HomeMy WebLinkAboutPlymo-Vent Diesel Exhaust-Capturing System at Fire StationsREQUEST: SUBMITTED BY: DATE: ATTACHMENTS: CITY OF PALM DESERT DEVELOPMENT SERVICES STAFF REPORT APPROVAL OF A $140,797.48 EXPENDITURE TO PURCHASE AND INSTALL THE PLYMOVENT DIESEL EXHAUST CAPTURING SYSTEM AT ALL CURRENT CITY FIRE STATIONS Stephen Y. Aryan, Assistant to the City Manager February 28, 2008 1) PlymoVent Proposal 2) PlymoVent Product Description 3) Fire Department Correspondence RECOMMENDATION By Minute Motion: 1. APPROVE the Proposal by Air Cleaning Systems (Pomona, CA) in the amount of $140,797.48 to install the PlymoVent Diesel Exhaust Capturing System at Fire Station No. 33, Fire Station No. 67, and Fire Station No. 71. Funds are available from the New Construction Tax Fund account 231-4220-422-4001. Discussion: The Palm Desert Fire Department requests the installation of the PlymoVent Diesel Exhaust Capturing System at the three City Fire Stations (Fire Stations No. 33, 67, and 71). The PlymoVent system is a hose on an overhead track rail structure that connects to the exhaust of the fire apparatus, in capturing and expelling virtually 100% of the diesel exhaust emissions through a built-in ventilation filtering system. Nearly all the Fire Department's fleet operates on diesel fuel, the emission of which are being expelled into the work and living quarters of the fire station. In an effort to mitigate firefighter exposure to these diesel emissions, the Fire Department is requesting installing of this exhaust capturing at all current and future City Fire Stations. The Fire Department is indicating that PlymoVent is the standard for Riverside County Fire Department stations and is a sole source vendor. They are unique from competitor systems in providing a pneumatic collar attaching to the vehicle. The pneumatic collars are specifically designed for the PlymoVent Exhaust System resulting in compatibility and fleet standardization. Fire personnel assert that other vendors' venting systems will include additional retrofitting of apparatus or facilities resulting in increased costs. PlymoVent Diesel Exhaust Capturing System February 28, 2008 Page 2of2 PlymoVent is also requested because of its compatibility with other jurisdictions' systems in use such as Cathedral City and Palm Springs. When Mutual Aid coverage is needed or provided between jurisdictions, the system and design features are compatible for use between these Fire Departments. The per station cost to install at all City of Palm Desert Fire Stations is as follows: STATION Fire Station No. 33 Fire Station No. 67 Fire Station No. 71 TOTAL Submitted by: Stephen Y. Aryan Assistant to the C' y Manager Approved by: Carlos L. Ortta City Manager COST $79,289 $25,944.74 $35,563.74 $140,797.48 Reviewed by: Paul S. Gibson Director of Finance/City Treasurer Da id City Atto*rfey /rrr p1.0-1 I -Romer L. Croy CITY COUNyCIL Manager APPROVED RECEIVED ION: DENIED OTHER P.MEETINC DATE a AYES: NOES: ' -i?l1 K�.11y 1e� �,x� eY1:`y j. AF3SEWL : ABSTAIN: t) nQ- G \DevServices\Stephen Aryan\Word Data\Agenda Repo is\PlymoVent Proposal StFIED BY V [ CON 1i7�Ct Original on File wi T71 City Clerk's O-1=f:;_c;, A���J Proposal AIR CLEAN/NG SYSTEMS California License#772590;Nevada License#56619 Specializing in Industria/Ventilation and C/ean Arr Solutions TO: CITY OF PALM DESERT LOCATION: 73510 FRED WARING DR RIVERSIDE COUNTY STATION#33 PALM DESERT CA 92260 ATTN: Steve Aryan APPLICATION: VEHICLE EXHAUST 60-0340-N1O20 I 760-863 7072 I P ebrPuOary 6 2 OSE I EXPIRATION DATE ( PRO 06SA 6154 I QTY ITEM NO. DESCRlPTION UNIT PRICE AMOUNT 3 STRA-75 Straight Rail System 75 Irtcludes: 3- 19'of Extruded Aluminum Profile; 1-14.25'of Extruded 7,864.00 23,592.00 Aluminum Profile; 1-End Socket w/Sealing Lid and Rubber Endstop(Rear); 150' Rubber Lip; 7-Top Suspension Mounts; 3-Rail Splicing Sleeve(Internal); Note: Must order end cap of choice, rubber bumper or hydraulic shock separately. 