Loading...
HomeMy WebLinkAboutELPU18-0028City of Palm Desert PERMIT NUMBER: ISSUED DATE: Building and Safety Department ELPU18-0028 73510 Fred Waring Drive 51412018 12:00:00 AM Palm Desert, CA 92260 Permit Type: ELECTRICAL PANEL Appl. Date: 5/4/2018 - UPGRADE Appr. Date: 5/4/2018 Permit Subtype: Exp. Date: 10131/2018 Job Valuation: $450.00 Project Address: 73372 ADOBE SPRINGS DR Project Description: PEDESTAL PANEL UPGRADE 100 TO 200AMP APN1Tract/Lot No: Owner: Contractor: Applicant: 620093030 LYNNA R YOUNG RENOVA ENERGY CORP RENOVA ENERGY CORP TR 4181 73372 ADOBE SPRINGS DR 75-181 MEDITERRANEAN AVE 75-181 MEDITERRANEAN AVE 55 PALM DESERT, CA 92260 PALM DESERT, CA 92211 PALM DESERT, CA 92211 (760)568-3413 (760)568-3413 Licensed Contractor Declaration Fee Summary, rem under penally of pariury that I am licensed under provisions of Chapter 9 ammencinby affirg with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect, ARCHIVE FEE - 8.5Xi t UP TO 11X17 GL-11000OO-34116DO $0.35 ELECTRICAL PANEL UPGRADE GL-1100000,3221100 $159.00 Initial GREEN BLDG FEE SB1473 GL-61o000D-2281060 $1.00 PERMIT ISSUANCE FEE GL-1100000-3411400 $105.00 Owner -Builder Declaration i hereby affirm under penalty of Podury that I am exampt from the Contractors' State Total Fees Paid: $265.35 License Law for the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) Section 7031.5 Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to Issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law(Chapter 9(commenctng with Section 7000) of Division 3 of the Business and Professions Cade) or that he or she is exempt and the basis for the alleged print Name: exemption. Any violation of Section 7031.6 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($50D).) I, as owner of the properly, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sate (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to Signarureof Applicant or Agent; an owner of property who builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or Improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.} Dale: I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Cade: The Contractors License Law does not apply to an owner of property who builds Or improves thereon, and who contracts for such projects with a licensed contractor pursuant to the Contractors' Slate License Law.) I am exempt from Licensure under the Contractors' State License Law for the following reason: Date/Signature of property owner or agent workers' Compensation Declaration WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CML PINES UP TO ONE HUNDRED THOUSAND DOLLARS 4$100.000), IN ADDITION TO THE COST OF COMPENSATION DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEYS FEES. I hereby affirm under the penalty of parfury ONE of the following declarations: I have and will maintain a certificate of consent to seifAnsure for workers' compensation, Issued by the Director of Industrial Relations as provided for by Section mitt 37DO of the Labor Code, for the performance of the work forwhich this permit issued. Policy No. I h ve and will maintain workers' compensation insurance, as required by Section Co of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Initial Carrier& Policy Number Expiration Date 1 certify that in the pe formance oft ark fa ich this permit is Issued, t shall not employ any person in any manner o a to eco a subject the workers' compens on I cos Of CBliforn{a nd a that 1 1 should ome subject to the workers' rape sation prov sip s v ct n 37 cf the L r Cade, I shall th comp ththe a dons. Initial Data. Applicant City of Palm Desert Department of Building and Safety Building Permit Application (For Office Use Only) JOB ID: `_kN 1� oi a� PLANS FILED: Project Address: 73372 Adobe Springs Drive suite # Total Value of work: $ 450.00 . Note: Plan Review Fees may be adjusted after Plan Review Project