Loading...
HomeMy WebLinkAbout0501 - Under Sidewalk Drain (Cast in Place)JOIN TO ONSITE DRAINAGE R/W N SEE NOTE 1 9i w 0 w 0 A ---r-FLOW LINE -----r-FLOW LINE 1/4" CHECKERED PLATE SLLIP RESISTANT 1.5% (2.00% MAX AS -BUILT) 2% MIN �y OUTLET BOX-/ L� A DRAIN OUTLET BEND END OF PLATE TO MATCH CURB FACE Wal D � V SECTION "A —A" SEE NOTE SEE NOTE 3" STUD ANCHOR 14" 0( TYf DETAIL "A" CURB & GUTTER SEE DETAIL "A" SLIP RESISTANT 1/4" CHECKERED PLATE D p ° SEE NOTE 2 6" 12" TO 36" 6" /i �JJJJ'; NOTES: SECTION " B—B" 1. UNDER SIDEWALK DRAIN TO BE CONSTRUCTED PERPENDICULAR (90') TO THE CURB ALIGNMENT. VARIATIONS FROM 90' REQUIRE THE APPROVAL OF THE CITY ENGINEER. 2. SLOPE TO DRAIN TO ONE SIDE. 3. ALL EXPOSED METAL PARTS TO BE HOT -DIP GALVANIZED AFTER FABRICATION. 4. 1 1 /2" X 1 1 /2" X 1 /4" "L" FRAME WITH 3/8" X 1 /4" STEEL STRIP WELDED TO FRAME. 5. CHECKERED PLATE SHALL BE SLIP RESISTANT HOT -DIP GALVANIZED STEEL MAXIMUM WIDTH 36". 6. FASTEN WITH 1/4" COARSE -THREAD COUNTERSINK STAINLESS STEEL SCREWS AT 12' OC. 7. WHEN ABUTTING SOIL HAS A HIGH SULFATE CONTENT, USE A MODIFIED CONCRETE MIX AND PLACE 6" MIN CLASS 2 AGGREGATE BASE AND 6 MIL. PLASTIC SHEETING UNDER AND AROUND ALL SIDES OF CONCRETE IMPROVEMENTS. FOR EXPANSIVE SOIL, PLACE 6" MIN CLASS 2 AGGREGATE BASE UNDER CONCRETE IMPROVEMENTS AS DIRECTED BY THE ENGINEER. 8. CONCRETE MINIMUM CEMENTITIOUS MATERIAL CONTENT=505LB/CU YD. 9. NOT FOR USE IN PUBLIC RIGHT-OF-WAY. N.T.S. CITY OF PALM DESERT APPROVED BY: DEPARTMENT OF PUBLIC WORKS STD NO. Feb 19, 2025 UNDER SIDEWALKDRAIN 501 MARTIN ALVAREZ DATE CAST IN PLACE PUBLIC WORKS DIRECTOR