Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED SOLR24-0354 PLAN (2).pdf
MODULE WATT: 370 W (27)REC N-PEAK 2 REC370NP2 BLACK SYSTEM SIZE:9.99 KW DC (STC) :9.36 KW DC (PTC) :9.13 KW AC (CEC) (27)MICROINVERTERS: ENPHASE IQ8M-72-M-US (01)BATTERY: TESLA POWERWALL2 AZIMUTH:91°,181°,271° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/28/2026 PATSY ROOME RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:05/13/2024 SHEET NAME SHEET NUMBER 77676 ASHBERRY CT PALM DESERT,CA,92211 PHONE:(541)420-2723 CONSTRUCTION TYPE:V-B OCCUPANCY GROUP:R APN:632600065 SJ SUNLOGIX ENERGY 38698A EL VIENTO RD STE D PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 SCOPE OF WORK VICINITY MAP PROJECT SITE(33.7377083,-116.3630729) CODE COMPLIANCE GENERAL NOTES SHEET INDEX ROOF TILT:18° AZIMUTH:91°,181°,271° 1 STORY BUILDING 2022 CA BUILDING CODE 2022 CA PLUMBING CODE 2022 CA FIRE CODE 2022 CA RESIDENTIAL CODE 2022 CA MECHANICAL CODE 2022 CA ENERGY CODE 2022 CA ELECTRICAL CODE 2020 NATIONAL ELECTRICAL CODE 2022 ENERGY COMPLIANCE T-24 THIS PROJECT SHALL COMPLY WITH PV-1 COVER PAGE PV-2 PLOT PLAN PV-3 ROOF PLAN PV-4A - 4B ELECTRICAL LINE DIAGRAM PV-5 ATTACHMENT DETAIL PV-6A LIST OF PLACARDS PV-6B MONITORING CHART UL LISTED FOR ELECTRICAL AND FIRE SAFETY UL 1703 FOR MODULES AND UL 1741 FOR INVERTERS PER CITY SOLAR REQUIREMENTS NOTE: NO DISCHARGE OF ANY POLLUTANTS TO ANY STORM WATER DRAIN SYSTEM -SOLAR PHOTOVOLTAIC SYSTEM WUTH ENERGY STORAGE TO BE INSTALLED ON RESIDENTIAL STRUCTURE. -THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND LOCAL UTILITY.UTILITY SHALL BE NOTIFIED PRIOR TO ACTIVATION OF SOLAR PHOTOVOLTAIC INSTALLATION. -ALL EXTERNAL CONDUIT AND FITTINGS SHALL BE RAIN TIGHT AND SHOULD BE APPROVED TO USE IN WET AND DRY LOCATIONS. -ALL CONDUITS AND EQUIPMENTS SHALL BE PAINTED TO MATCH THE EXISTING BACKGROUND. -THE PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH CBC SECTION 1609 TO WITHSTAND A MINIMUM OF 97 MPH WIND LOAD -DESIGN COMPLYING WITH LATEST EDITION OF CALIFORNIA ELECTRICAL CODE, NEC AND ALL LOCAL ORDINANCES. -SHOULD USE PROPER GROUND BAR AND KITS FOR GROUNDING -THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING. MECHANICAL OR BUILDING ROOF VENTS. -THE DISTANCE BETWEEN BOTTOM OF PANEL TO THE TOP OF ROOF SHOULD BE MIN 4". -BACKFEED BREAKER SHOULD BE AT THE OPPOSITE END OF BUS BAR. -INSTALLERS TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. -SEE THE SPECS SHEETS FOR ADDITIONAL INFORMATION. -THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS OF LOCAL UTILITY. -ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. -A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA . -WORKING DISTANCE AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. -NO VENTS ( PLUMBING, MECHANICAL OR DORMER) TO BE COVERED OR REROUTED AROUND SOLAR MODULES.RELOCATION TO BE DONE ONLY AFTER APPROVAL. - ALL LABELS AND PLACARDS SHALL BE ATTACHED ACCORDING TO NEC AND THE LOCAL AHJ. -METAL CONDUIT AND ENCLOSURE SHALL BE USED WHERE PV SOURCE OR OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING. -ALL OUTDOOR EQUIPMENT SHALL BE MIN NEMA 3R RATED. -PER CALIFORNIA RESIDENTIAL CODE (CRC) SECTIONS R314 AND R315 SMOKE ALARM AND CARBON MONOXIDE DETECTORS ARE RETROFITTED INTO THE EXISTING DWELLINGS. -ALL PHOTOVOLTAIC EQUIPMENT SHALL BE LISTED BY RECOGNIZED TESTING LAB. -ALL SOLAR ENERGY SYSTEMS SHALL MEET APPLICABLE HEALTH AND SAFETY STANDARDS REQUIREMENTS IMPOSED BY THE CITY AND STATE OF CALIFORNIA. -SOLAR ENERGY SYSTEMS FOR PRODUCING ELECTRICITY SHALL MEET ALL APPLICABLE SAFETY AND PERFORMANCE STANDARDS ESTABLISHED BY CALIFORNIA ELECTRIC CODE,THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, ACCREDITED TESTING LABORATORIES SUCH AS UNDERWRITER LABORATORIES AND WHERE APPLICABLE, RULES OF PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY. -THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY QUALIFIED PERSONS. -WHEN BACKFEED BREAKER IS USED AS POINT OF INTERCONNECTION, BREAKER SHOULD NOT READ LINE AND LOAD. COVERSHEET STAMP PV1 77676 ASHBERRY CT PALM DESERT, CA 92211 77676 ASHBERRY CT PALM DESERT, CA 92211SYSTEM SIZE: 9.99 KW DC STC 9.36 KW DC PTC 9.13 KW AC CEC EQUIPMENT SUMMARY 27 REC N-PEAK 2 REC370NP2 BLACK 27 ENPHASE IQ8M-72-M-US (27X325/1000=8.78 KW INVERTER OUTPUT) 01 TESLA POWERWALL 2 BATTERY 27 x REC N-PEAK 2 REC370NP2 BLACK ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES 12 6 ' - 0 " 70'-0" 12 6 ' - 0 " 70'-0" 32 ' ± 4'± 21 ' ± 2'± 1' - 6 " 1' - 6 " 3'-0" 3'-0 " 3'-0 " 3'-0" MS P RS D LC BA T T GW Y JB CB MODULE WATT: 370 W (27)REC N-PEAK 2 REC370NP2 BLACK SYSTEM SIZE:9.99 KW DC (STC) :9.36 KW DC (PTC) :9.13 KW AC (CEC) (27)MICROINVERTERS: