Loading...
HomeMy WebLinkAboutRes No 2013PLANNING COMMISSION RESOLUTION NO. 2013 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF PALM DESERT, CALIFORNIA, APPROVING A PRECISE PLAN OF DESIGN FOR 2 TWO-STORY OFFICE BUILDINGS (23,550 SQUARE FEET OF TOTAL BUILDING AREA) AND A PARCEL MAP WAIVER TO ADJUST PROPERTY LINES ON 2.9 ACRES ON THE WEST SIDE OF COOK STREET 280 FEET NORTH OF GERALD FORD DRIVE (PARCELS 3 AND 4 OF PMW 00-05), 74-950 GERALD FORD DRIVE. CASE NOS. PP 00-07 AND PMW 00-05 WHEREAS, the Planning Commission of the City of Palm Desert, California, did on the 5th day of September, 2000, hold a duly noticed public hearing to consider the request by Basic Capital Management for the above project; and WHEREAS, said application has complied with the requirements of the "City of Palm Desert Procedure for Implementation of the California Environmental Quality Act, Resolution No. 00-24," in that the project was reviewed as part of a Negative Declaration of Environmental Impact which was prepared and certified in 1997, pursuant to City Council Ordinance No. 838, and no further documentation is necessary; and WHEREAS, at said public hearing, upon hearing and considering all testimony and arguments, if any, of all interested persons desiring to be heard, said Planning Commission did find the following facts and reasons more fully delineated in the staff report dated September 5, 2000 to exist to justify approval of said precise plan: 1. That the proposed location of the precise plan is in accord with the objectives of this title and the purpose of the district in which the site is located. 2. That the proposed location of the precise plan and the conditions under which it will be operated and maintained will not be detrimental to the public health, safety or general welfare, or be materially injurious to properties or improvements in the vicinity. 3. That the proposed precise plan will comply with each of the applicable provisions of this title. 4. That the proposed precise plan complies with the goals, objectives and policies of the City's adopted general plan. PLANNING COMMISSION RESOLUTION NO. 2013 NOW, THEREFORE, BE IT RESOLVED by the Planning Commission of the City of Palm Desert, California, as follows: 1 . That the above recitations are true and correct and constitute the findings of the Commission in this case. 2. That Precise Plan 00-07 and PMW 00-05 on file in the Department of Community Development are hereby approved, subject to conditions. PASSED, ADOPTED and APPROVED at a regular meeting of the Palm Desert Planning Commission, held on this 5th day of September, 2000, by the following vote, to wit: AYES: CAMPBELL, FINERTY, JONATHAN, LOPEZ, BEATY NOES: NONE ABSENT: NONE ABSTAIN: NONE ATTEST: PHILIP DRELLSecretary Palm Desert Panning Commission 2 PAUL R. BEATY, Chairpers n it PLANNING COMMISSION RESOLUTION NO. 2013 CONDITIONS OF APPROVAL CASE NOS. PP 00-07 AND PMW 00-05 Department of Community Development: 1. The development of the property shall conform substantially with exhibits on file with the Department of Community Development/Planning, as modified by the following conditions. 2. Construction of a portion of said project shall commence within one year from the date of final approval unless an extension of time is granted; otherwise said approval shall become null, void and of no effect whatsoever. 3. The development of the property described herein shall be subject to the restrictions and limitations set forth herein which are in addition to all municipal ordinances and state and federal statutes now in force, or which hereafter may be in force. 4. Prior to issuance of a building permit for construction of any use contemplated by this approval, the applicant shall first obtain permits and/or clearance from the following agencies: Coachella Valley Water District Palm Desert Architectural Review Commission City Fire Marshal Public Works Department Evidence of said permit or clearance from the above agencies shall be presented to the Department of Building and Safety at the time of issuance of a building permit for the use contemplated herewith. 5. Access to trash/service areas shall be placed so as not to conflict with parking areas. Said placement shall be approved by applicable trash company and Department of Community Development. 6. Should the applicant choose to create an illuminated parking lot or illuminate the building exterior, a detailed parking lot and/or building lighting plan shall be 3 PLANNING COMMISSION RESOLUTION NO. 2013 submitted for staff approval, subject to applicable lighting standards per Ordinance No. 826, plan to be prepared by a qualified lighting engineer. 7. All sidewalk plans shall be reviewed and approved by the Department of Public Works prior to Architectural Review Commission review of final landscape plan. 8. Project is subject to Art in Public Places program per Palm Desert Municipal Code Chapter 4.10. 9. Final landscape plans shall comply with the parking lot tree planting master plan. 10. Applicant agrees to maintain the landscaping required to be installed pursuant to these conditions. Applicant will enter into an agreement to maintain said landscaping for the life of the project, which agreement shall be notarized and which agreement shall be recorded. It is the specific intent of the parties that this condition and agreement run with the land and bind successors and assigns. The final landscape plan shall include a long-term maintenance program specifying, among other matters, appropriate watering times, fertilization and pruning for various times of the year for the specific materials to be planted, as well as periodic replacement of materials. All to be consistent with the Property Maintenance Ordinance (Ordinance No. 801) and the approved landscape plan. The project shall be subject to all applicable fees at time of issuance of permits, including, but not limited to, Art in Public Places, TUMF and school mitigation fees and low income housing mitigation fee. 12. That the westerly street shown on Exhibit B-2 of PMW 00-05 shall be constructed and open to regular vehicular traffic prior to issuance of Certificate of Use and building final sign off by Planning Department. Department of Public Works: P.P. 00-07: 1. Any drainage facility construction required for this project shall be contingent upon a drainage study prepared by a registered civil engineer that is reviewed and approved by the Department of Public Works prior to start of construction. 4 PLANNING COMMISSION RESOLUTION NO. 2013 The project shall be designed to retain storm waters associated with the increase in developed vs. undeveloped condition for a 100 year storm. 