HomeMy WebLinkAboutPLUM18-0006 PERMIT EXPIREDCity of Palm Desert
Building Safety
PERMIT NUMBER:
ISSUE DATE:
and Department
rr 73510 Fred Waring Drive
pLUM78-0006
Palm Desert, CA 92260
Permit Type: PLUMBING
Appl. Date: 2/9/2018
,.
Permit RE -PIPE OR REPAIR
Subtype:
Job Valuation: $26,332.00
Appr. Date:
Exp. Date:
Project Address: 74130 ASTER DR
Project Description: WHOLE HOUSE REPIPE
APN/TractfLot No:
Owner:
Contractor:
Applicant:
624204001
WILLIAM VICTOR MARTIN
GENERAL AIR CONDITIONING &
GENERAL AIR CONDITIONING &
SHADOW VILLAGE 1
74130 ASTER DR
PLU
PLU
49
PALM DESERT, CA 92260
31170 RESERVE DR
31170 RESERVE DR
THOUSAND PALMS, CA 92276
THOUSAND PALMS, CA 92276
(760)343-7488
(760)343-7488
Licensed Contractor Declaration
Fee Summary
I hereby affirm under Penalty of oedury that lam licensed under provisions of Chapter 9
ARCHIVE FEE - 8.5X11 UP TO 1IX17 GL-1100000-3411600 $0.21
V
(commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my license is in full force and effect.
GREEN BLDG FEE SB1473 GL-0100000.MJ OOO $8.00
Initial
MINIMUM INSPECTION FEE GL-1100000-3221100 8159.00
PERMIT ISSUANCE FEE GL-1100000-3411400 $105.00
Owner -Builder Declaration
1 hereby affirm under penalty of penury that I am exempt from the Contractors' State
Total Fees Paid: $272.21
License Law for the reason(s) indicated below by the checkmark(s) I have placed next
i hereby affirm under the penalty of perjury that there is a construction lending agency for the
to the applicable items) Section 7031.5 Business and Professions Code: Any city or
performance of the work for which this permit is issued (Sea 3097, Civil Code)
county which requires a permit to construct, alter, improve, demolish, or repair any
Lenders Name and address
structure, prior to Issuance, also requires the applicant for the permit to (Ile a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State
Asbestos Declaration
License Law(Chapter 9(commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she Is exempt and the basis far the alleged
n of Section 31.
exemption.pplicttAnyviolation by any applicant for a permit subjects the
Written asbestos notification pursuant to Part 61 Of Title AO of the Code of Federal Re ulations is required
q
pen re n
applicant to a civil penalty of not more than five hundred dollars {5500).)
when asbestos exists in buildings, or portions thereof, undergoing demolition. I hereby declare that
I, as owner of the property, or my employees with wages as their sate compensation,
demolition authorized by this permit is from construction that does or does not contain
asbestos, or that no demolition Is authorized by this permit,
wM do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to
es for this permit in accordance with CA Gov Code Sec. 66020
NOTICE: You may prole yPoarrangements
an owner of property who builds or improves the property, provided that the
(a). The protest must Iy hments of Gov. Code See.66020(a) and must be filed within 90
improvements are not intended or offered for sale. If, however, the building or
days cf the date of thi o . 1n, you must tender payment of the protested fees at the time of
improvement is sold within one year of completion, the Owner -Builder will have the
the payment or 'd e e to pay the protested fees or exactions at the time they
burden of proving that it was not built or Improved for the purpose of sale.)
are due If they of due.
I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project (Sec. 7044, Business and Professions Code: The Contractor's
1
License Law does not apply to an owner of property who builds or Improves thereon,
and who contracts for such projects with a licensed contractor pursuant to the
Contractors' State License Law.)
I am exempt from Licensure under the Contractors' State License Law for the
following reason:
Date/Signature of property owner or agent
Workers'Compensation Declaration
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS {S100,000), IN ADDITION TO THE COST OF COMPENSATION DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEYS FEES,
/
t hereby affirm under the Penalty of Deriury ONE of the fallowing declarations:
I have and will maintain a certificate of consent to self -Insure for workers'
compensation, issued by the Director of Industrial Relations as provided for by Section
3700 of the Labor Code, for the performance of the work for which this permit issued.
Initial
Policy No.
have and will maintain workers' compensation insurance, as required by Section
illI
3700 of the Labor Code, for the performance of the work for which this permit Is
Issued. My workers' compensation insurance carrier and policy number are:
Carver & Policy Number
Initial
Expiration Date
1 certify that In the performance of the work for which this permit Is Issued, I Shall not
employ any person in any manner so as to become subject to the workers'
V[
_
compensation laws of California and agree that if I shout hecome subject to the
workers' compensation provisions of Section 3700 of the abor Code, I shall forthwith
comply with those provisions.