ENPHASE IQ8M-72-M-US (01)BATTERY: TESLA POWERWALL2 AZIMUTH:91°,181°,271° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/28/2026 PATSY ROOME RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:05/13/2024 SHEET NAME SHEET NUMBER 77676 ASHBERRY CT PALM DESERT,CA,92211 PHONE:(541)420-2723 CONSTRUCTION TYPE:V-B OCCUPANCY GROUP:R APN:632600065 SJ SUNLOGIX ENERGY 38698A EL VIENTO RD STE D PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 1 PLOT PLAN SCALE: 1/16"=1'-0"PV2 WIND SPEED:97 MPH EXPOSURE C RISK CATEGORY II PLOT PLAN PV2 LOCATIONS OF DC CONDUCTORS CONDUIT WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE OR HIP OR VALLEY AND FROM HIP OR VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE THE VENTILATION OPPORTUNITIES.CONDUIT RUNS BETWEEN SUB ARRAYS AND DC COMBINER BOX SHALL BE INSTALLED IN A MANNER THAT MINIMIZES THE TOTAL AMOUNT OF CONDUIT ON ROOF BY TAKING THE SHORTEST RUNS AND MINIMIZED IN THE PATHWAYS BETWEEN THE ARRAYS.DC WIRING SHALL BE INSTALLED IN A METALLIC CONDUIT OR RACEWAYS WHEN LOCATED WITHIN ENCLOSED SPACES IN A BUILDING. CONDUIT SHALL RUN ALONG THE BOTTOM OF THE LOAD BEARING MEMBERS ROOF COVERAGE ARRAY AREA 561.6 SQFT ROOF AREA 4025.0 SQFT %COVERAGE 14.0 %<33 BACKYARD SWIMMING POOL NOTE: A 36 INCH WIDE PATHWAY SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING ROOF 1 36" FIRE PATHWAY PER CFC 605.11.1.2.1 DRIVE WAY ROOF 1:12 MODULES ROOF TILT@18° AZIMUTH@91° (E)MAIN SERVICE PANEL AND (N)SOLAR BREAKER ROOF AZIMUTH 91°,181°,271° FROM NORTH BRANCH #1 ROOF ACCESS POINTS CRC R324.6 BRANCH #3 ROOF 2 ROOF 2:09 MODULES ROOF TILT@18° AZIMUTH@181° (E)WALL (E)WALL ROOF ACCESS POINTS CRC R324.6 36" FIRE PATHWAY PER CFC 605.11.1.2.1 (N)BATTERY, (N)GATEWAY, (N)COMBINER BOX AND (N)LOAD CENTER (IN GARAGE) ASHBERRY CT ROOF 3 ROOF 3:06 MODULES ROOF TILT@18° AZIMUTH@271° POINT LOAD CALCULATION PER ARRAY ITEM # OR LN FT WT (LBS)TOTAL WT (LBS) MODULES 27 47 1269 ROOF RAILS 184 0.5 92.0 MOUNTS 50 0.5 25.0 MICRO INVERTER/ POWER OPTIMIZER 27 2.4 64.8 TOTAL WEIGHT 1450.8 MODULE DIMENSIONS 69.10inx40.94 in 19.6 WEIGHT PER MOUNT 29.0 WEIGHT PER SQ FT(LBS/SQFT)2.7 WIND LOAD CALCS MODULES AND RACKING WEIGHT(W)1450.8 00000 LBS TOTAL MODULES AREA(A)529.2 SQFT WIND PRESSURE(PSF) P 35 PSF L=5/16" DIA LAG SCREWS 328 LBS/IN D=LAG SCREWS EMBEDEMENT 2.5 INCH QUANTITY OF LAG SCREWS(Q)100 QTY (N)RAPID SHUTDOWN SWITCH BRANCH #2 9'-5" 10 ' - 4 " 28 ' - 9 " 16'-7"5'-2" 39 ' - 1 1 " 9' - 1 " 11'-0"9'-5" 16 ' - 6 " 1' - 6 " MS P RS D LC BA T T GW Y JB 11'-0" 21'-1" 21'-1" CB 13 ± 3 - 1 / 2 " RO O F S L O P E 72" O.C MAX 1/3*L MAX TYP END MOUNTING CLIP,TYP MID MOUNTING CLIP,TYP SOLAR STANDARD RAIL TYP 1/3*L MAX TYP 13 ± 3 - 1 / 2 " MODULE WATT: 370 W (27)REC N-PEAK 2 REC370NP2 BLACK SYSTEM SIZE:9.99 KW DC (STC) :9.36 KW DC (PTC) :9.13 KW AC (CEC) (27)MICROINVERTERS: ENPHASE IQ8M-72-M-US (01)BATTERY: TESLA POWERWALL2 AZIMUTH:91°,181°,271° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/28/2026 PATSY ROOME RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:05/13/2024 SHEET NAME SHEET NUMBER 77676 ASHBERRY CT PALM DESERT,CA,92211 PHONE:(541)420-2723 CONSTRUCTION TYPE:V-B OCCUPANCY GROUP:R APN:632600065 SJ SUNLOGIX ENERGY 38698A EL VIENTO RD STE D PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 LEGEND JB INV SUB MSP ACD - JUNCTION BOX - INVERTER - AC DISCONNECT - MAIN SERVICE PANEL - SUB PANEL - ATTIC VENTS - DORMER VENTS -SKYLIGHT -CHIMNEY -PRODUCTION METERPM A/C -AIR CONDITON UNIT -SOLAR MODULES -FIRE ACCESS PATHWAY M -ELECTRIC METER CB -COMBINER BOX ROOF PLAN SCALE: 3/32"=1'-0"PV3 TYPICAL RACK MOUNT LAYOUT SCALE: 3/16"=1'-0"PV3 ROOF PLAN PV3-CONDUIT ON ROOF 1 2 50 QTY ATTACHMENT POINTS @ 72" O.C. MAX NOTE: PV BREAKER IN MAIN PANEL ACTS AS A MEANS OF AC DISCONNECT 690.15(D)(1) NOTE: INSTALL CONDUIT AT LEAST 7/8" ABOVE ROOF SURFACE. ROOF 1 ASHBERRY CT ROOF 2 69 . 1 0 " 40.94" REC N PEAK 2 REC370NP2 BLACK ROOF 1:12 MODULES ROOF TILT@18° AZIMUTH@91° (E)MAIN SERVICE PANEL AND (N)SOLAR BREAKER ROOF AZIMUTH 91°,181°,271° FROM NORTH ROOF 2:09 MODULES ROOF TILT@18° AZIMUTH@181° (N)BATTERY, (N)GATEWAY, (N)COMBINER BOX AND (N)LOAD CENTER (IN GARAGE) ROOF 3:06 MODULES ROOF TILT@18° AZIMUTH@271° (N)RAPID SHUTDOWN SWITCH ROOF 3 THWN-2 IN 3/4" EMT (3)AWG #8 L1 = BLACK L2 = RED N = WHITE (1)AWG #8 G = GREEN PV BREAKER 50 A DPB EATON BR250 30 A DPB FOR TESLA POWERWALL2 BR230, 10 KAIC (N)TESLA POWERWALL 2 - 14kWh UL 1973, UL1642, UL9540 NEMA 3R 3 FT THWN-2 IN 3/4" EMT AWG #10 L1 = BLACK L2 = RED N = WHITE AWG #8 G = GREEN (N)125 A RATED LOAD CENTER 120/240V FOR PARTIAL BACK UP LOADS TO PARTIAL LOADS (N)60A LOAD CENTER BREAKER (N)200A RATED TESLA GATEWAY WITH