The Project would have no impact on
plans or policies addressing transit facilities.
b) No Impact. CEQA Guidelines section 15064.3 sets forth guidelines for implementing Senate Bill
743 (SB 743). SB 743 requires amendments to the CEQA Guidelines (pre-2019) to provide an
alternative to LOS for evaluating transportation impacts. Particularly within areas served by
transit, those alternative criteria must “promote the reduction of greenhouse gas emissions, the
development of multimodal transportation networks, and a diversity of land uses.” (Public
Resources Code Section 21099(b)(1).) Measurements of transportation impacts may include
“vehicle miles traveled, vehicle miles traveled per capita, automobile trip generation rates, or
automobile trips generated.”
The CEQA Guidelines have since been updated to allow for lead agency discretion in establishing
methodologies and thresholds consistent with the intent of the legislation. The City utilizes the
December 2020 County of Riverside Transportation Guidelines for VMT assessments. Per County
guidelines, a project would have a less than significant VMT impact if:
• Small projects (less than 110 daily trips);
• Projects near high quality transit;
• Local serving retail;
• Affordable housing;
• Local essential service (day care, police or fire facility, medical/dental office, government
office);
• Residential and office projects in an area under VMT thresholds as shown on screening
maps (Low VMT Area); and
• Redevelopment projects.
137
-70-
The County Guidelines indicate that “small projects” that generate fewer than 110 daily vehicle
trips are presumed to have a less than significant impact absent substantial evidence to the contrary.
In addition, “small projects” are anticipated to generate low traffic volumes and as a result assumed
to generate greenhouse gas (GHG) emissions less than 3,000 MTCO2e per year. While the Project
would generate 122 daily trips, which is 12 trips more than the “small project” threshold of 110
trips, the Project would generate less than 3,000 MTCO2e annually. According to Table 6 of this
Initial Study, under Section VIII Greenhouse Gas Emissions, the Project is projected to emit
1,239.27 MTCO2e per year which includes annual operational emissions and amortized
construction emissions and is substantially below the threshold of 3,000 tons per year. Therefore,
the Project is consistent with the intent of the “small projects” definition and will not conflict with
or be inconsistent with CEQA Guidelines section 15064.3, subdivision (b).
c) No Impact. The Project does not propose changes to the Living Desert’s access or circulation
except for the removal of 1 ADA parking space for improvements at the proposed north entryway
pavilion. No sharp curves, dangerous intersections, or hazardous geometric features are proposed.
The Project vehicle mix will be consistent with the existing mix in the Project area. Construction
plans will be coordinated with the city so that construction activity does not interfere with traffic
on adjacent and nearby roads.
d) No Impact. The Project does not propose changes to emergency access. Prior to construction, the
Fire and Police Departments will review the site plan to ensure safety measures are addressed,
including emergency access and vehicle turnaround space. Construction plans will be coordinated
with the city and emergency providers, as needed, to assure that emergency access is maintained
throughout all stages of development. No impact will occur.
Mitigation Measures: None.
Monitoring: None.
Sources: City of Palm Desert General Plan, 2016; City of Palm Desert General Plan Update & University Neighborhood
Specific Plan Draft Environmental Impact Report, August 2016 (SCH 2015081020); “The Living Desert Phase 3 Project –
Preliminary Trip and Parking Generation Analysis,” prepared by Walker Consultants. October 25, 2023.
138
-71-
XVIII. TRIBAL CULTURAL
RESOURCES
a) Would the project cause a substantial
adverse change in the significance of a
tribal cultural resource, defined in Public
Resources Code section 21074 as either a
site, feature, place, cultural landscape
that is geographically defined in terms of
the size and scope of the landscape,
sacred place, or object with cultural
value to a California Native American
tribe, and that is:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
i) Listed or eligible for listing in the
California Register of Historical Resources,
or in a local register of historical resources as
defined in Public Resources Code section
5020.1(k), or
✓
ii) A resource determined by the lead
agency, in its discretion and supported by
substantial evidence, to be significant
pursuant to criteria set forth in subdivision
(c) of Public Resources Code Section
5024.1. In applying the criteria set forth in
subdivision (c) of Public Resources Code
Section 5024.1, the lead agency shall
consider the significance of the resource to a
California Native American tribe.
✓
Setting
The Cahuilla people lived in the Coachella Valley for thousands of years. They were Takic-speaking and
lived in various groups in the region. Today, Native Americans of Pass or Desert Cahuilla heritage are
mostly affiliated with one or more of the Indian reservations in and near the Coachella Valley, including
the Cabazon, Augustine, Torres Martinez, Twenty-nine Palms, Agua Caliente, and Morongo. Numerous
cultural resources are found throughout the valley which provide important information about the past.
Discussion of Impacts
a. i, ii) Less Than Significant Impact. Assembly Bill 52 (AB 52) requires a lead agency to consult with
tribes in the Project area during the CEQA process to allow tribes to be involved in the project
development process and to address their concerns about potential impacts to tribal cultural
resources. The consultation process requires Palm Desert to provide written notification about a
proposed project, as defined by CEQA, to tribes within the project’s geographic area. If a tribe
chooses to engage in consultation, it must respond to the lead agency within 30 days of receipt of
the formal notification, and the lead agency must begin the consultation process within 30 days of
receiving the request for consultation. Consultation concludes when the parties agree to measures
139
-72-
to mitigate or avoid a significant effect (if a significant effect exists) on the tribal cultural resources,
or when a party, acting in good faith and after reasonable effort, concludes that mutual agreement
cannot be reached (Public Resources Code section 21080.3.2 (b)(1) and (2)).
The city initiated the tribal consultation process in conformance with AB 52 requirements. It
distributed consultation letters to the tribes who have requested consultation under AB 52. The
City received a letter from the Agua Caliente Band of Cahuilla Indians (ACBCI), requesting
consultation. The Tribe also requested copies of cultural resource reports and records, and the
presence of a Tribal Monitor during earth moving activities. The City held a telephone consultation
meeting with the Tribe, which reiterated that because there was no previous record of cultural
surveys on the Project site, a Tribal Monitor would be required to assure that no buried resources
are uncovered during grading and excavation. This request is reflected in Mitigation Measure
TCR-1 below.
Mitigation Measures:
TCR-1 Prior to the issuance of any ground disturbing permit on the site, the applicant shall provide the
City with a fully executed Monitoring Agreement with ACBCI, providing for a Tribal Monitor’s
presence during earth moving activities. The Tribal Monitor shall have the authority to temporarily
stop construction if buried resource(s) are found, but shall quickly determine the significance of
the find, whether a qualified archaeologist must be brought to the site to investigate the find, and
how it must be treated. Any resources recovered shall be professionally documented and deposited
and curated in a professional depository. The Tribal Monitor shall be responsible for providing the
City a report of findings.
Monitoring:
TCR-A The applicant shall provide the City with a Monitoring Agreement with ACBCI.
Responsible Party: Applicant, City Planning Department
Timing: Prior to any ground disturbance.
TCR-B The Tribal Monitor and/or archaeologist shall provide the City with a report of findings.
Responsible Party: Tribal Monitor, City Planning Department
Timing: Within 30 days of completion of monitoring activities.
Sources: Consultation letters and responses.
140
-73-
XIX. UTILITIES AND SERVICE
SYSTEMS
Would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Require or result in the relocation or
construction of new or expanded water,
wastewater treatment or storm water
drainage, electric power, natural gas, or
telecommunications facilities, the
construction or relocation of which could
cause significant environmental effects?
✓
b) Have sufficient water supplies available
to serve the project and reasonably
foreseeable future development during
normal, dry and multiple dry years?
✓
c) Result in a determination by the
wastewater treatment provider which serves
or may serve the project that it has adequate
capacity to serve the project’s projected
demand in addition to the provider’s existing
commitments?
✓
d) Generate solid waste in excess of State or
local standards, or in excess of the capacity
of local infrastructure, or otherwise impair
the attainment of solid waste reduction
goals?
✓
e) Comply with federal, state, and local
management and reduction statutes and
regulations related to solid waste?
✓
Setting
Domestic Water
The Project site is within the Coachella Valley Water District (CVWD) service area for domestic water.
Its primary water source is groundwater extracted through a system of wells from the Whitewater River
subbasin. In addition to groundwater, CVWD relies on imported water brought to the region by canals.
CVWD’s domestic water system includes 97 wells with a total daily pumping capacity of 244 million
gallons. CVWD has a total of 64 reservoirs, with an average storage capacity of 153.2 million gallons.
CVWD also owns and operates the water distribution system, which is generally located under existing
streets in the public right‐of-way. There are existing 12- and 30-inch water mains within Portola Avenue
in the Project vicinity. The Project will construct 4-inch water lines throughout the site that will connect
to the Living Desert’s existing utility infrastructure that ultimately connects to Portola Avenue.
CVWD is responsible, under the California Water Code, for analyzing its current and future water supply
and assuring that sufficient supply is available to serve land uses within the District, through the
preparation of an Urban Water Management Plan (UWMP). CVWD is required to periodically update the
Plan.
