HomeMy WebLinkAbout2024-11-19 PC Regular Meeting Agenda Packet
PLANNING COMMISSION
CITY OF PALM DESERT
MEETING AGENDA
Tuesday, November 19, 2024
6:00 p.m.
Council Chamber, City Hall
73-510 Fred Waring Drive
Palm Desert, California
Pursuant to Assembly Bill 2449, this meeting will be conducted as a hybrid meeting and there will be
in-person access to this location.
To participate via Zoom, use the following link: https://palmdesert.zoom.us/j/84739707419 or
call (213) 338-8477, Zoom Meeting ID: 847 3970 7419
•
Written public comment may also be submitted to PlanningCommission@palmdesert.gov. E-
mails received by 3:00 p.m. prior to the meeting will be distributed to the Commission. Any
correspondence received during or after the meeting will be distributed to the Commission as
soon as practicable and retained for the official record. Emails will not be read aloud except
as an ADA accommodation.
•
Pages
1.CALL TO ORDER
2.ROLL CALL
3.PLEDGE OF ALLEGIANCE
4.NONAGENDA PUBLIC COMMENTS
This time has been set aside for the public to address the Planning Commission
on issues that are not on the agenda for up to three minutes. Speakers may
utilize one of the three options listed on the first page of the agenda. Because
the Brown Act does not allow the Planning Commission to act on items not listed
on the agenda, members may briefly respond or refer the matter to staff for a
report and recommendation at a future meeting.
5.CONSENT CALENDAR
All matters listed on the Consent Calendar are considered routine and may be
approved by one motion. The public may comment on any items on the Consent
Agenda within the three-minute time limit. Individual items may be removed by
the Planning Commission for a separate discussion.
RECOMMENDATION:
To approve the consent calendar as presented.
5.a APPROVAL OF MINUTES 5
RECOMMENDATION:
Approve the Minutes of October 29, 2024.
6.ACTION CALENDAR
The public may comment on individual Action Items within the three-minute time
limit. Speakers may utilize one of the three options listed on the first page of the
agenda.
None.
7.PUBLIC HEARINGS
Anyone who challenges any hearing matter in court may be limited to raising
only those issues he or she raised at the public hearing described herein, or in
written correspondence delivered to the Planning Commission at, or prior to, the
public hearing. Remarks shall be limited to a maximum of three minutes unless
the Planning Commission authorizes additional time.
7.a CONSIDERATION TO ADOPT A NOTICE OF EXEMPTION AND
APPROVE A CONDITIONAL USE PERMIT AMENDMENT TO ALLOW THE
EXPANSION OF A RESTAURANT AT 77734 COUNTRY CLUB DRIVE
9
RECOMMENDATION:
Adopt Planning Commission Resolution No. 2886 entitled, “A RESOLUTION
OF THE PLANNING COMMISSION OF THE CITY OF PALM DESERT,
CALIFORNIA, APPROVING A CONDITIONAL USE PERMIT AMENDMENT
FOR THE EXPANSION OF AN EXISTING RESTAURANT AT 77734
COUNTRY CLUB DRIVE, SUITE F1, AND ADOPTING A NOTICE OF
EXEMPTION IN ACCORDANCE WITH THE CALIFORNIA
ENVIRONMENTAL QUALITY ACT (CEQA).”
8.INFORMATIONAL REPORTS & COMMENTS
8.a SUMMARY OF CITY COUNCIL ACTIONS
8.b COMMITTEE MEETING UPDATES
8.b.1 Cultural Arts Committee
8.b.2 Parks and Recreation Committee
8.c PLANNING COMMISSIONERS
8.d CITY STAFF
8.e ATTENDANCE REPORT 53
Planning Commission MeetingSeptember 3, 2024
2
9.ADJOURNMENT
The next Regular Meeting will be held on December 3, 2024, at 6:00 p.m.
10.PUBLIC NOTICES
Agenda Related Materials: Pursuant to Government Code §54957.5(b)(2) the
designated office for inspection of records in connection with this meeting is the
Office of the City Clerk, Palm Desert Civic Center, 73-510 Fred Waring Drive,
Palm Desert. Staff reports for all agenda items considered in open session, and
documents provided to a majority of the legislative bodies are available for
public inspection at City Hall and on the City’s website at www.palmdesert.gov.
Americans with Disabilities Act: It is the intention of the City of Palm Desert to
comply with the Americans with Disabilities Act (ADA) in all respects. If, as an
attendee or a participant at this meeting, or in meetings on a regular basis, you
will need special assistance beyond what is normally provided, the City will
attempt to accommodate you in every reasonable manner. Please contact the
Office of the City Clerk, (760) 346-0611, at least 48 hours prior to the meeting to
inform us of your needs and to determine if accommodation is feasible.
AFFIDAVIT OF POSTING
I hereby certify under penalty of perjury under the laws of the State of California
that the foregoing agenda for the Planning Commission was posted on the City
Hall bulletin board and City website not less than 72 hours prior to the meeting.
/S/ Michelle Nance
Deputy Clerk II
Planning Commission MeetingSeptember 3, 2024
3
4
PLANNING COMMISSION
CITY OF PALM DESERT
SPECIAL MEETING MINUTES
October 29, 2024, 6:00 p.m.
Present: Commissioner Nancy DeLuna, Commissioner John Greenwood,
Commissioner Joseph Pradetto, Chair Ron Gregory
Absent: Vice-Chair Lindsay Holt
Staff Present: Director of Development Services Richard Cannone, Principal
Planner Nick Melloni, Principal Planner Carlos Flores, Planning
Technician Kayleen Aguirre, Deputy City Attorney Oscar Verdugo,
Recording Secretary Michelle Nance
1. CALL TO ORDER
A Special Meeting of the Planning Commission was called to order by Chairman Gregory
on Tuesday, October 29, 2024, at 6:00 p.m. in the Council Chamber, City Hall, located at
73-510 Fred Waring Drive, Palm Desert, California.
2. ROLL CALL
3. PLEDGE OF ALLEGIANCE
Commissioner DeLuna led the Pledge of Allegiance.
4. NON-AGENDA PUBLIC COMMENTS
None.
5. CONSENT CALENDAR
Motion by: Commissioner Pradetto
Seconded by: Commissioner DeLuna
To approve the consent calendar as presented.
Motion Carried (4 to 0)
5.a APPROVAL OF MINUTES
Motion by: Commissioner Pradetto
Seconded by: Commissioner DeLuna
Approve the Minutes of October 1, 2024.
Motion Carried
5
Planning Commission Special Meeting Minutes
October 29, 2024
2
6. ACTION CALENDAR
This item has been reordered to Public Hearings.
7. PUBLIC HEARINGS
7.a CONSIDERATION TO AMEND SECTION 25.34.030 OF THE MUNICIPAL
CODE REGARDING ACCESSORY DWELLING UNITS AND JUNIOR
ACCESSORY DWELLING UNITS TO COMPLY WITH RECENT CHANGES IN
STATE LAW; AND FINDING THE ACTION TO BE STATUTORILY EXEMPT
FROM CEQA
Planning Technician Aguirre, Principal Planner Flores, and Principal Planner
Melloni narrated a PowerPoint presentation and responded to Commissioner
inquiries.
Chair Gregory opened the public hearing.
With no comments received, Chair Gregory closed the public hearing.
Motion by: Commissioner Pradetto
Seconded by: Commissioner DeLuna
Adopt Planning Commission Resolution No. 2885 entitled: “A RESOLUTION OF
THE PLANNING COMMISSION OF THE CITY OF PALM DESERT,
CALIFORNIA, RECOMMENDING THAT THE CITY COUNCIL ADOPT AN
ORDINANCE AMENDING SECTION 25.34.030 OF THE PALM DESERT
MUNICIPAL CODE RELATING TO ACCESSORY DWELLING UNITS AND
JUNIOR ACCESSORY DWELLING UNITS IN THE CITY, AND FINDING THE
ACTION TO BE STATUTORILY EXEMPT FROM THE CALIFORNIA
ENVIRONMENTAL QUALITY ACT (CEQA) PURSANT TO CALIFORNIA PUBLIC
RESOURCES CODE § 21080.17.”
Motion Carried (4 to 0)
8. INFORMATIONAL REPORTS & COMMENTS
8.a SUMMARY OF CITY COUNCIL ACTIONS
Director of Development Services Cannone provided the Commission updates
on recent approvals made by City Council.
8.b COMMITTEE MEETING UPDATES
8.b.1 Cultural Arts Committee
None.
8.b.2 Parks and Recreation Committee
None.
8.c PLANNING COMMISSIONERS
None.
6
Planning Commission Special Meeting Minutes
October 29, 2024
3
8.d CITY STAFF
Deputy Clerk Nance advised the Commission about AB 1234 Ethics training
taking place January 2025.
8.e ATTENDANCE REPORT
Report provided; no action taken on this item.
9. ADJOURNMENT
The Planning Commission adjourned at 6:45 p.m.
Respectfully submitted,
_________________________
Michelle Nance, Deputy Clerk II
Recording Secretary
_________________________
Richard Cannone, Director of Development Services
Staff Liaison
7
8
Page 1 of 3
CITY OF PALM DESERT
PLANNING COMMISSION
STAFF REPORT
MEETING DATE: November 19, 2024
PREPARED BY: Carlos Flores, AICP, Principal Planner
SUBJECT: CONSIDERATION TO ADOPT A NOTICE OF EXEMPTION AND
APPROVE A CONDITIONAL USE PERMIT AMENDMENT TO ALLOW
THE EXPANSION OF A RESTAURANT AT 77734 COUNTRY CLUB
DRIVE
RECOMMENDATION:
Adopt Planning Commission Resolution No. 2886 entitled, “A RESOLUTION OF THE
PLANNING COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, APPROVING A
CONDITIONAL USE PERMIT AMENDMENT FOR THE EXPANSION OF AN EXISTING
RESTAURANT AT 77734 COUNTRY CLUB DRIVE, SUITE F1, AND ADOPTING A NOTICE
OF EXEMPTION IN ACCORDANCE WITH THE CALIFORNIA ENVIRONMENTAL QUALITY
ACT (CEQA).”
BACKGROUND/ANALYSIS:
On February 16, 2016, the City of Palm Desert Planning Commission (the “Commission”)
adopted Planning Commission Resolution No. 2662 to approve Conditional Use Permit (CUP)
15-382 to allow for a new 1,700 square foot (sf) restau rant, “Alps Village”, located at 77734
Country Club Drive, Suite F. The project was conditionally approved for a restaurant use,
including the sale of food and alcohol, with indoor and outdoor seating within an existing
commercial center. The CUP approved the building for both regular restaurant uses and private
special events.
The project building (“Building”) is a multitenant commercial condominium building located along
Country Club Drive, west of Washington Street, south of Springfield Lane, and east o f Park
Center Drive. The Building is located within a commercial project site that consists of six (6)
separate buildings that were originally constructed under the County of Riverside’s jurisdiction
and incorporated into the City in 1992.