OPTIONAL BUS BAR 120/240V GEN/LOAD LUGS SUPPLY LUGS EXTERNAL RAPID SHUT DOWN 1 2" EMT (2)AWG#14 THWN-2 IN 1 " EMT (3)AWG #3 L1 = BLACK L2 = RED N = WHITE (1)AWG #8 G = GREEN BACK UP LOAD LISTS -KITCHEN LIGHTS -KITCHEN PLUGS -MICROWAVE -INTERNET EQUIPMENTS GARAGE DOOR OPENER -OTHER LIGHTS -ANY OTHER TESLA SITE CTS WIRES THWN-2 IN 3/4 " EMT (3)AWG #6 L1 = BLACK L2 = RED N = WHITE (1)AWG #8 G = GREEN === -+-+-+ BRANCH CIRCUIT 1=09 MODULES === -+-+-+ EGC BRANCH CIRCUIT 3=09 MODULES PHOTOVOLTAIC ARRAY === -+-+-+ BRANCH CIRCUIT 2=09 MODULES JUNCTION BOX N G (3) 20A DPB (N)125A RATED IQ COMBINER 4 X2-IQ-AM1-240-4 W/IQ ENVOY SOLAR PV USE ONLY ENPHASE IQ8M MICRO INVERTER THWN-2 3/4" EMT AWG#8 L1=BLACK L2=RED N=WHITE AWG#8 G=GREEN 90° C WET & DRY ENPHASE Q CABLE IN FREE AIR L1=BLACK L2=RED G=GREEN #6AWG CU BRANCH CIRCUIT #1,ISC=1.35A (N)175A DERATED MAIN DISCONNECT (E)200A MAIN SERVICE PANEL CUTLER-HAMMER BI-DIRECTIONAL UTILITY METER 1 PHASE, 3 WIRE 120/ 240 V (N) GATEWAY BREAKER 80A DPB LOCATED AT OPPOSITE END OF MAIN BREAKER SAME MODEL AS MSP NEW, IF NO EXISTING GROUNDING ELECTRODE MODULE WATT: 370 W (27)REC N-PEAK 2 REC370NP2 BLACK SYSTEM SIZE:9.99 KW DC (STC) :9.36 KW DC (PTC) :9.13 KW AC (CEC) (27)MICROINVERTERS: ENPHASE IQ8M-72-M-US (01)BATTERY: TESLA POWERWALL2 AZIMUTH:91°,181°,271° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/28/2026 PATSY ROOME RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:05/13/2024 SHEET NAME SHEET NUMBER 77676 ASHBERRY CT PALM DESERT,CA,92211 PHONE:(541)420-2723 CONSTRUCTION TYPE:V-B OCCUPANCY GROUP:R APN:632600065 SJ SUNLOGIX ENERGY 38698A EL VIENTO RD STE D PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 ELECTRICAL DIAGRAM PV4A NOTE: DERATE THE MAIN BREAKER FROM 200A TO 175A. LOAD CALCS ATTACHED (N)BRANCH CIRCUIT #1=09 MODULES (N)BRANCH CIRCUIT #2=09 MODULES (N)BRANCH CIRCUIT #3=09 MODULES NOTE: INSTALL HEAT ALARM INSIDE GARAGE. INSTALL BATTERY ON A SIDE WALL TO PROTECT IT FROM VEHICLE IMPACT. MODULE WATT: 370 W (27)REC N-PEAK 2 REC370NP2 BLACK SYSTEM SIZE:9.99 KW DC (STC) :9.36 KW DC (PTC) :9.13 KW AC (CEC) (27)MICROINVERTERS: ENPHASE IQ8M-72-M-US (01)BATTERY: TESLA POWERWALL2 AZIMUTH:91°,181°,271° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/28/2026 PATSY ROOME RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:05/13/2024 SHEET NAME SHEET NUMBER 77676 ASHBERRY CT PALM DESERT,CA,92211 PHONE:(541)420-2723 CONSTRUCTION TYPE:V-B OCCUPANCY GROUP:R APN:632600065 SJ SUNLOGIX ENERGY 38698A EL VIENTO RD STE D PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 ELECTRICAL DIAGRAM PV4B ELECTRICAL NOTES: 1.) ALL EQUIPMENT TO BE LISTED BY UL OR RECOGNIZED TESTING LABORATORY. 2.) ALL PLACARDS AND SIGNAGE REQUIRED BY LATEST EDITION OF CEC AND NEC WILL BE INSTALLED AS REQUIRED. 3.) ALL THE CONDUIT RUNS SHALL HAVE SUFFICIENT WEATHER PROOF JUNCTION BOXES/COMBINER BOXES. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC AND CEC 5.) ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION AND ALL THE MOUNTING METALLIC EQUIPMENT SHALL BE GROUNDED ACCORDING TO MANUFACTURER INSTRUCTIONS. 6.) ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC ENGRAVED OR MACHINE PRINTED LETTER IN A CONTRASTING COLOR .THE PLAQUE SHALL BE ATTACHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHODS AND SHALL BE UV RESISTANT IF EXPOSED TO DIRECT SUNLIGHT. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) AL THE PHOTOVOLTAIC SYSTEMS AND REQUIRED WIRINGS SHALL BE INSTALLED BY QUALIFIED PERSONNEL ONLY 9.) MICRO INVERTER SHALL CONTAIN GROUND FAULT DETECTION AND INTERRUPTION DEVICES. 10.) ALL WIRES ARE SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. 11.) IF THE EXISTING GROUNDING ELECTRODE SYSTEM CANNOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, CONTRACTOR SHALL INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AS PER CALIFORNIA RESIDENTIAL CODE CRC SECTIONS R14 AND R15 PROVIDE SMOKE ALARMS ON THE FOLLOWING LOCATIONS: 1.SMOKE ALARM IN ALL SLEEPING ROOMS. 2.CO ALARMS IN ALL SLEEPING ROOMS WITHIN WHICH FUEL BURNING APPLIANCES ARE INSTALLED. 