141
-74-
Wastewater Treatment
The Coachella Valley Water District (CVWD) also provides sewer service to the City of Palm Desert,
including the Project area. The Project site is in an urban area where the main sewer lines were laid out
under the main roads and streets. The Project will construct 6-inch sewer lines throughout the site that will
connect to the Living Desert’s existing utility infrastructure that ultimately connects to the existing 15-
inch sewer main on Portola Avenue.
CVWD maintains sewer trunk lines ranging in size from 4- to 24-inches and five sewer lift stations in City
boundaries. Effluent from the City is conveyed to CVWD’s Cook Street treatment plant (Water
Reclamation Plant No. 10), which has a total capacity of 18 million gallons per day (mgd), including 15
mgd tertiary treatment capacity. CVWD also implements the requirements of the Regional Water Quality
Control Board (RWQCB) pertaining to domestic water quality and wastewater discharge.
Stormwater Management
Several watersheds drain the elevated terrain of the San Jacinto, Santa Rosa, San Bernardino, and Little
San Bernardino Mountains towards the valley floor. There are five stormwater channels in Palm Desert:
the Whitewater River Stormwater Channel and its tributaries, including Dead Indian Creek, the Deep
Canyon Channel, the Palm Valley System, and the East Magnesia Channel. For the proposed Project,
management of stormwater is under the jurisdiction of the cities of Palm Desert and Indian Wells.
Electric Power and Natural Gas
Southern California Edison (SCE) provides electrical services to the City of Palm Desert. Natural gas is
provided by the Southern California Gas Company (SoCalGas). There are underground lines to the west
of the Project site.
Solid Waste
Burrtec Waste and Recycling Services, LLC (Burrtec) provides solid waste disposal to the city through a
franchise agreement. Non-hazardous household, commercial, and most nonhazardous industrial solid
waste collected is taken to the Edom Hill Transfer Station (EHTS) in Cathedral City, which is permitted
to receive 3,500 tons of waste per day. From there, solid waste is transported to the Lamb Canyon regional
landfill, which is operated by the County of Riverside and had a remaining capacity of 19,242,950 cubic
yards as of 2015 (latest available data).
Discussion of Impacts
a-c) Less than Significant Impact.
Water
The subject property is within the jurisdiction of the Coachella Valley Water District (CVWD) for
domestic water services. The Project proposes 4-inch water mains to connect to existing 4- and
12-inch water mains are already in place and operational in under the Living Desert, with ultimate
connection to 12- and 30-inch mains beneath Portola Avenue. No new water infrastructure other
than on-site extensions will be required which could result in significant environmental effects.
142
-75-
The 2020 Coachella Valley Regional Urban Water Management Plan (UWMP) demonstrates that
CVWD has available, and can supply in the future, sufficient water to serve additional
development in its service area. The UWMP calls for a combination of continued groundwater
extraction, conservation programs, additional water sources and source substitution, and
groundwater recharge opportunities. CVWD anticipates having sufficient water supplies to serve
existing and future in the near-term (2025) and long-term (2045). For 2025, projected water supply
is 137,061 AFY and retail water demand is 123,461 AFY, resulting in an anticipated surplus of
13,600 AFY. For 2045, projected water supply is 164,966 AFY and retail water demand is 148,166
AFY, resulting in an anticipated surplus of 16,800 AFY (UWMP Tables 4-8 and 4-22). Future
demand projections are based on development intensities provided in the General Plans of regional
jurisdictions, including the Palm Desert General Plan and University Neighborhood Specific Plan
(UNSP). The Project is part of the planned expansion of the Living Desert and proposes an event
center, lion habitat exhibit and entry pavilion.
As discussed in Section X (Hydrology and Water Quality) of this Initial Study, the Project’s
projected annual water demand at buildout is approximately 29.79 acre-feet, which is 0.02% of
2025 projected water supply and 0.018% of 2045 projected water supply. Therefore, CVWD has
available, or can supply, sufficient water to serve reasonably foreseeable development, including
the proposed Project. Additionally, CVWD has determined that it will be able to meet future urban
water demands projected in the regional UWMP in normal, single dry, and multiple dry years
(UWMP Tables 4-25, 4-26, 4-27). Project water consumption will be reduced with low-flow
appliances, water-efficient irrigation practices, and drought-tolerant landscape materials. Impacts
to water supplies will be less than significant.
Wastewater
The subject property is within the jurisdiction of CVWD for wastewater collection and treatment
services. Existing sewer infrastructure is already in place and operational in the Project area. The
Project will connect to existing 6-inch sewer lines beneath Living Desert and will install new 6-
inch sewer lines onsite. Sewage will be conveyed to and treated at Water Reclamation Plant-10
(WRP-10) on Cook Street in Palm Desert. WRP-10 treats wastewater from four cities (Palm
Desert, Indian Wells, Rancho Mirage, and portions of Cathedral City) and serves a population of
approximately 90,000 people. It has a secondary treatment capacity of 18 million gallons per day
(mgd) and currently treats an average daily flow of approximately 9 mgd.12 WRP-10 also has a
tertiary treatment capacity of 15 mgd and supplies tertiary treated water for golf course and
landscape irrigation. Therefore, the plant has sufficient capacity to serve additional development,
including the proposed Project. Project wastewater discharges will be typical of the Living Desert
uses and will not exceed wastewater treatment requirements of the CVWD or Regional Water
Quality Control Board. Other than onsite extensions, no new sewer infrastructure will be required
which could result in significant environmental effects. Impacts to wastewater services will be less
than significant.
12 2020 Coachella Valley Regional Urban Water Management Plan, Water Systems Consulting, Inc., June 30, 2021, Table
4-16.
143
-76-
Stormwater Drainage
There is an existing 66” storm drain line which runs north under the existing Living Desert parking
lot. The Project site is currently developed with landscaping and impervious surfaces. The
proposed Project would result in a comparable mix of impervious surfaces and stormwater flows.
Mounding on the perimeter of the Living Desert prevents off-site flows from entering the Zoo and
Project area. On-site flows within the Project site typically flow south to north and generally occur
as sheet flow. Stormwater runoff will be conveyed via sheet flow and swales to proposed inlets
and subsequently to proposed retention basins. The retention basins will be sized to retain the
incremental increase in storm runoff volume, with further runoff being allowed to continue onto
existing or proposed drainage routes. The Project does not require the construction or expansion
of stormwater management facilities that could result in significant environmental impacts.
Impacts will be less than significant.
Electricity
The Project will provide local connections to the existing SCE infrastructure in the Project area.
SCE has existing facilities underground within Portola Avenue. The Project will not require the
addition or expansion of electric power facilities.
Natural Gas
The Project will provide local connections to the existing SoCalGas infrastructure within Portola
Avenue. Other than onsite connections, the Project will not require the addition or expansion of
natural gas facilities. Impacts will be less than significant.
Telecommunications
The Project will require local connections to the existing Frontier Communications and Spectrum
infrastructure in the Project area. Existing underground communications cables are available
within Portola Avenue. Other than on-site connections, the Project will not require the addition or
expansion of telecommunication facilities. Impacts will be less than significant.
d, e) Less than Significant Impact. Burrtec provides solid waste services to the City of Palm Desert.
Solid waste is recycled, reused, or transformed at a waste-to-energy facility13, or disposed of at
County landfills. The Lamb Canyon regional landfill has a remaining capacity of 19,242,950 cubic
yards as of 2015 (latest data available).14
As shown in the following table, the Project would develop 46,973 square feet of
public/institutional space and generate an estimated 30 tons of solid waste per year. This equals
240 cubic yards per year15, which is approximately 0.0012% of the Lamb Canyon landfill’s
remaining capacity. Therefore, the Project will not exceed the available capacity of the landfill and
Project impacts will be less than significant.
13 Riverside County Nondisposal Facility Element by Riverside County Department of Waste Resources (2015, amended
2023), https://rcwaste.org/sites/g/files/aldnop376/files/2023-
11/2023%20Update%20Non%20Disposal%20Facility%20Element%20NDFE.PDF.
14 CalRecycle SWIS Facility/Site Activity Details.
https://www2.calrecycle.ca.gov/SolidWaste/SiteActivity/Details/2246?siteID=2368 , accessed March 2024.
15 Assumes 1 cubic yard of residential uncompacted municipal solid waste equals 250 lbs. “Volume-to-Weight Conversion
Factors,” US EPA Office of Resource Conversion and Recovery, April 2016.
144
-77-
Table 11
Estimated Solid Waste Disposal at Buildout
Proposed Land
Use Disposal Rate* Proposed
Units (SF)
Solid Waste
Disposal
(lbs/day)
Projected Solid
Waste Disposal
(tons/year)
Public/Institutional 0.007 pounds/square
feet/day 46,973 328.81 60
Total (with 50% diversion): 30
*Estimated Solid Waste Generation Rates by CalRecycle,
https://www2.calrecycle.ca.gov/WasteCharacterization/General/Rates , accessed March 2024.
Recyclable materials (e.g., paper, plastic, glass, cardboard, aluminum) will be transported to
Burrtec’s material recovery facilities for recycling and reuse. Burrtec is responsible for
maintaining standards that assure that all waste is handled in a manner that meets local, state, and
federal standards. These requirements will assure that impacts associated with solid waste disposal
remain less than significant.
Mitigation Measures: None required.
Monitoring: None required.
