HomeMy WebLinkAboutResidential Addition Combined Final
Rev: (Date/Initials)
Page 1 of 5
CITY OF PALM DESERT
Building and Safety Division
73510 Fred Waring Dr, Palm Desert, CA 92260
Phone (760)776-6435 ▪ Email permitcenter@cityofpalmdesert.org
Website: https://www.palmdesert.gov
RESIDENTIAL ADDITION-ALTERATION-REMODEL-REPAIR
PLAN REVIEW SUBMITTAL CHECKLIST
#BLDG-CKL-23-0003
As of January 1, 2022, Building and Safety permits require digital submissions of construction plans
and documents. Digital submission can be completed at: www.pdpermits.com
For permit fees, questions, or estimates please email: permitcenter@cityofpalmdesert.org
Applicants shall follow the City’s Electronic Construction Plan Format and Online Submittal Bulletin
when creating or drafting the project. The bulletin is available: Here
MINIMUM SUBMITTAL REQUIREMENTS:
The construction plans shall include the following, when applicable, or required by the plan review
team. Missing any items below may result in the submittal being rejected:
- Completed Building Permit Application
- California Energy and Green Building Documentation
- Title Sheet (REQUIRED
- Site Plan - The items below must be clearly shown on the Site plan
o Must be drawn in black and white only
o North Arrow
o Scale
o Dimenesions
o Property lines
o Adjacent streets
o New and Existing structures must be clearly labeled
- Precise Grading Plan (Only needed for Additions over 1,000 sq. ft. (If applicable)
- Floor Plan
- Roof Plan
- Exterior Elevations and Building Sections
- Architectural Details
- Electrical Plans
- Mechanical Plans
- Plumbing Plans
- Structural plans and calculations
Rev: (Date/Initials)
Page 2 of 5
Required calculations shall include but not be limited to:
• Structural design for both all vertical and lateral load-resisting elements (if not conventional).
• Truss calculations and details (signed by the engineer) shall be approved for conformance by the
project’s licensed design professional. These may be deferred.
SUMMARY OF REQUIRMENTS
The following summary is a general guide when creating a plan set for a residential alteration-addition-
remodel-repair for the City of Palm Desert. This checklist serves as the minimum information for the initial
plan review. Additional or supplemental information may be required during the review process.
• Title Sheet/Cover Sheet
- The owner's name, address, and telephone number(s).
- A legal description and address, lot/tract name-number, and assessor parcel number.
- A detailed Scope of Work that includes all construction, additions, alterations, and repairs cited on
the Building Permit Application.
- Occupancy classification, type of construction, and zoning.
- Fire sprinklers.
- Area tabulations of habitable square feet, covered patio areas, garage, and mechanical areas.
- A complete Sheet Index or Table of Contents.
- A vicinity map with a North arrow covering at least a two-block area locating the project.
Incorporated onto the first sheet of project plans (Copy and Paste):
2022 California Building Code (CBC)
2022 California Residential Code (CRC)
2022 California Electrical Code (CEC)
2022 California Mechanical Code (CMC)
2022 California Plumbing Code (CPC)
2022 California Energy Code (CEC)
2022 California Green Building Standards Code (CGBC)
Palm Desert Municipal Code
Incorporated onto the first sheet of project plans (Copy and Paste):
Palm Desert Municipal Code requirements:
A. Approved temporary sanitary facilities are required (H&S 5416)
B. Contractor and/or owner shall provide a trash bin (PDMC 8.16)
C. Building Materials or Debris Storage shall be on the property of the permit. (PDMC 8.70)
D. The public right-of-way shall always be maintained in a clean condition. (PDMC 8.20)
E. Address numerals shall comply with PDMC 15.28.
F. Construction Hours (PDMC 9.24):
OCTOBER 1st THRU APRIL 30th MAY 1st THRU SEPTEMBER 30th
Rev: (Date/Initials)
Page 3 of 5
Monday – Friday: 7:00 a.m. - 5:30 p.m. Monday – Friday: 5:30 a.m. - 7:00 p.m.
Saturday - 8:00 a.m. - 5:00 p.m. Saturday 8:00 a.m. - 5:00 p.m.
Sunday - NOT ALLOWED Sunday - NOT ALLOWED
Government Code Holidays - NOT ALLOWED
**Violation of the above work hours is a citable offense under PDMC 9.24.070.
• Site Plan
- All existing and proposed structures, including all garden and retaining walls. Indicate all required
setback distances.
- The location and sizes of all existing and proposed utilities (sewer, gas and electricity).
- The elevations of the building site and surrounding area(s). Indicate site drainage and direction of
flow.
- All property lines, easements, and rights of way.
- North arrow.
• Demolition Plan
- Provide a demolition plan identifying areas, walls, and roof structures bring removed. Do not overlay
the demolition plan onto the proposed Floor Plan.
• Floor Plan
- Provide a fully dimensioned or scaled Floor Plan identifying and labeling all rooms and areas.
- Demonstrate existing areas and areas to be remodeled
- Demonstrate and identify interior components, fixed appliances, and
- Provide a wall legend identifying nominal wall size, R-value of insulation, and any fire separation
requirements.