Project Description:
Alps Village (the “Applicant”) has submitted a CUP amendment (CUP24-0004) request to
expand their existing restaurant. Approval of CUP24-0004 would take the existing 1,580 sf
restaurant and allow for an expansion into 77734 Country Club Drive Suites F2 (810 sf) and F3
(730 sf), to make the total square footage of the restaurant 3,120 sf, as shown below in Figure
1 (Assessor’s Parcel Numbers 626-322-008, -009 and -010).
9
City of Palm Desert – Planning Commission
Alps Village Expansion (CUP15-382, Amendment 1)
Page 2 of 3
Figure 1 – Site Plan
Expansion of the restaurant would include demolition of dividing walls to accommodate a larger
kitchen, more indoor seating, and a new private dining area. The project does not propose any
expansion of outdoor seating. Outdoor seating would remain as approved via CUP 15 -382 and
any revisions to expand outdoor seating would require a new CUP amendment application.
Access to the project site is taken off Park Center Drive and Springfield Lane. Parking for the
commercial site was built at three (3) parking spaces per 1,000 square feet and includes shared
parking throughout the site, confirmed by documentation provided by the Applicant. No
additional square footage is being added that would create a potential need for additional
parking.
Table 1 – Adjacent Land Use and Designations
Existing Uses General Plan Zoning
Project Site Existing multitenant
commercial Building
Employment Center PC-2
North Existing multitenant
commercial Building
Employment Center S-I
South Existing residential Golf Course and
Resort Neighborhood
R-1
East Existing multitenant
commercial Building
Employment Center PC-2
West Existing multitenant
commercial Building
Employment Center PC-2
The building meets all Palm Desert Municipal Code standards of the underlying Planned
Commercial – 2 zoning designation and no additions to the building are being considered that
10
City of Palm Desert – Planning Commission
Alps Village Expansion (CUP15-382, Amendment 1)
Page 3 of 3
require additional review. The project, as conditioned, would allow for the c ontinuous operation
of the restaurant to be compatible with surrounding uses.
Expansion of the project includes combination of multiple suites into one larger suite. The suites
are part of a commercial condominium project and expansion will require an instrument recorded
against the property to not allow for individual sale of the suites once they are combined. This
has been placed as a condition of approval under the draft resolution.
Public Input:
Public hearing notices were mailed to all property owners within 300 feet of the proposed project
and published in The Desert Sun on November 8, 2024. To date, the Development Services
Department has received no letters in opposition to or in favor of the proposed project. The
project site HOA has submitted a letter of approval for the project.
Environmental Review:
For the purposes of CEQA, the Director of Development Services has determined that the
proposed project request is categorically exempt under Article 19 Section 15301 – Existing
Facilities (Class 1) of the CEQA Guidelines. The proposed project will involve interior expansion
of an existing restaurant with no physical expansion of the existing building; the project site has
been previously developed and has no value as habitat for endangered, rare or threatened
species; the proposed project does not have a reasonable possibility for significant cumulative
impacts upon the environment; and the site can adequately be served by all required utilities
and public services. Therefore, based on the above findings, staff is recommending that the
Planning Commission adopt a finding that the proposed project is categorically exempt.
Findings of Approval:
Findings can be made in support of the project and in accordance with the City’s Municipal Code.
Findings in support of this project are contained in the draft Planning Commission Resolution No.
2886, attached to this staff report.
Legal Review:
This report was reviewed by the City Attorney’s office.
ATTACHMENTS:
1. Draft Planning Commission Resolution No. 2886
2. Project Plans
3. Public Hearing Notice
11
12
PLANNING COMMISSION RESOLUTION NO. 2886
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
PALM DESERT, CALIFORNIA, APPROVING A CONDITIONAL USE
PERMIT AMENDMENT FOR THE EXPANSION OF AN EXISTING
RESTAURANT AT 77734 COUNTRY CLUB DRIVE, SUITE F1, AND
ADOPTING A NOTICE OF EXEMPTION IN ACCORDANCE WITH THE
CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA).
CASE NO: CUP 15-382, AMD 1 (CUP 24-0004)
WHEREAS, Alps Village (“Applicant”), submitted a Conditional Use Permit (“CUP”)
amendment application to expand an existing restaurant (“Project”) within an existing
building located at 77734 Country Club Drive, Suite F1, to expand to suites F2 and F3 to
accommodate a 3,120 square foot restaurant (Assessor’s Parcel Numbers 626 -322-008,
-009 and -010); and
WHEREAS, the Planning Commission of the City of Palm Desert, California, did
on the 16th day of February 2016, adopt Planning Commission Resolution No. 2662 to
approve Conditional Use Permit 15-382 to allow a new restaurant (“Alps Village”) at
77734 Country Club Drive; and
WHEREAS, under Section 21067 of the Public Resources Code, Section 15367
of the State California Environmental Quality Act (“CEQA”) Guidelines (Cal. Code Regs.,
tit. 14, § 15000 et seq.) and the City of Palm Desert’s (“City’s”) Local CEQA Guidelines,
the City is the Lead Agency for the Project; and
WHEREAS, said application has complied with the requirements of the "City of
Palm Desert Procedure for Implementation of the CEQA” Resolution No. 2024 -35, in that
the Director of Development Services has determined that the Project will not have a
significant impact on the environment and that the Project is categorically exempt under
Article 19, Section 15301 – Existing Facilities (Class 1) of the CEQA Guidelines; and
WHEREAS, the Planning Commission of the City of Palm Desert, California, did
on the 19th day of November 2024, hold a duly noticed public hearing to consider the
request by the Applicant for approval of the above-noted Project; and
WHEREAS, at the said public hearing, upon hearing and considering all testimony
and arguments, if any, of all interested persons desiring to be heard, said Planning
Commission did find the following facts and reasons to exist to justify the approval of said
request:
NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City
of Palm Desert, California, as follows:
13
PLANNING COMMISSION RESOLUTION NO. 2886
2
SECTION 1. Recitals. The Planning Commission hereby finds that the foregoing
recitals are true and correct, and are incorporated herein as substantive findings of this
Resolution.
SECTION 2. Findings on Conditional Use Permit. As required by PDMC Section
25.72.050(F), the Planning Commission makes the following findings to approve CUP 15-
382, AMD 1:
1. That the proposed location of the conditional use is in accordance with the
objectives of the Zoning Ordinance and the purpose of the district in which the site
is located.
Restaurants are permitted subject to a Conditional Use Permit within many zoning
districts within the City. The proposed location is in the Planned Commercial (PC-
2) zone and was previously within the Service Industrial (SI) zone. Professional
offices and mixed commercial, including restaurants, are the predominant uses in
the existing area, and the Project is a continued operation of an existing restaurant.
The proposed location is based on the objectives of the Zoning Ordinance and the
purpose of the district in which the site is located. The services conducted at the
proposed site are compatible with the adjacent business hours and would have
minimal impacts on parking.
2. That the proposed location of the conditional use and the conditions under which
it would be operated or maintained will not be detrimental to the public health,
safety, or welfare, or be materially injurious to properties or improvements in the
vicinity.
The restaurant use complies with all applicable requirements of the Zoning
Ordinance and all applicable building codes and will not be detrimental to general
public health, safety, and welfare or materially injurious to the properties in the
vicinity. Water, sanitation, public utilities, and services are constructed and readily
available for the building.
3. That the proposed conditional use will comply with each of the applicable
provisions of this title, except for approved variances or adjustments.
The Project site is developed, and the proposed use is consistent with the intent
of the underlying zoning designation. The facility would not interfere with business
operations or generate parking deficiencies. Conditions have been placed on the
Project to ensure that all the minimum requirements comply with the Palm Desert
Municipal Code.
4. That the proposed conditional use complies with the goals, objectives, and policies
of the City’s general plan.
14
PLANNING COMMISSION RESOLUTION NO. 2886
3
The proposed restaurant use is the interior expansion of an existing restaurant and
complies with the City’s general plan in providing for a mixture of commercial uses.
The General Plan designation for the project location is “Employment ,” which asks
for a wide variety of commercial uses. The Project complies with General Plan
Policy 3.1: Access to daily activity, by providing a restaurant and Policy 2.3 by
placing conditions to ensure the restaurant is operated in a manageable manner.
NOW, THEREFORE, BE IT RESOLVED BY THE PLANNING COMMISSION OF
THE CITY OF PALM DESERT, CALIFORNIA, AS FOLLOWS:
1. That the above recitations are true and correct and constitute the findings of
the Planning Commission in this case.
2. That the Planning Commission does hereby approve Conditional Use Permit
15-382, AMD 1 / CUP24-0004, subject to the conditions attached hereto
(Exhibit “A”).
SECTION 3. Project Approval. The Planning Commission hereby approves Case
No. CUP24-0004 (CUP 15-382, AMD 1).
SECTION 4. Custodian of Records. The documents and materials that constitute
the record of proceedings on which these findings are based are located at the City’s
office at 73510 Fred Waring Drive, Palm Desert, CA 92260. Richard D. Cannone, AICP,
the Secretary to the Palm Desert Planning Comm ission, is the custodian of the record of
proceedings.
SECTION 5. Execution of Resolution. The Chairperson of the Planning
Commission signs this Resolution, and the Secretary to the Commission shall attest and
certify to the passage and adoption thereof.
ADOPTED ON November 19, 2024.
RON GREGORY
CHAIRPERSON
ATTEST:
RICHARD D. CANNONE, AICP
SECRETARY
15
PLANNING COMMISSION RESOLUTION NO. 2886
4
I, Richard D. Cannone, AICP, Secretary of the City of Palm Desert Planning
Commission, hereby certify that Resolution No. 2886 is a full, true, and correct copy, and
was duly adopted at a regular meeting of the Planning Commission of the City of Palm
Desert on November 19, 2024, by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
RECUSED:
IN WITNESS WHEREOF, I have hereunto set my hand and affixed the official seal of the
City of Palm Desert, California, on November ____, 2024.
RICHARD D. CANNONE, AICP
SECRETARY
16
PLANNING COMMISSION RESOLUTION NO. 2886
5
CONDITIONS OF APPROVAL
CASE NO. CUP 24-0004 (CUP15-382, AMD 1)
Development Services Department:
1. This Conditional Use Permit (“CUP”) approval is to allow the expansion of an existing
restaurant at 77734 Country Club Drive, Suite F1, to expand into Suites F2 and F3 .
The expansion does not include expansion of existing buildings and only includes
expansion into existing suites.
2. This CUP allows for continued operation of the restaurant.
3. This CUP shall lapse and become void one (1) year following the effective date of
the use permit, unless prior to the expiration a bu ilding permit is issued and
construction is commenced and diligently pursued toward completion, or a new
certificate of occupancy is issued for the use, or as specified by Title 25 of the Palm
Desert Municipal Code (“PDMC”). If the CUP expires, the applicant must file a new
application, which shall be processed in accordance with the requirements of Title
25 of the Palm Desert Municipal Code.
4. Prior to the expiration of the permit, the applicant may request a one (1) year time
extension by filing a written request with the Planning Division for consideration by
the Planning Commission. Any request for extension shall be noticed and be
considered at a public hearing held before the original approval body.