Sources: Sanitary Sewer Management Plan, CVWD, December 1, 2019; 2020 Coachella Valley Regional Urban Water
Management Plan, Water Systems Consulting, Inc., June 30, 2021; Solid Waste Information System, www2.calrecyle.ca.gov,
CalRecycle, accessed March 2024; Project materials.
145
-78-
XX. WILDFIRE – If located in or
near state responsibility areas or lands
classified as very high fire hazard
severity zones, would the project:
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Substantially impair an adopted
emergency response plan or emergency
evacuation plan?
✓
b) Due to slope, prevailing winds, and other
factors, exacerbate wildfire risks, and
thereby expose project occupants to,
pollutant concentrations from a wildfire or
the uncontrolled spread of a wildfire?
✓
c) Require the installation or maintenance of
associated infrastructure (such as roads, fuel
breaks, emergency water sources, power
lines or other utilities) that may exacerbate
fire risk or that may result in temporary or
ongoing impacts to the environment?
✓
d) Expose people or structures to significant
risks, including downslope or downstream
flooding or landslides, as a result of runoff,
post-fire slope instability, or drainage
changes?
✓
Setting
Wildfires can occur in undeveloped areas and spread to urban areas. The California Department of
Forestry and Fire Protection (CalFire) has mapped areas of significant fire hazards in the state through its
Fire and Resources Assessment Program (FRAP). These maps identify fire hazard severity zones (FHSZ)
based on a hazard scoring system using subjective criteria for fuels, fire history, terrain influences, housing
density, and occurrence of severe weather where urban conflagration could occur.
The City’s General Plan Fire Hazard Severity Zones map (Figure 8.5) identifies the site as being in a
moderate to high fire hazard zone due to its proximity to the the Santa Rosa Mountains. The Project site
is not located in or near a state responsibility area (SRA) or very high fire hazard severity zone (VHFHSZ).
According to current (2024) mapping, the nearest VHFHSZ and SRA are 1.5 miles to the south in the
Santa Rosa Mountains.
In response to the potential for wildfire and related impacts, the Riverside County MJHMP declares
wildfire as a level 4 natural hazard, meaning it can occur at least once a year.16 To reduce potential impacts,
the County’s MJHMP grants the Riverside County Fire Department and Cal Fire the authority to oversee
and manage the implementation of the following county-wide mitigation actions:
• Removal of vegetation and brush in heavily populated area prone to fire;
• Enact fuel reduction projects throughout the county to reduce fire potential;
16 County of Riverside Emergency Management Department, Multi-Jurisdictional Local Hazard Mitigation Plan, 2018.
146
-79-
• Create wildfire protection zones that reduce the risks to citizens and firefighters from fire dangers;
• Strengthen defensible space inspections in fire prone areas;
• Develop and enforce construction and design standards that ensure the development incorporates
fire prevention features;
• Conduct and implement long range fire safety planning through code adoption/policies
In addition, the City’s Local Hazard Mitigation Plan (LHMP) assess potential natural hazards, including
wildfire, and sets city-specific goals, objectives, and mitigation strategy. Some mitigation strategies to
combat wildfire are:
• Establish and maintain a database containing maps and other information that identifies and
describes the community hazards;
• Maintain and regularly update the City’s LHMP as an integrated component of the General Plan,
in coordination with Riverside County and other participating jurisdictions to maintain eligibility
for maximum grant funding;
• Maintain optimal fire readiness and response service in coordination with Riverside County and
other agencies.
Furthermore, the local Building and Ordinance Code establishes standards and regulations which all new
developments must comply with in order to receive land use permit approval. In all, the County of
Riverside and City of Palm Desert regulatory framework addresses and aims to reduce the potential impact
of wildfire to the development environment.
Discussion of Impacts
a) No Impact. The Living Desert has a primary entrance used on a daily basis by the general public
and a secondary exit point reserved for special events. Both points are located on Portola Avenue.
Under the City’s Emergency Preparation Plan, Portola Avenue is designated an evacuation route
that connects to Highway-111.17
During the construction phase, no obstructions or major delays are planned to occur on Portola
Avenue which would prevent the access or use of the roadway as an evacuation route. All
construction activities will be limited within the Living Desert’s boundary. While in operation the
Project will not prevent the access to any evacuation route or limit the effectiveness of the Living
Desert’s or the City’s emergency evacuation plan. No impacts are expected.
b) Less Than Significant Impact. The City’s General Plan Fire Hazard Severity Zones Map
designates portions of the Palm Desert’s southern region as a VHFHSZ based on fuel load, slope,
fire weather, and other relevant factors.18 The Living Desert, located in City’s southern portion is
in proximity to a high hazard zone and is itself located in a Moderate to High Fire Hazard Zone.
The Project proposes the development of an event center, lion habitat, entry pavilion, and
associated structures located at the center of the park, immediately northeast of the main entrance.
The construction and design of the Project will remain in compliance with the local and State
Building Codes regarding fire safety which includes fire prevention features. The implementation
17 City of Palm Desert, General Plan, Safety Element, 2016.
18 City of Palm Desert, General Plan, Safety Element, 2016.
147
-80-
and adoption of these standards will minimize occupants’ exposure to pollutant concentration from
a wildfire or the uncontrolled spread of a wildfire. In addition, the Project will be inspected prior
to operation in order to ensure all fire safety standards are met at a satisfactory level. For these
reasons, the Project’s impacts are expected to be less than significant.
c) No Impact. The Project is planned to occur on a developed parcel within the existing footprint of
the Living Desert. As a fully operational zoo, the Living Desert has the adequate infrastructure
required to service the Project. The construction of infrastructure including roads, fuel breaks,
emergency water source, power lines, or other utility is not required, except for onsite connections.
Therefore, no environmental impacts related with the development of these utilities will occur. No
impacts are expected.
d) Less Than Significant Impact. According to the City’s General Plan FEMA Flood Zone, 100-
year and 500-year flood zones are located to the southeastern corner of the City’s boundary. The
Living Desert is not on or adjacent to a 100-year or a 500-year flood zone. The risk of a flood
hazard impacts on the Living Desert and the Project are low to very low because based on its
geographical location, flooding is not a hazard of concern. Impacts are anticipated to be less than
significant.
Mitigation Measures: None required.
Monitoring: None required.
Sources: City of Palm Desert General Plan, 2016; Project materials; Google Earth; Fire Hazard Severity Map, CalFire,
https://egis.fire.ca.gov/FHSZ/, accessed March 2024.
148
-81-
XXI. MANDATORY FINDINGS OF
SIGNIFICANCE
Potentially
Significant
Impact
Less Than
Significant
with
Mitigation
Less Than
Significant
Impact
No
Impact
a) Does the project have the potential to
substantially degrade the quality of the
environment, substantially reduce the
habitat of a fish or wildlife species, cause a
fish or wildlife population to drop below
self-sustaining levels, threaten to eliminate
a plant or animal community, substantially
reduce the number or restrict the range of a
rare or endangered plant or animal or
eliminate important examples of the major
periods of California history or prehistory?
✓
b) Does the project have impacts that are
individually limited, but cumulatively
considerable? (“Cumulatively considerable”
means that the incremental effects of a
project are considerable when viewed in
connection with the effects of past projects,
the effects of other current projects, and the
effects of probable future projects)?
✓
c) Does the project have environmental
effects, which will cause substantial adverse
effects on human beings, either directly or
indirectly?
✓
a) Less than Significant with Mitigation.
Biological Resources: The Project is not expected to substantially degrade environmental quality
or reduce the habitat, population, or range of a fish or wildlife species. However, bird species
covered under the Migratory Bird Treaty Act (MBTA) could potentially occur onsite.
Implementation of mitigation measure BIO.1 will mitigate impacts to those species. With
mitigation, impacts will be less than significant.
Cultural Resources: No cultural resources are known to exist within or adjacent to the fully
developed Project site, and no impact is expected. The ACBCI, however, requested the presence
of a Tribal Monitor during earth moving activities, to assure that any buried resource would be
addressed. Mitigation Measure TCR-1 will reduce impacts to Tribal Cultural Resources to less
than significant levels.
149
-82-
b) Less than Significant Impact. Project impacts will not be cumulatively considerable because the
Project is part of a planned expansion within the Living Desert and is consistent with the Zoo’s
existing uses. The Project would not induce population growth, as employees are expected to be
existing employees of the Living Desert or from the local population. Being that it is a facilities
expansion project and not a new use, the Project’s incremental effects are not considerable when
viewed in connection with other projects. Impacts will be less than significant.
c) Less than Significant with Mitigation. The Project could cause environmental effects that could
cause adverse effects on humans, specifically as it relates to geotechnical impacts. However, the
mitigation measures provided in this Initial Study and supporting documentation cited herein will
reduce potential impacts to less than significant levels.
150
A
Appendix A
CalEEMOD Air Quality and GHG Modeling
(Available on City website)
151
B
Appendix B
Geotechnical Investigation
(Available on City website)
152
C
Appendix C
Preliminary Hydrology Report
(Available on City website)
153
D
Appendix D
Trip and Parking Generation Analysis
(Available on City website)
154
EXHIBIT B
CONDITIONS OF APPROVAL
CASE NOS. CUP/PP/EA23-0010
PLANNING DIVISION:
1. The development of the property shall conform substantially with exhibits on file with the
Development Services Department, except as modified by the following conditions. Any
variation from the approved plans must be reviewed and approved by the Planning
Division prior to the building permit issuance and may require review and approval by the
Architectural Review Commission, Planning Commission, and/or City Council.