Description (be specific): PANEL UPGRADE 100A Main Service Pedestal to 200A Milbank Pedestal Contractor Business Name Renova Energy Corp. Property owner Name L nna Young y g Address 75181 Mediterranean Ave. Address 73372 Adobe Springs Drive city Palm Desert 92211 Zip City Palm Desert ZIP 92260 Phone 760-568-3413 Phone (760) 568-3413 Fax Fax 5-mall permits@renovasolar..com E-mail Contractor license No. 910836 ❑Architect Name ©Designer Name Engineer Name Address Address city zip city ZIP Phone Phone Fax Fax E-mall E-mail License No. License No. AwAllcant_Name signature Date Christian Cordero 14118 Contact Telephone Number E-Mail CITY O sN_�: DESERT 760-568-3413 permits@renovaenergy.CGffl� :q7.MENT OF J APPROVED SY: ❑ C.0 RES. RCS � __-- s '41FF LETTER ❑ P.C. RES. h10 __E) ARC ACTION Fi`W1 73-510 Fred Waring Drive,'Palm Desert, CA 92260 • (760) 776-6420 • (760) Misdfi3 'swv�z+rAcktyofpaimdesert.org N w u m D N n D m [5 m m Z 0 '' I0n;z0 CcC-)o (� - m m z-0 r- C:0 n Xcnmj° dm 0 ir a D +n X r1j rn n `n 0 n 0 r W OCn�rn On a-j;m t Z X o m o o OC C) 0 (,OR'O,mO z =-I 1 K -a 0 M D 21)MMKC Li a o -4 r- Z Z co m m 0 m m m m 10 ❑ N ❑ A L. L. m m m G O r- C) r- p m m 0 rn II m > C na m in Z N szQW�Q� Iv in o O C -0 N O a)Re � m m o w_ m A 0 z m�m�'e0M O itm O O M 0 6 � ca m f!1 W N m C: II z m D [nmmmvt v P n N 9 qq m m m C6;o n 0 Co si co 0 W O O A N C C 3 O O -t W 3� 7J Z w O M❑ O n @ 2 v N m mynn z X It D rn Z m -n D m Gl C n N m m 5� Zcn o mO Z m m m n D n n LAX; m a y y c m m z z n j Z ,X Cn I 0 o m 70 m 0 D T C z n ^' O z m O M -o O rD ❑ O p �Nt,1 Z x a y D D Z 0 m Y �] 0 m rn m 0 y i v � o � N o a I I rn A fr: o ❑ m rn T to z 0 K n M z OC D � ❑ m O m0 -C'I i m o T �I M 9 m O 0 0 m o g m 0 o X Y , z �-ziwa n 20 ° r 0 z X 0 m N O M v m -OI r0 0 r � >p cn A N N n Ku m m m z a m � � O 'a a m w O p D A CD0 C7 7] P T O M Gt � rmo ::On z II II o To; Q c:v ZQZ$ Czz M;o xn0 G)�z 0) ;MQ r0D0 m Z ;c0 800 �p0 =ati] M m O A G� m 7J r O n 0 z Y - ti N 4 � n C7 E Z 0 Z Z Z C # m G m n 0 M W 0 A = = Z 0(n m0 n C0 O N 0 n — Cn co Koom 0 0� m m � 9 D o m� fA N c � m m r_rt 4 C 0 Co x� a� (-)0 Oo0i3 a�oa IN ZK O-Dm-u n z Mo m x r0 a O❑ � (Mn n uz "I rN�ffn1 O+ Z .'tml X ❑ � N z y � b m rn m Cm \y M z 1 0 m M r"*M4= 0QKm-v QI ' --I � ❑ConM OOQrm ZrkjX z:-I M 0 n m 40 >0 X Sr F5 Om ra D mC rn m z� d T. -0a m n ;0oa :zC '0MZ 0 z m mb -M'x n� qm N m � N O O �z N C W 7 a o ❑ Project Nama: c o Q m W LYNNA YOUNG (1333595) D ,�� o ren©va.energy r- N O o N= p '� 3 r " Renova Energy Corp 73372 ADOBE SPRINGS DRIVE n� c - 75-181 Mediterranean Ave, s Palm Desert, CA 92211 C: W p PALM DESERT, CA. 92260 �¢ 9 ' Q66}5683413 ril K Contractor's Licanso#91C836 renova,e nerg 1J t SINGLE-FAMILY DWELLING - LOAD CALCULATION !+' NEC 2014 Edition: Following Example Annex D2(b) Customer Name: Lynn@ Young; 73372 Adobe Springs Dr., Palm Desert, CA 92260 1. OTHER LOADS - 220.42 a. General lighting loads - 220.42 1,440 sq.ft. x 3 VA = first 3,000 @ 100%, remaining @ 35% < 120,000 VA 3,462 VA b. Small appliance loads - 220.14 1,500 VA x 4 C. Laundry- 220.52(B) 2 Special Loads - 220.53, 220.54 Dishwasher = Disposal = Compactor = Water heater ( if Gas =0) _ Oven- 220.55 = Cook Top - Pool = Outside plugs (2) _ Clothes Dryer = Microwave = First 10,000VA x 100% = Remaining 12,674 VA x 40% Net Load for Items 41 and #2 circuits = 2. HEATING OR A/C LOAD -Table 220.82(C)(3) Heating units (3 or less) = VA x 65% Heating units (4 or more) = VA x 40% A/C unit # 38479 = 5,418 VA x 100% Net Load VA SERVICE: I = V SERVICE: I = 20,488 VA = 240 V Service amperes required 85.4 A Service amperes provided 200 A 2/28/2018 RJ 6,000 VA 1,200 VA 972 VA 672 VA 0 VA 0 VA 0 VA 0 VA 0 VA 3,840 VA 5,040 VA 1,488 VA (Subtotal) 22,674 VA 10,000 VA 5,070 VA 15,070 VA 0 VA VA 5,418 VA (Total #2 = Largest Load) 5,418 VA (Total #1 +Total #2 = Largest Load) 20,488 VA 85.4 A < 200-Ampere rated New Circuit Breaker