HomeMy WebLinkAboutRes No 1319PLNIW G COMIISSICN REZ X JIZQd ND. 1319
A RESOLUTION OF THE PLANNING CCNMISSION OF THE CITY OF PALM
DESERT, CALIFORNIA, SETTING FORTH ITS FINDINGS AND
APPROVING A PARCEL MAP THAT COMBINES THREE EXISTING LOTS
INTO ONE PARCEL ON THE WEST SIDE OF CORPORATE WAY AT LENN1ON
PLACE.
CASE N0. PM 21557
WHEREAS, the Planning Cannission of the City of Palm Desert, California,
did on the 1st day of November, 1988, hold a duly noticed public hearing to
consider the request mentioned above; and
WHEREAS, said application has complied with the requirements of the "City
of Palm Desert Procedure for Implementation of the California Environmental
Quality Act, Resolution No. 80-89," in that the director of community
development has determined that the project is a class 15 categorical
exemption; and
WHEREAS, at said public hearing, upon hearing and considering all
testimony and argunents, if any, of all interested persons desiring to be
heard, said planning cannission did find the following facts and reasons to
exist to justify recammnding approval of the parcel map:
1. That the proposed map is consistent with applicable general and
specific plans.
2. That the design or improvement of the proposed parcel map is
consistent with applicable general and specific plans.
3. That the site is physically suitable for the type of development.
4. That the design of the parcel map or the proposed improvements are
not likely to cause substantial environmental damage or substantially
and avoidably injure fish or wildlife or their habitat.
5. That the design of the parcel map or the type of improvements are not
likely to cause serious public health problems.
8. That the design of the parcel map or the type of improvements will
not conflict with easements, acquired by the public at large, for
access through or use of property within the proposed subdivision.
NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of
Palm Desert, California, as follows:
1. That the above recitations are true and correct and constitute the
findings of the commission in this case.
2. That it does hereby approve the above described Tentative Parcel Map
No. 21557, subject to fulfillment of the attached conditions.
PLANNIN3 CENNIISSION RESOLUrIai ND. 1319
PASSED, APPROVED and ADOPTED at a regular meeting of the Palm Desert
Planning C mmission, held on this 15th day of November, 1988, by the following .r
vote, to wit:
AYES: DOWNS, LADLOW, RICHARDS, WHITLOCK, AND ERWOOD
NOES: NONE
ABSENT: NONE
ABSTAIN: NONE
ATTEST:
w101:4;:nr161)11
RANDN A. DIAZ, S
/tm
2
F ICE rAR� ER4DOD, chairman
use
PLANNING CCNNIISSICN RFSOIJUTICN NO. 1319
CONDITIONS OF APPROVAL
CASE NO. PM 21557
Department of Oznuu city Developient:
1. All condition of Planning CLnmission Resolution No. 1046, PP 85-10 and
11, PP 85-21, Resolution Nos. 1071 and 1138 shall apply to this case.
Department of Public Wb ks:
1. Storm drain construction shall be contingent upon a drainage study by the
private engineer that is approved by the department of public works.
2. All on -site improvements shall be inspected by the engineering department
and a standard inspection fee shall be paid prior to recordation of the
final map.
3. Landscaping maintenance on Corporate Way shall be provided by the property
owner.
4. Complete grading plans and specifications shall be submitted, as required
by ordinance, to the city engineer for checking and approval prior to
recordation of the final map.
5. 0ffsite improvement plans to be approved by public works department and a
surety posted to guarantee the required offsite improvements prior to
recordation of the final map.
6. Canplete parcel map shall be submitted as required by ordinance to the
city engineer for checking and approval and be recorded before issuance of
any permits.
7. All conditions applied to PP 85-21 shall be applicable to this parcel map.
City Fire Marsha;.:
1. Install a water system capable of delivering 3500 GPM fire flow from any
fire hydrant for a 3 hour duration in addition to domestic supply. The
computation shall be based upon a minimum of 20 psi residual operating
pressure in the supply main from which the flow is measured at the time of
measurement.
2. Install Riverside County super fire hydrants so that no point of any
building is more than 200 feet from a fire hydrant measured along approved
vehicular travel ways.
3
PLANNING CavtlISSICtsl RE SOLUTION N0. 1319
a. exterior surface of hydrant barrels and heads shall be painted chrome
yellow, and the tops and nozzle caps shall be painted green.
b. curbs shall be painted red 15 feet in either direction from each
hydrant.
c. hydrants shall not be located closer than 25 feet to any building.
3. Prior to issuance of a building permit, the developer shall furnish the
original and three copies of the water system plan to the fire marshal for
review. Upon approval, one copy will be sent to the building department
and the original will be retuned to the developer.
4. The water system plan shall be signed by a registered civil engineer and
approved by the water company with the following certification: "I
certify that the design of the water system in PM 21557 is in accordance
with the requirements prescribed by the fire marshal."
5. Prior to delivery of combustible materials to the building site, the
required water system shall be installed, operating and delivering the
required flow.
6. Additional fire protection requirements may be necessary when the
applicant submits plans for consideration and approval.
7. All buildings over 5,000 square feet require an approved fire sprinkler
system.
/tm
4