3.SMOKE ALARMS AND CO ALARM IN AREA PRECEDING SLEEPING ROOMS (SUCH AS HALLWAY),AND 4.SMOKE ALARM AND CO ALARM ON EACH STORY LEVEL OF THE DWELLING INCLUDING BASEMENTS AND HABITABLE ATTIC ROOMS MICROINVERTER SPECIFICATIONS MANUFACTURER / MODEL #ENPHASE IQ8M-72-M-US NOMINAL AC POWER 325 W NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 1.35 A (N)BATTERY SPECIFICATIONS MANUFACTURER / MODEL #TESLA POWERWALL2 NOMINAL AC POWER 5.0 KW NOMINAL OUTPUT VOLTAGE 240V NOMINAL CURRENT 21 AMPS TOTAL ENERGY 14 KWHR USABLE ENERGY 13.5 KWHR DIMENSIONS 29.6"X45.3"X5.75" SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #REC370NP2 BLACK VMP 34.7V IMP 10.68A VOC 41.1V ISC 11.41A TEMP. COEFF. VOC -0.26%/°K MODULE DIMENSION 69.10"L x 40.94"W x 1.20"D (In Inch) PTC RATING 346.68W MICROINVERTERS MAX OUTPUT POWER=325W AC 1.35x9=12.15A PER BRANCH CIRCUITS #1, #2, #3 MAX BRANCH AC REQUIRED CONDUCTOR AMPACITY (1.35X9X1.25)=15.19A AWG#10 DERATED AMPACITY 40X0.7X0.65=18.20A 18.20A>15.19A, THEREFORE AC WIRE SIZE IS VALID TOTAL OUTPUT CURRENT FROM COMBINER BOX 1.35X27=36.45A AC REQUIRED CONDUCTOR AMPACITY=36.45X1.25=45.56A AWG#8 DERATED AMPACITY 55x0.87x1.0=47.85A 47.85A>45.56A> THEREFORE AC WIRE SIZE IS VALID OUTPUT CURRENT FROM TESLA=21.00A TOTAL CURRENT FROM BACK UP GATEWAY 36.45A+21.00A=57.45A AC REQUIRED CONDUCTOR AMPACITY=57.45AX1.25=71.81A AWG#4 DERATED AMPACITY 95X0.87x1.0=82.65A 82.65A>71.81A, THEREFORE AC WIRE SIZE IS VALID USE 705.13 POWER CONTROL SYSTEM PCS PCS CONTROLLED CURRENT SETTING:160A(200*0.8). MEANS IF THE COMBINED GRID PLUS SOLAR PLUS ESS EXCEEDS 140A THEN THE ESS SYSTEMS BEGINS TO CUTRAIL POWER TO STAY WITHIN 160A LIMIT THE MAX OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY.REFER TO THE MANUFACTURERS INSTRUCTION FOR MORE INFORMATION. 18" 4 " 1 8 ° 5'-9" MAX 5'-8" 5'-8" MODULE WATT: 370 W (27)REC N-PEAK 2 REC370NP2 BLACK SYSTEM SIZE:9.99 KW DC (STC) :9.36 KW DC (PTC) :9.13 KW AC (CEC) (27)MICROINVERTERS: ENPHASE IQ8M-72-M-US (01)BATTERY: TESLA POWERWALL2 AZIMUTH:91°,181°,271° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/28/2026 PATSY ROOME RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:05/13/2024 SHEET NAME SHEET NUMBER 77676 ASHBERRY CT PALM DESERT,CA,92211 PHONE:(541)420-2723 CONSTRUCTION TYPE:V-B OCCUPANCY GROUP:R APN:632600065 SJ SUNLOGIX ENERGY 38698A EL VIENTO RD STE D PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 ATTACHMENT DETAILS PV5A 1 ATTACHMENT TYPE: PEGASUS S TILE REPLACEMENT MOUNT (CONCRETE S TILE ROOF) SCALE: NTSPV5 2X4 TRUSSES @24"O.C (E) 1/2" CDX PLYWOOD (2) 5/16"x3-1/2" SS LAG BOLT@ 6' O.C Max. OVER EXISTING SHEATHING AND ROOF TRUSSES AS SHOWN. MIN 2-1/2" PENETRATION IRON RIDGE XR10 RAIL (E)CONCRETE S TILE ROOF MAX 1 LAYER MASTIC, MESH AND MASTIC FLASHING PEGASUS S TILE REPLACEMENT MOUNT 2X4 TRUSS@ 24" O.C SOLAR PANEL PORTRAIT MS P RS D LC BA T T GW Y JB CB MODULE WATT: 370 W (27)REC N-PEAK 2 REC370NP2 BLACK SYSTEM SIZE:9.99 KW DC (STC) :9.36 KW DC (PTC) :9.13 KW AC (CEC) (27)MICROINVERTERS: ENPHASE IQ8M-72-M-US (01)BATTERY: TESLA POWERWALL2 AZIMUTH:91°,181°,271° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/28/2026 PATSY ROOME RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:05/13/2024 SHEET NAME SHEET NUMBER 77676 ASHBERRY CT PALM DESERT,CA,92211 PHONE:(541)420-2723 CONSTRUCTION TYPE:V-B OCCUPANCY GROUP:R APN:632600065 SJ SUNLOGIX ENERGY 38698A EL VIENTO RD STE D PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 PLACARDS PV6A POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCE WITH DISCONNECT LOCATED AS SHOWN CAUTION PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR ADHESIVE.WARNING LABELS WHITE LETTERS ON RED BACKGROUND AND NON-BOLD ARIAL OR SIMILAR FONT.MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (N)PHOTOVOLTAIC SOLAR ON ROOF MAIN SERVICE PANEL PV BREAKER AND RAPID SHUTDOWN SWITCH ASHBERRY CT BATTERY, LOAD CENTER AND GATEWAY (IN GARAGE) ! WARNING ! ELECTRIC SHOCK HAZARD THE TERMINALS ON LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION (690.13(B) CEC AT ALL "J" BOXES, COMBINER BOX,ENCLOSURES/EMT ENCLOSURES/DISCONNECTS ! WARNING ! POWER SOURCE OUTPUT CONNECTIONS, DONOT RELOCATE THIS OVER CURRENT DEVICE NEC 705.12 (B)(2)(3)(b)PLACED ON MAIN PANEL/BREAKER LOCATION PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE PLACED ON SOLAR +ESS BREAKER ! WARNING ! ! WARNING ! PHOTOVOLTAIC POWER SOURCE ON ALL CONDUITS SPACED AT MAX 10 FT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 57.45 A NOMINAL OPERATING AC VOLTAGE 240 V CEC 690.54 PLACED ON MAIN PANEL AND GATEWAY X2 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS WITHIN 3 FT OF MAIN PANEL/AC DISCONNECT WARNING MAIN BREAKER SIZE IS REDUCED TO 175A FOR PHOTOVOLTAIC CIRCUIT. DO NOT INCREASE MAIN BREAKER SIZE. AT SERVICE EQUIPMENT LOCATION IF DERATING THE MAIN BREAKER CEC 690.56 C(3) PLACED WITHIN 3 FT OF RAPID SHUT DOWN SWITCH DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ! WARNING ! PHOTOVOLTAIC POWER SOURCE CEC 690.31 (G)3-4 ON ALL EMT CONDUIT, ENCLOSURE,COMBINER BOXES,DISCONNECTS ! WARNING ! TURN OFF PHOTOVOLTAIC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27 C, COMBINER BOX, ENCLOSURE/CONDUIT ENCLOSURE/DISCONNECT RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM ENERGY