1 STRA PLYMOVENT STRA Hose Pack#1 includes:(For Center Bay) 2,685.00 2,685.00 HOSEPACK (1}-4"lnternal Crab w/Regulator and Balancer #1 (1)-4"x 25' Hose Assembly (1)-4"x 2'lower hose Assy including Safety Disconnect and&6.26"Grabber (1)-STRA-Magazine Pack#1 & 100'Coiled Airline 2 STRA PLYMOVENT STRA Hose Pack#2 includes:(For Outside Bays)2 VehiGes each bay 5,350.00 10,700.00 HOSEPACK (2)-4"Internal Crab w/Regulator and Balancer(each rail) #2 (2)-4"x 25'Nose Assembly(each rail) 2 Vehicles (2)-4"x 2' lower hose Assy including Safety Disconnect and&626"Grabber(each rail) (2)-STRA-Magazine Pack#1 & 100'Coiled Airline(each rail) 1 MOUNTING Includes all PLYMOVENT mounting material,supports,dedicated compressor,filter/dryer 2,750.00 2,750.00 MATERIAL regulator, pneumatic fittings and engine sensors for automatic start of fan when any engine is started. Also includes(5)tailpipe adapters for apparatus tailpipes. 1 TEV-585-60 PLYMOVENT high pressure BI fan,7.5 HP,m 3 phase,6 drop,top horizontal, 10"inlet 1,948.00 1,948.00 3810-A081 1 OS-3 PLYMOVENT UL LISTED Control Operation System for 7.5 HP,208v, 3 phase, 19 amp fan 867.00 867.00 706043 listed above. Electrical or pneumatic connection,hook-ups,or fire suppression, BY OTHERS PERMITS required to install or operate,or anv concrete aad are responsibility of BUYER INSTALLATION,IF QUOTED,WEEK-DAYS, NORMAL BUSINESS HOURS SUBMITfED BY: ,11M CLEARY SUBTOTAL $42,542.00 DELIVERY TIME F.O.B.POINT PAYMENT TERMS 3-4 Weeks ARO PALM DESERT NET 30 DAYS Acceptance of Proposal: The above pricing,speafications, SIGNATURE: terms and conditions are satisfadory and are hereby accepted. You are authorized to do the work as ouUined above. DATE: 96 L NU M , A 17 9 0-7114 629- 325 S. 3RD ST. SUITE 1-171, LAS VEGAS, NV 89101 (800)998-1974 FAX:(702) 382-7404 A��`„� Proposal - Page 2 A/R CLEANING SYSTEMS California License#772590;Nevada License#56619 Specializing in lndustria/Ventilation and C/ean Air Solutrons TO: CITY OF PALM DESERT LOCATION: 73510 FRED WARING DR RIVERSIDE COUNTY STATION#33 PALM DESERT CA 92260 ATTN: Steve Aryan APPLICATION: VEHICLE EXHAUST PHONE NO. FAX NO. PROPOSAL DATE EXPIRATION DATE PROPOSAL NO. 760-340-1120 760-863-7072 Februa 6, 2008 J06 -16154 SUBTOTAL FROM PAGE ONE: $42,542.0 QTY ITEM NO. DESCRIPTION UNIT PRICE AMOUNT 1 TAX SALES 7AX @ 7.75% 3,297.00 3,297.00 1 INSTALL COMPLETE TURN-KEY INSTALLATION ESTIMATE of the PLYMOVENT Diesel Exhaust 31,950.00 31,950.00 ESTIMATE Capture System specified in this proposal. Includes electrical hook up to adequate P.O.C., ducting,supports, misc. hardware, lift and labor @ prevailing rates.Tail pipe modification required to accommodate the system is the responsibility of others. Permits can be provided at costs plus$85 per hour labor if required. Any modification to the above proposal as required by municipality will be at an additional charge.Outside services such as engineered drawings or structural engineering fees will be passed on at cost. Includes silencer on blower. 1 FREIGHT TRANSPORTATION CHARGE ESTIMATE T,500.00 1,500.00 TWO YEAR FACTORY WARRANTY Electrical or pneumatic connection,hook-ups,or fire suppression, BY OTHERS PERMITS required to install or operate,or anv concrete aad are responsibility of BUYER INSTALLATION,IF QUOTED,WEEK-DAYS, NORMAL BUSINESS HOURS SUBMITfED BY: ��M CLEARY TOTAL �79,ZH9.00 DELIVERY TIME F.O.B.POINT PAYMENT TERMS 3-4 Weeks ARO PALM DESERT NET 30 DAYS Acoeptance of Proposal: The above pridng,specifications, SIGNATURE: tertns and conditions are satisfaciory and are hereby accepted. You are auUwrized to do the work as ouUined above. DATE: 196 . H A, 17 90 0-71 4 FA : 909) 9-3 325 S. 3RD ST. SUITE 1-171, LAS