2. Signalization fees, in accordance with City of Palm Desert Resolution Nos. 79- 17 and 79-55, shall be paid prior to issuance of any permits associated with this project. 3. The project shall be subject to Transportation Uniform Mitigation Fees (TUMF). Payment of said fees shall be at the time of building permit issuance. 4. A complete preliminary soils investigation, conducted by a registered soils engineer, shall be submitted to, and approved by, the Department of Public Works prior to the issuance of a grading permit. 5. All public and private improvements shall be inspected by the Department of Public Works and a standard inspection fee shall be paid prior to issuance of grading permits. 6. Any and all offsite improvements shall be preceded by the approval of plans and the issuance of valid encroachment permits by the Department of Public Works. 7. As required under Palm Desert Municipal Code Section 26.28, and in accordance with Sections 26.40 and 26.44, complete improvement plans and specifications shall be submitted to the Director of Public Works for checking and approval before construction of any improvements is commenced. Offsite improvement plans to be approved by the Public Works Department and a surety posted to guarantee the installation of required offsite improvements prior to permit issuance. 8. Landscape installation on the property frontages as well as on -site shall be drought tolerant in nature and maintenance shall be provided in the same manner specified above. 9. Applicant shall comply with the provisions of Municipal Code Section 24.12, Fugitive Dust Control and Section 24.20, Stormwater Management and Discharge Control. 10. In accordance with Palm Desert Municipal Code Section 26.44, complete grading plans/site improvement plans and specifications shall be submitted to 5 PLANNING COMMISSION RESOLUTION NO. 2013 the Director of Public Works for checking and approval prior to issuance of any permits. 11. Proposed building pad elevations are subject to review and modification in accordance with Chapter 27 of the Palm Desert Municipal Code. 12. Full public improvements, as required by Sections 26.40 and 26.44 of the Palm Desert Municipal Code, shall be installed in accordance with applicable City standards and the city's Circulation Network. Those improvements shall include, but not be limited to the following: * Installation of concrete curb, gutter and paving on the proposed access street. * Installation of dedicated right turn lane approximately 100 feet in length with a 90 foot reverse curve and an acceleration lane approximately 120 feet in length with a minimum 150 foot taper, for the Gerald Ford Drive/proposed access street intersection. * Installation of a concrete sidewalk in an appropriate size and configuration on the proposed access street. Rights -of -way necessary for the installation of the above referenced improvements shall be dedicated to the city prior to the issuance of any permits associated with this project. 13. The intersection of the proposed access street and Gerald Ford Drive shall be limited to right turn movements only, or as approved by the City Engineer. PMW 00-05: 1. Prior to the recordation of a Certificate of Compliance for the subject parcel map waiver, applicant shall apply for reapportionment of any existing city assessments impacted by the proposed parcel map waiver. 2. Prior to the recordation of the Certificate of Compliance for the subject parcel map waiver, applicant shall dedicate street right-of-way as indicated on the PMW plat. 6 PLANNING COMMISSION RESOLUTION NO. 2013 Riverside County Fire Department: 1. With respect to the conditions of approval regarding the above referenced plan check, the Fire Department recommends the following fire protection measures provided in accordance with City Municipal Code, NFPA, UFC, and UBC and/or recognized Fire Protection Standards: The Fire Department is required to set a minimum fire flow for the remodel or construction of all commercial buildings per UFC article 87. 2. A fire flow of 1500 gpm for a 1 hour duration at 20 psi residual operating pressure must be available before any combustible materials is placed on the job site. 3. Provide, or show there exists a water system capable of providing a gpm flow of 3000 for commercial buildings. 4. The required fire flow shall be available from a wet barrel Super Hydrant(s) 4"x 2-1/2"x 2-1/2") located not Tess than 25' or more than 150' from any portion of a commercial building measured via vehicular travelways. 5. Water plans must be approved by the Fire Marshal and include verification that the water system will produce the required fire flow. 6. Install a complete NFPA 13 fire sprinkler system. This applies to all buildings with a 3000 square foot total cumulative floor area. The Fire Marshal shall approve the locations of all post indicator valves and fire department connections. All valves and connections shall not be Tess than 25' from the building and within 50' of an approved hydrant. Exempted are one and two family dwellings. 7. All valves controlling the water supply for automatic sprinkler systems and water -flow switches shall be monitored and alarmed per UBC Chapter 9. 8. Install a fire alarm system as required by the UBC Chapter 3. 9. Install portable fire extinguishers per NFPA 10, but not less than 2A10BC extinguisher per 3000 square feet and not over 75' walking distance. A "K" type fire extinguisher is required in all commercial kitchens. 7 PLANNING COMMISSION RESOLUTION NO. 2013 10. Install a Hood/Duct automatic fire extinguishing system per NFPA 96 in all public and private cooking operations except single-family residential usage. 11. Install a dust collecting system per UFC Chapter 76 if conducting an operation that produces airborne particles. 12. All buildings shall be accessible by an all-weather roadway extending to within 150' of all portions of the exterior walls of the first story. The roadway shall not be less than 24' of unobstructed width and 13'6" of vertical clearance. Where parallel parking is required on both sides of the street the roadway must be 36' wide and 32' wide with parking on one side. Dead-end roads in excess of 150' shall be provided with a minimum 45' radius turn -around 55' in industrial developments. 13. All buildings shall have illuminated addresses of a size approved by the city. 14. All fire sprinkler systems, fixed fire suppression systems and alarm plans must be submitted separately to the Fire Marshal for approval prior to construction. 15. Conditions subject to change with adoption of new codes, ordinances, laws, or when building permits are not obtained within twelve months. 8