HomeMy WebLinkAbout0507 - Standard Drywell DetailE.O.R. SHALL SPECIFY SOLID OR GRATED LID. 24"� C.I. GRATE &FRAME ALHAMBRA FOUNDRY A-1200 OR NOTE: \ ALL JOINTS ABOVE THE LEACHING AREA SHALL BE MORTAR SEALED INSIDE AND OUT. ........... N z `J� =11 00 12» =11 0o III o° M to �c =� IIII�IIII� ��� �1 CITY OF PALM DESERT APPROVED BY: APPROVED EQUAL. ADAPT AS REQUIRED FOR V-GUTTER & CURB AND GUTTER INSTALLATION. SET RIM TO GRADE WITH PRECAST RISERS. INVERT OF INLET PIPE SHALL BE MIN. 6" HIGHER THAN TOP OF DOWN DRAIN. COMPACT BACKFILL TO 90% MIN. WITH TOP 12" COMPACTED TO 95%. FLOODING & JETTING WILL NOT BE ALLOWED. wl 1OR A.B.S. INSTALL ATRIUM 4" CONCRETE SLAB (POURED IN PLACE) SHALL EXTEND 6" INTO UNDISTURBED SOIL PRE -CAST CONCRETE SLAB. 48" � MIN. PRE -CAST PERFORATED CONCRETE RING. ----3/8" TO 3/4" WASHED ROCK. �-_IROCK 3/8" TO 3/4" WASHED ON UNDISTURBED SOIL. i NON -WOVEN FILTER FABRIC PER CALTRANS STD. SPEC. 88-1.03 BETWEEN THE WASHED ROCK AND UNDISTURBED SOIL N.T.S. DEPARTMENT OF PUBLIC WORKS STD NO. Feb 19, 2025 STANDARD DRYWELL 507 MARTIN ALVAREZ DATE DETAIL PUBLIC WORKS DIRECTOR