VEGAS, NV 89101 (800)998-1974 FAX:(702) 382-7404 A���J Proposal A/R CLEANING SYSTEMS California License# 772590; Nevada License#56619 Specializing rn lndustrra/Ventilation and Clean Air Solutions TO: RIVERSIDE COUNTY FIRE DEPT. LOCATION: 73510 FRED WARING DR STATION#67 PALM DESERT CA 92260 ATTN: Steve Aryan APPLICATION: VEHICLE EXHAUST 60-340-N1O20 I 7 0-863 7072 I P ebruOSAs DA�$E I EXPIRATION DATE I PROP�OSA 6 NO. QTY ITEM NO. DESCRIPTION UNIT PRICE AMOUNT 2 SBTA 31-D PLYMOVENT SBTA-31-D Sliding Balancer Track(Sgl.Track, 1 Vehicle); includes(1)20'8(1) 2,462.00 4,924.00 9.5'box-lock track&splicer plate per vehicle,with 25'of 4°diameter yellow 8�black hose,saddle, trolley/balancer,endstop w/security bolts, riser bracket, uncoupling valve assembly,6.25" "GRABBER"Nozzle,Swivel Safety Disconnect, Manual fill Valve, and complete pneumatic circuit for passive release. Also includes all necessary support legs, side braces and brackets. 1 TEV 3110�0 PLYMOVENT TEV-3110-60 3 hp,three phase Radial Exhaust Fan rated @ 1500 CFM @ 6"w.g. 1,342.00 1,342.00 3805-A081 at 3450 rpm, 208v/220v/440 v 3PH 60HZ,9 amp. 1 OS-3 706037 PLYMOVENT OS-3 CONTROL OPERATION SYSTEM FOR-3HP,3 phase 721.00 721.00 1 MATERIALS MISC. MATERIALS TO COMPLETE THE INSTALLATION INCLUDING DUCTING AND 1,500.00 1,500.00 FITTINGS 1 TAX SALES TAX @ 7.75% 657.74 657.74 1 INSTALL INSTALLATION COMPLETE, including electrical hook up&connection to adequate POC, all 16,800.00 16,800.00 ducting,supports, misc. hardware, lift and labor at PREVAILING rates.Tail pipe modification is the responsibility of others. Any modification to the above proposal as required by municipality will be at an additional charge.Outside services such as engineered drawings or structural engineering fees and related costs are not included 8�will be passed on at cost. Electrical or pneumatic connection,hook-ups,or fire suppression,BY OTHERS PERMITS required to install or operate,or anv concrete oad are responsibility of BUYER INSTALLATION,IF QUOTED,WEEK-DAYS, NORMAL BUSINESS HOURS SUBMITfED BY: JIM CLEARY TOTAL $25,944.74 DELIVERY TIME F.O.B.POINT PAYMENT TERMS 3-4 Weeks ARO JOB SITE 50%with P.O. BALANCE DUE UPON DELIVERY/INSTALLATION OF EQUIPMENT Acceptanoe of Proposal: The above pricing,speafications, SIGNATURE: terms and conditions are satisfadory and are hereby acoepted. You are authorized to do the work as ouUined above. DATE: 96 . L E P NA, A 91768 ( 9) -7114 AX: 9) -323 325 S. 3RD ST. SUITE 1-171, LAS VEGAS, NV 89101 (800) 998-1974 FAX:(702) 382-7404 A���� Proposal A/R CLEANING SYSTEMS California License#772590; Nevada License#56619 Specializing in/ndustria/Ventrlation and C/ean Air Solutions TO: RIVERSIDE COUNTY FIRE DEPT. LOCATION: 73510 FRED WARING DR STATION#71 PALM DESERT CA 92260 ATTN: Steve Aryan APPLICATION: VEHICLE EXHAUST 60-340-N1O20 I 760-863 7072 I P ebruOaryA6,2 08E I EXPIRATION DATE I PROP�OSA 6 NO. QTY ITEM NO. DESCRIPTION UNIT PRICE AMOUNT 4 SBTA 21-B PLYMOVENT SBTA-21-B Sliding Balancer Track(Sgl.Track, 1 Vehicle); inGudes(1)20'track 2,362.00 9,448.00 per vehicle,with 25'of 4"diameter yellow&black hose, saddle,trolley/balancer,endstop w/ security bolts, riser bracket, uncoupling valve assembly,6.25""GRABBER° Noule, Swivel Safety Disconnect, Manual fill Valve, and complete pneumatic circuit for passive release. Also includes all necessary support legs,side braces and brackets. 