HomeMy WebLinkAboutROOF18-0277City of Palm Desert PERMIT NUMBER: ISSUE DATE: Building and Safety Department ROOF18-0277 73510 Fred Waring 9114l2018 260 Palm Desert, CA 92260 Permit Type: RE -ROOF Appl. Date: 911412018 Permit RESIDENTIAL Appr. Date: 9/1412018 Subtype: Job Valuation: $26,922.00 Exp. Date: 3/13/2019 Project Address: 29 AVENIDA ANDRA Project Description: CRRC 0628-0002 APNITractlt-ot No: Owner: Contractor: Applicant: 624300035 THOMAS ALLEN MARSCHEWSKI R D WINKLE COMPANY R D WINKLE COMPANY TR 21698 1816 FREEBORN WAY P 0 BOX 476 P 0 BOX 476 29 SANTA ROSA, CA 93012 THOUSAND PALMS, CA 92276 THOUSAND PALMS, CA 92276 (760)322-5144 (760)322-5144 Licensed Contractor Declaration Fee Summary i hereby affirm under penally of oe6ua that I am licensed under provisions of Chapter 9 ARCHIVE FEE - 8.5X11 UP TO 11X17 Gi A I M000-3411600 $0.28 commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. GREEN BLDG FEE SB1473 GL.6100000-2281000 $2.OD — Initial MINIMUM INSPECTION FEE GL-11D0o00-3221100 $159.OD PERMIT ISSUANCE FEE GL-1100000-3411400 $105.00 Owner -Builder Declaration I. hereby affirm under penalty of pa6ury that I am exempt from the Contractors' State Total Fees Paid: $266.28 l herebyafFfrm under the penalty of perjury that there is a construction fending agency for the License Law for the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) Section 7031.6 Business and Professions Code: Any city or performance of tho work for which this permit is issued (Sec 3097, Civil Code) county which requires a permit to construct, alter, Improve, demolish, or repair any Lenders Name and address structure, prior to issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State Asbestos Declaration License Law(Chapter 9(commencing with Section 7DOD) of Division 3 of the Business and Professions Code) or that he or she is exempt and the basis for the alleged exemption. Any violation of Section 31.6 by any applicant for a permit subjects the Written asbestos notification pursuant to Pad 61 of Title 40 of the Code of Federal Regulations is required applicant le a civil penalty of not morere than five hundred dollars ($540).y when asbestos exists in buildings, or portions thereof, undergoing demolition. I hereby declare that 1, as owner of the property, or my employees with wages as their sole compensation, demolition authorized by this permit is from construction that does Dr does not contain asbestos, or that no demolition is authorized by this permit. will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to NOTICE: You may protest any of the fees for this permit In accordance with CA Gov Code Sec. 66020 an owner of property who builds or improves the property, provided that the (a). The protest must satisfy the requirements of Gov. Cade Sec,66020(a) and must be filed within 90 improvements are not intended or offered for sale. If, however, the building or days of the date of this notice. In addition, you must tender payment of the protested fees at the time of improvement is sold within one year of completion, the Owner -Builder will have the the payment or provide ovldence of arrangements to pay the protested fees or exactions at the time they burden of proving that it was not built or improved for the purpose of sale,) are due if they are not already due. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code:7he Contractors License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a licensed contractor pursuant to the Contractors' State License Law.) I am exempt from Licensure under the Contractors' Slate License Law for the following reason: Dire of property owner or agent Workers' Compensation Declaration WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL AND SHALT. SUBJECTAN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDMON TO THE COST OF COMPENSATION DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEYS FEES. . I hereby affirm under the penalty of perikiONE of the following declarations: have and will maintain a certificate of consent to seifinsure for workers' Compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work forwhich this permit issued. Initial Policy No. I have and will maintain workers' compensation insurance, as required by Section 3700 Df the Labor Cade, for the performance of the work for which this permit is saved. My workers' compensation insurance carrier and policy number are: Initial Carrier & Policy Number Expiration Dale I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California and agree that if I