5. The Applicant shall comply with all conditions of approval from Planning Commission
Resolution No. 2662.
6. The operation of the facility shall conform substantially to approved exhibits on file
with the Development Services Department, except as modified by conditions herein.
7. Permittee shall notify City Planning Department of any change in operations and
such change may require a revision of this permit. Failure to notify the City of any
change in operations is material grounds for revocation of this CUP.
8. The Project shall be developed and maintained in conformance with the approved
plans and exhibits on file with the City. Any variation from the approved plans must
be reviewed and approved by the Development Services Department prior to
building permit issuance and may require review and approval by the Planning
Commission and/or City Council.
9. The Applicant shall agree to defend, indemnify, and hold harmless the City of Palm
Desert or its agents, officers, and employees from any claim, action or proceeding
against the City of Palm Desert or its agents, officers or employees, to attack, set
aside, void, or annul, any approval of the City of Palm Desert, whether by its City
Council, Planning Commission, or other authorized board or officer of the City. The
17
PLANNING COMMISSION RESOLUTION NO. 2886
6
City of Palm Desert shall promptly notify the applicant of any such claim, action, or
proceeding, and the City of Palm Desert shall cooperate fully in the defense.
10. The operation shall not encroach or obstruct parking lot circulation, access
driveways, ADA paths of travel or emergency vehicle access.
11. Prior to issuance of a building permit for construction of any use or structure
contemplated by this approval, the applicant shall first obtain permits and/or
clearance from the following agencies:
Coachella Valley Water District (CVWD)
Public Works Department
Fire Department
Building & Safety
12. The Applicant shall submit an instrument (deed restriction or unity of title) recorded
against the property that clearly states that Suites F1, F2, and F3 shall not be sold
separately. The document may be removed and suites sold separately only with prior
approval from the City’s Building Official and Director of Development Services, if it
is demonstrated that it meets all requirements of the Subdivision Map Act and
California Building Code.
13. Should parking shortages or other parking-related issues arise, the applicant shall
institute appropriate operational mitigation measures. Proposed mitigation must be
reviewed by the Department of Development Services.
14. No signs are approved by this project. Sign Permit for any exterior signs shall be
submitted to the Planning Division for review and approval prior to installatio n. All
signage must be in accordance with the applicable standards of the Palm Desert
Municipal Code.
15. Changes to the floor plan including, but not limited to, additional seating, shall require
additional review by the Department of Development Services.
16. The applicant or any successor in interest shall comply with all applicable local, state,
and federal laws, rules, ordinances, and regulations.
17. The only outdoor seating approved at this location are the 24 outdoor patio seats
approved via Planning Commission Resolution No. 2662. Any additional outdoor
seating shall be subject to a new CUP amendment application.
END OF CONDITIONS
18
N.T.S
COVER SHEET W/
GENERAL NOTES
C1.0
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
ALPS
VILLAGE
19
20
GALLONS
IN
OUT
SAMPLE
BOX
Raiser
Raiser
Raiser
ON SITE
A 02
1,500
EXISTING
Trash Enclosure Trash Enclosure
Alps Village
2
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
NN EXISTING
Trash Enclosure
EXISTING
Grease
Interceptor
TOTAL 3,230 SF
SITE PLAN IS SHOWN ONLY AS REFERENCE
OVERALL
SITE PLAN
A 1.0
21
(E) STONE COL.
(E) CONC. SIDEWALK
(E) CONC.
SIDEWALK
(E) PLANTER
(E) STONE COL.
(E) PLANTER
(E) STONE COL.
(E) PLANTER
(E) STONE COL.
(E) PLANTER
W/NEW PLANTS
(E) ADA RAMP
(E)PLANTER
(E)PARKING
(E) ADA VAN ACCESSIBLE
PARKING
(E) ADA STRIPING
NO ALCOHOL
(E) STONE COL.
(E) PLANTER
(E) STONE COL.
(E) PLANTER
W/NEW PLANTS
(E) STONE COL.
(E) PLANTER
W/NEW PLANTS
(E)PLANTER
(E) TABLE &
(E) TABLE & SEATING
(E) TABLE & SEATING(E) TABLE & SEATING
(E) WROUGHT IRON
GUARD RAIL
(E) WROUGHT IRON
GUARD RAIL
(E) WROUGHT IRON
GUARD RAIL
(E) WROUGHT IRON
GUARD RAIL
(E
)
P
L
A
N
T
E
R
(E)PLANTER
ELECTRICALPANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
ELECTRICALPANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
ELECTRICALPANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
Trash Enclosure Trash Enclosure
TRASH
SF1,580
Alps Village
GALLONS
IN
OUT
SAMPLE BOX
Raiser
Raiser
Raiser
ON SITE
A 02
1,500
EXISTING
PARKING LOT
EXISTING
PA
R
K
I
N
G
L
O
T
EX
I
S
T
I
N
G
SUITE F1
SF810
SUITE F2
SF730
SUITE F3
EXISTING
RESTAURANT
Health Insurance
Network
1 SITE PLAN
NOTE
1SITE PLAN
NOTE
2
1
1
NON-FIXED
CHAIRS
SEATING
PAST THIS LINE
NON-FIXED
CHAIRS
NO
PARKING
PAVING
CONC. FOOTING
EMBED POST IN
OR SIDEWALK
TOP OF CURB
12"
ON SIGN
OR EQUAL.
WHERE OCCURS
REFLECTORIZED SIGN W/ INTERNATIONAL
SYMBOL OF ACCESSIBILITY. SIGN TO BE
PORCELAIN ON STEEL W/ BEADED TEXT
PROVIDE AT VAN
PAINTED SYMBOL
ACCESSIBLE SPACE
BO
T
T
O
M
O
F
L
O
W
E
S
T
S
I
G
N
86
"
M
I
N
.
80
"
M
I
N
.
PAINTED SYMBOL @ PARKING STALL,
WHITE (SEE SITE PLAN FOR LOC.)
$ 250.00
’
11B-502.8.2
MINIMUM FINE
NOTE : PER CBC 11B-502.6
2" GALV. STEEL
PUNCHED POST
SQUARE PRE-
A
B ONLY
11B-705.1 Detectable warnings
1 .
2 .
3 .
4 .
5 .
6 .
11B- 402 accessible Route
11B-705.1.1.3 Color and Contrast
11B-705.1. Detectable Warnings
11B-705.1.1.2 Dome Spacing
11B- 405 Ramps .
11B- 405.1 General
11B- 405.2 Slopes
11B- 405.3 Cross Slopes
11B- 405.5 Clear Width
11B- 405.6 Rise
EXCEPTION 2 :
11B- 405.7 Landing
11B-405.7.1 Slope
11B-405.7.2 Width
11B-405.7.2.1
11B-405.7.3 Length
11B-405.7.3.1
11B-405.7.4 Change in Direction
11B-405.7.5 Doorways
11B-405.7.5 Handrails
11B- 705.1.1.3 Detectable Warning Surfaces
CBC
33538 SAE AMS-STD - 595A
11B- 705.1.1.3.1 Detectable Warning Surfaces
11B- 705.1.1.4 Detectable Warning Surfaces
11B- 402 accessible Route
PATH OF TRAVEL
PUBLIC ACCESSIBLE
1 SITE PLAN NOTE
A
B
C
Delineated " Path of Travel " shownig access from public side to Building
entrance and exit with accessibility sign per. 2022 California State Building.
Accessible parking sign per. sec of California State Building Code.
No abrupt changes in elevation along " Path of Travel " shown.
Site notes :
DISABLED ACCESSIBLE PARKING SPACES SHALL CONFORM TO THE
FOLLOWING :
1. - 9'-0" x 19'-0" space with a striped 5'-0" wide loading and unloading area
on the passenger side ( double handicapped spaces may utilize the same
5'- 0" stripped area ) Not less than one van accessible space shall be
provided with a 12 '-0" access aisle located on passenger side.
2. - 1 Unit vertical to 50 units horizontal in any direction.
3. - All handicap spaces shall be identified with the international symbol
Forward Sidewalk shall not exceed 5%
Cross slope shall not exeed 2 %
Slope ramp shall not exeed 8.33 % slope.
1
2
3
K
E
Y
N
O
T
E
S
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
Scale :
Section Elevation
NOT TO SCALE
ACCESSIBLE DETAILS & NOTES
EXISTING
Grease Inteceptor
EXISTINGEXISTING
SIGN IDENTIFYING ACCESIBLE ENTRANCE
PLACED IN EASILY VISIBLE LOCATION
IDENTICAL SIGNS TO BE PLACED ALONG
ACCESIBLE ROUTE
EXISTING
EXISTING
EXISTING
BACK FLOW DEVICE
EXITING SITE PLAN1
CITY OF PALM DESERT CA.
NN
Alps Village
SITE PLAN
& ADA
DETAILS
A 1.1
22
NOTE A
A2 B
EXISTING
STUD DESCRIPTION
1 Hour Demising WallDetail
WALL TYPE SPACING
SIZE
MATERIAL
TYPE
21
2 X 6
WOOD
D.F.
16"
O. C.
5/8" GYP. BD.
PROVIDE MIN
INSULATION
INTERIORINTERIOR
5/8" GYP. BD.
( WHEN NOT EXISTING )
STRUCTURAL FRAMING
EXISTNG
R 11
FLOORING WINDOWS & EXTERIOR DOORS
10
21
22
Tr
a
s
h
E
n
c
l
o
s
u
r
e
Tr
a
s
h
E
n
c
l
o
s
u
r
e
TR
A
S
H
F F
F
F
F
F
FFFFFF
0
00
20
01
Existing Floor Plan Key Notes
02
00
03
04
05
04
WALLS
20
21
A
00
00
00 00
00
00
00
20
10 10 10 10 10 10
10
10
10
21
A
20
21
A
21
A
21
A
20
20
25
26
24
21
A
24 24
26
23
22
22
05
05
03
03
05
03
25
23
26
2424 22
22
22
02
02
01
01
01
22
22
22
22
220103
D.0
D.0
D.2D.1
D.3
D.3
D.4
D.3 R
D.4 R
DEMOLITION
27
D.5
A THIS PAGE ( EXTREME RIGHT )