1 TEV 559-60 PLYMOVENT 5 hp TEV fan,three phase Radial Exhaust Fan rated @ 2500 CFM @ 7"w.g.at 1,389.00 1,389.00 3450 rpm. 1 OS-3 706037 PLYMOVENT OS-3 CONTROL OPERATION SYSTEM FOR-3HP,3 phase 721.00 721.00 1 MATERIALS MISC. MATERIALS TO COMPLETE THE INSTALLATION INCLUDING DUCTING AND 2,000.00 2,000.00 FITTINGS 1 7AX SALES TAX @ 7.75% 1,050.74 1,050.74 1 INSTALL INSTALLATION COMPLETE, includinq electrical hook up&connection to adequate POC,all 20,955.00 20,955.00 ducting,supports, misc. hardware, lift and labor at PREVAILING rates.Tail pipe modification is the responsibility of others. Any modification to the above proposal as required by municipality will be at an additional charge.Outside services such as engineered drawings or structural engineering fees or any related costs will be passed on at cost. Electrical or pneumatic connection,hook-ups,or fire suDPression.BY OTHERS PERMITS required to install or operate,or anv concrete oad are responsibility of BUYER INSTALLATION,IF QUOTED,WEEK-DAYS, NORMAL BUSINESS HOURS SUBMITfED BY: JIM CLEARY TOTAL $35,563.74 DELIVERY TIME F.O.B.POINT PAYMENT TERMS 3-4 Weeks ARO JOB SITE NET 30 DAYS Acceptance of Proposal: The above pricing,speafications, SIGNATURE: tenns and conditions are satisfadory and are hereby accepted. You are authorized to do the work as outlined above. DATE: 19 . H AV N NA, A 917 (9 20-71 4 FA : 09) -323 325 S. 3RD ST. SUITE 1-171, LAS VEGAS, NV 89101 (800)998-1974 FAX:(702) 382-7404 Product description The STR system consists of a special and easilyvisable Upon an alarm call the hose assembly and the crab extraction hose assembly with a unique pneumatic move along with the vehicle,the crab striking a trip piate exhaust connection called the PlymoVent Grabber�.This immediately reteases the air pressure in the Grabber6', resembles a glove which,when filled with air, makes a resufting in a disconnection of the Grabber�"at the exit. total seal around the exhaust pipe.The extraction hose The crab hits the hydralic shock absorber,faking up the has an inbuilt safety disconnect coupling and a manual kinetic energyfrom the crab and the hose assembiy.On fill deflation valve. It is suspended on a balancer block, the return of the vehicle to the station,the Grabber�'is safety hung from on a special crab, running inside the connected to the exhaust pipe and activated by simply aluminium profile mounted above and to the side of the pressing the MFD valve as the vehicle backs through the vehicle.The aluminium profile has a circular design with gate.At the same time the fan automatically starts and an open square area of 31 sq.inch.The open underside of the vehicle continues to its rest position. the profile is sealed by rubber lips. Side view HydrallcShock Profile S Absorber $�Q��/IeW CRP�B with Hose Assemby 5ft � � � 0 � � . GRAE�ER° Over view Double vehicle application,side view �;:.,.d,:::.,.,:::�;,,��,�,,.��-�" - -.-,...�.:,.:�.:,:..y:�...�. �._. , ..... � _ _ __ _ — -�-j°�-,.�.�r`I � --- -- -- 1.6ft Advantages •The system will allow up to four vehicles to stand •Unique pneumatic exhaust pipe connector"GRABBER�"; in-line. for different sizes of exhaust pipes. 100%tight against •Adjustable release points. dieselexhaustfumeleaksonstart-up. •The system can be extended up to 100.ft. •Safety disconnect coupling;fail safe system,easily recon- •Adjustable mounting supports. nectable. •Gas-tight rubber seals. •Hydraulic shock absorber to take up kinetic energy from the travelling crab assembly. STR/USA/3/34 Product Descript�on The SBT system consists of a special and easily visable The underside ope�area is used for positioning the end - extraction hose assembly with a unique pneumalic stops and for the slidir�g ihe irdley.Up�n an atarm call exhaust connection called the PlymoVent Grabber�.This ihe hose assembly ar�d ttre trobey move�ong with the resembles a glove which,when filled wiTh compressed air, vehide,the trolley slides under a release valve makes a total seal around the exhaust pipe. immediately releases the air pressure in fhe Grabber�. The extraction hose has an inbuilt safety disconnect The trolley travels to the rubber shodc absorber at the exit coupling and a Manuai Filt Deflation Valve.it is end,takir�g e�p the Idnetic snergy