should become subject to the wecompensation provisions of Section 3700 of the Labor Cope I shall forthwith Initial comply with those provisions. Date 57-/Applicant ✓ln' goo -7 06 City of Palm Desert (For Office Use Only) Department of Building and Safety 1 0-'� `1 JOB iD: Building Permit Application PLANS FILED: Project Address: 29 Avenida Andra, Palm Desert CA. 92260 _ Suite Total Value of work: $ 26, 922.00 I Note: Plan Review Fees may be adjusted after Plan Review Project Description (be specific): Re -Roofing of the Low -Slope Roofing Systems The Low -Slope Roofs will receive a new 60mil TPO Roofing System The existing SPUF roof will remain in place, the new TPO roof will be an Overlay Contractor Business Name R. D. Winkle co. Property Owner Name Lear 1 Marschewski Address P.O. Box 476 Address 29 Avenida Andra City Zip Thousand Palms 92276 City Zip Palm Desert 92260 Phone 760-322-5144 Phone Fax 760-322-5244 Fax E-mail Ryan@RDWinkleRoofing.com E-mail Contractor License No. 688062 I]Architect Name ❑Designer Name Engineer Name Address Address City Zip city Zip Phone Phone Fax Fax E-mail E-mall License No. License No, Applicant Name Signature Date / / l Ryan A. Winkle /0 • �/� 9-14-2018 Contact Telephone Number E-Mail 760-272-0003 Ryan@RDWinkleRoofing.com PLEASE COMPLETE THE REVERSE SIDE 73-510 Fred Waring Drive, Palm Desert, CA 92260 • (760) 776-6420 • (760) 776-6392 fax • www.cityofpalmdesert.org WINKLEco ROOF CONSTRUCTORS Ra�tinp a SularSyst�ms 760-322-5144 Roofing Proposal for The Lear Residence 29 Avenue Andra Palm Desert, CA. 92260 9 WINKLEc.0 ROOF CONSTRUCTORS Reefing & 84ft Systems Tuesday, August 21, 2018 Amy Lear 29 Avenue Andra Palm Desert, CA. 92260 Attn: Ms. Amy Lear & Mr. Bob Reimers Re: Low -Slope Roofing System Replacement This proposal is in regard to the above referenced project. All items discovered and recommendations are based from a recent nonintrusive inspection of the low -slope roofing system. We are proposing the replacement of the low -slope roofing system. The existing low - slope roof is a Spray Polyurethane Foam (SPUF) roofing system with an elastomeric coating system. This is roofing system is in very poor condition. It appears at some point the protective coating system had deteriorated which in turn resulted in the foam being exposed and burning. Due to the damaged to the foam this roofing system is beyond repair This house was built in 1990, making the roofing system approximately 28 years old. The average usable life span for low -slope roofing systems is approximately 15-20 years in our desert climate. This roofing system has exceeded its usable life expectancy. The proposed new roofing system for the low - slope roofs will consist of 60 mil Thermoplastic Polyolefin (TPO) membrane over a '/2" SecurShield HD Polyiso roof board. The design of this roofing system is a joint specification between R. D. Winkle co. & the materials manufacture Carlisle Syntec Systems. We have also provided an option for a 45mil TPO roofing system. Furnishings and installations will be as explained below; Uiermoplasstic Poyokfln {TPO,) Roofing &stem Sized Leations Demolition & Clean Up: RDW will remove the loose debris from the surface of the existing low -slope roof. All large blisters will be cut out and removed. All exposed fasteners from the existing roofing systems will be pulled from the substrate, this will give a cleaner surface for the preparations of the new roofing system and will in sure that the old fasteners will not puncture the new material. All roofing debris on the ground will be swept up and the grounds will be rolled with a magnet to pick up any fasteners or metal scraps that had fallen during the demolition. RDW will dispose of all roofing waste. P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lic. #688062 1:3 ED WINKLOO ROOF CONSTRUCTORS Belsi ng &Svwsystems. T ha ma clastic Pal ode n P Roofing stem &ecifications SecurShield HD Polyiso: This product is used as an underlayment for the Thermoplastic Polyolefin (TPO) roofing system. The SecurShield HD Polyiso will provide a clean surface for the new roofing system. SecurShield HD Polyiso is a'/z" rigid roof insulation board that consists of a high -density closed cell polyisocyanurate foam core with a coated fiberglass mat facing. This material provides strength against wind uplift, while delivering an additional 2.5 R-value to the roofs insulation value. The SecurShield HD Polyiso will be fastened to the substrate using 3" plates and Carlisle HP fasteners. The SecurShield