Initial
V
Datec(Z Applicant
City of Palm Desert
;r Department of Building and Safety
Buildint Permit Application
(For Office Use Only)
JOB ID: PL,14AA 19 - 000(a
PLANS !FILED:
Project Address: 14-110 tr C \+ e_ Wi m -e 2 ( � Suite #
Total Value of work: $. Z11,5 31 ' D O Note: Plan Review Fees maybe adjusted after Plan Review
Project Description (be specific): Jk) e !LAAA o _ I � 1.,I _,�Ar � .- : ffi
Contractor B sinass Na a
rat,
Property Gunner Name
!� f I1.F
1
I Address t V /1t t' .�G
Address
�
i
G/
r Yam.
City p Zip pp
city 4
* + ram* .%(k
Zip
PhoneI
3A -.I_ L.
Prong
—...._._._
S
lt�
Fax
tLa!]-
Email { Y C( 1 t (1, l -
F_. %Y� C Y1.t. er 1,
Gantractar L erase No. �
E-mail --
�Yl
1
)
�t
rchit
Aect Name esigner Name
F
�n
Engineer Nance
Address
i F .: @ rt i Of W '�-.-
City Zip
Address
city
._
Zip
Phone q n q rf
Phone
Fax
Fax
- __................. ....................�
E-mail y
��f� �'-
E-mail
License No. '
I� Ga
License No.
PLEASE COMPLETE THE REVERSE SIDE
73-510 Fred Waring Drive, Palm Desert, CA 92260 • (760) 776-6420 • (760) 776-6392 fax - www.cityofpalmdesert.org
i3RC7DUCTS GROUP
Innofoam
Thickness Recommendations* -To Control Cnndensafinn
Pipe Size I Line Temp. 50°F I Line Temp. 30°F
Line Temp, 0°F
Normal Conditions (Max 85°F-70%RH)
3/8"I1) through 2" IPS
318" Wall
1/2" Wall
1" Wall
Over 2" IPS through 4" IPS
1/2" Wall
1/2" Wall
1" Wall
Mild Conditions (Max 80°F-50%RH)
3/8"ID through 3" IPS
34' Wall
3/8" Wall
1/2" Wall
Over 3" IPS through 4" IPS
1/2" Wall
1/2" Wall
112" Wall
Severe Conditions (Max 90°F-80%RH)
3/8"ID through 4" IPS 1 3/4" Wall 1 1" Wall
LSP Products Group, Inc.
*lnnofoamO in thickness noted within the specific temperature ranges will prevent condensation on indoor piping tinder the design conditions listed
below:
3689 Arrowhead Dr.
Normal: Maximum severity of indoor conditions seldom exceed a5`F and 70%RH in the United States.
Carson City, NV 89706
Mild: Typical conditions are most air-condi&oned spaces and acid climates,
Severe: Generally found In areas under which excessive moisture is introduced or in poorly ventilated areas where temperature may be depressed
Phone: (800) 854-3215
below the ambient. Under conditions of high humidity, additional insulation may be required.
Compatible with CPVC piping.
Fax (800) 243-1777
PRODUCT SPECIFICATIONS
Ph. (877-372-5833)
Toll free
Thermal conductivity, Btu - in/h • ft2 - °F [W/(m•K)] ASTM C 177 or C518
75°F (24°C) mean temp 0.25 (0.036)
Email: info@lspproduGtS.com Ispproducts.com
Water vapor transmission, ASTM E 96 (Dry Cup)
Web: www.ls _products,com
perm -in [g/(s-m-Pa)] 0.005 (7.25x10-12) (max)
Flame and smoke ratings 25/50 ASTM E 84
up to and including 1" thicknesses (25mm)
Nominal density, Ibs/cu.ft (Kg/cu.m) 1-1/2 (24) ASTM D 1622
Ozone Resistance GOOD ASTM D 1171
Upper use limit, °F (°C) 200 (93)
Lower use limit, °F (°C) -200 (-129)
Sizes
Wall thickness (nominal) 318", 1/2", 314" and 1" - (10, 13, 19 and 25mm)
Inside diameter, tubular form 3/8" to 4-1/2" ID - (10mm ID to 114mm ID)
Length of sections, tubular form 6' (1,83m)
Nominal
R Value
R Value
R Value
R Value
Id
3/8"Wall
1/2"Wall
3/4" Wall
1" Wall
318
2,73
3.85
6.35
9.11
112
2.62
3.66
5.95
8.49
518
2.57
3.54
5.70
8.07
3/4
2.67
3.60
5.66
7.93
7/8
2.28
3.15
5.07
7.20
1
2.36
3.21
5.07
7.13
1118
2.17
2.98
4.76
6.72
1114
2.33
2.13
4.88
6.80
1318
2,11
2.88
4.56
6.41
1518
2.22
2.97
4.59
6.36
2
1.84
2.53
4.03
5.66
2118
2.02
2.71
4.20
5.83
2 318
2.03
2.71
4.16
5.74
2 518
2.05
2.71
4.13
5.68
2 7/8
2.07
2.72
4.12
5.62
3118
2.09
2.73
4.10
5.58
3112
2.10
2.73
4.08
5.52
3 518
2.11
2.74
4.08
5,51
4118
2.17
2.78
4.09
5.48
4 112
2.21
2.82
4.11
5.47