2. The Applicant agrees that in the event of any administrative, legal, or equitable action
instituted by a third party challenging the validity of any of the procedures leading to the
adoption of these project approvals for the Project, or the project approvals themselves,
the Developer and City each shall have the right, in their sole discretion, to elect whether
or not to defend such action. Developer, at its sole expense, shall defend, indemnify, and
hold harmless the City (including its agents, officers, and employees) from any such
action, claim, or proceeding with counsel chosen by the City, subject to the Developer’s
approval of counsel, which shall not be unreasonably denied, and at the Developer’s sole
expense. If the City is aware of such an action or proceeding, it shall promptly notify the
Developer and cooperate in the defense. The Developer, upon such notification, shall
deposit with City sufficient funds in the judgment of the City Finance Director to cover the
expense of defending such action without any offset or claim against said deposit to
assure that the City expends no City funds. If both Parties elect to defend, the Parties
hereby agree to affirmatively cooperate in defending said action and to execute a joint
defense and confidentiality agreement in order to share and protect the information under
the joint defense privilege recognized under applicable law. As part of the cooperation in
defending an action, City and Developer shall coordinate their defense in order to make
the most efficient use of legal counsel and to share and protect information. Developer
and City shall each have sole discretion to terminate its defense at any time. The City
shall not settle any third-party litigation of project approvals without the Developer’s
consent, which consent shall not be unreasonably withheld, conditioned, or delayed
unless the Developer materially breaches this indemnification requirement.
3. The Applicant shall adhere to all of the mitigation measures identified in the Mitigated
Negative Declaration prepared as part of this project and incorporated as Exhibit B of
Resolution 2877.
4. The Applicant shall adhere to the operations identified in the Mitigated Negative
Declaration prepared as part of this project and incorporated as Exhibit B of Resolution
2877.
5. The development of the property described herein shall be subject to the restrictions and
limitations set forth herein, which are in addition to the approved development standards
listed in the PDMC and state and federal statutes now in force, or which hereafter may be
in force.
155
PLANNING COMMISSION RESOLUTION NO. 2877
2
6. The Precise Plan (PP) shall expire if construction of the said Project shall not commence
within 24 months from the date of final approval unless an extension of time is granted
by the Palm Desert Planning Commission; otherwise, said approval shall become null,
void, and of no effect whatsoever.
7. The Conditional Use Permit (CUP) shall expire if construction of the said Project shall
not commence within 24 months from the date of final approval unless an extension of
time is granted by the Palm Desert Planning Commission; otherwise, said approval shall
become null, void, and of no effect whatsoever.
8. The approved CUP and PP shall only be modified with written City approval per PDMC
Chapter 25.72.030. Any proposed changes to this CUP and PP will require an
amendment to the application, which may result in a new public hearing.
9. All construction documentation shall be coordinated for consistency, including, but not
limited to, architectural, structural, mechanical, electrical, plumbing, landscape and
irrigation, grading, and street improvement plans. All such plans shall be consistent with
the approved entitlement plans on file with the Development Services Department.
10. Prior to the issuance of a building permit for the construction of any use or structure
contemplated by this approval, the Applicant shall first obtain permits and or clearance
from the following agencies:
Coachella Valley Water District (CVWD)
City of Palm Desert Public Works Department
Riverside County Fire Department
City of Palm Desert Land Development Division
City of Palm Desert Planning Division
City of Palm Desert Building and Safety Division
Evidence of said permit or clearance from the above agencies shall be presented to the
Building & Safety Division at the tim e of issuance of a building permit for the use
contemplated herewith.
11. This Project is subject to the Art in Public Places requirements in Chapter 4.10 of the
PDMC.
12. Final lighting plans shall be submitted per PDMC Section 24.16 for any landscape,
architectural, street, or other lighting types within the Project area.
All exterior lighting sources shall be fully shielded and directed downwards and is subject
to approval by the Development Services Department. Luminaries with total lamp lumens
above 16,000 lumens shall not be used. Prior to the building permit issuance, the
Applicant shall submit plans for outdoor lighting as required by PDMC Section 24.16.030
and include glare ratings and color temperature for all exterior light fixtures.
13. Prior to the building permit issuance, the Applicant shall submit a landscape construction
application for approval by the Development Services Department and Coachella Valley
156
PLANNING COMMISSION RESOLUTION NO. 2877
3
Water District. Final landscape and irrigation documents shall be prepared by a
landscape architect registered with the State of California and shall be submitted to the
Development Services Department and the CVWD for review and approval. All sheets
shall be signed by the landscape architect and shall include the license number and the
expiration date. The landscape plan shall conform to the preliminary landscape plans
prepared as part of this application and shall include dense plantings of live landscape
material. All plants shall be a minimum of five (5) gallons in size, and all trees shall be a
minimum 24-inch box in size.
A. The Applicant shall submit final landscape construction plans to the Palm Desert
Development Services Department for review and acceptance prior to submittal to
CVWD.
14. All Project irrigation systems shall function properly, and landscaping shall be maintained
in a healthy and thriving condition. The maintenance of landscaping and the irrigation
system shall be permanently provided for all areas of the Project site, as well as walkways
and the portion of public right-of -way abutting the Project site (parkways). Furthermore,
the plans shall identify responsibility for the continued maintenance.
15. Prior to the issuance of the Certificate of Occupancy, the Project landscape architect shall
submit written certification to the Planning Division that the landscaping and irrigation
have been installed per the approved landscape plan, by completing a Certificate of
Completion.
16. All exterior ground-mounted and rooftop equipment and all appurtenances thereto shall
be completely screened from public view by walls or roof screens that are architecturally
treated to be consistent with the building. The final construction plans shall include
appropriate drawings demonstrating how such equipment is to be screened from view.
17. All roof drainage systems and devices shall be designed such that they are fully screened
from view from all public streets. Drainage devices, including but not limited to down -
spouts, shall not be located on any street-facing building elevation or area that is clearly
visible from the public right-of-way. Drainage devices shall be fully integrated into the
building structure and located within the exterior walls of the structure.
18. All ground-mounted utility structures including, but not limited to, transformers, HVAC
equipment, and backflow prevention valves shall be located out of view from any public
street or adequately screened using landscaping and/or permanent screening devices.
19. Exterior building elevations showing building wall materials, roof types, exterior colors,
and appropriate vertical dimensions shall be included in the development construction
drawings.
20. The Applicant or any successor in interest shall comply with all applicable local, state,
and federal laws and regulations.
157
PLANNING COMMISSION RESOLUTION NO. 2877
4
21. A copy of the herein-listed Conditions of Approval shall be included in the construction
documentation package for the Project, which shall be continuously maintained on-site
during Project construction.
22. Exterior signage shall comply with Chapter 25.56 of the PDMC.
23. Prior to a permit issuance, the Applicant shall submit plans for the final design of all site
fences and walls subject to review and approval by the Palm Desert Development
Services Department.
LAND DEVELOPMENT DIVISION:
24. The following plans, studies, and exhibits are hereby referenced: Phase 3.0 Preliminary
Grading Exhibit, prepared by MSA Consulting, Inc., dated May 8, 2024.
25. It is assumed that easements shown on the preliminary grading exhibit are shown
correctly and include all the easements that encumber the subject property. A current
preliminary title report for the site will be required to be submitted during technical plan
review. The applicant shall secure approval from all, if any, easement holders for all
grading and improvements, which are proposed over the respective easement or provide
evidence that the easement has been relocated, quitclaimed, vacated, abandoned,
easement holder cannot be found, or is otherwise of no effect. Should such approvals or
alternate actions regarding the easements not be provided and approved by the City, the
applicant may be required to amend or revise the proposed site configuration as may be
necessary.
26. All utility extensions within the site shall be placed underground unless otherwise specified
or allowed by the respective utility purveyor.
27. Prior to any work within the public right-of-way, the applicant shall obtain an encroachment
permit from the City’s Public Works Department.
28. Prior to grading permit, the applicant shall provide a copy of approved water and sewer
plans, by Coachella Valley Water District (CVWD) and submit financial security and
assurance for the improvements in a manner and amount approved by the City Engineer.
29. Prior to grading permit, the applicant shall submit final Grading Plans for review and
approval by the City Engineer. Final grading plans shall conform to the approved
Conceptual Grading Plan, the California Building Code, PDMC Title 27 Grading, and all
other relevant laws, rules, and regulations governing grading in the City of Palm Desert.
A. The grading plan and hydrology report shall provide for acceptance and proper
conveyance of all off-site or on-site drainage flowing onto or through the site.
B. Pad elevations, as shown on the conceptual exhibit, are subject to review and
modification per Chapter 27 of the PDMC.
C. Verification that coordination with the City of Indian Wells was accepted for all
facilities and/or improvements within their City Boundaries.