HD Polyiso will be installed to I-90 specifications. Thermoplastic Polyolefin (TPO): This is a single ply mechanically attached roofing system. We will be installing Carlisle Syntec Sure -Weld 60mi1-reinforced membrane. The TPO roofing system has many benefits over conventional built-up roofs (BUR). This is a sure weld membrane meaning that all seams are heat welded together, compared to either hot tar in a built up roof or an open flame used in torch on roofs. The field will be seamed with a robotic heat welder giving a continuous and consistent weld. Details, such as flashings and corners will be welded manually. Welds will then be checked with a probe. The parapet walls will also receive the 60mil-reinforced membrane. The Carlisle Syntec Sure -Weld 60mil-reinforced TPO membrane is much safer, cleaner, and does not produce any unpleasant odor when being installed. Other positives to this roofing system are that the TPO membrane is highly reflective and helps reduce energy consumption cost, it will provide a long term resistance to the punishing ultraviolet rays we receive here in the western states. This system meets California Title 24 specifications. The TPO roofing system will be installed to the manufactures specifications. Flashings and Corner Details: All vent pipe flashings will receive a pre -manufactured TPO boot flashing, the collars will be sealed with cut off mastic and galvanized clamps. All inside and outside corner details will receive pre -manufactured non -reinforced TPO corners. All flashings and corners will be manually welded and then check with a probe for quality control. TPO Sheet Metal: RDW will supply and install the following TPO coated sheet metal; T-Top Vents. If additional TPO cladded sheet metal is desired to be installed by RDW there will be an additional cost. Otherwise all other TPO cladded sheet metal is to be supplied by and installed by others. P.Q. Box 476, Thousand Palms, California 92276 • (760) 322-5144 Fax (760) 322-5244 Lic. #688062 1:3 ED WINKLEc.0 ROOF CONSTP U C T O R S Reefing &SOWUMORS Additional Information Galvanized Sheet Metal: RDW will supply and install the following galvanized sheet metal; termination bar and counter flashing. If other sheet metal is desired to be installed by RDW there will be an additional cost. Otherwise all other sheet metal is to be supplied by and installed by others. Roof Drains and Expansion Couplings: RDW will be replacing the expansion couplings on all main and overflow roof drains. This is rubber based flexible part which connects the roof drain furnishing to the plumbing, this part loses its integrity over time and frequently cracks or becomes disconnected. For the Thermoplastic Polyolefin (TPO) roofing system all roof drains will also be replaced, this is due to the requirement of clamping rings. New cast iron or copper roof drains will be installed with new expansion couplings. Skylight Replacement: The two (2) existing double dome skylights will be removed and disposed of. The unit will be broken down and recyclable materials will be recycled. The existing wood curb will be cleaned in preparation for the new weather seal. Any remaining sealant will be removed and disposed of prior to the new sealant. New EPDM weather stripping will be installed to the existing wood curb. This weather seal will be mechanically attached and adhered to the existing curb. The new skylight will be manufactured by Solar Industries. The new skylights will be double dome. All skylights will have an opaque exterior lens with a clear interior lens and a mil finished frame. The Flat Glass Pyramid skylight at the front entry will remain in place, this skylight is not being replaced. Damaged. PIywood & Fascia: Damaged plywood, board or other substrate will need to be replaced. Since we cannot see if there is any or how much damaged wood there is this is not included into the contract amount. RDW can remove and replace any damaged plywood sheeting at $ 65.00 per sheet. Other substrates will be removed and replaced at a time and material based cost. Exclusions: Permit not included, permit can be provided at cost. Removal and reinstallation of any equipment; AC units, solar panels, lines and etcetera are excluded. Any item/s not noted though the visible inspection of the roofing systems are excluded. Any items that are not specified in the above information are not included. Contract amount valid for 30 days from labeled date. P.O. Box 476, Thousand Palms, Califomia 92276 - (760) 322-5144 Fax (760) 322-5244 Lie. #688062 h � . WINKLEM ROOF CON STRU CTO R S Reef ng &. ,syste_ t Warranty Information RDW Warranty: RDW will warranty the roofing system for a period of five years (5). If the roofing systems are annually maintained in a Roof Maintenance Program by R D Winkle Company during the applicable warranty period, the warranty for these roofing systems will be extended to ten years (10). Please see WORKMANSHIP, MATERIALS AND SYSTEMS WARRANTY for more information. 