STORAGE SYSTEM DISCONNECT NOMINAL ESS AC VOLTAGE 240 V NOMINAL ESS DC VOLTAGE 400V AVAILABLE FAULT CURRENT DERIVED FROM ESS 32A DATE CALCULATION PERFORMED 03/06/2024 BATTERY CHEMISTRY: LITHIUM ION PLACED ON RSD SWITCH PCS CONTROLLED CURRENT SETTING:160A THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARD THE MAIN PANEL IS CONTROLLED ELECTRONICALLY.REFER TO THE MANUFACTURER INSTRUCTIONS FOR MORE INFORMATION. AT SERVICE EQUIPMENT LOCATION ! WARNING ! THREE POWER SOURCE SECOND SOURCE IS PV,THIRD SOURCE IS ESS CEC 705.12 D(3),NEC 690.59 ON MAIN PANEL ! MS P RS D LC BA T T GW Y JB CB MODULE WATT: 370 W (27)REC N-PEAK 2 REC370NP2 BLACK SYSTEM SIZE:9.99 KW DC (STC) :9.36 KW DC (PTC) :9.13 KW AC (CEC) (27)MICROINVERTERS: ENPHASE IQ8M-72-M-US (01)BATTERY: TESLA POWERWALL2 AZIMUTH:91°,181°,271° ROOF TILT:18° MOUNTING HEIGHT:1-STORY SIGNATURE AND SEAL X STATE LICENSE#LICENSE CLASS C-46 EXPIRE DATE 02/28/2026 PATSY ROOME RESIDENCE JURISDICTION PALM DESERT CITY OF DRAWING INFORMATION REV # DESCRIPTION DATE PERMITTING DRAWN BY REVISION PROJECT NAME AND ADDRESS DATE:05/13/2024 SHEET NAME SHEET NUMBER 77676 ASHBERRY CT PALM DESERT,CA,92211 PHONE:(541)420-2723 CONSTRUCTION TYPE:V-B OCCUPANCY GROUP:R APN:632600065 SJ SUNLOGIX ENERGY 38698A EL VIENTO RD STE D PALM DESERT,CA,92211 PHONE:760-844-6507 CONTRACTOR:ZACHARY N GAMEZ 1063414 MONITORING CHART PV6B OPTIMIZERS/MICRO-INVERTERS CHART wp Power ELIGIBLE PREMIUM FULL BLACK MONO N-TYPE SOLAR PANELS rec N-Peak 2 Black Series MONO N-TYPE: THE MOST EFFICIENT C-SI TECHNOLOGY SUPER-STRONG FRAME UP TO 7000 PA SNOW LOAD FEATURING REC’S PIONEERING TWIN DESIGN FLEXIBLE INSTALLATION OPTIONS NO LIGHT INDUCED DEGRADATION 370 BIFACIAL CELLS CAN PRODUCE ENERGY FROM BOTH SIDES Re f : P M - DS - 1 1 - 0 4 - Re v - D 03 . 2 2 www.recgroup.com Sp e c i f i c a t i o n s s u b j e c t t o c h a n g e w i t h o u t n o t i c e . Measurements in mm [in] LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: Irradiance (W/m²) Re l . E f f i c i e n c y ( % ) Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 REC N-Peak 2 Black Series Product SPECIFICATIONS GENERAL DATA Cell type:120 half-cut bifacial mono c-Si n-type cells 6 strings of 20 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) with silver support bars Junction box:3-part, 3 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (4 mm²) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) in accordance with EN 50618 Dimensions:69.1 x 40.94 x 1.2 in (19.70 ft2) / 1755 x 1040 x 30 mm (1.83 m2) Weight:44.0 lbs (20.0 kg) Origin:Made in Singapore WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply TEMPERATURE RATINGS * Nominal Module Operating Temperature:44.3°C (±2 °C) Temperature coefficient of PMAX:-0.34 %/°C Temperature coefficient of VOC:-0.26 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 61730 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) ISO 14001, ISO 9001, IEC 45001, IEC 62941 DELIVERY INFORMATION Panels per pallet:33 Panels per 40 ft GP/high cube container:858 (26 pallets) Panels per 53 ft truck:924 (28 pallets) MAXIMUM RATINGS Operational temperature:-40 ... +85°C Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/ft2)* Maximum test load (rear):- 4000 Pa (83.5 lbs/ft2)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) S T C N M O T ELECTRICAL DATA Product Code*: RECxxxNP2 Black Power Output - PMAX (Wp) 350 355 360 365 370 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 33.1 33.5 33.9 34.3 34.7 Nominal Power Current - IMPP (A) 10.57 10.60 10.62 10.65 10.68 Open Circuit Voltage - VOC (V) 40.6 40.7 40.8 40.9 41.1 Short Circuit Current - ISC (A) 11.25 11.27 11.31 11.36 11.41 Panel Efficiency (%) 19.1 19.4 19.7 20.0 20.3 Power Output - PMAX (Wp)264 268 272 276 280 Nominal Power Voltage - VMPP (V) 31.0 31.3 31.7 32.1 32.5 Nominal Power Current - IMPP (A) 8.54 8.56 8.58 8.60 8.63 Open Circuit Voltage - VOC (V) 38.0 38.1 38.2 38.2 38.4 Short Circuit Current - ISC (A) 9.06 9.10 9.13 9.18 9.22 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GR GR GR GR 11±0.2 [0.43 ±0.1] 6. 6 ± 0 . 2 [ 0 . 2 6 ± 0 . 1 ] 20.5±0.5 [0.8 ±0.02] GR 638 ±1 [25.1 ±0.04] 30 [1.2] 22.5 [0.9] 28 [1.1] 1755±2.5 [69.10 ±0.1] 845 [33.27] 156 [6.14] 156 [6.14] 455 [17.91] 99 9 [ 3 9 . 3 3 ] 1100 [43.3] 5.5±0.2 [0.22±0.01] 1200 [47.2] 10 4 0 ± 2 . 5 [ 4 0 . 9 4 ± 0 . 1 ] 17 [ 0 . 