158
PLANNING COMMISSION RESOLUTION NO. 2877
5
30. Prior to issuance of grading permit, the applicant shall prepare a Storm Water Pollution
Prevention Plan (SWPPP) in conformance with the State’s current Construction Activities
Storm Water General Permit.
31. Prior to grading permit, the applicant shall pay all appropriate signalization and impact
fees in accordance with the City’s Resolution No. 79-17 and 79-55.
32. Prior to approval of the grading plans, the applicant shall provide the City Engineer with
evidence that a Notice of Intent (NOI) has been filed with the State Water Resources
Control Board. Such evidence shall consist of a copy of the NOI stamped by the State
Water Resources Control Board or the Regional Water Quality Control Board, or a letter
from either agency stating that the NOI has been filed. The Waste Discharger’s
Identification number (WDID#) shall be noted on the grading plans.
33. Prior to the issuance of a grading permit, the applicant shall submit a PM10 application
for review and approval. The applicant shall comply with all provisions of PDMC Section
24.12 regarding Fugitive Dust Control.
34. Prior to issuance of grading permit, the applicant shall obtain the relevant permit(s) for the
hauling of imported or exported earthwork materials.
35. Prior to grading permit, a site specific geotechnical report shall be submitted for review
and approval and the Geotechnical Engineer shall approve the grading plans are in
conformance to their recommendations and conclusions.
36. It is assumed that the grading and the provisions for water quality management shown on
the conceptual grading exhibit and Preliminary Water Quality Management Plan can
comply with all requirements for a Final Water Quality Management Plan (F-WQMP),
without substantial change from that shown. Prior to approval of the grading plan the
applicant shall submit a Final WQMP in conformance with the requirements of the
Riverside County Flood Control and Water Conservation District (RCFC&WCD)
Whitewater River Watershed area for approval of the City Engineer.
A. Infiltration rates, for purposes of sizing the proposed retention, shall be no more
than 1-in/hr only if percolation tests are conducted in the field by a licensed
geotechnical engineer, validating at least twice this amount; or as otherwise
approved by the City Engineer.
B. In compliance with the City’s Municipal Code, project BMPs shall
accommodate the 100-year 24-hour storm.
37. Prior to grading permit, and in compliance with the City’s Municipal Code Chapter 27.24,
the applicant shall enter into an agreement and post financial security to guarantee the
safe completion of grading operations and implementation, including as necessary,
maintenance of erosion control measures.
38. Prior to building permit, the project’s Engineer of Record and Geotechnical Engineer shall
certify the completion of grading in conformance with the approved grading plans and
recommendations of the approved geotechnical report.
159
PLANNING COMMISSION RESOLUTION NO. 2877
6
39. Prior to building permit, applicant shall provide grading pad or form certification by a
licensed Land Surveyor or Civil Engineer of Record in a form approved by the City
Engineer.
40. Prior to building permit sign-off, the applicant shall provide to the City written proof of
Coachella Valley Water District acceptance of all relevant water and sewer improvements.
BUILDING AND SAFETY DIVISION:
41. This Project shall comply with the latest adopted edition of the following codes:
A. California Building Code and its appendices and standards.
B. California Commercial Code and its appendices and standards.
C. California Plumbing Code and its appendices and standards.
D. California Mechanical Code and its appendices and standards.
E. California Electrical Code.
F. California Energy Code.
G. California Green Building Standards Code.
H. Title 24, California Code of Regulations.
I. California Fire Code and its appendices and standards.
42. The Applicant shall coordinate directly with:
Riverside County Fire Marshal’s Office
CAL FIRE/Riverside County Fire Department
Main: (760) 863-8886
77933 Las Montañas Road, Suite 201
Palm Desert, CA 92211
43. All trash enclosures are required to be accessible. Provide an accessible path of travel
to the trash enclosure. Trash enclosures shall comply with the minimum requirements
established by Section 8.12 of the PDMC.
44. All contractors and subcontractors shall have a current City of Palm Desert Business
License before permit issuance per PDMC, Title 5.
45. All contractors and/or owner-builders must submit a valid Certificate of Workers’
Compensation Insurance coverage before the issuance of a building permit per California
Labor Code, Section 3700.
46. California Accessibility Requirements. The accessibility provisions of CBC Chapter 11B
applies to this project. For development review consideration:
- Ensure accessible parking is dispersed to accommodate an even distribution.
- Identify EV accessible parking.
- Review paths of travel within community buildings and amenities to all trash enclosures
and recycling areas. - Include to dog park.
160
PLANNING COMMISSION RESOLUTION NO. 2877
7
47. 2022 California Energy Requirements. The non-residential and multi-family energy
provisions will apply to this project. For development review purposes, properly identify:
- All solar access roof areas, as needed. (Note provided but not demonstrated.)
- Any detached or remote battery storage areas, if designed, are identified within the Site
Plan.
48. 2022 California Green Building Requirements. The non-residential and multi-family CGBC
provisions will apply for this project. For development review considerations:
- Identify the proposed EV spaces of residential and non-residential areas.
- Identify areas designated for recycling (CGBC 4.410.2 Recycling by Occupants).
49. Address numerals shall comply with Palm Desert Ordinance No. 1351 (PDMC Section
15.28). Compliance with Ordinance 1351 regarding street address location, dimension,
stroke of line, distance from the street, height from grade, height from the street, etc.,
shall be shown on all architectural building elevations in detail. Any possible obstructions,
shadows, lighting, landscaping, backgrounds, or other reasons that may render the
building address unreadable shall be addressed during the plan review process. The
Applicant may request a copy of Ordinance 1351 or PDMC Section 15.28 from the
Building and Safety Division counter staff.
END OF CONDITIONS OF APPROVAL
161
162
PREST | VUKSIC | GREENWOOD
A R C H I T E C T S I N T E R I O R S
THE LIVING DESERT ZOO & GARDENS
ENTITLEMENT SET
JUNE 26, 2023
CONNIE AND BOB LURIE EVENT CENTER
AND
LION HABITAT
PHASE 3.0
PALM DESERT, CA
163
PORTOLA AVESheet:
Scale:
INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
PREST VUKSIC GREENWOOD
A R C H I T E C T S • I N T E R I O R S
12" = 1'-0"
A001
PROJECT
INFORMATION
-THE LIVING DESERT ZOO & GARDENS
CONNIE AND BOB LURIE EVENT CENTER 222028A-3/B
-
V-A
YES
31'-0"
2
OCCUPANCY
OCCUPANCY LOAD
TYPE OF CONSTRUCTION
SPRINKLERED
NO. OF STORIES
GREATEST HEIGHT
NO. OF EXITS REQ'D
PROJECT INFORMATION
OWNER
THE LIVING DESERT ZOO & GARDENS
47-900 PORTOLA AVE
PALM DESERT CA 92260
APPLICANT
PREST VUKSIC GREENWOOD ARCHITECTS
44-530 SAN PABLO AVE., STE 200
PALM DESERT, CA 92260
LEGAL DESCRIPTION
APN 630250045, 625300052
PROJECT DESCRIPTION / LOCATION
THIS PROJECT IS AN AMENDMENT TO THE PREVIOUS
ENTITLEMENT FOR THE LIVING DESERT (PP/CUP 15-370)
THE PREVIOUS APPROVALS HAD INCLUDED THE LION
HABITAT & BANQUET FACILITY DESCRIBED AS PHASE 3.0.
THIS AMENDMENT INCLUDES ADDED SCOPE AND SQUARE
FOOTAGE TO THE EVENT CENTER, AND LION HABITAT. IT
INTRODUCES A NEW ENTRY BUILDING ON THE NORTH SIDE
OF THE CHASE BUILDING.
THE PROJECT CONSISTS OF A NEW 37,650 SF EVENT
CENTER AND A SECOND-STORY ADMINISTRATION OFFICE
WITH A DIRECT CONNECTION TO THE EXISTING STEVE
CHASE ADMINISTRATIVE CENTER BUILDING. THE EVENT
CENTER WILL INCORPORATE A FULL COMMERCIAL
KITCHEN TO SERVE THE EVENT CENTER IN ADDITION TO
SUPPORTING THE ADDITIONAL RETAIL FOOD FACILITIES
WITHIN THE ZOO.
A NEW 1,250 SF ENTRANCE/TICKETING STRUCTURE WILL
BE LOCATED AT THE NORTH SIDE OF THE CHASE BUILDING.
THIS WILL SERVE AS AN ENTRANCE POINT FOR THE
CONNIE AND BOB LURIE EVENT CENTER AND FOR DAILY
SCHOOL FIELD TRIPS INTO THE ZOO.
ADDITION OF THREE NEW LION HABITATS CONSISTING OF
APPROXIMATELY 36,000 SF AND ASSOCIATED STRUCTURES
CONSISTING OF LION CARE FACILITIES, SHADE/VIEWING
STRUCTURES, AND INTERPRETIVE PATHWAYS
THROUGHOUT THE EXHIBIT.