D.2 C
23
23 27
2323
24
23
23 ADJACENT SUITE F3
BEING OCCUPIED
ADJACENT SUITE F2
BEING OCCUPIED
EXISTING OCCUPLED SUITE F1
AS RESTAURANT & BAR
730 SQ. FT.810 SQ. FT.1,580 SQ. FT.
" Alps Village "
Existing Building Conditions & Demolition Plan1
EXISTING BUILDING
CONDITIONS &
DEMOLITION
A 2.0
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
23
0
72"
D A 3.4
DOORS
1
36"
D A 3.4
4
36"
D A 3.4
3
36"
D A 3.4
2
36"
D A 3.4
05
36"
D A 3.4
36"
D.4 R
D.4
D.3
D.2
D.1
D.0
D.3 R
3
36"
D A 3.4
D.5
05
36"
D A 3.4
D.5
2
36"
D A 3.4
D.2 R
60
"
X
1
8
"
60
"
X
1
8
"
36
"
X
1
8
"
36"X18"
48"X18"
48"X18"
FLOORING WINDOWS & EXTERIOR DOORS
10
21
22
0
00
20
01
Existing Floor Plan Key Notes
02
00
03
04
05
04
WALLS
20
21
A
00
00
00 00
00
00
00
20
10 10 10 10 10 10
10
10
10
21
A
20
21
A
21
A
21
A
20
20
25
26
24
21
A
24 24
26
23
22
22
05
05
03
03
05
03
25
23
26
2424 22
22
22
02
02
01
01
01
22
22
22
22
220103
D.0
D.0
D.2D.1
D.3
D.3
D.4
D.3 R
D.4 R
DEMOLITION
27
D.5
A THIS PAGE ( EXTREME RIGHT )
ADJACENT SUITE F3
BEING OCCUPIED
ADJACENT SUITE F2
BEING OCCUPIED
D.2 C
23
23 27
23
Tr
a
s
h
E
n
c
l
o
s
u
r
e
Tr
a
s
h
E
n
c
l
o
s
u
r
e
TR
A
S
H
F F
F
F
F
F
FFFFFF
23
24
23
23 EXISTING OCCUPLED SUITE F1
AS RESTAURANT & BAR
730 SQ. FT.810 SQ. FT.1,580 SQ. FT.
1
1
" Alps Village "
Existing Building Conditions / Existing Restaurant1
EXISTING BUILDING
CONDITIONS &
( E ) RESTAURANT
A 2.1
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
24
WALLS
A SHEET A 2.1
20
21
22
NEW WALLS
A
1
3
4
5
2
20
21
A
20
21
A
20
21
A
21
A
21
A
20
20
21
A
22
22
22
22
22
22
22
22
22
FILL-IN
D.0
D.0
D.2D.1
D.3
D.3
D.4
D.3 R
1W
1W 2W
1W
2W
D.5
DOUBLE
SWING
DOUBLE
SWING
3W
3W 3W
3W
F
23 23
4W
D.5
F
A 2.6 F
A 2.6 F
A 2.6
A
A 2.6
A
A 2.6
B
A 2.6
4W
B
" Alps Village "
Dimension Plan1
EXISTING BUILDING
CONDITIONS &
DEMOLITION
A 2.2
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
25
WOOD FRAME
DETAILS &
NOTES
A2.6
26
Business Group B
Egress Path of Travel Employee's
Egress Path of Travel Customers
EMERGENCY EXIT ROUTE
L E G E N D
Fire Note :
11B-305.5
11B-305.6
11B-305.7
11B-305.7.1
11B-902.3 Height
51 - 150 3
Minimum number of required From 2022 California Buiding Code .
Number of Seats
Wheelchair spaces . ( Table 11B - 221.2.1.1 )
WHEELCHAIR SPACES IN ASSEMBLY AREAS
Wheelchairs Required
4 - 25 1
26 - 50 2
FIGURE 11B-404.2.4.1
2022 CALIFORNIA BUILDING CODE:
11B-404-2.4.1
TYPE OF USE MINIMUM MANEUVERING CLEARANCE
Seating Calculations ( Real Countable Seats )
40
ADA
138
8
Note
Seating Spaces
.
Seats
T O T A L
138
NOTE :
CAPACITY WIDTH CALCULATIONS
""149 29.8 360.2 INCH
The capacity, in inches, of means of egress components other
than stairways shall be calculated by multiplying the occupant
load served by such component by a means of egress
capacity factor of 0.2 inch (5.1 mm) per occupant.
1005.3.2 Other egress components.
SECTION 1005
MEANS OF EGRESS SIZING
A.03
MO
P
S
I
N
K
75
"
3
D
r
.
R
e
a
c
h
i
n
C
o
o
l
e
r
/
F
r
e
e
z
e
r
2
0
1
4
B
&
B
SODA
1 2 3 4 5 6
DISPENSER
BBAA
75
I
N
RE
A
C
H
I
N
C
O
O
L
E
R
DOUBLE
SWING
DOUBLESWING
CH
A
I
R
&
T
A
B
L
E
S
48
"
H
o
t
F
o
o
d
T
a
b
l
e
RE
F
P
R
E
P
T
A
B
L
E
6
0
ELECTRICALPANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
ELECTRICALPANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
Tr
a
s
h
E
n
c
l
o
s
u
r
e
Tr
a
s
h
E
n
c
l
o
s
u
r
e
F F
F
F
F
F
FFFFFF
A
C B
C B
CB
SF52
SF324
SF252
SF44 SF58 SF110
SF1,180
SF46
SF72
SF128
SF684
SF170
D
T
RR
P
K
E
J
H
C
B
A
G
M
P
P
P
A
AA
A
A
G
KM
N
H 2
R
48
50
1
1
" Alps Village "
Schematic Occupancy Areas1
" Alps Village "
Egress Plan1
SCHEMATIC
OCCUPANCY &
LOAD CALCULATIONS
A 3.0
Occupant Load Shall comply with current codes CBC T-1004.1.1
Occupant Load Calculation Table
Designated Area
From 2022 CBC
Square Ft.Factor Occupant Load*
OCUPANCY GROUP CATEGORY :
Section
A-2
304 Foodservice
TOTAL
OCCUPANCY LOAD
TOTAL
SQUARE FOOTAGE =
Egress Code
=3,120 93
=/Gross 168 0N/ARestroom
=/Gross 1,180 6200Kitchen Area
=/Gross 342 0N/AHallway
=/Gross 170 1200Bar Area
( CBC 1004.6 . Fixed Seating )
* Net =252 35 420
24 18
FIXED DINING 3
INDOORS
Total Occupancy Load 146
SQ.FT3,120TOTAL AREA
SQ.FTADINING AREA 684
SQ.FTBSERVICE BAR AREA 170
SQ.FTHHALLWAY(S) AREA 44+52+46+128+72342
SQ.FTRRESTROOM AREA 110 + 58 168
Occupancy calc's
SQ.FTKKITCHEN AREA 1,180
SQ.FTMDINING AREA 2 324
SQ.FTNDINING AREA 3 252
( CBC 1004.6 . Fixed Seating )
* Net =NA 108.5 1,302
24 53
FIXED DINING 4
=/Gross 324 2215
DINING 2
=/Gross 684 4615
DINING 1
P PATIO AREA LINEAR FT =112.5
303.3 Assembly Group A-2.
USE AND OCCUPANCY CLASSIFICATION
CHAPTER 3
A2 SECTION 303 Assembly Group " A "
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
2
27
A.03
MO
P
S
I
N
K
75
"
3
D
r
.
R
e
a
c
h
i
n
C
o
o
l
e
r
/
F
r
e
e
z
e
r
2
0
1
4
B
&
B
SODA
1 2 3 4 5 6
DISPENSER
BBAA
75
I
N
RE
A
C
H
I
N
C
O
O
L
E
R
DOUBLE
SWING
DOUBLESWING
D.0
D.0
D.2D.1
D.3
D.3
D.4
D.3 R
D.5
D.5
CH
A
I
R
&
T
A
B
L
E
S
48
"
H
o
t
F
o
o
d
T
a
b
l
e
RE
F
P
R
E
P
T
A
B
L
E
6
0
EXIT
EXIT
EXIT
EX
I
T
1
40
A
F
F
F
1
11
ELECTRICALPANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
ELECTRICALPANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
D
T
RR
P
K
E
J
H
C
B
A
G
M
P
P
P
A
AA
A
A
G
KM
N
H 2
R
EM
E
R
G
E
N
C
Y
L
I
G
H
T
EMERGENCY LIGHT
2
2
2
2
2
2
5
6
6
2
2
2
2
2
2
2 2
Tr
a
s
h
E
n
c
l
o
s
u
r
e
Tr
a
s
h
E
n
c
l
o
s
u
r
e
F F
F
F
F
F
FFFFFF
A
C B
C B
CB
2
OCCUPANCY
LOAD
149
Seats20
Seats22
Seats36
Seats22
Seats8
Seats12
F
I
R
E
P
L
A
C
E
1
1
F4
A1NOTE
A2NOTE
A3NOTE
A7NOTE
A9NOTE
Notes:
CBC 101.3.4 & 11B - 703.
SAN SHERIF
Tactile Exit Signage
FIGURE F 0
ENTER
PROPOSED TACTILE EXIT SIGNAGE
PER CBC 2022
SIGN SHALL BE LOCATED TO THE LATCH
SIDE OF THE SINGLE DOOR & TO THE RIGHT
SIDE FO DOUBLE DOOR 58" - 60" A.F.F.
EXIT
PROPOSED TACTILE ENTER SIGNAGE
PER CBC 2022
SIGN SHALL BE LOCATED TO THE LATCH
SIDE OF THE SINGLE DOOR & TO THE RIGHT
SIDE FO DOUBLE DOOR 58" - 60" A.F.F.
FIGURE F 1
" Alps Village "
Fire Requirements Floor Plan1
11B-305.5
11B-305.6
11B-305.7
11B-305.7.1
11B-902.3 Height
FLOOR PLAN
FIRE & SAFETY
REQUIREMENTS
A 3.1
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
1004.3 POSTING OF OCCUPANT LOAD.1F
Fire Requirements
2F
3F
6F
6"
6"
7FENTER
F.0
A 3.1
EXIT
F.1
A 3.1
EXIT ROUTE
" DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED "
8F
10F
D E T A I L
ANSUL SUPPRESSION SYSTEM
0F
HANDICAPPED
RESERVED
40
F
12F 12CEMENT
5 FEET
FIRE EXTINGUISHERS INFORMATION
A
5F
9F
EXIT
" DIRECTIONAL SIGNAGE "
EMERGENCY LIGHT
EMERGENCY LIGHT
PS
PS
WITH LED EMERGENCY LIGHTING
HEADS
&90 MIN. BATTERY BACK UP
EXIT SIGN
LED EMERGENCY LIGHTING
&90 MIN. BATTERY BACK UP
BUG EYE
FIRE EXTINGUISHERS NOTES
4F
B
EXTERIOR DOORS
SWING OUTWARDS
Fire Note :
KNOX BOX NOTE :
28
11B-308.2.2 OBSTRUCTED HIGH REACH.
11B-404.2.5
11B-404.2.7
11B-404.2.9
11B-404.2.10
DOORS NOTES :
11B-404.2.3
CLEAR
11B-226.1
ACCESSIBILITY NOTE:
NOTE A :
NOTE B :
F1. FIRE DEPARTMENT GENERAL NOTES ON PLANS PER 2022 CALIFORNIA FIRE CODE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
11B-309.4 OPERATION.
ACCESSIBILITY NOTES :FIRE DEPARTMENT NOTES
.
.
FIRE DEPARTMENT NOTES
CBC 703.7:FIRE NOTE .
A.
B.
A.
" FIRE AND /OR SMOKE BARRIER - PROTECT ALL OPENINGS "
11B-226.1 General
Exceptions .