7 ] 45 [1.8] DATA SHEET IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Easy to install • Lightweight and compact with plug-n- play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down* • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high-powered PV modules Microgrid-forming • Complies with the latest advanced grid support** • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) and IEEE 1547:2018 (UL 1741-SB) Note: IQ8 Microinverters cannot be mixed together with previous generations of Enphase microinverters (IQ7 Series, IQ6 Series, etc) in the same system. © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 Microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. *Only when installed with IQ System Controller 2, meets UL 1741. **IQ8M and IQ8A support split-phase, 240V installations only. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL listed as PV Rapid Shutdown Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Connect PV modules quickly and easily to the IQ8 Series Microinverters that has integrated MC4 connectors. IQ8MA-MC4-12A-DS-0080-02-EN-US-2022-12-12 (1) Pairing PV modules with wattage above the limit may result in additional clipping losses. See the compatibility calculator at https://link.enphase.com/module-compatibility. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8M and IQ8A Microinverters INPUT DATA (DC)IQ8M-72-M-US IQ8A-72-M-US Commonly used module pairings1 W 260 – 460 295 – 500 Module compatibility 54-cell / 108 half-cell, 60-cell / 120 half-cell, 66-cell / 132 half-cell and 72-cell / 144 half-cell MPPT voltage range V 30 – 45 32 – 45 Operating range V 16 – 58 Min. / Max. start voltage V 22 / 58 Max. input DC voltage V 60 Max. continuous input DC current A 12 Max. input DC short-circuit current A 25 Max. module Isc A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1 x 1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8M-72-M-US IQ8A-72-M-US Peak output power VA 330 366 Max. continuous output power VA 325 349 Nominal (L-L) voltage / range2 V 240 / 211 – 264 Max. continuous output current A 1.35 1.45 Nominal frequency Hz 60 Extended frequency range Hz 47 – 68 AC short circuit fault current over 3 cycles Arms 2 Max. units per 20 A (L-L) branch circuit3 11 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.8 97.7 CEC weighted efficiency %97.5 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40°C to +60°C (-40°F to +140°F) Relative humidity range 4% to 100% (condensing) DC Connector type Stäubli MC4 Dimensions (H x W x D)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.1 kg (2.43 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN / CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1- 2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8MA-MC4-12A-DS-0080-02-EN-US-2022-12-12 TESLA.COM/ENERGY POWERWALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, time-based control, and backup. Powerwall’s electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240 V Feed-In Type Split Phase Grid Frequency 60 Hz Total Energy1 14 kWh Usable Energy1 13.5 kWh Real Power, max continuous 5 kW (charge and discharge) Real Power, peak (10 s, off-grid/backup)7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10 s, off-grid/backup)7.2 kVA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split-Phase Loads 100% Power Factor Output Range +/– 1.0 adjustable Power Factor Range (full-rated power)+/– 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency1,2 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Optimum Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C (86°F) MECHANICAL SPECIFICATIONS Dimensions 1150 mm x 755 mm x 155 mm (45.3 in x 29.7 in x 6.1 in) Weight 125 kg (276 lbs) Mounting options Floor or wall mount 1 Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2 AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) 155 mm (6.1 in) 1150 mm (45.3 in) 755 mm (29.7 in) TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS PARTIAL HOME BACKUP WHOLE HOME BACKUP Main panelSub panel Solar Home loads Solar inverter Utility meter GridBackup Gateway Powerwall Backup loads Optional NA - BACKUP - 2018-01-30 Utility meter GridBackup Gateway including service disconnect Main panel Solar Whole home backup Solar inverter Powerwall Optional TESLA.COM/ENERGY Backup Gateway POWERWALL 740 mm (29.1 in) 378 mm (14.9 in) 129 mm (5.1 in) The Backup Gateway for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup. The Backup Gateway controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a circuit breaker, the Backup Gateway can be installed at the service entrance. The Backup Gateway communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP44 MECHANICAL SPECIFICATIONS Dimensions 740 mm x 378 mm x 129 mm (29.1 in x 14.9 in x 5.1 in) Weight 16.4 kg (36 lbs) Mounting options Wall mount PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)230 V, 120/240 V Feed-In Type Single & Split Phase Grid Frequency 