Loading...
HomeMy WebLinkAboutRes No 1998PLANNING COMMISSION RESOLUTION NO. 1998 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, APPROVING AN AMENDMENT TO CONDITIONAL USE PERMIT 90-14 TO INCREASE THE STUDENT CAPACITY TO 96 AND ADD A 36' x 40' MODULAR CLASSROOM BUILDING LOCATED AT 73-930 SANTA ROSA WAY. CASE NO. CUP 90-14, AMEND. #1 WHEREAS, the Planning Commission of the City of Palm Desert, California, did on the 18th day of July, 2000, hold a duly noticed public hearing to consider the request of LAKSHAMAN WICKREMESINGHE for the above mentioned use; and WHEREAS, said application has complied with the requirements of the "City of Palm Desert Procedure for Implementation of the California Environmental Quality Act, Resolution No. 00-24," in that the Director of Community Development has determined that the project is a Class 1 Categorical Exemption for purposes of CEQA and no further documentation is necessary; and WHEREAS, at said public hearing, upon hearing and considering all testimony and arguments, if any, of all interested persons desiring to be heard, said Planning Commission did find the following facts and reasons to exist to justify the granting of said amendment to Conditional Use Permit: 1. That the proposed location of the conditional use is in accord with the objectives of the zoning ordinance and the purpose of the district in which the site is located. 2. That the proposed location of the conditional use and the conditions under which it will be operated and maintained will not be detrimental to the public health, safety or general welfare, or be materially injurious to properties or improvements in the vicinity. 3. That the proposed conditional use will comply with each of the applicable provisions of the Zoning Ordinance, except for approved variances or adjustments. 4. That the proposed conditional use complies with the goals, objectives, and policies of the City's adopted General Plan. 1 PLANNING COMMISSION RESOLUTION NO. 1998 NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of Palm Desert, California, as follows: 1. That the above recitations are true and correct and constitute the findings of the commission in this case. 2. That approval of Amendment #1 to Conditional Use Permit 90-14 is hereby granted, subject to the attached conditions. PASSED, APPROVED and ADOPTED at a regular meeting of the Palm Desert Planning Commission, held on this 18th day of July, 2000, by the following vote, to wit: AYES: NOES: ABSENT: ABSTAIN: ATTEST: PHILIP DRELL, Secretary Palm Desert PI nning Commission PEZ, airperson 2 PLANNING COMMISSION RESOLUTION NO. 1998 low CONDITIONS OF APPROVAL CASE NO. CUP 90-14, Amendment #1 Department of Community Development: 1. The development of the property shall conform substantially with exhibits on file with the Department of Community Development, as modified by the following conditions. 2. Construction of a portion of said project shall commence within one year from the date of final approval unless an extension of time is granted; otherwise, said approval shall become null, void and of no effect whatsoever. 3. The development of the property described herein shall be subject to the restrictions and limitations set forth herein which are in addition to all municipal ordinances and state and federal statutes now in force, or which hereafter may be in force. 4. The property is subject to all conditions of approval set forth in approval of Conditional Use Permit 90-14 and Resolution No. 1465. 5. Prior to issuance of a building permit the applicant shall merge properties referred to as A.P.N.(s) 627-121-042, 627-121-027, and 627-121-028 into lot. 6. Applicant shall obtain agreement from Valley Christian Assembly for long- term use of a minimum of 18 spaces in the adjacent parking facility. If in the future the agreement is terminated and parking spaces are no longer available, the conditional use permit is subject to revocation. 7. Capacity of the facility shall be limited to 96 children. Riverside County Fire Department: 8. Install a fire alarm system as required by the UBC Chapter 3. 9. Install portable fire extinguishers per NFPA 10, but not Tess than one 2A1OBC extinguisher per 3,000 square feet and not over 75' walking distance. A "K" type fire extinguisher is required in all commercial kitchens. 10. All buildings shall be accessible by an all weather roadway extending to lim. within 150' of all portions of the exterior wall of the first story. The 3 PLANNING COMMISSION RESOLUTION NO. 1998 roadway shall not be less than 24' of unobstructed width and 13'6" of vertical clearance. Where parallel parking is required on both sides of the street the roadway must be 36' wide and 32' wide with parking on one side. Dead-end roads in excess of 150' shall be provided with a minimum 45' radius turn -around 55' in industrial developments. 11. Whenever access into private property is controlled through use of gates, barriers or other means provisions shall be made to install a "Knox Box" key over -ride system to allow emergency vehicle access. Minimum gate width shall be 16" with a minimum vertical clearance of 13'6". 4