11B-226 Dining Surfaces & Work Sufaces
11B-226.3 Dining Surfaces Exceeding 34 Inches in Height
11B-226.4 Baby Diaper Changing Station
11B-902.3 Height
FIRE & SAFETY
REQUIREMENTS
& NOTES
A 3.2
Section View
Note
Seating Spaces
.
THRESHOLD @ TILE
( Where applicable )
Section View
Scale
Human
BUILT-IN LOWERED COUNTERTOP ( 32" - 34" )
Section View
NOTE :
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
29
ENTRANCE SIGNS: CBC 2022
SIGNS & IDENTIFICATION
10"
7'
-
0
"
3'-0"
34
"
3'-0"
11B-703.7.2.6.3
SCALE QTY.
6'
-
8
"
SCALE QTY.
UNISEX
SYMBOL DESCRIPTION
’
’
’
’
SCALE QTY.
E X I S T I N G
34
"
10"
7'
-
0
"
3'-0"
FIGURE A1
ALL GENDER / UNISEX
See Hardware Notes :XD3E/R 3'-0"6'-8"3 --LAMINATED ..LAMINATED .2...
10"
3'-0"
6'
-
8
"
34
"
SCALE QTY.
E X I S T I N G
E X I S T I N G
10"
3'-0"
6'
-
8
"
34
"
E X I S T I N G
See Hardware Notes :XD5E/N 4'-0"6'-8"2 --ALUMINUM ..ALUMINUM .8...
See Hardware Notes :XD2E3'-0"7'-0"1 --GLASS ..ALUMINUM . 2 & 3...
SCALE QTY.
See Hardware Notes :XD1E3'-0"7'-0"1 --GLASS ..ALUMINUM .1, 2 & 3...
SCALE QTY.
34
"
10"
7'
-
0
"
3'-0"
E X I S T I N G
SCALE
Door Frame Typical A1
NTS Refer To Door Schedule
See Contractor's Notes
38. THRESHOLDS, IF PROVIDED AT DOORWAYS, SHALL BE ½ INCH HIGH MAXIMUM. RAISED
THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH 11B-302 FLOOR OR
GROUND SURFACES AND 11B-303 CHANGES IN LEVEL. §11B-404.2.5.
39. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES
SHALL COMPLY WITH 11B-309.4
OPERATION. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34
INCHES MINIMUM AND 44 INCHES MAXIMUM ABOVE THE
FINISH FLOOR OR GROUND. WHERE SLIDING DOORS ARE IN THE
FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE
EXPOSED AND USABLE FROM BOTH SIDES. §11B-404.2.7
40. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE
OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: §11B-404.2.9
A. INTERIOR HINGED DOORS AND GATES: 5 POUNDS MAXIMUM.
B. SLIDING OR FOLDING DOORS: 5 POUNDS MAXIMUM.
C. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE
ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY,
NOT TO EXCEED 15 POUNDS.
D. EXTERIOR HINGED DOORS: 5 POUNDS MAXIMUM.
41. SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF
THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON
THE PUSH SIDE EXTENDING THE FULL
WIDTH OF THE DOOR OR GATE. PARTS CREATING HORIZONTAL OR
VERTICAL JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16 INCH
OF THE SAME PLANE AS THE OTHER AND BE FREE OF SHARP OR
ABRASIVE EDGES. CAVITIES CREATED BY ADDED KICK PLATES
SHALL BE CAPPED. §11B-404.2.10
CALIFORNIA BUILDING CODE
2022
A
B
C
D
E
PANIC HARDWARE NOTES
DOOR'S NOTE *
A
CODE QTY THICK TYPE MAT'L FIN.TYPE MAT'L FIN.
DOOR FRAME HDWR.
SET
HEAD.
DETL.
JAMB
DETL.LABEL REMARKS
DOOR SCHEDULE
&SIZE
E NERR
See Hardware Notes :XD4E3'-0"6'-8"2 --LAMINATED ..LAMINATED .3...
See Hardware Notes :XD0E6'-0"7'-0"2 --GLASS ..ALUMINUM . 1, 2 , 3 & 4...
THIS DOOR SHALL BE INSTALLED WITH A PUSHING OPENABLE MECHANISM ( PANIC HARDWARE )
G E N E R A L
ACCESSIBILITY DOORS HARDWARE NOTES & REQUIREMENTS :Notes:B
B* .F4
2
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
DOOR SCHEDULE
& DETAILS
A 3.4
30
4'-0"
60
IN C H ES H A N D I CCAPED
DI
A
M
E
T
E
R
ADA
OPERABLE PARTS
DIVISION 6
PLUMBING ELEMENTS & FACILITIES
Mirror
CL
Figure 11B-603.3
a
- -
a
- -
Figure 11B-306.2CFigure 11B-604.8.1.1.2A
Figure 11B-604.8.1.1.21
B
Figure 11B-605.2D Figure 11B-605.2
a
- -
Figure 11B-604.8.1.4
ACCESSIBLE LAVATORY
REDUCTION THEREFORE IS 3"
3"
REDUCTION THEREFORE IS 3"
3"
GRAB BAR MOUNTING
( Where applicable )
Accessible restrooms NOTES :
f.
h.
i.
Hand Washing Sink
Hand Washing Sink / Lavatory
a.
b.
c.
d.
11B-604.4 & 11B-609 :
Urinals11B-605 :
Lavatories11B-606 :
Grab Bars
CBC 11B-604.9.6Dispensers.
SINGLE ACCOMODATION TOILET FACILITY
__2022 CALIFORNIA BUILDING CODE
CL
CL
30 " X 48 "
60 " X 48 "
TYPICAL
" Alps Village "
Enlarged Restroom1
ENLARGED
ESTROOMS
& DETAILS
A 3.5
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
31
CEILING PLAN
A4
+8'-0" HARD LID
EXIT
+8'-0" HARD LID
(E)
(E)
(E)(E)
(E)(E)
(E)(E)(E)
(E)
(E)
(E)(E)
(E)
(E)(E)
J
J J
J J
J J
(E)(E)
(E)
(E)
+9'-6"
PATIO HEIGHT
+9'-6"
PATIO HEIGHT
+9'-6"
PATIO HEIGHT
EX
I
T
EXIT
(E)
EXIT(E)
EX
I
T
(E)
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
+8'-0" HARD LID
(E)
(E)
(E)
(E)
(E)(E)
(E)
(E)
J
EXIT
EXIT
S
+11'-0" AFF
+11'-0" AFF
+11'-0" AFF
+11'-0" AFF
+11'-0" AFF
+12'-0"
CEILING
HEIGHT
+12'-0"
CEILING
HEIGHT
+12'-0"
CEILING
HEIGHT
+12'-0"
CEILING
HEIGHT
+8'-0"
CLNG
32
ROOF PLAN
A5
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
PLATFORM MECHANICAL EQUIPMENT
BRACKET DETAIL
NOTES :
01
01
33
MAX
24"MIN.
54" MIN.
12"
17
"
-
1
8
"
56" MIN
60
"
MI
N
.
12
"
MI
N
.
24
"
MI
N
.
CL
36" GRAB BAR BOBRICK
B-5806 X 36
ADA WATER CLOSET
42" GRAB BAR
BOBRICK B6202-1
SEAT COVER DISPENSER
BOBRICK B-221
ADA LAVATORY
18
"
MI
N
.
ADA
48"X30"
+8'-0"
+0'-0"
6"MAX
TOE CLR.
8"MIN.
KN EE CLR.
9"
M
I
N
17"MIN
LAV. DEPTH.
27
"
M
I
N
+4'-0"
(N)FRP BOARD
(N)BOBRICK B-262
PAPER/TOWEL
DISPENSER
(N)ADA LAVATORY
&FAUCET
(N) 6" QUARRY TILE
W/3/8" COVE BASE
+8'-0"
+0'-0"
+4'-0"
(N)FRP BOARD
NEW ADA
WATER CLOSET
33
"
-
3
6
"
17
"
-
1
9
"
19
"
7"-9"
+8'-0"
+0'-0"
+4'-0"
(N)FRP BOARD 42" GRAB BAR
NEW TOILET
PAPER DISPENSER
BY BOBRICK B-264
0'-0"F.F.
34
"
M
A
X
40
"
M
A
X
29
"
M
I
N
+8'-0"
NEW ADA
WATER CLOSET
33
"
-
3
6
"
17"-18"
+4'-0"
(N)FRP BOARD
NEW 24"X36"
MIRROR BY BOBRICK
B-166 2436
NEW ADA
LAVATORY
NEW SOAP DISPENSER
BY BOBRICK B-2112
NEW BOBRICK
B-5806 X 36
36" GRAB BAR
18" MIN.
12"
MIN.
24"
MIN.
36" MIN.
CL
48" MIN
29
"
M
I
N
34
"
M
A
X
40
"
M
A
X
(N) 6" QUARRY TILE
W/3/8" COVE BASE
(N) 6" QUARRY TILE
W/3/8" COVE BASE
(N) 6" QUARRY TILE
W/3/8" COVE BASE
40
"
M
A
X
40
"
M
A
X
RESTROOM
SUIT F-1
PLAN VIEW
RESTROOM
SUIT F-1
EAST VIEW
RESTROOM
SUIT F-1
NORTH VIEW
RESTROOM
SUIT F-1
WEST VIEW
RESTROOM
SUITE F-1
SOUTH VIEW
PAINT GLOSS OR
SEMI-GLOSS
PAINT GLOSS OR
SEMI-GLOSS
PAINT GLOSS OR
SEMI-GLOSS
A6
RESTROOM
INTERIOR
ELEVATIONS
SUITE F1
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
NOTE
-RESTROOM FLOORS SHALL HAVE
A SMOOTH HARD &
NON-ABSORBENT & SLIP
RESISTANT SURFACE SUCH AS
TILE OR OTHER APPROVED
MATERIALS & EXTENDS 4" ONTO
THE WALLS.
-FAUCET CONTROLS AND
OPERATING MECHANISMS SHALL
BE OPERABLE WITH ONE HAND AND
SHALL NOT REQUIRE TIGHT
GRASPING PINCHING OR TWISTING
OF WRIST. SHOW THE FORCE
REQUIRED TO ACTIVATE
CONTROLS SHALL BE NOT
GREATER THAN 5 LBS.
(CBC 11B-309)
SCALE 1/2" 1'-0"
34
MAX
24"MIN.
54" MIN.
12"
17
"
-
1
8
"
56" MIN
60
"
MI
N
.
12
"
MI
N
.
24
"
MI
N
.
CL
36" GRAB BAR BOBRICK
B-5806 X 36
ADA WATER CLOSET
42" GRAB BAR
BOBRICK B6202-1
SEAT COVER DISPENSER
BOBRICK B-221
ADA LAVATORY
18
"
MI
N
.
AD
A
30
"
X
4
8
"
RESTROOM
SUIT F-2
PLAN VIEW
+8'-0"
+0'-0"
6"MAX
TOE CLR.
8"MIN.