50 and 60 Hz Disconnect Current 200 A Maximum Input Short Circuit Current 10 kA Overcurrent Protection Device1 100–200 A; Service Entrance Rated Overvoltage Category Category IV AC Meter Revenue grade (+/– 1%) Connectivity Ethernet, Cellular (3G), Wi-Fi User Interface Tesla App Operating Modes Support for solar self-consumption, time-based control, and backup Backup Operation Automatic disconnect for seamless backup transition Modularity Supports up to 10 AC-coupled Powerwalls Warranty 10 years COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, IEC 62109-1, CSA C22.2.107.1 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003, IEC 61000-6-3, EN 55024, EN 301489-1, EN 301489-7, EN 301489-17 Environmental RoHS Directive 2011/65/EU, WEEE Directive 2012/19/EU, Battery Directive 2006/66/EC REACH Regulation Seismic AC156, IEEE 693-2005 (high) 2018-02-13 1 Circuit breaker required for installation at service entrance. Tech Brief Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. XR Rails® are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount of installation time. XR Rail® Family Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails® is specially designed to increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs Roof Mount utilizes XR Rails, along with optional all-in-one attachments, to secure systems flush against residential roofs. Corrosion-Resistant Materials XR Rails® are compatible with FlashFoot® and other pitched roof attachments. IronRidge® offers a range of tilt leg options for flat roof mounting applications. All XR Rails® are made of 6000-series aluminum alloy, then protected with an anodized finish. Anodizing prevents surface and structural corrosion, while also providing a more attractive appearance. XR Rail® Family The XR Rail® Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail® to match. © 2023 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.22 Tech Brief Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria: ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF)Wind (MPH)4’5’ 4”6’8’10’12’ None 90 120 140 XR10 XR100 XR1000 160 20 90 120 140 160 30 90 160 40 90 160 80 160 120 160 XR100 XR100 is a residential and commercial mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 10 feet. • 10’ spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR10 XR10 is a sleek, low-profile mounting rail, designed for regions with light or no snow. It achieves spans up to 6 feet, while remaining light and economical. • 6’ spanning capability • Moderate load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It’s built to handle extreme climates and spans up to 12 feet for commercial applications. • 12’ spanning capability • Extreme load capability • Clear anodized finish • Internal splices available .Xefpi mw Tier[ [s fi e wmTtpmÄih wter glev[ Msv gsrzi`mrk kirivep vemp getefmpm[miw2 <wi ettvszih giv[mÄge[msr pi[[ivw Msv eg[yep hiwmkr kymhergi2 EASIER TILE INSTALLATIONS Pegasus Solar’s Tile Replace Mount eliminates grinding of tiles and gives you extra tiles to replace broken tiles. Reduce fatigue and increase crew productivity by making installations easier and faster. A BETTER DAY ON THE JOB TILE REPLACE MOUNT 25-year Warranty Manufactured with advanced materials and coatings to outlast the roof itself Universal Fits most tile thickness and batten or batten-less roofs. S-flashing works on concrete and clay tiles. Compatible with all rails. Code Compliant Fully IBC/CBC Code Compliant Exceeds ASCE 7-16 Standards Tested to AC286 Kit Packaging Flashing kit includes flashing, post, mounting bolt and EPDM boot. Sled kit includes universal sled, SS lags and base flashing (optional). No grinding or cutting tiles Flashing slides into place then post twist-locks into position Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804 510.210.3797 www.pegasussolar.com Gain one roof tile per mount. Eliminate trips to the tile yard to purchase replacement tiles SKU PSTR-FWB0 PSTR-SB00 Tile Type Flat-Tile S-Tile & Clay Tile W-Tile Any Hardware Included Flashing, Post, Mounting Bolt, EPDM Boot Install Application Rails Certifications IBC, ASCE/SEI 7-16, AC286 Material Painted Galvalume Plus Flashing, Aluminum Post Aluminum Sled, Aluminum Base Flashing Kit Quantity 12 12 Boxes Per Pallet 36 36 TILE REPLACE MOUNT Patents Pending. All rights reserved. © 2020 Pegasus Solar Inc. 1.Remove tile to be replaced and locate rafter. 3.Slide replacement flashing under left and up-roof tiles, ensuring post hole lines up with sled channel. 