20 Year Manufacture Material Warranty: The 60mil Thermoplastic Polyolefin (TPO) roofing system is covered by the a 20 year Manufacture Material Warranty from Carlisle SynTec, See Carlisle SynTec Material Warranty for more information. ContractAmounts 60mil Thermoplastic Poiyolefin (TPO) System with SecurShield HD: $ 26,922.00 Accepted By: Respectfully Submitted, ,:00 ye Ryan A. Winkle Supervisor/Estimator Date: Initial P.O. Box 476, Thousand Palms, California 92276 - (760) 322-5144 Fax (760) 322-5244 Lie. #688062 CITY OF PALM DESERT PERMIT #REJU- 2Z7 Building & Safety Department 73-510 Fred Waring, Palm Desert, CA (760) 776-6420 SMOKE & CARBON MONOXIDE ALARM RETROFIT 2016 California Residential Code sections R314.t3 and R315.2 Where a permit is required for alterations; repairs or additions exceeding E1,000, including exterior work, i.e. roofing, HVAC change-*Uts, electrical panel upgrades, windows, etc. existing dwelling or sleeping units that have attached garages or fuel burning appliances including fireplaces shall have a carbon monoxide alarm. Smoke and Carbon monoxide alarms shall be Installed In the following manner In each sleeping room (only require Smoke Alarms unless bedrooms contain a gas appliance then a carbon monoxide alarm is required as well) • outside each separate sleeping area in the immediate vicinity of the bedrooms. (require Smoke and Carbon Monoxide Alarms) • In each story level of the dwelling, including basements and habitable attic rooms (require Smoke and Carbon Monoxide Alarms) • Smoke alarms and smoke detectors shall not be located where ambient. conditions, including humidity and. temperature are outside the limits specified by the manufacturer's published instructions • Installation near bathrooms. Smoke alarms shall be installed not less than a 3 ft. horizontal distance from the door or opening of a bathroom that contains a. bathtub: or shower unless this would prevent placement of a smoke alarm required by other sections of the code • Smoke alarms and smoke detectors shall not be installed within 36 in. horizontal path from the supply registers of a forced air heating or cooling system and shall be installed outside of the direct airflow from those registers • Smoke alarms and smoke detectors shall not be installed within a.36 in. horizontal path from the tip of the blade of a ceiling -suspended (paddle) fan • Smoke Detectors shall be within 10 years of manufacture marked date and/or replaced if such date does not exist • -Conventional Ionization smoke alarms must be installed with a ten year battery Interconnection: Where more than one carbon .monoxide alarm is required to be installed within the dwelling unit or within a sleeping. unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms. Exception: Interconnection is not required in existing dwelling units where repairs do not result In the removal of wall and ceiling finishes, or there is no access by means of attic, basement or crawl space. The Building Inspector will verify the installation of the smoke and carbon monoxide alarms during the Inspection. process or the owner can complete and sign under the penalty Of perjury the following: I understand the above requirements and certify that we now have smoke alarms and carbon monoxide alarms installed that comply. I agree to comply with the CRC In regards to smoke alarms and carbon monoxide alarms. and 1, who own and/or litre In the (Property Owner's name) p ` (Tenant's nsrnalsome ) Dvtcefl locarted a : � `lT�;?�ti)A P03p* % � 3 _�- �22_14 Signature of 91ner Date Signature of Tenant Hate *This is ar voluntary smoke and carbon monoxide alarm verification procedure, If you prefer a building Inspector to perform the verifon, your must arrange to have an adult present at the time of inspection. 'Note, this verdreation is only used when normal access to the interior of the dwelling is trot achieved during the course of project construction. It is normally used for projects such as re -roofing, re -siding, Patio covers or swimming pools. 411112017 Page! I of 1