ZONING
CITY OF PALM DESERT P.D-DRAINAGE FLOOD
PLAINS & WATERCOURSE
AREA & BUILDING DATA
SITE ACREAGE:
GROSS ACREAGE:
CONNIE AND BOB LURIE EVENT CENTER
PARKING DATA
REQUIRED PARKING
MIXED USE - TO BE DETERMINED
PARKING PROVIDED
BUILDING DATA
5 AC.
CONSULTANTS
PREST VUKSIC GREENWOOD ARCHITECTS
44-530 SAN PABLO AVE., STE 200
PALM DESERT, CA 92260
760.779.5393
JOHN GREENWOOD, LEED AP
ARCHITECT
GLMV ARCHITECTURE
1525 E. DOUGLAS
WICHITA, KS 67211
316.265.9367
COOPER DAHMS , AIA
ARCHITECT - EXHIBIT
GLMV LANDSCAPE ARCHITECTURE
CHAD WEINAND, PLA, ASLA, LEED AP
LANDSCAPE ARCHITECT
MSA CONSULTING, INC.
34200 BOB HOPE DRIVE
RANCHO MIRAGE, CA 92270
760.320.9811
RODNEY REED, PE
CIVIL ENGINEER
BUEHLER ENGINEERING, INC.
600 Q STREET
SUITE 200
SACRAMENTO, CA 95811
916.443.0303
RON MIGLIORI, SE
STRUCTURAL ENGINEER
ELECTRICAL ENGINEERS
AG DESIGN INC.
CONSULTING ELECTRICAL ENGINEERS
2100 W. ORANGEWOOD AVE., SUITE 165
ORANGE, CA 92868
714.769.9900
ADAM SLOAN, PE L PRINCIPAL
MECHANICAL ENGINEERS
SHADPOUR CONSULTING ENGINEERS, INC (SC
ENGINEERS)
17075 VIA DEL CAMPO
SAN DIEGO, CA 92127
858.946.0333
JEREMY CLIFTON
VICINITY MAP
EVENT SPACE: 13,130 SF
KITCHEN & B.O.H.: 20,620 SF
ADMINISTRATION 2ND FLOOR: 7,490 SF
TOTAL: 37,650 SF
EXISTING :
854 STANDARD SPACES
20 ADA SPACES
14 BUS SPACES
49 EMPLOYEE SPACES
PER 11B-208.2 CALDAG 2% OF ADA PARKING REQUIRED
681X0.02= 13.62 = 14 SPACES REQUIRED
TOTAL OF ADA SPACES CURRENTLY = 20
PROPOSED:
1 ADA PARKING SPACE TO BE REMOVED
TOTAL ADA PARKING SPACES PROVIDED = 19
NO OTHER CHANGES AT PARKING SPACES
PER CBC CH6. TABLE 601 FIRE RESISTANCE RATING
REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) FOR
TYPE V-A CONSTRUCTION:
PRIMARY STRUCTURAL FRAME
(PER SECTION 202): 1 HOUR
INTERIOR & EXTERIOR BEARING WALLS: 1 HOUR
NONBEARING WALLS AND PARTITIONS
EXTERIOR (PER TABLE 705.5): 1 HOURS
NONBEARING WALLS & PARTITIONS
INTERIOR: 0 HOURS
FLOOR CONSTRUCTION & ASSOCIATED
SECONDARY MEMBERS: 1 HOUR
ROOF CONSTRUCTION AND ASSOCIATED
SECONDARY MEMBERS: 1 HOUR
ALL PRIMARY STRUCTURE WITHIN WALLS SHALL BE
WRAPPED W/ 1 LAYER 5/8" TYPE X GYP. BOARD.
PER CBC 705.10 DUCTS AND AIR TRANSFER OPENINGS:
PENETRATIONS BY AIR DUCTS AND AIR TRANSFER
OPENINGS IN FIRE-RESISTANCE-RATED EXTERIOR WALLS
REQUIRED TO HAVE PROTECTED OPENINGS SHALL
COMPLY WITH SECTION 717.
EXCEPTION: FOUNDATION VENTS INSTALLED IN
ACCORDANCE WITH THIS CODE ARE PERMITTED.
BUILDING CODE NOTES:
BUILDING AREA:
A-3/B
-
V-B
-
1
22'-8"
-
OCCUPANCY
OCCUPANCY LOAD
TYPE OF CONSTRUCTION
SPRINKLERED
NO. OF STORIES
GREATEST HEIGHT
NO. OF EXITS REQ'D
BUILDING AREA:
BUILDING DATA
TOTAL: 1,250 SF
CONNIE AND BOB LURIE EVENT
CENTER ENTRY PAVILION
B
-
V-B
YES
1
21'-2"
-
OCCUPANCY
OCCUPANCY LOAD
TYPE OF CONSTRUCTION
SPRINKLERED
NO. OF STORIES
GREATEST HEIGHT
NO. OF EXITS REQ'D
BUILDING AREA:
BUILDING DATA
TOTAL: 3,810 SF
LION HABITAT
LION CARE CENTER
TOTAL AREA: 10,523 SF
LOWLANDS LION HABITAT
TOTAL AREA: 10,988 SF
GRASSLANDS LION HABITAT
TOTAL AREA: 10,207 SF
LOWLANDS LION HABITAT
CONNIE AND BOB LURIE EVENT CENTER
A200 PLAN EXHIBIT - 1ST FLOOR
A201 PLAN EXHIBIT - 2ND FLOOR
A202 OVERALL FIRST FLOOR PLAN
A203 OVERALL SECOND FLOOR PLAN
A211 FIRST FLOOR PLAN EVENT CENTER
A212 FIRST FLOOR PLAN KITCHEN
A213 FIRST FLOOR PLAN LEGACY GARDEN
A221 SECOND FLOOR PLAN
A301 ELEVATIONS
A302 ELEVATIONS
A303 COLORED ELEVATIONS
A304 COLORED ELEVATIONS
A401 EVENT CENTER BUILDING SECTION
A402 WALL SECTION DETAILS
A500 ROOF PLAN
A601 REFLECTED CEILING PLAN FIRST FLOOR
A602 REFLECTED CEILING PLAN SECOND FLOOR
A701 MATERIAL BOARD
A800 EVENT CENTER 3D VIEWS
A801 EVENT CENTER 3D VIEWS
A802 CONNIE AND BOB LURIE EVENT CENTER PATIO
CONNIE AND BOB LURIE ENTRY PAVILION
A501 ROOF PLAN
EVENT CENTER ENTRY PAVILION
A201 FLOOR PLAN
A301 ELEVATIONS
A310 COLORED ELEVATIONS
A401 SECTIONS
A601 3D VIEWS
A602 3D VIEWS
A701 MATERIAL BOARD
LION HABITAT
0_EA1.0 LION HABITAT
0_EA2.0 LION HABITAT KEYMAP
1_EA1.01 LION CARE CENTER FLOOR PLAN
1_EA1.31 LION CARE CENTER ROOF PLAN
1_EA2.01 LION CARE CENTER ELEVATIONS
2_EA1.01 SURROUND PLANS
2_EA2.01 SURROUND ELEVATIONS
2_EA2.02 SURROUND ELEVATIONS
3_EA0.11 GRASSLANDS POCKET VIEW
3_EA1.01 GRASSLAND VIEW STRUCTURE FLOOR PLAN
3_EA1.02 GRASSLAND VIEW SHELTER ROOF PLAN
3_EA2.01 GRASSLANDS VIEW STRUCTURE ELEVATIONS
3_EA2.02 GRASSLANDS VIEW STRUCTURE ELEVATIONS
4.1_EA1.01 PALM PATIO VIEWING PLANS
4.1_EA2.01 PALM PATIO VIEWING ELEVATIONS
4.1_EA2.02 PALM PATIO VIEWING ELEVATIONS
4.2_EA1.0 DELTA VIEWING PLANS
4.2_EA2.01 DELTA VIEWING ELEVATIONS
4.2_EA2.02 DELTA VIEWING ELEVATIONS
5_EA1.01 LOWLANDS VIEWING SHELTER PLANS
5_EA2.01 LOWLANDS VIEWING SHELTER ELEVATIONS
5_EA2.02 LOWLANDS VIEWING SHELTER ELEVATIONS
6_EA1.01 OVERHEAD TRANSFER PLANS
6_EA2.01 OVERHEAD TRANSFER ELEVATIONS
6_EA2.02 OVERHEAD TRANSFER ELEVATIONS
10_EA1.0 3D VIEWS
LANDSCAPE
L101 PRELIMINARY LANDSCAPE PLANS
L102 PRELIMINARY LANDSCAPE PLANS COLORED
L103 PRELIMINARY LANDSCAPE PLANS PLANT IMAGES
CIVIL
C1.0 PH 2.75 AND 3.0 SITE CVWD UTILITIES SERVICE
C2.0 PHASE 3.0 PRELIMINARY WATER, SEWER AND FIRE
C2.1 PHASE 3.0 PRELIMINARY FIRE ACCESS AND HOSE REACH
EXHIBIT
C3.0 PHASE 3.0 PRELIMINARY GRADING EXHIBIT
C3.1 PHASE 3.0 PRELIMINARY GRADING EXHIBIT
C4.0 PHASE 3.0 TRUCK ACCESS EXHIBIT
SHEET NO. SHEET NAME
GENERAL
A000 COVER SHEET
A001 PROJECT INFORMATION
SITE PLAN
A100 OVERALL SITE PLAN PH 3.0
A100.1 PH 3.0 SITE PLAN
A101 EVENT SPACE SITE PLAN
A102 ENTRY PAVILION SITE PLAN
A120 PHASING MAP
A121 PEDESTRAIN ROUTE
THE BOB AND CONNIE LURIE CENTER WILL NOT SCHEDULE MAJOR
PROGRAMS DURING PEAK ATTENDANCE AT THE LIVING DESERT
GARDENS AND ZOO
THE BOB AND CONNIE LURIE CENTER WILL NOT SCHEDULE MAJOR
PROGRAMS DURING THE SAME HOURS FOR SPECIAL PROGRAMS
SUCH WILD LIGHTS AND GLOW IN THE PARK
THE BOB AND LAURIE CENTER MAY HOLD MINOR PROGRAMS (LESS
THAN 100 ATTENDEES) DURING PEAK ATTENDANCE AT THE LIVING
DESERT GARDENS AND ZOO
THE BOB AND LAURIE CENTER MAY HOLD MINOR PROGRAMS (LESS
THAN 100 ATTENDEES) DURING SPECIAL PROGRAMS SUCH AS WILD
LIGHTS AND GLOW IN THE PARK
THE BOB AND CONNIE LAURI CENTER WILL BE ALLOWED TO HAVE
MAJOR PROGRAMS AND SPECIAL PROGRAMS DURING PEAK
ATTENDANCE ONLY IF THE ATTENDEES ARE BUSSED IN FROM
REMOTE LOCATIONS SUCH AS HOTELS AND REMOTE PARKING LOTS.