KN EE CLR.
9"
M
I
N
17"MIN
LAV. DEPTH.
27
"
M
I
N
+4'-0"
(N)FRP BOARD
(N)BOBRICK B-262
PAPER/TOWEL
DISPENSER
(N)ADA LAVATORY
&FAUCET
(N) 6" QUARRY TILE
W/3/8" COVE BASE
+8'-0"
+0'-0"
+4'-0"
(N)FRP BOARD
NEW ADA
WATER CLOSET
33
"
-
3
6
"
17
"
-
1
9
"
19
"
7"-9"
+8'-0"
+0'-0"
+4'-0"
(N)FRP BOARD 42" GRAB BAR
NEW TOILET
PAPER DISPENSER
BY BOBRICK B-264
0'-0"F.F.
34
"
M
A
X
40
"
M
A
X
29
"
M
I
N
+8'-0"
NEW ADA
WATER CLOSET
33
"
-
3
6
"
17"-18"
+4'-0"
(N)FRP BOARD
NEW 24"X36"
MIRROR BY BOBRICK
B-166 2436
NEW ADA
LAVATORY
NEW SOAP DISPENSER
BY BOBRICK B-2112
NEW BOBRICK
B-5806 X 36
36" GRAB BAR
18" MIN.
12"
MIN.
24"
MIN.
36" MIN.
CL
48" MIN
29
"
M
I
N
34
"
M
A
X
40
"
M
A
X
(N) 6" QUARRY TILE
W/3/8" COVE BASE
(N) 6" QUARRY TILE
W/3/8" COVE BASE
(N) 6" QUARRY TILE
W/3/8" COVE BASE
PAINT GLOSS OR
SEMI-GLOSS
40
"
M
A
X
40
"
M
A
X
RESTROOM
SUIT F-2
EAST VIEW
RESTROOM
SUIT F-2
SOUTH VIEW
RESTROOM
SUIT F-2
WEST VIEW
RESTROOM
SUIT F-2
NORTH VIEW
PAINT GLOSS OR
SEMI-GLOSS
PAINT GLOSS OR
SEMI-GLOSS
PAINT GLOSS OR
SEMI-GLOSS
A6.1
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
SCALE 1/2" 1'-0"
NOTE
-RESTROOM FLOORS SHALL HAVE
A SMOOTH HARD &
NON-ABSORBENT & SLIP
RESISTANT SURFACE SUCH AS
TILE OR OTHER APPROVED
MATERIALS & EXTENDS 4" ONTO
THE WALLS.
-FAUCET CONTROLS AND
OPERATING MECHANISMS SHALL
BE OPERABLE WITH ONE HAND AND
SHALL NOT REQUIRE TIGHT
GRASPING PINCHING OR TWISTING
OF WRIST. SHOW THE FORCE
REQUIRED TO ACTIVATE
CONTROLS SHALL BE NOT
GREATER THAN 5 LBS.
(CBC 11B-309)
RESTROOM
INTERIOR
ELEVATIONS
SUITE F2
35
MAX
24"MIN.
54" MIN.
12"
17
"
-
1
8
"
56" MIN
60
"
MI
N
.
12
"
MI
N
.
24
"
MI
N
.
CL
36" GRAB BAR BOBRICK
B-5806 X 36
ADA WATER CLOSET
42" GRAB BAR
BOBRICK B6202-1
SEAT COVER DISPENSER
BOBRICK B-221
ADA LAVATORY
18
"
MI
N
.
ADA
48"X30"
+8'-0"
+0'-0"
6"MAX
TOE CLR.
8"MIN.
KN EE CLR.
9"
M
I
N
17"MIN
LAV. DEPTH.
27
"
M
I
N
+4'-0"
(N)FRP BOARD
(N)BOBRICK B-262
PAPER/TOWEL
DISPENSER
(N)ADA LAVATORY
&FAUCET
(N) 6" QUARRY TILE
W/3/8" COVE BASE
+8'-0"
+0'-0"
+4'-0"
(N)FRP BOARD
NEW ADA
WATER CLOSET
33
"
-
3
6
"
17
"
-
1
9
"
19
"
7"-9"
+8'-0"
+0'-0"
+4'-0"
(N)FRP BOARD 42" GRAB BAR
NEW TOILET
PAPER DISPENSER
BY BOBRICK B-264
0'-0"F.F.
34
"
M
A
X
40
"
M
A
X
29
"
M
I
N
+8'-0"
NEW ADA
WATER CLOSET
33
"
-
3
6
"
17"-18"
+4'-0"
(N)FRP BOARD
NEW 24"X36"
MIRROR BY BOBRICK
B-166 2436
NEW ADA
LAVATORY
NEW SOAP DISPENSER
BY BOBRICK B-2112
NEW BOBRICK
B-5806 X 36
36" GRAB BAR
18" MIN.
12"
MIN.
24"
MIN.
36" MIN.
CL
48" MIN
29
"
M
I
N
34
"
M
A
X
40
"
M
A
X
(N) 6" QUARRY TILE
W/3/8" COVE BASE
(N) 6" QUARRY TILE
W/3/8" COVE BASE
(N) 6" QUARRY TILE
W/3/8" COVE BASE
40
"
M
A
X
40
"
M
A
X
ADA
48"X48"
RESTROOM
SUIT F-3
PLAN VIEW
RESTROOM
SUIT F-3
EAST VIEW
RESTROOM
SUIT F-3
SOUTH VIEW
RESTROOM
SUIT F-3
WEST VIEW
RESTROOM
SUITE F-3
NORTH VIEW
PAINT GLOSS OR
SEMI-GLOSS
PAINT GLOSS OR
SEMI-GLOSS
PAINT GLOSS OR
SEMI-GLOSS
A6.2
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
NOTE
-RESTROOM FLOORS SHALL HAVE
A SMOOTH HARD &
NON-ABSORBENT & SLIP
RESISTANT SURFACE SUCH AS
TILE OR OTHER APPROVED
MATERIALS & EXTENDS 4" ONTO
THE WALLS.
-FAUCET CONTROLS AND
OPERATING MECHANISMS SHALL
BE OPERABLE WITH ONE HAND AND
SHALL NOT REQUIRE TIGHT
GRASPING PINCHING OR TWISTING
OF WRIST. SHOW THE FORCE
REQUIRED TO ACTIVATE
CONTROLS SHALL BE NOT
GREATER THAN 5 LBS.
(CBC 11B-309)
SCALE 1/2" 1'-0"
RESTROOM
INTERIOR
ELEVATIONS
SUITE F3
36
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
JUNE 2023
DRN. BY
R.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: TENANT IMPROVEMENT
ALPS VILLAGE
PALM DESERT, CA 92211
77734 COUNTRY CLUB DR,
INDOOR LIGHTING
TITLE
24
T24
SUITES F-1, F-2, F-3
37
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
JUNE 2023
DRN. BY
R.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: TENANT IMPROVEMENT
ALPS VILLAGE
PALM DESERT, CA 92211
77734 COUNTRY CLUB DR,
DOMESTIC HOT
WATER
TITLE
24
T24.1
SUITES F-1, F-2, F-3
38
J
75
"
3
D
r
.
R
e
a
c
h
i
n
C
o
o
l
e
r
/
F
r
e
e
z
e
r
2
0
1
4
SODA
1 2 3 4 5 6
DISPENSER
J
)
J
)
J
J
J
(:$//02817('
7$1./(66:$7(5
+($7(56
)J
)
)
J
)
)
J J
J
J
)
)
$))
$))
)
$))
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
)
JUQG
&2
79
5(&(37$&/(
$
)
)
$
)
)
$
)
)
$
)
)
)
JUQG
&2
JUQG
&2
JUQG
&2
JUQG
&2
JUQG
&2
)
JUQG
&2
)
JUQG
&2
)
JUQG
&2
&21'(16(5
$7522)
&21'(16(5
$7522)
)
JUQG
&2
)
(;,67,1*$03
3$1(/%2$5'
)
3+$6(:,5(
&,5&8,7
(;,67,1*$03
3$1(/%2$5'
)
3+$6(:,5(
&,5&8,7
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
EXIT
EXIT
ELECTRICAL
POWER PLAN,
PANEL SCHEDULES
& NOTES
E1
39
NOTE;
LIGHTS AT CUSTOMER/DINING
AREA TO BE CONNECTED TO AN
ASTRONOMICAL TIME CLOCK
FOR AUTOMATIC SHUT-OFF
NOTE ALL LUMINARIES SHALL BE LISTED IN ACCORDANCE WITH 410.6
1. ALL SENSOR LOCATIONS ARE APPROXIMATE. REFER TO
MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO
INSTALLATION.
2. ULTRASONIC CEILING MOUNT SENSORS SHOULD BE
LOCATED A MINIMUM OF FOUR (4) FEET FROM HVAC
SUPPLY/RETURN VENTS.
3. THROUGH MOUNTED, PENDANT MOUNTED AND PENDANT
MOUNTED INDIRECT LIGHTING SOURCES AFFECT THE
OPERATION OF LOCALLY MOUNTED SENSORS.
CONTRACTOR IS RESPONSIBLE FOR ADJUSTING SENSOR
LOCATIONS TO ALLOW FOR PROPER OPERATION.
4. LIGHTING CONTRACTOR IS RESPONSIBLE FOR PROPER
SENSITIVITY AND TIME DELAY SETTINGS FOR
NON-ADAPTIVE PRODUCTS, FOLLOWING THE
MANUFACTURER'S RECOMMENDED PLACEMENT, AND FIELD
VERIFICATION OF CIRCUITS WITH RESPECT TO POWER PACK
PLACEMENT.
5. LIGHTING CONTRACTOR IS RESPONSIBLE FOR FIELD
VERIFICATION OF REQUIRED NUMBER OF POWER PACKS.
6. MODEL NUMBER ARE STANDARD NUMBERS. REFERENCE
PRODUCT MODEL NUMBER CHARTS FOR NAFTA AND ARRA
MODEL NUMBERS. LIGHTING CONTRACTOR IS RESPONSIBLE
FOR ORDERING THE APPROPRIATE MODEL.
7. CEILING MOUNTED SENSORS LOCATED OVER DOORWAYS
SHOULD BE PLACED ONE (1) FOOT OVER THRESHOLD.
8. APPROXIMATELY 5% OF U.S. LOCATIONS EXPERIENCE RF
INTERFERENCE OF WIRELESS DEVICES. MANUFACTURER
RECOMMENDS CHECKING THE SITE WITH A SIGNAL
STRENGTH METER TO EVALUATE APPROPRIATENESS TO
SITE CONDITIONS.