2.Install sled over optional base flashing and drive lag screws to required embed- ment. Waterproof per all applicable codes and standards as required by the AHJ. 4.Insert post with T-bolt into sled channel. Once engaged, rotate post clockwise to tighten T-bolt. Install EPDM boot over post and snug to flashing. Specifications Sled Kit (Universal) Flat Tile Replace Kit S Tile Replace Kit W Tile Replace Kit Sled Kit Sled, 5/16” SS Lags, Base Flashing 15" 17" 2.2" 13" 18"4" 14" 18"3.5" Pegasus Solar Inc 100 West Ohio Avenue, Richmond, CA 94804 510.210.3797 www.pegasussolar.com 1.5" 4.1" 1.5" 5.7" 1.5" 4.7" 0.6" 4.1" 8.5" 6.8" 12.7" 1.6" Tile Replace Flashing Kit (Flat, S & W) PSTR-FSB0 PSTR-FFB0 STEP 1 Unit # OF EACH Multiplying factor Breaker size VA/WATTS OTHER LOADS ART 220.14 INSIDE SQUARE FOOTAGE 2601 Sq ft GENERAL LIGHTING 3 7803 SMALL APPLIANCE AND LAUNDARY CURCUITS 2 1500 3000 OTHER LAODS DISH WASHER 1 1 20 1920 Microwave 1 1 20 1920 REFRIGERATOR 1 1 20 1920 WATER HEATER 0 1 40 0 DRYER 1 1 30 5760 1 POLE OVEN/RANGE 1 1 40 7680 2 POLE GARBAGE DISOSAL 1 1 20 1920 SUB PANEL 0 1 60 0 POOL AND OTHERS 1 1 15 2880 2 pole 34803 FIRST 10,000 VA X100%10000 VA 1 10000 REMAINING VA X 40 %24803 VA 0.4 9921.2 TOTAL 1 19921.2 STEP2 HEATING OR AC LOAD HEATING UNIT 3 OR LESS 0 0 0 AC UNIT 1 2 30 11520 AC UNIT 2 0 0 0 AC UNIT 3 0 0 0 OTHER LOADS EV CHARGER 1 40 7680 OTHER LOADS RV 240 0 0 0 TOTAL 2 19200 TOTAL VA AMPERE LOAD 39121.2 VA TOTAL AMPERE LOAD 163.005 A MIN SERVICE REQUIREMENT 175 A MIN SERVICE PROVIDED 200 A APPLYING DEMAND FACTOR ART 220.82 LOAD CALCULATION SINGLE FAMILY DWELLING (NEW OR EXISTING) CUSTOMER NAME:PATSY ROOME 77676 Ashberry Ct Palm Desert, CA 92211, USA Updated June 2021 These criteria are intended for expedited solar permitting process. If any items are UNCHECKED, revise design to fit within Eligibility Checklist, otherwise permit application must go through standard process which is (10 Business Day initial review/7 Business Day Follow-up Review) 1. General Requirements ☐ The photovoltaic system size is 30kW AC CEC rating or less. ☐ The solar array is roof-mounted on a one- or two-family dwelling unit or permitted accessory structure. ☐ The photovoltaic system is utility interactive. ☐ Permit application and declaration is completed and attached. 2. Planning Department Requirements ☐ Existing MPU Amps Doubling, e.g. 100 to 200 OR 125 to 225. PLANNING WILL NEED TO REVIEW. ☐ Maximum height of “tilted” panels shall not exceed eighteen (18) inches. ☐ All wires shall be strapped to the modules/racking system. No loose or hanging wires are permitted. ☐ The racking system shall match the module frame and shall be a color compatible with the architectural character of the home or building. ☐ Modules shall be flush with one another and gaps between panels shall be minimized. ☐ Screening of panels is not required. Any screening material proposed shall be compatible with the architectural character of the home of building. 3. Electrical Requirements ☐ No more than four photovoltaic module strings are connected to each Maximum Power Point Tracking (MPPT) input where source circuit fusing is included in the inverter: 1) No more than two strings per MPPT input where source circuit fusing is not included 2) Fuses (if needed) are rated to the series fuse rating of the PV module 3) No more than one non-inverter-integrated DC combiner is utilized per inverter ☐ For central inverter systems: No more than two inverters are utilized. ☐ The PV system is connected to the load side of the utility distribution equipment. ☐ A Solar PV Standard Plan and supporting documentation is completed and attached. 4. Structural Requirements ☐ A completed Structural Criteria and supporting documentation is attached Wind and Seismic (if required). 5. Fire Safety Requirements ☐ Clear access pathways provided. ☐ Fire classification photovoltaic system is provided. ☐ All required marking and labels are provided. ☐ A diagram of the roof layout of electrical panels, modules, clear access pathways and approximate locations of electrical disconnecting means and roof access points are completed and attached. I understand and affirm that the above information regarding the solar photovoltaic is true and accurate. If during the inspection process any deviation in this scope will result in stop work and full plan review. In the event a project requires supplemental plan reviews, a plan review fee of $168.00 per hour (with one-half hour minimum) will be collected from the applicant. Applicant Signature: _____________________________________Date:_______________ Project Address: ________________________________________________________ Eligibility Checklist Expedited Solar Photovoltaic Permitting for One- and Two-family Dwellings