Loading...
HomeMy WebLinkAboutCC RES 81-050RESOLUTION N0. 81-50 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF PALM DESERT, CALIFORNIA, AUTHORIZING AN ALTERNATE METHOD OF "FIRE PROTECTION" FOR ZERO LOT LINE CONSTRUCTION WHERE FEE-SIP1PLE OWNERSHIP OF ADJACENT LOT IS INVOLVED. I WHEREAS,,the adoption of the 1979 Uniform Building Code modifies � the existing techniques of construction now in effect; and, WHEREAS, Staff has researched and provided sufficient information and drawings for approval by the Board of Appeals; and, WHEREAS, enhancement of architectural design as well as construc- tion costs are a part of this consideration; and, WHEREAS, it is the consideration of this body that the alternate method provides protection equal to or greater than minimum Codes; NOW, THEREFORE, BE IT RESOLVED that the City Council, by this Resolution, authorizes the alternate methods provided under Attachments A& B and under the provisions of Section 105 of the 1979 Uniform Building Code and makes this alternative an available option for construction. PASSED, APPROVED, and ADOPTED by the City Council of the City of Palm Desert, California, on this 26 th day of Marc h , 1981, by the following vote to wit: AYES: TZcPherson, Newbrander, Puluqi, Snyder & Wilson NOES: None ABSENT: None ABSTAIN: None , ATTEST: ' + `/ "• J / SFiEiLA ^R. GILLIGAN, City C1 CITY OF PALM DESERT, CALIFORNIA � ZERO PROPERTY LINE FIREWALL CONSTRUCTION TYPICP.L ST:?CKcD RCO�= APPi :Ck�:ON � S r�.r.s. • . • . ._ •. � �. _ t \ J .. .. •� \ t ] � • • I_ • 1 ... _ . . 5' CEILING RETURN WITH 5/8" TYPE "X" TO ROOF SHEATHING (TYPICAL BOTN SIDES) FACE LAYER NAILED WITH 8d COOLER NAILS AT 7" O.C. (TYPICAL BOTH SIDES) NOTE: ROOF RAFTER AND WALL STUD SPACING AT 16" O.C. MAX. OR PROVIDE CROSS � STRIPP�NG AT 16" O.C. MAX. FOK DRYWALL (FIRE RATED) �NAILING PURPOSES. NOTE: THE SAh1E CONDITIONS APPLY REGARDLESS OF PITCH OF ROOF. •�. `� o' , � ° y� 6. RESGL. 81-1, EXHIBIT A 51 Nr,s . �_�..._-....__.�....�.+! L��. JJ.. s��...---"-' t- / 2 x BLOCKING r 2 LAYERS 5/8" TYPE "X" � STAGGERED JOINTS BASE LAYER NAILED WITH 6d COOLER NAILS AT 9" O.C. REQUIRED WALL AND CEILING INSULATIOfJ � APP � � 3-l7, R � C K, AIR AN DA"iE BOA'!�D OF APPEALS AND CONDEMNATION g. � �'. e . •o � t'A � •. � ' `Q� � iI�O , 0 � `�. �r . A ; `.�o . � ° �� �' � c Q' , '� bQ o ' '`♦ v v, � , � ,, �i � l • '* �;• •..�• •' �B , • ��.f�� o� ��� � ������ 45-275 PRICKLY PEAR LANE, PALM DESERT, CALIFORNIA 92260 TELEPHONE (714) 346-0611 March 17, 19$1 Drawings of Resolution 81�1, Exhibits A and B meet the intent and stipulations of the Board of Appeals regarding alternate methods as presented to the Board on Thursday, March 12, 1981. The Exhibits are hereby approved. ,., �,,,,�,..,,,,. OF APPEALS & CONDEMNATION JLH:Ich � �. , Z� ., PROPERTY LINE FIREWALL CONSTR� ION TYPICAL TRUSS ROOF APPLICATION 51 v►��� . N?�. .. _. . .r •_ • � .: • . _ . «. _ . • _ _ .- REQUIREQ CEILING AND WALL INSULATION TYPICAL 5' HORIZONTA� RETURN OF 5/8" TYPE "X" DRYWALL WITH VERTICAL RETURN TO ROOF SHEATHING (TYPICAL BOTH SIDES) NOTE: UERTICAL RETURN TO ROOF SHEATHING MAY BE OP�ITTED IF ENTIRE CEILING OF ROOM ADJACENT TO PARTY � WALL IS COVERED WITH 5/8" TYPE "X" DRYWALL. S' � w�rN. N.Ts . - —r�-- -- =• _ .... .. . ..... � -....•. • . ... . �.. ••.. ._-....�., . . P�OTE: SPACE TRUSSES AT 16" O.C. OR PROVIDE CROSS STRIPPING 16" O.C. FOR CEILING (FIRE RATED) NAILING. n n�. r� �r�y r� � PROVIDE EDGE BACKING FOR NAILING 5/8" CEILING (i.e. 2 X BLOCK TYPICAL BOTH SIDES) 2 X STUDS AT 16" O.C. MAXIMUM. / 2 LAYERS 5/8" TYPE "X" DRYWALL EXTENDING TO ROOF SHEATING BASE LAYER NAILED WITH 6d COOLER NAILS AT 8" O.C. FACE LAYER NAILED WITH 8c COOLER NAILS AT 7" O.C. (TYPICAL BOTH SIDES) / � APPRVD: �' AL K, CHAIRMAN DA7E BOARD OF APPEALS AND CONDEMNATION e � s �, b �. b� V .� U I� v ` d � +_ v p rJ F o C • , i I � r y � 0 • • � (y • D- 1 f a RESOL. 81-1, EXHIBIT B