Loading...
HomeMy WebLinkAboutResidential HVAC Virtual Inspection ChecklistResidential HVAC Virtual Inspection Checklist | City of Palm Desert Skip to main content City of Palm Desert Building and Safety Division 73510 Fred Waring Dr, Palm Desert, CA 92260 Phone: tel:+17607766435(760) 776-6435 | Email: mailto:permitcenter@cityofpalmdesert.orgpermitcenter@cityofpalmdesert.org Website: https://www.palmdesert.govCity of Palm Desert official website Residential HVAC Virtual Inspection Checklist Purpose and Applicability This checklist is intended for virtual HVAC replacement inspections and does not apply to new construction or new HVAC locations (subject to approval). This form must be completed and submitted with the required photos. See the step-by-step instructions on how to submit pictures. Required Photos and Documentation Please provide 7–8 photos total that include the following: Photo of the Residence Address must be clearly visible. One to Two Photos of the Overall Equipment (Service Side) Include in these photos: Refrigerant line-sets with insulation and suction port locks. Gas line sediment trap with fuel gas shut-off valve. Condensate water line and termination point. Vent connections, chimney/B-vent. Support/anchorage method (attic, pad, roof platform, etc.) per CMC §303.4. Exterior units only: Show UV protection on exposed line-set insulation. Manufacturer’s Label Must show required fuse or breaker size. Overcurrent Protection Photo of installed fuse (if used). Photo of circuit breaker supplying the equipment (must be labeled per CEC §408.4). Electrical Disconnect Provide a photo showing an electrical disconnect within sight of the unit. Disconnect must be readily accessible and labeled (CEC §440.14). Combustion Air Vents Required only if FAU is located in a closet or enclosed space (not required for garage installation). Condensate Overflow Protection (If Applicable) If equipment is located above a finished ceiling (e.g., in an attic), provide a photo showing: Secondary drain pan, or Float safety switch installed on primary drain line. Project Status Documentation Include a copy of the completed Project Status Report page. Smoke/Carbon Declaration Form Provide completed City’s Smoke/Carbon Declaration form only (do not include photos). (CRC Sections R314 & R315) Applicant Affirmation I affirm that the above information and submitted photographs accurately represent the completed residential HVAC installation. During the review of the submitted photographs, the inspector may require a video, virtual, or in-person inspection. The inspector will provide further instructions, if necessary. Applicant Signature: Date: Project Address: Permit Number: City of Palm Desert Building and Safety Division. This document is formatted for public-facing web access, screen-reader compatibility, keyboard navigation, and printing. Print Download HTML blob url