PARKING CONSIDERATION
164
AVE.CITY OF INDIAN WELLSCITY OF PALM DESERT630-250-045 625-300-052PORTOLA AVE.SPSP
HOOVER DISCOVERY CENTER
BO
M
MMMM
SPLASH ZONE
BIGHORN CAFE
EVENT
CENTER
MM
MMMM M A/VMM
M
M
M M
M
0'80'
SCALE 1"=40'
40'120'160'
%%uLEGEND
%%UBENCHMARK B.M. #125
%%ULOCATION
%%UBASIS OF BEARINGS
%%UELEVATION 361.564'%%UDATUM NAVD88
MARCO T. CELEDON, R.C.E. NO. C75478
PREPARED UNDER THE DIRECT SUPERVISION OF:
\pxqj;THE BASIS OF BEARINGS FOR THIS SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, ZONE 6, NAD 83 (EPOCH 2004) IDENTIFIED LOCALLY BETWEEN CITY OF PALM DESERT BENCHMARKS 124 AND 125.\~ TAKEN AS N 87°11'29" W.
WEST SIDE OF PORTOLA AVE. BETWEEN HAYSTACK RD. AND SILVER SPUR TR. AT THE NORTHERLY END OF CB, 1.2' WEST OF CF, 3.2' SOUTH OF PCR, FLUSH.
UNDERGROUND SERVICE ALERT
AT LEAST TWO DAYS BEFORE YOU DIG
1-800-227-2600
DIAL TOLL FREE
Dig Safely
DIG ALERT
T.M.
OF SOUTHERN CALIFORNIA
LAC
LAC
MTC
CHECKED BY
DRAWN BY
DESIGNED BY
DATE
N
I
L
E
N
E
E
R
NA
E IF
C75478
TERE
R
E
I
R
I A
N
I F R
V II
A LF
T
A TE
L
Copyright 2023
All Rights Reserved
MSA Consulting, Inc.c
MARK BY DATE
ENGINEER CITY
DATE
APPR.REVISIONS MSA CONSULTING,INC.
C i v i l E n g i n e e r i n g L a n d S u r v ey i n g L a n d s c a p e A r c h i t e c t u r ePlanningEnvironmentalServicesDryUtilityCoordinationGIS
34200 Bob Hope Drive Rancho Mirage, CA 92270 | 760.320.9811 | MSAConsultinginc.com
05 . 31 . 23
G
JREEN
WOODOHNT.
C-38012
Scale:
Date
Project Number
FOR
THESE DRAWINGS ARE AN INSTRUMENT OF SERVICE AND REMAIN THE
PROPERTY OF PREST VUKSIC GREENWOOD ARCHITECTS. THEY ARE
NOT TO BE REPRODUCED OR ALTERED IN ANY WAY, NOR DISCLOSED
OR ASSIGNED TO ANY THIRD PARTY WITHOUT THE EXPRESS WRITTEN
PERMISSION OF PREST VUKSIC GREENWOOD ARCHITECTS.
INSTRUMENTS OF SERVICE
DAVID G. PREST, AIA C-8690
JOHN J. VUKSIC, AIA C-19210
JOHN T. GREENWOOD, C-38012
760 . 779 . 5393 T
info@pvgarchitects.com
www.pvgarchitects.com
44530 SAN PABLO AVE, STE 200
PALM DESERT, CA 92260
PREST VUKSIC GREENWOODII
A R C H I T E C T S . I N T E R I O R S
STAMP
C1.0
PH 2.75 AND 3.0 SITE CVWD
BIGHORN CAFE
DESIGN DEVELOPMENT
222002
47900 PORTOLA AVE.
PALM DESERT, CA 92260
01/13/2023
RENEWAL
DATEICESED ARCH
IT
ECTSTAT
E
OF C A L IF O RNIAN
LLNo.Description Date
EXISTING CVWD WATER MAIN
MSA CONSULTING,INC.
C i v i l E n g i n e e r i n g L a n d S u r v e y i n g L a n d s c a p e A r c h i t e c t u r ePlanningEnvironmentalServicesDryUtilityCoordinationGIS
34200 Bob Hope Drive Rancho Mirage, CA 92270 | 760.320.9811 | MSAConsultinginc.com
R:\2244\ACAD\Improvement Plans reliminary Water and Sewer hase 2.75-3.0\2244 Phase 2.75 and 3.0 site plan.dwg, 12/21/2023 9:23:35 AM, mpompa, MSA Consulting, Inc.PROPOSED IRRIGATION LINE
PROPOSED SEWER LINE
PROPOSED WATER LINE
PROPOSED FIRE LINE
PROPOSED STORM DRAIN
POC
GAS
GAS
METER
FEGWFMIRRPHASE 3.0
UTILITIES
SERVICE
SCG TO
PROVIDE TWO
(2) SEPERATE
GAS METERS
EEEE
EX. ELECTRIC
SERVICE YARD
G G
UTILITIES SERVICE
165
Sheet:Scale:INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260IIWWW.PVGARCHITECTS.COMA R C H I T E C T S• I N T E R I O R S02/01/2024THE LIVING DESERT ZOO & GARDENSPHASE 3 - EVENT CENTER222028AS NOTEDMSA CONSULTING, INC.Civil Engineering Land Surveying Landscape ArchitecturePlanning Environmental Services Dry Utility Coordination GIS34200 Bob Hope Drive Rancho Mirage, CA 92270 | 760.320.9811 | MSAConsultinginc.comC2.0PHASE 3.0 PRELIMINARYWATER, SEWER AND FIREPREST VUKSIC GREENWOOD166
HOOVER DISCOVERY CENTER
AUSTRALIAN AVIARY
TENNITY AMPITEATER
EDUCATION AND DISCOVERY ROOM
\pxqc;HOOFSTOCK
CHASE BUILDINGMEERKAT CAFE
GIFT SHOP
McMANUS
\pxqc;LAND BRIDGE
\pxqc;TICKET BUILDING
\pxqc;RETAIL BUILDING
BIGHORN SHEEP EXHIBIT
\pxqc;MODEL TRAIN EXHIBIT
MOJAVE GARDEN\pxqc;KEEPER CENTER AND ANIMAL CARE FACILITY
BIGHORN CAFE
\pxqc;EXISTING MADEGASCAR PLANTINGS
MH
MH
MH
MH
MHSTOPSTOPSTOP
MH
MH
MH
MH
STOPAHEAD
STOPMH
MH
MH
SPSP
MH
MH
MH
MH
BO
M MMMM
M
M
M
M
M
M
M
M
M
M
M
M
000
000
000
000
000
000
000
000
0 00
000
CITY OF INDIAN WELLSCITY OF PALM DESERT
625-300-052
658-020-001
630-250-045
\A1;32'%%P\A1;16'000 \A1;18'\A1;19'%%PSheet:
Scale:
INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
A R C H I T E C T S • I N T E R I O R S
05/08/2024THE LIVING DESERT ZOO & GARDENS
PHASE 3 - EVENT CENTER 222028AS NOTEDMSA CONSULTING,INC.
C i v i l E n g i n e e r i n g L a n d S u r v e y i n g L a n d s c a p e A r c h i t e c t u r ePlanningEnvironmentalServicesDryUtilityCoordinationGIS
34200 Bob Hope Drive Rancho Mirage, CA 92270 | 760.320.9811 | MSAConsultinginc.com C2.1
PHASE 3.0 PRELIMINARY FIRE
ACCESS AND HOSE REACH EXHIBITPREST VUKSIC GREENWOOD
0'120'
SCALE 1"=60'
60'180'240'
%%ULEGEND
PORTOLA AVENUE
&
HAYSTACK ROAD
PORTOLA AVEDRIVE
SILVER SPUR TRL
N.T.S.