+8'-0" HARD LID
EXIT
+8'-0" HARD LID
(E)
(E)
(E)(E)
(E)(E)
(E)(E)(E)
(E)
(E)
(E)(E)
(E)
(E)(E)
J
J-BOX FOR
CEILING FAN
(FUTURE)
J J
J J
J J
J-BOX FOR
CEILING FAN
(FUTURE)
J-BOX FOR
CEILING FAN
(FUTURE)
(E)(E)
(E)
(E)
+9'-6"
PATIO HEIGHT
+9'-6"
PATIO HEIGHT
+9'-6"
PATIO HEIGHT
EX
I
T
J-BOX FOR
CEILING FAN
(FUTURE)
3-F35-F3
5-F35-F3
5-F3
5-F3
5-F3 5-F3
5-F3
5-F3
5-F3
5-F3
5-F3
5-F3
1-F3 1-F3
1-F3 1-F3
1-F3 1-F3
1-F3
1-F3
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
EXIT
(E)
EXIT(E)
EX
I
T
(E)
J
EXIT
EXIT
ELECTRICAL
LIGHTING PLAN
& LIGHTING
SCHEDULE
E2
NEW ASTRONOMICAL
TIMECLOCK BY
INTERMATIC #ET90215CE
OR APPROVED EQUAL
S
SS
S
40
NEW COLD WATER LINE
EXISTING COLD WATER LINE
P1
SEWER PLAN
NOTE:
-ALL WASTE PIPES THAT ARE SMALLER THAN 4"
MUST HAVE A MINIMUM SLOPE OF 2%. CPC 708.1
-ALL DOMESTIC HOT WATER PIPING TO HAVE THE
FOLLOWING MINIMUM INSULATION INSTALLED:
1/2" PIPE (1/2" INSULATION); 3/4" PIPE (1"
INSULATION);
1" - 1-1/2" PIPE (1-1/2" INSULATION). CPC 609.11 &
ES 150.0(j).
-CLEAN-OUTS ARE RE4UIRED TO %E INSTALLED
A%OVE ALL URINALS.
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
75
"
3
D
r
.
R
e
a
c
h
i
n
C
o
o
l
e
r
/
F
r
e
e
z
e
r
2
0
1
4
SODA
1 2 3 4 5 6
DISPENSER
(E)WALL MOUNTED
TAN.LESS WATER
HEATERS
(E)FLOOR SIN.
TO %E RELOCATED
RELOCATED
FLOOR SIN.
(E)FLOOR SIN.
(E)2"SWR
(E
)
2
"
S
W
R
(E
)
4
"
S
W
R
T
O
G
R
E
A
S
E
IN
T
E
R
C
E
P
T
O
R
(E)4"COTG
(E)4"COTG
(E)1500 GALLON GREASE
INTERCEPTOR
(E)2-WA<
4"COTG
(E
)
4
"
S
W
R
(E
)
2
"
V
E
N
T
T
O
G
R
E
A
S
E
IN
T
E
R
C
E
P
T
O
R
(E)3
"
S
W
R
(
E
)
3
"
S
W
R
(E
)
3
"
S
W
R
RELOCATED FLOOR
SIN.
(E)2"SWR
(E)VENT
(N
)
2
"
S
W
R
(N)VENT
(N)2"SWR
NEW FLOOR
SIN.
(E
)
3
"
S
W
R
(E)VENT
(N)3"SWR
(N)2%MIN
(E)VENT
MO
P
S
I
N
K
41
P2
WATER PLAN
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
75
"
3
D
r
.
R
e
a
c
h
i
n
C
o
o
l
e
r
/
F
r
e
e
z
e
r
2
0
1
4
(E)WALL MOUNTED
TANKLESS WATER
HEATERS
MO
P
S
I
N
K
SODA
1 2 3 4 5 6
DISPENSER
BB
AA
NEW COLD WATER LINE
E;ISTIN* COLD WATER LINE
INDIRECT WASTE
LINES
INDIRECT
WASTE LINES
(E)3/4"HW
INDIRECT
WASTE LINES
(E)3/4"CW
(E)3/4"CW
(E)3/4"HW
(E)3/4"CW
(E)3/4"CW
(E)3/4"HW
(N)1/2"HW (N)1/2"CW
INDIRECT
WASTE LINES
(E)3/4"CW
(E)3/4"HW
(N)1/2"HW(E)COLD
WATER LINE
(E)COLD
WATER LINE
42
EX
I
S
T
I
N
G
EX
I
S
T
I
N
G
CO
2
CO
2
A.03
MO
P
S
I
N
K
75
"
3
D
r
.
R
e
a
c
h
i
n
C
o
o
l
e
r
/
F
r
e
e
z
e
r
2
0
1
4
75
I
N
RE
A
C
H
I
N
C
O
O
L
E
R
BB
AA
B
&
B
SODA
1 2 3 4 5 6
DISPENSER
DOUBLE
SWING
DOUBLE
SWING
30
"
X
4
8
"
AC
C
E
S
S
I
B
L
E
1
2
3
4
5
30
"
X
4
8
"
AC
C
E
S
S
I
B
L
E
30
"
X
4
8
"
AC
C
E
S
S
I
B
L
E
Tr
a
s
h
E
n
c
l
o
s
u
r
e
Tr
a
s
h
E
n
c
l
o
s
u
r
e
TR
A
S
H
F F
F
F
F
F
FFFFFF
D
T
RR
P
K
E
J
H
C
B
A
G
M
P
P
P
A
AA
A
A
G
KM
N
H 2
R
Self Closing
Delivery Door
Self Closing Door
Entrance Self Closing Door
Entrance
Se
l
f
C
l
o
s
i
n
g
D
o
o
r
En
t
r
a
n
c
e
GAS
A K 4.1
K 4.1
A
1
1
J 02
A
0
3
E
0
1
E
0
3
E
0
4
D
0
1
D
0
2
D
0
3
D
0
4
D
0
5
B
0
3
B
0
1
A
0
5
A
0
8
A
1
0
A
0
6
A
0
7
G
0
1
G
0
1
G
0
1
G
0
3
G
0
5
G
0
2
G
0
2
G
0
4
GA
L
L
O
N
S
IN
OUT
SAMPLE
BOX
Raiser
Raiser
Raiser
O
N
S
I
T
E
A 02
1,
5
0
0
EX
I
S
T
I
N
G
E
0
5
A
0
9
A
0
4
B
0
4
A
1
0
D
0
6
G 04
G 04
G 04
G 04
G 04
G 04
G 04
G 02
G 01
G 01
G 01
B 05
G 03
J 03J 01
G 01
A 01
A 01 G
0
4
G
0
2
G
0
1
E 07
E 06
A
1
0
ELECTRICAL
PANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
ELECTRICAL
PANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
ELECTRICAL
PANEL
36" X 36"
CLEAR AREA
AMPS200
EXISTING
1 NOTE
3NOTE
3NOTE
3NOTE
3 NOTE
1 NOTE
3 NOTE
1 NOTE
2 NOTE
2NOTE
2 NOTE
1 NOTE 3NOTE
1
1
2
NOTE :CABINETRY, COUNTERTOPS & FURNITURE
NOTE :
NOTE :
NOTE :
NOTE :
NOTE :
NOTES :
Fiberglass Reinforced Paneling :
Flooring Finishing :
NOTE :
NOTES :
ELECTRICAL NOTES
PLUMBING NOTES
CONDENSATE NOTE :
NOTES :
C 03
C
NOTES :
C
F
F
RPDNOTE :BACKFLOW PROTECTION
Health Department Dry Storage Requirement
Item #
Item : High Performance Wired Shelving System
Description : Chrome Plated shelving , USDA acceptance for packaged
goods and long maintenance-free performance in dry enviroments.
Shelves and posts are plated with chome over a nickel chome base
Heavy load capacity and minimun dust accumulation for easy cleaning.
Item #Dimensions LengthQty Linear ft.
G 01
" Alps Village "
Food Service Equipment Plan1
NOTES :REQUIRED EXISTING
REQUIRED PROPOSED Total linear footage 16.0
Health Department Liquor Storage Requirement
Item #
Item : High Performance Wired Shelving System
Description : Chrome Plated shelving , USDA acceptance for packaged
goods and long maintenance-free performance in dry enviroments.
Shelves and posts are plated with chome over a nickel chome base
Heavy load capacity and minimun dust accumulation for easy cleaning.
Item #Dimensions LengthQty Linear ft.
G 02
G 02 2 8.0C18 " X 48 "4.0
G 02 1 5.0D18 " X 60 "5.0
G 01 4 16.0D18 " X 48 "4.0
FOODSERVICE NOTES
1
RESTROOMS DOORS
ARE
EXTERIOR WINDOWS
EXISTING FIXED
EXTERIOR DOORS
2
3
Floors Sinks Note :
Splash Guards Note :
Total linear footage 32.0
G 01 2 6.0C18 " X 36 "3.0
G 01 2 10.0E18 " X 60 "5.0Storage Area
Hallway Area
Janitorial Station
Trash Enclosure
Restrooms
Walk in Freezer
Cooking Area
Dining Area 1
Walk in Cooler
Dishwashing Area
Preparation Area
Service Area
Restroom Employee's2
Patio Area
Dining Area 2 ( New )
Floors Sinks Note :
Splash Guards Note :
G 02 1 3.0B18 " X 36 "3.0
FOOD SERVICE
EQUIPMENT
FLOOR PLAN
K 2.0
Hallway Area 2 2
FLOOR PLAN NOTES
4 WALK IN COOLER
PROPOSED
/ FREEZER FLASHING
A
B
C
D
E
G
H
H
J
K
K
M
P
R
R
T
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
43
44
45
46
EX
I
S
T
I
N
G
EX
I
S
T
I
N
G
( FAN / SWITCH ACTIVATED )
" MANUAL ON " "AUTO OFF "
75
"
3
D
r
.
R
e
a
c
h
i
n
C
o
o
l
e
r
/
F
r
e
e
z
e
r
2
0
1
4
SODA
1 2 3 4 5 6
DISPENSER
DOUBLE
SWING
DOUBLE
SWING
J
J+"
G 03 120
E6
J J
+
"
G
0
3
12
0
E6
J
+
"
A
0
3
90
J
+
"
D
0
4
36
J
+
"
B
0
3
18
+
"
A
0
4
60
+"
E 06 48
+"
D 0436
J+"
A 10 90
+"
A 1090J
+"
A 1090J
+"
A 1260
ALL WRITTEN DIMENSIONS AND HEIGHTS IN THIS PLAN ARE SHOWN AS A REFERENCE ONLY.
REAL DIMENSIONS AND HEIGHTS MUST BE DETERMINED BY FOODSERVICE CONTRACTOR AND
ELECTRICAL CONTRACTOR , REFER TO SHEET K-1 ( FOODSERVICE NOTES ).
ELECTRICAL CONTRACTOR SHALL EXAMINE ALL ELECTRICAL NOTES ,
FOODSERVICE EQUIPMENT SPECIFICATIONS AND ELECTRICAL
PLANS TO COMPLETELY UNDERSTAND THE EXTENT OF HIS
RESPONSIBILITIES.
HE SHALL RESOLVE ANY DISCREPANCIES ON THE FOODSERVICE
PLANS , ARCHITECTURAL PLANS OR ELECTRICAL SPECIFICATIONS
BEFORE COMMENCING WORK .
ELECTRICAL NOTES :
LIGHTING NOTE :
All lighting shall be shatterproof.
