HomeMy WebLinkAbout0306 - Single Curb RampSINGLE RAMP RADIUS < 35 WHEN SIDEWALK IS AT THE RIGHT—OF—WAY OR WHEN MEANDERING LS I:l CURB AND GUTTER DETAILS PER STD. NO. 403 6.5' TO CF 4' MIN. LANDING WINGS SHALL NOT EXCEED 10% II a CROSSWALK 45° RAMP CONSTRUCTION SHALL INCLUDE CURB AND GUTTER AND SIDEWALK FROM BCR TO ECR 4' Y (SEE TABLE BELOW)* 4' MIN. 22' 3' MAX. DETECTABLE TOP OF FLUSH WARNING RAMP ROUNDED (SEE NOTE 1) %2 PVMT------------ 5%5%� COLD JOINT SECTION A -A Y-- CURB FACE (FT) 6.33% TABLE Y CF Y* 6" 7.90' g" 10.53 NOTES: 1. TRANSITIONS FROM RAMPS TO WALKS, GUTTERS, OR STREETS SHALL BE FLUSH AND FREE OF ABRUPT CHANGES. 2. TRUNCATED DOMES SHALL BE CAST —IN —PLACE, REPLACEABLE, FEDERAL YELLOW IN COLOR. ** 'Y' SHALL NOT EXCEED 10.53', UNLESS APPROVED BY THE CITY ENGINEER N.T.S. CITY OF PALM DESERT APPROVED BY: DEPARTMENT OF PUBLIC WORKS STD NO. �✓��,A�� Feb 19, 2025 SINGLE CURB RAMP 306 MARTIN ALVAREZ DATE PUBLIC WORKS DIRECTOR