- Provide a Door and Window Schedule with U-factor/SHGC information.
- Identify utility meter(s) at the building.
• Roof Plan
- Provide a Roof Plan that identifies the roofing materials, roof slope, drainage, and required attic
ventilation.
- Include, when necessary, the attic ventilation calculations, radiant barrier requirements, and roof
drain sizing calculations.
- Identify solar ready areas.
• Exterior Elevation(s)
- Show the architectural orientations of each direction. Please include building height measurements.
- Exterior wall finishes.
- Roof slope and type of covering.
- Window and door location and types to coincide with the floor plan.
• Section Plan(s)
- Show the section architectural, fire, life-safety, and energy com ponents of the building’s envelope.
- Please include building height measurements.
Rev: (Date/Initials)
Page 4 of 5
• Architectural Details
- Show details and enlargements of different architectural components of the building (i.e.
window and door moldings, flashing installation dim ensions, fireplace and hearth specifications,
stairway and handrail construction, etc....).
- Manufacturer Specifications and Evaluation reports (ICC-ESR).
• Electrical, Mechanical, and Plumbing:
- Show all proposed electrical, mechanical, and plumbing design, including but limited to:
Electrical:
Identify and provide the location of all services and subpanels within the project.
Provide a complete electrical plan outlining service, feeder, and branch layout.
Include all receptacles and fixtures layouts.
Identify branch circuit protection.
Load calculations and a single-line diagram are required.
Mechanical:
Provide a complete plan identifying new equipment and ducting including sizes.
Identifying supply and return air registers.
Provide any combustion and/or make-up air requirements.
Identify and supply new equipment specifications.
Plumbing:
Provide a complete building drain isometric layout (including sizes).
Provide a complete fuel gas isometric layout (including calculations and sizes).
Provide BTUs and Total Developed Lengths at each natural gas fixture.
Provide a complete domestic water layout (including sizes).
• Structural Plans and Calculations
- Complete geotechnical and soil reports and evaluations, when applicable. Consult with the City’s
Land Development Division.
- Foundation and Framing Plan
Provide the layout of the foundation and dimensions, footing sizes, columns, hold -downs, anchor
bolt sizes, and spacing. Demonstrate the construction of the braced wall, shear wall, and roof
framing. Including, but limited to, all beams, joists, rafters, etc. Based on the design, justification is
necessary for all components.
- Structural Details:
Provide details and enlargements of different components of the building s tructure, i.e., framing
details, foundation details, etc.
Important Note: If the proposed construction conforms to conventional construction parameters of the
California Residential Code, structural calculations, and the involvement of a designed professional (Licensed
Rev: (Date/Initials)
Page 5 of 5
Architect and/or Engineer) may not be required. However, be advised that the conventional construction
requirements contained within the California Residential Code are complex and require an individual who is
experienced and knowledgeable in basic engineering principles to design a compliant structure. Unless the
designer is well acquainted with the complexities of the code, we recommend that an experienced design
professional be consulted.
• California Green Building Requirements
When an addition, alteration, or both increase the building’s conditioned area, volume, or size, all the
mandatory measures of Chapter 4 shall be applied. Plans shall indicate the method of verification of
compliance with all applicable CALGreen requirements.
Residential Mandatory Measures and a Construction Waste Management Plan can be found on the City
website: Green Building.
• California Residential Energy Requirements
The City of Palm Desert is within Climate Zone 15. Provide the required CF-1R forms that correspond to
your project. For more help with forms, compliance manuals, and information please see Energy Code Ace
at http://energycodeace.com/
Other Departments or Agencies:
• Planning Department for approval of zoning, lot coverage, set-backs, height, and building design
requirements may be in conjunction with your plan submittal to the Building Department. Please
coordinate directly with the Planning Department at (760) 776-6483
• Land Development Division for grading permit that may be required given the size and scope of the
project. Please coordinate directly at (760) 776-6483.
• Riverside County Fire Marshall’s at (760) 863-8886 or https://rctlma.org/plus-online for questions on fire
sprinklers.
• All contractors and sub-contractors must have a current City of Palm Desert Business License before
permit issuance per Palm Desert Municipal Code, Title 5. A complete and approved sub-contractor list
must be submitted to schedule a final inspection. Allow 5-7 business days for the business license to
process the list. Contact Business Licensing at (442) 325-3954 for applications or Building and Safety
at (760) 776-6420 for subcontractor lists.
Sample Residential Site Plan for Addition
---------------------------------------------------�-----------
Public Use Easement (PUE)
Existing Pool o Pr posed 5
1 Shed
--------------------- L----------
I
Proposed
se Patio I
m a
OJ
a`
Existing Dwelling
1,500 sf W
WW
F
Proposed ; 5ft�
isting Addition
rage 180 sf
x 20'
T
Overhang (8")
Driveway o Existing
Landscaping
1
Right of Way
STREET NAME
1. Property Owner Name
2. Property Address
3. Assessor's Parcel Number
4. Scope of Work
►/
Scale 1' = 10"
(Example not to scale)