%%UVICINITY MAP
VINTAGE CLUB DRIVE
RESERVEMARRAKESH COUNTRY CLUB
IRONWOOD COUNTRY CLUB
THE
RESER
VE
THE VINTAGE CLUB
THE LIVING DESERT
\A1;16'\A1;16'\A1;16'\A1;16'\A1;16'LOWLANDS LION HABITAT
\pxqc;GRASSLANDS LION HABITAT
\pxqc;DELTA LION HABITAT
NEW LURIE PALM PATIO
\pxqc;CAVE
&
INDOOR SPACE
INDOOR SPACE
\A1;16'PROPOSED HYDRANTS
FIRE TRUCK STAGING
FIRE TRUCK HOSE PULL (150')
PROPOSED FIRE LANE\A1;16'MIN.000
PROPOSED FIRE SERVICE
FIRE TRUCK HOSE PULL (295')
1 STORY BUILDINGS
2 STORY BUILDINGS
EVENT BUILDING{(SPRINKLERED)}
\pxqc;LION CARE {\C17;(SPRINKLERED)}
SURROUND{(SPRINKLERED)}
\pxqc;SHADE STRUCTURE
\pxqc;SHADE STRUCTURE
\pxqc;SHADE STRUCTURE
\pxqc;SHADE STRUCTURE
\pxqc;SHADE STRUCTURE
\pxqc;SHADE STRUCTURE
\A1;54.84'\A1;82.31'R:\2244\ACAD\Exhibits\2244 Phase 3 Fire Access, Hydrant, & Hose Reach Exhibit.dwg, 5/8/2024 3:36:02 PM, lcantabrana, MSA Consulting, Inc.167
MH
MH
SPSP
M
M
MMMM
(382.33)FS
(382.23)FS
382.50
FS
382.66
FS
382.22
FS
381.66
FS
381.10
FS
381.05
FS
382.50FS
1.7%%%0.7%%%1.9%%%381.41FS
381.86FS
372.20
FS
371.75
FS
4.8%%%1.4%%%373.30
FS
4.7%%%
375.15
FS
374.03
FS
374.27
FS
1.9%%%1.9%%%1.4%%%374.30
FS 3.2%%%374.80
FS 1.9%%%375.80
FS4.7%%%375.20
FS
375.45
FS
374.15FS374.40FS3.0%%%
(370.70)
FS
376.00FS
374.50
FS
376.15
FS
377.28FS
377.53
FS
377.56FS
377.81FS
377.98
FS
378.19FS
378.23
FS
378.03
FS
378.91
FS379.43FS
379.25FS
380.75
FS
381.20
FS
(380.63)
FS
(380.47)
FS
381.00
FS
380.86FS
1.8%%%1.6%%%4.8%%%4.7%%%379.38FS
FS
378.46FS
2.0%%%1.7%%%
FF 379.80PE 379.3
FF 378.80PE 378.3
1.8%%%1.7%%%
1.6%%%2.5%%%4.7%%%
1.8%%%0.9%%%1.1%%%
1.3%%%
1.5%%%
0.9%%%
376.40
FS
377.35FS
377.44
FS
378.07FS
378.39FS
378.92
FS
378.73FS
378.74FS
378.90
FS
378.87
FS
379.08
FS
379.20FS
378.96
FS 380.50
FF
379.40FS FS
FS
FS
FSFS
FS
378.97FS
379.27
FS
378.67
FS378.53
FS
379.78FS
379.74FS
(379.73)
FS
377.16
FS
(379.77)
FS
379.43
FS
378.21FS 378.41FS
1.9%%%
379.35
FS
2.2%%%379.55
FS379.45
FS
(374.82)FS
379.69
379.22
379.55
379.80
379.67
1.4%%%
1.8%%%
3.1%%%
380.08
379.79
4.5%%%\pxqc;CHASE ADMIN BLDG
GAZELLE/
HORNBILLFF 382.70
PE 382.20
SPLASH ZONE
\pxqc;BIGHORN CAFE
\pxqc;INDOOR EVENT SPACE
\pxqc;LOWLANDS LION HABITAT
\pxqc;SURROUND
BIGHORN SHEEP HABITAT
NEW LURIE PALM PATIO
\pxqc;McMANUS
\pxqc;GIFT SHOP
\pxqc;MEERKAT CAFE
MODEL TRAIN EXHIBIT
\pxqc;EVENT BUILDING \pxqc;BASIN B
\pxqc;DELTA LION HABITAT
\pxqc;BOT. ELEV. 376.0
\pxqc;4:1 MAX. SLOPEFF (382.7)
FF (380.5)
FF (380.5)
FF (380.4)
FF (371.5)
Sheet:
Scale:
INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
A R C H I T E C T S • I N T E R I O R S
05/08/2024THE LIVING DESERT ZOO & GARDENS
PHASE 3 - EVENT CENTER 222028AS NOTEDMSA CONSULTING,INC.
C i vi l E n g i n e e r i n g L a n d S u r v ey i n g L a n d s c a p e A r c h i t e c t u r ePlanningEnvironmentalServicesDryUtilityCoordinationGIS
34200 Bob Hope Drive Rancho Mirage, CA 92270 | 760.320.9811 | MSAConsultinginc.com C3.0
PHASE 3.0 PRELIMINARY
GRADING EXHIBIT
PREST VUKSIC GREENWOOD
0'60'
SCALE 1"=30'
30'90'120'
HAYSTACK ROAD
PORTOLA AVEDRIVE
SILVER SPUR TRL
N.T.S.
%%UVICINITY MAP
VINTAGE CLUB DRIVE
RESERVEMARRAKESH COUNTRY CLUB
IRONWOOD COUNTRY CLUB
THE
RESER
VE
THE VINTAGE CLUB
THE LIVING DESERT
CITY OF PALM DESERTCITY OF INDIAN WELLSHAYSTACK ROAD
PORTOLA AVESILVER SPUR TRL
MARRAKESH COUNTRY CLUB
IRONWOOD COUNTRY CLUB
SEE SHEET C3.1
MATCHLINE
R:\2244\ACAD\Grading reliminary hase 3\2244 Preliminary Grading Plan Phase 3.dwg, 5/9/2024 11:45:51 AM, rreed, MSA Consulting, Inc.168
MH
MH
M M M M M
MM M M
BO
M
FF 382.70
PE 382.20
374.30
FS
3.2%%%
374.80
FS 1.9%%%375.80
FS4.7%%%376.80
FS
377.40
FS
377.65
FS
378.30
FS
379.25
FS1.9%%%2.0%%%1.5%%%1.6%%%379.80
FS
2.6%%%2.0%%%FF 378.10
PE 377.60
377.80FS
377.60FS
376.70
FS
(374.82)FS
1.7%%%\pxqc;CHASE ADMIN BLDG
GAZELLE/
HORNBILL
ORYX
HABITAT
\pxqc;CHASE ADMIN BLDG
FF 382.70
PE 382.20
\pxqc;EVENT BUILDING \pxqc;INDOOR EVENT SPACE
\pxqc;INDOOR EVENT SPACE
GRASSLANDS \pxqc;LION HABITAT
\pxqc;SURROUND
\pxqc;LION CARE
\pxqc;KEEPER CENTER AND ANIMAL CARE FACILITY
\pxqc;EXISTING MADEGASCAR PLANTINGSSANDCAT HABITAT
\pxqc;RETAIL BUILDING
\pxqc;EVENT BUILDING \pxqc;BASIN B
\pxqc;DELTA LION HABITAT
\pxqc;BOT. ELEV. 376.0
\pxqc;4:1 MAX. SLOPEFF (382.7)
FF (382.7)
FF (384.2)
FF (383.8)
Sheet:
Scale:
INFO@PVGARCHITECTS.COM | 760 . 779 . 5393 T
44530 SAN PABLO AVE, STE 200 | PALM DESERT, CA 92260
I I
WWW.PVGARCHITECTS.COM
A R C H I T E C T S • I N T E R I O R S
05/08/2024THE LIVING DESERT ZOO & GARDENS
PHASE 3 - EVENT CENTER 222028AS NOTEDMSA CONSULTING,INC.
C i vi l E n g i n e e r i n g L a n d S u r v ey i n g L a n d s c a p e A r c h i t e c t u r ePlanningEnvironmentalServicesDryUtilityCoordinationGIS
34200 Bob Hope Drive Rancho Mirage, CA 92270 | 760.320.9811 | MSAConsultinginc.com C3.1
PHASE 3.0 PRELIMINARY
GRADING EXHIBIT
PREST VUKSIC GREENWOOD
0'60'
SCALE 1"=30'
30'90'120'CITY OF PALM DESERTCITY OF INDIAN WELLSMATCHLINE
SEE SHEET C3.0
%%UESTIMATED EARTHWORK QUANTITIES
RAW QUANTITIES
SUBSIDENCE 719 648
RAW ADJUSTED 6,535 7,947
SHRINKAGE 1,686
IMPORT
TOTAL EARTHWORK 15,924 15,924
THE FOLLOWING FACTORS WERE USED IN THE PREPARATION OF THE EARTHWORK ANALYSIS:
SHRINKAGE: 17.5% (AVERAGED VALUE)
SUBSIDENCE: 0.20'