from the troUey arxi the suspended on a balancer block,safery hole hang from a hose assembly.On the�ehim of the vehide to ihe station, special trolley,n�n�ing inside an aluminium profile above the Grabber•is oannecked to�e exhaust pipe and and to the side of ihe vehide. activiated by simply pnessing the MFD valve as�e The aluminium profile,track,is designed io the three(3) vehide badcs ihrough ti�e gate.At U�e s�ne tirne the fan section principle of which two(2)sections have open aut�ornatic�ally starts up and ihe vetiide oon6nues to its areas,one on the underside and one on the overside.The rest position. ove►-side open area is used for positioning the support legs,dud and exhaust hose connedor and the release valve. Side view End view � � � � /� / � � /�' � / ' � ____; � � __ DucU S----� � 0,5 m i �. =• 11 Tradc ���� 2,0 m � � � ' Trose Release valve � E � End stop wifh � ; -_ -- —'}G( nibber shodc�sorber � , E � �� o : � O D ; _ o E - � � o ; -- :.� �, o00 ; ; o i � .O � Grabber' t 9 11 111 + O " o 0 � i ; ,. / /,%�T/�%////%l/ . , . ,. . � Overview Track section � � _ Support sectian _1J �� - --=J p � � � L---- -� � Stab1¢or sedion � O 0,5 m � Trdl sedion Advantages —' �-� •Ah�miniurn prof[tes;klght and stror�g "GRABBER'";to suit different s"rzes of exhaust pipe. •End stops with rubber shodc absorbers;to take up 100%light against�iesel exl�aust iume leaks on kinetic energy from tt�e trdleys. startup. •Adj�table�elease points depending on fhe speed of •Satety disoonned coup6ng;Fail safe system,easily the ealt--out vef►ide. reoonnec�abte. •Pre-fitted extraction hose with eas�y seen biadclyetbw •Automatic staR-stop af fan by exh�lst gas start�p markings. detector.Reduoes electric oosts ir�instaqatior�whist •Unique pneumatic exhaust pipe oonnec�or c",�rt"ng tt10%security that farts start or stop when -- �etuctes start oc sbp. SBTIEfiglSvPJ3/39 RIVERSIDE COUNTY . FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West San Jacinto Avenue • Perris,California 92570 • (909)940-6900 • Fax(909)940-6910 John R.Hawkins Fire Chief Yroudly serving the To: Steve Aryan Date: February 8, 2008 unincorporated Facilities Management areas of�Riverside County and the City of Palm Desert Cities of: From: Tony Fox,Captain Banning CAL FIRE/Riverside County Fire Department t3caumont Strategic Planning Division .� Calimesa Subject: P1ymoVent Exhaust Systems :• Canyon Lake . P1ymoVent is unique from competitor systems as they provide a pneumatic collar Coachella attaching to the apparatus thus capturing 99.9% of source exhaust. I)esert liot Springs . The pneumatic collar requires retrofit to apparatus and Riverside County Fire Indian Wclls Department apparatus are specifically designed for the P1ymoVent Exhaust Indio System resulting in compatibility and fleet standardization. Other brands will : include additional retrofitting of apparatus or facilities resulting in additional Lake Elsinore COStS. I.a Quinta . P1ymoVent was chosen due to its efficient source capture and its compatibility Vloreno Valley rvith other departments systems in use such as Cathedral City and Palm Springs. Palm Descrt When Mutual Aid coverage is needed or provided between jurisdictions such as a •:• Palm Springs or Riverside County Fire Department Engine Company's, the Perris system and design features are compatible for use in each others location. :• Rancho Viirage :• Other systems again witl require retrofitting or be considered "unusable" creating San Jacinto contamination factors. Temccula P1ymoVent is the standard for Riverside County Fire Department stations and apparatus. Aoard of Supervisors I3ob Buster, TON fOX Uistrict 1 y Captain-Strategic Planning Division John Tavaglione, �;St�;�t 2 Riverside County Fire Department Jett'Stone, llistrict 3 Roy Wilson, District 4 Marion Ashley, District 5