All lighting shall be in compliance with the applicable lighting
requirements for foodservice facilities ( including the 50 foot
candles of light in preparation and employee's areas where
safety is a factor )
NOTE :
Other Than Dwelling Units. All 125-volt, single-phase,
15- and 20-ampere receptacles installed in the locations
specified in 2IO.8(B)(1) through (8) shall have ground-fault
circuit-interrupter protection for personnel.
(1) Bathrooms
(2) Kitchens
(3) Rooftops
(4) Outdoors
Exception No. 1 to (3) and (4): Receptacles that are not
readily accessible and are supplied by a branch circuit
~/edicali?d 10 e/ffcfric snow-melting. deiciJlg. or pipeline and
'wssel healing equipmenl shall be permitted 10 be installed in
accordance with 426.28 uI"427.22. ill applicable.
Exception No. 2 to (4): In industrial establishments only,
where the conditions of maintenance and supervision ensure
that only qualified personnel are involved, an assured
equipment grounding conductor program as specified in
590.6(B)(2) shall be permittedfor only those receptacle outlets
used to supply equipment that would create a greater hazard if
power is interrupted or having a design that is not compatible
with GFCI protection.
(5) Sinks - where receptacles are installed within 1.8 m (6
ft) of the outside edge of the sink.
CEC 210.8 ( B )
NOTE :
The GFCI Specification is for both convenience outletsas well as
appliances .
JUNCTION BOX WIRE DIRECT TO EQUIPMENT
ROUGH-IN HEIGHT ( FROM FINISH FLOOR )
CONDUIT STUB OUT FROM CEILING
CONDUIT STUB OUT FROM FLOOR
VAPOR PROOF
120 VOLT DUPLEX RECEPTACLE
208 / 220 VOLT DUPLEX RECEPTACLE
ELECTRICAL LEGEND
J
SYMBOL DESCRIPTION
VP
F
E6NOTE
SCOPE
ORDINANCES AND REGULATIONS
PERMITS AND INSPECTIONS
VERIFICATIONS OF DIMENSIONS
SITE VISITATIONS
RECORD DRAWINGS
MATERIALS AND WORKMANSHIP
COORDINATION
C
NOTES :
C
F
" Alps Village "
Food Service Electrical Plan1
ROUGH IN NOTE :
FOOD SERVICE
ROUGH IN
ELECTRICAL PLAN
K 5.0
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
47
EX
I
S
T
I
N
G
MO
P
S
I
N
K
SODA
1 2 3 4 5 6
DISPENSER
BB
AA
DOUBLE
SWING
DOUBLE
SWING
GAS
A K 4.1
K 4.1
+
"
E
0
1
18
+
"
D
0
2
18
+
"
D
0
4
48
+
"
B
0
3
12
+
"
A
0
4
60
+"
J 02 24
10
10
+"
A 1090
+"
A 1090
+"
A 10 90
1
HEALTH DEPT.
1
NOTICE TO PLUMBING CONTRACTOR :
PLUMBING CONTRACTOR SHALL EXAMINE ALL PLUMBING NOTES ,
FOODSERVICE EQUIPMENT SPECIFICATIONS AND PLUMBING
PLANS TO COMPLETELY UNDERSTAND THE EXTENT OF HIS
RESPONSIBILITIES.
HE SHALL RESOLVE ANY DISCREPANCIES ON THE FOODSERVICE
PLANS , ARCHITECTURAL PLANS OR PLUMBING SPECIFICATIONS
BEFORE COMMENCING WORK .
ALL WRITTEN DIMENSIONS AND HEIGHTS IN THIS PLAN ARE SHOWN AS A REFERENCE ONLY.
REAL DIMENSIONS AND HEIGHTS MUST BE DETERMINED BY FOODSERVICE CONTRACTOR AND
PLUMBING CONTRACTOR , REFER TO SHEET K-1 ( FOODSERVICE NOTES ).
CGI
EFS
PLUMBING LEGEND
SYMBOL DESCRIPTION
VTR
Floor Troughs
( E * )
Manufacturer
Notes :
Water Heater data :
Model
Gas type
BTU
Minute @ 60 F Rise
Tankless Unit Gallons per6.5
RPDNOTE :BACKFLOW PROTECTION
Environmental Health Department
Hot Water Demands for Foodservice
Establishments ( Water Heater Calc's )
WATER HEATER CALCULATIONS
ROUGH IN NOTE :
( TANKLESS )
" Alps Village "
Food Service Plumbing Plan1
WATER BACKFLOW PREVENTION DEVICE
REDUCED PRESSURE PRINCIPLE ASSEMBLY
INDOOR HORIZONTAL INSTALLATION
WILKINS MODEL 975XL
(1/4", 3/8" AND 1/2" SIZES)FLOOR SINK
GRATE COVER
INDIRECT DRAIN
FINISH FLOORAIR GAP
1 INCH
TRAP PRIME
AIR GAP
DIRECTION OF FLOW
12
"
M
I
N
30
"
M
A
X
DETAIL 5.A
TO CARBONATION WATER
SYSTEMFROM WATER INLET
L 12
K 3.0
Ga
l
l
o
n
u
s
e
d
p
e
r
M
i
n
u
t
e
.
Pe
r
F
i
x
t
u
r
e
Fixture Description Sub-total
GPM No
t
e
s
.
TOTAL GALLONS PER MINUTE =
1
FOODSERVICE PLUMBING KEY NOTES
2
3
4
5
6
7
8
9
10
11
12
13
14
A)
B)
15
16 A 08 , A 09
NOTEFOOD SERVICE
PLUMBING
NOTE :
PLUMBING NOTES :
PLUMBING NOTES :
PLUMBING NOTES :
WITHIN THE CPC SECTION2022 704.3
PLUMBING SPECIFICATIONS
TESTING:
INSULATION:
DOMESTIC HOT WATER:
COLD WATER SERVICE:
WATER PIPING :
VALVES / FITTINGS :
SANITARY SEWAGE:
GAS
CPVC ( CLORINATED POLYVINYL CHLORIDE )
FOOD SERVICE
ROUGH IN
PLUMBING PLAN
K 6.0
Sheet: 1
File: ..\4.SPEC'S\NCC199-SPEC-3-2022.pdf
Missing or invalid reference
Sheet: 1
File: ..\4.SPEC'S\SPECS SMALL.pdf
Missing or invalid reference
6.5
3.0
19.5
NO. DATE REVISIONS
TITLE
SHEET NO.
OF:
DATE
AUG. 2024
DRN. BY
A.G.
SCALE
AS NOTED
APPROVED
Ramon Gutierrez (760)485-7003 / ramongwd@gmail.com
Adolfo Gutierrez (760)898-8210 / adolfogwd@gmail.com
PROJECT: A TENANT IMPROVEMENT FOR
Alps Village
Palm Desert, CA 92211
77-734 Country Club Dr.
Suites F1, F2 & F3
1 07/12/24 CUP 24-0004 CORRECTIONS
2 08/19/24 REMOVAL OF PATIO
CITY OF PALM DESERT APPROVAL STAMP
48
49
50
C I T Y O F P A L M
D E S E R T
73-510 FRED WARING DRIVE
PALM DESERT, CALIFORNIA 92260-2578
TEL: 760-776-6483
PLANNING@PALMDESERT.GOV
CITY OF PALM DESERT
PUBLIC HEARING NOTICE
CASE NO. CUP15-382, Amendment 1 (CUP 24-0004)
NOTICE IS HEREBY GIVEN THAT A PUBLIC HEARING WILL BE HELD BEFORE THE
PLANNING COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, TO ADOPT A
NOTICE OF EXEMPTION AND APPROVE A CONDITIONAL USE PERMIT AMENDMENT FOR
THE EXPANSION OF AN EXISTING RESTAURANT AT 77734 COUNTRY CLUB DRIVE, SUITE
F1.
The City of Palm Desert (City), in its capacity as the Lead Agency for this project under CEQA,
has determined that this project is Categorically Exempt from CEQA review in accordance with
Section 15301: Class 1 – Existing Facilities of the CEQA Guidelines.
PROJECT LOCATION: 77734 Country Club Drive, Palm Desert, CA 92211 (APN: 626-322-009
& 626-322-010)
PROJECT DESCRIPTION: A consideration to approve a Conditional Use Permit amendment to
allow for an expansion of an existing restaurant (Alps Village) at 77734 Country Club Drive. The
expansion would be an interior expansion into two additional suites and be for additional kitchen
and seating.
PUBLIC HEARING: NOTICE IS HEREBY GIVEN that the Planning Commission of the City of
Palm Desert, California, will hold a Public Hearing at its meeting on November 19, 2024. The
Planning Commission meeting begins at 6:00 p.m. in the Council Chamber at 73510 Fred Waring
Drive, Palm Desert, California. Pursuant to Assembly Bill 2449, this meeting may be conducted
as a hybrid meeting allowing public access via teleconference or in person. Options for remote
participation will be listed on the Posted Agenda for the meeting at
https://www.palmdesert.gov/departments/city-manager-s-office/city-clerk/committee-calendar.
PUBLIC REVIEW: The plans and related documents are available for public review Monday
through Friday from 8:00 a.m. to 5:00 p.m. by contacting the project planner, Carlos Flores. Please
submit written comments to the Planning Division. If any group challenges the action in court,
issues raised may be limited to only those issues raised at the public hearing described in this
notice or in written correspondence at or prior to the Planning Commission hearing. All comments
and any questions should be directed to:
Carlos Flores, Principal Planner
City of Palm Desert
73-510 Fred Waring Drive
Palm Desert, CA 92260
(760) 776-6478
cflores@palmdesert.gov
PUBLISH: THE DESERT SUN RICHARD D. CANNONE, AICP, SECRETARY
NOVEMBER 8, 2024 PALM DESERT PLANNING COMMISSION
51
52
CITY OF PALM DESERT
ATTENDANCE REPORT
Advisory Body:
Prepared By:
Year
Month
Date 2 16 6 20 5 19 2 16 7 21 4 18 2 19 6 20 3 17 1 29 7 21 5 20
DeLuna, Nancy --P P P P P -P P P P -E -P P -P P --P -1 0
Greenwood, John --P E P P P -P P P E -E -P P -P P --P -3 0
Gregory, Ron --P P P P P -P P E P -P -E E -P P --P -3 0
Holt, Lindsay --P P E P E -P P P P -P -P P -P E --E -4 0
Pradetto, Joseph --P P P P P -P P P P -P -P P -P P --P -0 0
Palm Desert Municipal Code 2.34.010:
P Present
A Absent
E Excused
-No meeting
R Remote
2024 2024 2024 2024 2024
Total
Absences
Oct Nov Dec
PLANNING COMMISSION
Niamh Ortega/Michelle Nance
2024 2024
Twice Monthly: Six unexcused absences from regular meetings in any twelve-month period shall constitute an automatic resignation of
members holding office on boards that meet twice monthly.
Total
Unexcused
Absences
Jan Feb Mar Apr May Jun Jul Aug Sep
2024 2024 2024 2023 2023