HomeMy WebLinkAbout0306 - Single Curb RampSINGLE RAMP
RADIUS < 35
WHEN SIDEWALK IS AT
THE RIGHT—OF—WAY
OR WHEN MEANDERING
LS
I:l
CURB AND GUTTER DETAILS
PER STD. NO. 403
6.5' TO CF
4' MIN. LANDING
WINGS SHALL NOT EXCEED 10% II
a
CROSSWALK
45°
RAMP CONSTRUCTION SHALL
INCLUDE CURB AND GUTTER AND
SIDEWALK FROM BCR TO ECR
4' Y (SEE TABLE BELOW)* 4' MIN.
22' 3'
MAX. DETECTABLE TOP OF
FLUSH
WARNING RAMP ROUNDED
(SEE NOTE 1)
%2 PVMT------------
5%5%�
COLD JOINT
SECTION A -A
Y-- CURB FACE (FT)
6.33%
TABLE Y
CF
Y*
6"
7.90'
g"
10.53
NOTES:
1. TRANSITIONS FROM RAMPS TO WALKS, GUTTERS, OR STREETS SHALL BE FLUSH AND FREE
OF ABRUPT CHANGES.
2. TRUNCATED DOMES SHALL BE CAST —IN —PLACE, REPLACEABLE, FEDERAL YELLOW IN COLOR.
** 'Y' SHALL NOT EXCEED 10.53', UNLESS APPROVED BY THE CITY ENGINEER N.T.S.
CITY OF PALM DESERT APPROVED BY:
DEPARTMENT OF PUBLIC WORKS STD NO.
�✓��,A�� Feb 19, 2025
SINGLE CURB RAMP 306
MARTIN ALVAREZ DATE
PUBLIC WORKS DIRECTOR